A Prying Action Force and Contact Force Estimation Model for a T-Stub Connection with High-Strength Bolts

Similar documents
SIMPLE MODEL FOR PRYING FORCES IN T-HANGER CONNECTIONS WITH SNUG TIGHTENED BOLTS

2014 International Conference on Computer Science and Electronic Technology (ICCSET 2014)

Concepts of Stress and Strain

FINITE ELEMENT ANALYSIS OF THE ROTATION CAPACITY OF BEAM-TO-COLUMN END-PLATE BOLTED JOINT

Purpose of this Guide: To thoroughly prepare students for the exact types of problems that will be on Exam 3.

FE-Analysis of Stringer-to-floor-beam Connections in Riveted Railway Bridges

Local Buckling. Local Buckling in Columns. Buckling is not to be viewed only as failure of the entire member

Experimental investigation on monotonic performance of steel curved knee braces for weld-free beam-to-column connections

Modeling the bond of GFRP and concrete based on a damage evolution approach

Example 4: Design of a Rigid Column Bracket (Bolted)

IN-PLANE BUCKLING BEHAVIOR OF PITCHED ROOF STEEL FRAMES WITH SEMI-RIGID CONNECTIONS N. Silvestre 1, A. Mesquita 2 D. Camotim 1, L.

Steel Cross Sections. Structural Steel Design

BLOCK SHEAR BEHAVIOUR OF COPED STEEL BEAMS

SIMILARITY METHODS IN ELASTO-PLASTIC BEAM BENDING

BEHAVIOR OF BOLTED TOP-SEAT ANGLE CONNECTIONS UNDER COMBINED AXIAL TENSION AND MOMENT LOADING

MODULE F: SIMPLE CONNECTIONS

Behavior of bolted angle connections subjected to combined shear force and moment

MECE 3321 MECHANICS OF SOLIDS CHAPTER 3

Riveted Joints and Linear Buckling in the Steel Load-bearing Structure

Mechanics of Materials Primer

Mechanics of Solids. Mechanics Of Solids. Suraj kr. Ray Department of Civil Engineering

: APPLIED MECHANICS & STRENGTH OF MATERIALS COURSE CODE : 4021 COURSE CATEGORY : A PERIODS/ WEEK : 5 PERIODS/ SEMESTER : 75 CREDIT : 5 TIME SCHEDULE

NUMERICAL SIMULATION OF FLANGE-BOLT INTERACTION IN WIND TUBRINE TOWER CONNECTIONS

Exact Shape Functions for Timoshenko Beam Element

2012 MECHANICS OF SOLIDS

Modelling of the behaviour of beam-to-column connections at elevated temperature

Moment redistribution of continuous composite I-girders with high strength steel

Low Cycle Fatigue Behavior of a Reduced End Plate Moment Connection (T-Stub)

The Seat Angle Role on Moment-Rotation Response of Bolted Angle Connections

Project data Project name Project number Author Description Date 26/04/2017 Design code AISC dome anchor. Material.

ME 2570 MECHANICS OF MATERIALS

Karbala University College of Engineering Department of Civil Eng. Lecturer: Dr. Jawad T. Abodi

AN IMPROVED EFFECTIVE WIDTH METHOD BASED ON THE THEORY OF PLASTICITY

Junya Yazawa 1 Seiya Shimada 2 and Takumi Ito 3 ABSTRACT 1. INTRODUCTION

[5] Stress and Strain

TORSION INCLUDING WARPING OF OPEN SECTIONS (I, C, Z, T AND L SHAPES)

COURSE TITLE : APPLIED MECHANICS & STRENGTH OF MATERIALS COURSE CODE : 4017 COURSE CATEGORY : A PERIODS/WEEK : 6 PERIODS/ SEMESTER : 108 CREDITS : 5

RESILIENT INFRASTRUCTURE June 1 4, 2016

Chapter 4. Test results and discussion. 4.1 Introduction to Experimental Results

BE Semester- I ( ) Question Bank (MECHANICS OF SOLIDS)

FURTHER RESEARCH ON CHORD LENGTH AND BOUNDARY CONDITIONS OF CHS T- AND X-JOINTS

Influence of column web stiffening on the seismic behaviour of beam-tocolumn

D : SOLID MECHANICS. Q. 1 Q. 9 carry one mark each. Q.1 Find the force (in kn) in the member BH of the truss shown.

Joint resistance M j,rd Elastic limit 2/3 M j,rd

INFLUENCE OF FLANGE STIFFNESS ON DUCTILITY BEHAVIOUR OF PLATE GIRDER

A numerical investigation of local web buckling strength and behaviour of coped beams with slender web

Mechanical Properties of Materials

twenty steel construction: columns & tension members ARCHITECTURAL STRUCTURES: FORM, BEHAVIOR, AND DESIGN DR. ANNE NICHOLS FALL 2013 lecture

[8] Bending and Shear Loading of Beams

Simulation of inelastic cyclic buckling behavior of steel box sections

CIVIL DEPARTMENT MECHANICS OF STRUCTURES- ASSIGNMENT NO 1. Brach: CE YEAR:

POST-PEAK BEHAVIOR OF FRP-JACKETED REINFORCED CONCRETE COLUMNS

A NEW HYBRID TESTING PROCEDURE FOR THE LOW CYCLE FATIGUE BEHAVIOR OF STRUCTURAL ELEMENTS AND CONNECTIONS

Prediction of moment rotation characteristic of top- and seatangle bolted connection incorporating prying action

INFLUENCE OF FRICTION PENDULUM SYSTEM ON THE RESPONSE OF BASE ISOLATED STRUCTURES

ENG1001 Engineering Design 1

BIAXIAL STRENGTH INVESTIGATION OF CFRP COMPOSITE LAMINATES BY USING CRUCIFORM SPECIMENS

Finite Element Modelling with Plastic Hinges

QUESTION BANK SEMESTER: III SUBJECT NAME: MECHANICS OF SOLIDS

3. Stability of built-up members in compression

Failure in Flexure. Introduction to Steel Design, Tensile Steel Members Modes of Failure & Effective Areas

Tension Members. ENCE 455 Design of Steel Structures. II. Tension Members. Introduction. Introduction (cont.)

CONNECTION DESIGN. Connections must be designed at the strength limit state

Lap splice length and details of column longitudinal reinforcement at plastic hinge region

The subject of this paper is the development of a design

Job No. Sheet 1 of 6 Rev B. Made by IR Date Oct Checked by FH/NB Date Oct Revised by MEB Date April 2006

A numerical parametric study on the plate inclination angle of steel plate shear walls

NORMAL STRESS. The simplest form of stress is normal stress/direct stress, which is the stress perpendicular to the surface on which it acts.

Application nr. 7 (Connections) Strength of bolted connections to EN (Eurocode 3, Part 1.8)

Thermal and mechanical modeling of thermal breaks in structural steel point transmittances

CHAPTER 2 LITERATURE REVIEW

PLATE GIRDERS II. Load. Web plate Welds A Longitudinal elevation. Fig. 1 A typical Plate Girder

An investigation of the block shear strength of coped beams with a welded. clip angles connection Part I: Experimental study

Steel connections. Connection name : MEP_BCF_W=14.29[mm]_W=6.35[mm]_tp=63.5[mm]_N=0_N=2_N=0_N=1_W=14.29[mm]_W=14.29[mm]_W=14.29[ mm] Connection ID : 1

Influence of residual stresses in the structural behavior of. tubular columns and arches. Nuno Rocha Cima Gomes

STEEL JOINTS - COMPONENT METHOD APPLICATION

PLASTIC RESISTANCE OF L-STUBS JOINTS SUBJECTED TO TENSILE FORCES

Structural Steelwork Eurocodes Development of A Trans-national Approach

MECHANICS OF MATERIALS

Unified Design Criteria for Steel Cantilever Plate Connection Elements. Pouya Salem

FCP Short Course. Ductile and Brittle Fracture. Stephen D. Downing. Mechanical Science and Engineering

GEOSYNTHETICS ENGINEERING: IN THEORY AND PRACTICE

Structural Steelwork Eurocodes Development of A Trans-national Approach

FHWA Bridge Design Guidance No. 1 Revision Date: July 21, Load Rating Evaluation of Gusset Plates in Truss Bridges

two structural analysis (statics & mechanics) APPLIED ACHITECTURAL STRUCTURES: DR. ANNE NICHOLS SPRING 2017 lecture STRUCTURAL ANALYSIS AND SYSTEMS

ERRATA for PE Civil Structural Practice Exam ISBN Copyright 2014 (July 2016 Second Printing) Errata posted

Behaviour of Continuous Beam to Column Connections in Post Earthquake Fire

An Increase in Elastic Buckling Strength of Plate Girder by the Influence of Transverse Stiffeners

The Non Linear Behavior of the Microplane Model in COMSOL

five Mechanics of Materials 1 ARCHITECTURAL STRUCTURES: FORM, BEHAVIOR, AND DESIGN DR. ANNE NICHOLS SUMMER 2017 lecture

A study of action point correction factor for L type flanges of wind turbine towers

THEME IS FIRST OCCURANCE OF YIELDING THE LIMIT?

ENCE 455 Design of Steel Structures. III. Compression Members

QUESTION BANK DEPARTMENT: CIVIL SEMESTER: III SUBJECT CODE: CE2201 SUBJECT NAME: MECHANICS OF SOLIDS UNIT 1- STRESS AND STRAIN PART A

Modeling of welded angle connections in fire

DYNAMIC ANALYSIS OF PILES IN SAND BASED ON SOIL-PILE INTERACTION

Samantha Ramirez, MSE. Stress. The intensity of the internal force acting on a specific plane (area) passing through a point. F 2

The Local Web Buckling Strength of Coped Steel I-Beam. ABSTRACT : When a beam flange is coped to allow clearance at the

RECENT DEVELOPMENTS IN THE BEHAVIOUR OF STEEL AND COMPOSITE CONNECTIONS IN FIRE

Seismic Pushover Analysis Using AASHTO Guide Specifications for LRFD Seismic Bridge Design

Transcription:

A Prying Action Force and Contact Force Estimation Model for a T-Stu Connection with High-Strength Bolts Jae-Guen Yang* 1, Jae-Ho Park, Hyun-Kwang Kim and Min-Chang Back 1 Professor, Department of Architectural Engineering, College of Engineering, Inha University, Korea Graduate Student, Department of Architectural Engineering, College of Engineering, Inha University, Korea Astract A T-stu connection with high-strength olts under tensile force is affected y prying action force and the contact force, among others, etween memers. If a design equation that does not consider such prying action force and contact force etween memers is not proposed, the T-stu under tensile force is liale to e fractured under a strength lower than the estimated design strength. To prevent this, many studies have proposed contact force estimation equations etween memers as well as the prying action force of the T-stu connection with high-strength olts. However, no design equations ased on such research have een proposed in South Korea. Therefore, this study aims to propose an estimation model for more accurate prying action force and contact force, and to improve on previously proposed estimation models y implementing three-dimensional, nonlinear finite element analysis. Keywords: prying action force; contact force; design strength; connection stiffness 1. Introduction Bolted connections under tensile force are liale to e fractured under a strength lower than the estimated design strength due to the prying action force or contact force etween memers. Thus, there have een many studies on estimating such prying action force and contact force etween memers, which have proposed various estimation models. Douty and McGuire (1965) estimate prying action force ased on elastic analysis. In proposing an estimation model, they considered the material properties of high-strength olts and connecting memers as well as the geometric shape of connections. Similarly, Agerskov (1976) estimated prying action force ased on elastic analysis. Agerskov's estimation model considered the deformation of T-stu flanges connected with high-strength olts and shear deformation, ut did not consider non-linearity ased on flange yielding. Struik and Back (1969) estimated the prying action force of connections that have generally geometric shapes ased on the comination of high-strength olts and T-stu flanges. Struik and Back's estimation model, which is most widely used, however, offers a value larger than the prying action *Contact Author: Jae-Guen Yang, Professor, Department of Architectural Engineering, College of Engineering, Inha University, #53 Young Hyun-Dong, Nam-Ku, Incheon, 40-751, South Korea Tel: +8-3-860-7588 Fax: +8-3-866-464 E-mail: jyang@inha.ac.kr ( Received Octoer 10, 01 ; accepted July 3, 013 ) force acquired from the action test. Assuming that the central line of the axial olt force moves y the contact force etween memers, Swanson (1999, 00) proposed an estimation model, which improved the estimation model y Struik and Back. However, the application of the estimation model has ecome more complex. Jaspart and Maquoi (1995) oserved the change in contact force etween connection memers according to olt pretension, and showed that such a change affects the tensile stiffness of connections under tensile force. Faella et al. (1996, 1998) oserved the change in contact force etween connection memers according to the change in the stiffness ratio (ß) etween the flexural stiffness of the connecting memer flanges and the axial tensile stiffness of highstrength olts, and estimated the change in the axial tensile stiffness of the connections. This study aimed to improve the previous contact force estimation models etween memers and the prying action force. Toward this end, it performed the three-dimensional non-linear finite element analysis. The feasiility of the proposed estimation model was verified after a comparison and review of the analysis results of other researchers.. Three-Dimensional Non-linear Finite Element Analysis Modeling of Connections with High- Strength Bolts The prying action force of the connection with highstrength olts and the contact force etween memers were estimated y the three-dimensional non-linear finite element analysis. Generally, the contact effect of the memers and the prying action is largest when the Journal of Asian Architecture and Building Engineering/Septemer 013/316 309

connecting flange is thinnest, and the gauge distance etween high-strength olts is largest. Based on Kulak's research, Thornton (1985) and Astaneh (1985) proposed parameter α', as in Eq. (1), to determine the effect of prying action. In proposing Eq. (1), δ, the parameter that shows the effect of the olt hole for high-strength olts on the elements under prying action force, is the ratio etween the net section area of the flange and the gross sectional area, and ρ is the ratio of the distance etween the central line of the axial load of the highstrength olt and the distance etween the central line of the axial load of the high-strength olt to the T-stu stem surface. The prying action effect is highly likely to occur when α', which is affected y the geometric shape of the connection, the pretension force of the high-strength olts, and the material properties of the connection are larger than 1.0. Therefore, as shown in Fig.1. and Tale 1., this study selected the geometric shape of the connection with two α' values such as α' > 1.0 and 0 < α' < 1.0, respectively. The steel material used in the connection is SS400, and as shown in Fig.., the material properties are in a ilinear model, which is descried y the regression analysis in Tale. F10T-M0 high-strength olts were idealized as having een connected y 165kN pretension. 1 t c ' 1 1 t f t 8 B ' 0 c () pfy ' (3) a' ' 1 d (4) p d a' a (5) d ' (6) (1) Fig.1. Geometric Shape of the Connection Fig.. Stress-Strain Curve of Steel Material The connection with high-strength olts was modeled y ABAQUS (ver. 6.9.). The T-stu that comprises the connection is a C3D8R (eight-node rick element with reduced integration) memer element. In performing the three-dimensional non-linear finite element analysis, the effect of the contact and earing etween memers as well as the pretension of the high-strength olts were considered. The frictional coefficient etween memers was set to 0.5. This frictional coefficient was applied under the assumption that the faying surfaces etween memers are unpainted, last-cleaned steel surfaces. The Korean Building Code (KBC009) only provides the case of μ = 0.5. For high-strength olts used in the T-stu analytical model, the horizontal movement was restrained y inserting the plate, which is 1.5 times thicker than the T-stu flange etween the lower T-stu and the upper T-stu. As shown in Fig.3., the overall connection analysis model consists of a total of 40,716 elements and 55,376 nodes, and the analysis of each model lasted aout 40 minutes. In modeling the connection with high-strength olts, the applied ABAQUS options are as shown in Tale 3. Tale 1. Geometric Variales of the T-Stu Analytical Model (Unit: mm) Analytical model f t w t f g t r a T p e l T α' G60-T15-B350 350 15 15 60 45 1.5 100 100 50 400 7.58 G310-T15-B400 400 15 15 310 45 147.5 100 100 50 400 8.14 G60-T19-B350 350 1 19 60 0 45 14 100 100 50 400 4.59 G310-T19-B400 400 1 19 310 0 45 149 100 100 50 400 4.96 G60-T1-B350 350 13 1 60 45 13.5 100 100 50 400 3.67 G310-T1-B400 400 13 1 310 45 148.5 100 100 50 400 3.98 G110-T8-B00 00 18 8 110 45 46 100 100 50 400 0.58 G140-T8-B30 30 18 8 140 45 61 100 100 50 400 0.98 G110-T35-B00 00 0 35 110 45 45 100 100 50 400 0.08 G140-T35-B30 30 0 35 140 45 60 100 100 50 400 0.37 Tale. Material Properties of the T-Stu Specimen F y (N/mm ) F u (N/mm ) ε y ε u E (N/mm ) E h (N/mm ) 347.33 518.78 0.00161 0.09451 15,446.40 1,814.04 310 JAABE vol.1 no. Septemer 013 Jae-Guen Yang

Also, it is assumed that the prying action force is applied to the end of the flange. However, as pointed out y Kulak et al. (001), Eq. (7) results in excessive prying action force. Q T Struik & Back ' ' (1 ') a' (7) (a) G60-T15-B350 analysis model Kulak et al. proposed the axial tensile force on the high-strength olts of the connection under tensile force, as in the following Eq. (8). The coefficient 1.6 in Eq. (8) includes the effect of prying action force. EA k 1.6 L (8) tnth L tt, top tfl, col ' n twh (9) Fig.3. Finite Element Analysis Model of the Connection with High-Strength Bolts Tale 3. ABAQUS Options for Finite Element Analysis Contact surface Command Option Washer contact Constraints surface Tie T-stu T-stu T-stu Highstrength olt Nut - Highstrength olt () G140-T8-B30 analysis model Contact Contact Contact Finite sliding Finite sliding Allow separation after contact Allow separation after contact Small sliding Adjust only to remove over closure Adjust only to remove over closure Adjust only to remove over closure 3. Estimation of the Prying Action Force on the Connection with High-Strength Bolts and the Contact Force etween Memers In the case of axial tensile force on the connection with high-strength olts, as shown in Fig.4., Struik and Back proposed the ratio Q/T, as in Eq. (7), Q is the prying action force, and T is the axial tensile force. In using Eq. (7), if α' is larger than 1.0, that is, the connection is fractured y the plastic deformation after the flexural yielding of the flange due to the prying action force, α' is set to 1.0. On the other hand, if α' is etween 0 and 1, that is, the connection is fractured y partial yielding of the flange followed y olt failure, α' is set to the value directly otained from Eq. (1). Fig.4. Prying Action Force Estimation Model y Struik and Back Faella et al. assumed that, as in Fig.5., the contact force etween the high-strength olt head and the connection flange at an angle of 45º would occur due to the pretension of the high-strength olt. Also, they proposed K p /K, the ratio of the high-strength olt stiffness to the connection flange stiffness under such contact force, as in Eq. (10), which offers similar values to those of the equations proposed y Agerskov and Bursi (1990). In the application of Eq. (10), K p can e otained through the application of deformaility characteristics y decompression. The value, A(z), used in Eq. (11) signifies the area of the T-stu flange compressed y the axial force of high-strength olts. Kp tp 4.10 3.5 (10) K d K p t t p wh 0 1 1 dz EA() z (11) 4. Three-Dimensional Nonlinear Finite Element Analysis Result on the Connection with High- Strength Bolts If a connection with α' > 1.0, linked with the highstrength olts, is under the axial tensile force, the JAABE vol.1 no. Septemer 013 Jae-Guen Yang 311

Fig.5. Contact Force Distriution Characteristics Due to the Pretension of the High-Strength Bolt connection is fractured y plastic deformation after the flexural yielding of the flange. Whereas a connection is fractured y partial yielding of the flange followed y olt failure if the connection with 0 < α' < 1.0. Shown in Fig.6. is the stress distriution on the connection when the applied load reaches the reference load, which, as defined y Richard et al. (1988), is the value at which the slope of the region that shows the strain hardening symptom of the connection meeting the y-axis and the load axis. As shown in Fig.6.(a), the flexural yielding occurs y the concentrated stress in the area, which is at a certain distance from the T-stu fillet and the area at which the end of the interior of the high-strength olt head and the T-stu flange meet when 3.67 < α' < 8.14. On the other hand, as shown in Fig.6.(), the flexural yielding only occurs y the concentrated stress in the area at which the end of the interior of the highstrength olt head and the T-stu flange meet when 0.08 < α' < 0.98. Such concentrated stress shows the plastic hinge line in a eam pattern, as predicted y Faella et al. as well as Ballio and Mazzolani (1994), and results in a fracture. Shown in Fig.7. is the applied load-olt force relationship curves of the T-stu connection, resulting from the three-dimensional non-linear finite element analysis result, which shows very similar ehavioral characteristics to those of the same curve from Struik and Back's test. In other words, with the increase in the applied load, the axial olt force of the highstrength olt also gradually increases, and after the reference load, such an increase of the axial olt force accelerates, resulting in the failure of the high-strength olt. Such a rapid increase of the axial olt force of the axial olt force on the high-strength olt is elieved to e due to the prying action effect. According to the three-dimensional non-linear finite element analysis result, the average increase rate of the axial olt force on the high-strength olt due to the prying action effect is 8.% when 3.67 < α' < 8.14, as shown in Tale 4., resulting in 3.8 of the axial olt force ratio of the high-strength olt to the applied load. This ratio is much larger than that referred to y Eq. (8). That is, the prying action effect is excessive since each connection with 3.67 < α' < 8.14 has much thinner flange thickness and larger olt gauge distance than the connection with α' = 1.0. On the other hand, the average increase rate of the axial olt force on the high-strength olt due to the prying action effect is 11.4% when 0.08 < α' < 0.98, as shown in Tale 5. Therefore, the following Eq. (1) was proposed y applying a revised parameter to Eq. (7), which offered excessive Q/T, ased on the three-dimensional finite (a) T 0 =383.3kN, G60-T15-B350 analysis model () T 0 =1,958.1kN, G140-T8-B30 analysis model (c) T final =770.3kN, G60-T15-B350 analysis model (d) T final =1,970.5kN, G140-T8-B30 analysis model Fig.6. Connection Stress Distriution Under Reference Load 31 JAABE vol.1 no. Septemer 013 Jae-Guen Yang

element analysis result. In addition, if the equilirium equation (B = T + Q) among T, the applied load, B, the axial force of high-strength olts, and Q, the prying action force, is applied, the correlation etween the applied load and the axial force of high-strength olts is summarized in Eq. (13). As shown in Eq. (13), the aove-mentioned value of 3.8 is the sum of.8, the average increase in the ratio of the prying action force, as summarized in Tale 4., and 1.0. As shown in the following Eq. (14), the tensile stiffness of highstrength olts is summarized from the correlation, R.05 if ' 1.0 R 0.4 if 0 ' 1.0 k, Yang EA EA ' ' L m Q L 1 R 1 (1 ') a' m m T Yang a' a 0.3d m ' 0.3d m (14) (15) (16) (a) G310-T1-B400 analysis model () G110-T8-B00 analysis model Fig.7. Applied Load vs. Axial Bolt Force Relationship Curve on the High-Strength Bolt of the T-Stu Connection etween the constitutive equation on the high-strength olts and the axial force of high-strength olts. That is, the tensile stiffness of a couple of high-strength olts is affected y the prying action force, as shown in Eq. (14), and it is reflected in the value, 1.6, the coefficient mentioned in Eq. (8). In implementing Eq. (15) and Eq. (16), a' m and ' m are defined as the distance from the central line of the axial force of the high-strength olt to the end of the flange and the distance from the central line of the axial force of the high-strength olt to the stem, respectively. As the load acting on T-stu increases, the stress that occurs in the shank of highstrength olts moves from the centroid point of the shrank of high-strength olts to the right, as shown in Fig.8., showing non-uniform distriution. In this case, the axial force of high-strength olts is assumed to e acting on the centroid point of non-uniform stress distriution. The centroid point of non-uniform stress distriution otained from the stress distriution that occurred in the shank of high-strength olts of each analytical model was the point that moved as much as an average of 0.3d from the central axis of highstrength olts. Q ' ' m R T (1 ') a', m Yang m B ' ' m Q 1R 1 T (1 ') a' m T, m Yang m Yang (1) (13) Fig.8. Stress Distriution of the Axial Load on the High-Strength Bolt Tale 4. Prying Action Effect Coefficient from the T-Stu Connection Analysis Result when 3.67 < α' < 8.14 Analytical model Average increase ratio of the axial load on high strength olt (%) G60-T15-B350 33. G310-T15-B400 314.6 G60-T19-B350 197.6 G310-T19-B400 47.5 G60-T1-B350 160.6 G310-T1-B400 15.4 Average increase ratio 8. Tale 5. Prying Action Effect Coefficient from the T-Stu Connection Analysis Result when 0.08 < α' < 0.98 Analytical model Average increase ratio of the axial load on high strength olt (%) G110-T8-B00 11.8 G140-T8-B30 7.5 G110-T35-B00 1.4 G140-T35-B30 4.9 Average increase ratio 11.4 JAABE vol.1 no. Septemer 013 Jae-Guen Yang 313

(a) G60-T15-B350 analysis model () G110-T8-B00 analysis model Fig.9. Contact Force Distriution Characteristics y the Pretension of the High-Strength Bolt, Resulting from the Finite Element Analysis Result The ratio of the contact force etween memers to the stiffness of the connection flange and the highstrength olt is affected y such stress distriution. According to Fig.9., the contact force etween the head of the high-strength olt and the connection flange occurs at 9º. As descried in Tale 6. and Tale 7., the contact force is exerted at a stress distriution angle, which results from the finite element analysis result, and is smaller than that proposed y Faella et al. Based on such a stress distriution angle, the stiffness ratio of the connection flange to the high-strength olt can e expressed as Eq. (17). m K K p, pretension Yang tp 3.893 0.64 d (17) Tale 6. Stress Distriution Angle Resulting from the T-Stu Connection Analysis Result when 3.67 < α' < 8.14 Analytical model Angle ( ) G60-T15-B350 10 G60-T15-B350 10 G60-T19-B350 7 G310-T19-B400 10 G60-T1-B350 8 G310-T1-B400 9 Average angle 9 to estimate the prying action effect, the normalizing factor β* should e otained y performing a finite element analysis for each connection. The test performed the three-dimensional non-linear finite element analysis again y applying the identical geometric shape, material properties, oundary conditions, and loading conditions to the T-stu finite element analysis model y Hantouche, shown in Fig.10.(a) and 10.(). The stress distriution of the T-stu model, resulting from the re-performed finite element analysis, is shown in Fig.11. As shown in Fig.1., the prying action effect of the high-strength olt, resulting from the re-analysis of the T-stu y Yang, offers a very similar prying action effect to that of the high-strength olt y Hantouche. Although Yang's analysis model showed a slightly larger Q/T value than Hantouche's analysis model for the W4x76 analysis model, the Q/T from Yang's analysis model offered a value close to that of Hantouche's analysis model. Therefore, it is determined that using Yang's analysis model is feasile. In addition, it is much easier to estimate the prying action effect of a connection since Yang's analysis model does not need to use the normalizing factor β*. The normalizing factor β* can only e otained y performing a complex finite element analysis. Tale 7. Stress Distriution Angle Resulting from the T-Stu Connection Analysis Result when 0.08 < α' < 0.98 Analytical model Angle ( ) G110-T8-B00 1 G140-T8-B30 1 G110-T35-B00 1 G140-T35-B30 Average angle 1 The feasiility of the application of Eq. (1), the proposed estimation of the prying action effect, was assessed y comparing and reviewing the result from that of the T-stu analysis, in Fig.10., which was conducted y Hantouche (011). In the development of Hantouche's model, a normalizing factor β* was used to relate the primary prying strength model to the primary prying finite element model. That is, in order a) Hantouche s T-stu specimen with continuity plates () Hantouche s T-stu specimen without continuity plates Fig.10. Hantouche's T-Stu Specimen 314 JAABE vol.1 no. Septemer 013 Jae-Guen Yang

(a) With continuity plates () Without continuity plates Fig.11. Stress Distriution from Yang's T-Stu Re-Analysis Result (a) With continuity plates () Rigid Column Fig.1. Comparison of Hantouche's Analysis Result for the W30x108 Analytical Model with t cf /t Tf =0.76 Tale 8. Comparison of the Analysis Result y Hantouche and the Analysis Model (With Continuity Plates) Analytical model t cf /t Tf Differences (%) W4x76 0.67 36.65 11.87 4.78 W30x108 0.6 30.8 31.3 1.04 W36x150 0.7 3.69.09 1.60 Tale 9. Comparison of the Analysis Result y Hantouche and the Analysis Model (Without Continuity Plates) Analytical model t cf /t Tf Differences (%) W4x76 0.67 36.65 19.85 16.80 W30x108 0.6 30.8 40.70 10.4 W36x150 0.7 3.69 39.63 15.94 5. Conclusion This study aimed to offer an improved analysis model that could estimate the prying action force of the T-stu connection with high-strength olts under tensile force, as well as the contact force etween memers. The study resulted in the following conclusions: 1) Based on the three-dimensional non-linear finite element analysis, the ratio of the axial force on the high-strength olt to the applied load y the prying action effect is 3.8 when 3.67 < α' < 8.14. Hence, it is recommended that the coefficient referred to y Eq. (8) is set to 0.609 for a connection with 3.67 < α' < 8.14. ) The three-dimensional non-linear finite element analysis result showed that the contact force is delivered at a maximum angle of 9º, the angle of the stress distriution etween the head of the high- JAABE vol.1 no. Septemer 013 Jae-Guen Yang 315

strength olt and the connection flange, which is smaller than the angle proposed y Faella et al. 3) As shown in Tale 8. and Tale 9., in estimating Q/T of the T-stu, Yang's analysis model offered a closer value to the actual test than Hantouche's analysis model did. Therefore, it is determined that estimating Q/T of the T-stu y using Yang's analysis model is valid. Acknowledgment The authors deeply appreciate the generous support of the National Research Foundation of Korea (under Research No. 01047786). 11) Richard et al. (1988) Derived moment-rotation curves for douleframing angles. Comput & Struct, Elsevier Science Ltd., 3, pp.485-494. 1) Struik, J. H. A., and de Back, J. (1969) Tests on Bolted T-stus with Respect to Bolted Beam-to-Column Connections. Report 6-69-13, Stevin Laoratory, Delft University of Technology, Delft, The Netherlands. 13) Swanson, J. A. (1999) Characterization of the Strength, Stiffness, and Ductility Behavior of T-stu Connections. Ph. D. Dissertation, Georgia Institute of Technology, Atlanta, USA. 14) Swanson, J.A. (00) Ultimate Strength Prying Models for Bolted T-Stu Connections. Engineering Journal, AISC, 39 (3), 3rd Quarter, pp.136-147. 15) Thornton, W. A. (1985) Prying action: A general treatment. Engineering Journal, AISC,, pp.67-75. List of Nomenclatures d : Diameter of the olt d': Diameter of the olt hole k : Axial tensile stiffness of the olt r: Radius of the fillet of the T-stu B 0 : Bolt pretension force used in the T-stu B: Bolt force developed y the applied load E: Young's modulus of steel E h : Secant modulus of steel F y : Yield strength of steel F u : Ultimate strength of steel Q: Prying action force of the T-stu T: Load applied to the T-stu T 0 : Reference load of the T-stu α: Value that either maximizes the olt's availale tensile strength for a given thickness or minimizes the thickness required for a given olt's availale tensile strength ε y : Yield strain of steel ε u : Ultimate strain of steel References 1) Agerskov, H. (1976) High strength olted connections suject to prying. Journal of Structural Engineering. Div., ASCE, 10(1), pp.161-175. ) Astaneh, A. (1985) Procedure For a Design and Analysis of Hanger-Type Connections. Engineering Journal, AISC, (), pp.63-66. 3) Ballio, G., Mazzolani, F.M. (1994) Strutture in A cciaio. Hoepli, Milan. 4) Bursi, O. (1990) Behaviour of High strength Bolts in Bolted Beam-to-Column connections, Proc. Of Applied Stress Analysis Conference, Nottingham. 5) Douty, R. T. and McGuire, W. (1965) High Strength Bolted Moment Connections. J. Struct. Div., ASCE, 91(), pp.101-18. 6) Faella, C., Piluso, V., Rizzano, G. (1996) Some Proposals to Improve EC3-Annex J Approach for Predicting the Moment- Rotation Curve of Extended End Plate Connections, Costruzioni Metalliche, No. 4. 7) Faella, C., Piluso, V., Rizzano, G. (1998) Experimental Analysis of Bolted Connections: Snug versus Preloaded Bolts. Journal of Structural Engineering, ASCE, 14(7), pp.765-774. 8) Hantouche, EG. (011) Behavioral characterization of uilt-up T-stu connections for use in moment resisting frames. Ph.D. dissertation, University of Cincinnati, Cincinnati, USA. 9) Jaspart, J. P. and Maquoi, R. (1995) Effect of Bolt Preloading on Joint Behaviour. Steel Structures, Eurosteel '95, edited y Kounadis, Balkema. 10) Kulak, G. L., Fisher, J. W. and Struik, J. H. A. (001) Guide To Design Criteria For Bolted and Riveted Joints nd Ed. New York: American Institute of Steel Construction. 316 JAABE vol.1 no. Septemer 013 Jae-Guen Yang