Evaluation of standards for transmission loss tests

Similar documents
inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

LABORATORY MEASUREMENTS OF THE SOUND ABSORPTION OF CLASSICTONE 700 ASTM C Type E Mounting. Test Number 2

MEASUREMENTS OF SOUND ABSORPTION TIMBERCRETE

THE ACOUSTIC IMPEDANCE MEASUREMNET SYSTEM USING TWO MICROPHONES

REPORT ON THE DETERMINATION OF SOUND ABSORPTION COEFFICIENTS OF WOVEN IMAGE ECHO PANEL 7MM TESTED WITH A 20MM AIR GAP IN A REVERBERATION ROOM.

MAC Aura XB Acoustic Test Report

Development of a small-scale reverberation room

REPORT ON THE DETERMINATION OF SOUND ABSORPTION COEFFICIENTS OF WOVEN IMAGE ECHO PANEL 24MM TESTED WITH NO AIR GAP MEASURED IN A REVERBERATION ROOM.

Test Report. RI Acoustic Lab. Measurement of Sound Absorption Coefficient for RockDelta NoiStop Noise Barrier. 20 Feb. 07

Measurement of Acoustic Properties of light weight concrete SL-Deck

Sound radiation and transmission. Professor Phil Joseph. Departamento de Engenharia Mecânica

Acoustic design of lightweight cabin walls for cruise ships

Testing Procedure: AS ISO

ISO INTERNATIONAL STANDARD

Measurement of sound absorption coefficient for Fraster felt SpaceCover

The diagram below. to the by the. outlet into. calculation. Since TRANSMISSION VIA STRUCTURE. Vibration Via Supports Duct Breakout

QUANTIFYING ACOUSTIC SOURCES THROUGH SOUND POWER MEASUREMENTS

ETS-LINDGREN ACOUSTIC RESEARCH LABORATORY OFFICIAL LABORATORY REPORT ARL-SA6712/ARL-SA6713 Revision 0 ARL

DELTA Test Report. DANAK TEST Reg. no Measurement of Sound Absorption Coefficient for Kvadrat Soft Cells Wall Panel Type Time

COMPARISON OF THE METHODS TO CALIBRATE THE DIFFUSE FIELD SENSITIVITY OF LABORATORY STAND- ARD MICROPHONE

ETS-LINDGREN ACOUSTIC RESEARCH LABORATORY OFFICIAL LABORATORY REPORT ARL-SA6956 Revision 1 ARL

Consultancy Report Ref: 9383-R01

ETS-LINDGREN ACOUSTIC RESEARCH LABORATORY OFFICIAL LABORATORY REPORT ARL-SA6266/ARL-SA6274 Revision 0 ARL

Acoustical Design of Vehicle Dash Insulator

DELTA Test Report. Measurement of Sound Absorption for AqFlex ON, one Sample as a discrete Object. Performed for Flex Acoustics

ODEON APPLICATION NOTE Calibration of Impulse Response Measurements

ETS-LINDGREN ACOUSTIC RESEARCH LABORATORY OFFICIAL LABORATORY REPORT ARL-SA6986/ARL-SA6987 Revision 0 ARL

Laser scanning vibrometry measurements on a light weight building element

ACOUSTIC INTRINSIC PERFORMANCES OF NOISE BARRIERS: ACCURACY OF IN SITU MEASUREMENT TECHNIQUES

TFI Report Sound Absorption Impact Sound Insulation

DELTA Test Report. Measurement of sound absorption coefficient for 15 mm Fraster felt Plus acoustic panels with mounting depth 45 mm

ECMA Measurement of airborne noise emitted and structure-borne vibration induced by small air-moving devices Part 1: Airborne noise measurement

Some issues in measurement of the random-incidence scattering coefficients in a reverberation room

Design of Partial Enclosures. D. W. Herrin, Ph.D., P.E. University of Kentucky Department of Mechanical Engineering

SOUND TRANSMISSION LOSS MEASUREMENTS - AN AUTOMOTIVE OVERVIEW

Engineering Noise Control

Sound power level determinations at laboratory and field environments: An experimental comparison

FDTD analysis on the sound insulation performance of wall system with narrow gaps

9. TRANSMISSION OF SOUND THROUGH STRUCTURES

TFI Report Sound Absorption Impact Sound Insulation

Numerical Model of the Insertion Loss Promoted by the Enclosure of a Sound Source

Available online at ScienceDirect. Energy Procedia 78 (2015 ) th International Building Physics Conference, IBPC 2015

Available online at ScienceDirect. Energy Procedia 78 (2015 ) th International Building Physics Conference, IBPC 2015

ACOUSTIC TESTS ON ORIGINAL CONCRETE AND INERT MIXTURE MATERIALS

Modeling and simulation of windows with noise mitigation and natural ventilation

Sound radiation and sound insulation

A L I O N Technical Center. Test Report

Laboratory for Acoustics. Determination of the sound insulation of sliding door constructions, manufactured by Metaflex

TFI Report Sound Absorption Impact Sound Insulation

Production Testing of Noise from Business Machines

Acoustic response in non-diffuse rooms

Comparison of Path Rank Ordering Schemes for Structure-Borne Noise

Radiated sound power estimates of building elements by means of laser Doppler vibrometry

Drop towers and fitness flooring assemblies

SOUND ABSORPTION OF SLAT STRUCTURES FOR PRACTICAL APPLICATIONS

EUROVENT 8/12 SOUND TEST METHOD FOR DUCTED FAN COIL UNITS. FCP 2008 testing procedures FCP acoustical test method pag. 1

Random incidence transmission loss of a metamaterial barrier system

Gesellschaft für Akustikforschung Dresden mbh Acoustic Engineering Dresden AED Acoustic Measuring Instruments & Analysis Software

45º CONGRESO ESPAÑOL DE ACÚSTICA 8º CONGRESO IBÉRICO DE ACÚSTICA EUROPEAN SYMPOSIUM ON SMART CITIES AND ENVIRONMENTAL ACOUSTICS

Number Title Year Organization Page

1238. Relation between reduction of weighted impact sound pressure level and shape of small size specimen of floating floor construction

CONSOLIDATED GRANULAR MEDIA FOR SOUND INSULATION: PERFORMANCE EVALUATION THROUGH DIFFERENT METHODS

Part 2: Methods for special reverberation test rooms

Impedance of standard impact sources and their effect on impact sound pressure level of floors

EXPERIMENTAL VERIFICATION OF THE EUROPEAN METHODOLOGY FOR TESTING NOISE BARRIERS IN SITU: SOUND REFLECTION

Turbines and turbine sets Measurement of emitted airborne noise Engineering/survey method

Numerical modeling of the primary source in a hemi-anechoic room

R & D AKUSTIKA * SIA. Test Report of laboratory Sound Insulation measurements Nr. 569 / 2011 AL 8.4. CUSTOMER: AEROC AS (Estonia)

RIVERBANK ACOUSTICAL LABORATORIES

TFI Report Sound Absorption Impact Sound Insulation

Page 1 of 10 pages Appendix, 5 pages Report no.: P Glostrup, October 12th 2012 Project: Claimant:

Answer - SAQ 1. The intensity, I, is given by: Back

LABORATORY MEASUREMENTS OF THE REDUCTION OF TRANSMITTED IMPACT NOISE PANETTI OVERLAID BY CONCRETE FLOORING

Benefits of Reduced-size Reverberation Room Testing

Standard ECMA-108 3rd Edition - December Measurement of High-frequency Noise emitted by Information Technology and Telecommunications Equipment

Sound Engineering Test and Analysis

LABORATORY MEASUREMENTS OF THE SOUND ABSORPTION COEFFICIENTS OF OSCAR EVO-PANELS

1. Introduction. 2. ISO 3745 and ISO standard comparison

ROLLEASE ACMEDA ACOUSTICAL PERFORMANCE TEST REPORT

Notes on Absorption and Impedance Measurements

Roller blind fabric PRIMACOUSTIC R

The influence of Boundary Conditions on Sound Insulation

Porous Materials for Sound Absorption and Transmission Control

PART VIII: ABSORPTIVE SILENCER DESIGN

A suggested method to be used to measure scattering coefficients of full scale samples.

Fabric Dazzle 6086 Manufacturer Carnegie Fabrics

Yalıtım Kontrol Koruma. Insulation Control Protection

Uncertainties associated with the use of a sound level meter

Radiated Sound Power from a Curved Honeycomb Panel

An examination of some aspects of the use of ISO 140 Part 4 and 7 in field measurements.

Investigations on real-scale experiments for the measurement of the ISO scattering coefficient in the reverberation room

LABORATORY MEASUREMENT OF SOUND ABSORPTION OF SONOGLASS SPRAY-ON TREATMENT IN THREE CONFIGURATIONS

Analytical and experimental study of single frame double wall

REPORT N CR

ISO INTERNATIONAL STANDARD

TRANSMISSION LOSS OF EXTRUDED ALUMINIUM PANELS WITH ORTHOTROPIC CORES

INVESTIGATIONS INTO THE PERFORMANCE OF THE REVERBERATION CHAMBER OF THE INTEGRATED ACOUSTICS LABORATORY. A Thesis Presented to The Academic Faculty

A L I O N Technical Center. Test Report. Port Coquitlam, British Columbia, Canada

Fabric REFLECTACOUSTIC

Static pressure and temperature coefficients of working standard microphones

Transcription:

Evaluation of standards for transmission loss tests M. Cassidy, R. K Cooper, R. Gault and J. Wang Queen s University Belfast, School of Mechanical and Aerospace Engineering, Ashby Building, Stranmillis Road, BT9 5AH Belfast, UK mcassidy06@qub.ac.uk 1675

FG Wilson, a generator set manufacturer in Larne, UK, (part of the CAT Electric Power Division), has an acoustics facility for obtaining noise emission of current products, future developments and research. A wall between a hemi-anechoic chamber and a reverberation room contains an aperture which is used for testing canopy panels to determine their sound transmission loss. Two different standard procedures for transmission loss testing are compared; the J1400, and ISO 15186. Tests were carried out on both to determine which is most feasible for the company to use. The J1400 is a variation of the ASTM E90 which uses the same method but is specifically for a reverberation room to hemi-anechoic chamber. A known limp material, chosen to be lead, is used to obtain a transmission loss correction. ISO 15186 is based on a sound intensity method. A microphone on the source side recorded the sound pressure levels, and an intensity mapping was done on the receiving side, from which transmission loss was calculated. Two tests were completed; a lead sheet, and a steel plate. Both standards showed an acceptable accuracy in relation to the mass law. 1 Introduction Built in 2005, the Acoustic Centre of Excellence at FG Wilson in Larne, contains a hemi-anechoic chamber for testing the noise emission of their generator sets, and a reverberation room for measuring the absorption of lining material. There is also an opening between these two rooms which is used for transmission loss of canopy panels and future research. For anticipation of a large number of tests in order to build a database, there is the need for a standard method of transmission loss testing. Transmission loss is the property of a wall or barrier that defines its effectiveness as an isolator of sound [1]. It is also referred to as the sound reduction index, and is computed from the logarithmic ratio of sound power incident to sound power transmitted, eq (1). SoundP owerincident T L = 10 log (1) SoundP owert ransmitted From recommendations of similar test facilities, and a search through international standards, two of the most relevant methods were the American National Standard for laboratory measurement of the airborne sound barrier performance of automotive materials and assemblies, the SAE J1400, and the International standard for measurement of sound insulation in buildings and of building elements using sound intensity, the ISO 15186. The J1400 is associated with the ASTM E90 International Standard Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions and Elements, and is used instead because the ASTM E90 does not cater for a reverberation room to hemi-anechoic chamber. The first noticeable difference between the two standards is that the J1400 uses microphones to measure sound pressure levels in both rooms, whereas the ISO 15186 uses intensity measurements in the hemi-anechoic chamber to calculate the transmission loss. Another major difference is the use of a reference sample as calibration in the J1400, from which the unknown sample is calculated by inputting a correlation factor. 2 Method 2.1 Theory Sound transmission loss is the logarithmic ratio of sound power incident to sound power transmitted, eq (1). It can be evaluated from eq (1) that: W 1 incident sound power W 2 transmitted sound power T L = 10 log W 1 W 2 (2) For ISO 15186 the sound intensity is measured therefore using power is equal to intensity times area: W 1 = I 1 S (3) W 2 = I 2 S m (4) I 1 incident sound intensity I 2 transmitted sound intensity S area of the test specimen S m area of the measurement surface, Fig2 Since sound pressure levels are recorded in the reverberation room, the effective intensity in one direction of a diffuse field is [2]: I 1 = P 2 1 P 1 is the source sound pressure ρc is the acoustic impedance From eq (3) and eq (5) W 1 = P 2 1 S therefore from eq (2), eq (4), and eq (6) T L = 10 log P 2 1 S (5) (6) 1 I 2 S m (7) T L = 10 log P 2 1 10 log () 10 log I 2 +10 log S S m (8) To convert sound pressure into sound pressure level, and sound intensity to sound intensity level: T L = 10 log P 2 1 P 0 P 0 10 log () 10 log I 2 I 0 I 0 + 10 log S S m (9) P 0 is the reference sound pressure (2 10 5 P a) I 0 is the reference sound intensity (10 12 W/m 2 ) 1676

Acoustics 08 Paris source sound pressure level, i.e. the same for both, however eq (11) converts this to intensity with the 6dB difference and the inclusion of the test specimen area S. Because eq (11) calculates transmission loss as the difference between sound intensity levels it is recognised from eq (18) that LP 2 corresponds to the sound intensity level LIn and the measurement surface area Sm. Eq (9) becomes: TL = LP 1 + 10 log 10 log () S LIn 10 log I0 + 10 log Sm (10) LP 1 average source sound pressure level LIn average transmitted sound intensity level 2.2 Substituting the values for the constants eq (10) becomes: T L = LP 1 6 [LIn + 10 log S ] Sm Equipment required for both include the reverberation room setup containing two speakers and a diffuse field microphone on a rotating boom. Other items are coaxial cables, networks leads, microphone calibrator, data acquisition unit, and a computer with the relevant software. J1400 states the number and spacing of microphone positions required in each room depends on the statistical precision desired, but from prior work to determine the accuracy of measurements, the selected number of microphones was three, spaced at the positions stated in table 1. (11) Eq (11) is used to calculate the transmission loss for the international standard ISO 15186. In comparison the J1400 evaluates the TL from eq (12) T L = M N R(unknown) CF (12) Microphone M N R(unknown) measured noise reduction of the unknown sample CF correlation factor, eq (13) CF = M N R(ref erence) T L(ref erence) (14) 1 2.11 0.61 2 2.91 1.18 3 2.38 1.75 Fig1 shows the microphone positions in relation to the test piece. They are mounted on rods and fixed in tripods at a distance of 22inches from the sample. In comparison only one tripod is needed for the intensity probe, but this is not at a fixed position and moves over a box grid as shown in Fig2 and Fig3. The measured noise reduction is calculated from eq (1) where TL now becomes: Pi2 Pt2 Distance from LHS (m) Table 1: Microphone positions in hemianechoic chamber W surface density, kg/m2 f centre frequency of the third octave band T L = 10 log Height from floor (m) (13) M N R(ref erence) measured noise reduction of the limp material T L(ref erence) mass law of limp material, eq (14) T L(ref erence) = 20 log W + 20 log f 47.2 Setup (15) Pi incident sound pressure Pt transmitted sound pressure Eq (15) is converted to sound pressure levels as before P2 P2 T L = 10 log i2 10 log t2 (16) T L = 20 log Pt Pi 20 log T L = LP 1 LP 2 (17) Figure 1: Three microphone positions for the J1400 tests. (18) LP 1 average sound pressure level in source room LP 2 average sound pressure level in receiving room 2.3 Eq (18) is used to calculate the measured noise reduction (MNR) as stated in the standard J1400. It can be compared to eq (11) for ISO 15186 as there is similarity in transmission loss calculation since LP 1 is the Software Pulse LabShop, produced by Bru el and Kjær, is designed for the type of tests required, and provides ease of use through pre-programmed applications. 1677

Acoustics 08 Paris mass law, this difference is the correlation factor eq (13). Figure 2: Measurement grid for the ISO 15186 Figure 4: Calculated correlation factor from the reference sample. Repeating the test of the lead sheet with a steel plate, the transmission loss for this unknown sample is found, Fig5. This is done by subtracting the correlation factor from any measured transmission loss using the J1400 method to predict the actual transmission loss as stated in eq (12) Figure 3: Intensity probe used for the ISO 15186 tests The initial step is to detect all connections to the software, this includes the speakers as outputs, the diffuse microphone as an input and for the J1400 the three microphones as the other inputs, but for the ISO 15186 the intensity probe is the input. For both tests the signal generated for the reverberation room through the speakers is sourced from the software with white noise through one speaker and pink noise through the other. The diffuse field microphone in the reverberation room is set on a rotating boom with a 64 second cycle. After calibration of recording equipment the background sound levels are recorded in both rooms for a check to be carried out later. The next step is to use the graphics equaliser to adjust the source sound levels in the reverberation room. When this is complete the transmitted sound can be recorded. For the J1400 this is carried out with an average of three readings. Each reading consists of the average of the three microphones captured as 128s linear averages. The ISO 15186 test is setup differently with 18 second averages recorded for each grid point. There are 96 points to measure, and they are averaged according to the standard. Measurements are exported from the Pulse software to a spreadsheet where calculations are carried out. Also exported are the calibration data and background levels to complete the necessary checks. 3 Figure 5: Transmission loss of steel using the J1400. Fig6 shows the transmission loss of steel for ISO 15186, calculated using eq (11). From this graph it is observed that there is very good correlation for the frequency range 100Hz to 1250Hz. The large differences at the higher and lower frequencies can be accounted for by stiffness and damping. Figure 6: Transmission loss of steel using the ISO 15186. Another comparison is the lead sheet tested using the ISO 15186 to compare its accuracy with the mass law for lead. Fig7 shows great correlation for the 100Hz to 1250Hz, which was the same as the steel. The issues arising due to the stiffness and damping are observed again, but are not as large due to lead being a limp material. Results The correlation factor for the J1400 was calculated from the transmission loss measured from the average of the three recorded values over the frequency spectrum. Fig4 shows the difference between the recorded data and the 1678

Figure 7: Transmission loss of lead using ISO 15186. The overall comparison for both standards with the mass law for steel is observed in Fig8. It can be seen how accurate the standards are to the mass law, but also how well the two standards correlate with each other. Fig9 shows the difference between the ISO 15186 and the J1400. As can be seen the difference lies within 2dB with two outlying third octave bands at 160Hz and 1600Hz. The most important comparison is represented by Fig9 which compares the standards. From this graph it can be said that both the J1400 and the ISO 15186 predict the same sound transmission loss. This shows that both are suitable for testing noise reduction of a partition, but this study has been carried out to find the most appropriate method for FG Wilson to use. A method of recording sound using microphones is easier from the setup and testing technique. However there is one major disadvantage using the J1400, this is the need to have a reference material tested first before testing the unknown. As a result this is not the most suitable for FG Wilson due to the setup of replacing the test piece each time being very time consuming, therefore requiring a whole day for one test. The alternative is to use the intensity method, although the setup takes longer and the probe must be positioned manually, the test takes only two hours to complete. This favours the ISO 15186 as being the method to use since there is very little difference in actual results. 5 Conclusion For FG Wilson the test method to find transmission loss will be the international standard ISO 15186 which utilises the sound intensity method. It has been shown from this research that the measurements used to predict the sound transmission loss result in very close correlation, so it is the actual facilities setup and availability of equipment that determine which method to use. Figure 8: Comparison of the J1400 and ISO 15186 with the mass law for the steel. 6 Acknowledgments The authors thank FG Wilson, Larne for use of their facilities and personnel to carry out the tests. References [1] B. J. Smith, R. J. Peters, S. Owen, Acoustics and Noise Control, Second Edition Addison Wesley Longman Limited, 151 (1996) [2] David A. Bies, Colin H. Hansen, Engineering Noise Control, Third Edition Spon Press, 287 (2003) Figure 9: The difference between the transmission loss using the J1400 and ISO 15186 for steel. 4 Discussion As an accurate measure of sound transmission loss both the standards correspond well to the mass law as shown in Fig8, there are however inaccuracies at frequencies below 100Hz, and above 1250Hz. These can be accounted for due to resonances at low frequencies and coincidence effect at high frequencies causing a deviation from the mass law. 1679