Electronic skin replaces volunteer experiments

Similar documents
Optimization of Skin Impedance Sensor Design with Finite Element Simulations

2/25/2014. Circuits. Properties of a Current. Conservation of Current. Definition of a Current A. I A > I B > I C B. I B > I A C. I C D. I A E.

mith College Computer Science CSC270 Spring 16 Circuits and Systems Lecture Notes Week 3 Dominique Thiébaut

Study of Specific Absorption Rate (SAR) in the human head by metamaterial attachment

Dielectric properties of biological tissues at frequencies below 1 MHz. Azadeh Peyman

Substrate Selection Can Simplify Thermal Management

Chapter 2. Engr228 Circuit Analysis. Dr Curtis Nelson

The Ordering Code for various standard model Recorders with an AC supply and without any additional options are as follows:

Chapter 13. Capacitors

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER

Modeling Motor Responses of Paraplegics under Epidural Spinal Cord Stimulation: Computational Modeling Technical Report

1) Thermo couple sensor

An Autonomous Nonvolatile Memory Latch

PHYSICS QUESTION PAPER CLASS-XII

Science 30 Unit C Review Outline GCCHS. Negatively charged Positively charged Coulomb Conductor Electric potential difference

Designing Information Devices and Systems I Fall 2018 Lecture Notes Note Introduction: Op-amps in Negative Feedback

ES250: Electrical Science. HW1: Electric Circuit Variables, Elements and Kirchhoff s Laws

An Electronic Thermal Transducer

Electricity. From the word Elektron Greek for amber

Thermo-elastic Response of Cutaneous and Subcutaneous Tissues to Noninvasive Radiofrequency Heating

White Paper. Capacitive Coupling with Unshielded Laparoscopic Electrodes. By Kurt Aronow, P.E. July 2007

Operational Amplifiers

From this analogy you can deduce some rules that you should keep in mind during all your electronics work:

EMF Energy Absorption Mechanisms in the mmw Frequency Range. Andreas Christ

Chapter 22: Current and Resistance Solutions

RC Circuit Lab - Discovery PSI Physics Capacitors and Resistors

16.1 Electrical Current

PHY3901 PHY3905. Hall effect and semiconductors Laboratory protocol

ISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER

ESE319 Introduction to Microelectronics. Output Stages

Technical Notes. Introduction. PCB (printed circuit board) Design. Issue 1 January 2010

SECTION 3 BASIC AUTOMATIC CONTROLS UNIT 12 BASIC ELECTRICITY AND MAGNETISM

Operational Field Coupled ESD Susceptibility of Magnetic Sensor IC s in Automotive Applications

BENG 186B Winter 2013 Quiz 2. February 15, NAME (Last, First): This quiz is closed book and closed notes. You may use a calculator for algebra.

THREE-PHASE CIRCUITS

Does a standalone, cold (low-thermal-noise), linear resistor exist without cooling?

Midterm Exam (closed book/notes) Tuesday, February 23, 2010

A.M. WEDNESDAY, 13 May minutes

EMF exposure of the skin at the mmw

CHAPTER.4: Transistor at low frequencies

ESE319 Introduction to Microelectronics Common Emitter BJT Amplifier

NATIONAL CERTIFICATE (VOCATIONAL) NQF LEVEL 2 SUPPLEMENTARY EXAMINATION

Old Dominion University Physics 112N/227N/232N Lab Manual, 13 th Edition

Excerpt from the Proceedings of the COMSOL Conference 2009 Milan

The dielectric properties of biological tissues: III. Parametric models for the dielectric spectrum

PHYSICS ASSIGNMENT ES/CE/MAG. Class XII

SOME USEFUL NETWORK THEOREMS

LED s and R e sist or s

Ohm's Law and Resistance

ON USING SINGLE FREQUENCY ELECTRICAL MEASUREMENTS FOR SKIN HYDRATION ASSESSMENT

EE301 RESISTANCE AND OHM S LAW

I PUC ELECTRONICS MODEL QUESTION PAPER -1 ( For new syllabus 2013)

ELECTROMAGNETIC MODELING OF VIRTUAL HUMANS TO DETERMINE HEART CURRENT FACTORS

M. C. Escher: Waterfall. 18/9/2015 [tsl425 1/29]

November MVP R&S FSW Analyzer. Vol. 54 No. 11. Founded in mwjournal.com

Resistivity and Temperature Coefficients (at 20 C)

Investigation of SLF-EMF effects on Human Body using Computer Simulation Technology

Cut-and-Paste Organic FET Customized ICs for Application to Artificial Skin

BE 3600 BIOMEDICAL INSTRUMENTATION (LAB) - WEEK 2

Kirchhoff's Laws and Circuit Analysis (EC 2)

TE 75R RESEARCH RUBBER FRICTION TEST MACHINE

Chapter 9 Bipolar Junction Transistor

Homework Assignment 09

Designing a Thermostat Worksheet

4 Electric circuits. Serial and parallel resistors V 3 V 2 V Serial connection of resistors:

Designing Information Devices and Systems I Spring 2015 Note 11

The design and operational theory of ph electrodes is a very complex subject, explored only briefly here. What is important to understand is that thes

EE 434 Lecture 13. Basic Semiconductor Processes Devices in Semiconductor Processes

Conventional Paper I-2010

What is electricity? Charges that could be either positive or negative and that they could be transferred from one object to another.

PHYS 1444 Section 004 Lecture #10

ECE-342 Test 3: Nov 30, :00-8:00, Closed Book. Name : Solution

Development of a Thermal Voltage Converter with Calculable High-Frequency Characteristics

Microelectronic Circuit Design 4th Edition Errata - Updated 4/4/14

B THE CAPACITOR. Theory

Final Exam: 11 May 2001, Friday

Sensors and Actuators Sensors Physics

55:041 Electronic Circuits The University of Iowa Fall Final Exam

Computation of Electromagnetic Energy Absorption in the Human Body Tissues by High Frequency Structure Simulator

1 Force Sensing. Lecture Notes. 1.1 Load Cell. 1.2 Stress and Strain

EE Branch GATE Paper 2010

ERROR SOURCE IDENTIFICATION AND STABILITY TEST OF A PRECISION CAPACITANCE MEASUREMENT SYSTEM

ELG4112. Electromechanical Systems and Mechatronics

Nuclear Medicine RADIOPHARMACEUTICAL CHEMISTRY

4.2.1 Current, potential difference and resistance

Estimation of EUROP- Conformation and Fatness of Beef Carcasses by Bioelectrical Impedance Analysis.

Chapter 2. Chapter 2

Experiment 5: Thermocouples (tbc 1/14/2007, revised 3/16/2007, 3/22,2007, 2/23/2009, 3/13/2011)

E40M Review - Part 1

1 Written and composed by: Prof. Muhammad Ali Malik (M. Phil. Physics), Govt. Degree College, Naushera

They keep the voltage the same and use this circuit to measure the current. Variable resistor. Reading on ammeter in amps

A two-port network is an electrical network with two separate ports

Level 1 Physics, 2010

Problem info Geometry model Labelled Objects Results Nonlinear dependencies

Electron Theory. Elements of an Atom

Ph February, Kirchhoff's Rules Author: John Adams, I. Theory

Switch or amplifies f. Capacitor i. Capacitance is measured in micro/pico farads ii. Filters frequencies iii. Stores electrical energy

Learning Material Ver 1.2

Piezoelectric Resonators ME 2082

CARLETON UNIVERSITY. FINAL EXAMINATION December DURATION 3 HOURS No. of Students 130

Transcription:

Modelling in Medicine and Biology VI 571 Electronic skin replaces volunteer experiments N. Nessler, W. Reischer & M. Salchner Institute for Applied Physics, University of Innsbruck, Innsbruck, Austria Abstract Neutral electrodes (grounding plates used in electrosurgical operations) were tested with thermo cameras in volunteer experiments. These experiments are difficult to perform and expensive. A new test device swarotest with a measuring board electronic skin simulates the relevant electrical features of human skin to replace volunteer experiments. This device consists of a three dimensional resistor network representing the electric features of the skin and muscle tissue, and a temperature sensing array (one transistor for each cm²) to measure the resultant temperature increase after a standardized current load (700 ma hf current during 60 s, proposed in the relevant AAMI HF-18 standard). The comparison of test results with thermo camera images of volunteer experiments showed a sufficient coincidence, which proves the applicability of this test device to replace volunteer experiments. Keywords: electronic skin, electrosurgery, neutral electrode. 1 Introduction Neutral electrodes (dispersive electrodes, grounding plates) are safety relevant accessories in electrosurgery and must be tested according to AAMI HF 18 standard. A neutral electrode in contradiction to the active electrode (electrical knife) must not heat the patient s skin in excess of 6 C during the hf-current pass. One test method is a volunteer experiment under standardized conditions (AAMI) with a thermo camera to measure the temperature increase on the skin under the neutral electrode. This method is laborious (10 volunteers for one significant test!), time consuming and expensive (thermo camera, clinical environment) and cannot be used routinely for quality tests. The result of a typical volunteer experiment is shown in fig. 1. As usual the higher temperatures are displayed in yellow to red, cooler sites are green to blue.

572 Modelling in Medicine and Biology VI An alternative is a suitable structured surrogate medium (AAMI) which simulates the electrical features of the patient s skin found in electrosurgery. The solution is an electronic simulation of the skin the electronic skin. Figure 1: Thermo camera image of a volunteer experiment showing the typical edge effect. 2 Theoretical calculation Human skin at the preferred locations for application of a neutral electrode (e.g. thigh, upper arm, buttock) consists of several layers with various electrical conductivities. From the only rarely available information about electrical properties of skin in the literature [2, 3] the thigh-model is composed of the various skin layers, the muscle and the bone. Neutral electrode Hypodermis Epidermis Corium Muscle tissue Bone ( no conductivity ) Center line Figure 2: Skin layers of a thigh used in model calculations and as basis for the resistor network.

Modelling in Medicine and Biology VI 573 In detail the model contains the epidermis (0,1 mm thickness, 2000 Ohm cm specific conductivity), corium (1,5 mm, 290 Ohm cm), hypodermis with fat (15 mm, 1600 Ohm cm), muscle (65 mm, 200 Ohm cm) and bone (no conductivity) as shown in Fig. 2. The neutral electrode for the model is a standard adult type with approximately 130cm² active area (80 x 170 mm). This volume conductor causes a current concentration around the edges of the neutral electrode ( edge effect ) and therefor an excessive heating at the highest current densities. The electronic simulation of the skin must therefor reproduce the current flow inside the skin and muscle tissue to generate the same energy distribution (and heating effects) as in the patient s skin. 3 Electronic realization The device is realized as a stack of pcb-boards with a gold plated surface for the attachment of the neutral electrode under test. This surface is divided into 1 cm² sized squares, each of them connected to a network of resistors at the rear side. This network corresponds to the specific impedance in horizontal and vertical direction of the respective skin layers for a prism with 1 cm² cross section each. Fig. 3 gives an impression of this network. Ge Neutral electrode line 1 OP-site near edge line 2 line 3 Figure 3: Principle of impedance network for skin simulation One of the network prisms as symbolized in Fig. 3 is shown in more details in Fig. 4. A group of 6 resistors each represent one skin layer. In a next development step this impedance network is simplified and optimized to correspond with the current distribution found in model calculations. The values of the impedances are dimensioned to simulate the worst case of a thermal sensitive volunteer (AAMI).

574 Modelling in Medicine and Biology VI 1 cm² of the Electrode Rh Rv Rh Epidermis Rv = 10 Ω Rh = 100 kω Corium Rv = 22 Ω Rh = 1000 Ω Hypodermis Rv = 1200 Ω Rh = 500 Ω Muscle tissue Rv = 300 Ω Rh = 16 Ω Figure 4: Three dimensional R-network for representation of the electrical features of the human skin. For each square centimeter of resistor network a transistor as temperature sensor is in thermal contact to measure the local temperature. The temperature dependent base-emitter voltage is scanned by a computer controlled electronic. By comparing the temperature before and after the application of the standard load according to AAMI HF-18 (700 ma during 60 s for adult sized neutral electrodes) the relevant temperature increase is calculated as the difference of the local temperature values. Contact area divided into 1 cm² sections 1 cm² Neutral electrode under test 1 temperature sensor for each cm² Electronic circuit representing 1 cm² of skin Figure 5: Measuring table and its components.

Modelling in Medicine and Biology VI 575 The final device swarotest consists of the main unit including the frequency generator, amplifier, control logic and the serial interface for the connection to the PC and the measuring table to hold the neutral electrode under test. The measuring table has a gold plated surface with a dimension of 12 x 22 cm, divided into electrically separated areas of 1 cm² each to be connected to the electronic network described above. Figure 6: The device swarotest. The control software is self explanatory and starts with a selection of the measuring parameters to adopt the temperature measurement to different skin properties and electrode sizes (e.g. adult electrodes need 700 ma for test, infant 500 ma). Figure 7: Starting screen with parameter selection and temperature control.

576 Modelling in Medicine and Biology VI The green field indicates the temperature increase / decrease of the measuring area, thus indicating whether after a previous measurement the surface temperature has already stabilized (thermal equilibrium) and the next measurement may be started. This uniform green field indicates no temperature change, the next measurement can start. Figure 8: Starting screen indicating a cooling in progress. Fig. 8 shows the starting screen while cooling (blue colors) and partly warming (yellow and red colors) is in progress. A measurement under this conditions would lead to false results. The measurements itself runs fully automatically and displays the result on the PC screen. After start of measurement the current trough the neutral electrode is kept constant by a closed loop control for 60 s. After the heating period the temperatures in the measuring transistors are scanned and the temperature difference to the cold measurement is calculated. A typical result is shown in fig 9. Figure 9: Result of a temperature measurement.

Modelling in Medicine and Biology VI 577 Test measurements with several types of neutral electrodes under various test conditions showed a close correlation with the thermo camera images measured in volunteer experiments. The test parameters for the result displayed in fig. 9 were similar to those found in the volunteer test in fig 1. The coincidence of the temperature profile proves that the swarotest device can replace volunteer experiments. For a more detailed view a relief representation can be selected and rotated to give an impressive view of the temperature increase. 4 Results Figure 10. According to the requirements of the AAMI HF18 standard a device replacing volunteer experiments must prove to yield the same results as the volunteer experiments for comparable conditions. Therefor we have performed more than 30 volunteer experiments and compared them with the results of our swarotest device. 5 Conclusions This new device swarotest is an electronic replacement for thermal tests of neutral electrodes under AAMI HF 18 conditions. The electronic skin simulates the various skin layers by electronic circuits in a way to yield the same current distribution and the same heating effect as found in volunteers. The results are reproducible and by far less laborious compared with volunteer experiments The device swarotest can be used for quality test in a production process and for evaluation of new designs of neutral electrodes and replace volunteer experiments. This yields reproducable results at low cost within a short time

578 Modelling in Medicine and Biology VI References [1] American National Standard Institute ANSI/AAMI HF18-93, Association for the Advancement of Medical Instrumentation, Electrosurgical Devices, Arlington, USA, 1993 [2] Gabriel S., Lau R.W., Gabriel C., The dielectric properties of biological tissue: II Measurements in the frequency range 10 Hz to 20 GHz, Phy. Med. Biol. 41, 2251-2293, 1996 [3] Edrich J., Cookson C. C., Electrosurgical dispersive electrodes heat cutaneous and subcutaneous skin layers, Medical Instrumentation Vol 21, p 81-86, 1987 [4] Nessler N., Die Neutralelektrode bei der Elektrochirurgie, ein Risiko für den Patienten?, Österreichische Krankenhauszeitung ÖKZ, 12/95, p 29-34, 1995 [5] Nessler N., Current density distribution in Human skin under the Grounding electrode of Electrosurgery, BEMS 17th Annual Meeting, Boston, MA., 1995 [6] Nessler N., Huter H., Wang L., Sicherheitstester für HF-Chirurgie- Neutralelektroden, Biomedizinische Technik Vol 38, p 5-9, 1993 [7] Nessler N, Reischer W., The neutral electrode in electrosurgery, a risk for the patient?, MEDICON 2001, Pula [8] Nessler N, Reischer W., Salchner M. Electronic skin test device for electrosurgical neutral electrodes, 12 th IMEKO TC4 International Symposium, Zagreb 2002