Installation Contactors ISU-xxx ISM-xxx Installation contactors are used in building technology switching cabinets of apartment blocks, office buildings, restaurants and hotels, shopping centres and hospitals as well as in industrial applications, production sites, logistics and warehouse technology for example. They are used here for automatic activation of electrical devices and units, alternating current and three-phase current motors, pumps, air conditioning systems, electric heaters and lighting technology or contacts Normally closed and / or normally open contacts High contact load 0A, A, 0A or A per contact Protective wiring Varistor for overvoltage protection Hum-free operation The built-in rectifier enables hum-free operation with direct and alternating current Special version ISM-xxx Additional manual operation possible A = automatic activation 0 = control voltage always off, no activation possible I = manual switch-on, the switch jumps automatically to the A position when the control voltage is applied Sealing cover Spacer ISD- ISP-0 ISP- ISP-0 Relmatic AG - Zuerichstrasse a - CH 0 Bruettisellen - www..com
Technical data ISU-0 ISM-0 ISU- ISM- ISU-0 Rated insulating voltage U i 0 V 0 V 0 V 0 V Thermal limit current I th (in AC) 0 A A 0 A A Current overload capacity (0s) A A A 0 A Switching capacity Operation current AC-, 00 V, phases x kw kw 0 kw ISU- Operation current AC-, 0 V kw, phase 9 kw, phases kw, phases kw, phases Operating current AC-, 00 V, phases x kw kw kw Operating current AC-, 0V. kw, phase only NOC. kw, phases. kw, phases. kw, phases Operating current AC-a, 00 V, phases x kw kw 0 kw Operating current AC-a, 0V kw, phase 9 kw, phases kw, phases kw, phases Operating current AC-b, 00 V, phases x kw kw kw Operating current AC-b, 0V. kw, phase only NOC. kw, phases. kw, phases. kw, phases Operating current AC-, 00 V, Phase A A A A Operating current AC-, 0 V, Phase A A A A Operating current DC U e = V 0 A A 0 A A Operating current DC U e = 0 V A A A A Operating current DC U e = 0 V 0. A 0. A. A. A Max. switching frequency at max. load 00 / h 00 / h 00 / h 00 / h Electrical life 0/00 V AC- resistive load 0. x 0 0. x 0 0. x 0 0. x 0 AC- motor load 0. x 0 0. x 0 0. x 0 0. x 0 AC-a high-pressure s 0. x 0 / 0 μf 0. x 0 / μf 0. x 0 / 0 μf 0. x 0 / 0 μf AC-b filament s 0. x 0 / kw 0. x 0 / kw 0. x 0 / kw 0. x 0 / kw AC-a resistance for household appliances 0. x 0 0. x 0 0. x 0 0. x 0 AC-b motor load for household appliances 0. x 0 0. x 0 0. x 0 0. x 0 Minimum load V, 0 ma V, 0 ma V, 0 ma V, 00 ma Short-circuit protection with type M fuse 0 A A A 0 A Co-ordination type EN 09-- Insulation strength kv kv kv kv Contacts - max. wire cross-section Single wire conductor 0 mm 0 mm mm mm Multi-wire conductor (strands) mm mm mm mm Max. torque. Nm. Nm. Nm. Nm Coil - max. wire cross-section Single wire conductor. mm. mm. mm. mm Multi-wire conductor (strands). mm. mm. mm. mm Max. torque 0. Nm 0. Nm 0. Nm 0. Nm Control Coil control voltage AC/DC V / V 0 / 0 V V / V 0 / 0 V V / V 0 / 0 V V / V 0 / 0 V Coil reference power +/- 0 %. VA /. W. VA /. W VA / W VA / W Parallel installation max. contactors* max. contactors* max. contactors* max. contactors* Ambient temperature Max. heating during operation Operation: - C + C, Transport and storage: -0 C +0 C Front: 0 K, Side: 0 K Weight 0 g 0 g 0 g 0 g Dimensions.xx0 mm xx0 mm.xx0 mm.xx0 mm Standards IEC 09--, IEC 09--, IEC 09, EN 09--, EN 09--, EN 09, VDE 00 Auxiliary contact block ISH-0 ISH-0 ISH- Type of contact NOC NCC NOC, NCC Rated operational voltage U e 0 V 0 V 0 V Rated operational current AC- I e A A A Minimum load V, ma V, ma V, ma Terminal capacity rigid and flexible. mm. mm. mm * When several contactors are installed next to each other, a spacer must be fitted between every second device. Relmatic AG - Zuerichstrasse a - CH 0 Bruettisellen - www..com
Contact variants ISU-0-0 / ISM-0-0 ISU-0- / ISM-0- ISU-0-0 / ISM-0-0 R R R R ISU--0 / ISM--0 ISU-- / ISM-- R R ISU-- / ISM-- ISU--0 / ISM--0 R R R R R R R R R R ISU-0-0 ISU-0- R + - ISU-0- R R + ISU-0-0 R R R R R - R R R ISU--0 ISU-- ISU-- R R R R Relmatic AG - Zuerichstrasse a - CH 0 Bruettisellen - www..com
Number of s on an installation contactor contact Lighting type Power (W) Current (A) ISU-0 ISU- ISU-0 ISU- ISM-0 ISM- Filament 0 0. 00 0. 0 0 0 0 0 0 00 0. 0 0 0 0 0 00. 0 000. Fluorescent 0. 90 0 0. 90 0 0. 0 9 0 0. 0 Fluorescent with duo-circuit Fluorescent parallel-compensated Fluorescent with electronic ballast (EB) Uncompensated mercury vapour high-pressure s mercury vapour highpressure s 0. x 0 x 0 x 00 x 0 x 0 x 0 0. x x x x x x 0. x x x x 9 x x 0. x 0 x x 0 x 0 x 0 x 0. 0. 0.0 0. X 0.09 00 0 X 0. 0 0 X 0. 9 0 9 X 0. 0 0 X 0. 0 0 X 0.9 9 9 0 0. 0 0.0 0 9 0. 9 0 9 9 0. 0 00. 0 00. 000. 0 0. 0 0. 0. 0. 00.9 9 00. - - - - 000. - - - - Relmatic AG - Zuerichstrasse a - CH 0 Bruettisellen - www..com
Number of s on an installation contactor contact Lighting type Uncompensated halogen metal vapour halogen metal vapour Uncompensated sodium vapour high-pressure sodium vapour highpressure Uncompensated sodium vapour low-pressure sodium vapour lowpressure Power (W) Current (A) ISU-0 ISU- ISU-0 ISU- ISM-0 ISM- 0. 0 0 0 0 0. 0 0 00. 9 000 9. 000. - - - - 0. 0 0 0. 0 0. 0. - 9-00. - - 000. - - - - 000. - - - - 0. 0 0 00. 000 0. - - 0 0. 0. - 0-00. - - - - 000. - - - - 0. 90. 9 0 9. 9 0 9 90. 9. 0 0. 0 0. 0. 0. 90 0. 0.9 - - - - 0 - - - - - Relmatic AG - Zuerichstrasse a - CH 0 Bruettisellen - www..com
Order data Device Order no. Installation contactor NOC 0 A, coil V AC/DC ISU-0-0/V Installation contactor NOC 0 A, coil 0 V AC/DC ISU-0-0/0V Installation contactor NOC, NCC 0 A, coil V AC/DC ISU-0-/V Installation contactor NOC, NCC 0 A, coil 0 V AC/DC ISU-0-/0V Installation contactor NCC 0 A, coil V AC/DC ISU-0-0/V Installation contactor NCC 0 A, coil 0 V AC/DC ISU-0-0/0V Installation contactor NOC A, coil V AC/DC ISU--0/V Installation contactor NOC A, coil 0 V AC/DC ISU--0/0V Installation contactor NOC, NCC A, coil V AC/DC ISU--/V Installation contactor NOC, NCC A, coil 0 V AC/DC ISU--/0V Installation contactor NOC, NCC A, coil V AC/DC ISU--/V Installation contactor NOC, NCC A, coil 0 V AC/DC ISU--/0V Installation contactor NCC A, coil V AC/DC ISU--0/V Installation contactor NCC A, coil 0 V AC/DC ISU--0/0V Installation contactor NOC 0 A, coil V AC/DC ISU-0-0/V Installation contactor NOC 0 A, coil 0 V AC/DC ISU-0-0/0V Installation contactor NOC, NCC 0 A, coil V AC/DC ISU-0-/V Installation contactor NOC, NCC 0 A, coil 0 V AC/DC ISU-0-/0V Installation contactor NOC, NCC 0 A, coil V AC/DC ISU-0-/V Installation contactor NOC, NCC 0 A, coil 0 V AC/DC ISU-0-/0V Installation contactor NCC 0 A, coil V AC/DC ISU-0-0/V Installation contactor NCC 0 A, coil 0 V AC/DC ISU-0-0/0V Installation contactor NOC A, coil V AC/DC ISU--0/V Installation contactor NOC A, coil 0 V AC/DC ISU--0/0V Installation contactor NOC, NCC A, coil V AC/DC ISU--/V Installation contactor NOC, NCC A, coil 0 V AC/DC ISU--/0V Installation contactor NOC, NCC A, coil V AC/DC ISU--/V Installation contactor NOC, NCC A, coil 0 V AC/DC ISU--/0V Installation contactor NOC 0 A, coil V AC/DC, additional manual operation ISM-0-0/V Installation contactor NOC 0 A, coil 0 V AC/DC, additional manual operation ISM-0-0/0V Installation contactor NOC, NCC 0 A, coil V AC/DC, additional manual operation ISM-0-/V Installation contactor NOC, NCC 0 A, coil 0 V AC/DC, additional manual operation ISM-0-/0V Installation contactor NCC 0 A, coil V AC/DC, additional manual operation ISM-0-0/V Installation contactor NCC 0 A, coil 0 V AC/DC, additional manual operation ISM-0-0/0V Installation contactor NOC A, coil V AC/DC, additional manual operation ISM--0/V Installation contactor NOC A, coil 0 V AC/DC, additional manual operation ISM--0/0V Installation contactor NOC, NCC A, coil V AC/DC, additional manual operation ISM--/V Installation contactor NOC, NCC A, coil 0 V AC/DC, additional manual operation ISM--/0V Installation contactor NOC, NCC A, coil V AC/DC, additional manual operation ISM--/V Installation contactor NOC, NCC A, coil 0 V AC/DC, additional manual operation ISM--/0V Installation contactor NCC A, coil V AC/DC, additional manual operation ISM--0/V Installation contactor NCC A, coil 0 V AC/DC, additional manual operation ISM--0/0V Auxiliary contact block NOC A ISH-0 Auxiliary contact block NCC A ISH-0 Auxiliary contact block NOC, NCC A ISH- Sealing cover For sealing the connecting terminals, module wide ISP-0 Sealing cover For sealing the connecting terminals, module wide ISP- Sealing cover For sealing the connecting terminals, module wide ISP-0 Spacer To prevent overheating when connecting the contactors in rows, 9 mm ISD- *** Other versions and coil voltages on request *** Subject to changes! 0.0 Relmatic AG - Zuerichstrasse a - CH 0 Bruettisellen - www..com