PHOENIX CONTACT - 04/2016. Features

Similar documents
ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:

Non-Contact Safety Systems CMS

TF 202 / TF 202-Ex. Field mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

ISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

POINTS OF CAUTION BEFORE USE...

Digital Current Transducer HO-SW series I P N = A. Ref: HO 100-SW; HO 150-SW; HO 200-SW; HO 250-SW

S95.3U01 / S95.3U11. Head mounted temperature transmitters, programmable, Pt 100 (RTD), thermocouples, electrical isolation

Thermal-Magnetic Circuit Breaker 2210-T2...

Ref: HLSR 16-PW; HLSR 32-PW; HLSR 40-PW-000; HLSR 50-PW-000,

BEFORE USE... POINTS OF CAUTION COMPONENT IDENTIFICATION INSTRUCTION MANUAL MODEL R7K4DH-1-DAC32D R7K4DH-1-DAC32D

Installation guide 862 MIT / MIR

T20WN. Data Sheet. Torque transducers. Special features. Installation example with bellows couplings. B en

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Pressure transmitters for industrial applications MBS 32 and MBS 33

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-T...

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.

The Ordering Code for various standard model Recorders with an AC supply and without any additional options are as follows:

Operating Instructions for Digital Manometer. Model: MAN-SD

RoHS. Versatile. X g. X 2 e

SINEAX VK 636 Programmable Temperature Transmitter with PROFIBUS-PA protocol

TF 212 / TF 212-Ex. Field mounted temperature transmitters, PROFIBUS PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels 10/11-8.

SCTP20 Programmable 2-Wire Temperature Transmitter, Head Mount

S95.3U02 / S95.3U12. Head mounted temperature transmitters, HART programmable, Pt 100 (RTD), thermocouples, electrical isolation

Drive electronics pq12

5SJ4...-.HG Circuit Breakers to IEC and UL 489

Operating instructions Pressure sensor PN / / 2007

Overload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011

HYGRASGARD KFF KFTF HYGRASGARD AFF AFTF HYGRASGARD AFF - LC AFTF - LC

ED 701 General Industry Pressure Transmitter

Safety Precautions WARNING If critical situations that could lead to user s death or serious injury is assumed by mishandling of the product.

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

MODEL: R7K4FML3. Remote I/O R7K4F Series. POWER INPUT DC power R: 24 V DC (Operational voltage range: ±10 %; ripple 10 %p-p max.)

Multi-function, economical instrument with 4 functions in the same casing. Accessibility and safety: large-dimension terminals Insulated circuits

E8EB-N0C2B E8EB-N0B2B

AIR CONDITIONER (SPLIT TYPE) SERVICE MANUAL

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

PTF30 Series. Features. Ordering information. G 6 N N F8 (0 to 5 kgf/cm 2 ) PTF30

User Manual VX4750 Function Generator Module

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH1BVW S/08

BMXART0814 analog input module M340-8 inputs - temperature

Type Function Output config. Auxiliary Case Page

Linear measuring technology

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27

TH 202 / TH 202-Ex. Field mounted temperature transmitter, HART programmable, Pt 100 (RTD), thermocouples, electrical isolation. ABB Instrumentation

To order, specify : Types Protection functions Current surge Asymmetry and loss of phase. Operating principle

Varius SUMMARY OF MODELS OF HRC FUSE-LINKS

Page 1 of 16 Issue No. 0 of IECEx TUN X

DS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

LED light engine / OLED LED compact. Uengine DLE G2 integrated ADV

3B SCIENTIFIC PHYSICS

PHASED OUT. LED light engine / OLED LED compact. Umodule SLE G4 15mm 2000lm 8x0 H ADV D50

PHASED OUT. LED light engine / OLED LED compact. Umodule SLE G4 15mm 2000lm 9x0 H EXC D50

SINEAX VK 626 Programmable Temperature Transmitter for RTD and TC inputs, with HART protocol

5-V Low Drop Fixed Voltage Regulator TLE

D5.2 Type. Draw wire mechanics with incremental encoder. Measuring length max. 2 m. Compact and simple. Order code draw wire encoder

Online data sheet WL280-S230 W280 COMPACT PHOTOELECTRIC SENSORS

Lamp and Control Panel (Lamp Panel)

ABB i-bus KNX Analogue Input AE/A 2.1

DC/DC regulator Input V Output up to 16 A

SC125MS. Data Sheet and Instruction Manual. ! Warning! Salem Controls Inc. Stepper Motor Driver. Last Updated 12/14/2004

Welcome. Functionality and application of RTD Temperature Probes and Thermocouples. Dipl.-Ing. Manfred Schleicher

BETA Protecting Miniature Circuit Breakers

Proximity Sensor Ideal for High Temperatures and Cleaning Processes. Applicable to 120 C

Thermal-Magnetic Circuit Breaker 2210-S2..

5SP and 5SY Supplementary Protection UL 1077

Low Drop Voltage Regulator TLE 4295

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

5-V Low Drop Fixed Voltage Regulator TLE 4275

Thermal-Magnetic Circuit Breaker 2210-S2..

Universal limit switches

Field mounted Temperature Transmitter TF212/TF212-Ex

Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level

Z7A. Load cells. Special features. Data sheet. Wiring code

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HC6H 400-S/SP1

LED light engine / OLED LED compact. Module DLE G4 ADV Modules DLE

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

LED light engines LED compact. Module SLE G7 ADV Modules SLE ADVANCED

Low Drop Voltage Regulator TLE 4296

Thermal-Magnetic Circuit Breaker 2210-S2..

FL ballasts Electronic fixed output. PC TC PRO sr 1/2x11 42 W PC PRO compact

Field IT 50T Series Transmitters

Meteorological Station P03/3-RS485-WAGO

TeSys circuit-breakers

LEDlight 20 W Universal dimmable series

PHASED OUT. LED light engine / OLED LED compact. Umodule SLE G4 FOOD EXC

Low Drop Voltage Regulator TLE

THM80X Series Feature Application. Temperature & Humidity / Flow Measuring Specialist

Time - timing relays 1 Industrial relays, solid state output, width 22.5 mm

BASE. Rotary limit switch. OptiOnS. FEAtuRES. CERtiFiCAtiOnS

U LED modules, converters and systems GENERAL ILLUMINATION. Umodule SPOT P330-3 EM umodule SPOT PHASED OUT NTC NTC LED + LED + LED EM LED EM

XD1-L Cable Differential Protection Relay

3.3V Power Supply Isolated Current Sensor with Common Mode Field Rejection

U LED modules, converters and systems GENERAL ILLUMINATION. Umodule SPOT P320-3 umodule SPOT PHASED OUT 46,5 39,5 35,5 NTC NTC LED + LED 8,5 4,5 8,5

Film Capacitors. EMI suppression capacitors. Date: June 2018

Thermal-Magnetic Circuit Breaker 2210-S2...

Thermal-Magnetic Circuit Breaker 2210-S2...

Transcription:

Signal conditioner Data sheet 100238_de_06 1 Description PHOENIX CONTACT - 04/2016 Features The MCR-C-UI-UI(-450)-DCI(-NC) 3-way isolation amplifier is used to electrically isolate and convert analog signals. The device provides electrical isolation of analog standard signals. The module input and output are supplied via integrated DC/DC converters, which are electrically isolated from the mains (3-way isolation). The required auxiliary voltage is indicated via a green power LED. This clearly indicates whether or not auxiliary voltage is available. The MCR module ensures the safe decoupling of a sensor circuit from the evaluation circuit and also prevents the negative effects of several sensor circuits connected with one another. 3-way isolation enables the universal use of modules both locally and close to the control system for signal conversion and electrical isolation, as well as on the transmission path for jumpering high load resistors. Signals are converted by an inductive transmission method. In addition, a filter connected downstream of the transmitter reduces possible interference. Configurable 3-way signal conditioners Input and output signal range can be configured via DIP switches ZERO/SPAN adjustment using potentiometers Can be supplied configured or unconfigured WARNING: Correct usage in potentially explosive areas The module is a category 3 item of electrical equipment. Follow the instructions provided here during installation and observe the safety instructions. Make sure you always use the latest documentation. It can be downloaded from the product at phoenixcontact.net/products. This data sheet is valid for all products listed on the following page:

2 Ordering data Description Type Order No. Pcs./Pkt. Signal conditioner, Pluggable screw connection, with a limit frequency (3 db) 30 Hz, Order configuration Signal conditioner, Pluggable screw connection, with limit frequency (3 db) 450 Hz, without GL and UL approval, Order configuration Signal conditioner, Pluggable screw connection, with a limit frequency (3 db) 30 Hz, Standard configuration 2810913 1 MCR-C-UI-UI-450-DCI 2810887 1 -NC 2810939 1 3 Order key (standard configuration entered as an example) Order No. Input Output Factory Calibration Certificate 2810913 / IN03 / OUT03 / NONE 2810913 = IN01 = 0... 20 ma IN18 = -1... +1 V IN28 = 0... 500 mv OUT01 = 0... 20 ma NONE = Without factory IN02 = 4... 20 ma IN19 = -2... +2 V IN29 = 0... 1 V OUT02 = 4... 20 ma calibration certificate IN03 = 0... 10 V IN20 = -2.5... +2.5 V IN30 = 0... 2 V OUT03 0... 10 V 2810887 = IN05 = 0... 5 V IN21 = -5... +5 V IN31 = 0... 2.5 V OUT05 = 0... 5 V MCR-C-UI-UI-450-DCI IN06 = 1... 5 V IN22 = -10... +10 V IN32 = 0... 20 V OUT06 = 1... 5 V YES = With factory calibration certifi- IN13 = -60... +60 mv IN23 = -20... +20 V IN33 = -5... +5 ma OUT13 = -5... +5 V IN14 = -100... +100 mv IN24 = 0... 60 mv IN34 = -10... +10 ma OUT14 = -10... +10 V cate (a fee is IN15 = -200... +200 mv IN25 = 0... 100 mv IN35 = -20... +20 ma OUT15 = 0... 5 ma charged) IN16 = -300... +300 mv IN26 = 0... 200 mv IN36 = 0... 5 ma OUT16 = 0... 10 ma IN17 = -500... +500 mv IN27 = 0... 300 mv IN37 = 0... 10 ma YESPLUS = Factory calibration certificate with 5 measuring points (a fee is charged) Combination Table for Input and Output Signals Voltage Output Current Output Input 0... 10 V ±10 V 0... 5 V ±5 V 1... 5 V 0... 5 ma 0... 10 ma0... 20 ma4... 20 ma 0... 60 mv x x x x x x x x x 0... 100 mv x x x x x x x x x 0... 200 mv x x x x x x x x x 0... 300 mv x x x x x x x x x 0... 500 mv x x x x x x x x x 0... 1 V x x x x x x x x x 0... 2 V x x x x x x x x x 0... 2.5 V x x x x x x x x x 0... 5 V x x x x x x x x x 0... 10 V x x x x x x x x x 0... 20 V x x x x x x x x x ±60 mv x x x x x x ±100 mv x x x x x x ±200 mv x x x x x x ±300 mv x x x x x x ±500 mv x x x x x x ±1 V x x x x x x ±2 V x x x x x x ±2.5 V x x x x x x ±5 V x x x x x x ±10 V x x x x x x ±20 V x x x x x x 0... 5 ma x x x x x x x x x 0... 10 ma x x x x x x x x x 0... 20 ma x x x x x x x x x ±5 ma x x x x x x ±10 ma x x x x x x ±20 ma x x x x x x 1... 5 V x x x x x x x x 4... 20 ma x x x x x x x x 100238_de_06 PHOENIX CONTACT 2

4 Technical data Signal input Configurable/programmable MCR-C-UI-UI-450-DCI Configurable/programmable -NC Voltage input signal Max. voltage input signal Max. current input signal Input resistance of voltage input Input resistance current input Signal output Max. current output signal Voltage output signal Max. voltage output signal Configurable/programmable MCR-C-UI-UI-450-DCI Configurable/programmable -NC Load/output load voltage output Load/output load current output Supply Supply voltage range Max. current consumption Yes, preconfigured Yes, standard configuration IN 0... 10 V, OUT 0... 10 V 0 V... 10 V (please indicate if different setting when ordering) 30 V 50 ma 1 MΩ 50 Ω 30 ma 0 V... 10 V (please indicate if different setting when ordering) 15 V Yes, preconfigured Yes, unconfigured 10 kω 500 Ω 18 V DC... 30 V DC < 30 ma (without load) General data Limit frequency (3 db) -NC 30 Hz Limit frequency (3 db) 450 Hz MCR-C-UI-UI-450-DCI Measuring principle Signaltrennverstärker Maximum transmission error 0.1 % (of final value) Maximum temperature coefficient 0.0075 %/K Alignment zero ± 2 % Alignment span ± 2 % Step response (10-90%) 11 ms ( 30 Hz ) / 0.8 ms ( 450 Hz ) Mounting position any Degree of protection IP20 Dimensions W/H/D 17.5 mm / 99 mm / 114.5 mm Type of housing Polyamide PA non-reinforced green Connection data Conductor cross section, solid Conductor cross section, flexible Stripping length 0.2 mm²... 2.5 mm² 0.2 mm²... 2.5 mm² 8 mm 100238_de_06 PHOENIX CONTACT 3

Safe isolation Test voltage input/output Test voltage power supply/signal 1.5 kv (50 Hz, 1 min.) 1 kv (50 Hz, 1 min.) Ambient conditions Ambient temperature (operation) -20 C... 65 C Conformance / approvals Conformance UL, USA / Canada CE-compliant UL 508 Recognized Class I, Div. 2, Groups A, B, C, D Class I, Zone 2, Group IIC Conformance with EMC Directive 2004/108/EC (valid until 19.04.2016) / 2014/30/EU (valid from 20.04.2016) Noise immunity according to EN 61000-6-2 Noise emission according to EN 61000-6-4 5 Block diagram IN OUT IN U/I 1 2 3 U, U 7 8 9 OUT I OUT U GND 2 10 11 12 +24V DC 100238_de_06 PHOENIX CONTACT 4

6 Safety notes WARNING: Correct usage in potentially explosive areas The module is a category 3 item of electrical equipment. Follow the instructions provided here during installation. Install the module in housing with IP54 protection according to EN 60529. The specified limits for mechanical strain or thermal loads for the module must not be exceeded. Only modules suitable for operation in zone 2 potentially explosive areas may be connected. Repairs must not be carried out by the user. In potentially explosive areas, snap the module onto the DIN rail and connect the cables only when the power is disconnected. CAUTION: Installation, operation, and maintenance may only be carried out by qualified electricians. When installing and operating the device, the applicable safety directives (including national directives), accident prevention regulations, as well as general technical regulations, must be observed. CAUTION: Electrostatic discharge The module contains components that can be damaged or destroyed by electrostatic discharge. When handling the module, observe the necessary safety precautions against electrostatic discharge (ESD) according to EN 61340-5-1 and IEC 61340-5-1. 100238_de_06 PHOENIX CONTACT 5

7 Structure 5 4 U/I GND1 GND1 IN 3 SPAN ZERO OUT +24V GND3 GND3 I U GND2 2 1 DIP switches S1 and S2 are located inside the housing. 1 Supply voltage 2 Output: Standard signals 3 "ZERO" and "SPAN" potentiometers 4 "" LED 5 Input: Standard signals 6 Universal snap-on foot for EN DIN rails 1 2 3 MCR -C-UI/UI -DCI Art.-Nr.: 28 10 91 3 2 1 IN U/I OUT I OUT U GND 2 12 9 +24VDC 10 11 7 8 APPROBATIONEN / 6 8 Power supply Power Supply via the Connection Terminal Blocks The current measuring transducer is connected to the power supply at the "+24VDC" and "GND" connection terminal blocks (see block diagram). 100238_de_06 PHOENIX CONTACT 6

9 Installation A B B 2 WARNING: In potentially explosive areas, snap the module onto the DIN rail and connect the cables only when the power is disconnected. The assignment of the connection terminal blocks is shown in the block diagram. The module can be snapped onto all 35 mm DIN rails according to EN 60715. Assembly Position the module with the DIN rail guide on the upper edge of the DIN rail, and snap it in with a downward motion. Removing B 1 Pull the snap lever open with the aid of a screwdriver and slide the module out at the lower edge of the DIN rail. Screw Connection B SPAN ZERO OUT +24V GND3 GND3 I U GND2 Insert the wires in the corresponding connection terminal block. Use a screwdriver to tighten the screw in the opening above the connection terminal block. IN U/I GND1 GND1 1 2 3 A MCR -C-UI/UI -DCI Art.-Nr.: 28 10 91 3 2 1 IN U/I OUT I OUT U GND 2 12 9 +24VDC 10 11 7 8 APPROBATIONEN / 100238_de_06 PHOENIX CONTACT 7

10 Configuration CAUTION: Electrostatic discharge The module contains components that can be damaged or destroyed by electrostatic discharge. When handling the module, observe the necessary safety precautions against electrostatic discharge (ESD) according to EN 61340-5-1 and IEC 61340-5-1. HYBRID TV1 DIP 1 PHOENIX CONTACT DIP 2 If the modules are not configured (all DIP switches set to pos. 0), the module does not have a defined function until the DIP switches have been set. DIP switches S1 and S2 specify the combination of input and output standard signal ranges (see configuration table). Standard Configuration "NC" versions (...-NC) have the following standard configuration: 0... 10 V input 0... 10 V output (All DIP switches are set to the "OFF" position) Opening the Module Using a screwdriver, release the locked upper housing part on both sides. The upper housing part and the electronics can now be pulled out approximately 3 cm. 11 Adjustment The "ZERO" potentiometer is used to adjust the zero point of the module and the "SPAN" potentiometer is used to adjust the final value. Both potentiometers are located on the top of the module. NOTE: Module can become damaged Before commencing the adjustment process, observe the warm-up phase of two minutes. 100238_de_06 PHOENIX CONTACT 8

12 DIP switches X = ON Input 0... 5 V Output 0... 10 V Output ±5 V Output ±10 V Output DIP 1 DIP 2 DIP 2 DIP 2 DIP 2 Input 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 910 1 2 3 4 5 6 7 8 910 1 2 3 4 5 6 7 8 910 1 2 3 4 5 6 7 8 910 0... 60 mv X X X X X X X X X X X X X X X X X X X X 0... 100 mv X X X X X X X X X X X X X X X X X X 0... 200 mv X X X X X X X X X X X X X X X X X X 0... 300 mv X X X X X X X X X X X X X X X X X X X 0... 500 mv X X X X X X X X X X X X X X X X X X 0... 1 V X X X X X X X X X X X X X X X X X X 0... 2 V X X X X X X X X X X X X X X X X X X 0... 2.5 V X X X X X X X X X X X X X X X X X 0... 5 V X X X X X X X X X X X X X X X X X 0... 10 V X X X X X X X X X X X X X X X X X 0... 20 V X X X X X X X X X X X X X X X X X ±60 mv X X X X X X X X X X X X X X X X ±100 mv X X X X X X X X X X X X X X ±200 mv X X X X X X X X X X X X X X ±300 mv X X X X X X X X X X X X X X X ±500 mv X X X X X X X X X X X X X X ±1 V X X X X X X X X X X X X X X ±2 V X X X X X X X X X X X X X X ±2.5 V X X X X X X X X X X X X X ±5 V X X X X X X X X X X X X X ±10 V X X X X X X X X X X X X X ±20 V X X X X X X X X X X X X X 0... 5 ma X X X X X X X X X X X X X X X X X X X X X 0... 10 ma X X X X X X X X X X X X X X X X X X X 0... 20 ma X X X X X X X X X X X X X X X X X X X ±5 ma X X X X X X X X X X X X X X X X X ±10 ma X X X X X X X X X X X X X X X ±20 ma X X X X X X X X X X X X X X X 1... 5 V X X X X X X X X X X X 4... 20 ma X X X X X X X X X X X X X X = ON 1... 5 V Output 0... 5 ma Output 0... 10 ma Output 0... 20 ma Output 4... 20 ma Output DIP 2 DIP 2 DIP 2 DIP 2 DIP 2 Input 1 2 3 4 5 6 7 8 910 1 2 3 4 5 6 7 8 910 1 2 3 4 5 6 7 8 910 1 2 3 4 5 6 7 8 910 1 2 3 4 5 6 7 8 910 0... 60 mv X X X X X X X X X X X X X 0... 100 mv X X X X X X X X X X X X X 0... 200 mv X X X X X X X X X X X X X 0... 300 mv X X X X X X X X X X X X X 0... 500 mv X X X X X X X X X X X X X 0... 1 V X X X X X X X X X X X X X 0... 2 V X X X X X X X X X X X X X 0... 2.5 V X X X X X X X X X X X X X 0... 5 V X X X X X X X X X X X X X 0... 10 V X X X X X X X X X X X X X 0... 20 V X X X X X X X X X X X X X ±60 mv X X X X X X X ±100 mv X X X X X X X ±200 mv X X X X X X X ±300 mv X X X X X X X ±500 mv X X X X X X X ±1 V X X X X X X X ±2 V X X X X X X X ±2.5 V X X X X X X X ±5 V X X X X X X X ±10 V X X X X X X X ±20 V X X X X X X X 0... 5 ma X X X X X X X X X X X X X 0... 10 ma X X X X X X X X X X X X X 0... 20 ma X X X X X X X X X X X X X ±5 ma X X X X X X X ±10 ma X X X X X X X ±20 ma X X X X X X X 1... 5 V X X X X X X X X 4... 20 ma X X X X X X X X ±5 V Output ±10 V Output 1... 5 V Output 0... 20 ma Output 4... 20 ma Output Constant 10 V 20 V 4 V 18 ma 16 ma Output final value 5V 10V 5V 20mA 20mA Adjustment tolerance ±0.5 mv ±0.5 mv ±1 mv ±1 μa ±1 μa 100238_de_06 PHOENIX CONTACT 9

13 Specifying the Input Signal Range via DIP Switch 1 Select one of the possible signal ranges using the appropriate configuration of DIP switch 1 according to the table. Exception: Bipolar input signals are not permitted for the 4... 20 ma and 1... 5 V output signal ranges. 14 Specifying the Output Signal Range via DIP Switch 2 Output With Simple Adjustment (0... 5 V/0...10 V) Set the output range via DIP switch 2. Please note the selected input range. Specify the initial and final value of the input signal using a calibration device. Adjust the output value with a digital multimeter. Adjustment after specifying the initial and final value for the 0... 5 V output: Set 0 V ±0.5 mv at the "ZERO" potentiometer and 5 V ±0.5 mv at the "SPAN" potentiometer. Adjustment after specifying the initial and final value for the 0... 10 V output: Set 0 V ±0.5 mv at the "ZERO" potentiometer and 10 V ±0.5 mv at the "SPAN" potentiometer. Output With Adjustment Point Calculation (±5 V/±10 V/1... 5 V/0... 5 ma/0... 10 ma/0... 20 ma/4... 20 ma) Set the output range via DIP switch 2. Please note the selected input range. Specify the initial and final value of the input signal using a calibration device. Record the output value measured with a digital multimeter. For adjustment with the calibration device, specify the final value of the input signal range as follows: "SPAN" potentiometer: Full-scale adjustment point A ± adjustment tolerance "ZERO" potentiometer: Output final value ± adjustment tolerance Calculation of full-scale adjustment point A: A = Measured value 2 x Constant/Measured value 2 - Measured value 1 ±5 V, ±10 V, 1... 5 V, 4... 20 ma output signal ranges: If the initial value is specified at the input, measured value 1 is output at the output. If the final value is specified at the input, measured value 2 is output at the output. 0... 20 ma output signal range: If the initial value +10% of the range is specified at the input, measured value 1 is output at the output. If the final value is specified at the input, measured value 2 is output at the output. For the values for the constant, output final value, and adjustment tolerance, please refer to the corresponding tables. 100238_de_06 PHOENIX CONTACT 10

15 Connection example Level sensor 24V 0...20mA 1 U/I OUT T 7 (+) 24V 10 2 3 SPAN ZERO U GND 2 8 9 11 12 24V Mains voltage 0...10V Control unit 100238_de_06 PHOENIX CONTACT GmbH & Co. KG 32823 Blomberg Germany 11 phoenixcontact.com