Euramet EM-S40. Bilateral Comparison KIM-LIPI / LNE. Final Report

Similar documents
ANNEXE 8. Technical protocols for the interlaboratory comparisons

Ajchara Charoensook, Chaiwat Jassadajin. National Institute of Metrology Thailand. Henry Chen, Brian Ricketts and Leigh Johnson

Supplementary Comparison EURAMET.EM-S19 EURAMET Project No. 688

Comparison of V and 10 V DC Voltage References

BUREAU INTERNATIONAL DES POIDS ET MESURES

BUREAU INTERNATIONAL DES POIDS ET MESURES

Final Report August 2010

Final Report 06 July 2006 Frank Wilkinson, Gan Xu, and Yuanjie Liu

INTERNATIONAL COMPARISON OF PLATINUM RESISTANCE THERMOMETERS BETWEEN CHILE AND ECUADOR

AFRIMETS. Supplementary Comparison Programme. Calibration of Gauge Blocks. by Mechanical Comparison Method AFRIMETS.L S3.

The Journey from Ω Through 19 Orders of Magnitude

Comparison protocol EURAMET project

Final Report EUROMET PROJECT 818 CALIBRATION FACTOR OF THERMISTOR MOUNTS. Jan P.M. de Vreede

Report on Key Comparison COOMET.AUV.A-K5: Pressure calibration of laboratory standard microphones in the frequency range 2 Hz to 10 khz

by A.Tonina*, R.Iuzzolino*, M.Bierzychudek* and M.Real* S. Solve + R. Chayramy + and M. Stock +

Final Report. CCEM Comparison of 10 pf Capacitance Standards. Anne-Marie Jeffery Electricity Division NIST May 2000 Revised March 2002

Final Report on APMP.M.M-K4.1 - Bilateral Comparison of 1 kg Stainless Steel Mass Standards between KRISS and A*STAR

Technical Protocol of the CIPM Key Comparison CCAUV.V-K5

Final Report. APMP.EM-K4.1 APMP Key Comparison of Capacitance at 10 pf

Bureau International des Poids et Mesures, Sèvres, France. *KEBS, Kenya Bureau of Standards P.O. Box , Nairobi, Kenya

Comparison of measurement uncertainty budgets for calibration of sound calibrators: Euromet project 576

CERTIFICATE OF CALIBRATION

EA Guidelines on the Calibration of Temperature Indicators and Simulators by Electrical Simulation and Measurement

Document No: TR 12 Issue No: 1

Supplementary Comparison EUROMET.EM-S23 EURAMET PROJECT No 815 FINAL REPORT

Final Report on COOMET Key Comparison of Capacitance at 10 pf (COOMET.EM-K4)

APMP.T-K3.4: Key comparison of realizations of the ITS-90 over the range C to C

EUROMET Comparison of a 10 mh Inductance Standard at 1 khz EUROMET.EM-K3. Final Report

RECENT ILC ACTIVITY IN ROMANIAN MASS MEASUREMENTS

Final Report on the Torque Key Comparison CCM.T-K2 Measurand Torque: 0 kn m, 10 kn m, 20 kn m Dirk Röske 1), Koji Ogushi 2)

Technical Protocol of the Bilateral Comparison in Primary Angular Vibration Calibration CCAUV.V-S1

FINAL REPORT Bilateral Comparison of DC Magnetic Flux Density Between NML-SIRIM and KRISS

SIM.EM-K2, 1 GΩ SIM.EM-S6, 1 MΩ. RMO COMPARISON FINAL REPORT R. E. Elmquist, D. G. Jarrett, and N. F. Zhang

by S. Solve +, R. Chayramy +, M. Stock +, D. Vlad*

Analysis of interlaboratory comparison when the measurements are not normally distributed

Appendix B1. Reports of SMU

BUREAU INTERNATIONAL DES POIDS ET MESURES. Comparison of Quantum Hall Effect resistance standards of the PTB and the BIPM

JAB NOTE4. ESTIMATION OF MEASUREMENT UNCERTAINTY (Electrical Testing / High Power Testing) Japan Accreditation Board (JAB)

High pressure comparison among seven European national laboratories

Lab E3: The Wheatstone Bridge

BILATERAL COMPARISON REPORT LNE KIM-LIPI

EUROMET Project 702 EUROMET.M.D-K4

R SANAS Page 1 of 7

Interamerican Metrology System (SIM) Regional Metrology Organization (RMO) Capacitance Comparison, Final Report

792A AC/DC Transfer Standard

Metrology Principles for Earth Observation: the NMI view. Emma Woolliams 17 th October 2017

A bilateral comparison of a 1 kg platinum standard

Operational Amplifiers

APMP Key Comparison of DC Voltage at V and 10 V

EA-10/13. EA Guidelines on the Calibration of Temperature Block Calibrators. Publication Reference PURPOSE

Final Report CCEM.RF-K8.CL COMPARISON CALIBRATION FACTOR OF THERMISTOR MOUNTS. Jan P.M. de Vreede

EURAMET Project no Inter-comparison of a 1000 L proving tank

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

ANALYSIS OF MSL TG-13 PRESSURE GAUGE CALIBRATION METHOD

792A AC/DC Transfer Standard

OIML D 28 DOCUMENT. Edition 2004 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION. Conventional value of the result of weighing in air

IMPROVING SOIL MEASUREMENTS FOR BOUNDARY LAYER RESEARCH

INTERLABORATORY MASS COMPARISON BETWEEN LABORATORIES BELONGING TO SIM SUB-REGIONS COORDINATED BY CENAM (SIM.7.31a & SIM.7.31b)

Calibration of Temperature Block Calibrators

Bilateral National Metrology Institute Comparison of Guarded-Hot-Plate Apparatus

CCQM-K45: Sn in tomato paste key comparison

The quantised Hall resistance as a resistance standard

Euramet project 1187 Comparison of Instrument Current Transformers up to 10 ka. Technical protocol (March 2012)

Electricity and Magnetism Supplementary Guide for the Submission of CMCs

GB/T / IEC 60093:1980

Evaluation. of the Uncertainty. of Measurement. In Calibration

High pressure comparisons between seven European National Laboratories

ASIA PACIFIC METROLOGY PROGRAME

Low Frequency Electrical Metrology Programs at NIST

Analysis of a national low dc resistance inter-laboratories comparison

EDITION 1 OCTOBER 1997 EA-10/09 PAGE 1 OF

CALIBRATION REPORT FOR THERMOHYDROMETER

For the National Voluntary Laboratory Accreditation Program

MASS AND VOLUME COMPARISONS AT MIKES

Final report on CCQM-K36.1 with erratum

Pascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure

Conventional Paper I-2010

CALYS 80P. Field pressure calibrator with high accuracy 0.01%

Final Report On COOMET Vickers PTB/VNIIFTRI Key Comparison (COOMET.M.H- K1.b and COOMET.M.H- K1.c)

19:00 21:30 Registration and reception at Hotel ETAP Altinel. Welcome

BRIDGE CIRCUITS EXPERIMENT 5: DC AND AC BRIDGE CIRCUITS 10/2/13

Guidelines on the Calibration of Automatic Instruments for Weighing Road Vehicles in Motion and Measuring Axle Loads AWICal WIM Guide May 2018

NIST CERTIFICATION OF ITS-90 FIXED-POINT CELLS FROM K TO K: METHODS AND UNCERTAINTIES

Low gauge pressure comparisons between MIKES, Metrosert and FORCE Technology

Portuguese Institute for Quality. Contents

COMPARISON OF HUMIDITY MEASUREMENTS USING A DEW POINT METER AS A TRANSFER STANDARD APMP-IC-1-97 REPORT

Force Key Comparison EUROMET.M.F-K2. (50 kn and 100 kn) EURAMET Project No 518. Final Report. 14 July Pilot: NPL, United Kingdom

FINAL REPORT. RMO Key Comparison EUROMET.EM-K2 Comparison of Resistance Standards at 10 M and 1 G. Beat Jeckelmann and Markus Zeier

Introduction to the evaluation of uncertainty

1 Phone , fax , 2 Phone , fax ,

CALYS 120 IS. ATEX documenting multifunction calibrator with high accuracy 0.006%

PHYS 2212L - Principles of Physics Laboratory II

EA-10/14. EA Guidelines on the Calibration of Static Torque Measuring Devices. Publication Reference PURPOSE

INC 331 Industrial Process Measurement. Instrument Characteristics

The Determination of Uncertainties in Bend Tests on Metallic Materials

INTERLABORATORY COMPARISON BETWEEN TUBITAK-UME TURKEY AND INM ROMANIA IN THE FIELD OF FORCE MEASUREMENTS

TYPICAL PRESSURE MEASUREMENT UNCERTAINTY DEFINED BY AN FPG8601 FORCE BALANCED PISTON GAUGE

National Physical Laboratory Hampton Road Teddington Middlesex United Kingdom TW11 0LW

I. Yang, C. H. Song, Y.-G. Kim & K. S. Gam

Establishing traceability and estimating measurement uncertainty in physical, chemical and biological measurements

Transcription:

DC resistance 1 mω, 100 Ω and 100 MΩ Bilateral Comparison KIM-LIPI / LNE Final Report Isabelle BLANC Laboratoire national de métrologie et d essais (LNE) 9 avenue Roger Hennequin F-78190 Trappes (France) 0 novembre 014

Abstract: This report describes a bilateral comparison of resistance standards organised within the frame of the EU-Indonesia Trade Support Program II (TSP) / AWP--0-5 between LNE, France and KIM-LIPI, Indonesia. This bilateral comparison registered in the KCDB as EURAMET.EM-S40 was piloted by LNE. LNE participated in CCEM Key Comparison CCEM-K10 and CCEM-K, thus providing the link between KIM-LIPI results and CCEM-K10 and CCEM-K. This report includes the measurement results from the participants and information about their calibration methods for measurements of 1 mω, 100 Ω and 100 MΩ resistors. Content 1 INTRODUCTION... 3 DEFINITION OF THE MESURAND... 3 3 TRAVELLING STANDARDS... 4 3.1 Description of the standards... 4 3. Characterization of the standards... 4 3..1 Effect of temperature... 4 3.. Drift... 5 3..3 Effect of current... 5 3..4 Other characteristics... 6 4 DESCRIPTION OF THE INTERLABORATORY COMPARISON AND ORGANIZATION... 6 4.1 Organization of the interlaboratory comparison... 6 4. Coordinator and Participants of the comparison... 6 4.3 Time schedule... 6 4.4 Instructions... 7 5 METHOD OF MEASUREMENTS... 7 5.1 LNE method... 7 5.1.1 Method... 7 5.1. Reference standards and source of traceability... 9 5. KIM-LIPI... 10 5..1 Method... 10 5.. Reference standards and source of traceability... 11 6 CHARACTERIZATION OF THE REFERENCE VALUE... 11 6.1 Determination of the comparison reference value... 11 6. Reference value of the comparison... 11 7 MEASUREMENT RESULTS... 1 7.1 Resistance 1 mω... 1 7. Resistance 100 Ω... 14 7.3 Resistance 100 MΩ... 15 8 DISCUSSION OF THE RESULTS... 15 9 DEGREES OF EQUIVALENCE OF KIM LIPI... 16 9.1 Degrees of equivalence (DoE) between LNE and KIM-LIPI... 16 9. Link to the CCEM Key comparison... 16 10 CONCLUSION... 17 11 APPENDICES... 17 Final report Nov 0 th, 014 Page of 34

Supplementary Comparison EURAMET EM-S40 Bilateral comparison of DC resistance standards (1 mω, 100 Ω and 100 MΩ) 1 INTRODUCTION The comparison is organised within the EU-Indonesia Trade Support Programme II, Sub-project Number AWP--0-5, Improvement of traceability of Metrology and Calibration measurements of Puslit KIM. Two National Metrology Institutes took part in this comparison: LNE (France) and KIM-LIPI (Indonesia). LNE is acting as the pilot laboratory and in this function is responsible for providing the travelling standard, the evaluation of the measurement results and the final report. The objective of this comparison is to compare the measurement capabilities of the two National Metrology Institutes for 3 values of resistances : 1 mω, 100 Ω and 100 MΩ. The comparison is linked to the CCEM comparisons CCEM-K10 and CCEM-K by the participation of LNE to these two comparisons. It is aimed to validate the competence of the KIM-LIPI to measure accurately DC resistance within their KCDB and/or accreditation uncertainties. This bilateral comparison was registered in the KCDB as EURAMET.EM-S40 in May 014. The comparison is accomplished in accordance with the EURAMET Guidelines on Conducting Comparisons and CCEM Guidelines for Planning, Organising, Conducting and Reporting Key, Supplementary and Pilot Comparisons. DEFINITION OF THE MESURAND The quantity to be measured is the resistance of the travelling standards in the 4 terminals configuration for the 1 mω and the 100 Ω standards and in the 3 terminals configuration for the 100 MΩ standard. Participants were asked to measure and report additional quantities. 1 mω and 100 Ω resistances: I: DC current through the resistor. T ext : the temperature ( C) of the environment where the standard is measured. 100 MΩ resistance: V: test voltage. T ext : the temperature ( C) of the environment where the standard is measured. RH ext : relative humidity of the environment. Final report Nov 0 th, 014 Page 3 of 34

3 TRAVELLING STANDARDS 3.1 DESCRIPTION OF THE STANDARDS The travelling standards were 3 resistors: YEW, type 79-1 mω - s/n 58FS1075. Guildline 9330-100 Ω - s/n 51.51. Guildline 9330-100 MΩ - s/n 61.890. The devices were chosen with respect to stability and repeatability prior to the start of the comparison. Preliminary measurements were performed to evaluate effect of temperature and power. 3. CHARACTERIZATION OF THE STANDARDS 3..1 Effect of temperature The temperature coefficients (CTs) were determined experimentally. From calibrations performed at 3 temperatures (0 C, 3 C and 6 C), the characteristics parameters R to, α to and β of the equation have been calculated: where R t and R t0 represent the values of the resistance at the temperatures t and t 0 (Tab 1). The value t 0 is fixed at 3,00 C: R = R t t o [ 1 + α (t-to) + β(t -to) ] t o Resistance R 3 α 3 (10-6 / C) β (10-6 / C ) YEW, type 79 1 mω - s/n 58FS1075 1,000078 mω + 9,81-0,57 Guildline 9330-100 Ω - s/n 51.51 100,001613 Ω + 0,37-0,03 Guildline 9330-100 MΩ - s/n 61.890 100,0048 MΩ + 3, - 0,3 Tab 1 Temperature coefficients Final report Nov 0 th, 014 Page 4 of 34

3.. Drift Measurements were performed prior to the comparison. The drift (µω/ω per year) has been then evaluated (Tab ). Resistance Drift (µω/ω per year) YEW, type 79-1 mω - s/n 58FS1075 +,9 Guildline 9330-100 Ω - s/n 51.51-0,1 Guildline 9330-100 MΩ - s/n N 61.890 -, Tab Drift of the travelling standards 1.000068 1.000066 1.000064 1.00006 Resistance value (milliohms) 100.00170 100.00165 100.00160 Resistance value (ohms) 1.000060 100.00155 1.000058 03/10/013 0/03/014 30/07/014 7/1/014 100.00150 03/10/013 0/03/014 30/07/014 7/1/014 Fig 1 Drift of 1 mω resistance Fig Drift of 100 Ω resistance 3..3 Effect of current This effect is sensible for 1 mω resistance depending on conditions of measurement (air, oil) (Fig 3). 1,000085 Resistance value (imilliohms) 1,00008 1,000075 1,00007 1,000065 y = 3E-08x + 9E-08x + 1,0001 y =,83E-10x + 1,95E-07x + 1,00E+00 air oil Poly. (air) Poly. (oil) 1,00006 0 5 10 15 0 5 Current ( A) Fig 3 Effect of current (air, oil bath) for 1 mω resistance Final report Nov 0 th, 014 Page 5 of 34

3..4 Other characteristics The influence of the current is lower than - 0, µω/ω for current increasing from 3 ma to 10 ma for 100 Ω resistance. 4 DESCRIPTION OF THE INTERLABORATORY COMPARISON AND ORGANIZATION 4.1 ORGANIZATION OF THE INTERLABORATORY COMPARISON The comparison was organized and controlled by the pilot laboratory. The comparison started at LNE, where the three resistors were calibrated and characterized in function of temperature. The standards were sent to KIM-LIPI where they were also calibrated. The standards were then returned to LNE. Finally the standards were re-calibrated by LNE and the results from both laboratories were compared. 4. COORDINATOR AND PARTICIPANTS OF THE COMPARISON Coordinator: Isabelle Blanc, isabelle.blanc.@lne.fr Laboratoire national de métrologie et d essais, LNE, France, Participants: Pilot laboratory: Participant: Laboratoire national de métrologie et d essais, LNE, ZA de Trappes-Élancourt, 9, avenue Roger Hennequin, 78197 TRAPPES Cedex, France Pierre-Jean Janin, pierre-jean.janin@lne.fr KIM-LIPI: Pusat Penelitian Kalibrasi, Instrumentasi, dan Metrologi Lembaga Ilmu Pengetahuan Indonesia (Puslit KIM-LIPI) Kompleks PUSPIPTEK Gedung 40 Tangerang Selatan, Banten Indonesia Lukluk Khairiyati, luluk@kim.lipi.go.id Agah faisal, agahfaisal@yahoo.co.id Muhammad Azzumar, muhammad.azzumar@lipi.go.id 4.3 TIME SCHEDULE The circulation was scheduled between May 014 and September 014. Preliminary measurements were performed at LNE in November 013 for the qualification of the standards. The original measurements were taken from calibrations performed in May 014. The resistance was sent to KIM-LIPI, Indonesia, on June 5 th. The resistance was carried back to LNE on September 17 th and the final measurements were performed at LNE from October 8 th to 16 th, 014. The standards were measured at KIM-LIPI from August 5 th and September 9 th, 014. The preliminary report from KIM-LIPI was received by LNE on September 0 th, 014. The draft report of the comparison was sent on October 30 th 014 and the final on November 014. Final report Nov 0 th, 014 Page 6 of 34

4.4 INSTRUCTIONS A copy of the complete measurement instructions sent to the participating laboratory is given in Appendix A. The measurements were performed under the following conditions. Resistance 1 mω: Four terminals ; DC current: 1 A, 10 A and 0 A ; Temperature of the environment (oil bath) : 3,0 C ± 0,1 C ; Measurement performed in oil. Resistance 100 Ω: Four terminals ; DC current: 5 ma ; Temperature of the environment (oil bath): 3,0 C ± 0,1 C ; Measurement performed in oil. Resistance 100 MΩ: Three terminals ; Test voltage: 100 V ; Temperature of the environment : 3 C ± C ; Relative humidity of air: between 30 % and 70 %. 5 METHOD OF MEASUREMENTS 5.1 LNE METHOD 5.1.1 Method 1 mω and the 100 Ω resistances: Measurements were performed by means of a zero flux current comparator MI6010B (Fig 4). The comparator is used alone for ratios between 1 and 10 and coupled with a range extender associated with a current source for ratios lower than 1. Fig 4: Diagram of the zero flux current comparator MI6010B. Final report Nov 0 th, 014 Page 7 of 34

The principle of the comparator is as following: a zero flux is detected when currents I p and I s satisfy to the condition I I s p N N p =, s where: I s is the current flowing through the standard resistor R e ; I p, the current flowing through the resistor R x to calibrate ; N s, the number of turns of the winding submitted to I s ; N p, the number of turns of the winding submitted to I p. The comparator automatically adjusts N p so that voltages developed across both resistors are equal. R e, R x, I s and I p are then linked by the relation N p R x. Re = K. R N = where K is the ratio of the comparator. s e R. I = R. I. The value of R x is finally given by Taking into account the effect of the temperature, this relation can be written as: R R x x. R1.1 ( + R 1) ( +. T + ) = K. α T (1) for the 1 mω resistor ; 1 1 K' 001. = K α 10 R1.1 R 1 R.. T 1 10 10 e s α () for the 100 Ω resistor. where: K 1 is the exact value of the ratio 1 of the comparator ; K 10, the exact value of the ratio 10 of the comparator ; K 001, the exact value of the ratio 1/1000 of the comparator ; α R1, the temperature coefficient of the 1 Ω standard resistor ; α R10, the temperature coefficient of the 10 Ω standard resistor ; T 1, the difference between the temperature at which the 1 Ω standard resistor has been calibrated and the temperature at which it was then used to calibrate the 10 Ω resistors ; T 10, the difference between the temperature at which the 10 Ω standard resistor has been calibrated and the temperature at which it was then used to calibrate the 100 Ω resistor. The 1 Ω standard resistor (needed for the calibration of the calibration of the 1 mω travelling standard and the 10 Ω standard resistor) was directly calibrated against the quantum Hall effect. The 10 Ω standard resistor (needed for the calibration of the 100 Ω travelling standard) was calibrated against the 1 Ω standard resistor using the MI6010B comparator. 100 MΩ resistance: Measurements were performed by means of a controlled Wheatstone bridge (Fig 5). x p Fig 5: Diagram of the controlled Wheatstone bridge. Final report Nov 0 th, 014 Page 8 of 34

Measurement conditions were: U = 100 V, P = 10 MΩ, Q = 100 kω and R = 1 MΩ. P When the bridge is balanced ( d = 0 ) the value of R x is given by R x =. R. Q In practice the bridge is considered balanced not when d = 0 but when dm = 0 where dm is the R. ( 1+ δ ) voltage measured by a null detector. In this case the expression of Rx is R x = (3) Q Q dm 1 +. P p U R 1 1 1 with δ =. + + g RxN ρ R where: g is the open loop gain of the operational amplifier ; ρ, its input impedance ; R xn, the nominal value of R x. 5.1. Reference standards and source of traceability 1 mω and the 100 Ω resistances: The 1 Ω standard resistor (needed for the calibration of the calibration of the 1 mω travelling standard and the 10 Ω standard resistor) was directly calibrated against the quantum Hall effect. The 10 Ω standard resistor (needed for the calibration of the 100 Ω travelling standard) was calibrated against the 1 Ω standard resistor using the MI6010B comparator. 100 MΩ resistance: The P, Q and R standard resistors used in the controlled Wheatstone bridge were calibrated by means of a MI6000A bridge associated with a 10 kω standard resistor directly calibrated against quantum Hall effect. Final report Nov 0 th, 014 Page 9 of 34

5. KIM-LIPI 5..1 Method 1 mω resistance The ILC traveling standard was measured using KIM- LIPI's standard calibration system for low value resistance. The standard calibration system consists of a DCC Bridge Guildline 6675A, a range extender Guildline 663, a DC power supply up to 0 A, and a standard resistor of 1 Ω from Leeds & Northrup Company by the model of 410-B (Fig 6). The standard resistor was immersed in a oil bath and controlled at the temperature of (3,0 ± 0,1) C. In order to measure the working current that flows to the UUT during a measurement, a current shunt was put in series to the UUT and the voltage drop across the current shunt was observed by a digital voltmeter. The measurement was performed by comparing the UUT and the Standard connected to the R X and R S arms of the DCC bridge respectively. The current supply to the UUT was fed by the extender at range of X1000. The bridge indicated the ratio between them. Fig 6: The schematic diagram of standard calibration system in KIM-LIPI (1 mω) 100 Ω resistance The ILC traveling standard was measured using KIM- LIPI's standard calibration system for intermediate value resistance. The standard calibration system consists of a DCC Bridge Guildline 6675A, and a standard resistor of 100 Ω from Leeds & Northrup Company by the model of 4030-B (Fig 7). Both standard and UUT resistor were immersed in an oil bath and controlled at the temperature of (3,0 ± 0,1) C. The measurement was performed by comparing the UUT and the Standard connected to the RX and RS arms of the DCC bridge respectively. The current supply to the UUT was 5 ma. The bridge indicated the ratio between them. Fig 7: The schematic diagram of standard calibration system in KIM-LIPI (100 Ω) 100 MΩ resistance The ILC traveling standard was measured using KIM- LIPI's standard calibration system for high value resistance. The standard calibration system consists of a DCC Bridge Guildline 6675A, and a standard resistor of 10 MΩ from Fluke Company by the model of 74A (Fig 8). Both standard and UUT resistor were at the room temperature of (3 ± ) C. The measurement was performed by comparing the UUT and the Standard connected to the RX and RS arms of the DCC bridge respectively. The voltage output from DCC bridge were observed prior the measurement and confirmed at 100 V output. The bridge indicated the ratio between them. Fig 8: The schematic diagram of standard calibration system in KIM-LIPI (100 MΩ) Final report Nov 0 th, 014 Page 10 of 34

5.. Reference standards and source of traceability The traceability is ensured through a 1 Ω resistance value from which the other values of resistances are derived. This resistance value is obtained from a group of seven 1 Ω resistors maintained by direct comparisons between each other. Traceability of each resistor against QHR system was established on 007. 6 CHARACTERIZATION OF THE REFERENCE VALUE 6.1 DETERMINATION OF THE COMPARISON REFERENCE VALUE The comparison reference value, R ref, has been determined as the linear interpolated value between the first and final measurements performed at LNE. The resistance values were given at (3,0 ± 0,) C. The temperature coefficients are only used for the determination of the uncertainty associated to the reference value. 6. REFERENCE VALUE OF THE COMPARISON As a slight drift is observed for the 1 mω and the 100 MΩ travelling standards, an interpolated value between the first and the final measurements performed at LNE taking into account the dates of measurement has been chosen as the reference value for the comparison. Expressions of the reference value R ref and its uncertainty u[r ref )] are: ( t ) R( t1 ). ( t t ) R ( t ) R R ref = + t 1 u[ R ref ] = ( ) ( ) t t t1.{ t t. u R t1 + t t1. u R t 1 [ ] ( ) [ ( )] ( t t)(. t t ). r[ R( t ), R( t )]. u[ R( t )]. u[ R( t )] + ( t t ). u ( } 1/ +. T 1 1 1 1 ) where: t 1 is the date of the first measurement at LNE ; t, the date of the final measurement at LNE ; t, the date of measurement at KIM-LIPI ; u[r(t 1 ),R(t )], the correlation coefficient between R(t 1 ) and R(t ) taken equal to 1 ; u( T ) = Rref.[ α. T + β.( T ) ] is an additional uncertainty component linked with the uncertainty of the temperature T, α and β being the temperature coefficients of the resistor. For the 100 Ω resistor, no significant drift is observed. The reference value for all measurement is given in Tab 3. 1 mω - 1 A 1 mω - 10 A 1 mω - 0 A 100 Ω - 5 ma 100 MΩ - 100 V R ref 1,000066 1,0000644 1,0000666 100,00161 100,0058 U[R ref ] (k = ) 0,000003 0,000003 0,000003 0,00004 0,00 unit mω mω mω Ω MΩ Tab 3: Reference value of the comparison Final report Nov 0 th, 014 Page 11 of 34

7 MEASUREMENT RESULTS Only one measurement was performed by LNE on May 014 for the calibration of 1 mω. However as the effect of current was preliminary determined, the measurement results were deduced from the determinations. Participants were asked to provide estimates of standard uncertainties, the effective degrees of freedom and the combined standard uncertainty. The uncertainty budgets provided by the participants can be found in Appendix B. The measurement results and their associated expanded uncertainties can be found in Tab 4 to 8. Each table is followed by a graphical illustration of the reported results and the corresponding reference values (Fig 9 to 13). 7.1 RESISTANCE 1 mω DC resistance value at 1 A Lab. Date Temperature ( C) T ( C) R (mω) U (mω) LNE 13/05/014,98 0,05 1,0000617 0,0000017 KIM-LIPI 05/08/014 3, 0 0,1 1,0000689 0,000016 LNE 13/10/014 3,0 0,05 1,0000633 0,0000017 Tab 4: Results for 1 mω resistor measured at 1 A 1.0000900 1.0000850 1 mωat 1 A 1.0000800 1.0000750 1.0000700 1.0000650 1.0000600 DC resistance value at 1 A 1.0000550 1.0000500 1/04/014 10/06/014 30/07/014 18/09/014 07/11/014 Fig 9: Results for 1 mω resistor measured at 1 A Final report Nov 0 th, 014 Page 1 of 34

DC resistance value at 10 A Lab. Date Temperature ( C) T ( C) R (mω) U (mω) LNE 13/05/014 3,0 0, 1,0000635 0,0000017 KIM-LIPI 05/08/014 3, 1 0,1 1,0000638 0,000017 LNE 13/10/014 3,1 0, 1,000065 0,0000017 Tab 5: Results for 1 mω resistor measured at 10 A 1.0000850 1.0000800 1 mωat 10 A 1.0000750 1.0000700 1.0000650 1.0000600 1.0000550 DC resistance value at 10 A 1.0000500 1.0000450 1/04/014 10/06/014 30/07/014 18/09/014 07/11/014 Fig 10: Results for 1 mω resistor measured at 10 A DC resistance value at 0 A Lab. Date Temperature ( C) T ( C) R (mω) U (mω) LNE 13/05/014 3,0 0, 1,0000655 0,0000017 KIM-LIPI 05/08/014 3, 1 0,1 1,0000660 0,000017 LNE 13/10/014 3,58 0, 1,0000674 0,0000017 Tab 6: Results for 1 mω resistor measured at 0 A Final report Nov 0 th, 014 Page 13 of 34

1.0000850 1.0000800 1 mωat 0 A 1.0000750 1.0000700 1.0000650 1.0000600 1.0000550 DC resistance value at 0 A 1.0000500 1.0000450 1/04/014 10/06/014 30/07/014 18/09/014 07/11/014 Fig 11: Results for 1 mω resistor measured at 0 A 7. RESISTANCE 100 Ω Lab. Date Temperature T ( C) I(mA) R (Ω) U (Ω) LNE 7/11/013,99 0,05 <10 100,001613 0,000035 LNE 13/05/014 3,01 0,05 <10 100,001605 0,000035 KIM-LIPI 5/08/014 3, 0 0,1 5 100,00167 0,0006 LNE 10/10/014 3,03 0,05 5 100,001604 0,000035 Tab 7: Results for 100 Ω resistor 100.00 100.0019 100 Ω 100.0018 100.0017 100.0016 100.0015 DC resistance value 100.0014 100.0013 03/10/013 0/03/014 30/07/014 7/1/014 Fig 1: Results for 100 Ω resistor Final report Nov 0 th, 014 Page 14 of 34

7.3 RESISTANCE 100 MΩ Lab. Date Temperature T ( C) Relative Humidity (%) Voltage (V) R (MΩ) U (MΩ) LNE 7/11/013 3,0 0, 45 100 100,0060 0,000 KIM-LIPI 09/09/014 3,1 0,1 51 100 99,9876 0,0034 LNE 16/10/014 3 0, 45 100 100,0058 0,000 Tab 8: Results for 100 MΩ resistor 100.0100 100.0050 100 MΩ 100.0000 99.9950 99.9900 DC resistance value 99.9850 99.9800 03/10/013 0/03/014 30/07/014 7/1/014 Fig 13: Results for 100 MΩ resistor 8 DISCUSSION OF THE RESULTS The results presented by KIM-LIPI show a good agreement with the pilot laboratory for 1 mω and 100 Ω. Although the measurements used by the participants are quite similar, there is a major variation in the reported uncertainties from each participant. A contrario, the results for 100 MΩ are not consistent within the associated uncertainties. A difference of 18 kω is observed for an uncertainty of 3,4 kω. Final report Nov 0 th, 014 Page 15 of 34

9 DEGREES OF EQUIVALENCE OF KIM LIPI 9.1 DEGREES OF EQUIVALENCE (DOE) BETWEEN LNE AND KIM-LIPI The values and the uncertainties reported by both laboratories are used in the calculation of the DoE. The degree of equivalence (DoE) between LNE and KIM-LIPI is summarized as follows: with an expanded uncertainty D = LIPI R KIM R ref [ R ] U [ R ] U [D] + = U KIM LIPI ref The computed values for the degree of equivalence between LNE and KIM-LIPI are given in table 7 in absolute value and in table 8 in relative value. 1 mω - 1 A 1 mω - 10 A 1 mω - 0 A 100 Ω - 5 ma 100 MΩ - 100 V D 0,000006-0,000001-0,000001 0,00006-0,0183 U[D] 0,000016 0,000017 0,000017 0,0006 0,0040 unit mω mω mω Ω MΩ Tab 9: Degrees of equivalence between KIM-LIPI and LNE associated to the expanded uncertainties (k = ) in absolute value. 1 mω - 1 A 1 mω - 10 A 1 mω - 0 A 100 Ω - 5 ma 100 MΩ - 100 V D 6-1 -1 0,6-183 U[D] 16 17 17,6 40 unit µω/ω µω/ω µω/ω µω/ω µω/ω Tab 10: Degrees of equivalence between KIM-LIPI and LNE associated to the expanded uncertainties (k = ) in relative value (µω/ω). 9. LINK TO THE CCEM KEY COMPARISON The results of the comparison can be linked to the CCEM from through the LNE differences from the CCEM-K10 (100 Ω) and CCEM-K (100 MΩ) comparison reference values. There s no direct link for results of calibration of 1 mω. Considering the results of the comparison, the link is only established for the 100 Ω resistance. The reported DoE of LNE with respect to the CCEM-K10 reference value are as follows [1] []: d LNE = 13,17 nω/ω, U(d LNE ) = 19,5 nω/ω (k=) The DoE of KIM-LIPI with respect to the BIPM KCRV is given by the following equation: d KIM-LIPI = D - d LNE Final report Nov 0 th, 014 Page 16 of 34

The uncertainty is given by: u (d KIM-LIPI ) = u (D) + u (d LNE ) + u (d s ) where u(d s ) is an additional uncertainty component associated to an eventual drift of the LNE standard in the time interval between the CCEM and the KIM-LIPI comparison. This component has been considered as negligible. Therefore the d KIM-LIPI value and the expanded uncertainty (k = ) are as follows: d KIM-LIPI = 0,6 µω/ω, U(d KIM-LIPI ) =,6 µω/ω 10 CONCLUSION The degree of equivalence of KIM-LIPI with KCRV for 100 Ω is established and it is consistent with the associated uncertainty. For 1 mω, there s no direct link to CCEM comparisons. The agreement between KIM-LIPI and LNE is good. Nevertheless a large difference is observed between the two laboratories for a current of 1 A, which remains however consistent with the given uncertainties (6,3 µω/ω for 16 µω/ω). The results for 100 MΩ are not consistent within the associated uncertainties. KIM-LIPI has to identify the causes of this discrepancy. 11 APPENDICES Appendix A Instructions Appendix B Uncertainty budget References [1] B. Schumacher, Final Report, CCEM-K10 Key Comparison of Resistance Standards at 100 Ω. [] B. Schumacher, Final Report, EUROMET.EM-K10 Key Comparison of Resistance Standards at 100 Ω. www.bipm.org * * * * * * * Final report Nov 0 th, 014 Page 17 of 34

Appendix A - Instructions Le 9/01/013 APPENDIX A - Instructions BILATERAL COMPARAISON of DC Resistance 1 mω 1. INTRODUCTION TECHNICAL PROTOCOL The comparison is organised within the EU-Indonesia Trade Support Programme II, Sub-project Number AWP--0-5, Improvement of traceability of Metrology and Calibration measurements of Puslit KIM. Two National Metrology Institutes take part in this comparison: LNE (France) and KIM-LIPI (Indonesia). LNE is acting as the pilot laboratory and in this function is responsible for providing the travelling standard, the evaluation of the measurement results and the final report. The comparison will be accomplished in accordance with the EURAMET Guidelines on Conducting Comparisons and CCEM Guidelines for Planning, Organising, Conducting and Reporting Key, Supplementary and Pilot Comparisons.. TRAVELLING STANDARDS.1. The travelling standard is a resistance (YEW, type 79) having the nominal value of 1 mω... Specifications Nominal value of the resistance: Dimensions of the case: Mass Approx: 1mΩ 40 mm x 30 mm x 0 mm 3 kg. 3. QUANTITIES TO BE MEASURED R: resistance of the standard (four terminals). I: DC current through the resistor. T ext : the temperature ( C) of the environment where the standard is measured. 4. MEASUREMENT INSTRUCTIONS The measurements should be performed under the following conditions: DC current: 1 A, 10 A and 0A. Temperature of the environment: 3 C ± C. Relative humidity of air: between 30 % and 70 %. 5. REPORTING OF RESULTS A report should be sent to the pilot laboratory within one month after the measurements are completed. The report should include: Description of the measurement method. The reference standard. Final report Nov 0 th, 014 Page 18 of 34

Appendix A - Instructions The traceability to the SI. The results of the quantities to be measured (list of section 3). The associated standard uncertainties, the effective degrees of freedom and the expanded uncertainties. The measurement of the DC current and the temperature of the environment must also be recorded and reported. 6. UNCERTAINTY OF MEASUREMENT The uncertainty must be calculated following the ISO Guide to the expression of uncertainty in measurement (GUM) and the complete uncertainty budget must be reported. 7. TRANSPORTATION The travelling standard must be transported in the original case and protected from mechanical loads, vibration etc. for transport by plane. The travel box contains the following items: Resistance standard. Operating instructions of the travelling standard (this document). 8. CONTACT Pilot Laboratory: Contact: Laboratoire national de métrologie et d essais (LNE) ZA de Trappes-Élancourt 9, avenue Roger Hennequin 78197 TRAPPES Cedex France Mrs. BLANC Isabelle Tél.: +33(0)1 30 69 1 08 Fax: +33(0)1 30 16 4 5 Mail: isabelle.blanc.@lne.fr KIM LIPI: Contacts: Pusat Penelitian Kalibrasi, Instrumentasi, dan Metrologi Lembaga Ilmu Pengetahuan Indonesia (Puslit KIM-LIPI) Kompleks PUSPIPTEK Gedung 40 Tangerang Selatan, Banten Indonesia Mr. Agah Faisal Tel : (+61) 756056 Fax : (+61) 7560064 Email : agahfaisal@yahoo.co.id Mrs. Lukluk Khairiyati Tel : (+61) 756056 Fax : (+61) 7560064 Email : luluk@kim.lipi.go.id ************************* Final report Nov 0 th, 014 Page 19 of 34

Appendix A - Instructions Le 9/01/013 BILATERAL COMPARAISON of DC Resistance 100 Ω 1. INTRODUCTION TECHNICAL PROTOCOL The comparison is organised within the EU-Indonesia Trade Support Programme II, Sub-project Number AWP--0-5, Improvement of traceability of Metrology and Calibration measurements of Puslit KIM. The comparison is linked to the corresponding CCEM comparison CCEM-K10. Two National Metrology Institutes take part in this comparison: LNE (France) and KIM-LIPI (Indonesia). LNE is acting as the pilot laboratory and in this function is responsible for providing the travelling standard, the evaluation of the measurement results and the final report. The comparison will be accomplished in accordance with the EURAMET Guidelines on Conducting Comparisons and CCEM Guidelines for Planning, Organising, Conducting and Reporting Key, Supplementary and Pilot Comparisons.. TRAVELLING STANDARDS.1. The travelling standard is a resistance (Guildline 9330) having the nominal value of 100 Ω... Specifications Nominal value of the resistance: Dimensions of the case: Total mass Approx. 100 Ω 40 mm x 30 mm x 0 mm 5 kg. 3. QUANTITIES TO BE MEASURED R: resistance of the standard (four terminals). I: DC current through the resistor. T ext : the temperature ( C) of the environment where the standard is measured (oil bath). 4. MEASUREMENT INSTRUCTIONS The measurements should be performed under the following conditions: DC current: 5 ma. Temperature of the environment (oil bath): 3 C ± 0.1 C. Relative humidity of air: between 30 % and 70 %. 5. REPORTING OF RESULTS A report should be sent to the pilot laboratory within one month after the measurements are completed. The report should include: Description of the measurement method. Final report Nov 0 th, 014 Page 0 of 34

Appendix A - Instructions The reference standard. The traceability to the SI. The results of the quantities to be measured (list of section 3). The associated standard uncertainties, the effective degrees of freedom and the expanded uncertainties. The measurement of the DC current and the temperature of the oil bath must also be recorded and reported. 6. UNCERTAINTY OF MEASUREMENT The uncertainty must be calculated following the ISO Guide to the expression of uncertainty in measurement (GUM) and the complete uncertainty budget must be reported. 7. TRANSPORTATION The travelling standard must be transported in the original case and protected from mechanical loads, vibration etc. for transport by plane. The travel box contains the following items: Resistance standard. Operating instructions of the travelling standard (this document). 8. CONTACT Pilot Laboratory : Laboratoire national de métrologie et d essais (LNE) ZA de Trappes-Élancourt 9, avenue Roger Hennequin 78197 TRAPPES Cedex France Contact : Mrs. BLANC Isabelle Tél.: +33(0)1 30 69 1 08 Fax: +33(0)1 30 16 4 5 Mail: isabelle.blanc.@lne.fr KIM LIPI : Contacts: Pusat Penelitian Kalibrasi, Instrumentasi, dan Metrologi Lembaga Ilmu Pengetahuan Indonesia (Puslit KIM-LIPI) Kompleks PUSPIPTEK Gedung 40 Tangerang Selatan, Banten Indonesia Mr. Agah Faisal Tel : (+61) 756056 Fax : (+61) 7560064 Email : agahfaisal@yahoo.co.id Mrs. Lukluk Khairiyati Tel : (+61) 756056 Fax : (+61) 7560064 Email : luluk@kim.lipi.go.id ************************* Final report Nov 0 th, 014 Page 1 of 34

Appendix A - Instructions Le 8/01/013 BILATERAL COMPARAISON of DC Resistance 100 MΩ 1. INTRODUCTION TECHNICAL PROTOCOL The comparison is organised within the EU-Indonesia Trade Support Programme II, Sub-project Number AWP--0-5, Improvement of traceability of Metrology and Calibration measurements of Puslit KIM. The comparison is linked to the corresponding CCEM comparison CCEM-K. Two National Metrology Institutes take part in this comparison: LNE (France) and KIM-LIPI (Indonesia). LNE is acting as the pilot laboratory and in this function is responsible for providing the travelling standard, the evaluation of the measurement results and the final report. The comparison will be accomplished in accordance with the EURAMET Guidelines on Conducting Comparisons and CCEM Guidelines for Planning, Organising, Conducting and Reporting Key, Supplementary and Pilot Comparisons.. TRAVELLING STANDARDS.1. The travelling standard is a resistance (Guildline 9330) having the nominal value of 100 MΩ... Specifications Nominal value of the resistance: Dimensions of the case: Total mass Approx.: 100 MΩ 40 mm x 30 mm x 0 mm 3 kg. 3. QUANTITIES TO BE MEASURED R: resistance of the standard (three terminals). V: test voltage. T ext : the temperature ( C) of the environment where the standard is measured. RH ext: relative humidity of the environment. 4. MEASUREMENT INSTRUCTIONS The measurements should be performed under the following conditions: Test voltage: V test 100 V, preferably 100 V. Temperature of the environment: 3 C ± C. Relative humidity of air: between 30 % and 70 %. 5. REPORTING OF RESULTS A report should be sent to the pilot laboratory within one month after the measurements are completed. The report should include: Description of the measurement method. Final report Nov 0 th, 014 Page of 34

Appendix A - Instructions The reference standard. The traceability to the SI. The results of the quantities to be measured (list of section 3). The associated standard uncertainties, the effective degrees of freedom and the expanded uncertainties. The measurement of the DC current and the temperature of the oil bath must also be recorded and reported. 6. UNCERTAINTY OF MEASUREMENT The uncertainty must be calculated following the ISO Guide to the expression of uncertainty in measurement (GUM) and the complete uncertainty budget must be reported. 7. TRANSPORTATION The travelling standard must be transported in the original case and protected from mechanical loads, vibration etc. for transport by plane. The travel box contains the following items: Resistance standard. Operating instructions of the travelling standard (this document). 8. CONTACT Pilot Laboratory: Laboratoire national de métrologie et d essais (LNE) ZA de Trappes-Élancourt 9, avenue Roger Hennequin 78197 TRAPPES Cedex France Contact: Mrs. BLANC Isabelle Tél.: +33(0)1 30 69 1 08 Fax: +33(0)1 30 16 4 5 Mail: isabelle.blanc.@lne.fr KIM LIPI: Contacts: Pusat Penelitian Kalibrasi, Instrumentasi, dan Metrologi Lembaga Ilmu Pengetahuan Indonesia (Puslit KIM-LIPI) Kompleks PUSPIPTEK Gedung 40 Tangerang Selatan, Banten Indonesia Mr. Agah Faisal Tel : (+61) 756056 Fax : (+61) 7560064 Email : agahfaisal@yahoo.co.id Mrs. Lukluk Khairiyati Tel : (+61) 756056 Fax : (+61) 7560064 Email : luluk@kim.lipi.go.id ************************* Final report Nov 0 th, 014 Page 3 of 34

Appendix B Uncertainty budget APPENDIX B - UNCERTAINTY BUDGET LNE uncertainty budget 1 mω and 100 Ω resistances For measurements performed with the MI6010B comparator (1 mω and 100 Ω) the uncertainty budget is as follows. From equations (1) and () it can be deduced: u u 6 6 ( R ) =. u ( K ) + u ( K ' ) + 10. u ( R ) + ( 0,001. T ). u ( α ) + ( 0,001. α ). u ( T ) x ( R ) x = 10 1 0,001 1 1 R R 1 400. u + ( K 10 4 ) + 10. u ( R ) + ( 100. T ). u ( α ) + ( 100. α ) ( 100. T ). u ( α ) + ( 100. α ). u ( T ) 10 Following uncertainty components have been identified: R 10 1 R 10 1 10 R 1 1 for the 1 mω resistor and R 1. u ( T ) for the 100 Ω resistor. A1: component linked to the stability (including noise) and the resolution of the bridge alone. It is estimated to A1 = 1.10-8.K for K 1. A: component linked to the stability (including noise) and the resolution of the bridge associated with the range extender needed for ratios lower than 1. It is estimated to A = 5.10-7.K for k = 0,001. B1: calibration uncertainty of the 1 Ω standard resistor against the quantum Hall effect. It is equal to B1 = 5.10-8.R (k = 1). B: uncertainty of the evaluation of the ratio K = 1 of the bridge estimated to B = 1,3.10-8.K. B3: uncertainty of the evaluation of the ratio K = 10 of the bridge estimated to B3 = 6,9.10-8.K. B4 : uncertainty of the evaluation of the ratio K = 0.001 of the bridge estimated to B4 = 5,7.10-7.K. B5: uncertainty component linked to the drift of the 1 Ω standard resistor estimated to B5 =,9.10-8.R. B6: uncertainty component linked to the difference between the temperature at which the 1 Ω standard resistor has been calibrated and the temperature at which it served as reference for subsequent calibrations. It has been estimated to B6 = 0,008 C. B7: uncertainty component linked to the difference between the temperature at which the 10 Ω standard resistor has been calibrated and the temperature at which it served as reference for the calibration of the 100 Ω travelling standard. It has been estimated to B7 = 0,003 C. B8: uncertainty component linked with the influence of the current generated by the current source associated with the range extender on the ratio K = 0.001 of the bridge. It has been estimated to B8 =,6.10-7.K. Taking into account all these components, the two equations above lead to: u 6 6 ( R ) = 10.B + (A + B4 + B8 ) + 10.(B1 + B5 ) + ( 0,001. α ).B x R 6 1 for the 1 mω resistor and 1 1 u 4 ( R ) = 400.(A1 + B3 ) + 10.(B1 + B5 ) + ( 100. α ).B6 + ( 100. α ).B x R R 7 1 10 for the 100 Ω resistor. Final report Nov 0 th, 014 Page 4 of 34

Appendix B Uncertainty budget Detailed values of the uncertainty budget for the 1 mω and the 100 Ω resistors are given in tables B1 and B. Quantity Probability Uncertainty Standard distribution Sensitivity Degree of contribution uncertainty /method of coefficient freedom ( nω) evaluation X i u(x i ) (A,B) c i u(r i ) υ i stability including noise and resolution of the brige associated with the range extender needed for ratios lower than 1 0,5 10-9 type A 1 Ω 0,50 5 calibration uncertainty of the 1 Ω standard resistor against the quantum Hall effect 50 nω norm/type B 0,001 0,05 inf evaluation of the ratio K = 1 of the bridge 13 10-9 norm/type B 0,001 Ω 0,01 inf evaluation of the ratio K = 0,001 of the bridge 0,57 10-9 norm/type B 1 Ω 0,57 inf drift of the 1 Ω standard resistor 9 nω rect/type B 0,001 0,03 inf uncertainty component linked to the difference between the temperature at which the 1 Ω standard resistor has been calibrated and the temperature at which it served as reference for subsequent calibration 0,008 C U/type B 4,00E-01 νω/ C 0,00 inf influence of the current generated by the current source associated with the range extender on the ratio K = 0,001 of the bridge 0,6 10-9 rect/type B 1 Ω 0,6 inf Combined standard uncertainty 0,8 Effective degrees of freedom inf Expanded uncertainty (k=) 1,7 nω 1,7 µω/ω Table B1: Uncertainty budget for the 1 mω resistor. Probability Uncertainty Standard Degree of Quantity distribution Sensitivity contribution uncertainty /method of coefficient freedom (µω) evaluation X i u(x i ) (A,B) c i u(r i ) υ i stability including noise and resolution of the brige 0,10 10-6 type A 0 Ω,0 5 calibration uncertainty of the 1 Ω standard resistor against the quantum Hall effect 0,05 µω norm/type B 100 5,0 inf evaluation of the ratio K = 10 of the bridge 0,69 10-6 norm/type B 0 Ω 13,8 inf drift of the 1 Ω standard resistor 0,03 µω rect/type B 100,9 inf uncertainty component linked to the difference between the temperature at which the 1 Ω standard resistor has been calibrated and the temperature at which it served as reference for subsequent calibration 0,008 C U/type B 40 µω/ C 0,3 inf uncertainty component linked to the difference between the temperature at which the 10 Ω standard resistor has been calibrated and the temperature at which it served as reference for the calibration of the 100 Ω travelling standard 0,003 C U/type B 160 µω/ C 0,48 inf Combined standard uncertainty 15,1 Effective degrees of freedom inf Expanded uncertainty (k=) 3 µω 0,3 µω/ω Table B: Uncertainty budget for the 100 Ω resistor. Final report Nov 0 th, 014 Page 5 of 34

Appendix B Uncertainty budget 100 MΩ resistance For measurements performed with the controlled Wheatstone bridge (100 MΩ) the uncertainty budget is as follows. From equation (3) it can be deduced: u(r X ) = P.R Q.u Rx. + Q.U ( δ) +.u ( P) +.u ( R) +.u ( Q) ( P + Q) ( P + ) R Q Q.dm.u ( dm) P Q P.R Q Detailed values of the uncertainty budget for the 100 MΩ resistor are given in table B3. Quantity Probability Uncertainty Standard Sensitivity Degree of distribution contribution ( uncertainty coefficient freedom /method of Ω) evaluation X i u(x i ) (A,B) c i u(r i ) υ i calibration uncertainty of P standard resistor in the Wheatstone bridge 5 Ω norm/type B 10 50 inf calibration uncertainty of R standard resistor in the Wheatstone bridge 1 Ω norm/type B 100 100 inf calibration uncertainty of Q standard resistor in the Wheatstone bridge 0,5 Ω norm/type B 1000 50 inf drift of P standard restistor 8 Ω rect/type B 10 80 inf drift of Q standard restistor 0,8 Ω rect/type B 100 80 inf drift of R standard restistor 0,08 Ω rect/type B 1000 80 inf influence of temperature on standard resistor P in the Wheatstone bridge 11 Ω U/type B 10 110 inf influence of temperature on standard resistor R in the Wheatstone bridge 0,06 Ω U/type B 100 6 inf influence of temperature on standard resistor Q in the Wheatstone bridge 0,006 Ω U/type B 1000 6 inf effect of the input impedance and the open loop gain of the amplifier 51 Ω rect/type B 1 51 inf noise and sensitivity of the bridge 1,5 µv rect/type B 100 Ω.µV -1 150 inf leakage resistance 0,0005 Ω rect/type B 100 0,05 inf Combined standard uncertainty 438 Effective degrees of freedom inf Expanded uncertainty (k=) 875 µω 8,8 µω/ω Table B3: Uncertainty budget for the 100 MΩ resistor. For the need of this comparison, this uncertainty will be enlarged to 0 µω/ω (k = ). Final report Nov 0 th, 014 Page 6 of 34

Appendix B Uncertainty budget KIM-LIPI uncertainty budget 1 mω resistance Model equation. The mathematical model for evaluating the measurement result is determined by following equation: Γ ( 1+ δba ) ( 1+ δbt ) ( 1+ δbr ) RS ( 1+ δrsd ) ( 1+ δrst ) ( 1+ δrsi ) RX = 1000 ( 1+ δrxt ) ( 1+ δrxi ) ( 1+ δrxr ) Where: R X : The unknown value of the 1 mω traveling standard (UUT) Γ : The indicated mean ratio of the UUT over the 1 Ω standard resistor δb A : The correction due to the accuracy of the DCC bridge δb T : The correction due to the temperature instability effect to the bridge during a measurement δb R : The correction due to the resolution of the bridge ratio indication R S : The known value of the 1 Ω standard resistor δr SD : The correction due to the drift of the 1 Ω standard resistor δr ST : The correction due to the temperature instability effect to the 1 Ω standard resistor δr SI : The correction due to the current dependency effect to the 1 Ω standard resistor δr XT : The correction due to the temperature instability effect to the UUT δr XI : The correction due to the current dependency effect to the UUT δr XR : The correction due to the rounding the reported value of the UUT To estimate the mean ratio value, the measurement was taken 10 times. Final report Nov 0 th, 014 Page 7 of 34

Appendix B Uncertainty budget at 1 A UNCERTAINTY BUDGET (1 mω) Quantity Estimate Standard uncertainty Probability distribution /method of evaluation (A,B) Sensitivity coefficient Uncertainty contribution Degree of freedom X i x i u(x i ) c i u(r i ) υ i The mean of ratio indication 0,001000076 Ω/Ω 1,5E-10 Ω/Ω type A 0,99999830 Ω 1,5E-10 9 The accuracy of the bridge 0 6,9E-07 Ω/Ω rect/ type B 0,001000069 Ω 6,9E-10 1E+0 The temperature instability effect to the bridge 0 1,E-08 Ω/Ω rect/ type B 0,001000069 Ω 1,E-11 1E+0 The resolution of the bridge ratio indication 0,9E-08 Ω/Ω rect/ type B 0,001000069 Ω,9E-11 1E+0 The trueness 1 Ω standard resistor 0,9999983 Ω 4,0E-07 Ω norm/ type B 0,001000076 Ω/Ω 4,0E-10 1E+0 The drift of the 1 Ω standard resistor 0 1,0E-08 Ω/Ω norm/ type B 0,001000069 Ω 1,0E-11 1E+0 Temperature instability effect to the 1 Ω standard resistor The current dependency effect to the 1 Ω standard resistor 0 1,0E-07 Ω/Ω rect/ type B 0,001000069 Ω 1,0E-10 1E+0 0 3,5E-11 Ω/Ω rect/ type B 0,001000069 Ω 3,5E-14 1E+0 The temperature instability effect to the UUT 0 8,3E-06 Ω/Ω rect/ type B 0,001000069 Ω 8,3E-09 1E+0 The current dependency effect to the UUT 0 1,4E-07 Ω/Ω rect/ type B 0,001000069 Ω 1,4E-10 1E+0 Rounding the reported value of UUT 0,9E-08 Ω/Ω rect/ type B 0,001000069 Ω,9E-11 1E+0 R X 0,0010000689 Ω 1,000069 mω Combined standard uncertainty: 8,3E-09 Effective degrees of freedom: 8638048 Coverage factor at 95 % confidence level,0 0,0000000163 Ω Expanded uncertainty (95% coverage factor): 0,000016 mω 16 µω /Ω Final report Nov 0 th, 014 Page 8 of 34

Appendix B Uncertainty budget at 10 A UNCERTAINTY BUDGET (1 mω) Quantity Estimate Standard uncertainty Probability distribution /method of evaluation (A,B) Sensitivity coefficient Uncertainty contribution Degree of freedom X i x i u(x i ) c i u(r i ) υ i The mean of ratio indication 0,001000071 Ω/Ω 4,1E-11 Ω/Ω type A 0,99999830 Ω 4,1E-11 9 The accuracy of the bridge 0 6,9E-07 Ω/Ω rect/ type B 0,001000064 Ω 6,9E-10 1E+0 The temperature instability effect to the bridge 0 1,E-08 Ω/Ω rect/ type B 0,001000064 Ω 1,E-11 1E+0 The resolution of the bridge ratio indication 0,9E-08 Ω/Ω rect/ type B 0,001000064 Ω,9E-11 1E+0 The trueness 1 Ω standard resistor 0,9999983 Ω 4,0E-07 Ω norm/ type B 0,001000071 Ω/Ω 4,0E-10 1E+0 The drift of the 1 Ω standard resistor 0 1,0E-08 Ω/Ω norm/ type B 0,001000064 Ω 1,0E-11 1E+0 Temperature instability effect to the 1 Ω standard resistor The current dependency effect to the 1 Ω standard resistor 0 1,0E-07 Ω/Ω rect/ type B 0,001000064 Ω 1,0E-10 1E+0 0 3,5E-11 Ω/Ω rect/ type B 0,001000064 Ω 3,5E-14 1E+0 The temperature instability effect to the UUT 0 8,3E-06 Ω/Ω rect/ type B 0,001000064 Ω 8,3E-09 1E+0 The current dependency effect to the UUT 0 1,4E-07 Ω/Ω rect/ type B 0,001000064 Ω 1,4E-10 1E+0 Rounding the reported value of UUT 0,9E-08 Ω/Ω rect/ type B 0,001000064 Ω,9E-11 1E+0 0,0010000638 Ω 1,000064 mω Combined standard uncertainty: 8,3E-09 Effective degrees of freedom: 15594880031 Coverage factor at 95 % confidence level,0 0,0000000166 Ω Expanded uncertainty (95% coverage factor): 0,000017 mω 17 µω /Ω Final report Nov 0 th, 014 Page 9 of 34

Appendix B Uncertainty budget UNCERTAINTY BUDGET (1 mω) at 0 A Quantity Estimate Standard uncertainty Probability distribution /method of evaluation (A,B) Sensitivity coefficient Uncertainty contribution Degree of freedom X i x i u(x i ) c i u(r i ) υ i The mean of ratio indication 0,001000073 Ω/Ω 1,1E-11 Ω/Ω type A 0,99999830 Ω 1,1E-11 9 The accuracy of the bridge 0 6,9E-07 Ω/Ω rect/ type B 0,001000066 Ω 6,9E-10 1E+0 The temperature instability effect to the bridge 0 1,E-08 Ω/Ω rect/ type B 0,001000066 Ω 1,E-11 1E+0 The resolution of the bridge ratio indication 0,9E-08 Ω/Ω rect/ type B 0,001000066 Ω,9E-11 1E+0 The trueness 1 Ω standard resistor 0,9999983 Ω 4,0E-07 Ω norm/ type B 0,001000073 Ω/Ω 4,0E-10 1E+0 The drift of the 1 Ω standard resistor 0 1,0E-08 Ω/Ω norm/ type B 0,001000066 Ω 1,0E-11 1E+0 Temperature instability effect to the 1 Ω standard resistor The current dependency effect to the 1 Ω standard resistor 0 1,0E-07 Ω/Ω rect/ type B 0,001000066 Ω 1,0E-10 1E+0 0 3,5E-11 Ω/Ω rect/ type B 0,001000066 Ω 3,5E-14 1E+0 The temperature instability effect to the UUT 0 8,3E-06 Ω/Ω rect/ type B 0,001000066 Ω 8,3E-09 1E+0 The current dependency effect to the UUT 0 1,4E-07 Ω/Ω rect/ type B 0,001000066 Ω 1,4E-10 1E+0 Rounding the reported value of UUT 0,9E-08 Ω/Ω rect/ type B 0,001000066 Ω,9E-11 1E+0 0,0010000660 Ω 1,000066 mω Combined standard uncertainty: 8,3E-09 Effective degrees of freedom: 30903360538 Coverage factor at 95 % confidence level,0 0,0000000166 Ω Expanded uncertainty (95% coverage factor): 0,000017 mω 17 µω /Ω Final report Nov 0 th, 014 Page 30 of 34

Appendix B Uncertainty budget 100 Ω resistance Model equation. The mathematical model for evaluating the measurement result is determined by following equation: Where: R X Γ = ( 1+ δba ) ( 1+ δbt ) ( 1+ δbr ) RS ( 1+ δrsd ) ( 1+ δrst ) ( 1+ δr ) ( 1+ δr ) XT R X : The unknown value of the 100 Ω traveling standard (UUT) Γ : The indicated mean ratio of the UUT over the 100 Ω standard resistor δb A : The correction due to the accuracy of the DCC bridge δb T : The correction due to the temperature instability effect to the bridge during a measurement δb R : The correction due to the resolution of the bridge ratio indication R S : The known value of the 100 Ω standard resistor δr SD : The correction due to the drift of the 100 Ω standard resistor δr ST : The correction due to the temperature instability effect to the 100 Ω standard resistor δr XT : The correction due to the temperature instability effect to the UUT δr XR : The correction due to the rounding the reported value of the UUT To estimate the mean ratio value, the measurement was taken 10 times. XR Final report Nov 0 th, 014 Page 31 of 34

Appendix B Uncertainty budget at 5 ma UNCERTAINTY BUDGET (100 Ω) Quantity Estimate Standard uncertainty Probability distribution /method of evaluation (A,B) Sensitivity coefficient Uncertainty contribution Degree of freedom X i x i u(x i ) c i u(r i ) υ i The mean of ratio indication 1,000031055 Ω/Ω 1,7E-09 Ω/Ω type A 99,99856054 Ω 1,7E-07 9 The accuracy of the bridge 0 5,8E-08 Ω/Ω rect/ type B 100,0016660 Ω 5,8E-06 1E+0 The temperature instability effect to the bridge 0 1,E-08 Ω/Ω rect/ type B 100,0016660 Ω 1,E-06 1E+0 The resolution of the bridge ratio indication 0,9E-09 Ω/Ω rect/ type B 100,0016660 Ω,9E-07 1E+0 The trueness 100 Ω standard resistor 99,99856054 Ω 1,3E-04 Ω norm/ type B 1,000031055 Ω/Ω 1,3E-04 1E+0 The drift of the 100 Ω standard resistor 0 1,0E-08 Ω/Ω norm/ type B 100,0016660 Ω 1,0E-06 1E+0 Temperature instability effect to the 100 Ω standard resistor 0 1,0E-07 Ω/Ω rect/ type B 100,0016660 Ω 1,0E-05 1E+0 The temperature instability effect to the UUT 0 1,E-07 Ω/Ω rect/ type B 100,0016660 Ω 1,E-05 1E+0 Rounding the reported value of UUT 0,9E-08 Ω/Ω rect/ type B 100,0016660 Ω,9E-06 1E+0 100,00167 Ω Combined standard uncertainty: 1,3E-04 Effective degrees of freedom: 33809184969 Coverage factor at 95 % confidence level,0 Expanded uncertainty (95% coverage factor): 0,0006 Ω,6 µω /Ω Final report Nov 0 th, 014 Page 3 of 34

Appendix B Uncertainty budget 100 MΩ resistance Model equation. The mathematical model for evaluating the measurement result is determined by following equation: Where: R X Γ = ( 1+ δba ) ( 1+ δbt ) ( 1+ δbr ) RS ( 1+ δrsd ) ( 1+ δrst ) ( 1+ δr ) ( 1+ δr ) XT R X : The unknown value of the 100 MΩ traveling standard (UUT) Γ : The indicated mean ratio of the UUT over the 10 MΩ standard resistor δb A : The correction due to the accuracy of the DCC bridge δb T : The correction due to the temperature instability effect to the bridge during a measurement δb R : The correction due to the resolution of the bridge ratio indication R S : The known value of the 10 MΩ standard resistor δr SD : The correction due to the drift of the 10 MΩ standard resistor δr ST : The correction due to the temperature instability effect to the 10 MΩ standard resistor δr XT : The correction due to the temperature instability effect to the UUT δr XR : The correction due to the rounding the reported value of the UUT To estimate the mean ratio value, the measurement was taken 5 times. XR Final report Nov 0 th, 014 Page 33 of 34