Seismic design of bridges

Similar documents
EUROCODE EN SEISMIC DESIGN OF BRIDGES

Design of Earthquake-Resistant Structures

Seismic design of bridges

Sabah Shawkat Cabinet of Structural Engineering Walls carrying vertical loads should be designed as columns. Basically walls are designed in

Seminar Bridge Design with Eurocodes

INELASTIC RESPONSES OF LONG BRIDGES TO ASYNCHRONOUS SEISMIC INPUTS

CHAPTER 5. T a = 0.03 (180) 0.75 = 1.47 sec 5.12 Steel moment frame. h n = = 260 ft. T a = (260) 0.80 = 2.39 sec. Question No.

Module 6. Approximate Methods for Indeterminate Structural Analysis. Version 2 CE IIT, Kharagpur

file:///d /suhasini/suha/office/html2pdf/ _editable/slides/module%202/lecture%206/6.1/1.html[3/9/2012 4:09:25 PM]

Objectives. In this section you will learn the following. Rankine s theory. Coulomb s theory. Method of horizontal slices given by Wang (2000)

Evaluation of dynamic behavior of culverts and embankments through centrifuge model tests and a numerical analysis

Chapter 6 Seismic Design of Bridges. Kazuhiko Kawashima Tokyo Institute of Technology

3.4 Analysis for lateral loads

MECHANICS OF STRUCTURES SCI 1105 COURSE MATERIAL UNIT - I

D : SOLID MECHANICS. Q. 1 Q. 9 carry one mark each. Q.1 Find the force (in kn) in the member BH of the truss shown.

ENERGY DIAGRAM w/ HYSTERETIC

TABLE OF CONTENTS SECTION TITLE PAGE 2 PRINCIPLES OF SEISMIC ISOLATION OF BRIDGES 3

GEOTECHNICAL ENGINEERING ECG 503 LECTURE NOTE ANALYSIS AND DESIGN OF RETAINING STRUCTURES

Bridge deck modelling and design process for bridges

Influence of residual stresses in the structural behavior of. tubular columns and arches. Nuno Rocha Cima Gomes

Structural Steelwork Eurocodes Development of A Trans-national Approach

DEFORMATION CAPACITY OF OLDER RC SHEAR WALLS: EXPERIMENTAL ASSESSMENT AND COMPARISON WITH EUROCODE 8 - PART 3 PROVISIONS

Finite Element Modelling with Plastic Hinges

Nonlinear static analysis PUSHOVER

Inelastic shear response of RC coupled structural walls

STRUCTURAL ANALYSIS CHAPTER 2. Introduction

M.S Comprehensive Examination Analysis

Pushover Seismic Analysis of Bridge Structures

DYNAMIC CENTRIFUGE TEST OF PILE FOUNDATION STRUCTURE PART TWO : BEHAVIOR OF STRUCTURE AND GROUND DURING EXTREME EARTHQUAKE CONDITIONS

Practical Design to Eurocode 2

1. ARRANGEMENT. a. Frame A1-P3. L 1 = 20 m H = 5.23 m L 2 = 20 m H 1 = 8.29 m L 3 = 20 m H 2 = 8.29 m H 3 = 8.39 m. b. Frame P3-P6

3. Stability of built-up members in compression

LATERAL EARTH PRESSURE AND RETAINING STRUCTURES

Effective stress analysis of pile foundations in liquefiable soil

Chapter 4 Seismic Design Requirements for Building Structures

Seismic Pushover Analysis Using AASHTO Guide Specifications for LRFD Seismic Bridge Design

five Mechanics of Materials 1 ARCHITECTURAL STRUCTURES: FORM, BEHAVIOR, AND DESIGN DR. ANNE NICHOLS SUMMER 2017 lecture

Harmonized European standards for construction in Egypt

STATIC NONLINEAR ANALYSIS. Advanced Earthquake Engineering CIVIL-706. Instructor: Lorenzo DIANA, PhD

EAS 664/4 Principle Structural Design

Influence of the Plastic Hinges Non-Linear Behavior on Bridges Seismic Response

CE5510 Advanced Structural Concrete Design - Design & Detailing of Openings in RC Flexural Members-

Vertical acceleration and torsional effects on the dynamic stability and design of C-bent columns

Lecture-09 Introduction to Earthquake Resistant Analysis & Design of RC Structures (Part I)

EXAMPLE OF PILED FOUNDATIONS

Force Based Design Fundamentals. Ian Buckle Director Center for Civil Engineering Earthquake Research University of Nevada, Reno

Eurocode 8 Part 3: Assessment and retrofitting of buildings

Soil-Structure Interaction in Nonlinear Pushover Analysis of Frame RC Structures: Nonhomogeneous Soil Condition

GATE SOLUTIONS E N G I N E E R I N G

Chapter Objectives. Copyright 2011 Pearson Education South Asia Pte Ltd

THE EC3 CLASSIFICATION OF JOINTS AND ALTERNATIVE PROPOSALS

QUESTION BANK SEMESTER: III SUBJECT NAME: MECHANICS OF SOLIDS

Ph.D. Preliminary Examination Analysis

Lecture-08 Gravity Load Analysis of RC Structures

Civil Engineering Design (1) Design of Reinforced Concrete Columns 2006/7

Structural Steelwork Eurocodes Development of A Trans-national Approach

Nonlinear pushover analysis for pile foundations

Lap splice length and details of column longitudinal reinforcement at plastic hinge region

Seismic Design of New R.C. Structures

Influence of column web stiffening on the seismic behaviour of beam-tocolumn

Influence of cracked inertia and moment-curvature curve idealization on pushover analysis

PLATE GIRDERS II. Load. Web plate Welds A Longitudinal elevation. Fig. 1 A typical Plate Girder

AN IMPORTANT PITFALL OF PSEUDO-STATIC FINITE ELEMENT ANALYSIS

External Pressure... Thermal Expansion in un-restrained pipeline... The critical (buckling) pressure is calculated as follows:

ROSESCHOOL ANALYSIS OF CODE PROCEDURES FOR SEISMIC ASSESSMENT OF EXISTING BUILDINGS: ITALIAN SEISMIC CODE, EC8, ATC-40, FEMA356, FEMA440

ΙApostolos Konstantinidis Diaphragmatic behaviour. Volume B

Where and are the factored end moments of the column and >.

LATERAL STABILITY OF BEAMS WITH ELASTIC END RESTRAINTS

Plastic design of continuous beams

Module 3. Analysis of Statically Indeterminate Structures by the Displacement Method

Nonlinear Analysis of Reinforced Concrete Bridges under Earthquakes

QUESTION BANK DEPARTMENT: CIVIL SEMESTER: III SUBJECT CODE: CE2201 SUBJECT NAME: MECHANICS OF SOLIDS UNIT 1- STRESS AND STRAIN PART A

PLAT DAN CANGKANG (TKS 4219)

Chapter 2: Rigid Bar Supported by Two Buckled Struts under Axial, Harmonic, Displacement Excitation..14

Seismic Performance of RC Building Using Spectrum Response and Pushover Analyses

Displacement-based methods EDCE: Civil and Environmental Engineering CIVIL Advanced Earthquake Engineering

THEME IS FIRST OCCURANCE OF YIELDING THE LIMIT?

Mechanical Properties of Materials

Design of AAC wall panel according to EN 12602

DYNAMIC ANALYSIS OF PILES IN SAND BASED ON SOIL-PILE INTERACTION

Annex - R C Design Formulae and Data

Entrance exam Master Course

ANALYSIS OF LATERALLY LOADED FIXED HEADED SINGLE FLOATING PILE IN MULTILAYERED SOIL USING BEF APPROACH

CAPACITY DESIGN FOR TALL BUILDINGS WITH MIXED SYSTEM

5.4.3 Centre of stiffness and elastic displacements of the diaphragm

A METHOD OF LOAD INCREMENTS FOR THE DETERMINATION OF SECOND-ORDER LIMIT LOAD AND COLLAPSE SAFETY OF REINFORCED CONCRETE FRAMED STRUCTURES

Prof. A. Meher Prasad. Department of Civil Engineering Indian Institute of Technology Madras

FIS Specifications for Flex Poles (Edition May 2008) Original Text: German

BI-DIRECTIONAL SEISMIC ANALYSIS AND DESIGN OF BRIDGE STEEL TRUSS PIERS ALLOWING A CONTROLLED ROCKING RESPONSE

COLUMN INTERACTION EFFECT ON PUSH OVER 3D ANALYSIS OF IRREGULAR STRUCTURES

Design of Reinforced Concrete Beam for Shear

NON-LINEAR ANALYSIS OF SOIL-PILE-STRUCTURE INTERACTION UNDER SEISMIC LOADS

Appraisal of Soil Nailing Design

Seismic Assessment of a RC Building according to FEMA 356 and Eurocode 8

NUMERICAL EVALUATION OF THE ROTATIONAL CAPACITY OF STEEL BEAMS AT ELEVATED TEMPERATURES

Dynamic Response of EPS Blocks /soil Sandwiched Wall/embankment

SHEET PILE WALLS. Mehdi Mokhberi Islamic Azad University

Shear Behaviour of Fin Plates to Tubular Columns at Ambient and Elevated Temperatures

Guidelines on Foundation Loading and Deformation Due to Liquefaction Induced Lateral Spreading

CHAPTER 6: ULTIMATE LIMIT STATE

Transcription:

NATIONAL TECHNICAL UNIVERSITY OF ATHENS LABORATORY FOR EARTHQUAKE ENGINEERING Seismic design of bridges Lecture 3 Ioannis N. Psycharis

Capacity design Purpose To design structures of ductile behaviour ensuring the hierarchy of strengths of the various structural components necessary for leading to the intended configuration of plastic hinges and for avoiding brittle failure modes. Design procedure Use capacity design effects : For the design of all members intended to remain elastic Against all brittle modes of failure. Definition Capacity design effects result from equilibrium conditions at the intended plastic mechanism, when all flexural hinges have developed their flexural resistance including overstrength. I. N. Psycharis Seismic design of bridges 2

Capacity design is applied: Capacity design For the design of sections that must remain within the elastic range (e.g. deck). For the design of all members against non-ductile failure modes (shear of members and shear of joints adjacent to plastic hinges). For the design of the foundation (except of pile foundation, where plastic hinges are allowed). For the design of seismic stoppers and for bearings, links and holding-down devices used for securing structural integrity. The capacity design effects need not be taken greater than those resulting from the design seismic combination where the design effects A Ed are multiplied by the q factor used. I. N. Psycharis Seismic design of bridges 3

Capacity design Overstrength moment of a section where γ 0 M 0 = γ 0 M Rd = overstrength factor for concrete members: γ 0 = 1,35 (EC8 part 2) = 1,40 (E39/99) M Rd = design flexural strength of the section, in the selected direction and sense, based on the actual section geometry and reinforcement Piers with elastomeric bearings In bridges intended to have ductile behaviour, in the case of piers with elastomeric bearings where no plastic hinges are intended to form, the capacity design effects shall be calculated on the basis of the maximum deformation of the elastomeric bearings and a 30% increase of the bearing stiffness. I. N. Psycharis Seismic design of bridges 4

Calculation of capacity design effects The following procedure shall be applied for each of the two horizontal directions of the design seismic action. Step 1 Calculation of the design flexural strengths M Rd and of the overstrength moments M 0 of the sections of the intended plastic hinges, corresponding to the selected sense and direction of the seismic action (A E ). The strengths shall be based on the actual dimensions of the cross-sections and the final amount of longitudinal reinforcement. The calculation shall consider the interaction with the axial force and eventually with the bending moment in the other direction, both resulting from the combination G "+ A E where G is the sum of the permanent actions (gravity loads and posttensioning) and A E is the design seismic action. I. N. Psycharis Seismic design of bridges 5

Calculation of capacity design effects Example Permanent actions G: top: Μ x-x,t =-20 KNm M y-y,t =-120 KNm N t =3000 KN bottom: Μ x-x,b =30 KNm M y-y,b =150 KNm N b =3500 KN shear: V x =27 KN -120 27 27 3000-20 3500 150 y x y x 30 10,0 Seismic action A E : top: Μ x-x,t =-300 KNm M y-y,t =-1200 KNm N t =40 KN bottom: Μ x-x,b =450 KNm M y-y,b =1500 KNm N b =40 KN shear: V x =270 KN 40 270-1200 -300 40 270 1500 y x y x 450 10,0 I. N. Psycharis Seismic design of bridges 6

Calculation of capacity design effects Example (cont d) The design flexural strengths (Μ Rd,y-y ) are calculated considering the interaction with the axial force and the bending moment in the other direction: top: Ν t = 3000+40 = 3040 KN M x-x,t = -20-300 = -320 KNm bottom: Ν b = 3500+40 = 3540 KN M x-x,b = 30+450 = 480 KNm Let us assume that, for these values and the actual reinforcement, the resulting values are: top: M Rd,t = 1400 KNm bottom: M Rd,b = 1800 KNm The corresponding overstrength moments are (for γ 0 = 1,40): top: M 0,t = 1.40 1400 = 1960 KNm bottom: M 0,b = 1.40 1800 = 2520 KNm 2520 1800 1400 1960 10,0 I. N. Psycharis Seismic design of bridges 7

Step 2 Calculation of capacity design effects Calculation of the variation of action effects ΔA C of the plastic mechanism, caused by the increase of the moments of the plastic hinges (ΔM), from the values due to the permanent actions (M G ) to the moment overstrength of the sections (M 0 ). ΔM = γ 0 M Rd M G The effects ΔA C conditions. Example (cont d): may in general be estimated from equilibrium top: ΔM t = 1960-120 = 1840 KNm bottom: ΔM b = 2520-150 = 2370 KNm The corresponding variation of the shear force is: ΔV C 1840 2370 10 421 KN I. N. Psycharis Seismic design of bridges 8

Step 3 Calculation of capacity design effects The final capacity design effects A C shall be obtained by superimposing the variation ΔA C to the permanent action effects F G : A C = A G + ΔA C Example (cont d): Capacity design shear: V C = 27+421 = 448 KN Simplification When the bending moment due to the permanent actions at the plastic hinge is negligible compared to the moment overstrength of the section (M G << γ 0 M Rd ), the effects ΔA C can be directly estimated from the effects A E of the design earthquake action. For example, for cantilever piers, the capacity design shear is: V C ΔV C γ0 M M E Rd V E I. N. Psycharis Seismic design of bridges 9

Earth pressure on abutments and retaining walls Seismic coefficients Horizontal: Vertical: where k h = α S/r k v = 0,5 k h α = a g /g (a g = design ground acceleration on ground type A) S = soil coefficient r = coefficient that depends on the amount of permanent displacement which is both acceptable and actually permitted by the adopted structural solution Type of retaining structure r Free gravity walls that can accept a displacement up to d r = 300 α S (mm) 2,0 Free gravity walls that can accept a displacement up to d r = 200 α S (mm) 1,5 Flexural reinforced concrete walls, anchored or braced walls, reinforced concrete walls founded on vertical piles, restrained basement walls and bridge abutments 1,0 I. N. Psycharis Seismic design of bridges 10

Earth pressure on abutments and retaining walls Flexible abutments and walls Total pressure (static + dynamic): 1 2 Ed γs (1 kv) K H 2 where H = wall height K = earth pressure coefficient. It may be computed from the Mononobe Okabe formula kv = vertical seismic coefficient γ s = specific weight of the soil H p d = γ s (1 k v ) K H The point of application is considered at height equal to 0,4H. I. N. Psycharis Seismic design of bridges 11

Earth pressure on abutments and retaining walls Rigid abutments and walls According to Eurocode 8-part 5: H Neutral static earth pressure 1 2 E0 γs K0 H 2 where K 0 = 1 sinφ p st = γ s K 0 H Additional pressure (dynamic): ΔE d α S γ s H The point of application may be taken at mid-height 2 H p d = α S γ s H I. N. Psycharis Seismic design of bridges 12

Earth pressure on abutments and retaining walls Rigid abutments and walls According to E39/99: Neutral static earth pressure E 0 H Two cases for the additional (dynamic) pressure: Limited flexible walls: Uniform distribution of pressure: p d 0,75 α γ s H p d = 0,75 α γ s H p d = 1,5 α S γ s H Non-deformable walls: Top: Bottom: p p d d 1,50 α γ 0,50 α γ s s H H H p d = 0,5 α S γ s H I. N. Psycharis Seismic design of bridges 13

Abutments flexibly connected to the deck The following actions, assumed to act in phase, should be taken into account: Earth pressures (flexible abutments) When the earth pressures are determined on the basis of an acceptable displacement of the abutment (r>1), it should be ensured that this displacement can actually take place before a potential failure of the abutment itself occurs. For this reason, the body of the abutment is designed using the seismic part of the earth pressure increased by 30%. Inertia forces acting on the mass of the abutment and on the mass of earthfill lying over its foundation determined using the design ground acceleration a g. Actions from the bearings determined: From capacity design effects if a ductile behaviour has been assumed for the bridge. From the reaction on the bearings resulting from the seismic analysis if the bridge is designed for q = 1,0. I. N. Psycharis Seismic design of bridges 14

Abutments rigidly connected to the deck The following actions should be taken into account: Inertia forces acting on the mass of the structure which may be estimated using the Fundamental Mode Method. A behaviour factor q = 1,5 shall be used. Abutments buried in strong soils for more than 80% of their height can be considered as fully locked-in. In that case, q = 1 shall be used and the inertia forces are determined on the basis of the design ground acceleration a g. Static earth pressures acting on both abutments (E 0 ). Additional seismic earth pressures ΔE d = E d E 0. The pressures ΔEd are assumed to act in the same direction on both abutments. Reactions on the passive side may be taken into account, estimated on the basis of horizontal soil moduli corresponding to the specific geotechnical conditions. I. N. Psycharis Seismic design of bridges 15

Resistance verification of concrete sections In general, verifications of shear resistance shall be carried out in accordance with par. 6.2 of EC 2 with some additional rules. For the flexural resistance of sections, the following conditions shall be satisfied Structures of limited ductile behaviour (q 1,5) E d R d E d = the design action effect under the seismic load combination including second order effects R d = the design flexural resistance of the section. I. N. Psycharis Seismic design of bridges 16

Resistance verification of concrete sections Structures of ductile behaviour Flexural resistance of sections of plastic hinges: M Ed M Rd M Ed = the design moment under the seismic load combination, including second order effects M Rd = the design flexural resistance of the section. Flexural resistance of sections outside the region of plastic hinges: M C M Rd M C = the capacity design moment M Rd = the design resistance of the section, taking into account the interaction of the corresponding design effects (axial force and when applicable the bending moment in the other direction). I. N. Psycharis Seismic design of bridges 17

Minimum overlap length At supports, where relative displacement between supported and supporting members is intended under seismic conditions, a minimum overlap length, L ov, shall be provided, which may be estimated as: L ov = L m + d eg + d es where: L m = the minimum support length securing the safe transmission of the vertical reaction with L m 40 cm. d eg = the effective displacement of the two parts due to differential seismic ground displacement, which can be estimated from the procedure given in the following. d es = the effective seismic displacement of the support due to the deformation of the structure, which can be estimated from the procedure given in the following. I. N. Psycharis Seismic design of bridges 18

Minimum overlap length Calculation of d eg where: d eg = L eff v g /c a 2 d g L eff = the effective length of deck, taken as the distance from the deck joint in question to the nearest full connection of the deck to the substructure. full connection means a connection of the deck to a substructure member, either monolithically or through fixed bearings or seismic links. v g = peak ground velocity, estimated from the design ground acceleration ag using the relation: v g = 0,16 S T C a g. c a = apparent phase velocity of the seismic waves in the ground. d g = design value of the peak ground displacement. I. N. Psycharis Seismic design of bridges 19

Minimum overlap length Calculation of d es For decks connected to piers either monolithically or through fixed bearings, acting as full seismic links: des = ded, where ded is the total longitudinal design seismic displacement. For decks connected to piers or to an abutment through seismic links with slack equal to s: d es = d Ed + s. In the case of an intermediate separation joint between two sections of the deck, L ov should be estimated by taking the square root of the sum of the squares of the values calculated for each of the two sections of the deck. In the case of an end support of a deck section on an intermediate pier, L ov should be estimated as above and increased by the maximum seismic displacement of the top of the pier d E. I. N. Psycharis Seismic design of bridges 20