NFRC THERMAL PERFORMANCE TEST REPORT. Rendered to: INTERNATIONAL ARCHITECTURAL PRODUCTS, INC. DBA: UNITED STATES ALUMINUM

Similar documents
NFRC THERMAL PERFORMANCE TEST REPORT. Rendered to: UNITED STATES ALUMINUM. SERIES/MODEL: 7400 TYPE: Fixed

NFRC THERMAL PERFORMANCE TEST REPORT. Rendered to: PARAMOUNT WINDOWS CORPORATION. SERIES/MODEL: 4000 TYPE: Fixed

NFRC THERMAL PERFORMANCE TEST REPORT. Rendered to: CMI ARCHITECTURAL PRODUCTS, INC.

NFRC THERMAL PERFORMANCE TEST REPORT. Rendered to: TUBELITE, INC.

NFRC THERMAL PERFORMANCE TEST REPORT. Rendered to: NORTH EAST WINDOWS USA, INC.

NFRC THERMAL PERFORMANCE TEST REPORT. Rendered to: C.R. LAURENCE CO., INC.

NFRC THERMAL PERFORMANCE TEST REPORT. Rendered to: NU VISTA WD, INC. SERIES/MODEL: Malibu 250 T TYPE: Fixed

NFRC THERMAL PERFORMANCE TEST REPORT. Rendered to: C.R. LAURENCE CO., INC.

SHANGHAI MYLCH WINDOWS & DOORS THERMAL PERFORMANCE TEST REPORT

THERMAL PERFORMANCE TEST REPORT

Test Results: Results of the test period on 06/19/16 using the Equivalent CTS Method: Thermal transmittance at test conditions (U s ):

Report No: NCTL NFRC THERMAL TEST SUMMARY REPORT Expiration Date: 12/14/15

Report No: NCTL S NFRC THERMAL TEST SUMMARY REPORT Expiration Date: 07/14/15. Test Specimen

NFRC THERMAL TEST SUMMARY REPORT Expiration Date: 03/31/06

NFRC THERMAL TEST SUMMARY REPORT January 27, 1999 Test Specimen

AIR-INS inc. 1320, boul. Lionel-Boulet, Varennes (Quebec) J3X 1P7 Tél. : (450) Fax : (450)

ASTM C THERMAL PERFORMANCE TEST REPORT. Rendered to: UNIVERSAL PULTRUSIONS, LLC. PRODUCT: Fiberglass Door Slab

NFRC SOLAR HEAT GAIN COEFFICIENT TEST REPORT. Rendered to: CLEAR FOCUS IMAGING

Simulation Report (Revised) Rendered To: Showcase Custom Vinyl Windows 1002 Olde Towne Drive Irving, TX 75061

SIMULATION TEST REPORT NCTL E0A0

WINDOW SIMULATION REPORT

PERFORMANCE TEST REPORT. Rendered to: WORLDWIDE DOOR COMPONENTS, INC. PRODUCTS: PVC and Composite Door Jamb Material

Standard Test Method for Measuring the Steady-State Thermal Transmittance of Fenestration Systems Using Hot Box Methods 1

Determination of thermal transmittance of window (test title)

Determination of installed thermal resistance into a roof of TRISO-SUPER 12 BOOST R

Customer: Ashton Industrial Sales Ltd. South Road, Harlow Essex CM20 2AR UNITED KINGDOM. Project/Customer: Profilex HM spacer

PERFORMANCE TEST REPORT. Rendered to: VELUX AMERICA, INC. PRODUCT: SUN TUNNEL Domes TYPES: Acrylic and Polycarbonate

Hanson Overhead Garage Door Company proudly presents: Residential 400 Series

CAE 463/524 Building Enclosure Design Fall 2012

UNIT FOUR SOLAR COLLECTORS

TEST METHOD FOR THERMAL TRANSMITTANCE AND AIR INFILTRATION OF GARAGE DOORS

KM-1600SWH KM-1600SRH KM-1600SWH3 KM-1600SRH3

ASTM C STEADY-STATE HEAT FLUX MEASUREMENTS AND THERMAL TRANSMISSION PROPERTIES BY MEANS OF THE HEAT FLOW METER APPARATUS

Introduction...COMB-2 Design Considerations and Examples...COMB-3

Window air permeability measurement, watertightness and resistance to wind load (designation of the test)

CRYOGENIC CONDUCTION COOLING TEST OF REMOVABLE PANEL MOCK-UP FOR ITER CRYOSTAT THERMAL SHIELD

National Fenestration Rating Council. Incorporated. NFRC [E0A1] Procedure for Determining Fenestration Product Condensation Resistance Values

Thermal and mechanical modeling of thermal breaks in structural steel point transmittances

Vincent Barraud SOPREMA BASICS OF THERMAL INSULATION

THE EFFECTS OF CALORIMETER TILT ON THE INWARD-FLOWING FRACTION OF ABSORBED SOLAR RADIATION IN A VENETIAN BLIND

NFRC Errata and Addendum Log

Vinyl Products Pella Windows and Doors

KM-2000SWE3 KM-2000SRE3

17.01 Maxblock Sunshades by Tubelite Description

TEST OF MEASURED SOLAR HEAT GAIN VARIATION WITH RESPECT TO TEST SPECIMEN TILT

ROLLEASE ACMEDA ACOUSTICAL PERFORMANCE TEST REPORT

Winter Night. Thermos 6mm Outdoors # #

THERMAL TRANSMITTANCE OF MULTI-LAYER GLAZING WITH ULTRATHIN INTERNAL PARTITIONS. Agnieszka A. Lechowska 1, Jacek A. Schnotale 1

A L A BA M A L A W R E V IE W

NO: ISSUED: DEC. 7, 1999 REVISED: SEPT. 4, 2002 HOSHIZAKI MODULAR ICEMAKER F-2000MLF(-C) MODEL (FINAL) PARTS LIST

Reflectec Thermal Fabric & Reflectec Fiberboard

METHOD OF IN-SITU MEASUREMENT OF THERMAL INSULATION PERFORMANCE OF BUILDING ELEMENTS USING INFRARED CAMERA

REPORT NUMBER: MID-001 ORIGINAL ISSUE DATE: April 22, 2016 REVISED DATE: NA. EVALUATION CENTER Intertek 8431 Murphy Drive Middleton, WI 53562

HOSHIZAKI MODULAR CRESCENT CUBER MODEL KM-280MAE KM-280MWE (FINAL) PARTS LIST

Solar Radiation 230 BTU s per Hr/SF. Performance Glazing Coatings, Layers & Gases

SL27C SL32C. ScreenLine. Technical Catalogue. english. double-glazed unit 27 mm 32 mm

CAE 331/513 Building Science Fall 2016

NFRC Errata and Addendum Log

C1.0 HOP IN FUEL STATION BENCHMARKS PARKING SUMMARY TABLE SITE PAVING: NOTES: SITE LOCATION MAP LEGEND DESCRIPTION PROPOSED EXISTING

Solar Energy Cooking with the Sun

KM-1300SAF KM-1300SWF KM-1300SRF KM-1300SAF3 KM-1300SWF3 KM-1300SRF3

REPORT NUMBER: GZU-001 ORIGINAL ISSUE DATE:

Determining of Thermal Conductivity Coefficient of Pressed Straw (Name of test)

KEYWORDS Glazing; Window; Low E; Teflon; U-value; Shading Coefficient INTRODUCTION

BACK TO BASICS: PIPE INSULATION

T h e C S E T I P r o j e c t

CONSTRUCTION MATERIALS

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27

Eco-insulation for High Performance Daylighting. Hurricane Resistant Glazing. Blast Resistant Glazing

www. ElectricalPartManuals. com Flexitest Switch Assemblies Type FT-19R and FT-19RX INTL APPLICATION

QIRT th International Conference on Quantitative InfraRed Thermography

Pressure Measurement Single-range transmitters for general applications

SENSOR. Weather TRANSMITTERS

ISO INTERNATIONAL STANDARD. Thermal performance of windows, doors and shutters Calculation of thermal transmittance Part 1: Simplified method

AR/IA 241 LN 231 Lecture 4: Fundamental of Energy

ETS-LINDGREN ACOUSTIC RESEARCH LABORATORY OFFICIAL LABORATORY REPORT ARL-SA6956 Revision 1 ARL

of PASSIVE Europa 92 door with 44mm & 48mm glazing for Zyle Fenster UAB J. Jasinskio 16a LT Lithuania

ANSI/SPRI ES-1 Test Reports UL Classified Products

Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level

5. Thermal Design. Objective: Control heat flow to: Maintain comfortable indoor conditions

Flexitest Switch Assemblies Type FT-19R and FT-19RX Supersedes DB March 2008

1 / 17. TÜV Rheinland (Shanghai) Co., Ltd Solar/ Fuelcell Technologies. Test Report

*Refer to IBC Section , applicable when fall protection is required. Glass stresses are designed for a safety factor of of 4.0 (IBC ).

Krantz Components. Twist outlet DD-N... for ceiling installation. Air distribution systems

ISO INTERNATIONAL STANDARD

MINIATURE MICROSWITCHES - PREMIUM

The Electrodynamics of a Pair of PV Modules with Connected Building Resistance

Visit any one of our 30 locations or visit us on line at

Peltier Application Note

Calculating the heat transfer coefficient of frame profiles with internal cavities

E N L I G H T E N E D L I V I N G

Distinctive Characteristics

Building Envelope Requirements Overview Page 3-4

Slot diffusers. Slot diffusers, Round duct diffusers. Slot diffusers. Slot diffusers LD-13, LD-14

the distance of conduction (the thickness), the greater the heat flow.

QUAKE BRAKE TM MODEL QBC-12 SEISMIC SWAY BRACING KIT FEATURING

PERFORMANCE EVALUATION OF REFLECTIVE COATINGS ON ROOFTOP UNITS

Name Partner. Thermal Physics. Part I: Heat of Vaporization of Nitrogen. Introduction:

Collector test according to EN ,2:2002

THREE HOLE SPLICE CLEVIS FOR B52 Standard finishes: ZN, GRN Wt./C 126 Lbs. (57.1 kg)

Transcription:

Architectural Testing NFRC 102-2010 THERMAL PERFORMANCE TEST REPORT Rendered to: INTERNATIONAL ARCHITECTURAL PRODUCTS, INC. DBA: UNITED STATES ALUMINUM SERIES/MODEL: 7600 Projected Vent TYPE: Projecting (Awning) Summary of Results Standardized Thermal Transmittance (U-Factor) 0.45 Unit Size 59-1/8'' x 23-5/8'' (1502 mm x 600 mm) (Model Size) Layer 1 1/4" Comfort Ti-AC36 (e=0.034*, #2) Gap 0.50'' Gap, Stainless Steel Spacer (SS-D), 100% Air-Filled* Layer 2 1/4" Clear Reference must be made to Report No., dated 09/13/10 for complete test specimen description and data. 2524 E. Jensen Ave Fresno, CA 93706 phone: 559-233-8705 fax: 559-233-8360 www.archtest.com

Architectural Testing NFRC 102-2010 THERMAL PERFORMANCE TEST REPORT Rendered to: INTERNATIONAL ARCHITECTURAL PRODUCTS, INC. 200 Singleton Drive Waxahachie, Texas 75165 Report Number: Test Date: Report Date: Test Record Retention Date: 08/27/10 09/13/10 08/27/14 Test Sample Identification: Series/Model: 7600 Projected Vent Type: Projecting (Awning) Overall Size: 59-1/8'' x 23-5/8'' (1502 mm x 600 mm) (Model Size) NFRC Standard Size: 59.1" x 23.6" (1500 mm wide x 600 mm high) Test Sample Submitted by: Test Sample Submitted for: Client Validation for Initial Certification (Production Line Unit) & Plant Qualification Test Procedure: U-factor tests were performed in a Guarded Hot Box in accordance with NFRC 102-2010, Procedure for Measuring the Steady-State Thermal Transmittance of Fenestration Systems. Test Results Summary: Standardized U-factor (Ust): 0.45 Btu/hr ft 2 F CTS Method 2524 E. Jensen Ave Fresno, CA 93706 phone: 559-233-8705 fax: 559-233-8360 www.archtest.com

Architectural Testing Page 2 of 8 Test Sample Description: CONSTRUCTION Frame Vent Size (in.) Daylight Opening (in.) 59-1/8 x 23-5/8 58-3/4 x 23-1/4 N/A 54-3/4 x 19-1/4 CORNERS Coped Mitered Fasteners Sealant Screws Yes Keys & Stakes Yes MATERIAL AL AT (0.25") Color Exterior Finish Exterior Color Interior Finish Interior GLAZING METHOD Gray Anodized Gray Anodized N/A Gray Anodized Gray Anodized Exterior Glazing Information: Layer 1 Gap Layer 2 Gas Fill Method 1/4" Comfort Ti-AC36 (e=0.034*, #2) 0.50'' Gap, Stainless Steel Spacer (SS-D), 100% Air-Filled* 1/4" Clear N/A* *Stated per Client/Manufacturer N/A Non-Applicable See Description Table Abbreviations

Architectural Testing Page 3 of 8 Test Sample Description: (Continued) COMPONENTS Type Quantity Location WEATHERSTRIP Hollow bulb vinyl gasket 1 Row All members of the frame & vent. Single leaf vinyl gasket 1 Row All members of the vent. HARDWARE Muluti arm hinge 1 Each jamb. Handle with three point lock assembly 1 Bottom rail. Keeper 3 Sill. DRAINAGE None

Architectural Testing Page 4 of 8 Thermal Transmittance (U-factor) Measured Test Data Heat Flows 1. Total Measured Input into Metering Box (Qtotal) 445.18 Btu/hr 2. Surround Panel Heat Flow (Qsp) 127.72 Btu/hr 3. Surround Panel Thickness 4.00 inches 4. Surround Panel Conductance 5. Metering Box Wall Heat Flow (Qmb) 0.0437 Btu/hr ft 2 F -10.73 Btu/hr 6. EMF vs Heat Flow Equation (equivalent information) 0.0244*EMF + -1.036 7. Flanking Loss Heat Flow (Qfl) 18.72 Btu/hr 8. Net Specimen Heat Loss (Qs) 309.46 Btu/hr Areas 1. Test Specimen Projected Area (As) 9.70 ft 2 2. Test Specimen Interior Total (3-D) Surface Area (Ah) 11.83 ft 2 3. Test Specimen Exterior Total (3-D) Surface Area (Ac) 8.27 ft 2 4. Metering Box Opening Area (Amb) 53.48 ft 2 5. Metering Box Baffle Area (Ab1) 52.23 ft 2 6. Surround Panel Interior Exposed Area (Asp) 43.78 ft 2 Test Conditions 1. Average Metering Room Air Temperature (t h ) 69.80 F 2. Average Cold Side Air Temperature (t c ) -0.18 F 3. Average Guard/Environmental Air Temperature 72.01 F 4. Metering Room Average Relative Humidity 9.00 % 5. Metering Room Maximum Relative Humidity 9.05 % 6. Metering Room Minimum Relative Humidity 8.97 % 7. Measured Cold Side Wind Velocity (Perpendicular Flow) 15.62 mph 8. Measured Static Pressure Difference Across Test Specimen 0.00" ± 0.04"H 2 O Results 1. Thermal Transmittance of Test Specimen (U s ) 0.46 Btu/hr ft 2 F 2. Standardized Thermal Transmittance of Test Specimen (U st ) 0.45 Btu/hr ft 2 F

Architectural Testing Page 5 of 8 Thermal Transmittance (U-factor) Calculated Test Data CTS Method 1. Warm Side Emittance of Glass (e1) 0.84 2. Cold Side Emittance of Glass 0.84 3. Warm Side Frame Emittance 0.80 4. Cold Side Frame Emittance 0.80 5. Warm Side Sash/Panel/Vent Emittance 0.80 6. Cold Side Sash/Panel/Vent Emittance 0.80 7. Warm Side Baffle Emittance (eb1) 0.92 8. Equivalent Warm Side Surface Temperature 46.95 F 9. Equivalent Cold Side Surface Temperature 6.28 F 10. Warm Side Baffle Surface Temperature 69.73 F 11. Measured Warm Side Surface Conductance (h h ) 1.40 Btu/hr ft 2 F 12. Measured Cold Side Surface Conductance (hc) 4.94 Btu/hr ft 2 F 13. Test Specimen Thermal Conductance (Cs) 0.78 Btu/hr ft 2 F 14. Convection Coefficient (Kc) 0.30 Btu/(hr ft 2 F 1.25 ) 15. Radiative Test Specimen Heat Flow (Qr1) 164.72 Btu/hr 16. Conductive Test Specimen Heat Flow (Qc1) 144.74 Btu/hr 17. Radiative Heat Flux of Test Specimen (qr1) 16.98 18. Convective Heat Flux of Test Specimen (qc1) 14.92 19. Standardized Warm Side Surface Conductance (hsth) 1.35 20. Standardized Cold Side Surface Conductance (hstc) 5.28 21. Standardized Thermal Transmittance (Ust) 0.45 Btu/hr ft 2 F Btu/hr ft 2 F Btu/hr ft 2 F Btu/hr ft 2 F Btu/hr ft 2 F Test Duration 1. The environmental systems were started at 10:01 hours, 08/26/10. 2. The test parameters were considered stable for two consecutive four hour test periods from 21:57 hours, 08/26/10 to 05:57 hours, 08/27/10. 3. The thermal performance test results were derived from 01:57 hours, 08/27/10 to 05:57 hours, 08/27/10. The reported Standardized Thermal Transmittance (Ust) was determined using CTS Method, per Section 8.2(A) of NFRC 102.

Architectural Testing Page 6 of 8 Glazing Deflection (in): Vent Edge Gap Width Estimated center gap width upon receipt of specimen in laboratory (after stabilization) Center gap width at laboratory ambient conditions on day of testing Center gap width at test conditions 0.50 0.55 0.55 0.45 Glass collapse determined using a digital glass and air space meter The sample was inspected for the formation of frost or condensation, which may influence the surface temperature measurements. The sample showed no evidence of condensation/frost at the conclusion of the test. A calibration of the Architectural Testing Inc. 'thermal test chamber' (ICN 004287) in Fresno, California was conducted in April 2010 in accordance with Architectural Testing Inc. calibration procedure. "This test method does not include procedures to determine the heat flow due to either air movement through the specimen or solar radiation effects. As a consequence, the thermal transmittance results obtained do not reflect performances which may be expected from field installations due to not accounting for solar radiation, air leakage effects, and the thermal bridge effects that may occur due to the specific design and construction of the fenestration system opening. Therefore, it should be recognized that the thermal transmittance results obtained from this test method are for ideal laboratory conditions and should only be used for fenestration product comparisons and as input to thermal performance analyses which also include solar, air leakage and thermal bridge effects." "Ratings included in this report are for submittal to an NFRC-licensed IA for certification purposes and are not meant to be used for labeling purposes. Only those values identified on a valid Certification Authorization Report (CAR) are to be used for labeling purposes." The test sample was installed in a vertical orientation, the exterior of the specimen was exposed to the cold side. The direction of heat transfer was from the interior (warm side) to the exterior (cold side) of the specimen. ANSI/NCSL Z540-2-1997 type B uncertainty for this test was 4.69%.

Architectural Testing Page 7 of 8 Detailed drawings, data sheets, representative samples of test specimens, a copy of this report, or other pertinent project documentation will be retained by Architectural Testing, Inc. for a period of four years from the original test date. At the end of this retention period such materials shall be discarded without notice and the service life of this report by Architectural Testing will expire. Results obtained are tested values and were secured by using the designated test methods. This report does not constitute certification of this product nor an opinion or endorsement by this laboratory. Ratings included in this report are for submittal to an NFRC licensed IA for certification purposes and are not meant to be used for labeling purposes. Only those values identified on a valid Certification Authorization Report (CAR) are to be used for labeling purposes. It is the exclusive property of the client so named herein and relates only to the specimen(s) tested. This report may not be reproduced, except in full, without the written approval of Architectural Testing, Inc. For ARCHITECTURAL TESTING, INC. Tested By: Reviewed By: Simon Smeds Technician Kenny C. White Laboratory Manager Individual-In-Responsible-Charge WSS:ss Attachments (pages): This report is complete only when all attachments listed are included. Appendix-A: Appendix-B: Description Table Abbreviations (1) CTS Calibration Data (1) Appendix-C: Surround Panel Wiring Diagram (1) Appendix-D: Baffle Wiring Diagram (1) Appendix-E: Submittal Form and Drawings (10)

Architectural Testing Page 8 of 8 Revision Log Rev. # Date Page(s) Revision(s) 0 09/13/10 All Original Report Issue. Work requested by Mr. Don Willard of International Architectural Products, Inc. This report produced from controlled document template ATI 00025(a), revised 06/17/2010.

Appendix A: Description Table Abbreviations CODE Frame / Sash Types DOOR DETAILS AI Aluminum w/ Vinyl Inserts (Caps) N Not Applicable AL Aluminum AP Aluminum w/ Thermal Breaks - Partial CODE Door Type AS Aluminum w/ Steel Reinforcement EM Embossed AT Aluminum w/ Thermal Breaks - All Members ( > 0.21") FL Flush AU Aluminum Thermally Improved - All Members (0.062" - 0.209") LF Full Lite AV Aluminum / Vinyl Composite LH 1/2 - Lite AW Aluminum-clad Wood LQ 1/4 - Lite FG Fiberglass LT 3/4 - Lite PA ABS Plastic w/ All Members Reinforced RP Raised Panel PC ABS Plastic-clad Aluminum PF ABS Plastic w/ Foam-filled Insulation CODE Skin PH ABS Plastic w/ Horizontal Members Reinforced AL Aluminum PI ABS Plastic w/ Reinforcement - Interlock FG Fiberglass PL ABS Plastic GS Galvanized Steel PP ABS Plastic w/ Reinforcement - Partial ST Steel PV ABS Plastic w/ Vertical Members Reinforced WD Wood PW ABS Plastic-clad Wood VY Vinyl ST Steel VA Vinyl w/ All Members Reinforced CODE Panel VC Vinyl-clad Aluminum FG Fiberglass VF Vinyl w/ Foam-filled Insulation PL Plastic VH Vinyl w/ Horizontal Members Reinforced WP Wood - Plywood VI Vinyl w/ Reinforcement - Interlock WS Wood - Solid VP Vinyl w/ Reinforcement - Partial VV Vinyl w/ Vertical Members Reinforced CODE Sub-Structure VW Vinyl-clad Wood GS Galvanized Steel VY Vinyl ST Steel WA Aluminum / Wood composite WD Wood WD Wood VY Vinyl WV Vinyl / Wood composite WF Fiberglass/Wood Combination CODE Core Fill WC Composite/Wood Composite (Shaped vinyl/wood composite members) CH Cellular - Honeycomb CW Copper Clad Wood EP Expanded Polystyrene CO Vinyl/Wood Composite Material PI PU Polyisocyanurate Polyurethane CODE Tint Codes WP Wood - Plywood AZ Azurlite WS Wood - Solid CODE Spacer Types (See sealant) BL Blue XP Extruded Polystyrene A1 Aluminum BZ Bronze A2 Aluminum (Thermally-broken) CL Clear CODE Spacer Sealant A3 Aluminum-reinforced Polymer EV Evergreen D Dual Seal Spacer System A4 Aluminum / Wood GD Gold S Single Seal Spacer System A5 Aluminum-reinforced Butyl (Swiggle) GR Green A6 Aluminum / Foam / Aluminum GY Gray CODE Grid Description A7 Aluminum U-shaped LE Low 'e' Coating N No Muntins A8 Aluminum-Butyl (Corrugated) (Duraseal) OT Other (use comment field) G Grids between glass ER EPDM Reinforced Butyl RC Solar or Reflective Coating S Simulated Divided Lites FG Fiberglass RG Roller Shades between glazing T True Muntins GL Glass RS Silver (reflective coating) OF Organic Foam SF Suspended Polyester Film P1 Duralite SR Silver CODE Grid Size Codes PU Polyurethane Foam BG Blinds between the Glazing Blank for no grids SU Stainless Steel, U-shaped DV Dynamic Glazing-Variable 0.75 Grids < 1" CU Coated Steel, U-shaped (Intercept) DY Dynamic Glazing-NonVariable 1.5 Grids >= 1" S2 Steel (Thermally-broken) S3 Steel / Foam / Steel CODE Gap Fill Codes S5 Steel-reinforced Butyl AIR Air CODE Thermal Breaks S6 Steel U-channel w/ Thermal Cap AR2 Argon/Krypton Mixture F Foam SS Stainless Steel AR3 Argon / Krypton / Air U Urethane CS Coated Steel ARG Argon/Air V Vinyl TP Thermo-plastic CO2 Carbon Dioxide FB Fiberglass WD Wood KRY Krypton/Air O Other ZE Elastomeric Silicone Foam SF6 Sulfur Hexaflouride AB ABS ZF Silicone Foam XE2 Xenon/Krypton/Air NE Neoprene ZS Silicone / Steel XE3 Xenon/Argon/Air AI Air N Not Applicable XEN Xenon/Air N Not Applicable TS Thermo-plastic w/ stainless steel substrate N Not Applicable P Polyamide

Appendix B: CTS Calibration Data 1. CTS Test Date 03/06/10 2. CTS Size 15.00 ft 2 3. Glass Conductance 57.78 Btu/hr ft 2 F 4. CTS Core Conductance 0.33 Btu/hr ft 2 F 5. Warm Side Air Temperature 70.05 F 6. Cold Side Air Temperature -0.60 F 7. Warm Side Average Surface Temperature 56.75 F 8. Cold Side Average Surface Temperature 3.25 F 9. Convection Coefficient (Kc) 0.30 Btu/(hr ft 2 F 1.25 ) 10. Measured Cold Side Surface Conductance (hc) 4.94 Btu/hr ft 2 F 11. Measured Thermal Transmittance 0.25 Btu/hr ft 2 F

Appendix C: Surround Panel Wiring Diagram +1 +2 +3 +4 +5 +6 +7 +8

Appendix D: Baffle Wiring Diagram +1 +2 +3 +4 +5 +6 +7 +8 +9 +10 +11 +12 +13 +14 +15

Appendix E: Submittal Form and Drawings