Multipette / Repeater M4 allows for fast, precise and sterile liquid transfer in cell culture

Similar documents
Precise and Accurate whole Blood Dispensing with Multipette E3x and Combitips advanced

Superior well-to-well Consistency with Eppendorf Cell Culture Plates

Spa & Wellness for Pipettes

Larger Display Easier to Use. Generation E. Repeater E3 and E3x: Dispense without compromising accuracy or precision

Simply Better Pipetting

ept.i.p.s. pipette tips are available with various degrees of purity, with and without filters, and as special tips.

Eppendorf ept.i.p.s. LoRetention Comparison of low retention pipette tips via simple and fast absorbance measurements in the BioPhotometer plus

Technical Report Exact dispensing of whole blood using the Eppendorf positive displacement system Multipette Xstream /Repeater Xstream

NEW! ep Dualfilter T.I.P.S. Peak of perfection

96 Well? Done! Eppendorf epmotion 96 semi-automated electronic pipette for fast and precise 96 channel microplate processing

Eppendorf Xplorer Eppendorf Xplorer plus. Ordering information. Register your instrument!

N) justment. Register your instrument! Eppendorf Research plus. Factory Adjustment

The Pure Truth. Eppendorf Forensic DNA Grade according to ISO 18385

ept.i.p.s. Instructions for use Version B

The New Legend. Eppendorf Reference 2 Pipette

1 Product description. Material. 3 Warnings for intended use. Instructions for use ept.i.p.s. Version B. English (EN)

Well within Reach. The Eppendorf Pipette Holder System

PhysioCare Concept improved. The feeling of a new philosophy

N) manual. Biomaster Operating manual

PhysioCare Concept improved. The feeling of a new philosophy

The New Legend. Eppendorf Reference 2 Pipette

Spa & Wellness for Pipettes

Get the Eppendorf Advantage!

No 022 December Application-Specific Requirements for Consumables in the Laboratory

NEW: 5.0 ml screw cap tube. The Missing Link. Eppendorf Tubes 5.0 ml Discover a new sample handling system

PhysioCare Concept. Make your Lab a better place

Promotion period: September 15 - December 31, Super Sale. Quality at unbeatable prices

December 2010 No 036. The electronic Eppendorf Xplorer pipette Versatile adjustment

Now also in Eppendorf LoBind. Conical Competence. Eppendorf Conical Tubes 15 ml and 50 ml

Raise the limits. Eppendorf Research plus

Cell Biology (Eukaryotic Cells)

Automated purification of high quality genomic DNA

NGS Made Easy. Optimize your NGS library preparation with the epmotion Automated liquid handling system

The New Eppendorf X-Drive - Maximum Performance, Flexibility and Longevity for Demanding Shaker Tasks

Eppendorf Reference : The pipette.

ept.i.p.s. Version A

New Promotions July 1 December 31, Take Good Care of Your Cells. More great offers for your cell biology processes

Still Making History. Over 50 years of pipetting

Applications Note 215 September 2009

Simply better pipetting!

Automation of Routine Microplate Pipetting and Dispensing

ab83360 Ammonia Assay Kit

Natural Winners. Eppendorf Liquid Handling Instruments: Unrivaled in technology, efficiency and handling for over 50 years

ab83360 Ammonia Assay Kit

New Promotion January 1 June 30, Take Good Care of Your Cells. Smart solutions from Eppendorf for your cell biology processes

Natural Winners. Eppendorf Liquid Handling Instruments: Unrivaled in technology, efficiency and handling for over 50 years

New Eppendorf Advantage Promotion Sept. 1 Dec. 31, 2016 Your expertise + our equipment. Save up to 20 % with our new special offers!

Electrical safety testing Checklist

Automated pipetting made easy new ep Motion 5073 family members for perfect PCR set-up and nucleic acids purifi cation or general liquid handling

Eppendorf PCR Consumables Compatibility Guide for PCR and qpcr Cyclers

Peak of Perfection. Made for a faster and easier daily routine: Eppendorf Liquid Handling Consumables

Cleaning and Decontamination of the ept.i.p.s. Box

Eppendorf UVette. Instructions for use

ab Caspase 3, Caspase 8 and Caspase 9 Multiplex Activity Assay Kit (Fluorometric)

BIOO FOOD AND FEED SAFETY. Histamine Enzymatic Assay Kit Manual. Catalog #: Reference #:

Technology that counts

Comparative Analysis of Protein Recovery Rates in Eppendorf LoBind and Other Low Binding Tubes

Eppendorf SmartBlock. Instructions for use

Easy Illumina Nextera DNA FLEX Library Preparation using the epmotion 5075t automated liquid handler

NEW! Your bacteria s favorite! Eppendorf Eporator

Automated Illumina TruSeq DNA PCR-Free library construction with the epmotion 5075t/TMX

TARTARIC ACID (TARTRATE)

The Plus for your lab!

Technology that counts

DEVELOP YOUR LAB, YOUR WAY

stance et Helper Eppendorf Pipet Helper Chemical Resistance

High-throughput Isolation of Genomic DNA From Buccal Swab on the Eppendorf epmotion 5075 VAC

Automated Illumina TruSight HLA v2 Sequencing Panel Library Preparation with the epmotion 5075t

Human IL-1 beta ELISA Kit

Applications Note 228 September 2010

Technology that counts

Micropipetting Basics

Food & Beverage by Eppendorf

For Research Use Only

Get More! Quality Stability Purity: Eppendorf Plates

Comparing the Microlab 600 to Volumetric Glassware and Air Displacement Pipettes. January 2013

Faster Isolation of PBMC Using Ficoll-Paque Plus in the Eppendorf Multipurpose Benchtop Centrifuges 5920 R and 5910 R

Bisphenol A ELISA Kit

Multiple Talents. Eppendorf Temperature Control and Mixing Instruments

MyBioSource.com. This package insert must be read in its entirety before using this product.

Peak of Perfection. Made for a faster and easier daily routine: Eppendorf Liquid Handling Consumables

Microcystin-LR ELISA Kit

Applications Note 164 October 2007

The Value of Mixing. Eppendorf Temperature Control and Mixing Instruments

AF (Total Aflatoxin) ELISA Kit

The kit is a sandwich enzyme immunoassay for in vitro quantitative measurement of GFP in biological agents. Reagents Quantity Reagents Quantity

For the rapid, sensitive and accurate measurement of Urea levels in various samples.

Microcystin-LR ELISA Kit

AFM1 (Aflatoxin M1) ELISA Kit

Growth in Motion. The next evolution in biological shakers the Innova S44i

Rat Brain Derived Neurotrophic Factor (BDNF) ELISA

QuickZyme Hydroxyproline Assay

Automated Illumina TruSeq Stranded Total RNA library construction with the epmotion 5075t/TMX

ab83360 Ammonia Assay Kit (Colorimetric)

Rat Coagulation Factor X (F10) ELISA

This immunoassay kit allows for the in vitro quantitative determination of Aflatoxin M1 concentrations in milk, milk power.

Aflatoxin M1 (AFM1) ELISA Kit

Human anti-myelin associated glycoprotein antibody (MAG) Ab ELISA Kit

cobas c 111 analyzer Big analyzer performance in a small package

Transcription:

APPLICATION NOTE No. 350 I May 2015 Multipette / Repeater M4 allows for fast, precise and sterile liquid transfer in cell culture Nathalie Chandelier¹, Vincent Dufey¹, Muriel Art¹, Diana Hübler² ¹Eppendorf Application Technologies S.A., Namur, Belgium; ²Eppendorf AG, Hamburg, Germany Abstract Pipetting in cell culture needs the consideration of various factors. The most important ones are sterility, accuracy and precision. Liquid handling systems used in cell culture should assure sterile liquid transfer and accurate and precise pipetting results. Commonly air-cushion pipettes in combination with filter tips and pipet controllers in combination with serological pipets are used for liquid handling transfer in cell culture. This application note introduces a third pipetting system suitable for cell culture applications. These are positive displacement dispensers which offer the great advantage of complete aerosol prevention as the piston integrated in the tip of the positive displacement system hermetically seals the sample in the tip from the instrument and thus ensures that no contamination of the instrument or a cross-contamination between different samples will occur. In terms of accuracy and precision positive-displacement dispenser show equivalent results to those obtained with manual or electronic air-cushion pipettes and are obviously suitable for handling cells. In contrary, reproducibility of results will be affected when pipet controllers in combination with serological pipets are used. That highlights that pipet controllers and serological pipets have clearly to be kept for applications which do not require accuracy and precision e.g. transferring larger volumes of e.g. media out of flasks, dishes or roller bottles. Introduction Animal cell culture has become a common laboratory technique and is used for a large range of applications such as vaccines production, cell therapy or cancer research. Furthermore, cell cultures offer excellent model systems for studying basic cell physiology (as aging or metabolic activities) and thus play a crucial role in drug discovery processes [1]. As most applications in cell culture include several pipetting steps, choosing the appropriate liquid handling instrument which fulfils the special needs of the application is essential. There are different factors which need to be considered when talking about pipetting in cell culture. Firstly, as microbiological contamination is the most important concern of the researcher, this is sterility/safety. Sterility is a must in cell culture and all steps in cell culture have to be performed under sterile conditions. Secondly, this is accuracy and precision. Especially when working with small volumes (< 1 ml), a precise and accurate liquid transfer is essential. Last but not least it is time and costs. Depending on the experiment, time is a crucial factor which contributes strongly to the success of an experiment. The time needed for an experiment and its success are furthermore strongly linked to experimental costs.

APPLICATION NOTE I No. 350 I Page 2 For all steps in cell culture the researcher has to decide which of the four mentioned factors is most crucial for his application (mostly you can optimize for two but not for all). Depending on the decision made, the most appropriate liquid handling device should be chosen. Commonly pipet controllers in combination with serological pipets and classical air-cushion pipettes are used for cell biology applications. The disposable plastic serological pipets in combination with pipette controllers are mainly used for the transfer of larger volumes (~ 1 ml to 50 ml) out of flasks, dishes or roller bottles. Here the priority is speed and sterility. Air-cushion pipettes are mainly used for the transfer of smaller volumes (< 1 ml), where the priority mainly lays on precision and speed. As the greatest sources of microbial contamination are aerosols generated during culture manipulation, the use of filter tips is highly recommended to avoid pipette and subsequently, sample contamination. Nevertheless, some studies demonstrated that a 100 % protection against contamination cannot be guaranteed by conventional single-layer filter tips. Indeed, it has been shown that for particles of a diameter between 0.3 µm and 0.7 µm (corresponding to the size of many viruses and bacteria), the filter efficiency can drop to 85 % [2]. Consequently researchers should carefully select the consumable used with air-cushion pipettes and if possible should prefer filter tips with a two-phase filter, such as Eppendorf ep Dualfilter T.I.P.S.. Here a 99.9 % protection against aerosols is assured. An alternative to pipet controllers and air-cushion pipettes are positive displacement dispensers. In terms of sterility these devices offer a significant benefit as a contamination of the instrument or a cross-contamination between different samples via aerosols is completely prevented. This is ensured by a piston which is integrated in the tip of the positive displacement system and hermetically seals the sample in B the tip from the instrument. Furthermore this system allows accurate and precise pipetting results especially when working with liquids whose physical properties differ from those of water. In this Application note, the Eppendorf Multipette/ Repeater M4 Dispenser used in combination with Combitips advanced Biopur has been compared to traditionally used pipetting systems in cell culture. This is to demonstrate the huge advantages offered by Multipette M4 in terms of accuracy and precision needed for many cell culture applications. Materials and Methods Materials Pipetting systems (instruments and consumables) > Eppendorf, Multipette M4 (order no. 4982 000.012) > Eppendorf, Combitips advanced 2.5 ml Biopur (order no. 0030 089.650) > Eppendorf, Combitips advanced 1 ml Biopur (order no. 0030 089.642) > Eppendorf, Research plus pipette, 20-200 µl (order no. 3120 000.054) > Eppendorf, Xplorer pipette, 50-1000 µl (order no. 4861 000.040) > Eppendorf, ep Dualfilter T.I.P.S., 2-100 µl PCR clean/sterile (order no. 0030 077.547) > Eppendorf, ep Dualfilter T.I.P.S., 50-1000 µl PCR clean/ sterile (order no. 0030 077.571) > Eppendorf, Easypet 3 (order no. 4430 000.018) > Eppendorf, Serological Pipets, 1 ml (order no. 0030 127.692) Instrument Calibration > Mettler-Toledo, micro balance Excellence plus XP26PC (Mettler-Toledo, order no. 11106021) > VWR, Water Molecular Biology Grade (order no. 733-1090) > MEM medium supplemented with 10% FBS superior Cell Culture > Human Embryonic Kidney 293 cells (HEK 293) (DSMZ ACC 305), cultivated in MEM medium supplemented with 10% FBS superior > Eppendorf, Cell Culture Flask T-75, TC treated, with filter cap (order no. 0030 711.122)

APPLICATION NOTE I No. 350 I Page 3 Cell Counting > Roche Innovatis, CASY Cell Counter and Analyser, model TT 150 µm (order no. 4 00 06) > Roche Innovatis, CASY ton (order no. 4 30 01) > Roche Innovatis, CASY cups (order no. 4 30 03) WST-1 Colorimetric Assay > Roche Diagnostics, Cell Proliferation Reagent WST-1 (order no. 11 644 807 001) > Eppendorf, Cell Culture Plate, 24-Well, TC treated (order no. 0030 722.116) > Eppendorf, PlateReader AF2200 (order no. 6141 000.002) Methods Instrument Calibration Systematic and random errors were determined by gravimetric method in accordance with the EN ISO 8655 standard [3]. As requested by the norm, tests were carried out in a draught-free room. During testing, relative humidity was above 50 % and temperature was constant. Instruments, consumables and test liquids were equilibrated to the test room for at least 2 hours before starting the test. To determine errors, the test liquid was dispensed ten times into a vessel and weighed. For each condition, three series of ten dispensings were performed. A new consumable was used for each series. The systematic error (inaccuracy) and the random error (imprecision) were determined for each series of 10 measurements. Three values were obtained per condition, from which the average and standard deviation were calculated. Cell Counting Cell number was determined by using the CASY Cell Counter and Analyser. Measurement was performed by suspending 100 µl of cell suspension in 10 ml of CASY ton, an electrolyte developed specifically for cell counting and by aspirating them through a measuring pore. During the measurement process, a pulsed low voltage field is applied to the measuring pore via two platinum electrodes. The measuring pore filled with electrolyte solution represents a defined electrical resistance. During their passage through the measuring pore, cells displace a quantity of electrolyte corresponding to their volume. Since intact cells are reacting as isolators, an increased level of resistance is achieved over the measuring pore. Cell seeding and WST-1 Colorimetric Assay After cell counting, a cell suspension of 1.5x10 6 cells/ml was prepared for cell seeding. From this stock solution, various quantities of cells were seeded into 24-well plates. In order to evaluate the number of viable cells 40 µl of WST-1 (Water Soluble Tetrazolium salt) was added per well. As shown on figure 1, the WST-1 is cleaved to formazan by cellular enzymes. This reduction is largely dependent on the NAD(P)H production in viable cells. Therefore, the amount of formazan dye formed directly correlates to the number of metabolically active cells in the culture. Figure 1: Cleavage of the tetrazolium salt WST-1 to formazan Cell culture plates were incubated with the WST-1 reagent for 3 hours in a humidified atmosphere (37 C, 5 % CO 2 ). After finalizing the incubation time, the plates were mixed for 1 minute in the PlateReader AF2200 and afterwards read at 450 nm with a reference reading at 690 nm. The measured absorbance can be directly correlated to the number of viable cells.

APPLICATION NOTE I No. 350 I Page 4 Results and Discussion Performance evaluation of the used pipetting systems Accuracy and precision of the instruments compared within this study were established by usual gravimetric method in accordance with the EN ISO 8655 norm. The volume tested was 100 µl. For this purpose, each instrument was associated with its dedicated consumable (Multipette/Repeater M4 with Combitips advanced 1 ml, Research plus single-channel pipette with 100 µl tips, Xplorer single-channel pipette with 1000 µl tips and Easypet 3 with serological pipets of 1 ml). For each condition, three series of ten dispensings were performed. As expected, the serological pipet controlled by the Easypet 3 is the less accurate and the less reproducible system of all four systems tested. The volume delivered with this system is systematically higher and a constant and stable dispensing is difficult to acquire. Depending on the application, those poor performances could have an impact on the application result. On the opposite, with mean accuracy and precision values below 0.6 %, air-cushion pipettes and Multipette/Repeater M4 appear as the most reliable systems. Those data obviously demonstrate that an accurate and precise liquid transfer can be guaranteed with a positive-displacement instrument as well as with a traditional air-cushion device. Systematic error (%) 3,0 2,0 1,0 n = 3 Random error (%) 14,0 12,0 1 8,0 6,0 4,0 2,0 n = 3-1,0 Research plus Xplorer Multipette M4 Easypet Research plus Xplorer Multipette M4 Easypet Instrument Instrument Figure 2 and 3: Inaccuracy (Figure 2) and imprecision (Figure 3) at 100 µl measured for the different pipetting system used Impact of the pipetting system on cell counting To evaluate the impact of the pipetting system on cell counting, three systems have been compared: a manual air-cushion pipette (Research plus pipette) with ep Dualfilter T.I.P.S., a positive-displacement system (Multipette/Repeater M4) combined with Combitips advanced and an electronic pipet controller (Easypet 3) associated with serological pipets. The cell number of the HEK 293 cells was determined by using the CASY technology. Measurements were performed by dispensing 100 µl of the cell suspension into 10 ml of CASY ton and aspirating this solution through the measuring pore of the CASY cell counter.

APPLICATION NOTE I No. 350 I Page 5 Table 1: Cell counting results obtained according to pipetting system used to dispense 100 µl of the cell solution (n=30). Pipetting system Mean Cell Number CV Min value Max value Mean Viability n=30 Air-displacement 1.65x10 6 cells/ml 3.0 % 1.52 10 6 cells/ml 1.75 10 6 cells/ml 96.4 % Positive-displacement 1.62x10 6 cells/ml 2.5 % 1.53 10 6 cells/ml 1.69 10 6 cells/ml 96.0 % Pipette Controller 1.50x10 6 cells/ml 6.8 % 1.39 10 6 cells/ml 1.85 10 6 cells/ml 96.2 % As shown in table 1, the level of cell viability is not affected by the pipetting system used as the percentage of viable cells is around 96 % for all conditions assessed. In contrast, the cell count variability is obviously influenced by the instrument used to dispense the cell suspension. Indeed, data indicate that the most precise system is the Multipette/Repeater M4 associated with Combitips advanced while a pipet controller in combination with serological pipets is the least reproducible system. As Research plus pipettes are classically used for cell counting, they are considered as reference instruments. A Fisher test has been applied to define if reproducibility offered by all other systems is significantly different from this reference (data not shown). According to this statistical test, positive-displacement dispenser and air-cushion pipettes induce an equivalent variability of cell counting results while the reproducibility obtained with the pipet controller is significantly lower. Those results can be correlated with previous calibration data and prove that the performance of a pipetting system has an impact on the application. Depending on the pipetting system used the impact is of different magnitude. Impact of the pipetting system on cell seeding Based on the cell counting data, six cell suspensions of 1.5x10 6 cells/ml were prepared by considering the minimal and the maximal counting values obtained for each pipetting system (table 1). Those cell suspensions were used to seed various cell amounts into 24-well plates. Table 2 details the numbers of cells seeded and the corresponding cell suspension volumes. Three pipetting systems were used to dispense increasing numbers of cells: an electronic air-cushion pipette (Xplorer single-channel pipette) used with ep Dualfilter T.I.P.S., a positive-displacement system (Multipette/ Repeater M4) combined with Combitips advanced and an electronic pipet controller (Easypet 3) associated with serological pipets. In every well, the final culture volume has been adjusted to 400 µl with culture media as described in table 2. Four replicates were performed for each condition. Table 2: Number of cells per well and corresponding cell and media volume Number of cells/well Cell volume dispensed Media volume dispensed 0 0 µl 400 µl 75,000 50 µl 350 µl 1500 100 µl 300 µl 3000 200 µl 200 µl 4500 300 µl 100 µl 6000 400 µl 0 µl In order to evaluate the number of viable cells in every well, 40 µl/well of WST-1 (Water Soluble Tetrazolium salt) was added. As shown in figure 1, the WST-1 is cleaved to formazan dye by cellular enzymes. The absorbance of this dye is measured and can directly be correlated to the number of viable cells. Curves obtained are depicted in figures 4 to 6.

APPLICATION NOTE I No. 350 I Page 6 Signal generated by viable cells (OD 450-690 nm) 1,0 0,8 0,6 0,4 0,2 Lowest value Highest value Cell viability (OD 450-690 nm) 1,0 0,8 0,6 0,4 0,2 Lowest value Highest value Cell viability (OD 450-690 nm) 1,0 0,8 0,6 0,4 0,2 Lowest value Highest value 0 150000 300000 450000 600000 Number of cells/well 0 150000 300000 450000 600000 Number of cells/well 0 150000 300000 450000 600000 Number of cells/well Figure 4-6: Signal curves generated by increasing numbers of cells. Three different pipetting systems were used for cell counting as well as cell seeding (air-cushion system, figure 4), (positive-displacement system, figure 5) and (pipet controller, figure 6). These results indicate that using a positive-displacement system, as the Multipette/Repeater M4 in combination with Combitips advanced, for cell counting as well as for cell seeding, guarantees reproducibility of the final result. Curves obtained with the dispenser are similar or even slightly less variable than those obtained with air-cushion instruments. On the opposite, as soon as a less precise instrument as a pipet controller is used, reproducibility of the final results will be affected. That highlights that serological pipets have clearly to be kept for activities which do not require accuracy and precision e.g. transferring larger volumes of e.g. media out of flasks, dishes or roller bottles. On the contrary, because it combines accuracy, precision and contamination prevention, the Multipette/Repeater M4 in combination with Combitips advanced represents a perfect alternative for all routine tasks requiring a liquid handling device in cellular biology labs. Conclusion Liquid handling transfer in cell culture has to fulfill different requirements, among which the most important are sterility/ safety, accuracy and precision. In this study we tested three different pipetting systems, air-cushion pipettes which are commonly used to pipette smaller volumes, pipet controller commonly used for larger volumes of e.g. media and positive-displacement dispenser. We were able to show that serological pipets handled by a pipet controller should be limited to applications which do not demand a high level of reproducibility. We furthermore demonstrated that the Multipette/Repeater M4 combined with Combitips advanced is obviously suitable for handling cells. Performances offered by this pipetting system are equivalent to those obtained with manual or electronic air-cushion pipettes. Moreover, because the Combitips advanced prevent any contact between the sample and the device, the Multipette/Repeater M4 appears as the perfect alternative for scientists particularly concerned by contamination. Literature [1] Nema R, Khare S. An animal cell culture: Advance technology for modern research. Advances in Bioscience and Biotechnology 2012; 3:219-226. [2] Le Rouzic E, Contamination-pipetting: relative efficiency of filter tips compared to Microman positive displacement pipette. Nature methods 2006; 3 Application note. [3] EN ISO 8655, Parts 1-6: Piston-operated volumetric apparatus. ISO 2002.

APPLICATION NOTE I No. 350 I Page 7 Ordering information Description Order no. international Order no. North America Multipette M4 incl. holder (for wall and/or pipette carousel) 4982 000.012 Repeater M4 Starter Kit, Repeater M4, Combitip Rack, 4982000322 Combitip assortment pack Multipette 4987 000.010 Repeater E3 4987000118 Research plus pipette 20-200 µl 3120 000.054 3120000054 Xplorer pipette 50-1000 µl 4861 000.040 4861000732 ep Dualfilter T.I.P.S. 2-100 µl PCR clean/sterile 0030 077.547 022491296 ep Dualfilter T.I.P.S. 50-1000 µl PCR clean/sterile 0030 077.571 022491253 Easypet 3 4430 000.018 4430000026 Combitips advanced in Eppendorf quality 0.1 ml 0030 089.405 5392070020 0.2 ml 0030 089.413 5392070011 0.5 ml 0030 089.421 0030089421 1mL 0030 089.430 0030089430 2.5 ml 0030 089.448 0030089448 5 ml 0030 089.456 0030089456 10 ml 0030 089.464 0030089464 25 ml 0030 089.472 0030089472 50 ml 0030 089.480 0030089480 Combitips advanced PCR clean 0.1 ml 0030 089.766 0030 089766 0.2 ml 0030 089.774 0030 089774 0.5 ml 0030 089.782 0030 089782 1 ml 0030 089.790 0030 089790 2.5 ml 0030 089.804 0030 089804 5 ml 0030 089.812 0030 089812 10 ml 0030 089.820 0030 089820 25 ml 0030 089.839 0030 089839 50 ml 0030 089.847 0030 089847 Combitips advanced Biopur 0.1 ml 0030 089.618 0030 089618 0.2 ml 0030 089.626 0030 089626 0.5 ml 0030 089.634 0030 089634 1 ml 0030 089.642 0030 089642 2.5 ml 0030 089.650 0030 089650 5 ml 0030 089.669 0030 089669 10 ml 0030 089.677 0030 089677 25 ml 0030 089.685 0030 089685 50 ml 0030 089.693 0030 089693 25 ml adapter (1 pc.) 0030 089.715 0030 089715 50 ml adapter (1 pc.) 0030 089.723 0030 089723 25 ml adapter (7 pc.), Biopur 0030 089.731 0030 089731 50 ml adapter (7 pc.), Biopur 0030 089.740 0030 089740 Combitip Rack 0030 089.758 0030 089758 Serological Pipets, 1 ml 0030 127.692 0030127692 Serological Pipets, 2 ml 0030 127.706 0030 127706 Serological Pipets, 5 ml 0030 127.714 0030 127714 Serological Pipets, 10 ml 0030 127.722 0030 127722 Serological Pipets, 25 ml 0030 127.730 0030 127730 Serological Pipets, 50 ml 0030 127.749 0030 127749

APPLICATION NOTE I No. 350 I Page 8 epservices for premium performance We Care for Your Pipettes Regular maintenance, calibration and adjustment ensure that your pipettes continue to generate reproducible results. We offer a range of service options, from quick economical calibration to GLP /GMP custom-designed, calibration services according to national and international standards. More details and local offers: www.eppendorf.com/epservices Video «Eppendorf Pipette Service»: www.eppendorf.com/pipette-video Your local distributor: www.eppendorf.com/contact Eppendorf AG 22331 Hamburg Germany eppendorf@eppendorf.com www.eppendorf.com www.eppendorf.com CASY is a registered trademark of Roche Innovatis AG, Germany. Roche is a registered trademark of Hoffmann-La Roche Inc., USA. Mettler-Toledo is a registered trademark of Mettler-Toledo Inc., USA. Eppendorf, the Eppendorf logo, Eppendorf Multipette /Repeater, Eppendorf Combitips advanced, Eppendorf Biopur, Eppendorf Research plus, Eppendorf Xplorer, ep Dualfilter T.I.P.S. and Eppendorf Easypet are registered trademarks of Eppendorf AG, Hamburg, Germany. All rights reserved, including graphics and images. Copyright 2015 by Eppendorf AG, Hamburg, Germany.