J0NES-BLAIR PAINT MANUFACTURERS OF QUALITY PAINT SINCE 1928 INDUSTRIAL COATINGS (High Performance)

Similar documents
PRETREATMENT TECHNICAL DATA SHEET IRON PHOSPHATE CLEANER COATER / CONVERSION COATING PRODUCT DESCRIPTION

PRETREATMENT TECHNICAL DATA SHEET IRON PHOSPHATE CONVERSION COATING PRODUCT DESCRIPTION

SWARCO LIMBURGER LACKFABRIK GmbH Road Marking Systems. 1-component Afterglow paint system TECHNICAL INFORMATION

AO291 Issue date: Product Data FASSON Transfer Polyimide Matt White TC11 / S8088 / BG50 Wh

Accumulators Virginia KMP Suction Line Accumulators

PRETREATMENT TECHNICAL DATA SHEET MULTIMETAL IRON PHOSPHATE CONVERSION COATING PRODUCT DESCRIPTION

Home, Institutional and Personal Care Solutions. ACUSOL Dispersant Polymers for Household Products and Industrial & Institutional Cleaners

ACRYSOL TT-935 Rheology Modifier

Technical Data Sheet.

ACRYSOL TT-615 Rheology Modifier

Avery Dennison LW Series Retroreflective Window Sticker Film Issued: July 2013

PRODUCT SAFETY SUMMARY (GPS) SODIUM-HYDROXIDE

Making chemistry work for you. ISCATHIX Rheological Additives

PRETREATMENT TECHNICAL DATA SHEET A CHROME-FREE FINAL RINSE PRODUCT DESCRIPTION

L u m b e r M e l a m i n e H a r d w o o d P l y w o o d A r c h i t e c t u r a l P a n e l s C o l o r e d C a u l k P a r t i c l e B o a r d E

Type B xxx/60. Snowplough // USER MANUAL Version 1.0 EN. Art.Nr.:

The Perfect Symmetry of Form and Function

ACRYSOL TT-935 ER Rheology Modifier

SAFETY TRAINING LEAFLET 08 ACETYLENE, CALCIUM CARBIDE, LIME SLUDGE AND PURIFYING MATERIALS

Glycol Ethers for Aqueous Cleaners

Fischer Banjo Weather Station with Thermometer, Hygrometer, Barometer User Manual

Fischer 1508BTH-45 5" Brass Barometer with Temperature & Humidity User Manual

An Introduction to Insulation Resistance Testing

Electrical Double Layer Energy Storage Capacitors Up to 3 V Operating Voltage

Ruggedized Electrical Double Layer Energy Storage Capacitors

PRETREATMENT TECHNICAL DATA SHEET CHROMIUM-FREE ORGANIC PASSIVATING RINSE PRODUCT DESCRIPTION

Ambient Weather WS-152B 6" Contemporary Barometer User Manual

ACRYSOL RM-5000 Rheology Modifier

symphony Reference Electrodes

Ambient Weather WS-228TBH 9" Brushed Aluminum Traditional Barometer with Temperature and Humidity, Radiant Blue User Manual

Fischer Instruments Stainless Steel Barometer User Manual

Medium Pressure Sensor Analog Output

Guide Specifications Section

PRETREATMENT TECHNICAL DATA SHEET CHROMIUM-FREE ORGANIC PASSIVATING RINSE PRODUCT DESCRIPTION

AM 500A 500 WATT AM 1A 1 KILOWATT AM BROADCAST TRANSMITTERS. October, 1999 IM No

To measure ph s in a variety of solutions and mixtures and to account for the results obtained.

Quick Reference. Daily Cleaning Procedures Pages 3-8 Stopping Conditions & Recovery Steps Pages 9-20

AMBERLITE HPR1300 H Ion Exchange Resin

Lab: Detecting ph of Commonly Used Acids and Bases

Fischer Instruments Chrome and Black Wood Base Weather Station with Barometer, Hygrometer, Thermometer and Quartz Clock User Manual

Surface Mount Multilayer Ceramic Chip Capacitors for Ultra Small Commodity Applications

Ambient Weather WS-GL026 Porthole Collection Weather Center with Thermometer, Hygrometer, Barometer User Manual

IR F ( C) ENGLISH INSTRUCTION MANUAL. Thermometer

ACRYSOL TM RM-8WE Rheology Modifier

Ultra-Small Footprint N-Channel FemtoFET MOSFET Test EVM

Small Absolute Pressure Sensor

ACRYSOL RM-725 Rheology Modifier

NANOSTONE Cleaning Guidelines for Spiral E-Coat Elements

ACRYSOL TM RM-8W Rheology Modifier

Table of Contents What is ? The Chemistry of What Does Protect Against? What Does the Package Include? The

Rectifier Diode RR2L4S

Latest generation testo air velocity & IAQ probes with cable handle. Instruction manual

Low Pressure Sensor Amplified Analog Output SM6295-BCM-S

Retroreflective Prismatic License Plate Film

Borchers Rheological Additives for waterborne coating systems. Borchi Gel

Surface Mount Multilayer Ceramic Chip Capacitors with Integrated Resistor for High Pulse Current Applications

Small Gage Pressure Sensor

Radiation Curable Additives Enabling Excellent Paint Surfaces

Melton Series. Owners Manual. Lab Centrifuge. Model # s A C, A C, B C, B C, C C, C C, D C, D C

Avery Dennison LV-0700 Series Retroreflective Validation Decal Film Issued: July 2013

We add quality CHEMICAL SPECIALTIES

PFA HP Plus GBK Lining Sheet

Discrete Semiconductor Devices

POLYPHOSPHORIC ACID ASSAY

6. Common Laboratory Techniques

Global Product Strategy (GPS) Safety Summary. Tetrahydrofuran

PRODUCT INFORMATION LEWATIT S 4328

N) manual. Biomaster Operating manual

CHEMICAL SAFETY TRAINING LEADER GUIDE. Chemical Safety Training Leader Workbook 1

Safety of the UV/EB Curing Process

OEM Silicon Pressure Die

Power Resistor for Mounting onto a Heatsink Thick Film Technology

3. The provisions of this rule shall become effective on December 1, 1996.

Power Resistor for Mounting onto a Heatsink Thick Film Technology

Small, Gauge Pressure Sensor

CRAIG MANUFACTURING LTD. 96 McLean Ave. Hartland, New Brunswick CANADA E7P 2K5

Power Resistor for Mounting onto a Heatsink Thick Film Technology

Methyl isobutyl ketone

Aluminum Electrolytic Capacitors Axial Miniature, Long-Life

Surface Mount Multilayer Ceramic Chip Capacitors Prohibit Surface Arc-Over in High-Voltage Applications

Surface Mount Multilayer Ceramic Chip Capacitor Solutions for High Voltage Applications

Rectifying Diode RR2LAM6STF

Avery Dennison L-3050 Series Retroreflective License Plate Film September 2013 Revision 2

Manual Dew point scanner PCE-DPT 1

Vinmetrica Deluxe Lab Accessory Kit User Manual

Press Felt Optimization

Sealeze TM SSG515AT2D Static Dissipation Brush Performance in an Operational Environment

Conductive Polymer Aluminum Capacitors SMD (Chip), Low Impedance

SMD Aluminum Solid Capacitors with Conductive Polymer

Must Read Before Installation TadPoleTM Safety and Warnings

GPS Safety Summary Acetic Acid

Temperature Profile for 36 Marker Spheres on 3M 788 ACCR Conductor 3M Company

TOSHIBA Field Effect Transistor Silicon N Channel MOS Type SSM6N15FE

Bindzil CC in the coating industry. Silane modified colloidal silica dispersions functions and applications

Bindzil and Levasil product guide. Colloidal silica dispersions functions and applications

GUIDELINES FOR THE SAFE USE OF PYROPHORIC LIQUID REAGENTS

Ambient Weather DHR70B-BRASS Handheld Fishing Barometer User Manual

Surface Mount Multilayer Ceramic Capacitors for Pulse Current Applications

THREE HOLE SPLICE CLEVIS FOR B52 Standard finishes: ZN, GRN Wt./C 126 Lbs. (57.1 kg)

Protective Coatings: Non-lead orange paint RAL red (optional) non-lead paint Hot dipped galvanized conforming to ASTM A-153.

Transcription:

1 J0NES-BLAIR PAINT MANUFACTURERS OF QUALITY PAINT SINCE 1928 INDUSTRIAL COATINGS (High Performance) TYPE OF COATINGS for CLARK SERVICE STATION CANOPY UNDER-DECK CEILINGS. FEATURES OUTSTANDING ADHESION WITH SPECIFIED PRIMER AND SUPERIOR COVERAGE WITH TOPCOAT OF #45081/99951 ACRYLITHANE WHITE FINISH Product: Acrylithane HS2 Acrylic Urethane Paint System for Repainting Factory Finished or PREVIOUSLY PAINTED CANOPY UNDER-DECK CEILINGS OF Baked Enamel Finishes & Power Washing Specifications FIELD APPLICATION INSTRUCTIONS FROM JONES-BLAIR PAINT COMPANY Direct: 1(214) 353-1600 Nat l Watts: 1 (800) 527-7540 Customer Service/Sales/Ordering Fax Line: 1 (800) 325-6321 E-mail Address: sales@jones-blair.com National Order Placement Personnel ELIDA RODRIQUEZ erodriquez@jones-blair.com Technical Information Kristal Bluemer National Sales Manager Cell: 214-676-8542 Email: kbluemer@jones-blair.com The information data and suggestions contained herein are believed to be reliable based upon our knowledge and experience; however, it is expressly declared that Seller does not guarantee the result to be obtained in Buyers processes. SELLER HEREBY EXPRESSLY DISCLAIMS ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE AND/OR ANY OTHER WARRANTY EXPRESSED OR IMPLIED as to any and all products and or suggestions described herein whether such products are used along or in combination with other materials. Buyer must make its own determination of the suitability of any product for its use and the completeness of any information contained herein. Nothing contained herein shall be construed to constitute inducement or recommendation to practice any invention covered by any patent without authority from the owner of the patent. Jones-Blair Company 2005/2006/2014

2 TECHNICAL INFORMATION FOR USING JONES-BLAIR ACRYLITHANE HS2 SYSTEM (When using in California, order HS4 primer & finish to meet VOC requirements) Mixing, Thinning, and Application Instruction Jones-Blair Acrylithane HS2 (high solids) is a two component product and must be mixed. A 3:1 mixing ratio is required. Mix one 3/4 gallon of Acrylithane HS2 base material with one (1) quart of #99951 Acrylithane Catalyst. Up to one (1) quart of #21092 thinner may be added per gallon of mixed paint. Thinning is recommended for spray application. For brush and roller application, thinning is not normally required. Apply Acrylithane only to thoroughly dry surfaces. When applying at temperatures exceeding 85 o F, addition of as much as three fluid ounces (about onefifth pint) of #21093 drying retardant per gallon of Acrylithane is recommended. Use of drying retardant prevents dry spray and undesired fast drying on the surface being covered as well as on brushes and rollers. For application in temperatures between 35 and 55 o F, it is recommended that 1/4-ounce (2 capfuls) of #99011Accelerator be added per catalyzed gallon of Acrylithane. SURFACE PREPARATION FOR FACTORY FINISHED or PREVIOUS COATS OF PAINT. Surfaces must be clean and free from oil, grease, wax or other foreign matter. Clean any chalky surfaces thoroughly with detergent and water then rinse with clean water. MILDEW REMOVAL Remove any mildew (wearing protective clothing, gloves and safety goggles) by washing with a solution of household bleach, water and household detergent (3 quarts water plus 1 quart bleach plus 1 cup detergent by volume per gallon). Do not add ammonia to the mixture. Rinse the washed surface thoroughly with clean water and allow to dry before priming or finishing. It is recommended that all surfaces be power washed and allowed to dry thoroughly before priming. A Power Washing Specification follows this document. Glossy surfaces must be dulled by sanding. Repair or replace unsuitable or damaged deck surfaces. PRIMING Apply one coat of Jones-Blair #33010 White Ureprime Epoxy Urethane Primer by roll, brush or spray to achieve maximum adhesion. #33010 Ureprime is a two component system and must be mixed. Mix at a 3:1 ratio with #99951 Catalyst (Activator). Order one quart of #99951 for each short filled gallon of #33010 Ureprime. Thin sparingly or as needed with #21092 Acrylithane Thinner for roller or brush application. (In California, use 33014 Ureprime HS4. Mix full gallon of 33014 with one quart of #99951 Catalyst)

3 FINISH COATS Apply ONE-TWO finish coats to hide of Jones-Blair Acrylithane HS2 Acrylic Urethane #45081 Deck White for desired appearance. Acrylithane is a two component product and must be mixed.. #33010 Ureprime is also two components and is mixed with one quart of #99951 Catalyst. Order one quart of #99951 catalyst for each short filled gallon of Acrylithane HS2 Urethane. (When using in California, order HS4 primer & finish to meet VOC requirements) FOLLOW MANUFACTUERS SPECIFICATIONS FOR APPLICATION EQUIPMENT. Recommended Application Equipment Associated Sundry Products for Proper Application: To help ensure ease of application and uniformity of finish, the following products are recommended. For your convenience, these can be ordered and shipped through customer service at the same time you order Acrylithane HS3. No thinning normally required. If applying on air or surface temperatures above 85 o F, up to three ounces of JB #21093 Drying Retarder may be used to slow drying. Clean tools with JB #21092 Reducer. JB Item # Description For smooth surfaces: 1/4 nap mohair roller cover or 3/8 th inch 86704 1 size Elastic Vinyl Car Cover Spraying Equipment Model Gun Air Cap Fluid Atomizing Tip Pressure DeVilbiss MBC 510 # 704 FX 25-60 PSI Binks #18 63PB 66 25-60 PSI Reduction: Up to 25% with JB #21092 Reducer to mixed gallon. Up to six ounces of JB #21093 Retarder may be added to prevent fast dry or cob webbing in temperatures above 85 o F. Clean-up: Clean equipment IMMEDIATELY after using. Use JB #21092 or 21102 Reducer for cleaning. Airless Spray: Pump Ratio 30:1-35:1 Pressure 1800-2600 Reduction and Clean-up: Same as for Air Spray. Fluid Tip.011 -.015 Fluid

4 JONES-BLAIR Technical Data Sheet MANUFACTURERS OF QUALITY PAINT SINCE 1928 Protective Coatings DEW POINT OF MOIST AIR It is generally not recommended to apply Jones-Blair Acrylithane HS3 Aliphatic Polyurethane Enamel or any Polyurethane Enamel any time the substrate (surface) temperature is within 5 0 F of the dew point. This chart illustrates how to calculate the dew point: DEW POINT OF MOIST AIR Ambient Air Temperature Relative Humidity 20 0 F -7 0 F 30 0 F -1 0 C 40 0 F 4 0 C 50 0 F 10 0 C 60 0 F 10 0 C 70 0 F 21 0 C 80 0 F 27 0 C 90 0 F 32 0 C 100 0 F 38 0 C 110 0 F 43 0 C 120 0 F 40 0 C 90 18 0 F -8 0 C 28 0 F -2 0 C 37 0 F 3 0 C 47 0 F 8 0 C 57 0 F 14 0 C 67 0 F 19 0 C 77 0 F 25 0 C 87 0 F 31 0 C 97 0 F 36 0 C 107 0 F 42 0 C 1 17 0 F 47 0 C 85 17 0 F -8 0 C 26 0 F -3 o C 36 0 F 2 0 C 45 0 F 7 0 C 55 0 F 13 0 C 65 0 F 18 0 C 75 0 F 24 0 C 84 0 F 29 0 C 95 0 F 35 0 C 104 0 F 40 0 C 113 0 F 45 0 C 80 16 0 F -9 0 C 25 0 F -4 0 C 34 0 F 1 0 C 44 0 F 7 0 C 54 0 F 12 0 C 63 0 F 17 0 C 73 0 F 23 0 C 82 0 F 28 0 C 93 0 F 34 0 C 102 0 F 39 0 C 110 0 F 43 0 C 75 15 0 F -9 0 C 24 0 F -4 0 C 33 0 F 1 0 C 42 0 F 6 0 C 520F 11 0 C 62 0 F 17 0 C 71 0 F 22 0 C 80 0 F 27 0 C 91 0 F 33 0 C 100 0 F 38 0 C 106 0 F 42 0 C 70 13 0 F -11 0 C 22 0 F -8 0 C 31 0 F -1 0 C 40 0 F 4 0 C 50 0 F 10 0 C 60 0 F 16 0 C 68 0 F 20 0 C 78 0 F 26 0 C 88 0 F 31 0 C 96 0 F 36 0 C 105 0 F 41 0 C 65 12 0 F -11 0 C 20 0 F -7 0 C 29 0 F -2 0 C 36 0 F 3 0 C 47 0 F 8 0 C 57 0 F 14 0 C 66 0 F 19 0 C 76 0 F 24 0 C 85 0 F 29 0 C 93 0 F 34 0 C 103 0 F 39 0 C 60 11 0 F -12 0 C 19 0 F -7 0 C 27 0 F -3 0 C 36 0 F 2 0 C 45 0 F 7 0 C 55 0 F 13 0 C 64 0 F 18 0 C 73 0 F 23 0 C 83 0 F 26 0 C 92 0 F 33 0 C 101 0 F 38 0 C 55 9 0 F -13 0 C 17 0 F -8 0 C 25 0 F -4 0 C 34 0 F 1 0 C 43 0 F 6 0 C 53 0 F 12 0 C 61 0 F 16 0 C 70 0 F 21 0 C 80 0 F 27 0 C 89 0 F 32 0 C 96 0 F 37 0 C 50 6 0 F -14 0 C 15 0 F -9 0 C 23 0 F -5 0 C 31 0 F -1 0 C 40 0 F 4 0 C 50 0 F 10 0 C 59 0 F 15 0 C 67 0 F 19 0 C 77 0 F 25 0 C 86 0 F 30 0 C 94 0 F 34 0 C 45 4 0 F -16 0 C 13 0 F -11 0 C 21 0 F -6 0 C 29 0 F -2 0 C 37 0 F 3 0 C 47 0 F 8 0 C 58 0 F 13 0 C 64 0 F 18 0 C 73 0 F 23 0 C 82 0 F 28 0 C 91 0 F 33 0 C 40 1 0 F -17 0 C 11 0 F -12 0 C 18 0 F -8 0 C 26 0 F -3 0 C 35 0 F 2 0 C 43 0 F 6 0 C 52 0 F 11 0 C 61 0 F 16 0 C 69 0 F 21 0 C 78 0 F 28 0 C 87 0 F 31 0 C 35-2 0 F -19 0 C 8 0 F -13 0 C 16 0 F -9 0 C 23 0 F -5 0 C 31 0 F -1 0 C 40 0 F 4 0 C 48 0 F 9 0 C 57 0 F 14 0 C 65 0 F 18 0 C 74 0 F 23 0 C 83 0 F 28 0 C 30-6 0 F -20 0 C 4 0 F -16 0 C 13 0 F -11 0 C 20 0 F -7 0 C 28 0 F -2 0 C 36 0 F 2 0 C 44 F 7 0 C 52 0 F 11 0 C 61 0 F 16 0 C 69 0 F 21 0 C 77 0 F 25 0 C Example: If air temperature is 70 0 F and relative humidity is 65 0 F, the dew point is 57 0 F The information data and suggestions contained herein are believed to be reliable based upon our knowledge and experience; however, it is expressly declared that Seller does not guarantee the result to be obtained in Buyer s processes. SELLER HEREBY EXPRESSLY DISCLAIMS ANY IMPLIED W ARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE AND/OR ANY OTHER W ARRANTY EXPRESSED OR IMPLIED as to any and all products and/or suggestions described herein whether such products are used along or in combination with other materials. Buyer must make its own determination of the suitability of any product for its use and the completeness of any information contained herein. Nothing contained herein shall be construed to constitute inducement or recommendation to practice any invention covered by any patent without authority from the Owner of the patent. Jones-Blair Company Dallas, TX 75235

6 Jones-Blair Company Power Washing Specifications Power washing is required for all canopy decks and is recommended for fascia surfaces where dirt or other contaminants may collect from the environment and if repainting is required. Buildings and other structures should also be power washed if they are to be painted. Equipment Power washing pumps should be capable of generating 3,000 to 4,000 psi and deliver 6-10 gpm of wash/rinse water. Fan type spray tips give varying spray angles. Fan tips are considered to be "scrapers" and/or "pushers". The spray tips used should be selected for this program should be based on the area and surface to be cleaned. Do not use a round tip or what is commonly referred to as a "shotgun", point tip or "0" tip. Round tips used with high pressure may result in surface damage on wood, metal or masonry. This type of spray tip is considered to be a "cutter". High flow rate/low pressure machines will generally clean better than a low flow rate/high pressure machine. Consult SSPC-SP12/NACE No. 5 "Surface Preparation and Cleaning of Steel and Other Hard Materials by High and Ultrahigh Pressure Water Jetting Prior to Recoating" for additional information. Cleaning Agents There is a number of cleaning agents or detergents that can be used in conjunction with pressure washers. Cleaning agents can dramatically improve cleaning efforts. A solution of house hold bleach and water should be used to kill mildew and mold followed by rinsing the surface. Consult the manufacturer's recommendations based on the type of surfaces to be cleaned. Also consider health, safety and environmental issues when selecting the appropriate cleaner. Do not use any solutions that are caustic soda (causes pitting of aluminum), chlorine (discolors all metals), strong alkaline (will damage painted surfaces) or acid type cleaners that will deteriorate galvanized metal or etch glass. The best cleaning agent for common soil types to remove grease, oil and dirt is a medium duty alkaline (ph of 8 to 12) at about 3% concentration by volume for painted metal, wood, and galvanized aluminum. Regardless of the cleaning agents used, the surfaces cleaned must be thoroughly rinsed with clear water to insure that the cleaning solution has been removed. Failure to thoroughly remove the cleaning agent could result in poor paint adhesion when the surfaces are painted. All power washed surfaces must be dry before painting. Preparation and Power Washing Cover all surfaces that might be damaged by power washing such as dispensers, automobiles, light fixtures, cameras, foliage, etc. All surfaces should be scrubbed to remove contaminants. Heavily stained areas may need pre-treatment. A minimum of two passes is required: one with cleaning solution and the final rinse. All standing water should be removed from the site to ensure that there are no remaining chemicals and to avoid spotting. Reclamation Contractor is expected to comply with all regulations regarding the disposal of wash and rinse water. Local or state regulations may not permit these waters into the site storm drains, or, to be allowed to run off site. For those areas that do have special reclamation requirements, contact the Project Manager. 2003 Jones-Blair Company