TF 202 / TF 202-Ex. Field mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

Similar documents
TF 212 / TF 212-Ex. Field mounted temperature transmitters, PROFIBUS PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels 10/11-8.

TF 212 / TF 212-Ex. Field mounted temperature transmitter, Profibus PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels. ABB Instrumentation

Field mounted Temperature Transmitter TF212/TF212-Ex

S95.3U01 / S95.3U11. Head mounted temperature transmitters, programmable, Pt 100 (RTD), thermocouples, electrical isolation

TH 202 / TH 202-Ex. Field mounted temperature transmitter, HART programmable, Pt 100 (RTD), thermocouples, electrical isolation. ABB Instrumentation

S95.3U02 / S95.3U12. Head mounted temperature transmitters, HART programmable, Pt 100 (RTD), thermocouples, electrical isolation

SINEAX VK 636 Programmable Temperature Transmitter with PROFIBUS-PA protocol

Exchangeable measuring insets SensyTemp TSA101

SINEAX VK 626 Programmable Temperature Transmitter for RTD and TC inputs, with HART protocol

ED 701 General Industry Pressure Transmitter

Installation guide 862 MIT / MIR

PHOENIX CONTACT - 04/2016. Features

Pressure transmitters for industrial applications MBS 32 and MBS 33

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

CALYS 120 IS. ATEX documenting multifunction calibrator with high accuracy 0.006%

Physikalisch-Technische Bundesanstalt

4.2. Ex-Ceiling light fittings AB 80 / AB 05 LED / AB 05 / AB 12 NAV 70. (Zone 1, 2, 21, 22)

DS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

BMXART0814 analog input module M340-8 inputs - temperature

SCTP20 Programmable 2-Wire Temperature Transmitter, Head Mount

Z7A. Load cells. Special features. Data sheet. Wiring code

BMXART0814 analog input module M340-8 inputs - temperature

Multi-function, economical instrument with 4 functions in the same casing. Accessibility and safety: large-dimension terminals Insulated circuits

CALYS 80P. Field pressure calibrator with high accuracy 0.01%

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27

A BB ME ASU R E ME NT & AN AL Y T ICS D AT A S H E ET. SensyTemp TSA101 Exchangeable measuring insets

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas

Pascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure

Page 1 of 16 Issue No. 0 of IECEx TUN X

DS 200 DS 200 DRUCK & TEMPERATUR LEITENBERGER GMBH. Electronic Pressure Switch. Stainless Steel Sensor. Electronic Pressure Switch

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.

Field IT 50T Series Transmitters

4.3. Ex-Pendant light fittings AB 50 / SPG 1N / AB 51 / EVI 200 / EVI 500 / EV35 LED. (Zone 1, 2, 21, 22)

The Ordering Code for various standard model Recorders with an AC supply and without any additional options are as follows:

E X - C O N T R O L U N I T S A N D C O N T R O L S T A T I O N S

HYGRASGARD KFF KFTF HYGRASGARD AFF AFTF HYGRASGARD AFF - LC AFTF - LC

T20WN. Data Sheet. Torque transducers. Special features. Installation example with bellows couplings. B en

Ultrasonic Gas Flow Meter

4.13. Ex-Floodlights of the series FMV LED / NSSFMV. (Zone 2, 22) service life and a high level of efficiency. NFMV floodlights for highpressure

PRODUCT CATALOGUE PREssURE switch

Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level

Impedance relay and protection assemblies

ANNEX to IECEx Certificate

2.12. Ex-Linear light fittings for fluorescent lamps. nllk W - 58 W (Zone 2, 21, 22)

Ex-Floodlights of the series FMV LED / NFMV / NSSFMV. Stainless steel NSSFMV floodlights for particularly. in harsh environments

I nllk 08018/18 I nllk I nllk 08036/36 I nllk I I nllk 08058/58 I

Level Sensor PanCake PR 6251 and Mounting Kit PR 6051

Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager.

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22)

Linear measuring technology

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

BMXART0814 analog input module M340-8 inputs - temperature

Single point load cells

AIR PREPARATION. ELECTRONICALLY CONTROLLED PRESSURE REGULATING VALVE (PROPORTIONAL PRESSURE REGULATING VALVE) SERIES control

Capacitance Level Measurement Electronic Inserts EC 37 Z, EC 47 Z

Pressure Measurement Single-range transmitters for general applications

TÜV NORD CERT GmbH Hanover Office Am TÜV Hanover Germany. Testing Laboratory Explosion Protected Equipment and Monitoring Devices

PROline promag 53 Division 1

Pressure Transmitter ED 701

Reflex-Radar BM 100 A

Technical specification FLUXUS F502TE

EX-EMERGENCY LIGHT FITTINGS

Ring-Torsion Load Cells RTB

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER

ATEX/IECEx RTD temperature probe

Model DS1200-AMT-Ex Intrinsically Safe 4-20mA ATEX Certified Dewpoint Hygrometer Ranges available between -120 C to +20 C (-166 F to +68 F) dewpoint

Temperature sensors SensyTemp TSP311, TSP321, TSP331

I Ex d/e Switch- and Control-Equipment I

Operating Instructions for Digital Manometer. Model: MAN-SD

Relative pressure transmitter type 520

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

ST3000 Series 900 Smart Transmitter Differential Pressure Transmitters

Permanently installed and non-invasive ultrasonic flowmeter for the measurement of thermal energy and volumetric flow rate

2.12. Ex-Linear light fittings for fluorescent lamps - max. ambient temperature + 60 C - nllk W - 58 W for Zone 2 and 22

HAL501...HAL506, HAL508 Hall Effect Sensor ICs MICRONAS INTERMETALL MICRONAS. Edition May 5, DS

DIFFERENTIAL PRESSURE (FLOW) TRANSMITTER

BTE5000 / PTE5000 / PTU5000 Series Precision differential pressure transmitters

Installation Equipment

Certificate No.: IECEx BVS , issue 3 Annex Page 1 of 9

5SJ4...-.HG Circuit Breakers to IEC and UL 489

Industrial Pressure Transmitter

Hydraulic Pressure NAH Applications. Features. New generation available - refer to

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

THM80X Series Feature Application. Temperature & Humidity / Flow Measuring Specialist

Industrial Resistance Thermometers according to DIN Model MWD

VersaFlow Ultrasonic clamp-on Flowmeter Specifications

D5.2 Type. Draw wire mechanics with incremental encoder. Measuring length max. 2 m. Compact and simple. Order code draw wire encoder

Ref: HLSR 16-PW; HLSR 32-PW; HLSR 40-PW-000; HLSR 50-PW-000,

FKC... 5 DIFFERENTIAL PRESSURE (FLOW) TRANSMITTER FEATURES SPECIFICATIONS. Functional specifications

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

AT9000 Advanced Transmitter Differential Pressure Transmitters

MODEL: R7K4FML3. Remote I/O R7K4F Series. POWER INPUT DC power R: 24 V DC (Operational voltage range: ±10 %; ripple 10 %p-p max.)

Flow Measurement. SITRANS F M System information SITRANS F M electromagnetic flowmeters. 4/22 Siemens FI

Dimensional drawing face mount flange radial. R = bending radius min. 40 mm. Dimensional drawing face mount flange axial

Welcome. Functionality and application of RTD Temperature Probes and Thermocouples. Dipl.-Ing. Manfred Schleicher

Explosion-protected recessed ceiling LED-light and fluorescent light fittings

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH1BVW S/08

Transcription:

TF 0 / TF 0-Ex Field mounted temperature transmitters, FOUNDATION Fieldbus (H), Pt 00 (RTD), thermocouples, or independent channels 0/-8.69 EN USA Input Resistance thermometer (,, wire circuit) Thermocouples Resistance remote signalling unit (0...500 Ω, 0...000 Ω) Voltages, mv calibrator(-5...+00 mv) Input functionality or channels Electrcal isolation (I/O) Digital, long-term solid processing of measuring values Customer-specific linearization Continuous sensor and self-monitoring EMC acc. to EN 66 and NAMUR recommendation NE Parameterization via DD and CFF file Output FOUNDATION Fieldbus (H) according to specification. Certified with Interoperbility Test Kit IT Campaign Number: IT 05000 Bus design according to IEC 658-,.5 kbit/s Backup LAS function Reserve voltage protection and solid bus current limitation Approvals for explosion protection intrinsically safe ATEX (FM, CSA in preparation) pressure proof enclosure/flameproof ATEX pressure proof enclosure, Explosionproof (acc. Divisions) FM, CSA in preparation suitable for connecting to systems according to: Entity model FISCO model

TF 0 / TF 0-Ex Field mounted temperature transmitters, FOUNDATION Fieldbus (H) 0/-8.69 EN USA Technical data Output Digital output signal Transmission rate (Baude rate) Nominal current consumption Max.current in case of device failure Damping (programmable) FOUNDATION Fieldbus (H).5 kbit/s 0.5 ma 5 ma t 6 = 0...0 8 s Input Resistance (temperature linear) Resistance thermometer n Pt00 bis Pt000 (IEC 75: n = 0.; 0.5; ; ; 5; 0) (JIS 60: n = 0.; 0.5; ; ; 0) (SAMA: n = 0.; 0.5; ) Ni50, Ni00, Ni0, Ni000 Cu0, Cu00 Resistance Range Accuracy 0...500 Ω mω 0...000 Ω 0 mω Max. line resistance (R W ) per core,, wire 5 Ω, 0 Ω, 50 Ω Measuring current 00 µa Sensor short-circuit < 5 Ω Sensor break (temperature / resistance measurement,,, wire) Measuring range 0... 500 Ω > 50 Ω Measuring range 0...000 Ω > 00 Ω Sensor wire break monitoring in accordance with NAMUR Sensor wire break detection wire resistance measurem. > 5 Ω wire resistance measurem. >.7 kω Input filter 50/60 Hz Thermocouples Types B, C, D, E, J, K, L, N, R, S, T, U Voltages Range Accuracy -00 mv...+00 mv 0 µv - 75 mv...+ 75 mv µv Sensor monitoring current µa between the measuring cycles Sensor wire break monitoring in accordance with NAMUR Thermocouple measurement > 5 kω Voltage measurement > 5 kω Input filter 50/60 Hz Internal reference junction Pt 00, via software switchable (no jumper necessary) Power supply (at transmitter terminals) Supply voltage U s = 9... V DC for explosion protection application U i = 9... V DC Supply voltage, poling protected Input element Standard Sensor IEC 58- Thermocouple Type B Thermocouple Type E Thermocouple Type J Thermocouple Type K Thermocouple Type R Thermocouple Type S Thermocouple Type T Thermocouple Type N W, Thermocouple Type C ASTME 998 Thermocouple Type D DIN 70 Thermocouple Type L Thermocouple Type U IEC 75; JIS; SAMA ) Resistance thermometer Pt00, and -wire Resistance thermometer Pt000 DIN 760 ) Resistance thermometer Ni00, and -wire Resistance thermometer Ni000 (a = 0.0068) Resistance Ω, and -wire Measuring range 0...+80 C (+...+08 F) 70...+000 C ( 5...+8 F) 0...+00 C ( 6...+9 F) 70...+7 C ( 5...+50 F) 50...+768 C ( 58...+5 F) 50...+768 C ( 58...+5 F) 70...+ 00 C ( 5...+ 75 F) 70...+00 C ( 5...+7 F) 0...+5 C (+...+00 F) 0...+5 C (+...+00 F) 00...+ 900 C ( 8...+65 F) 00...+ 600 C ( 8...+ F) 00...+ 850 C ( 8...+56 F) 00...+ 850 C ( 8...+56 F) 60...+ 50 C ( 76...+ 8 F) 60...+ 50 C ( 76...+ 8 F) 0...500 Ω / 0...000 Ω Voltage mv 00 mv...+00 mv 75 mv...+ 75 mv ) ) IEC 75 a = 0.0085; JIS a = 0.0096; SAMA a = 0.0090 Edison Curve No. 7 for Ni0 Page of 6 05.0

TF 0 / TF 0-Ex Field mounted temperature transmitters, FOUNDATION Fieldbus (H) 0/-8.69 EN USA Technical data General characteristics Rise time < 0.5 s Vibration resistance Vibration in operation g acc. to DIN IEC 68T.-6 Resistance to shock g acc. to DIN IEC 68T.-7 Electrical isolation (I/O).5 kv AC Long-term stability 0. % p. a. or 0. K p. a. Environment conditions Ambient temperature range -0...+85 C Transport and storage temperature -0...+00 C Relative humidity < 00 % (00 % humidity with isolated terminals only) condensation permitted Mechanical construction Dimensions cf. dimensional drawing Weight.5 kg (without accessories) Housing material Aluminium/stainless steel Color (Epoxy) light grey (RAL 900) Elektrical connection Thread (alternatively) x M0 x.5; x / NPT x / NPT; x / GK or with cable screw connections x M0 x,5 (metal) Ground screw external/internal 6 mm M 5 /.5 mm M Terminals, pluggable.5 mm, screw terminals (stainless steel screws) Electromagnetic compatibility (EMC) According to NAMUR NE recommendation With PT00 Sensor and Thermocouple Type of test Degree Standard burst to signal/ kv EN 6000-- data lines EN 66 static disgarge EN 6000-- contact discharge to: contact plate 8 kv terminals 6 kv radiated field EN 6000-- 80 MHz... GHz 0 V/m coupling EN 6000--6 50 khz - 80 MHz 0 V Influences Influence of ambient temperature Pt 00 ±0,5 K/0 K resistance measurement 0...500 Ω ± 0 mω/0 K 0...000 Ω ±00 mω/0 K Thermocouple e. g. Typ K ±0,5 K/0 K voltage measurement -00 mv...+00 mv ±50 µv/0 K - 75 mv...+ 75 mv ± 0 µv/0 K Characteristics at rated conditions acc. to IEC 770 (related to 5 C) Measuring error incl. characteristic deviation Pt 00 ±0, K resistance measurement 0...500 Ω ± 0 mω 0...000 Ω ±0 mω Thermocouple e. g. Typ K ±0,5 K voltage measurement -00 mv...+00 mv ±50 µv - 75 mv...+ 75 mv ±0 µv Additional influence of the Pt00 DIN IEC 75 Kl. B internal reference junction Parameterization / structure Type of input ( independant Channels), measuring range, input filter, Damping, alarm function, limit values, safing all data proof against mains failure Standard parameter (factory settings) Channel Pt00, wire circuit, 0 +00 C damping 0 s, unit C Channel disabled 05.0 Page of 6

TF 0 / TF 0-Ex Field mounted temperature transmitters, FOUNDATION Fieldbus (H) 0/-8.69 EN USA Technical data Explosion protection Intrinsically safe Zone 0 Zone 0 Zone Mine (TF 0-Ex M) EC Certificate II G EEx ia IIC T6 T T5 Ambient temperature: -0 +60 C T6 Ambient temperature: -0 +50 C T T Ambient temperature: -0 +85 C T5 Ambient temperature: -0 +65 C T6 Ambient temperature: -0 +50 C I M EEx ia I Ambient temperature: -0 +60 C DMT 0 ATEX E068 X Dust II D EEx [ia] ib (proposed) Supply circuit Supply and Communication-circuit ia/ib IIC Supply and Communication-circuit ia/ib IIB Suitable for connceting to systems according to Entity model and FISCO model Measuring circuit ia/ib Max. voltageg U i V U i V U o = 5,5 V Short-circuit current I i = 60 ma I i = 80 ma I o < 5 ma Max. power P i =,5 W P i = 5, W P o < 5 mw Internal inductance L i 0 µh L i 0 µh neglectable Internal capacitance C i = 5 nf C i = 5 nf C i = 60 nf Non sparking na ATEX Zone (TF 0-Ex N) II G EEx n A II T6 (in preparation) T T Ambient temperature: -0 +85 C T...T5 Ambient temperature: -0 +65 C T...T6 Ambient temperature: -0 +50 C Pressure proof enclosure/flameproof (TF 0-Ex d) II G EEx d IIC T6 EC Certificate T T Ambient temperature:-0 +85 C T...T5 Ambient temperature:-0 +65 C T...T6 Ambient temperature:-0 +50 C PTB 99 ATEX X Canadian Standards Association and Factory Mutual (FM and CSA approvals in preparation) Intrinsically Safe FM/CSA Class I Div. /Div., Groups A, B, C, D T6 Class II Div. /Div., Groups E, F, G FM Class I Zone 0, AEx ia or Zone 0, AEx ib IIC Nonincendive FM/CSA Class I Div., Groups A, B, C, D T6 Class II Div., Groups F, G Explosionproof FM/CSA Class I Div. /Div., Groups A, B, C, D T6 Class II Div. /Div., Groups E, F, G Block diagram Sensor ; (T) Value_ (T) AI Block AI out value sensor + Status Transducer Block TB Value_ (T) AI Block AI out value sensor + Status Sensor ; (T) Resource Block Reference junction Pt00 by request only read by request read/write Page of 6 05.0

TF 0 / TF 0-Ex Field mounted temperature transmitters, FOUNDATION Fieldbus (H) 0/-8.69 EN USA Ordering information Catalog No. EUR Deliv. time TF 0 / TF 0-Ex V56- wks. Bus system FOUNDATION Fieldbus (H) acc. to Fieldbus standard IEC-658-;,5 kbit/s LAS functionality standard FR - LAS functionality among using in combination with FIO00 from ABB FA - Explosion protection TF 0 (without explosion protection) 898,00 * Type of protection: Non Sparking "na" ATEX TF 0-Ex N DMT/ATEX Zone : II G EEx n A II T6 (Zone in preparation) 9,00 * on request Type of protection: intrinsically safe ATEX TF 0-Ex DMT/ATEX Zone 0: II G EEx ia IIC T6 5 9,00 * on request Dust: II d EEx [ia] ib (Dust certificate proposed) Type of protection: intrinsically safe FM &CSA (in preparation) expected to be available in Q 00 TF 0-Ex FM IS: Class I, Div. /Div., Groups A, B, C, D T6 9,00 * on request Class II, Div. /Div., Groups E, F, G Class I, Zone 0, AEx ia or AEx ib IIC nonincendive: Class I, Div., Groups A, B, C, D T6 Class II, Div., Groups F, G TF 0-Ex CSA IS: Class I, Div. /Div., Groups A, B, C, D T6 9,00 * on request Class II, Div. /Div., Groups E, F, G nonincendive: Class I, Div., Groups A, B, C, D T6 Class II, Div., Groups F, G Type of protection: pressure-proof enclosure / explosionproof TF 0-Ex d ATEX II G EEx d IIC T6 D 9,00 Type of protection: intrinsically safe ATEX for mine applications TF0-Ex M ATEX I M EEx ia I M 9,00 Using the TF 0-Ex M for mining, the AGSF housing in stainless steel is required. Display / construction AGLF or AGSF housing without display N - Material Aluminium AGLF housing A - Stainless steel AGSF housing (Required for TF 0-Ex M with intrinsically safe for mine) E 5,00 * Connections with cable screw connection pieces M 0 x,5 cable screw connection ) M,0 * pieces pressure proof cable screw connection ) D 0,0 * M connector M (Turck) and M 0 x,5 T 5,70 * M connector M (Weidmüller) and M 0 x,5 W 6,70 * Thread M 0 x,5 - (without cable screw connection) /" NPT - /" NPT - /" GK - Mounting field housing without - Wall mounting (carbon steel) 6,0 * Wall mounting (stainless steel) 9,50 * " Pipe mounting (carbon steel),0 * " Pipe mounting (stainless steel) 5 5,00 * Programming Factory standard parameter Pt 00 wire circuit, channel, 0 00 C, Damping off S - Customer-specified parameter definition (all parameter without user curve) K,90 * Accessories Catalog No. EUR Deliv. time Simulation plug for TF 0 / TF 0 with bus system FOUNDATION Fieldbus 795785,80 * ) Metal screw connection EEx e or EEx d (cable-diameter.5 8.7 mm) 05.0 Page 5 of 6

TF 0 / TF 0-Ex Field mounted temperature transmitters, FOUNDATION Fieldbus (H) 0/-8.69 EN USA Connection diagram + Output Microprocessor Input Ch ϑ Ch Ch Ch - Foundation Fieldbus (H) Reference junction ϑ ϑ ϑ Ch ϑ Ch Ch ϑ Ch a) b) c) d) e) f) g) h) i) j) a) Resistance thermometer, wire circuit b) Resistance thermometer, wire circuit c) Resistance thermometer, wire circuit d) Double resistance thermometer, wire circuit e) Potentiometer input ( wire circuit) Resistance measurement analogous zu to Resistance thermometer circuits a) to d) f) Thermocouple g) Double thermocouple h) Combination thermocouple resistance thermometer (Combination Ch/pin -: RTD und Ch/pin -: TC also possible) i) Voltage measurement j) Double voltage measurement Voltage measurement and Resistance Measurement analogous to circuit h) also possible Dimensional diagram (dimensions in mm) 90 97 8 5 electrical connections thread equipotential bonding screw M5 lock screw Wall mounting 0 M8 0 7 8 ~0 7 5 Pipe mounting ABB Automation Products GmbH Borsigstr. 6755 Alzenau Germany Tel: +9 60 9-0 Fax: +9 60 9-0 http://www.abb.com Subject to technical changes. Printed in the Fed. Rep. of Germany Data Sheet 0/-8.69 EN USA 05.0