Flexible A-scan rate MHz OCT: Computational downscaling by coherent averaging

Similar documents
Let us consider a typical Michelson interferometer, where a broadband source is used for illumination (Fig. 1a).

Blood flow measurement and slow flow detection in retinal vessels with Joint Spectral and Time domain method in ultrahigh speed OCT

Analysis of the signal fall-off in spectral domain optical coherence tomography systems

Quantum Imaging Technologies: Quantum Laser Radar

Motion artifacts in optical coherence tomography with frequency-domain ranging

Ultrafast Wavelength Tuning and Scaling Properties of a Noncollinear Optical Parametric Oscillator (NOPO)

Spectrally controlled source for interferometric measurements of multiple surface cavities Jan Posthumus 1,2

ABSTRACT. Introduction

10. OPTICAL COHERENCE TOMOGRAPHY

Quantum Imaging Technologies: Quantum Laser Radar

Advanced Optical Coherence Tomography techniques: novel and fast imaging tools for non-destructive testing

Resolution improvement in optical coherence tomography with segmented spectrum management

BNG/ECE 487 FINAL (W16)

University of Lübeck, Medical Laser Center Lübeck GmbH Optical Coherence Tomography

Do we need quantum light to test quantum memory? M. Lobino, C. Kupchak, E. Figueroa, J. Appel, B. C. Sanders, Alex Lvovsky

Rydberg excited Calcium Ions for quantum interactions. Innsbruck Mainz Nottingham

On Signal to Noise Ratio Tradeoffs in fmri

REPORT DOCUMENTATION PAGE

LIGO s Thermal Noise Interferometer: Progress and Status

Differential Brillouin gain for improving the temperature accuracy and spatial resolution in a long-distance distributed fiber sensor

Degradation in the degree of polarization in human retinal nerve fiber layer

Graphene photodetectors with ultra-broadband and high responsivity at room temperature

Chapter 24 Photonics Question 1 Question 2 Question 3 Question 4 Question 5

CW-Lyman- Source for Laser Cooling of Antihydrogen in a Magnetic Trap

QuReP. Quantum Repeaters for Long Distance Fibre-Based Quantum Communication. Rob Thew. Coordinator: Nicolas Gisin

Lecture 11: Doppler wind lidar

Development of a Free Space, LED Illuminated Spectral-domain Optical Coherence Tomography Setup

System optimization of a long-range Brillouin-loss-based distributed fiber sensor

Two-electron systems

PART 2 : BALANCED HOMODYNE DETECTION

Renewal of the gage-block interferometer at INRIM

OPTI510R: Photonics. Khanh Kieu College of Optical Sciences, University of Arizona Meinel building R.626

Flow measurement without phase information in optical coherence tomography images

Phase-sensitive swept-source interferometry for absolute ranging with application to measurements of group refractive index and thickness

Squeezing manipulation with atoms

Optimisation using measured Green s function for improving spatial coherence in acoustic measurements

MEASUREMENT of gain from amplified spontaneous

Ultrafast Laser Physics!

Supplementary Figures

Chapter 2. Optical FMCW Reflectometry. 2.1 Introduction

Quantitative retinal blood flow measurement with. three-dimensional vessel geometry determination. using ultrahigh-resolution Doppler optical

Optoelectronic Applications. Injection Locked Oscillators. Injection Locked Oscillators. Q 2, ω 2. Q 1, ω 1

Low-coherence heterodyne photon correlation spectroscopy

Time-resolved ultrafast photocurrents and terahertz generation in freely suspended graphene

Elastic Constants and Microstructure of Amorphous SiO 2 Thin Films Studied by Brillouin Oscillations

Optical coherence tomography (OCT) is a ranging technique

Application of high-precision temperature-controlled FBG f ilter and light source self-calibration technique in the BOTDR sensor system

Quantum Dots for Advanced Research and Devices

A Multipass Optics for Quantum-Well-Pumped Semiconductor Disk Lasers

Contents Preface iii 1 Origins and Manifestations of Speckle 2 Random Phasor Sums 3 First-Order Statistical Properties

TDI Ranging for the GRACE-FO Laser Ranging Interferometer

Squeezed Light for Gravitational Wave Interferometers

Navigator Echoes. BioE 594 Advanced Topics in MRI Mauli. M. Modi. BioE /18/ What are Navigator Echoes?

Introduction to Fourier Transform Infrared Spectroscopy

Temperature Dependence of a Macrobending Edge Filter Based on a High-bend Loss Fiber

Modern optics Lasers

Galactic Structure Mapping through 21cm Hyperfine Transition Line

Lecture 20. Wind Lidar (2) Vector Wind Determination

Digital Trimulus Color Image Enhancing and Quantitative Information Measuring

The Cooper Union Department of Electrical Engineering ECE111 Signal Processing & Systems Analysis Final May 4, 2012

2. THE RATE EQUATION MODEL 2.1 Laser Rate Equations The laser rate equations can be stated as follows. [23] dn dt

Introduction to Medical Imaging. Medical Imaging

Vertically-Integrated Array-Type Miniature Interferometer as a Core Optical Component of a Coherence Tomography System for Tissue Inspection

Enhancing sensitivity of gravitational wave antennas, such as LIGO, via light-atom interaction

Control of the Laser Interferometer Space Antenna

IOMAC' May Guimarães - Portugal IMPACT-SYNCHRONOUS MODAL ANALYSIS (ISMA) AN ATTEMPT TO FIND AN ALTERNATIVE

Laser stabilization via saturated absorption spectroscopy of iodine for applications in laser cooling and Bose-Einstein condensate creation

Confocal Microscopy Imaging of Single Emitter Fluorescence and Hanbury Brown and Twiss Photon Antibunching Setup

Temporal analysis for implicit compensation of local variations of emission coefficient applied for laser induced crack checking

1. The range of frequencies that a measurement is sensitive to is called the frequency

Abstract Submitted for the DPP99 Meeting of The American Physical Society

Scattering properties of the retina and the choroids determined from OCT-A-scans

Guided Acoustic Wave Brillouin Scattering (GAWBS) in Photonic Crystal Fibers (PCFs)

UV-Vis optical fiber assisted spectroscopy in thin films and solutions

Squeezed Light and Quantum Imaging with Four-Wave Mixing in Hot Atoms

Realisation of Transparency below the One-Photon Absorption Level for a Coupling Laser Driving a Lambda System under EIT Conditions

Supplementary Information: Three-dimensional quantum photonic elements based on single nitrogen vacancy-centres in laser-written microstructures

Radio Interferometry and Aperture Synthesis

Introduction to Fourier Transform Infrared Spectroscopy

Ultrasound is a widely used, nonionizing, and costeffective

31545 Medical Imaging systems

Measuring Laser Diode Optical Power with an Integrating Sphere

Caution! Pay close attention to the special operation and safety instructions in the manual of the ultrasonic echoscope.

Dispersion encoded full range frequency domain optical coherence tomography

Effective testing for wafer reject minimization by terahertz analysis and sub-surface imaging

Fourier Transform Infrared Spectrometry

Physical Optics. Lecture 7: Coherence Herbert Gross.

Blood flow velocity quantification using splitspectrum amplitude-decorrelation angiography with optical coherence tomography

Fourier Transform Infrared. Spectrometry

Wavelet analysis identifies geology in seismic

SUPPLEMENTARY INFORMATION

Solvent-mediated aggregate formation of PNDIT2: Decreasing the available conformational subspace by introducing locally highly ordered domains

Chapter 2 Correlation Force Spectroscopy

Lab 3-4 : Confocal Microscope Imaging of Single-Emitter Fluorescence and Hanbury-Brown and Twiss Set Up, Photon Antibunching

PHYS 352. Shot Noise, 1/f Noise. current (which is rate of charge)

Sensing Rotation with Light: From Fiber Optic Gyroscope to Exceptional Points

CHIRP OPTICAL COHERENCE TOMOGRAPHY

Long Path Industrial OCT High-precision Measurement and Refractive Index Estimation

0.5 atoms improve the clock signal of 10,000 atoms

Observation of neutral hydrogen using FFT spectrometer Argos on a 5m telescope

Transcription:

Flexible A-scan rate MHz OCT: Computational downscaling by coherent averaging Tom Pfeiffer 1, Wolfgang Wieser 3, Thomas Klein 3, Markus Petermann 2,3, Jan-Phillip Kolb 1, Matthias Eibl 1 and Robert Huber 1,3 1 Institut für Biomedizinische Optik, Universität zu Lübeck, Peter-Monnik-Weg 4, 23562 Lubeck, Germany 2 Lehrstuhl für BioMolekulare Optik, Fakultät für Physik, Ludwig-Maximilians-Universität München, Oettingenstr. 67, 80538 Munich, Germany 3 Optores GmbH, Gollierstr. 70, 80339 Munich, Germany ABSTRACT In order to realize fast OCT-systems with adjustable line rate, we investigate averaging of image data from an FDML based MHz-OCT-system. The line rate can be reduced in software and traded in for increased system sensitivity and image quality. We compare coherent and incoherent averaging to effectively scale down the system speed of a 3.2 MHz FDML OCT system to around 100 khz in postprocessing. We demonstrate that coherent averaging is possible with MHz systems without special interferometer designs or digital phase stabilisation. We show OCT images of a human finger knuckle joint in vivo with very high quality and deep penetration. Keywords: Optical coherence tomography, OCT, tunable laser, Fourier domain mode locking, averaging, MHz OCT 1. INTRODUCTION Modern FDML lasers have paved the way to high fidelity swept source OCT systems with A-scan rates up to several MHz [1] and coherence lengths superior to usual spectrometer based systems [2, 3]. Today also other technologies can achieve MHz line rates [4-6]. While MHz-OCT enables many new applications such as wide field ophthalmic OCT [7-10], flicker free live 4D-OCT [11] and high resolution intravascular OCT without motion artifacts [12, 13], the short acquisition times always come at cost of system sensitivity. But there are clearly situations when image quality is more important than acquisition speed. Ideally the same OCT system could perform high speed imaging with reduced sensitivity and high sensitivity imaging at lower speed. Sadly the hardware of most high speed swept source OCT systems cannot run at arbitrary line rates, even though there are light sources with adjustable wavelength sweep repetition rate [14-17]. The reason is that the high performance optoelectronic periphery of modern OCT engines often needs to be specifically tailored to a certain line rate. In most real OCT systems analog electronic filters, the bandwidth of photo-receivers, the mechanical response of resonant galvanometer-scanners and much more has to be designed for a certain line rate to achieve shot noise limited sensitivity. An alternative approach to realize variable line rate OCT is to image fast and reduce the line rate afterwards in software by averaging, which also improves image quality. The ability of coherent averaging to reduce white Gaussian noise more effectively than incoherent averaging has already been demonstrated on OCT data [18, 19]. Only coherent averaging, which comprises averaging of fringes or the complex output of the FFT, can improve sensitivity in the same way as lower imaging speed does. Now on the one hand, coherent averaging should be highly compatible with FDML based MHz-OCT since FDML lasers exhibit very good phase stability and the high speed effectively suppresses negative effects by sample motion. On the other hand, the low transimpedance gain of MHz-OCT photodetectors increases the negative effect of non-gaussian correlated noises such as excess laser and ADC noise on the averaging result. These non-gaussian noise contributions are more resistant to complex averaging. Hence, white noises such as shot noise or Johnson noise are not necessarily the limiting factors for effective averaging in FDML based MHz OCT systems. So this paper investigates downscaling of A-scan rates in MHz-OCT by coherent averaging. 2. METHODS All data shown has been acquired using a home-built 3.2 MHz FDML laser and the stability of the interferometer was not optimized. The real system sensitivity was measured to be 106 db with an optical power of 40 mw on the sample. In one imaging experiment the sensitivity was artificially reduced to 70 db using an additional ND filter. In the

following we will denote the averaging of complex FFT outputs as coherent averaging and averaging of the absolute values of the FFT outputs as incoherent averaging. 3. RESULTS AND DISCUSSION To estimate an upper limit for the efficiency of coherent averaging we measured the decrease of the background noise over the number of a-scans averaged. Figure 1 illustrates the decrease of the background standard deviation due to coherent averaging. As can be read from the graph, coherent averaging efficiently reduces the background noise. Figure 1: Decrease of the background noise due to coherent averaging depending on the number of A-scans averaged. The data was acquired with blocked sample arm. Within one frame adjacent A-scans were averaged coherently and the background noise was measured within a depth area corresponding to the medium third of the averaged A-scan. The blue curve is the average of hundred curves acquired in this way while the gray curve indicates the theoretical limit for coherent averaging and the gray dashed line indicates the theoretical limit for incoherent averaging. However there is an deviation from the theoretical limit that increases with the number of A-scans averaged and is plotted in Figure 2. This averaging penalty is probably due to excess noise or ADC related noise becoming dominant. The spectral components of these noise sources do not have random phase distributions and are therefore more resistive to coherent averaging. As can be read from the graph, we should be able to downscale the a-scan rate of our system by a factor of 30 with a resulting sensitivity 1.25dB less than that of an comparable ideal 107 khz system. This of course is only true assuming that the signal isn t degraded due to A-scan to A-scan phase variations. Figure 2: The red line indicates the deviance of the measured decrease in background noise in Figure 1 to the theoretical limit for coherent averaging. To verify the benefit of coherent averaging we imaged a human finger knuckle joint covered with ultrasound gel pressed against a cover glass. Figure 3 gives a comparison of the effects of coherent and incoherent averaging, downscaling the system speed to an effective a-scan rate of 107 khz. To eliminate the speckle pattern 15 slightly displaced images were averaged incoherently. It should be noted that the cutlevels where set differently for the two resulting images. This is necessary for a fair comparison of the two averaging modalities because coherent averaging actually reduces the background instead of just better defining it as incoherent averaging does. We preferred this strategy to histogram equalization since the visual impression in the regions with signal is more comparable this way. Both averaging techniques vastly improve the image quality, though the difference between the two is not as dramatic

as may be expected. While we clearly see improved contrast due to the reduced uneven background in the case of coherent averaging, improved sensitivity, i.e. in this case seeing features which cannot be identified with the other technique, cannot be claimed. a) b) Figure 3: OCT images of human finger knuckle joint. The same dataset acquired with 3.2MHz OCT. The dataset consists of 15 frames with 60000 a-scans each. a) The a-scans were averaged incoherently in groups of 30 to form a single a-scan. All 15 frames were averaged incoherently. b) A-scans were coherently averaged to form a single a-scan in groups of 30. All 15 frames were then averaged incoherently. To examine the effect of coherent averaging on low sensitivity systems we reduced the system sensitivity to 70dB by attenuating the sample arm with an OD 1.8 neutral density filter and acquired images of a piece of orange as a stationary sample. Figure 4 compares the unaveraged result to a 30 times incoherently and a 30 times coherently averaged image. In this case the difference between the two averaging modalities is much more dramatic. While both techniques improve the image quality, the coherently averaged image reveals much more details and the uneven background that is most distinct in the middle third of the image is vastly reduced. Again, the cutlevels have been adjusted for the higher dynamic range in the coherently averaged case. The clearly visible advantages of coherent averaging indicate that it might be esapecially usefull to downscale the a-scan rate of sensitivity limited systems. The most obvious candidate might be retinal imaging systems, where the applicable sample arm power is limited.

a) b) c) Figure 4: Orange, imaged with -36dB attenuation. The dataset is one frame with 60000 a-scan. a) An image without any averaging was constructed stitching together every 30th a-scan to compase a frame b) The a-scans were averaged incoherently in groups of 30 to form a single A-scan. c) A-scans were coherently averaged to form a-single a-scan in groups of 30. 4. CONCLUSION AND OUTLOOK We have investigated the feasibility of coherent averaging of A-scans using a MHz FDML OCT system. We observe that coherent computational downscaling of a MHz OCT system is possible and useful up to a certain point. Especially low sensitivity OCT systems might significantly benefit from complex averaging, whereas systems already starting at ~106dB exhibit less improvement. It is therefore possible to demonstrate very high quality images acquired with a 3.2 MHz OCT. Our results indicate that the computational downscaling in software might especially be compatible with retinal MHz-OCT systems since they only have ~90dB system sensitivity. REFERENCES 1. Wieser, W., et al., Multi-Megahertz OCT: High quality 3D imaging at 20 million A-scans and 4.5 GVoxels per second. Optics Express, 2010. 18(14): p. 14685-14704. 2. Adler, D.C., et al., Extended coherence length Fourier domain mode locked lasers at 1310 nm. Optics Express, 2011. 19: p. 20930-20939. 3. Wieser, W., et al., Extended coherence length megahertz FDML and its application for anterior segment imaging. Biomedical Optics Express, 2012. 3(10): p. 2647-2657. 4. Fechtig, D.J., et al., Line-field parallel swept source MHz OCT for structural and functional retinal imaging. Biomedical Optics Express, 2015. 6(3): p. 716-735. 5. Choi, D.-h., et al., Spectral domain optical coherence tomography of multi-mhz A-scan rates at 1310 nm range and real-time 4D-display up to 41 volumes/second. Biomedical Optics Express, 2012. 3(12): p. 3067-3086. 6. Tsai, T.-H., et al., Ultrahigh speed endoscopic optical coherence tomography using micromotor imaging catheter and VCSEL technology. Biomedical Optics Express, 2013. 4(7): p. 1119-1132. 7. Kolb, J.P., et al., Ultra-widefield retinal MHz-OCT imaging with up to 100 degrees viewing angle. Biomedical Optics Express, 2015. 6(5): p. 1534-1552.

8. Klein, T., et al., Megahertz OCT for ultrawide-field retinal imaging with a 1050nm Fourier domain modelocked laser. Optics Express, 2011. 19(4): p. 3044-3062. 9. Blatter, C., et al., Ultrahigh-speed non-invasive widefield angiography. Journal of Biomedical Optics, 2012. 17(7): p. 0705051-0705053. 10. Klein, T., et al., Multi-MHz retinal OCT. Biomedical Optics Express, 2013. 4: p. 1890. 11. Wieser, W., et al., High definition live 3D-OCT in vivo: design and evaluation of a 4D OCT engine with 1 GVoxel/s. Biomedical Optics Express, 2014. 5(9): p. 2963-2977. 12. Wang, T., et al., Heartbeat OCT: in vivo intravascular megahertz-optical coherence tomography. Biomedical Optics Express, 2015. 6(12): p. 5021-5032. 13. Wang, T., et al., Intravascular optical coherence tomography imaging at 3200 frames per second. Optics Letters, 2013. 38: p. 1715-1717. 14. Yun, S.H., et al., High-speed wavelength-swept semiconductor laser with a polygon-scanner-based wavelength filter. Optics Letters, 2003. 28(20): p. 1981-1983. 15. Huber, R., et al., Amplified, frequency swept lasers for frequency domain reflectometry and OCT imaging: design and scaling principles. Optics Express, 2005. 13(9): p. 3513-3528. 16. Potsaid, B., et al. MEMS tunable VCSEL light source for ultrahigh speed 60kHz - 1MHz axial scan rate and long range centimeter class OCT imaging. 2012. 17. Bonesi, M., et al., Akinetic all-semiconductor programmable swept-source at 1550 nm and 1310 nm with centimeters coherence length. Optics Express, 2014. 22(3): p. 2632-2655. 18. Tomlins, P.H. and R.K. Wang, Digital phase stabilization to improve detection sensitivity for optical coherence tomography. Measurement Science and Technology, 2007. 18: p. 3365. 19. Szkulmowski, M. and M. Wojtkowski, Averaging techniques for OCT imaging. Optics Express, 2013. 21: p. 9757-9773.