3µm Fortis C18. Fortis 2.1µm. Increased Efficiency. Scalability and Sensitivity

Similar documents
Strength in Technology

1.7µm Fortis UHPLC Columns

1.7µm Fortis C18 UHPLC Columns

1.7 m Fortis UHPLC Columns

ACE. For increased polar retention and alternative selectivity. Alternative selectivity for method development

penta-hilic UHPLC COLUMNS

Applications. Column Reproducibility. Casein Tryptic Digest. QC Test. Antimalarial. Antipsychotic. Column Reproducibility 7

penta-hilic UHPLC COLUMNS

Basic Principles for Purification Using Supercritical Fluid Chromatography

Alltech Alltima HP Introduction

High Speed vs. High Resolution Analyses in HPLC: A Critical Performance Comparison of Column Options Using Poppe and Kinetic Plots

How proteins separate on reverse-phase HPLC

Reversed Phase Solvents

Put the. C18 aside. and take a look... Reasons. to try the. NEW Gemini C6-Phenyl

ACE SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability

LC Technical Information

Kromasil Eternity Designed for long life

UPLC Method Development and Validation

Product Bulletin. ACE LC/MS and Rapid Analysis HPLC Columns. HPLC Columns

ACE Excel SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability

ultimate efficiency unleashed [ Cortecs 1.6 µm columns ]

LC and LC/MS Column Selection Flow Chart

ACE C18-PFP. Hydrophobic and pentafluorophenyl mixed mode interaction. High efficiency 2µm, 3µm, 5µm and 10µm particles for UHPLC and HPLC

ACE SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability

STUDY OF LOADABILITY AND SELECTIVITY OF PHARMACEUTICAL COMPOUNDS ON RPLC COLUMNS

Improve Peak Shape and Productivity in HPLC Analysis of Pharmaceutical Compounds with Eclipse Plus C8 Columns Application

Kromasil Eternity Designed for long life. For use in HPLC and UHPLC

viridis Columns Bringing a New Dimension to SFC Combining state-of-the-art media manufacturing with industry leading column technology, Viridis

Developing a fast, generic method for rapid resolution LC with quadrupole MS detection. Application Note

Agilent 1290 Infinity Quaternary LC Stepwise Transfer to Methods with MS-Compatible Mobile Phases

KromasilSFC. Designed for green technology. Introducing Kromasil SFC XT

Chiral separations efficient, fast and productive

LIQUID CHROMATOGRAPHY

Thermo Scientific Accucore XL HPLC Columns. Technical Manual

Advanced HPLC Method Development Using Quality by Design

The Theory of HPLC. Ion Pair Chromatography

LC-MS/MS Method for the Determination of Diclofenac in Human Plasma

HICHROM. Chromatography Columns and Supplies. LC COLUMNS HALO and HALO-5. Catalogue 9. Hichrom Limited

Trends in Method Development for HPLC and UHPLC... the movement toward using solid-core particles

ACE Ultra Inert Base Deactivated HPLC Columns

Acclaim Mixed-Mode WCX-1

Orosil HPLC Columns. OroSil HPLC columns are designed for the separation of polar, semi-polar, and nonpolar compounds at low to medium ph.

The Secrets of Rapid HPLC Method Development. Choosing Columns for Rapid Method Development and Short Analysis Times

HPLC Preparative Scaleup of Calcium Channel Blocker Pharmaceuticals Application

Optimisil HPLC & UPLC Column catalogue

Fast Screening Methods for Steroids by HPLC with Agilent Poroshell 120 Columns

ProntoSIL C18-EPS Reversed-Phase HPLC Columns

BETASIL Columns TG Å high purity silica

Kromasil. for your analytical HPLC. Kromasil. The way to peak performance in liquid chromatography

General Principles of HPLC Method Development

Basic chromatographic parameters and optimization in LC

Hypersil BDS Columns TG 01-05

FluoroPhenyl. Stationary Phase: Get the Power of HILIC and RP Modes in One LC Column. Pure Chromatography. Selectivity Accelerated

SRT -10/10C (10 µm ) Fast Protein Purification For FPLC, HPLC and Prep LC. Sepax Technologies, Inc. Preparative Size Exclusion Chromatography

Kromasil Eternity Designed for long life

Analysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography

Transferring Yesterdays Methods to Tomorrows Technology: The Evolution from HPLC to UPLC TM

A Quality by Design (QbD) Based Method Development for the Determination of Impurities in a Peroxide Degraded Sample of Ziprasidone

Your Reversed Phase Method

FluoroPhenyl. Stationary Phase: Get the Power of HILIC and RP Modes in One LC Column. Pure Chromatography. Selectivity Accelerated

Reversed Phase Chromatography: Mobile phase Considerations

Fluophase and Fluofix Columns

for Acclaim Mixed-Mode WCX-1

Prep 150 LC System: Considerations for Analytical to Preparative Scaling

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SeQuant ZIC-HILIC. Catalogue 9. Hichrom Limited

Phenyl-Hexyl. UHPLC Columns. Alternate, complementary selectivity to C18 and C8 bonded phases

Isomer Separation on ZirChrom -CARB

Analysis of Positional Isomers of Lapatinib with Agilent Poroshell 120 PFP Columns

High Performance Liquid Chromatography. Table 1: Allowed HPLC Adjustment of USP <621> and EP <2.2.46>

Rapid, Reliable Metabolite Ratio Evaluation for MIST Assessments in Drug Discovery and Preclinical Studies

A Look at Agilent HPLC Columns Choices

Part 2. Overview of HPLC Media

Efficiently analyze your most challenging compounds. Deliver high-quality results faster. Agilent ZORBAX Column Selection Guide for HPLC

Uptisphere CS Evolution Core Shell columns for fast & highly efficient identification & quantification of small molecules

HPLC method development using alternative selectivities

P R O D U C T B U L L E T I N. Fused-Core particle technology for hyper-fast and super-rugged HPLC columns

Packings for HPLC. Packings for HPLC

Thermo Scientific Syncronis HPLC Columns. Remarkable separations guaranteed time after time

Automated Switching Between 1D-LC and Comprehensive 2D-LC Analysis

Exceptional Selectivity of Agilent ZORBAX Eclipse Plus Phenyl-Hexyl Columns to Separate Estrogens

surpass all possibilities [ Cortecs 2.7 µm columns ]

mau 200 ph min

( )( ) Selectivity Choices in Reversed-Phase Fast LC. Introduction. R s = 1 a 1 k 4 a 1 + k

Technical Guide Thermo Scientific Syncronis HPLC Columns

GUIDELINES FOR THE DESIGN OF CHROMATOGRAPHIC ANALYTICAL METHODS INTENDED FOR CIPAC COLLABORATIVE STUDY

Separation of Explosives in EPA 8330: Column Choices Optimize Speed, Resolution, and Solvent Use. Application. Authors. Abstract.

The Low-Temperature Evaporative Light-Scattering Detector (LT-ELSD)

HPLC & LC-MS. Techniques to Improve Speed, Resolution and Sensitivity without Investing in Capital Equipment

Looking into the HPLC Column while Running CIP

BÜCHI Labortechnik AG. Loadability _Company_Presentation BUCHI. For internal use only

Application Note Pharmaceutical QA/QC. Agilent Application Solution. Authors. Abstract. Syed Salman Lateef Agilent Technologies, Inc.

Pure Chromatography Consumables Pure flexibility. Pure specialization. Pure convenience.

TCI Chiral HPLC Column

Chemistry Instrumental Analysis Lecture 28. Chem 4631

HPLC Column Material - Bulk Ware

Analysis of Beer by Comprehensive 2D-LC with the Agilent 1290 Infinity 2D-LC system

Eliminating Unwanted Variability in LC Methods: More Uptime, More Sample Throughput

Uptisphere CS Evolution Core Shell columns for fast & highly efficient identification & quantification of small molecules

ProPac WCX-10 Columns

Too Polar for Reversed Phase What Do You Do?

Transcription:

Fortis 2.1µm 2.1µm Fortis C18 (2) High Efficiency Robust Particles Operate to 15,000psi Fully Scalable to analytical and prep size Fortis 2.1µm particles are designed to provide characteristics, which will aid in increased productivity within ultra high pressure chromatography (UHPLC). Designed to be robust, reproducible and fully scalable. Fortis 2.1µm particles will operate both on traditional LC systems, providing increased efficiency, and also on the latest UHPLC systems. Increased Efficiency 2.1µm Fortis C18 provides increased efficiency over 3µm and 5µm particles. This gives the opportunity to increase resolution or speed of analysis. 110 100 4 A wider linear flow range means that more resolution and peak capacity can be achieved for a given separation. By staying above 2µm particle size, Fortis 2.1µm C18 ensures pressure is reduced whilst no loss in efficiency is seen. 0.865 1.09 60717 N = 180,564 N = 130,191 2.1µm Fortis C18 3µm Fortis C18 90 3 2 Lower back pressure Higher Efficiency Greater Resolution Increased Sensitivity 0.325 1.39 13584 0.585 1.20 44615 1.520 0.94 85516 N = 88,708 2.243 0.93 88708 5µm Fortis C18 1 0 0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 - All columns 50x2.1mm Scalability and Sensitivity Critically important to the analyst is the ability to have a fully scalable separation. Fortis C18 can be scaled from 2.1µm all the way through analytical 3 and 5µm particles to prep size without any change in retention profile. 3µm Fortis C18 Diode Array Range: 3.628e+1 By moving from a 3µm particle size to 2.1µm Fortis C18 sensitivity can be increased. In this example peak height goes up by over 27% 4.0 6.0 8.0 10.0 12.0 14.0 16.0 18.0 20.0 22.0 2.1µm Fortis C18 Diode Array Range: 4.631e+1 4.0 6.0 8.0 10.0 12.0 14.0 16.0 18.0 20.0 22.0 3

Method Development Increase Speed Greater speed can be achieved by moving to smaller particles, whilst still obtaining full baseline resolution. 2.1µm Fortis C18 will operate at higher linear flow rates whilst providing lower backpressure than sub 2µm particles. 3.0x2.1mm 2.1µm 0.9ml/min 3.0x2.1mm 2.1µm 0.3ml/min 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 To move to smaller particles and smaller columns, without affecting selectivity, use the scaling equations to optimise your UHPLC parameters: e-mail us for the spreadsheet, technicalsupport@fortis-technologies.com 1.23 44383 1.45 2.64 91361 1.15 4.03 87565 1.09 7.26 92250 1.03 150x4.6mm 5µm 1.0ml/min 10.99 87249 1.00 Fortis 2.1µm 0 0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 11.0 12.0 Increase Resolution Greater resolution can be achieved by maintaining the column length and diameter but moving to a smaller particle size. 2.1µm Fortis C18 will provide very high efficiency and therefore peak capacity and resolution if used with longer column lengths. Columns can be coupled in series to provide extreme resolution capability 100x4.6mm 5µm Rs - 2.14 1.2ml/min 0.0 0 1.0 1 2.0 2 3.0 3 4.0 4 5.0 5 6.0 6 7.0 7 8.0 8 9.0 9 10.0 1. Cefadroxil 2. Cefachlor 3. Cefalexin 4. Cefradine Rs - 2.58 100x2.1mm 2.1µm 0.2ml/min 0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 2.1µm Fortis C18 (2) 2.1 F28-020202 F28-020302 F28-020502 F28-020702 Column Diameter 3.0 F28-030202 F28-030302 F28-030502 - 4.6 F28-050202 F28-050302 - - 4

0.685 2.07 0 0.843 5.19 144759 0.382 1.44 2162 1.675 1.49 60730 Fortis 2.1µm 2.1µm Fortis Phenyl High Efficiency and Alternative Selectivity Unique Robust di-phenyl Particles Chemistry Operate to 15,000psi Fully Scalable to analytical and and prep prep size size Providing Fortis 2.1µm an alternate particles selectivity are designed to traditional to provide C18 characteristics and C8 chemistries, which will Fortis aid Phenyl s in increased unique productivity di-phenyl structure allows ease within of separation. ultra high pressure Now the high chromatography efficiency of small (UHPLC). particles Designed can be to combined be robust, with reproducible selectivity to and ensure fully that resolution is optimised scalable. in ultra high pressure chromatography (UHPLC). Fortis 2.1µm particles will will operate both on on traditional LC LC systems, providing increased efficiency, and also on the latest UHPLC also on systems. the latest UHPLC systems. Alternative Selectivity - High Efficiency Particularly adept at separating closely related species Fortis Phenyl is also able to provide retention and separation of many species type whether polar or non-polar. Where alternate selectivity is required from C18 and C8 then Fortis Phenyl is the key choice. Column: Fortis Phenyl 50x2.1mm 2.1μ p/n: F2PH-020302 Mobile Phase: 80:20 H 2 O : ACN + 0.1% Formic acid 0.8ml/min Temp: 25 C Wavelength: 254nm Anti-Diabetic Resolution enhanced 1. Gliclazide 0 1 2 3 4 5 6 To learn more about the unique structure and separating power of Fortis Phenyl turn to page 15. 2.1µm Fortis Phenyl(2) 2.1 F2PH-020202 F2PH-020302 F2PH-020502 F2PH-020702 Column Diameter 3.0 F2PH-030202 F2PH-030302 F2PH-030502-4.6 F2PH-050202 F2PH-050302 - - Fortis Phenyl page 15 5

Fortis 2.1µm 2.547 0.56 121104 2.710 1.15 244355 1.717 1.58 39577 4.303 1.59 1311710 2.1µm Fortis C8 High Efficiency Robust Particles Operate to to 15,000psi Fully Scalable to to analytical and and prep prep size size Fortis C8 2.1µm 2.1µm particles particles are will designed provide to an provide advantage characteristics where the hydrophobicity which will aid in of increased a C18 is not productivity required. within C8 is also ultra often high used pressure as the chromatography first choice in method (UHPLC). development. Designed to be robust, reproducible and fully scalable. Fortis C8 2.1µm particles are designed to provide characteristics which will aid in increased productivity Fortis within 2.1µm ultra high particles pressure will operate chromatography both on traditional (UHPLC). LC Designed systems, to providing be robust, increased reproducible efficiency, and fully and also scalable. on the latest UHPLC systems. Hydrophobicity - High Efficiency Whatever the compound functionality Fortis C8 provides excellent performance. The high bonding density of C8 ligands can also provide resolving power different to that of C18 ligands. Hydrophobicity is reduced from that of a C18 ligand, allowing steroids and other lipophilic species to be analysed more quickly. Column: Fortis C8 50x2.1mm 2.1μ p/n: F208-020302 Mobile Phase: A - H 2 O + 0.1% Formic acid B - ACN + 0.1% Formic acid Gradient: Temp: 20 C Wavelength: 10-90% in 15min 0.4ml/min 254nm Hypertension Reduced hydrophobicity over C18 1. Telmisartan 0 2 4 6 8 10 12 14 2.1µm Fortis C8(2) 2.1 F208-020202 F208-020302 F208-020502 F208-020702 Column Diameter 3.0 F208-030202 F208-030302 F208-030502 - 4.6 F208-050202 F208-050302 - - 6

Fortis 2.1µm 2.1µm Fortis Cyano High Efficiency Robust Particles Operate to 15,000psi Fully Scalable to analytical and prep size Fortis Cyano 2.1µm particles are designed to provide alternative selectivity. Along with the other functionalities available on the Fortis 2.1µm particles this provides selectivity as well as increased efficiency for UHPLC analysis. Designed to be robust, reproducible and fully scalable, Fortis Cyano can be operated in normal phase as well reverse phase conditions. Alternative Selectivity - High Efficiency Fortis Cyano works for all types of compounds either in normal phase or reversed phase solvents. Peak shapes and efficiency will be of the highest order. Normal phase conditions will allow the retention of very polar analytes. Resolution enhanced Column: Fortis Cyano 50x2.1mm 2.1μ p/n: F2CN-020302 Mobile Phase: Heptane : THF : MeOH 90:5:5 1ml/min Temp: 25 C Wavelength: 254nm 1. Progesterone 2. 17αHydroxyprogesterone 3. 11αHydroxyprogesterone 4. Hydroxy-21-acetate 5. Cortisone 6. Prednisone 7. Prednisolone Steroids 0 1 2 3 4 5 6 To learn more about the separating power of Fortis Cyano turn to page 19. 2.1µm Fortis Cyano(2) 2.1 F2CN-020202 F2CN-020302 F2CN-020502 F2CN-020702 Column Diameter 3.0 F2CN-030202 F2CN-030302 F2CN-030502-4.6 F2CN-050202 F2CN-050302 - - Fortis Cyano page 19 7

Fortis 2.5µm 2.5µm Fortis C18 Over 20% more efficiency than 3µm Lower backpressure than UHPLC columns Operate in 400bar or 1000bar systems Fully Scalable to analytical and prep size Fortis 2.5µm particles are designed to be the next step in improving both resolution and speed. Allowing the analyst to move towards ultra high pressure chromatography (UHPLC) whilst still operating on traditional 400bar LC systems. Combined with the companies innovative PACE column design, 2.5µm particles offer speed and efficiency without compromising loadability and scalability. The optimised C18 bonding maintains the phases ability to be stable from ph 1-12. Optimised Resolution Resolution of closely related species can be achieved by the use of 2.5µm particles and the optimised peak shapes afforded by Fortis C18 stationary phase. Basic, Acidic and Neutral analyte performance is first class across the ph spectrum. Column: Fortis C18 100x4.6mm 2.5μ p/n: F18-050502 Mobile Phase: A - H 2 O + 0.1% Formic acid B - ACN + 0.1% Formic acid Gradient: 25-40% in 10min 1ml/min 5.5e6 5.0e6 4.5e6 4.0e6 Tricyclic antidepressants Resolution enhanced Temp: 20 C Wavelength: 1. Protriptyline 2. Nortriptyline 254nm 3.5e6 3.0e6 2.5e6 3. Amitriptyline 2.0e6 4. Trimipramine 1.5e6 1.0e6 0.0 0 1 2 3 4 5 6 7 8 9 10 To learn more about the stability and peak shapes of Fortis C18 turn to page 11. 2.5µm Fortis C18 2.1 F18-020202 F18-020302 F18-020502 F18-020702 Column Diameter 3.0 F18-030202 F18-030302 F18-030502 F18-030702 4.6 F18-050202 F18-050302 F18-050502 F18-050702 Fortis C18 page 11 8