ASSESSMENT OF DAMS AND DIKES BEHAVIOR WITH A FIBRE OPTICS BASED MONITORING SOLUTION

Similar documents
Thermal Monitoring of Embankment Dams by Fiber Optics

Thermal monitoring of dams and levees

Data Verification, Analytics and Visualization

Smart levees a new future for flood management?

CCR Rule Annual Inspection Report (cont.) 2

PROBLEMS AND SOLUTIONS THAT MAY EMERGE IN THE FOUNDATION AND BODY OF A HOMOGENEOUS FILL DAM ON A WEAK CLAYEY-SILTY-SANDY FORMATION ÇIKRIKÇI DAM

[1] Performance of the sediment trap depends on the type of outlet structure and the settling pond surface area.

Geosynthetics Applications and Performance Reviews Select Case Histories

Displacement and Settlement Monitoring in Large Geotechnical Structures with a Novel Approach to Distributed Brillouin Sensing

U-Shaped Sediment Traps

Contribution of new technologies for the monitoring of hydraulic plants: the EDF experience

Coarse Sediment Traps

Investigation of shallow leakage zones in a small embankment dam using repeated resistivity measurements

design, construction, operation, and maintenance of the BAP is consistent with recognized and generally accepted good engineering standards.

Type 1 System Sheet Flow Sandy Soils Type 2 System Concentrated Flow Clayey Soils Type 3 System [1] Supplementary Trap Dispersive Soils

Rock & Aggregate Drop Inlet Protection

Effect of River Levee with Geosynthetic- Reinforced Soil against Overflow Erosion and Infiltration

Practical aspects of dam break analysis

SETTLEMENTS OF AN EMBANKMENT FOUNDED ON A SOFT SOIL

Stone Outlet Sediment Trap

WP2.1 BREACH FORMATION LARGE SCALE EMBANKMENT FAILURE

Modeling Great Britain s Flood Defenses. Flood Defense in Great Britain. By Dr. Yizhong Qu

Countermeasure Calculations and Design

This report was prepared by Klohn Crippen Consultants Ltd. for Alberta Transportation Central Region under Contract No. CE053/2000.

COMPARISION OF HYDRAULIC GRADIENT AND UPLIFT PRESSURE IN THREE TYPES OF DAMS: HOMOGENEOUS, HETEROGENEOUS EARTHFILL DAMS AND CONCRETE GRAVITY DAM

June 9, R. D. Cook, P.Eng. Soils Engineer Special Services Western Region PUBLIC WORKS CANADA WESTERN REGION REPORT ON

Seismic Analysis of Siri Dam Using Pseudo-Static Approach

Materials. Use materials meeting the following.

Practical methodology for inclusion of uplift and pore pressures in analysis of concrete dams

Instructor : Dr. Jehad Hamad. Chapter (7)

1 PROJECT BACKGROUND. August 14, Alberta Transportation Central Region #401, Street Red Deer, Alberta T4N 6K8

GEOTECHNICAL ENGINEERING ECG 503 LECTURE NOTE ANALYSIS AND DESIGN OF RETAINING STRUCTURES

Luca Palmieri Thom Bogaard Miguel Gonzalez-Herraez Alessandro Pasuto. Water JPI WaterWorks2014 Cofunded Call 18 May 2016, Rome

ICOLD TCDS - Technical Committe on Dam Surveillance

Agenda. INDOT Office of Environmental Services. Describe Results of FHWA QAR. Landscape and Waterway Permitting Unit. Interviews Site Inspections

(Refer Slide Time: 01:15)

Design of Safety Monitoring and Early Warning System for Buried Pipeline Crossing Fault

PREDICTION OF FROST HEAVE INDUCED DEFORMATION OF DYKE KA-7 IN NORTHERN QUEBEC

Instream Sediment Control Systems

B805 TEMPORARY EROSION AND SEDIMENT CONTROL MEASURES - OPSS 805

Dynamic Response of EPS Blocks /soil Sandwiched Wall/embankment

RESERVOIR DRAWDOWN RATES/RESERVOIR DRAWDOWN TEST Iron Gate, Copco (I & II), and JC Boyle Dams


THE EFFECT OF RESERVOIR WATER LEVEL FLUCTUATION TO THE SEEPAGE ON EARTH DAM

Effect of tire type on strains occurring in asphalt concrete layers

RESEARCH ON CAUSE OF DAM FAILURE FROM VIEWPOINT OF HYDRAULIC FRACTURING CASE STUDY OF A DAM FAILURE IN VIETNAM

**Temporary Erosion Control**

Analysis of soil failure modes using flume tests

PRESSURE AND SCOURING AROUND A SPUR DIKE DURING THE SURGE PASS


Sediment Trap. A temporary runoff containment area, which promotes sedimentation prior to discharge of the runoff through a stabilized spillway.

Rock Sizing for Small Dam Spillways

Introduction to Geotechnical Engineering. ground

GEOSYNTHETICS ENGINEERING: IN THEORY AND PRACTICE

EARTHQUAKE SAFETY OF AN ARCH-GRAVITY DAM WITH A HORIZONTAL CRACK IN THE UPPER PORTION OF THE DAM

Internal C Unit Dilatanc y

J. Paul Guyer, P.E., R.A.

Numerical analysis of effect of mitigation measures on seismic performance of a liquefiable tailings dam foundation

VERIFICATION OF MATERIAL PARAMETERS OF EARTHEN DAMS AT DIAMOND VALLEY LAKE USING GEODETIC MEASUREMENTS

Analysis of soil failure modes using flume tests

Landslide Granice in Zagreb (Croatia)

Sediment Weirs (Instream)

Temporal variability of partially-contaminated sediments in a strongly regulated reservoir of the upper Rhine River

Module 2 Lecture 9 Permeability and Seepage -5 Topics

LAND SLIDE STABILIZATION FOR A WORKING PLATFORM WHICH OCCURRED DURING EXCAVATION IN CLUJ-NAPOCA

International Journal of Scientific & Engineering Research, Volume 8, Issue 2, February ISSN

GEOTECHNICAL ENGINEERING II. Subject Code : 06CV64 Internal Assessment Marks : 25 PART A UNIT 1

The results of KCB s site inspection observations and our recommendations for further work are presented herein.

Culvert and Pipe Phasing

Converse Consultants Geotechnical Engineering, Environmental & Groundwater Science, Inspection & Testing Services

Rock Sizing for Waterway & Gully Chutes

Climate effects on landslides

EXPERIMENT OF CHANNELIZATION DUE TO SEEPAGE EROSION

Parametric Inversion of Brillouin Spectra to Enhance the Accuracy of Distributed Strain Measurement

Pullout Tests of Geogrids Embedded in Non-cohesive Soil

Analysis of Inclined Strip Anchors in Sand Based on the Block Set Mechanism

Determination of Excess Pore Pressure in Earth Dam after Earthquake

3/8/17. #20 - Landslides: Mitigation and Case Histories. Questions for Thought. Questions for Thought

PERENNIAL PROBLEM OF EARTHEN BUND OF WELLINGDON RESERVOIR. ANALYSIS OF CAUSES AND REMEDIAL MEASURES A CASE STUDY.

STRUCTURAL STABILITY ASSESSMENT

PRINCIPLES OF GEOTECHNICAL ENGINEERING

Field measurements of the settlements induced by preloading and vertical drains on a clayey deposit

Landslide FE Stability Analysis

SHEET PILE WALLS. Mehdi Mokhberi Islamic Azad University

A Fundamental Approach for an Investigation of Behavior Characteristics of the Vegetation Structures Using Seeded Sandbags

January 17, 2008 File:

Geotechnical Modeling Issues

SI Planning & Laboratory Testing for Hill-Site Development

Chapter 7 Permeability and Seepage

Reinforced Soil Structures Reinforced Soil Walls. Prof K. Rajagopal Department of Civil Engineering IIT Madras, Chennai

STABILITY ANALYSIS OF EARTH DAM SLOPES SUBJECTED TO EARTHQUAKE USING ERT RESULTS INTERPRETATION

(Refer Slide Time: 02:18)

Deformation And Stability Analysis Of A Cut Slope

APPENDIX B WORKSHEETS & EXHIBITS

ICOLD Bulletin 164 on internal erosion of dams, dikes and levees and their foundations

Converse Consultants Geotechnical Engineering, Environmental & Groundwater Science, Inspection & Testing Services

Chutes Part 5: Rock linings

Construction Exits Rock pads

GEOSYNTHETICS ENGINEERING: IN THEORY AND PRACTICE

ch-01.qxd 8/4/04 2:33 PM Page 1 Part 1 Basic Principles of Open Channel Flows

Transcription:

ASSESSMENT OF DAMS AND DIKES BEHAVIOR WITH A FIBRE OPTICS BASED MONITORING SOLUTION O. Artières TenCate Geosynthetics, Bezons, France Y.L. Beck, A.A. Khan, P. Cunat EDG-DTG, Grenoble, France J.J. Fry, J.R. Courivaud EDG-CIH, Chambery, France C. Guidoux, P. Pinettes geophyconsult, Chambery, France ABSTRACT: The optical fiber based monitoring solution can detect and localize the early signs of malfunctioning, such as leaks or instability, and enhance the long term performance of the dams. It is based on the combination of a technical textile, embedded fiber optic sensors, a related instrumentation, an appropriate design and installation of the system, and a deep data analysis. The system is able to monitor several tens of kilometers with distributed and continuous measurements, which increases the accuracy and the speed of response, crucial parameters to prevent collapse. Detection performance as low as 0.1 l/min/m for leakage and as low as 0.02% soil strain has been validated on experimental works scale 1:1. This solution is used on several dikes and levees. 1 INTRODUCTION Monitoring the behavior of new and old dams is a key issue in the field of dam maintenance. Thanks to the early detection of precursors of malfunctioning such as leakage, erosion, relative deformation or settlement, it is possible to react very fast when necessary or to check periodically the slow dam ageing process and to plan the maintenance works in due time. The TenCate GeoDetect monitoring technology detects both internal erosion and instability at an early stage. It is based on the combination of a technical textile with embedded fiber optic cables that are connected to appropriate optical instrumentations to measure soil temperatures and strains. The current performance of the GeoDetect global solution has been validated in France and in The Netherlands: the strain resolution can be as little as 0.02% and the temperature resolution as little as 0.1 C, with spatial resolutions of 1 m up to 20 km in distance. It has been used in two different test series in the recent Dutch experimental IJkdijk project. In the first test series, based on the simulation of a 100 m long macro-instability dyke, the GeoDetect solution has been the only system among ten others able to detect and localize the start of the dike slide more than 2 days before its collapse during the 4 full days of experimentation time. In the second test series, based on the simulation of piping, it has been the only system able to generate real-time alarms, 2 days prior to failure. The GeoDetect monitoring and early warning solution is now being used in several real sites. After introducing the principle of this monitoring solution and describing its real performance based on the experimental dikes, the installation and the data analysis on several dykes will be described. 2 THE FIBER OPTICS BASED MONITORING SOLUTION 2.1 The textile fiber optics composite sensor The fiber optics have been widely used for many years in civil engineering applications and specially hydraulic works such as concrete and earthdams, levees and dikes. By embedding optical cables into a geotextile fabric (Fig. 1), GeoDetect is the first system designed specifically for geotechnical and hydraulics applications. The geotextile fabric, e.g. a textile installed in the soil, enhances its mechanical and hydraulic properties by in-plane drainage capability, anchoring interface with the soil, soil reinforcement, separation and filtration. For example the drainage properties of the geotextile combined with the temperature measurement with the optical fibers improves the speed of leakage detection by collecting the water-flow and draining it faster to the optical fiber. Moreover, the filtration properties of the geotextile increase the stability of the soil to prevent the internal erosion process.

Also the high soil-textile interface friction properties and the strong link between the optical cable and the geotextile help to transfer and detect very small soil strains. The GeoDetect sensor is designed to detect the first steps of internal erosion processes and hydraulic works instability. The detection of the leaks, which is the early stage of the internal erosion process, is assessed through the measurement of temperature changes using the passive method or the active heat pulse method (Radzicki et al., 2009). First stages of dike settlement or sliding are detected by strain measurement. Measuring at the same time and at the same location both temperature for leaks detection and soil strain for soil movement detection increases the probability of obtaining the right precursors of a malfunctioning. This development was handled through a partnership of companies and public research institutes including several authors of this paper within the European Eureka R&D project SafeDike. length, which increases the accuracy and the speed of response, both crucial parameters to prevent collapse. It can provide a leak and deformation location with a spatial resolution of 1 meter, or even 0.5 m in some cases. The system is able to monitor several tens of kilometres. Figure 2. The Raman instrumentation for temperature measure ment (on top) and the Brillouin instrumentation for strain measurement (at the bottom) Figure 1. The TenCate GeoDetect S-BR textile composite sensor embedding 4 optical cable, 2 for temperature and 2 for strain measurement 2.2 The monitoring and early warning system The GeoDetect monitoring system combines the benefits of geotextile materials with the latest optical sensing and measurement technologies. It uses either the stimulated Brillouin or Raman scattering technology in single mode or multi-mode optical fibers to measure both strain and temperature, or local Fiber Bragg Grating (FBG) sensors placed on single mode fibers to measure strain very precisely both under static or dynamic conditions. Combined with the appropriate software and instrumentation (Fig. 2), it provides an innovative solution for the multi-functional requirements of geotechnical and hydraulic applications in addition to data capture. Different monitoring strategies may be designed, for example temporary monitoring, or continuous monitoring to be used as an early warning system. In comparison to existing detection systems, the GeoDetect solution is a distributed and continuous measurement along the whole hydraulic works Figure 3. Installation of one GeoDetect S-BR sensor strip in the Ijkdijk macro-stability dike.

2.3 The full monitoring solution Beside the hardware components of the system, important parts of this global solution are the design and implementation of the system within the work and the interpretation of the raw thermal and strain data. The detection of very small water pipes (or wormholes) for example has been improved recently. The physico-statistical and signal processing methods developed by EDF and used by geophyconsult allow the proposed system to be able to send «early warnings» which is compatible with long-term monitoring. The GeoDetect solution has been validated on several 1:1 scale experimental works and real dikes in-use, as presented in the next sections. 3 PERFORMANCE EVALUATION OF DAM STABILITY MONITORING state-of-the-art multi-sensor networks and IT-tools can supplement standard visual inspections and existing water management systems. About ten different techniques were used. The second objective was to obtain knowledge about failure mechanisms and to carry out model validation (IJkdijk, 2008). The fiber optics GeoDetect system was installed lengthwise to the dike at four different levels : top on the crest, at the middle, at the toe of the downstream slope, and 2 m meters away from the downstream toe (Fig. 5). The four strips, 100 m long each, were all connected together in a loop to the instrumentation in a cabinet at about 50 m from the experimental dike. Both optical cables for strain measurement using the Stimulated Brillouin Scattering and for temperature compensation measurement using the Raman Scattering technologies were embedded onto the textile strips. First stages of dike settlement or sliding are detected by strain measurement. An experimental dyke 100 m long and 6 m high was built within the Dutch IJkDijk (Smart Calibration Dike) project to test the ability of sensoring systems to detect dam failure due to internal instability (Fig. 4). The IJkdijk-site is located in the North-East of the Netherlands, close to the German border. Experiments were carried out with the following objectives. The first goal was to test whether the Figure 6. Relative strain measured on Sept. 25th 08:00 a.m. with the TenCate GeoDetect system, 2.5 days before dike collapse : 0.03 % on the top strip, 0.005% on the middle strip (geophyconsult data processing). Figure 4. Aerial view of the IJkdijk experimental dike during the macro-stability experiment, the upstream basin on the left filled with water, loading containers on top, and the trench diged out 2 m from the dike toe. Figure 5. Placement of the 4 GeoDetect sensor strips along the IJkdijk macro-stability dike, at the crest (TOP), at the middle of the slope (MIDDLE), at the dike downstream toe (TOE), and 2 m from the downstream dike toe (FIELD). Figure 7. Relative strain measured on Sept. 26th 04:00 p.m. with the TenCate GeoDetect system, 1 day before dike collapse : the tension zones on each strips draw the boarder of the slope slipping area (geophyconsult data processing).

In September 2008, during the test, the global factor of safety of the dyke was decreased step by step by digging a trench at the downstream toe and by increasing the internal water pressure till failure by slippage of an area of the downstream face. The failure took place on the third day of the test, during bright sunny conditions. The visible part of the failure took only 40 to 50 seconds, so it was a fast process. The monitoring system worked perfectly as it was able to detect and localize the early signs of soil movements 2.5 days before the dike collapses, i.e. only one day after the start of the experimentation. Very small soil strains of 0.03 % on the top strip and less than 0.01% on the middle strip were measured, see round red circles in Figure 6. The boarders of the instable zone inside the dyke body were clearly localized more than one day before the failure occurred, when nothing was visible from outside (Fig. 7). They exactly correspond to the area of the slipping slope. Soil strain detection and measurement with the GeoDetect monitoring solution had already been proven in previous earthworks, such as walls or embankments over instable soils, with another fiber optics technology, the Fiber Bragg Gratings (FBG) (Nancey et al., 2006; Briançon et al, 2006). This IJkdijk macrostability experimentation, confirmed the capability of this system to detect and localize small soil strains in hydraulics works on longer distances by using the Brillouin distributed scattering technology. three textile sensor strips embedding fiber optics for both temperature and strain measurement were buried 10 cm into the sandy subsoil lengthwise the dike at three different locations ITA0, ITA1 and ITA2 from the downstream toe of the dike as indicated in figure 9. The temperature optical line was connected to Raman Scattering instrumentation, the strain optical line was connected to Stimulated Brillouin Scattering instrumentation. Even though the right detection place would be the interface between the sand subsoil and the clayey dike, as it is where the higher hydraulic gradient occurs, the strips were only allowed to be buried into the sand so as not to disturb the erosion process to be studied during this experimentation. Figure 8. Downstream side of the IJkdijk experimental dyke a few minutes before collapse with clear view of the piping chanel and sand erosion at the toe The coloured labels at the toe indicate the observed flows, red with sand transport, blue only water (from Stiching IJkdijk). 4 PERFORMANCE EVALUATION OF DAM INTERNAL EROSION DETECTION Another series of 4 experimentations was carried out in 2009 during the second IJkdijk-Piping experimental project for the detection of the early signs of internal erosion at the interface between a clayey dike and sandy erosive subsoil. Full scale levees were built and brought to failure with two explicit goals: to increase the knowledge on levee behavior and to develop and test new sensor technologies for early warning systems under field conditions. Four experiments have been carried out, aiming at failure caused by under-seepage erosion (piping). The clay levee with a height of 3.5m and slopes of 1:2 was built on top of the sand, 15 m long and 12 m wide. To create erosive channels, water head was increased step by step up to 3 m maximum, to obtain sufficient hydraulic forces to generate an internal piping process. The downstream toe of the dike was inspected visually and continuously to detect water outlets, with or without soil transport. The test stops when the dike collapses (Fig. 8). As for the macro-stability project, several detection methods were tested. Among them, the GeoDetect system was installed in the test number 4 : Figure 9. Location of the 6 GeoDetect strips into the sand below the IJkdijk experimental dike. Figure 10. Installation of the GeoDetect sensor strips embedding both strain and temperature fiber optics 10 cm into the sand layer before constrution of the experimental dike.

Three other strips with only temperature optical fibers were installed further up on the upstream toe of the dike at the positions ITA3, ITA4 and ITA5. Figure 11 shows the maps of the raw temperatures (left column) and of the relative strains (right column) measured by the GeoDetect system. The temperature profile is disturbed due to the penetration of a colder water flow inside the dike body at distance of about 12 m from the left upstream corner and an inflection of the channel inside the dike body predicting a channel outlet in an area between 8 to 10 m from the left downstream corner. The strain profile on the left is also slightly modified at the same distances with an elongation of the sensors corresponding to about 500 µε or 0.05 % (dotted white lines). From the observation of these two parameters, this clearly indicates that the start of the piping channel from the upstream side to the downstream side of the dike took place before December 4th, 2009 at 6 p.m., i.e. more than 15 hours before the dike failure occurs. This is confirmed by the evolution of these parameters till December 5th, 2009 at 11 a.m (Fig. 12), 5 hours before the dikes collapses (Fig. 13). A post-failure analysis carried out by EDF on a another experimental dike (IJjkdijk Piping test n 2) based on signal processing models developed by EDF n 4 showing the extension of the piping chanel bellow the dike (geophyconsult data processing). that is about to be included in real-time data analysis modules has revealed the presence of precursors 5 days before collapse, i.e. only one day after the start of the experimentation (Beck et al., 2010). It has also been observed from the temperature measurements that the speed of the detection increases when the optical cables are located where the leaks are foreseen, here at the interface between the sand and the clayey dike, which would be the case for a non experimental work. This IJkdijk-piping experimentation clearly demonstrates the capabilities of the GeoDetect system to detect the early stage of a piping process, by analyzing together temperature measurement corresponding to very small leakage rates, less than 1 l/min./m as previously observed in other sites (Artières et al., 2007), and very small soil strain movements less than 0.1%. C 8 6 Temperature in C Dike width in m 12 6 Strain in µε (10-4 %) µε +1500 +1000 +500 4 0 Dike length in m 15 0 0 Dike length in m 15 0 - Figure 13. Collapse of the IJkdijk-Piping experimental dyke after the internal erosion process is completed (from Stiching IJkdijk). Figure 11. IJkdijk piping dike - Temperature (left) and strain (right) profiles measured on Dec. 4th 06:00 p.m. with the TenCate GeoDetect system, 22 hours before dike collapse. Hetorogeneities appear on the map (white dot line) (geophyconsult data processing). C 8 6 4 Temperature in C 0 Dike length in m 15 Dike width in m 12 6 0 Strain in µε 10-4 % 0 Dike length in m 15 +1500 +1000 +500 Figure 12. IJkdijk piping dike -Temperature (left) and strain (right) profiles measured on Dec. 5th 11:00 a.m., 5 hours before dike collapse from the raw data on the Ijdijk piping test µε 0 - Figure 14. Canal form the Marne to the Rhine river. The section with 4 GeoDetect strips.

5 MONITORING A WET CANAL DIKE This section describes the monitoring of a 100 m long section of dike along the canal from the Marne River to the Rhine River in France owned by the French waterways (VNF) with the GeoDetect solution. This old dike was chosen because leakage was expected in the area, but the localization of the leaks were difficult due to the vegetation on the downstream slope of the dike, and also due to the longitudinal slope of the dike toe collecting large amount of water. The dike is about 3 m high and built with rather homogeneous clayey soil. In this section, it was decided to remove from 20 cm to 40 cm thick of the organic top soil along the downstream slope, before installing four textile sensor strips at different level: top, middle, toe and 2 meters from the toe (Fig. 14). The strips are embedding fiber optic cables both for temperature and strain measurement (Fig. 1). The optical lines were connected as a loop to the Raman and Brillouin distributed scattering instrumentation. After installation of the sensors strips, a filtration geotextile was laid on the entire slope and covered with granular material and organic soil, 20 cm thick at the top and 1 m thick at the toe. The data acquisition took place for about 3 months during the summer 2009. Figure 15. Canal Marne to Rhine rivers. Maping of the temperature raw data (in C) on the four sensor strips from June 12th, 2009 (on top of the figure) till August 24 th, 2009 (bottom of the figure) (geophyconsult data processing). Figure 17. Canal Marne to Rhine rivers. Maping of the dissimilarities from the daily temperature data (in -) on the four sensor strips on April 25th, 2009 (geophyconsult data processing). Figure 16. Canal Marne to Rhine rivers. Maping of the dissimilarities from the daily temperature data (in -) on the four sensor strips from April 17th, 2009 (on top of the figure) till August 28 th, 2009 (bottom of the figure) (geophyconsult data processing). The mapping of the temperature data is shown on the figure 15. A temperature anomaly is visible at a 20 m distance on the 3 lowest strips, from the middle to the field, and at about 40 m on the field strip (red arrows). For a better data interpretation, a data analysis was carried out using the EDF signal processing model resulting to dissimilarities to daily temperature (Beck et al., 2010). This data treatment confirms one big temperature anomaly on the bottom and field strips at a distance of 30-40 m (Fig. 16 & 17), which was less obvious on the raw data mapping.

Also visible is the anomaly at 15 m (field) and 57 m (top). It can be observed on figure 16 that the signal at 40 m on the field and bottom sensors is not permanent: the cause could be the change of water level into the canal. The strain mappings are drawn on figure 18. As top sensor is only 20 to 30 cm deep below the surface, the strain data has been corrected with temperature data measured on the other line. The other strips are deeper into the soil and the temperature influence is negligible. The mappings show little movement of the dike which indicates that the observed leakages are not acting on the dike stability. The highest tensile zones, about 0.03%, appears at the top line at 40-45 m from June 27th, corresponding to a settlement that can be visually observed at the crest of the dike. Another one is seen at the bottom line at a 10 m distance whose magnitude increases with time. Lighter tensile areas are observed on middle line at 50-60 m. There is no direct correlation between these tensile zones and the leakage observed previously. The measured tensile strains may correspond to slight field movements. This analysis shows that there are local differential settlements inside the dike, but no general movement affecting the dike stability. 6 CONCLUSION Monitoring old and new dams has become a very important issue for their maintenance and the safety. Solutions based on the fiber optic technology demonstrated over the past 5 years have proven their performance in detecting the early signs of dam ageing. Among them, the GeoDetect monitoring system, with the embedment of several optical fibers for both temperature and strain measurement is very sensitive to detect small temperature changes as little as 0.1 C, small leaks from 0.1 l/min/m and light soil strain as little as 0.02 %. Combined with the proper design, installation and a deep raw data analysis from robust signal processing models it is shown to be a powerful early warning solution. It provides dam owners with unique information that drives risk reduction and optimizes the cost of their maintenance strategy. 7 REFERENCES Figure 18. Canal Marne to Rhine rivers. Maping of the strain raw data (in µε) on the Top, Middle and Bottom sensor strips from June 27th, 2009 (on top of the figure) till September 30th, 2009 (bottom of the figure). (geophyconsult data processing). Artières O., Bonelli S., Fabre J.-P., Guidoux C., Radzicki C., Royet P., Vedrenne C. 2007. Active and passive defenses against internal erosion. Proc.7th ICOLD European Club Dam Symposium. Freising (Munich), Germany, September 17-19, 2007. 10 p. Beck Y.-L., Khan A. A., Cunat P., Guidoux C., Artières O., Mars J., Fry J.-J. (2010). Thermal monitoring of embankment dams by fiber optics. Proc. 8th ICOLD European

Club Symposium on dam safety, Innsbruck, Austria; September 22-23, 2010. Briançon L., Nancey A., Robinet A. & Voet M. 2006. Set up of a warning system integrated inside a reinforced geotextile for the survey of railway. Proc. 8th Int. Conf. on Geosynthetics, Yokohama, Japan. Geosyntetics, J. Kuwano & J. Koseki (eds), Balkema, Rotterdam: 857-860 Ijkdijk, 2008. Ijkdijk macrostability-experiment. Stiching IJkdijk, available on www.ijkdijk.eu, 4 p. IJkdijk-Piping, 2009. Leaflet available on the website www.ijkdijk.eu. 4 P. Nancey A., Rossi D., Boons B. 2006. Survey of a bridge abutment reinforced by geosynthetics, with optic sensors integrated in geotextile. Proc. 8th Int. Conf. on Geosynthetics, Yokohama, Japan. J. Kuwano & J. Koseki (eds), Balkema, Rotterdam: 1071-1074 Radzicki K., Bonelli S., Beck Y.L. & Cunat P. (2009), Leakage and erosion processes identification by temperature measurements, in upstream part of earth hydraulic works using the impulse response function analysis method. European Working Group in Internal Erosion, St Petersburg, Russia.