2d-Laser Cantilever Anemometer

Similar documents
and Joachim Peinke ForWind Center for Wind Energy Research Institute of Physics, Carl-von-Ossietzky University Oldenburg Oldenburg, Germany

6. Laser Doppler Anemometry. Introduction to principles and applications

Laser Doppler Anemometry. Introduction to principles and applications

Chapter 2 Correlation Force Spectroscopy

DESIGN AND CONSTRUCTION OF A WATER TUNNEL. Stephen C. Ko

Laser-Cantilever-Anemometer A new high resolution sensor for air and liquid flows

Experimental Aerodynamics. Experimental Aerodynamics

Lecture 20. Measuring Pressure and Temperature (Chapter 9) Measuring Pressure Measuring Temperature MECH 373. Instrumentation and Measurements

On the Use of Hot-Film Sensors in the Investigation of Fluid Dynamic Phenomena in the Near-Wall Region

Digital processing of multi-mode nano-mechanical cantilever data

Effects of screens set characteristics on the flow field in a wind tunnel.

Lecture 4 Scanning Probe Microscopy (SPM)

Development of Laser Thickness Gauge in Steel Plate Shearing Line

International Conference on Methods of Aerophysical Research, ICMAR 2008

6. Laser Doppler Anemometry. Introduction to principles and applications

APPENDIX 1 DESCRIPTION OF HOT WIRE ANEMOMETER

Burner Tubing Specification for the Turbulent Ethylene Non-Premixed Jet Flame

And Manipulation by Scanning Probe Microscope

On the correlation of the acoustic signal of microphones mounted on a flat plate to the turbulence of an impinging jet

(Refer slide Time 1:09)

Lorentz Contact Resonance for viscoelastic measurements of polymer blends

Lorentz Contact Resonance for viscoelastic measurements of polymer blends

More Optical Telescopes

Lecture 19. Measurement of Solid-Mechanical Quantities (Chapter 8) Measuring Strain Measuring Displacement Measuring Linear Velocity

Those data on the time required for the pitch to traverse various distances were measured in

custom reticle solutions

Understanding Hot-Wire Anemometry

Ruby crystals and the first laser A spectroscopy experiment

NIS: what can it be used for?

Confocal Microscopy Imaging of Single Emitter Fluorescence and Hanbury Brown and Twiss Photon Antibunching Setup

Module 3: Velocity Measurement Lecture 16: Validation of PIV with HWA. The Lecture Contains: Hotwire Anemometry. Uncertainity

Special edition paper

Determining thermal noise limiting properties of thin films

Measurement method for the proficiency testing program

Introduction. Procedure. In this experiment, you'll use the interferometer to EQUIPMENT NEEDED: Lens 18mm FL. Component holder.

MEASUREMENT OF THE FRICTION AND LUBRICITY PROPERTIES OF CONTACT LENSES

Instrumentation and Operation

Welcome to the world of wind energy. Wind Potential. Dr. D. V. Kanellopoulos OPWP Renewable Energy Training Program December 2016 Muscat, Oman

ENSC387: Introduction to Electromechanical Sensors and Actuators LAB 3: USING STRAIN GAUGES TO FIND POISSON S RATIO AND YOUNG S MODULUS

x Contents Segmented Mirror Telescopes Metal and Lightweight Mirrors Mirror Polishing

Robust and Miniaturized Interferometric Distance Sensor for In-Situ Turning Process Monitoring

Electronic Supplementary Information

Application of an ultrasonic velocity profile monitor in a hydraulic laboratory

Calibrating the Thermal Camera

Development of PC-Based Leak Detection System Using Acoustic Emission Technique

Sensors and Transducers. mywbut.com

Principle And Practice Of Hotwire Anemometry In Turbomachinery Applications

Cantilever enhanced tunable diode laser photoacoustic spectroscopy in gas purity measurement case study: acetylene in ethylene

Modeling Airplane Wings

ACTIVE SEPARATION CONTROL ON A SLATLESS 2D HIGH-LIFT WING SECTION

Simple Harmonic Motion and Damping

7. CONCLUSIONS & SCOPE

Fundamentals of Low Intensity Shock Calibration

Mechatronics II Laboratory EXPERIMENT #1: FORCE AND TORQUE SENSORS DC Motor Characteristics Dynamometer, Part I

Silicon Capacitive Accelerometers. Ulf Meriheinä M.Sc. (Eng.) Business Development Manager VTI TECHNOLOGIES

Study of Solder Ball Bump Bonded Hybrid Silicon Pixel Detectors at DESY

Week 14 The Simple Pendulum

CUSTOM RETICLE SOLUTIONS

CHAPTER 4 OPTIMIZATION OF COEFFICIENT OF LIFT, DRAG AND POWER - AN ITERATIVE APPROACH

Fourier Transform Spectrograph Development Project

Determine the Inside Wall Temperature of DSTs using an Infrared Temperature Sensor

Background Information for Use of Pitot Tube, Manometer, Hot Wires, and Hot Films

NIHON. Experimental and Computational Study of Boundary Layer Transition by Two-Dimensional Roughness (January 1997) NIHON

INTEGRATED COOLING CHANNELS IN POSITION-SENSITIVE SILICON DETECTORS

Alignment Tools Used To Locate A Wire And A Laser Beam In The VISA Undulator Project

FIELD INSTRUMENTATION AND ANALYSIS OF PROTOTYPE AND EXISTING LIGHT POLES ON THE BRONX-WHITESTONE BRIDGE. Final Report. Ian C. Hodgson.

Basic Laboratory. Materials Science and Engineering. Atomic Force Microscopy (AFM)

INFLUENCE OF ACOUSTIC EXCITATION ON AIRFOIL PERFORMANCE AT LOW REYNOLDS NUMBERS

Windcube TM Pulsed lidar wind profiler Overview of more than 2 years of field experience J.P.Cariou, R. Parmentier, M. Boquet, L.

STRAIN GAUGES YEDITEPE UNIVERSITY DEPARTMENT OF MECHANICAL ENGINEERING

Catapult tests for microgravity characterization of the MICROSCOPE accelerometers. Manuel Rodrigues On behalf ONERA & ZARM team

Supplemental material for Bound electron nonlinearity beyond the ionization threshold

Foundations of MEMS. Chang Liu. McCormick School of Engineering and Applied Science Northwestern University. International Edition Contributions by

THE MICHELSON INTERFEROMETER Intermediate ( first part) to Advanced (latter parts)

The Principles of Astronomical Telescope Design

PART 1B EXPERIMENTAL ENGINEERING. SUBJECT: FLUID MECHANICS & HEAT TRANSFER LOCATION: HYDRAULICS LAB (Gnd Floor Inglis Bldg) BOUNDARY LAYERS AND DRAG

AN INSTRUMENT FOR THE MEASUREMENT OF ROAD SURFACE REFLECTION PROPERTIES

MEASUREMENTS IN BLADE CASCADE FLOW. David Krivánka

Piezoelectric Actuator for Micro Robot Used in Nanosatellite

Digital Holographic Measurement of Nanometric Optical Excitation on Soft Matter by Optical Pressure and Photothermal Interactions

High Reynolds Number Wall Turbulence: Facilities, Measurement Techniques and Challenges

Speckles and adaptive optics

Anemometry Anemometer Calibration Exercise

This article appeared in a journal published by Elsevier. The attached copy is furnished to the author for internal non-commercial research and

Recent improvement of the LHD Thomson scattering system

Courtesy of ESS and TheRGA web pages part of a series of application and theory notes for public use which are provided free of charge by ESS.

Flow disturbance due to presence of the vane anemometer

A Laser-Compass Magnet Probe for Field Measurements in Solenoids

Micromechanical Instruments for Ferromagnetic Measurements

Fan Stage Broadband Noise Benchmarking Programme

Supplementary Figures

SENSOR. Weather TRANSMITTERS

Micro-sensors based on thermal transduction for steady and unsteady flow measurements

Detection of trace contamination on metal surfaces using the handheld Agilent 4100 ExoScan FTIR

LAB 3: Confocal Microscope Imaging of single-emitter fluorescence. LAB 4: Hanbury Brown and Twiss setup. Photon antibunching. Roshita Ramkhalawon

Application example. Measuring Force Sensors Rigid. Six series Nano, Mini, Gamma, Delta, Theta, Omega. Range of measurement, force ± 36 N..

Vacuum Kelvin Force Probe Research Richard Williams August 1st 2008

SUPPLEMENTAL MATERIAL Dynamic Similarity of Oscillatory Flows Induced by Nanomechanical Resonators

= 6 (1/ nm) So what is probability of finding electron tunneled into a barrier 3 ev high?

Heat Transfer from a Single, Heated Block

Transcription:

2d-Laser Cantilever Anemometer Introduction Measuring principle Calibration Design Comparative measurement Contact: Jaroslaw Puczylowski University of Oldenburg jaroslaw.puczylowski@forwind.de

Introduction In the following, a new type of anemometer is presented. The so-called 2d-Laser Cantilever Anemometer (2d-LCA) has been developed at the University of Oldenburg over the last 10years. It utilizes a sensitive measuring principle that was adopted from atomic force microscopy. The main motivation for the development of the 2d-LCA was a lack of highly-resolving anemometers that are suitable for operation in a wide range of different flow conditions. These include liquids, particle-laden flows and near-wall flows. Another important aspect is the demand for a robust and reliable alternative for commercial standard x-wires, which are commonly used for measurements of turbulent flows under laboratory conditions.

Measuring principle A micro-structured cantilever is brought into the flow. The drag force acting upon the cantilever causes a deformation, which contains the information of the flow velocity and flow direction. Fluid inflow Cantilever 2d-PSD The deformation is gathered using the laser leaver arm principle. For this purpose a laser is directed onto the tip of the cantilever. The reflected light is tracked by means of a two-dimensional position sensitive detector (2d-PSD). Beam splitter Laser

Measuring principle The total deformation of the cantilever is a superposition of bending and twisting. Bending arises from a straight inflow, i.e. angle of attack AOA=0, whereas additional twisting is observed for AOA 0. In this manner simultaneous measurements of two velocity components are possible.

Calibration The calibration is performed in a wind tunnel or in any other commercially available calibration unit. Wind tunnel Outlet 2d-LCA 2d-LCA During the calibration process the positions (x- and y-components) of the reflecting light spot along the 2d-PSD are recorded for different inflow velocities and angles of attack. Turning table A calibration plane is obtained by plotting the recorded positions for each velocity and angle of attack.

Calibration +90 The calibration plane of the 2d- LCA is shown for velocities ranging from 4- and AOA of +/-90. The points indicate the collected data during calibration. Red and blue lines connect points that correspond to equal velocities and AOA, respectively. For reasons of clarity few points (highlighted in green) are labeled. relative y-component +45 0-45 -70 10m/s 0 4m/s -90 relative x-component

Calibration In comparison to a calibration plane of a standard x-wire (type Dantec P51) the 2d-LCA calibration remains unique for the entire angular range of +/-90. 2d-LCA 2d-LCA +40 X-wire 0 The x-wire calibration collapses for AOA exceeding the range of about +/-40. 0 0 4m/s 0 4/s -40 It should be noted that the velocity resolution (distances between red lines) increases for the 2d-LCA and decreases for the x-wire with increasing inflow velocity.

Cantilever design The cantilever chip is microstructured using lithography techniques. It is attached to the front face of a triangular-shaped structure. The cantilever is made of silicon (Si) and features a vane, which is made of SU8. The vane increases the sensitivity towards crosswinds, i.e. amplifies the amount of twisting due to lateral forces. The dimensions of the cantilever are (140-180)µm x 40µm x 1.2µm (L x W x T).

Resolution The temporal resolution of the 2d-LCA is limited by the first resonant mode of the cantilever. The first resonant modes for two cantilevers (with vane and without vane) of equal lengths of 140µm were identified experimentally to be 63kHz and 100kHz. For this purpose, both cantilevers were d r i v e n u s i n g e l e c t r o s t a t i c excitation at continuous sweeping frequencies up to 140kHz. The amplitudes of the cantilevers were monitored using interferometry.

Resolution The spatial resolution of the 2d- LCA corresponds to the largest dimension of the cantilever, which is the length of 120µm, 140µm or 160µm (depending on the design of the cantilever) length

Anemometer design The housing of the 2d-LCA is made of aluminum and measures about 22cm in length. The anemometer is equipped with two DC-motors and various adjustable mechanisms that are used for alignment of the laser and the cantilever. Cantilever arm Mirror mount Slide Mirror mount Ground plate DC-motors housing The cantilever is attached to the tip of the cantilever arm. Cantilever Cap

Anemometer design The whole measuring technique is housed in one small box. This box includes an amplifier, lowpass filters, controls for the laser adjustment and an fast A/D-converter (6ch., 16bit, max. 150kHz/ch.). The output signal is transmitted via USB to a computer (software for LabView is included). 4 input channels are available for additional sensors, thus providing an easy way for simultaneous measurements. The system is very compact, lightweight and can also be operated with batteries. In combination with a notebook it is highly portable. By contrast to hot-wire anemometry no costly signal conditioning is needed for the 2d-LCA. This is mainly due to the optical isolation of the sensing element (hot-wires are active components of the electronics and transfer external noise to the signal processing unit).

Performance Some measurements in turbulent flow with two 2d-LCAs (with vane and without vane) and a standard x-wire (Dantec type P51) were performed. The measurements were conducted in a wind tunnel at a velocity of. A cylinder has been used to generate turbulent flow (Re 15800). The time series of the angle of attack and the absolute value of velocity are used for a quick comparison. Since all anemometers are separated by a distance of about 20cm an exact course of all trajectories is not expected. Nevertheless, the plots show that the shapes and dynamics of all time series look very similar.

Performance The power spectra of the longitudinal velocity component show good agreement within the inertial range. All spectra have a comparable dynamic range although the slope within the dissipation range slightly differs. Both 2d-LCA spectra do not show any noise in the high frequency region.

Performance The probability density functions (PDFs) of velocity increments are shown for time steps τ 1 =3s, τ 2 =0.33s, τ 3 =1.7ms, τ 4 =0.34ms and τ 5 =0.17ms (bottom to top). Again, a good agreement between a l l t h r e e a n e m o m e t e r s i s observed.

Summary of features of the 2d-LCA and a standard x-wire 2d-LCA X-wire temporal resolution ~ 60-100kHz ~ 40-100kHz spatial resolution 140-180µm ~1250µm (for instance Dantec p51) range of velocities from ~ 1m/s ~ 0.5-150m/s range of angles of attack +/- 90 (relative to sensor) ~ +/- 45 (relative to sensor) accuracy cost sensor signal is proportional to v 2, therefore the accuracy increases for higher velocities low cost because no complex electronics needed (not for sale yet) sensor signal follows King s law and loses accuracy towards higher velocities ~ USD 50.000 (including Dantec Streamline and CTAs)

2d-LCA for atmospheric use (2d-ALCA) The measuring principle of the 2d-ALCA is exactly the same as for the 2d-LCA. However, a more robust cantilever made of stainless steel (with gold coating) is used to allow for measurements in rough atmospheric environments. The larger size of the cantilever (about 1mm in length) provides a higher stability at the expense of temporal resolution (~10kHz). Two prototypes of the 2d-ALCA were successfully tested in the field and during a measuring campaign at the off-shore met mast FINO3.