BASE. Rotary limit switch. OptiOnS. FEAtuRES. CERtiFiCAtiOnS

Similar documents
Universal limit switches

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH

Switches in conformity with ATEX directive

LD-LP-LL-LC Rope Safety Switches with reset for emergency stop

Amphenol. Amphenol-Tuchel Electronics GmbH. Circular Connectors C 091 A/B/D Series

5SJ4...-.HG Circuit Breakers to IEC and UL 489

MINIATURE MICROSWITCHES - PREMIUM

BETA Protecting. Low-Voltage Fuse Systems. LV HRC fuse links. 3/36 Siemens ET B1 2008

Amphenol. Amphenol-Tuchel Electronics GmbH. Series C 146 Heavy Duty Connectors Core Programme

8 Installation Equipment

STATIC GAS MONITOR Type SGM/DEW Revision A of 20 aprile 2016

PHOENIX CONTACT - 04/2016. Features

Installation guide 862 MIT / MIR

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22)

TeSys circuit-breakers

SUBMINIATURE MICROSWITCHES - PREMIUM

VOLUMEC. Valve Position Indicator 5

VX25 Enclosure System. Technical documentation PE conductor connection, current carrying capacity

E8EB-N0C2B E8EB-N0B2B

HARTING D-Sub Selection Guide

EX-EMERGENCY LIGHT FITTINGS

MINIATURE MICROSWITCHES - PREMIUM

SC125MS. Data Sheet and Instruction Manual. ! Warning! Salem Controls Inc. Stepper Motor Driver. Last Updated 12/14/2004

AT SERIES OFF CIRCUIT TAP CHANGERS

Pressure transmitters for industrial applications MBS 32 and MBS 33

ORTHOBLOC 3000 Drive systems Maintenance

Non-Contact Safety Systems CMS

SUBMINIATURE MICROSWITCHES - STANDARD

Absolute encoders multiturn

CDS. high density spring connection

SKF actuators available for quick delivery. Selection guide

microswitches Low force

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

ISSPRO 3 3/8 Programmable Tachometer High Performance EV Line Part Numbers R5535M, R6535M

VK2 volume flow controller Overview

Overload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011

ED 701 General Industry Pressure Transmitter

TECHNICAL INFORMATION

ROTARY CONTROLS. Rotary controls 1. GENERAL FEATURES 2. POSITION INDICATORS

Series MHY2/MHW Angular Gripper. Cam actuation style is now standardized! MHZ2 MHZJ2 MHQ MHL2 MHR MHK MHS MHC2 MHT2 MHY2 MHW2 MRHQ 2.

Thermal-Magnetic Circuit Breaker 2210-T2...

Proximity Sensor Ideal for High Temperatures and Cleaning Processes. Applicable to 120 C

ER2 Short-head Electric Chain Hoist

W250: Compact photoelectric switch series for a broad range of applications

The perfect Torque Limiting Clutch for

High-efficiency Circulator Pump. Rio-Eco N / Rio-Eco Z N. Type Series Booklet

Single Phase Motors Technical Datasheets

Conductivity sensor for hygienic applications

2/2-way ball valve with electric rotary actuator, ball valve in plastic, DN 10-50

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27

ABB SpA COMEM Operating Unit Strada Regionale 11, Signolo Montebello Vicentino (VI) - ITALY

Single Phase Motors Technical Datasheets

DRUM MOTOR DM 0080 DRUM MOTOR DM Technical data. Design variants and accessories

Analogue Meters CQ2x07 series

HPG xxx 030 C1 C2 C3. High performance angle gearboxes. Output. Input. Drawings. C with option motor flange. View x. Centering View y.

LED light engine / OLED LED compact. Umodule STARK DLE CLASSIC STARK DLE 82,8 54,4. Ordering data

BETA Protecting Miniature Circuit Breakers

Serie B2.1. Flanged ductile iron ball valve. made in. Application fields. Shut-off valves E U R O P E. 18

Thermal-Magnetic Circuit Breaker 2210-S2..

Thermal-Magnetic Circuit Breaker 2210-S2..

THE DIMENSIONING OF ELECTRICAL CONDUCTORS FOR USE IN "PANEL BOARDS" ADDRESSED TO HAZARDOUS AREAS - PART THREE

DRUM MOTOR DM 0080 DRUM MOTOR DM Technical data. Design variants and accessories

Thermal-Magnetic Circuit Breaker 2210-S2...

Thermal-Magnetic Circuit Breaker 2210-S2...

Thermal-Magnetic Circuit Breaker 2210-S2..

4.13. Ex-Floodlights of the series FMV LED / NSSFMV. (Zone 2, 22) service life and a high level of efficiency. NFMV floodlights for highpressure

WISE Damper. Active damper for Swegon s WISE System for demand-controlled ventilation QUICK FACTS

2.1. DOMINO Series DIMENSIONS QUALITY MARKS TECHNICAL CHARACTERISTICS VERSIONS BEHAVIOUR WITH CHEMICAL AND ATMOSPHERIC AGENTS. Acids.

The electronic actuator for future-proof applications

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

AC axial compact fan

ZF Series Force Transducers

HYGRASGARD KFF KFTF HYGRASGARD AFF AFTF HYGRASGARD AFF - LC AFTF - LC

W 9 L: Laser photoelectric switches: small, light and reliable

CS Series. Capacitance Type. Type. Proximity Sensor. Features

Operating Instructions for Digital Manometer. Model: MAN-SD

RoHS. Versatile. X g. X 2 e

AC axial compact fan

Lexium integrated drives

MAINTENANCE EVALUATION CHECKLIST HYDRAULIC ELEVATORS

Assembly Instructions for the 1-Wire Weather Station V2.0/V3.0

Technical Instructions 5020.B. Specification 12 ½''' Dimensions and battery. Performances. Functions. Movement height 4.40 mm

Lamp and Control Panel (Lamp Panel)

System Components. Electric Motors.

Commercial Generator Parts Catalog. PROTEC Series

Connector~Tech Providing Harsh Environment Connector

40 CD RANGE FLUSH-MOUNTING DISTRIBUTION BOARDS AND ENCLOSURES

Automatic Level Maintenance Manual SAL-XX W/ AIR DAMPENED COMPENSATOR

Imformation of C091D series

General characteristics

EVOTRON WET ROTOR ELECTRONIC CIRCULATORS TECHNICAL DATA APPLICATIONS ADVANTAGES

ZF Maschinenantriebe GmbH Industrial Drives. Planetary gearboxes Economy Series for Servomotors

Astral Tekno Cylinders

Varius SUMMARY OF MODELS OF HRC FUSE-LINKS

Product description. Compact Modules. Characteristic features. Further highlights

I nllk 08018/18 I nllk I nllk 08036/36 I nllk I I nllk 08058/58 I

Ex-Floodlights of the series FMV LED / NFMV / NSSFMV. Stainless steel NSSFMV floodlights for particularly. in harsh environments

4.2. Ex-Ceiling light fittings AB 80 / AB 05 LED / AB 05 / AB 12 NAV 70. (Zone 1, 2, 21, 22)

MR medium rating busbar

400 Volts, 50HZ 480 Volts, 60HZ 600 Volts, 60HZ TECHNICAL REFERENCE MANUAL

Transcription:

Rotary limit switch BASE Rotary limit switch used to control and measure the movement of industrial machines. Its compact size make it suitable for use in narrow spaces. FEAtuRES It consists of a gear motor that transfers movement through a primary input reduction stage (worm gear and helical toothed gear) and one or more secondary output stages (pairs of straight toothed gears). Accurate adjustment of cams by means of screws. Positive opening NC contacts for safety functions. Mechanical life of switches: million operations. IP protection degree: Base is classiied IP, IP6 or IP66, IP6 and IP6K. NEMA protection degree: Base IP66, IP6 and IP6K is classiied Type ; Base IP is classiied Type. Extreme temperature resistance: -0 C to +80 C. It features stainless steel transmission and gear driving shafts, self-lubricating technopolymer gears and driving bushes, technopolymer base and cover. Sintered bronze bushes are moulded into the base of the limit switch to optimize shaft rotation and prevent rubbing with plastic material. All materials and components used are wear resistant and guarantee protection of the unit against water and dust. OptiOnS Revolution ratios from : to :00, achieved by combining different secondary output stages. Snap action switches with NO+NC change-over contacts. It can be equipped with a cam set with maximum 6 switches. Dedicated cable clamps or connectors. Available with anti-moisture plug itted to the base by means of a lock nut, to improve transpiration for the limit switch whilst maintaining protection against water. Available with flanges, pinions and couplings. Available with direct control switches to enable direct action on the motor. CERtiFiCAtiOnS CE marking, curus* marking and EAC certiication. Complies with accident prevention regulation BGV C (only for Germany). The data and the products illustrated in this brochure may be modiied without notice. Under no circumstances can their description have a contractual value. * Not available on all versions.

possible ASSEmBliES ip with switches IP 66/IP 6/IP 6K, with switches and lange ip 66/ip 6/ip 6K, with or switches With anti-moisture plug CERtiFiCAtiOnS Conformity to Community Directives 006//CE Low Voltage Directive 006//CE Machinery Directive EN 600- Safety of machinery - Electrical equipment of machines EN 600- Safety of machinery - Electrical equipment of machines - Requirements for hoisting machines Conformity to CE Standards EN 60- Low-voltage switchgear and controlgear EN 60-- Low-voltage switchgear and controlgear - Control circuit devices and switching elements - Electromechanical control circuit devices EN 60 Degrees of protection provided by enclosures Conformity to culus Standards BGV C Markings and homologations CSA-C. No - Industrial Control Equipment UL 08 Industrial Control Equipment Regulations for the prevention of accidents BGV C (only for Germany) Version IP or IP6: C Version IP 66/IP 6/IP 6K: C GEnERAl technical SpECiFiCAtiOnS Ambient temperature Storage -0 C/+80 C Operational -0 C/+80 C IP IP protection degree IP 6 IP 66/IP 6/IP 6K NEMA protection degree Type (version IP 66/IP 6/IP 6K) Insulation category Maximum rotation speed Cable entry Class II 800 rev./min. Cable clamp M6

technical SpECiFiCAtiOnS OF the microswitches FOR AuxiliARy COntROl BASE Code PRSL000XX PRSL00XX Utilisation category AC Rated operational voltage 0 Vac Rated operational current A Rated thermal current 0 A Rated insulation voltage 00 Vac Mechanical life x0 6 operations Connections 6. mm Faston taps Screw-type terminals Wires - x0.mm, x. mm, x. mm Tightening torque - 0. Nm Microswitch type Contacts Single break, snap action NO+NC change-over contacts (All NC contacts are of the positive opening operation type ) Scheme Markings and homologations C X technical SpECiFiCAtiOnS OF the microswitches FOR DiRECt COntROl Code PRSL0PI Utilisation category AC Rated operational current 00 Vac Rated operational voltage 0 A Rated thermal current 0 A Rated insulation voltage 660 Vac Mechanical life x0 6 operations Connections Screw-type terminals Wires x. mm, x. mm Tightening torque 0.8 Nm Microswitch type Contacts Two-pole NC (All NC contacts are of the positive opening operation type ) Scheme Markings and homologations C

OvERAll DimEnSiOnS (mm) Limit switches with sets of or 6 PRSL000XX/PRSL00XX switches and with sets of PRSL0PI switches have a special cover: overall dimensions and code numbers are available on request. ip or ip 6 * PRSL000XX / PRSL00XX switches or PRSL0PI switch ( ) / PRSL000XX / PRSL00XX switches 6 8 Ø0 Ø0. 0 06. * 8. () 8 Ø8h8 8.. 8 ip 66 / ip 6 / ip 6K * / PRSL000XX / PRSL00XX switches or PRSL0PI switch ( ) PRSL000XX / PRSL00XX switches 6 8 Ø0 Ø0. 06. * 8 (0.) 8 Ø8h8 8. 0. 8

IP or IP 6 with lange * PRSL000XX / PRSL00XX switches or PRSL0PI switch ( ) / PRSL000XX / PRSL00XX switches 0 0.. * 8. () * 0. () 0. 6 8 8 Ø8h8 Ø0. Ø 8.. 8 0 0 0. Ø6. IP 66 / IP 6 / IP 6K with lange * - PRSL000XX / PRSL00XX switches or PRSL0PI switch ( ) PRSL000XX / PRSL00XX switches 6 8 8 0.. * 8 (0.) * (6.) 0. Ø8h8 Ø0. Ø 8.. 0 8. 0 0. Ø6.

ExplODED DRAwinG 0 PRSL000XX PRSL00XX 6 PRSL0PI 8 6 0 8 0 6 8 6

StAnDARD limit SwitChES BASE Standard limit switches are equipped with NO+NC change-over switches for auxiliary control PRSL000XX cams PRSL0PI. and Rated revolution ratio Real revolution ratio No. of cams and switches IP C IP 6 C IP 66 / IP 6 / IP 6K C : :.8 :0 :0. : :.6 :0 :0 : : :00 :0. :0 :8.0 PFAA0000 PFA6A0000 PFA06A0000 PFAA0000 PFA6A0000 PFA06A0000 PFAA0000 PFA6A0000 PFA06A0000 PFAA00000 PFA6A00000 PFA06A00000 PFAA00000 PFA6A00000 PFA06A00000 PFAA00000 PFA6A00000 PFA06A00000 PFAA0000 PFA6A0000 PFA06A0000 PFAA0000 PFA6A0000 PFA06A0000 PFAA0000 PFA6A00006 PFA06A0000 PFAA00000 PFA6A00000 PFA06A00000 PFAA00000 PFA6A00000 PFA06A00000 PFAA00000 PFA6A00000 PFA06A00000 PFAA0000 PFA6A0000 PFA06A0000 PFAA0000 PFA6A0000 PFA06A0000 PFAA0000 PFA6A0000 PFA06A0000 PFAA0000 PFA6A0000 PFA06A0000 PFAA0000 PFA6A0000 PFA06A0000 PFAA0000 PFA6A0000 PFA06A0000 PFAA0800 PFA6A0800 PFA06A0800 PFAA0800 PFA6A0800 PFA06A0800 PFAA0800 PFA6A0800 PFA06A0800

ASSEmBly DRAwinG A A A A A A6 A A8 A A A0 A A A A A6 A A8 8

COmpOnEntS BASE Standard cam sets Ref. Drawing No. and type of cams No. and type of switches Code A cam A PRSL0PI switch PRFC00PE A6 A cams A PRSL000XX switches PRFC0008PEC cams C PRSL000XX switches PRFC000PEC cams A PRSL000XX switches PRFC000PEC cams C PRSL000XX switches PRFC0006PEC A8 cams A PRSL000XX switches PRFC00PEC cams C PRSL000XX switches PRFC08PEC Other sets with /// or 6 switches PRSL000XX/PRSL00XX or with or switches PRSL0PI are available on request. Cam reference chart Cam Switching angle Code A point 0. ±0. PRSL0PI B 0 points.0 ±0. PRSLPI C 60 sector 8.0 ±0. PRSLPI E 80 sector. ±0. PRSLPI H sector.0 ±0. PRSLPI Accessories Ref. Drawing Description Code A Cover with screws for Base IP or IP 6 with switches Cover with screws per Base IP 66/IP 6/ IP 6K with / switches PA000 PA0000 A Cover with screws for Base IP or IP 6 or IP 66/IP 6/IP 6K with / switches PA000 A Gasket for Base IP 6 PRGU08PE A Tightening rubber for Base IP 66/IP 6/IP 6K PRGU00PE A Cover holding wire + screw (bag with 0 pieces) PRSL08PI A0 Cable clamp M6 PRPS006PE

Accessories Ref. Drawing Description Code A Flexible shaft ALLF0000 A Standard shaft ALLR0000 A Bush Ø 8 to Ø for pinion gear/coupling PRTO0PE A Flange PRTO00PE A Pinion gear See pinion gear tables A6 Coupling with pin PRSL08PI A Male coupling with pin PRSL0PI A8 Female coupling with pin PRSL00PI 0

Moulded pinion gears BASE S Legend Z Number of teeth ØDi L ØD M Dp De Module Primitive diameter External diameter Di Internal diameter ØD ØD a Addendum ØDe x d Alpha Dedendum Pressure angle S S Code Z M Dp De Di a d S Alpha D D D S S L PRSL0PI 8.0 0.00.00..0.. 0.00 8.00.0.00 8.00 8.00.00 PRSL0PI 8 0.00 60.00 00.00.0 0.00.0. 0.00.00.00.00.00 0.00.00 PRSL06PI.0.0.0 6..0.. 0.00 8.00.0.0 8.00 8.00.00 PRSL06PI.0.0 8.0.0.0.0. 0.00 8.00.0.00 8.00 8.00.00 PRSL08PI.00.00 6.00 6.00.0.0. 0.00 8.00.0 6.00 8.00 8.00.00 PRSL068PI 0.00 0.00 6.00.00.00.. 0.00 8.00.0.00 8.00 8.00.00 PRSL0PI 0.00 0.00.00.00.00.00 8.8 0.00.00.00.00.00 0.00.00 PRSL0PI 0,00 0,00 68,00 0,,00 6,8, 0,00,00,00,60,00 0,00,00 PRSL0PI 0 6.00 60.00.00.6 6.00 8.6. 0.00.00.00.00.00 0.00.00 PRSL0PI 6.00 66.00 8.00.6 6.00.0. 0.00.00.00.00.00 8.00.00 PRSL06PI.00 60.00 0.00 8.0.00.8.8 0.00.00.00 0.00.00 8.00.00 PRSL08PI 8.00 6.00.00.8 8.00.6.6 0.00.00.0.0.0 0.00.00 PRSL0PI 0.00 0.00 0.00 6.6 0.00.6. 0.00.00.00.00.0 0.00.00 PRSL0PI.00.00 68.00 6.00.00.00 8.8 0.00.00.00.00.00 0.00.00 Measuring unit: mm.

Waterjet cut pinion gears ØDe 0 Legend Z Number of teeth M Module Dp De Primitive diameter External diameter Di Internal diameter 6 a d Addendum Dedendum ØDi Alpha Pressure angle Code Z M Dp De Di a d Alpha PRSL08PI 8 8.00.00 80.00 0.00 8.00.00 0.00 PRSL08PI 8.00.00 0.00 6.00.00 8.00 0.00 PRSL0PI 0.00 0.00 0.00 66.6 0.00.6 0.00 PRSL08PI 6.00.00 6.00 06.6 6.00 8.6 0.00 PRSL08PI 8.00 6.00 8.00 0.00 8.00.00 0.00 PRSL08PI 0.00 80.00 0.00. 0.00. 0.00 PRSL08PI.00 6.00 6.00 60.00.00 8.00 0.00 PRSL086PI 0 0.00 00.00 0.00 6.6 0.00.6 0.00 PRSL0PI 0 8.00 80.00 6.00 8.00 8.00.00 0.00 PRSL00PI 0.00 0.00 6.00 68..00. 0.00 PRSL086PI 0.00 0.00 88.00 8.,00.00 8.00 0.00 PRSL086PI.00.00 6.00 0.00.00.00 0.00 PRSL08PI 8.00 8.00.00 6.00 8.00.00 0.00 PRSL0PI 0.00 0.00 60.00.6 0.00. 0.00 PRSL08PI.00 6.00.00 0.00.00 0.00 0.00 PRSL086PI.00 68.00 6.00.00.00.0 0.00 PRSL08PI 6.00.00.00.6 6.00 8.6 0.00 PRSL0PI 8.00 6.00.00.88 8.00.06 0.00 PRSL08PI 0.00 0.00 80.00. 0.00. 0.00 PRSL088PI.00 88.00 6.00.00.00 8.00 0.00 PRSL0860PI 6.00 8.00 0.00 6.00 6.00.0 0.00 PRSL08PI.00 6.00 8. 6,00,,00 0,00 PRSL088PI 6.00 08.00 0.00 0,6 6,00 8,66 0,00 PRSL6PI 6.00 8.00 6.00 6.00 6,00,0 0,00 PRSL086PI 0.00 0.00 6.00.00.00.0 0.00 PRSL086PI 6.00.00 6.00 86.6 6.00 8.6 0.00 PRSL0PI 8.00.00 88.00 0.00 8.00.00 0.00 PRSL088PI 0.00 80.00 0.00. 0.00. 0.00 PRSL088PI 8.00 0.00 06.00 8.00 8.00.00 0.00 PRSL08PI 6 0.00 0.00 60.00. 0.00. 0.00 PRSL0PI 0.00 0.00 0.00.00 0.00.0.8 PRSL0PI.00 8.00 66.00 0.00.00.0.8 PRSL08PI 0 6.00 0.00.00 0.00 6.00.0.8 PRSL08PI.00.00.00.0.00..8 Measuring unit: mm.

- REquESt FORm FOR non StAnDARD limit SwitCh BASE instructions Revolution ratio 6 version: tick the required version. Standard cam set: write the code of the cam set required. Customized cam set: for non standard cam sets, ill in the scheme choosing the cams and the switches required. In case switch PRSL0PI is required, it is possible to use only one switch. Customized cams are available on request. : :0 : :0 : :00 :0 : Sets with /6 switches PRSL000XX/PRSL00XX and with switches PRSL0PI are available on request. Standard shaft Version with anti-moisture plug: tick when the anti-moisture plug is required. Flexible shaft 6 Cover holding wire: tick when the cover holding wire is required. Revolution ratio: write the required revolution ratio. Male coupling Coupling 8 Shaft: tick the shaft type required. Female coupling Flange 8 Coupling, lange, pinion gear: tick the box when coupling, flange or pinion gear are required. Pinion gear When a standard pinion gear is required, write the code number listed in the pinion gear charts in the catalogue. When a special pinion gear is required, write the number of teeth, the module and the primitive diameter. Pinion gear code Customized pinion gear No. of teeth version IP00 (without cover) C Module Primitive diameter IP C Legend - Standard cam sets IP6 C IP66 / IP6 / IP6K C ATTENTION: Limit switches with anti-moisture plug are not curus certiied.. Special limit switches with -6 switches PRSL000XX/PRSL00XX are not EAC nor curus certiied. All limit switches with switches PRSL0PI are not EAC nor curus certiied. No. & type of switches No. & type of cams Code x PRSL0PI cam A PRFC00PE cams A PRFC0008PEC x PRSL000XX cams C PRFC000PEC cams A PRFC000PEC x PRSL000XX cams C PRFC0006PEC Standard cam set Cam set code x PRSL000XX cams A PRFC00PEC cams C PRFC08PEC Customized cam set Legend - Standard cams Cam Switching angle Code A point 0, ±0, PRSL0PI B 0 points,0 ±0, PRSLPI C 60 sector 8,0 ±0, PRSLPI Cam code Switch code E 80 sector, ±0, PRSLPI H sector,0 ±0, PRSLPI Legend - Switches Auxiliary control Direct control Version with anti-moisture plug PRSL000XX PRSL00XX PRSL0PI NO+NC NO+NC NC Cover holding wire

use AnD maintenance instructions Base rotary limit switch is an electromechanical device for low voltage control circuits (EN 60-, EN 60--) to be used as electrical equipment on machines (EN 600-) in compliance with the fundamental requirements of the Low Voltage Directive 006//CE and of the Machine Directive 006//CE. The limit switch is designed for use in industrial environments under even severe climatic conditions (operational temperature from 0 C to +80 C, suitable for use in tropical environment). The equipment is not suitable for use in environments with potentially explosive atmosphere, corrosive agents or a high percentage of sodium chloride (saline fog). Oils, acids or solvents may damage the equipment; avoid using them for cleaning. Do not connect more than one phase to each switch. Do not oil or grease the control elements or the switches. The installation of the limit switch shall be carried out by expert and trained personnel. Wiring shall be properly done according to the current instructions. Prior to the installation and the maintenance of the limit switch, the main power of the machinery shall be turned off. Steps for the proper installation of the limit switch - Loosen the ixing screw () and remove the cover (.) - Connect the limit switch shaft () to the reduction gear shaft avoiding any misalignment between the two shafts. - Fix the limit switch irmly in place to prevent abnormal vibrations of the equipment during operation; use only the ixing holes on the base () to ix the equipment. - Tighten the cable clamp () into appropriate place. - Insert the cable into the limit switch through the cable clamp (). - Strip the cable to a length suitable for wiring the switches. - Tape the stripped part of the cable. - Clamp the wire into the cable clamp (). - Connect the switches according to the contact scheme printed on the switches or to the wiring scheme on the back of the instructions (use 6. mm Faston taps). - Adjust the operating point of the cams; for proper adjustment, loosen the central screw () of the cam set, adjust the operating point of each single cam by turning its screw (8) (the numbers on the screws refer to the cams counting from bottom to top), then tighten the central screw (). - Insert the free end of the no-drop wire (), if used, into one of the screws (), then close the limit switch using the screws (); check the proper positioning of the rubber (6) in the cover (0) and tighten the screws () with a torque of 80/00 cnm. periodic maintenance steps - Check the proper tightening of the screws () and cover (). - Check the proper tightening of the central screw () holding the cams. - Check the wiring conditions (in particular where wires clamp into the switch). - Check the conditions of the rubber (6) it between the cover () and the base () and check the tightening of the cable clamp () around the cable. - Check that the limit switch enclosure (, ) is not broken. - Check the alignment between the limit switch shaft () and the reduction gear shaft. - Check that the limit switch is properly ixed. - If there is an anti-moisture plug, check its conditions. In case any component of the limit switch is modiied, the validity of the markings and the guarantee on the equipment are annulled. Should any component need replacement, use original spare parts only. TER declines all responsibility for damages caused by the improper use or installation of the equipment.

ip ip 6 6 ip 66/ip 6/ip 6K 6 8 Image for illustrative purpose only. Number and type of cams differ depending on the model.

REmARKS 6