Digital 3 1/2 digits monitor Set button for switch output HI or LO (PG-200) (PG-208) Digital 3 1/2 digits Power switch LO setting VR for switch output LO HI setting VR for switch output HI SPAN adjustment VR Zero adjustment VR FEATURES Excellent stability A semiconductor chip is used as pressure a sensing element. State of the art circuit technology guarantees excellent temperature compensation. Low power consumption Approx. 9000 hours (one year) continuous operation by 3.6 V lithium battery is expected due to the adoption time sharing operation method. Easy reading with a large LD display With pressure switches function Two independent pressure setting points of HI and LO With analog output (0 ~ 1 V) Meets DIN sizes W H D 40 mm PG-200 is for non-corrosive. PG-208 is corrosion resistant due to the use of stainless steel diaphragm. MODEL NUMER DESIGNATION Series name PG-200, PG-208 Rated pressure range Please refer to the LIST OF MODEL NUMERS when placing orders. P G - 2 0 0-1 0 2 G P - 3 - P 101:0 ~ 9.81 {0 ~ 0.1 kgf/cm 2 } 0 ~ 10 (When displayed in the unit of Pa) 102:0 ~ 98.1 {0 ~ 1 kgf/cm 2 } 0 ~ 100 (When displayed in the unit of Pa) 103:0 ~ 981 {0 ~ 10 kgf/cm 2 } 0 ~ 1 MPa(When displayed in the unit of Pa) Pressure reference G:Gauge VH:Gauge (Vacuum) AH:Absolute GP:Gauge Pa unit display GMP:Gauge (103 type only) Pa unit display VP:Gauge (Vacuum) Pa unit display AP:Absolute Pa unit display Installation P: Except for PG-208 S: Power lank: 3: (Analog output is available)
LIST OF MODEL NUMERS Pa version Pressure reference Gauge Absolute Rated pressure range 0 ~ 10 0 ~ 100 0 ~ 1000 0 ~ 100 0 ~ 100 abs abs PG-200-101GP-P PG-200-102GP-P PG-200-103GP-P PG-200-102VP-P PG-200-102AP-P PG-200-101GP-3-P PG-200-102GP-3-P PG-200-103GP-3-P PG-200-102VP-3-P PG-200-102AP-3-P PG-200-101GP-S PG-200-102GP-S PG-200-103GP-S PG-200-102VP-S PG-200-102AP-S For corrosive or liquids PG-200-101GP-3-S PG-200-102GP-3-S PG-200-103GP-3-S PG-200-102VP-3-S PG-200-102AP-3-S PG-208-102GP-S PG-208-103GP-S PG-208-102VP-S PG-208-102GP-3-S PG-208-103GP-3-S PG-208-102VP-3-S MPa PG-200-103GMP-P PG-200-103GMP-3-P PG-200-103GMP-S For corrosive or liquids PG-200-103GMP-3-S PG-208-103GMP-S PG-208-103GMP-3-S Non SI unit version Pressure reference {kgf/cm 2 } Rated pressure range Gauge Absolute 0 ~ 9.81 0 ~ 98.1 0 ~ 981 0 ~ 98.1 0 ~ 98.1 abs {0 ~ 1000 mmh2o} {0 ~ 1} {0 ~ 10} {0 ~ - 735 mmhg} {0 ~ 735 mmhg abs} mmh2o kgf/cm 2 mmhg A PG-200-101G-P A PG-200-102G-P A PG-200-103G-P A PG-200-102VH-P A PG-200-102AH-P A PG-200-101G-3-P A PG-200-102G-3-P A PG-200-103G-3-P A PG-200-102VH-3-P A PG-200-102AH-3-P A PG-200-101G-S A PG-200-102G-S A PG-200-103G-S A PG-200-102VH-S A PG-200-102AH-S For corrosive or liquids A PG-200-101G-3-S A PG-200-102G-3-S A PG-200-103G-3-S A PG-200-102VH-3-S A PG-200-102AH-3-S A PG-208-102G-S A PG-208-103G-S A PG-208-102VH-S A PG-208-102G-3-S A PG-208-103G-3-S A PG-208-102VH-3-S : Not available Verify the above model numbers when placing orders. The products marked A are manufactured upon receipt of order basis. <Option> D3.6 V lithium battery Order item: Lithium battery The battery is an expendable item. The first one is provided with the unit. ( )
STANDARD SPEIFIATIONS Pa version Unless otherwise specified, the specs are defined at an ambient temperature of 25 ± 5, excitation voltage of 12 V D and battery of 3.6 V D. Item PG-200 PG-208 Pressure reference Model number Rated pressure range Maximum pressure reak-dawn pressure 101GP 102GP Gauge Absolute Gauge 103GP 103GMP 102VP 102AP 102GP 103GP 103GMP 102VP 10 100 1000 100 100 abs 100 1000 100 20 200 1500 200 200 abs 200 2000 200 50 500 2000 500 500 abs 300 3000 300 Operating temp., range 0 ~ 50 General specifications ompensated temp. range Operating humidity Storage temp. Gravitational effect (From vertical position to horizontal position) %RH % F.S. Non-corrosive 0 ~ 50 35 ~ 85(No condensation) 20 ~ 70(Atmospheric pressure, humidity 65 %RH maximum) 1 orrosive /liquids compatible with SUS316 and SUS316L Approx. 0.5 Approx. 0.05 Approx. 0.5 Pressure port M 5 R 1/4(PT 1/4) G 3/8(PF 3/8) Net weight g Approx. 130 Approx. 330 Approx. 390 Power type Lithium battery D 3.6 V (ER6VM) life 9000 h minimum (Selectable by electrical terminals only in case of stand type) onsumption current : 20 ma maximum No. of digits 3 1/2 Display element LD Display Rated display range Display cycle Display accuracy maximum 0.00 ~ 10.00 100.0.000 ~ 1.000 (MPa) 100.0 100.0 Approx. 3 times/s ± 0.5 %F.S. ± 2 counts (at 25 ± 5 ) 100.0.000 ~ 1.000 (MPa) 100.0 Thermal error ZERO SPAN maximum ± 0.1 % F.S./ ± 2 counts ± 0.05 % F.S./ ± 2 counts ± 0.1 % F.S./ ± 2 counts ± 0.05 % Reading/ ± 2 counts Resolution 1 count 1 : will be limited to the ones compatible with Fluoro rubber when an O-ring supplied as an accessary is used and also compatible with the material of the joints.
STANDARD SPEIFIATIONS Pa version Unless otherwise specified, the specs are defined at an ambient temperature of 25 ± 5, excitation voltage of 12 V D and battery of 3.6 V D. Item PG-200 PG-208 Model number No. of setting points Switching capacity Residual voltage Output conditions 101GP 102GP 103GP 103GMP 102VP 102AP 102GP 103GP 103GMP 2 points of HI and LO (one point of HI only for the external power supply version) 30 V D 40 ma(npn open collector) 1.2 V D(When current inflow is 40 ma) 102VP Measured press LO set press. LO output ON, Measured press. HI set press. HI output ON. Switch Setting method When the SET button is pressed, HI set pressure is displayed for about 20 seconds first, then LO set pressure is displayed for about 20 seconds. Therefore, high and low pressure settings can be made by VR watching the display. Pressure setting range 0.00 ~ 10.00 100.0.000 ~ 1.000 (MPa) 100.0 100.0 100.0.000 ~ 1.000 (MPa) 100.0 Switch state indication Indicated by an LD display (HI or LO) when the switch output is ON. Response Approx. 100 ms Switching hysteresis 2 Analog voltage output Additional function 4 counts 以下 4 counts maximum Voltage output: 0 ~ 1 V, Accuracy: ± 1 %F.S. (at 25 ± 5 ), Load: 1 kω minimum Low battery indication (LO AT) Accessories (for panel type only) Attachements : Half union (for a tube of φ 6 0.D.), and arb fitting (for a tube of φ 4 I.D.), one piece each. ( only) 2 : Available only for external power type.
STANDARD SPEIFIATIONS Non SI unit version Unless otherwise specified, the specs are defined at an ambient temperature of 25 ± 5, excitation voltage of 12 V D and battery of 3.6 V D. Item PG-200 PG-208 Pressure reference Model number Rated pressure range {kgf/cm 2 } Maximum pressure {kgf/cm 2 } reak-dawn pressure {kgf/cm 2 } Operating temp., range Gauge Absolute Gauge 101G 102G 103G 102VH 102AH 102G 103G 102VH 9.81 98.1 981 98.1 98.1 abs 98.1 981 98.1 {1000 mmh2o} {1} {10} { 735 mmhg} {735 mmhg abs} {1} {10} { 735 mmhg} 19.6 196 1471 196 196 abs 196 1961 196 {2000 mmh2o} {2} {15} {1471 mmhg} {1471 mmhg abs} {2} {20} {1471 mmhg} 49.0 490 1961 490 490 abs 294 2941 294 {5000 mmh2o} {5} {20} {3678 mmhg} {3678 mmhg abs} {3} {30} {2206 mmhg} 0 ~ 50 General specifications ompensated temp. range Operating humidity Storage temp. Gravitational effect (From vertical position to horizontal position) %RH % F.S. Non-corrosive 0 ~ 50 35 ~ 85(No condensation) 20 ~ 70(Atmospheric pressure, humidity 65 %RH maximum) 1 orrosive /liquids compatible with SUS316 and SUS316L Approx. 0.5 Approx. 0.05 Approx. 0.5 Pressure port M 5 R 1/4(PT 1/4) G 3/8(PF 3/8) Net weight g Approx. 130 Approx. 330 Approx. 390 Power type Lithium battery D 3.6 V (ER6VM) life 9000 h minimum (Selectable by electrical treminals only in case of stand type) onsumption current : 20 ma maximum No. of digits 3 1/2 Display element LD Rated display range mmh2o.000 ~ 1.000 0.00 ~ 10.00 000 ~ 735 kgf/cm 2 kgf/cm 2 2 mmhg 000 ~ 735 2 mmhg.000 ~ 1.000 0.00 ~ 10.00 000 ~ 735 kgf/cm 2 kgf/cm 2 2 mmhg Display Display cycle Display accuracy maximum Approx. 3 times/s ± 0.5 %F.S. ± 2 counts (at 25 ± 5 ) Thermal error ZERO SPAN maximum ± 0.1 % F.S./ ± 2 counts ± 0.05 % F.S./ ± 2 counts ± 0.1 % F.S./ ± 2 counts ± 0.05 % Reading/ ± 2 counts Resolution 1 count 1 : will be limited to the ones compatible with Fluoro rubber when an O-ring supplied as an accessary is used and also compatible with the material of the joints. 2 : Measurement can be made up to - 760 mmhg for 102VH and up to 760 mmhg for 102AH (Accuracy not guaranteed beyond the rated pressure.).
STANDARD SPEIFIATIONS Non SI unit version Unless otherwise specified, the specs are defined at an ambient temperature of 25 ± 5, excitation voltage of 12 V D and battery of 3.6 V D. Item PG-200 PG-208 Model number No. of setting points Switching capacity Residual voltage Output conditions 101G 102G 103G 102VH 102AH 102G 103G 102VH 2 points of HI and LO (one point of HI only for the external power supply version) 30 V D 40 ma(npn open collector) 1.2 V D(When current inflow is 40 ma) Measured press LO set press. LO output ON, Measured press. HI set press. HI output ON. Switch Setting method When the SET button is pressed, HI set pressure is displayed for about 20 seconds first, then LO set pressure is displayed for about 20 seconds. Therefore, high and low pressure settings can be made by VR watching the display. Pressure setting range Switch state indication Response 000 ~ 735 000 ~ 735.000 ~ 1.000 0.00 ~ 10.00.000 ~ 1.000 0.00 ~ 10.00 3 3 Indicated by an LD display (HI or LO) when the switch output is ON. Approx. 100 ms 000 ~ 735 3 Switching hysteresis 4 Analog voltage output Additional function 4 counts maximum Voltage output: 0 ~ 1 V, Accuracy: ± 1 %F.S. (at 25 ± 5 ), Load: 1 kω minimum Low battery indication (LO AT) Accessories (for panel type only) Attachements : Half union (for a tube of φ 6 0.D.), and arb fitting (for a tube of φ 4 I.D.), one piece each. ( only) 3 : Pressure setting can be made up to 760 mmhg for 102VH and up to 760 mmhg for 102AH (Accuracy not guaranteed beyond the rated pressure.). 4 : Available only for external power type. ENVIRONMENTAL HARATERISTIS Test item Test conditions Permissible change Vibration Shock Pressure cycling Moisture resistance Amplitude 1.5 mm P-P, 10 ~ 55 Hz, 3 directions for 2 hours each (packed) 98.1 m/s 2, 3 directions for 3 times each (packed) 10 6 cycles 0 ~ Rated pressure 40, 90 ~ 95 %RH, 240 hrs. Pressure indication, switch setting and analog output (zero and span) variation: ± 1 %F.S. maximum each. (Note: No analog output for the battery type.)
M OUTLINE DIMENSIONS Unless otherwise specified, tolerance : ± 0.5 (Unit: mm) PG-200 (40) 13 27 69 ATT LH 1 2 3 4 5 6 68 PRESSURE GAUGE OPAL ELETRONIS 19 M 5 depth 5 Pressure port 15 Panel cut dimension 69.5 +0.5 0 Panel cut (1~2.5 mm) Panel board thickness 68.5 +0.5 0 <PG-200 > Electrical connection type 1 2 3 4 5 6 Voltage output PG-200 11.5 40 Electrical terminals are located inside. ATT LH PRESSURE GAUGE OPAL ELETRONIS YL X YH ORD ONNETION5~ V10 O10 ~ V24 5 6 8 9 10 11 28.5 22 ± 1 13.5 R 1/4 (PT 1/4) 13.5 ± 1 Use connecting wires AWG Pressure port 26 or thinner one. M 5 depth 6 19 M 5 Electrical connection D E F 5 6 8 9 10 11 type Grommet φ 7 Voltage output D5 ~ 10 V D10 ~ 24 V should be connected to proper terminals depending on the voltage.
~ ~ OUTLINE DIMENSIONS Unless otherwise specified, tolerance : ± 0.5 (Unit: mm) PG-208 For corrosive or liquids 11.5 40 Electrical terminals are located inside. ATT ORD ONNETION 311 PRESSURE GAUGE OPAL ELETRONIS Pressure port SUS 316 YL X YH 5 10 V O M 10 24 V 5 6 8 9 10 11 11 Diaphragm (SUS 316L) G 3/8 (PF 3/8) 28.5 SUS 316 151 Use connecting wires AWG 26 or thinner one. O ring (Fluoro rubber) (P 18) 27 Electrical connection D E F 5 6 8 9 10 11 type Voltage output Grommet φ 7 D5 ~ 10 V D10 ~ 24 V should be connected to proper terminals depending on voltage. Extra care should be taken with the diaphragm part. Do not touch the diaphragm directly to avoid damaging the diaphragm. INSIDE OF A PANEL Digital 3 1/2 digits Low battery indication ATT Polarity L H SW output indication POWER SET LO HI SPAN ZERP ON Decimal point Power SW Set SW LO setting VR HI setting VR ZERO adjustment VR SPAN adjustment VR INTERNAL ELETRIAL SHEMATIS type type Power supply circuit Pressure Sensor Main circuit Pressure Sensor Main circuit Voltage output LD LD Pressure indication Pressure indication No as to.