Title: ASML Stepper Semiconductor & Microsystems Fabrication Laboratory Revision: B Rev Date: 12/21/2010

Similar documents
Title: ASML PAS 5500 Job Creation Semiconductor & Microsystems Fabrication Laboratory Revision: D Rev Date: 09/20/2012

R I T. Title: GCA Stepper Operations. Semiconductor & Microsystems Fabrication Laboratory Revision: F Rev Date: 08/09/ SCOPE

Figure 1 below shows the generic process flow of an LELE method of double patterning.

0. Table of contents. Author: Jaap Snijder

Microsystems Technology Laboratories i-stepperthursday, October 27, 2005 / site map / contact

STANDARD: SPECIFICATION FOR PROTECTIVE ENCLOSURE AND CARRIER SYSTEMS USED TO TRANSPORT AND STORE ( INCH EUV RETICLES

Visual Test Light Scattering Reticle. Users Guide

GCA AS200 Job Preparation

ON SITE SYSTEMS Chemical Safety Assistant

A Guide to Reticle Design on the Autostep 200 Edward Tang 6/4/04

RECON. How to Setup the Telescope to Observe. This guide will show you how to setup your telescope for observing. Written By: Brittany McCrigler

Photolithography II ( Part 1 )

In-Solution Digestion: Multi-Plate v1.0 Quick Start Guide

Atomic and nuclear physics

USER MANUAL REFLEX SIGHT. Ultra Shot Z Series. English / Francais / Español / Deutsch

Zetasizer Nano-ZS User Instructions

RADIATION-METER TM-91/TM-92

Dual Red or Green Electronic Dot Sight Instruction Manual

Chapter 3 : ULSI Manufacturing Technology - (c) Photolithography

Experiment C-10 Titration of a Strong Acid and a Strong Base

Atomic and nuclear physics

Quick Start Guide. The ieq45 GoTo German Equatorial Mount # 8000C

Operation Manual. SPECTRO-NANO4 Nucleic Acid Analyzer PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

Fiducial Marks for EUV mask blanks. Jan-Peter Urbach, James Folta, Cindy Larson, P.A. Kearney, and Thomas White

Motion on a linear air track

Acid-Base Titration. Evaluation copy

High Optical Density Photomasks For Large Exposure Applications

Software BioScout-Calibrator June 2013

Sherlock Tutorial Plated Through Hole (PTH) Fatigue Analysis

BioMechanics and BioMaterials Lab (BME 541) Experiment #5 Mechanical Prosperities of Biomaterials Tensile Test

Operating Manual 1.1-4x24 Zenith x24 Zenith

Standardizing a Solution of Sodium Hydroxide. Evaluation copy

NSR-2205i14E (6" Reticle Type)

ACID-BASE TITRATION (MICROSCALE)

Photolithography Overview 9/29/03 Brainerd/photoclass/ECE580/Overvie w/overview

University of Colorado Denver Anschutz Medical Campus Online Chemical Inventory System User s Manual

DAY LABORATORY EXERCISE: SPECTROSCOPY

10 - Celestron Telescope II: Operation

Experiment P-9 An Inclined Plane

ISIS/Draw "Quick Start"

Account Setup. STEP 1: Create Enhanced View Account

Technical Procedure for Glass Refractive Index Measurement System 3 (GRIM 3)

ANALYSIS Safety Information for the University of California, Berkeley JOB WASTE RADIOACTIVE SAMPLING LIQUID EALTH & SAFETY R TASK HAZARDS CONTROLS

PoleMaster User Manual (Northern Hemisphere)

IC Fabrication Technology

RADIATION SAFETY GUIDELINES FOR NON-USERS

MASSACHUSETTS INSTITUTE OF TECHNOLOGY Physics Department. Experiment 03: Work and Energy

Instruction Manual. Made in Japan

RADIATION PROCEDURES MANUAL Procedure Cover Sheet

Rain Watch TM Set up Manual. IC System with Rain Bird IC CONNECT

Avery Dennison LW Series Retroreflective Window Sticker Film Issued: July 2013

Introduction to Hartree-Fock calculations in Spartan

FOCUS 30/FOCUS 35 Field Calibration with Survey Pro Field Software

5-25x56 PMII PSR With Double Turn

Inverted Pendulum System

Background The power radiated by a black body of temperature T, is given by the Stefan-Boltzmann Law

University of Minnesota Nano Center Standard Operating Procedure

mylab: Chemical Safety Module Last Updated: January 19, 2018

UNIVERSITY OF CALIFORNIA College of Engineering Department of Electrical Engineering and Computer Sciences. Professor Ali Javey. Fall 2009.

A clock designed in close consultation with people living with Dementia.

Experiment P-5 Motion of a Cart on an Inclined Plane

LEAPERS, INC. RED/GREEN DOTS

USER MANUAL REFLEX SIGHT. Ultra Shot Plus

INSTALLATION INSTRUCTIONS ATV Plow Blade Part Number: (50 ), (54 ), or (60 ) Application: All Terrain Vehicles

Section 5. TADS Data Reporting Instruction Manual DRAFT Section 5 and Associated Appendices With Proposed Event Type Numbers

Effects of Chrome Pattern Characteristics on Image Placement due to the Thermomechanical Distortion of Optical Reticles During Exposure

Chromeless Phase Lithography (CPL)

FIELD GUIDE FOR HORUS SCOPES

Devyser Index Plate A. Instructions for Use

Carrier Transport by Diffusion

RS-C Flexible Reticle Stocker

RS 1700/1900/2300/2900 High Density Reticle Stockers

This page intentionally left blank.

Creating Empirical Calibrations

Test Procedure for ItalSens IS-1 Graphite Sensors

Must Read Before Installation TadPoleTM Safety and Warnings

Red and Green Dot Sight FF26002 USER MANUAL

Photomasks. Photolithography Evolution 9/11/2004 ECE580- MPE/MASKS/PHOTOMASKS.PPT

Thin Wafer Handling Challenges and Emerging Solutions

Activity P20: Conservation of Mechanical Energy (Force Sensor, Photogate)

Appendix 2: Disassembling and Assembling the Telescopes and the Celestron Equatorial Mounts

Lab 1a Wind Tunnel Testing Principles & Drag Coefficients of Golf balls

MN-ISO-2000FN-E. ISO-2000FN COATING THICKNESS GAGE OPERATION MANUAL

Sample Alignment Part

E152 Standard Revision: EUV-pod Reticle Carrier

WARNING. INJURY HAZARD Failure to observe these instructions could lead to severe injury or death.

ULTRA SHOT PLUS - DARK EARTH REFLEX SIGHT SM26008DE

Acid-Base Titration. Sample

Magnetic Fields. Experiment 1. Magnetic Field of a Straight Current-Carrying Conductor

Service Information Letter SIL # 017

22X Builder s Level Model No Instruction Manual

Shown below is a sample titration curve for a diprotic acid. Note the two equivalence points.

TECHNICAL MANUAL 820 LX / 910 LX / 1300 LX

TORO SENTINEL APPLICATION NOTE AN01: ET-BASED PROGRAMMING

INSTALLATION INSTRUCTIONS ATV SNOW PLOW Mounting Kit: PN Application: HONDA 300

X: The Hall Effect in Metals

Please click the link below to view the YouTube video offering guidance to purchasers:

Description of the ED library Basic Atoms

SAFETY GROUP 430 SAFETY WALK-THROUGH CHECKLIST

HMS-5000 Manual. Product Name: HMS-5000 Hall Effect Measurement System with variable temperature from 80K to 350K. - Manual version: ver 5.

Transcription:

Approved by: Process Engineer / / / / Equipment Engineer 1 SCOPE The purpose of this document is to detail the use of the ASML PAS 5500 Stepper. All users are expected to have read and understood this document. It is not a substitute for in-person training on the system and is not sufficient to qualify a user on the system. Failure to follow guidelines in this document may result in loss of privileges. 2 REFERENCE DOCUMENTS Batch Control PAS 5500 Training Module Reticle Design Manual PAS 5500 User Guide PAS 5500 Job Definition PAS Global Alignment Strategies PAS 5500 Steppers up to and including /300 Stepper Introduction 3 DEFINITIONS n/a 4 TOOLS AND MATERIALS 4.1 General Description - The ASML PAS 5500/200 is a 5x reduction, i-line stepper set up for exposure of 6 inch wafers using 6 inch reticles. The system has 350nm resolution with a 0.48-0.60 variable numerical aperture. The maximum field size on the wafer is 22x22mm. Overlay capability is better than 50nm. All lithography levels for a particular design are included in a single stepper job. RIT SMFL Page 1 of 11

* * Reticle Pre-Alignment Marks RIT RIT Reticle Barcode Reticle Alignment Marks 4.2 Reticle Bar Code The reticle barcode is read as the reticle is removed from the reticle carrier. Reticle bar code information is specified in the stepper job. 4.3 Reticle Pre-Alignment Marks Two Pre-alignment Marks are located 135.5mm apart near the corners of the reticle. They are used to pre-align the reticle to the reticle table. 4.4 Reticle Alignment Marks - Two Reticle Alignment Marks, M1 and M2, are located 139mm apart near the left and right edges of the reticle. After the reticle is pre-aligned on the reticle table, the Reticle Alignment Marks are aligned to the permanent fiducial marks F1 and F2, located on the fiducial plate on the wafer table. 4.5 Wafer Zero Level The ASML Stepper utilizes zero level marks that are patterned and etched into the wafer before any other steps. An etch depth of 1200A +/- 10% allows the stepper to recognize the marks. It is possible to pattern the zero level at the same time as the first level, but overlay accuracy will be reduced since the first level is not aligned to the zero level. This is because the zero level is defined by a separate reticle. 4.6 Wafer Global Alignment - The wafer alignment marks W1, W2, etc, are exposed on the zero layer and etched into the wafer. Two of these marks are sufficient but up to 25 may be used on a single wafer. If more than two marks are used, the stepper will find a best alignment and expose all die using the same settings. The stepper uses through the lens alignment of the wafer and the reticle. RIT SMFL Page 2 of 11

4.7 Wafer Field by Field Alignment This method uses marks that are part of the CAD data for each mask layer; they are not exposed individually. These marks may be placed in the scribe lanes. Field by field alignment takes longer than global alignment because each die is aligned. 4.8 Standard Jobs Several standard jobs are available for use with the Standard Reticle Templates. This allows a user to process wafers without having to develop a new stepper job. These jobs should not be changed but may be copied and saved as new jobs. 5 SAFETY PRECAUTIONS 5.1 Hazards to the Operator 5.1.1 The ASML uses ultraviolet light as well as lasers, and should only be operated with all of the covers closed. Safety glasses should be worn at all times. 5.1.2 The ASML stepper had mechanical hazards. Do not operate with open covers and do not open any covers during operation. 5.2 Hazards to the Tool 5.2.1 Never open or service the wafer stage since serious damage to the tool can occur. 5.2.2 Never manually remove stuck wafers from the system. Please contact the tool technician. 5.2.3 Reticle changing should only be done by a certified user. Use care not to touch the surface of the reticle. If alignment marks become obscured, the stepper will not be able to find them. 5.2.4 Do not remove the Combi reticle from the SMIF pod. It is fragile and expensive to replace. 5.2.5 Wafers must have clean backs. This will keep the stage clean and prevent errors. 5.2.6 Do not remove a carrier that is not fully raised. RIT SMFL Page 3 of 11

Reticle Changer Unload Load 6 INSTRUCTIONS 6.1 Starting the System 6.1.1 Swipe the tool in on the Card Swipe System. 6.1.2 Verify that the computer is on. 6.1.3 Make sure that the computer is on the Main Menu, if not select 0 Exit. Do not exit from the Main Menu. RIT SMFL Page 4 of 11

6.2 Loading the Reticles 6.2.1 To remove the reticle box from the machine, under select Mat Hdl from the top of the screen and then 3 Exchange Reticle Box. Click the Unlock button in the middle of the screen to unlock the reticle box. 6.2.2 Remove the box by lifting straight up 2 cm, tilting the front up and moving it away from the stepper at a 45 degree angle. Always support the reticle box on the bottom to prevent reticles from falling out. 6.2.3 Carefully open the reticle box. The clear top is released from the base by sliding the 4 clamps underneath the base. Load the reticles chrome side down with the prealignment stars facing out. Never touch the surface of a reticle. Close the reticle box and make sure it is secured before lifting. Do not remove the Combi Reticle from the top slot. 6.2.4 To load the reticle box, lower it straight down without tilting it. The open side of the internal cassette should be towards the stepper. 6.2.5 Select the Read 1 button to read the barcodes and display the reticle IDs. RIT SMFL Page 5 of 11

6.2.6 If your reticles do not have bar codes, use the Specify button to enter reticle IDs and then the Apply button to confirm. This will have to be done each time the reticles are loaded into the machine. 6.2.7 When finished, the reticle box should be stored on the stepper. 6.2.8 Press Cancel and Exit back to the Main Menu. 6.3 Loading Wafers 6.3.1 Lift the cover to the loader and place the cassette of wafers on the stage. Make sure that the cassette is properly seated. 6.3.2 Place an empty cassette on the receiver. All 4 stations should have a cassette. 6.4 Defining a Batch and Running a Stepper Job 6.4.1 From the Main Menu, select 2- Batch Control and 1 Define Batch. 6.4.2 The Batch ID is the name that you use to identify your wafers. 6.4.3 The Job Name is the name of the stepper job that you want to use. Click the Select button, scroll down, select the job and Accept at the top of the screen. Writing a stepper job is detailed in a separate document. 6.4.4 Click on the line to the right of Layer ID. Select the Layer Number that you want to expose when the box comes up. Layer number zero is used for exposing the alignment marks onto the wafer. See attachments for more information on the zero level. 6.4.5 The Control Mode may be set to W or C. A setting of C will expose all of the wafers in the cassette. A setting of W will only expose the number of wafers that you specify. 6.4.6 The Batch Size is the number of wafers or cassettes that you want to expose. 6.4.7 Under Batch Type select P for production. F will allow you to do a focus meander, E will allow you to do an energy meander and M will allow you to do a matrix. RIT SMFL Page 6 of 11

6.4.8 Under Process Data you may adjust exposure energy, focus and tilt settings. The minimum energy is 40mJ/cm 2. Under Illumination Mode select either conventional or annular. Numerical aperture and sigma may be specified. After changing any of these values you must select the Apply button for the changes to take effect. 6.4.9 The Clear button at the bottom of the screen will clear all of the entries and allow you to start over. 6.4.10 The Run button will start the batch. Wafers will automatically load, align, expose and unload. 6.5 Unloading Wafers 6.5.1 Lift the cover on the output cassette and remove the wafers. Do not remove a carrier that is not fully raised. 6.5.2 Place the empty cassette back on the tool. All 4 stations should have a cassette. 6.6 Unloading Reticles 6.6.1 To remove the reticle box from the machine, under Main Menu, select Mat Hdl from the top of the screen and then 3 Exchange Reticle Box. Click the Unlock button in the middle of the screen to unlock the reticle box. 6.6.2 Remove the box by lifting straight up 2 cm, tilting the front up and moving it away from the stepper at a 45 degree angle. Always support the reticle box on the bottom to prevent reticles from falling out. 6.6.3 Carefully open the reticle box. Unload the reticles. Never touch the surface of a reticle. Close the reticle box and make sure it is secured before lifting. 6.6.4 Replace the reticle box on the stepper by lowering it straight down without tilting it. The open side of the internal cassette should be towards the stepper. The reticle box should be stored on the stepper when finished. 6.6.5 Exit back to the Main Menu. RIT SMFL Page 7 of 11

6.7 Resetting the System 6.7.1 To remove all wafers from the machine, select Batch Control from the Main Menu, select Mat Hdl from the top of the screen and then 2 Remove Wafers from Machine. Never manually remove stuck wafers from the machine. 6.8 Errors during Run 6.8.1 If any errors occur contact the equipment engineer. 6.9 Introducing a Layer Shift 6.9.1 Select Process Data in your stepper job to enter a layer shift in microns. See Section 6.8 of the ASML PASS 5500 Job Creation Manual. 7 APPROPRIATE USES OF THE TOOL 7.1 No backside coated wafers, only wafers with clean backs may be processed in this tool. 7.2 No polyimide or SU8 may be processed in this tool. 8 ATTACHMENTS 8.1 Dose to Clear Test (Exposure Matrix) 8.1.1 This test is done with or without a mask and the full field is exposed. 8.1.2 From the Main Menu select 6-Test Manager. 8.1.3 Select 1-Run Test. 8.1.4 Move to the top of the directory by clicking Up. 8.1.5 Select Illumination System. 8.1.6 Select Performance Tests. 8.1.7 Select Resist Uniformity. 8.1.8 Select Accept at the top of the screen. RIT SMFL Page 8 of 11

8.1.9 Input the Nominal Energy, the Energy Increment and the Window Size. Be sure to hit return after each entry. 8.1.10 Select Accept. 8.1.11 One wafer will be exposed with the nominal exposure in the center of the wafer. The remaining exposures will be divided up above and below this. When the wafer is finished, a report will come up and show the exposure pattern. 8.1.12 When finished select Exit twice to return to the Main Menu. 8.1.13 A dose to clear test can also be done in the screen used to define a batch. 8.2 FEM (Focus/ Exposure Matrix) 8.2.1 From the Main Menu select 6-Test Manage. 8.2.2 Select 1-Run Test. 8.2.3 Move to the top of the directory by clicking Up. 8.2.4 Select Projection Systems. 8.2.5 Select FEM Developer/Customer. 8.2.6 Select Accept at the top of the screen. 8.2.7 Input desired values for matrix size, energy, increment, focus and the number of die to be exposed. Each die is a complete focus/ exposure matrix. 8.2.8 Select Accept. 8.2.9 When finished select Exit twice to return to the Main Menu. 8.2.10 A Focus/Exposure test can also be done in the screen used to define a batch. 8.3 Running RIT Daily 8.3.1 From the Main Menu select 6-Test Manager. 8.3.2 At the top of the dialog screen select CMD HDL. 8.3.3 From this screen select 8-Contamination and Temperature Control. RIT SMFL Page 9 of 11

8.3.4 Select 2-Sensor Module Commands. 8.3.5 Select 4-Monitor All Sensor Values. 8.3.6 Ensure that the Lens Temperature is 22.01C (+/- 0.02C). 8.3.7 Select Cancel at the top of the screen. 8.3.8 Select Exit 3 times to return to the Test Manager menu. 8.3.9 Select 3 - Run Test Que. 8.3.10 Select Select. 8.3.11 Scroll down until you see daily RIT. Characters are case sensitive. 8.3.12 Select Accept at the top of the screen. 8.3.13 Select Accept again and the test will run. 8.3.14 Select Exit twice to return to the Main Menu. 8.4 Procedure for Creating a Zero Level 8.4.1 Load the Combi Reticle. 8.4.2 Select your stepper job. 8.4.3 Select Layer ID. 8.4.4 Select Zero Layer to expose your marks. 8.4.5 Develop and bake the resist. 8.4.6 Plasma etch the zero level marks with the Drytek Quad using the ZEROETCH recipe. The marks should be 1200Å +/- 10%. 8.4.7 Strip the photoresist. RIT SMFL Page 10 of 11

REVISION RECORD Summary of Changes Originator Rev/Date Original Issue Sean O Brien A-07/20/2010 Clarified some of the instructions Sean O Brien B-12/21/2010 RIT SMFL Page 11 of 11