It is possible to choose the temperature for each experiment by setting a temperature under the Temp pane (under the Standard panel).

Similar documents
NMR Spectroscopy: A Quantum Phenomena

High-Resolutio n NMR Techniques i n Organic Chemistry TIMOTHY D W CLARIDGE

CHEM / BCMB 4190/6190/8189. Introductory NMR. Lecture 10

4 Spin-echo, Spin-echo Double Resonance (SEDOR) and Rotational-echo Double Resonance (REDOR) applied on polymer blends

PROTEIN NMR SPECTROSCOPY

Laboration 8a. Relaxation, T 1 -measurement with inversion recovery

Operation of the Bruker 400 JB Stothers NMR Facility Department of Chemistry Western University

Spin Relaxation and NOEs BCMB/CHEM 8190

Spin Dynamics Basics of Nuclear Magnetic Resonance. Malcolm H. Levitt

Biophysical Chemistry: NMR Spectroscopy

Cross Polarization 53 53

Center for Sustainable Environmental Technologies, Iowa State University

NMR in Structural Biology

Slow symmetric exchange

Chemistry Department

Introduction to MRI. Spin & Magnetic Moments. Relaxation (T1, T2) Spin Echoes. 2DFT Imaging. K-space & Spatial Resolution.

Login -the operator screen should be in view when you first sit down at the spectrometer console:

Principios Básicos de RMN en sólidos destinado a usuarios. Gustavo Monti. Fa.M.A.F. Universidad Nacional de Córdoba Argentina

T 1, T 2, NOE (reminder)

1H 1D-NOE Difference Spectra and Spin-Saturation Transfer Experiments on the GN500

An introduction to Solid State NMR and its Interactions

NMR course at the FMP: NMR of organic compounds and small biomolecules - II -

General NMR basics. Solid State NMR workshop 2011: An introduction to Solid State NMR spectroscopy. # nuclei

NMR FACILITY NEWSLETTER

Principles of Nuclear Magnetic Resonance in One and Two Dimensions

NMR PRAKTIKUM. Data processing Data acquisition... 17

10.4 Continuous Wave NMR Instrumentation

Carbon 13 NMR NUCLEAR MAGNETIC RESONANCE SPECTROSCOPY

4 DQF-COSY, Relayed-COSY, TOCSY Gerd Gemmecker, 1999

NMR and MRI : an introduction

Timescales of Protein Dynamics

NMR Predictor. Introduction

Band-Selective Homonuclear 2D Correlation Experiments

Solid-state NMR and proteins : basic concepts (a pictorial introduction) Barth van Rossum,

Chemistry 431. Lecture 23

τ 1 > 1/J - if this lifetime is significantly shortened, the coupling (splitting of the signal) will not be observed

Determining C-H Connectivity: ghmqc and ghmbc (VnmrJ-2.2D Version: For use with the new Software)

Protein dynamics from NMR Relaxation data

Chapter 7. Nuclear Magnetic Resonance Spectroscopy

BMB/Bi/Ch 173 Winter 2018

Timescales of Protein Dynamics

Ferdowsi University of Mashhad

PRACTICAL ASPECTS OF NMR RELAXATION STUDIES OF BIOMOLECULAR DYNAMICS

Polarised Nucleon Targets for Europe, 2nd meeting, Bochum 2005

How to perform 2D NMR Experiments on the Varian/Agilent VNMRS 500 when using the Chempack interface

BASIC NMR HANDBOOK Written by M. A. Eastman Copyright 1997, 2001, 2013, 2015, 2018

CONTENTS. 2 CLASSICAL DESCRIPTION 2.1 The resonance phenomenon 2.2 The vector picture for pulse EPR experiments 2.3 Relaxation and the Bloch equations

Advanced Quadrupolar NMR. Sharon Ashbrook School of Chemistry, University of St Andrews

Supporting Information Elucidating Lithium-Ion and Proton Dynamics in Anti- Perovskite Solid Electrolytes

NMR BMB 173 Lecture 16, February

Carbon and Heteronuclear NMR on the Bruker

8.2 The Nuclear Overhauser Effect

e 2m p c I, (22.1) = g N β p I(I +1), (22.2) = erg/gauss. (22.3)

H-C one-bond correlations: HSQC Preliminaries.

NMR: PRACTICAL ASPECTS

Magnetic Resonance Spectroscopy

HMQC HSQC and HMBC. Gradient HMQC, HMBC on the Bruker400 and 500

Relaxation, Multi pulse Experiments and 2D NMR

NMR Spectroscopy Laboratory Experiment Introduction. 2. Theory

SSSC Discovery Series NMR2 Multidimensional NMR Spectroscopy

NMR-spectroscopy of proteins in solution. Peter Schmieder

More NMR Relaxation. Longitudinal Relaxation. Transverse Relaxation

Introduction to 1D and 2D NMR Spectroscopy (4) Vector Model and Relaxations

NMR Spectroscopy of Polymers

North Carolina State University Department of Chemistry Varian NMR Training Manual

Nuclear magnetic resonance spectroscopy II. 13 C NMR. Reading: Pavia Chapter , 6.7, 6.11, 6.13

Apparative Methoden in der Physikalischen Chemie DIFFUSION MEASUREMENTS BY NUCLEAR MAGNETIC RESONANCE (NMR) 1 Introduction.

Magnetic Resonance Imaging. Pål Erik Goa Associate Professor in Medical Imaging Dept. of Physics

Lab 1: Intro to NMR. March 10, 2014

X-Nucleus NMR: 31 P and 19 F

Fundamental MRI Principles Module Two

Magnetization Gradients, k-space and Molecular Diffusion. Magnetic field gradients, magnetization gratings and k-space

Physical Background Of Nuclear Magnetic Resonance Spectroscopy

Filtered/edited NOESY spectra

Spin-spin coupling I Ravinder Reddy

H-C one-bond correlations: HSQC Preliminaries.

NMR NEWS June To find tutorials, links and more, visit our website

Introduction to Relaxation Theory James Keeler

MRI Physics I: Spins, Excitation, Relaxation

Double-Resonance Experiments

Measuring Spin-Lattice Relaxation Time

Two Dimensional (2D) NMR Spectroscopy

K-space. Spin-Warp Pulse Sequence. At each point in time, the received signal is the Fourier transform of the object s(t) = M( k x

PRACTICAL ASPECTS OF NMR RELAXATION STUDIES OF BIOMOLECULAR DYNAMICS

TECNICHE DI ALTA E BASSA RISOLUZIONE IN NMR STATO SOLIDO

MEASURING DIFFUSION BY NMR. Bruker Instruments Inc. Sophie Kazanis Application Scientist August 2000

Chem 325 NMR Intro. The Electromagnetic Spectrum. Physical properties, chemical properties, formulas Shedding real light on molecular structure:

NMR TRAINING. What to Cover

Linear and nonlinear spectroscopy

Natural abundance solid-state 95 Mo MAS NMR of MoS 2 reveals precise 95 Mo anisotropic parameters from its central and satellite transitions

Correcting Lineshapes in NMR Spectra

Principles of Nuclear Magnetic Resonance Microscopy

NMR Data workup using NUTS

G Medical Imaging. Outline 4/13/2012. Physics of Magnetic Resonance Imaging

Advanced Topics and Diffusion MRI

NMR FACILITY User's Guide

The NMR Spectrum - 13 C. NMR Spectroscopy. Spin-Spin Coupling 13 C NMR. A comparison of two 13 C NMR Spectra. H Coupled (undecoupled) H Decoupled

EL-GY 6813/BE-GY 6203 Medical Imaging, Fall 2016 Final Exam

Relaxation times in nuclear magnetic resonance

Chem8028(1314) - Spin Dynamics: Spin Interactions

Transcription:

1

2

The study queue gives a lot of flexibility for lining up experiments: they can be run at different temperatures or at different times. You must respect the instrument limits: do not submit experiments for nuclei that the probe is not tuned to or which it cannot do. For example, on the 500, you cannot run fluorine without first manually tuning to it, so you cannot have a queue with both proton and fluorine experiments in it. The Varian 300, on the other hand, is always tuned to 1 H, 19 F, and 13 C. However, the Varian 300 has no VT controller, so you cannot submit VT experiments to it. It is possible to choose the temperature for each experiment by setting a temperature under the Temp pane (under the Standard panel). 3

Working manually in VnmrJ bypasses the occasional errors that occur with the Study Queue on the Varian 400 and 500. However, the standard acquisition command ga (or the Acquire button) does not save the spectrum automatically. You must save it yourself! Or, you can start acquisition with the command run. The parameter bs, for block scans, sets when the data is written to disk. For example, if bs = 8, then you can look at the data after only 8 scans, even if the number of scans, nt=10000. 4

The concentration of water in a solution of water is 110 M, easily obscuring standard NMR samples which are only present in mm concentration. 5

Mostly, either the saturation method or gradient methods are used, because it is very difficult to fail to excite the large water signal. Note that the signal-to-noise ratio has improved in the spectrum with water suppression. 6

Presaturation methods are reliable in that they do not depend upon exact calculations of any pulses, delays, gradients, etc. They need accurate adjustment of the presaturation position, but this can be automated. Attenuation of signals near the solvent peak being presaturated can be minimized by using a lower power for a longer duration, albeit at the cost of longer experiment time. 7

8

One side effect of introducing multiple pulses into a pulse sequence is that errors in the pulses tend to add, so that parts of the sample at the edges of the rf coil, which do not feel the full effect of the pulse applied, do not end up being excited. This is how the edge water is made to not show up in the spectrum. The Bruker experiment also looks for the largest signal automatically and suppresses it. 9

The key to all these sequences is that only the solvent signal experiences a net dephasing, or loss of signal, from the gradient pulse. The WATERGATE and excitation sculpting sequences use selective refocussing to select the signals other than water. These sequences do an excellent job of suppressing water, but the selective pulses used are long, and during the time which they are applied, J-coupled peaks become distorted. Thus, integrals are not as good with these sequences as with standard presat. 10

In the presence of a magnetic field gradient, spins evolve with frequencies that depend on their physical location in the sample. They yield no net signal at the end of a gradient pulse, because they all have different phases. 11

However, if a gradient pulse with opposite polarity but equal strength is applied for the same amount of time, the spins will evolve in exactly the opposite direction. Following that gradient pulse, their signal is said to be refocused. 12

The Bruker experiment 1d_DOUBSOLVSUPP uses NOESY-presat (like in single solvent version) to do decoupling. In both cases, a shaped pulse is generated which excites multiple sites. Exchangeable protons are still removed. 13

14

15

16

17

18

19

20

The NMR signal does not last forever, as can be seen from the decay apparent in most FIDs. In liquidstate NMR, as a rule, signal decays over a period of a few seconds. Two types of relaxation are important: T 1 relaxation, which is a return to equilibrium along the z axis, and T 2 relaxation, where coherence disappears in the transverse plane. In general, T 2 T 1. For small molecules, the two relaxation constants are nearly equal, but for large molecules like proteins, T 2 is considerably less than T 1. The main effect of T 1 is to limit the repetition rate of an experiment. For a 90 pulse in a simple pulse acquire experiment, if we wait 1xT1 between scans, the amount of magnetization that will have recovered is as follows: Assuming M z (eq)=1, M z (T1)= 1 1e -1, which is 1 1/2.718 = 0.63, i.e. 63% of the equilibrium z-magnetization remains. If we want 95% recovery, we need a delay of 3xT 1, and a delay of 5xT 1 will give 99.5% recovery. In practice, 3xT1 is usually sufficient. Longitudinal relaxation is stimulated by local magnetic fields oscillating with inverse correlation times close to the Larmor frequency, and is most efficient when the product of the Larmor frequency and the correlation time for molecular tumbling, w 0* t c =1. The main effect of T 2 appears in the linewidth. The longer T 2 is, the narrower the theoretically minimum linewidth is, which is why protein linewidths are greater than those of small molecules. However, the visible linewidth apparent in a spectrum is also affected by effects not intrinsic to the molecule, like magnetic inhomogeneity or bulk susceptibility (or poor shimming). This effect is known as T 2*. 21

Longitudinal relaxation is stimulated by motions at the Larmor frequency. As the tumbling rate decreases (the solution becomes more viscous or the molecule becomes larger), the spectral density function initially increases (the function is less spread out ) and T 1 decreases, but then as the rate falls further, the amount of highfrequency component falls and T 1 increases again. Transverse relaxation is stimulated by motions with inverse correlation times close to zero, and thus T 2 always decreases as molecular tumbling rate decreases. The actual origins of the fluctuating fields that cause relaxation include Interaction Dipolar coupling Quadrupolar coupling Paramagnetic interactions Scalar coupling Chemical shift anisotropy Spin rotation Relevant parameters Abundance of magnetically active nuclei: size of the magnetogyric ratio Electric field gradient at the nucleus Concentration of paramagnetic impurities Size of the J coupling Symmetry at the nuclear site Molecular motion 22

On the Varian instruments, this sequence can be set up by typing the command dot1. You will be prompted for the expected minimum T 1 value in seconds, the expected maximum T 1 value in seconds, and the time you want the experiment to take, in hours (use 0.1 if you want it to run as quickly as possible, with only 1 scan per τ value. This procedure can be used for any nucleus, once the instrument is set up to acquire a standard 1D spectrum for that nucleus. On the Bruker instruments, the setup is slightly more complicated, but it only needs to be done once; let me know before you need to run the experiment and I ll get it set up. As a rule of thumb, T 1 for 1 H in small molecules is usually a few seconds, if the sample hasn t been degassed (it s perhaps 10 s when the sample has been degassed) while it can range from a few seconds to 10-15 s for 13 C, increasing as the number of protons on the carbon decreases. 23

Note that the fit will not be as correct if the recycle delay used is not at least 3 times the actual T 1 value. To try to compensate for this, the decay curve is usually fit to the equation M z (t) = A(1 2e -t/t1 ), where A is an adjustable parameter, rather than to M z (t) = M eq,z (1 2e -t/t1 ), which helps a lot. 24

If the sample and magnetic field are perfectly homogeneous, the FID only becomes less intense because of transverse relaxation. In real samples, the line is broadened by poor shimming, sample inhomogeneity etc. To account for this, we need an experiment where chemical shift effects are eliminated during the relaxation period the spin-echo experiment. 180 pulses applied during the evolution will refocus the inhomogenous broadening the envelope at the refocus points will be the real T 2. 25

In a CPMG experiment, the magnetization decays during a delay t, then there is a 180 degree pulse, and the signal builds up again to an echo after a further time t, after which the signal is acquired. The experiment is incremented by increasing the number of echoes only the last echo is acquired. This incrementation is controlled by incrementing a loop counter. Note that the number of echoes should always be an even number, to compensate for errors in the 180 degree pulses. The delay between echoes should be <<1/J, but must be reasonably long compared to the 180 degree pulse length, to avoid sample heating/probe damage. 26

27

The DOSY experiment depends on the effect of a pair of gradient pulses in which the spins are made to precess in one direction during the first and in the other direction during the second. A gradient pulse creates a nonuniform magnetic field that varies linearly with distance along the NMR tube (the z direction). If the spins diffuse during time period D, then they will experience a different magnetic field during the second gradient pulse than during the initial gradient pulse. The result of this is that not all their intensity is refocused at the end of the second gradient pulse, so that the intensity of the NMR signal is modulated during signal detection. The diffusion constant of a molecule D is related to its shape by the Stokes- Einstein equation where k B is the Boltzmann constant, T is the temperature, h is the viscosity, and R H is the hydrodynamic radius of the molecule. 28

One of the early developments in DOSY was the use of the spin-echo (a 90-t- 180-t-acquire pulse sequence), using two gradients with the same sign, since the magnetisation was inverted between the two gradients. In this experiment, however, the magnetisation decayed with time constant T 2, not T 1. The amended stimulated echo sequence allows magnetisation to be stored along the z axis so that it decays with time constant T 1. As T 1 is almost always greater than T 2, this leads to greater signal intensity. The spoil gradient destroys magnetisation that is not returned to the z axis. 29

At the end of the STE sequence, the magnetisation is dephased in the transverse plane. After some time for the magnetisation to rephase, it is returned to the longitudinal axis and a decay period allows eddy currents to decay before the magnetisation is returned to the transverse plane for acquisition. 30

Replacing each gradient pulse with a pair of gradient pulses with opposite polarity refocuses static gradient terms, reducing the effect of eddy currents on the appearance of the final signal. 31

The goal in selecting big delta and little delta is to observe a large reduction in signal when gpz6 is large (95%), so that a strong gradient is applied, compared with when only a weak (gpz6=5%) gradient is applied. The three plots of signal intensity as a function of gradient strength are DOSY decay curves. They show, from left to right, a decay that is too slow, a decay that is too fast, and a decay that is appropriate; D and d can be neither too short nor too long to get the decay correct. Choosing D and d appropriately means that the decay curve will be described well over the full range of gradient strengths possible. 32

Experiment 5 in the multiple display window was run with gpz6=5%; experiment 6 was run with gpz6=95%. All other parameters were identical. 33

34

The Dynamics Center can usually be started from the Start Menu, under Start / All Programs / Bruker NMR Programs / Dynamics Center. On Linux, it can be found under Applications / Bruker TopSpin. The Dynamics Center also includes a component for analysing Protein Dynamics, but this requires a separate license. The Dynamics Center works using a method-based approach, in which each method (e.g. Diffusion) has a set set of steps, called the method tree, to follow. Each step has to be followed in order. 35

Click on Sample in the Diffusion method tree to start processing by entering information about the sample. Note that entering information here is optional, though it will appear on a report later. However, without at least clicking on Sample and clicking OK, it will not be possible to go on to the next step. Alternatively, drag and drop your dataset from a Windows explorer window (type expl in TopSpin for this) or straight from the Bruker data browser onto the word Diffusion in the Dynamics Center method tree. 36

Under the data entry in the method tree, you can choose the dataset you want to use and set some other parameters, such as those relating to peak picking. For the dataset, the default pseudo 2D (N traces) should be applicable if you have used the standard Bruker pulse sequences. Browse in the browser to the pdata number where you have processed the data using xf2. Once you have chosen the data and clicked on Open, you can verify that the diffusion parameters have been read correctly by looking at the DiffusionPar tab. 37

The spectrum will be displayed after the data is chosen. A toolbar permits you to see each trace of the spectrum. The peaks have been picked automatically, but if other peaks have to be picked or peaks have to be deleted, right-clicking will bring up an appropriate context-dependent menu. If the peak picking has failed totally, return to Data. Go to the peaks tab and choose threshold based peak picking. Left-click on the spectrum, hold the mouse button down, and release it when you are at an appropriate level for the threshold. The peaks displayed when you go on to the next step (Analysis) will be those used in the fitting, so make sure that the most intense trace is shown before continuing. 38

The default curve fitting function should be appropriate for the experiment you ran. Change the error estimation method to error estimation by weighted fit for more accurate error analysis. It is suggested that you calculate a 1D Inverse Laplace Transform (ILT) as a check on the diffusion curve fitting. 39

The fit is not displayed automatically. You must go to the View tab and click OK, although you can choose other options if you like. For the DOSY plot, the fit appears to have higher resolution if you set the number of points in F1 to a higher value. 40

Moving the cursor over any point shows its 1D ILT and 1D DOSY fit. Here, the agreement is excellent and the DOSY plot shows good resolution of pamoic acid from TMS, DMSO, and an impurity. The diffusion coefficients can be read off the 1D plot. For plotting purposes, you can export the 2D DOSY plot to Topspin as a 2rr file (so you can generate a PDF, for example) by right-clicking on it. When the 1D plots do not agree with each other, you should try to refit the data by increasing the range of the fit under Data / ILT / calculate 1D ILT. Try fitting from, for example, 1.0e-7 to 1.0e-13. You can always refit it later with a smaller range. Then, under View / DOSY plot, it might help to set the F1 display range manually to the same values you have selected. Once the two 1D plots are in good agreement, you can trust the D values displayed on the plot. 41

The report generation step is fairly self-explanatory. 42

The report contains a spectrum overview, the DOSY plot, and the diffusion coefficients, plus the 1D plots. The report tab allows this information to be customized. 43

The Dynamics Center allows information to be exported for use with other software. 44

For rigid molecules in a solid, anisotropic interactions dominate the spectrum because they are not averaged by isotropic motion. Such interactions include chemical shift anisotropy, dipolar coupling, and quadrupolar interactions. In the other extreme, isotropic interactions like the isotropic chemical shift (commonly called the chemical shift) and J-coupling dominate the spectra of liquids. In between, the spectra of inhomogeneous mixtures is dominated by magnetic susceptibility anisotropy, or the environment being different in every direction, although local anisotropic interactions are averaged by local motions. 45

Like a lightweight version of a solids probe, the nanoprobe spins samples at the magic angle (the angle of a cube) to average away anisotropic interactions and reduce them to their isotropic component. 46

47

48

49

The spectrum shows the chemical shift anisotropy (CSA) pattern of the two 13 C sites in glycine. The different width in the patterns reflects the greater anisotropy in the chemical shift at the carboxylic acid site than the methylene site. The actual shape of the line reflects the greater asymmetry in the chemical shift at the carboxylic acid site than at the methylene site. These patterns can be simulated and interpreted in terms of the electronic structure around each site. 50

The isotropic component is the average of the principal components of the CSA tensor. The anisotropic component is the distance between the isotropic component and the largest principal component. The anisotropy is a measure of the difference between the two smaller components. 51

The NMR experiment doesn t detect signal is the frame of the individual chemical shift tensor, but in the frame of the main magnetic field. Each crystallite in a powder is physically oriented differently in this frame, so each crystallite has a different resonance in the spectrum. The sum of all of the individual chemical shifts of each crystallite is the powder pattern shown in the CSA spectrum. 52

Magic-angle spinning narrows the lines of a spin-half nucleus significantly, and breaks the lines into spinning sidebands that are separated from the main peak (at the isotropic chemical shift) by the spinning frequency (in hertz). Residual linewidth is determined by: shimming (a well-shimmed liquid or highly mobile solid sample in a solids probe has a linewidth of a few Hz) magic angle setting (a poorly-set angle contributes 10 Hz or more to linewidth) decoupling (in a typical organic solid, residual coupling may broaden lines by 10-20 Hz) disorder in the sample (this factor is usually measured in ppm and varies greatly from sample to sample) T 2. In general, under MAS and with 1 H decoupling (if appropriate), lines should have a Lorentzian or Gaussian lineshape (depending on the degree of disorder or remaining dipolar coupling, where more disorder or dipolar coupling leads to a more Gaussian lineshape). The only exception to this rule is lines that are coupled to a quadrupolar nucleus. These lines exhibit a lineshape with clear features characteristic of so-called residual dipolar splitting, which results from the interaction of a dipolar and a quadrupolar tensor, which has an angular dependence that is not averaged to an isotropic value under spinning at the magic angle. This splitting is larger at lower field and gives rise to characteristic 1:2 doubles in carbonyl peaks in 13 C spectra of amino acids. The splitting arises from coupling to 14 N and is particularly apparent at fields of 400 MHz and below. Splitting from other quadrupolar nuclei may also be observed. 53

Homonuclear dipolar coupling is the through-space coupling of two of the same kind of nuclei. The main homonuclear dipolar coupling network, present in most organic molecules, is hydrogen (marked in black in the alanine shown in the slide). Because hydrogen is such high gamma and so abundant, it couples very strongly to other hydrogen atoms. This gives rise to very broad, inhomogeneous lines, both of the protons themselves, and of the nuclei coupled to them, because the protons form a network of spins. Homonuclear dipolar coupling may also be present among other nuclei such as 13 C or 29 Si, if the sample is isotopically labelled, or among 31 P or other nuclei. The strength of dipolar coupling scales with the gamma of the nuclei involved, so it is less strong in these cases than for 1 H, and lines can often still be narrow, especially under MAS, for these nuclei. Information contained in homonuclear dipolar coupling can be used to assign peaks by tracing a backbone through a sample. J coupling occurs between any pair of spin-active nuclei (homonuclear or heteronuclear). 54

55

Heteronuclear dipolar coupling is through-space coupling that occurs between two spin-active nuclei of different isotopes. The molecule shown here is alanine. The vertical red arrow shows the dipolar coupling between the CH 13 C and its attached proton. This coupling is what allows cross-polarisation, or sensitivity enhancement, to occur on 13 C: magnetisation is transferred from the high gamma (sensitive) proton to the lower gamma (less sensitive) 13 C. The horizontal green arrow shows heteronuclear dipolar coupling between the CH 13 C and the 15 N to which it is attached. This coupling can be used to give information about the bond linking the 15 N and the 13 C, but there is a sensitivity issue: 13 C is naturally only 1% abundance, while 15 N has only 0.3% natural abundance. So, unless the sample is labelled in both the 13 C and 15 N sites, obtaining information about the bond length will be very difficult. Usually, protein samples are run fully labelled for just this reason. 56

57

58

Some of the main heteronuclear proton decoupling techniques are shown here. Continuous wave (CW) decoupling methods work, as they do in solution-state NMR, by saturating the 1 H resonances so that coupling between an X nucleus and the 1 H is disrupted and the X nucleus resonance is not split by coupling to the 1 H. Both dipolar and J coupling are removed by this method. In general, 1 H decoupling is more efficient as higher proton power is applied, and decoupling at 100 khz (2.5 μs 90 ) is not uncommon. However, continuous wave decoupling is not very efficient, so other methods have been developed that are more efficient and more broadband (in short, more effective) than continuous wave decoupling. TPPM (two-pulse phase modulation) is a variation of CW decoupling in which the phase changes between 0 and 15 (or some other value) while high power is maintained continuously. The length of each pulse is approximately 180 but must be optimized for each sample. A further development of this technique is SPINAL (small phase incremental alternation), in which phases are changed and alternated in a more complicated (supercycled) pattern to remove higher-order coupling components. A different technique is the XiX (X-inverse X) method, in which 180 pulses alternate between x (0 ) and x (180 ). This sequence tends to be more widely used with faster MAS. 59

60

61

62

63

CP at various times, dipolar dephasing, non-quaternary suppression 64

65

Spin-half nuclei are those in yellow or pink in the periodic table above. They include: 1 H, 13 C, 15 N, 19 F, 29 Si, 31 P, 57 Fe, 77 Se, 89 Y, 103 Rh, 109 Ag (and 107 Ag), 113 Cd, 119 Sn (and 115 Sn and 117 Sn), 125 Te (and 123 Te), 129 Xe, 183 W, 187 Os, 195 Pt, 199 Hg, 205 Tl (and 203 Tl), 207 Pb, 209 Bi, 209 Po and 171 Yb. That is, there are not many nuclei with spin ½, but those nuclei with spin ½ occur frequently in a wide variety of compounds: 1 H, 13 C, and 15 N in organic compounds, 31 P and 29 Si in minerals, and 19 F in pharmaceutical compounds and glasses, to name but a few nuclei and applications! Unlike in liquid-state NMR, 1 H spectra tend to be broad and featureless, giving little to no information about a sample, while The considerations to take account of when deciding whether a spin-half nucleus will lend itself to investigation are its frequency, natural abundance, and relaxation properties. The greater the NMR frequency, the more sensitive is NMR. Probe capabilities, too, determine whether a nucleus can be studied on a particular setup. The natural abundance of a particular isotope can limit the applicability of NMR studies to a particular nucleus, and even if an isotope is present in great enough abundance to make NMR possible, it may not be abundant enough to make correlation experiments (linking two nuclei) possible. Finally, a nucleus that has a very long T 1 can be painful to study, while a very short T 2 leads to broad lines and signal lost in the probe dead time (the delay between the final pulse and the start of acquisition). Problems of abundance and long relaxation can frequently be overcome if the site of interest is near nuclei that are highly abundant and sensitive (such as protons), as will be shown in the slides about CP. 66

67

68

69

70

71

72

73

74