A NEW DIGITAL ILLUMINANCE-METER WITH A SPECIAL LUMINANCE TUBEADAPTER FOR UNIVERSAL APPLICATIONS IN LIGHTING ENGINEERING

Similar documents
White Paper Luminance & Illuminance. Brief explanation of photometry for the application of tunnel lighting control

Key objectives in Lighting design

Measurement method for the proficiency testing program

Fundamentals of light

Fundamentals of light

Lighting fundamentals

Mesopic Photometry for SSL. Teresa Goodman Metrology for SSL Meeting 24 th April 2013

IES LM MEASUREMENT AND TEST REPORT. For

IES LM MEASUREMENT AND TEST REPORT. For

IES LM MEASUREMENT AND TEST REPORT. For

IES LM MEASUREMENT AND TEST REPORT. For

LUMINOUS MEASUREMENTS

CIE The Measurement of Luminous Flux. XIN Hongzheng

Photometric Laboratory Measurement report G001

Burning position correction for measurements with the turning luminaire LGS 1000

Spectral and photopic studies for high intensity discharge (HID) lamps

Improvement Uncertainty of Total luminous Flux Measurements by Determining Some Correction Factors

IES LM MEASUREMENT AND TEST REPORT For. IGT LIGHTING INC Lincoln St. Suite B, Riverside, CA Test Model: IGTFL

Radiometry and Photometry

Radiometry and Photometry

DIALux simulation for indoor tennis court 300lux

NIST Role in Supporting Solid State Lighting Initiative

A*STAR Seminar on LED and Solid State Lighting. Standards and Technologies. Measurements. 05 August LIU Yuanjie National Metrology Centre

Islamic University of Gaza - Palestine. Department of Industrial Engineering

OLLA White Paper on the Necessity of Luminous Efficacy Measurement Standardisation of OLED Light Sources

IES LM MEASUREMENT AND TEST REPORT. For. EiKO Global, LLC W 84th St Shawnee, KS Jeanne Han/Safety Manager

IES LM MEASUREMENT AND TEST REPORT. For. EiKO Global, LLC W. 84th St., Shawnee, KS Jeanne Han/Safety Manager

Application Note 1031

Aurora Ltd 6 Apex Park Welwyn Garden City AL7 4SW T: +44 (0)

2007 Technical University of Cluj Napoca, Lighting Engineering Center

LightLab I N T E R N A T I O N A L

TECHNICAL NOTE. Specifying Product Performance for Mesopic Applications

Test Report. Report No.: EED35I R1. Address : 701 Millennium Boulevard Greenville, SC : P , P , P , P

Test Report. Report No.: EED35I Address : 701 Millennium Boulevard Greenville, SC : P , P , P , P

Photometric Report. 42 Partners Limited 21 Woden Road Wolverhampton WV10 0AU UK

IALA Recommendation E On Marine Signal Lights Part 2 - Calculation, Definition and Notation of Luminous Range. Edition 1 December 2008

IES LM MEASUREMENT AND TEST REPORT For

Impact of New SSL Standards on Goniospectroradiometric Measurements

IES LM MEASUREMENT AND TEST REPORT For. Eiko Limited W. 84th Street,Shawnee, KS, USA. Test Model: LEDP-13WPAR30/NFL/830-DIM

CERTIFIED TEST REPORT No

IES LM TEST REPORT For Shenzhen sunper opto co., ltd

IST OLLA White Paper on the Necessity of Luminous Efficacy Measurement Standardisation of OLED Light Sources

Index. Symbols , 143

Photometric Analysis for Triple Tennis Court

AN AUTOMATED GONIOPHOTOMETER FOR LUMINAIRE CHARACTERIZATION

REPORT issued by an Accredited Testing Laboratory

1 General 1.1 Product Information Manufacturer Maxlite.Inc Page 2 of 17 Manufacturer Address 12 York Ave West Caldwell, NJ Brand Name Luminaire

LUXEON Flash. power light source. Introduction

LM Test Report. for. Forest Lighting Corporate. LED Tube. Model: FL-T8U BN

LightLab I N T E R N A T I O N A L

LightLab I N T E R N A T I O N A L

LightLab I N T E R N A T I O N A L

Introduction to Colorimetry

TEST REPORT For Company:

REPORT NO. Projection Lighting Date of Issue: 12/10/11 (Life) Issue G. Description: LED Luminaire Status at: 11/10/11

LM-79 Report TEST REPORT NO.M037D

LEDs in ERCO luminaires

Report No.: HZ p. (Lumens) Stabilization Time CRI (K)

Test report of IES LM Approved Method: Electrical and Photometric

General Information. Vishay Semiconductors. Explanation of Technical Data. Type Designation Code for LEDs

IES LM MEASUREMENT AND TEST REPORT. For

Del 1: Mätning och filformat

ALS - PD70-01C/TR7. Surface - Mount Ambient Light Sensor. Features. Description. Applications

SPEC NO: DSAJ6327 REV NO: V.1 DATE: JUL/31/2009 PAGE: 1 OF 8 APPROVED: WYNEC CHECKED:

DAYLIGHT FACTOR DISTRIBUTION IN INTERIOR BASED UPON THE MEAN SKY

Section 22. Radiative Transfer

SPEC NO: DSAJ6328 REV NO: V.1 DATE: JUL/31/2009 PAGE: 1 OF 9 APPROVED: WYNEC CHECKED:

PERFORMANCE EVALUATION OF DIMMABLE LIGHTING SOURCES WITH FLUORESCENT TUBES FOR INDOOR APPLICATIONS

LM-79 Report TEST REPORT NO. L523A

IES LM MEASUREMENT AND TEST REPORT For

Chartered Institute of Building Service Engineers (CIBSE) code for interior lighting design

Fundamentals of Rendering - Radiometry / Photometry

Fundamentals of Rendering - Radiometry / Photometry

Section 10. Radiative Transfer

VI. Terminology for Display

Using a Quantitative Measure to Achieve a Qualitative Lighting Design Effect! Introduction What is Luminance?

FluxGage - A Photometric Test System for LED Luminaires Based on Solar Panels

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Through Hole Lamp Product Data Sheet LTL-403G Spec No.: DS Effective Date: 01/13/2004 LITE-ON DCC RELEASE

NVLAP LAB CODE LM Test Report. For AOK LED LIGHT COMPANY LIMITED. (Brand Name: AOK)

Methods of total spectral radiant flux realization at VNIIOFI

LEDs in ERCO luminaires

LM Test Report. for MLS CO., LTD. Linear Ambient Luminaires Model: MT8N20-A

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Photometric Test Report

IES LM TEST REPORT For EIKO GLOBAL, LLC

Determination of Photometric Properties of Materials for Energy Purposes Through the Experimental Study of a Two-Axis Goniophotometer

1 Client The request to draft this report was made by DELTA Light & Optics, Venlighedsvej 4, DK-2970 Hørsholm, Denmark.

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

DESIGN CRITERIA FOR TUNNEL LIGHTING

Lighting Sciences

LightLab I N T E R N A T I O N A L

New Method for Realizing a Luminous Flux Scale using an Integrating Sphere with an External Source

TEST REPORT IES LM For Signlite Opto-electronics Co.,Ltd.

Page 2 of 14 Report No.: Test sample... : Type of test object... : LED Downlight LED Downlight

8165 E Kaiser Blvd. Anaheim, CA p f NVLAP LAB CODE

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

LM Test Report. for MLS CO., LTD. Linear Ambient Luminaires Model: MT5Z02-6

LM Test Report. for MLS CO., LTD. Linear Ambient Luminaires Model: MT5Z02-9

Standard-Tech Co. Ltd Testing Center

Transcription:

1 A NEW DIGITAL ILLUMINANCE-METER WITH A SPECIAL LUMINANCE TUBEADAPTER FOR UNIVERSAL APPLICATIONS IN LIGHTING ENGINEERING Peter Marx University of Applied Sciences Berlin, Germany Distributed by OPTE-E-MA Engineering GmbH Ehrenbergstr. 11 - D-98693 Ilmenau - Tel. +49 3677 668 260 - www.opteema.com SUMMARY A new digital illuminance-meter MINILUX with a special luminance-tubeadapter is developed by the University of Applied Sciences Berlin in cooperation with the Technical University of Zhejiang China for universal applications in lighting engineering. ZUSAMMENFASSUNG Ein neues Digital-Luxmeter MINILUX mit einem speziellen Leuchtdichte- Vorsatztubus wurde von der University of Applied Sciences Berlin in Kooperation mit der Technical University of Zhejiang China für universelle Anwendungen in der Lichttechnik entwickelt. SOMMAIRE Un nouveau luxmètre digital MINILUX avec un tube pour mesure de luminance pour les applications universelles de l éclairage a été evolué par la University of Applied Sciences Berlin en coopération avec la Technical University of Zhejiang China pour les applications universelles à la technique de l éclairage.

2 1. Introduction Compared with the total turnover of electrical engineering, the extent of lighting technics is constantly rising. Therefore, the exact measurement of light technical quantities such as illuminance, luminance, luminous intensity and luminous flux gains more and more importance. The following article presents a new, reasonable, universally usable and portable digital illuminance-meter for accurate illuminance and luminance measurements. The measuring of luminous flux, luminous intensity and luminance is based on the measuring of illuminance by means of the photometric fundamental law. That is, why this quantity has got a special significance. A state-of-the-art illuminance-meter should have the following conditions. 2. Technical requirements on a state-of-the-art illuminance-meter Fine approximation to the spectral luminous efficiency curve V(λ) of the human eye Photometer-head with cosine-correction Linear relation between illuminance and photocurrent Low temperature influence, ageing and fatigue of the lightsensor Correct light- measurement of AC-powered discharged lamps (linear mean of wavy light in accordance with the Talbot-Plateau law ) Wide measure range, so that the following measurements are possible with just one instrument: - measuring of daylight up to 200000 lx - measuring of indoor lighting up to 2000 lx - measuring of low illuminances, e.g. street lighting up to 20 lx - Emergency-lighting up to 2 lx Simple operation, that means no application of weakening filters and correctionfactors Correct reading of the measuring results by a digital display 3. Functions of the digital luxmeter Based on the mentioned conditions, the digital illuminance-meter Minilux was developed at the University of Applied Sciences, Berlin in cooperation with the Technical University of Zhejiang, China. Concrete, it is a newly developed, portable illuminance-meter for universal applications concerning the whole lighting technic (Fig. 1).

3 Fig. 1. The MINILUX- device with photosensor (silicon-cell with V(λ)- and cosinecorrection in accordance to DIN 5032, class B) Fig. 2 shows the block diagram of Minilux. Two amplifiers with an extremely low bias-current are used for protection against overload, when for example high pressure sodium-xenon lamps with pulsed current supply and a high luminous flux crest-factor are measured (Fig. 3). The first amplifier OPA 1 serves the range, the second OPA 2 works as a mean-forming active low-pass-filter. Fig. 2. Block circuit of the Minilux illuminance-photometer. Measurement capacity: 0.001 lx..199.9 klx (6 ranges), luminance capacity: 0.1 cd/m2..19.99 Mcd/m2 (6 ranges)

4 Fig. 3. Time dependence of the luminous flux of a sodium-xenon HID-lamp supplied by pulsed high-frequency current Accurate photometry of high-pressure discharge lamps with pulsed current supply calls for a special photocurrent amplifier, which, in accordance with the Talbot-Plateaulaw, reliably estimate the linear mean value of luminous flux. Ordinary luxmeters are generally not designed to measure high pulsating light sources. Therefore, to avoid errors, the staff of photometric laboratories should heed this recommendation before measuring such light sources. Critical evaluation and investigation of the suitability of the photometer for measurements of pulsating light is required. The new measuring instrument avoids these disadvantages and thereby closes a gap in the market. 4. Important technical data Silicon photosensor with V(λ)- and cos-correction (Fig. 4, Fig.5) Diameter of the sensitive light area D = 11mm 6 lux-ranges Total measure range: 1 mlx to 199900 lx Resolution: 1 mlx Class B in accordance with DIN 5032, section 6 Crestfactor: about 15 dual-slope-digitalvoltmeter with auto-zero 7-segment LC-display Automatic low-battery-indicator, if U bat < 7V Supply-current : only about 2 ma 9-V-lithium-blockbattery with 1,2 Ah (working time of the Minilux with this highperformance battery approximately 600 hours!) Analog output 1: to measure the waveform of illuminance E(t) with an oscilloscope Analog output 2: 0... 199.9 mv DC for recorder, plotter, PC etc 4-seconds-delay timer with indication-hold-function inclusive of

5 display- light and display-functioning test measurings ) Dimensions: 157 mm x 84 mm x 30 mm Weight: 300g Price: 400 USD (e.g. suitable for shadingfree Fig. 4. V(λ)- approximation of the silicon-photosensor in accordance to DIN 5032, class B

6 Fig. 5. Cosine-correction of the silicon-photosensor The instrument measures lux-values from: 1 mlx (resolution) to 199900 lx. (Note: 1 fc = 10.764 lx // 1 lx = 0.0929 fc) Range Typical application 0.000...1.999 lx Emergency measurements 00.00...... 19.99 lx Street lighting measurements 000.0......199.9 lx Interior lighting measurements 0.000...1.999 klx Interior lighting measurements 00.00......19.99 klx Daylight measurements 000.0......199.9 klx Daylight measurements Fig. 6. Luminance-tubeadapter for the Minilux-photometer The special luminance-tubeadapter (Fig. 6) has a measuring angle of α = 13º. The tube-geometry is so calculated, that the relation between luminance and illuminance is very simple: L = 100 E E in lx, L in cd/ m² The procedure of luminance-measurement is as follows: Put the luminance-tubeadapter on the photocell and hold the tube in the direction, in which you want to measure the luminance of a surface. Read the lux-value from the

7 minilux-display and multiply this lux-value with the constant factor 100. The result is the actual average luminance. Luminance-capability: 0.1 cd/m²...19.99 cd/m² (6 ranges) Procedure for reflection-measurements of a diffuse surface: First measure the illuminance on the surface. Then measure the luminance of the surface at the same area. Calculate the reflection-value with the following formula: ρ = (π L) / E E in lx, L in cd/ m² 5. Fields of applications The instrument is suitable for the measuring of illuminance, luminance and reflection the measuring of luminous intensity by means of the photometrical law: I [cd] = E [lx] (R [m])² luminous flux measurements in accordance with Φ [lm] = E [lx] A [m²] Further applications are possible, e.g. for: luminous flux measurements in conjunction with the Ulbricht sphere control of the turning on and off of street luminaires brightness control for roadway tunnels Measurements of building materials used in lighting technology (e.g. for measurement of reflection, transmission, absorption, extinction etc.) Measurements for solar facilities Light measurements for applications in physics, optoelectronics, meteorology, botany, biology and medicine 6. Result The new lux-meter provides a metrological basis for innovative, energy-efficient and consequently environmentally benign lighting systems. It supports systems based on the use of natural daylight in conjunction with supplementary artificial illuminance which is controlled in accordance with user demand, and which is equipped with dimmable high-frequency electronic ballast devices, which enables power savings of up to 70 %. The presented digital luxmeter contributes to the achievement of this aim.

8 References DIN 5032 Lichtmessung, sections 1...7 P. Marx, New Goniophotometers for Lighting-engineering Laboratories. CIE 24 TH Session, Warsaw 1995, Proceedings Vol. 1, Part 1, page 189 192 Ye Guanrong, Light-sensor for photometry. Zhejiang University, Hangzhou, China OPTE-E-MA Engineering GmbH Tel. +49(3677)668 260 Ehrenbergstr. 11 Fax. +49(3677)668 261 D-98693 Ilmenau - Germany e-mail: info@opteema.com Internet: www.opteema.com