THERMAL EMITTANCE MEASUREMENTS AT THE SwissFEL INJECTOR TEST FACILITY

Similar documents
SwissFEL INJECTOR DESIGN: AN AUTOMATIC PROCEDURE

SRF GUN CHARACTERIZATION - PHASE SPACE AND DARK CURRENT MEASUREMENTS AT ELBE*

Low slice emittance preservation during bunch compression

FURTHER UNDERSTANDING THE LCLS INJECTOR EMITTANCE*

Diagnostic Systems for Characterizing Electron Sources at the Photo Injector Test Facility at DESY, Zeuthen site

Modeling of the secondary electron emission in rf photocathode guns

Simulations of the IR/THz Options at PITZ (High-gain FEL and CTR)

Simulations of the IR/THz source at PITZ (SASE FEL and CTR)

Investigations on the electron bunch distribution in the longitudinal phase space at a laser driven RF-electron source for the European X-FEL

ASTRA simulations of the slice longitudinal momentum spread along the beamline for PITZ

LCLS Injector Prototyping at the GTF

VELA/CLARA as Advanced Accelerator Studies Test-bed at Daresbury Lab.

Experimental Optimization of Electron Beams for Generating THz CTR and CDR with PITZ

Transverse emittance measurements on an S-band photocathode rf electron gun * Abstract

THE LASER HEATER SYSTEM OF SWISSFEL

Towards a Low Emittance X-ray FEL at PSI

START-TO-END SIMULATIONS FOR IR/THZ UNDULATOR RADIATION AT PITZ

Emittance and Quantum Efficiency Measurements from a 1.6 cell S- Band Photocathode RF Gun with Mg Cathode *

LCLS Accelerator Parameters and Tolerances for Low Charge Operations

The New Superconducting RF Photoinjector a High-Average Current & High-Brightness Gun

Short Pulse, Low charge Operation of the LCLS. Josef Frisch for the LCLS Commissioning Team

Injector Experimental Progress

4 FEL Physics. Technical Synopsis

Longitudinal Measurements at the SLAC Gun Test Facility*

RF Gun Photo-Emission Model for Metal Cathodes Including Time Dependent Emission

Generation and characterization of ultra-short electron and x-ray x pulses

PAL LINAC UPGRADE FOR A 1-3 Å XFEL

Introduction to the benchmark problem

Juliane Rönsch Hamburg University. Investigations of the longitudinal phase space at a photo injector for the X-FEL

Reduction of thermal emittance of rf guns *

Alignment requirement for the SRF cavities of the LCLS-II injector LCLSII-TN /16/2014

E-886 (Piot) Advanced Accelerator Physics Experiments at the Fermilab/NICADD Photoinjector Laboratory (FNPL)

LOLA: Past, present and future operation

Development of reliable and sophisticated photo injector system and future plan

SPARCLAB. Source For Plasma Accelerators and Radiation Compton with Laser And Beam

Time resolved transverse and longitudinal phase space measurements at the high brightness photo injector PITZ

Linac Driven Free Electron Lasers (III)

Femtosecond X-ray Pulse Temporal Characterization in Free-Electron Lasers Using a Transverse Deflector. Abstract

Characterization of an 800 nm SASE FEL at Saturation

High average current photo injector (PHIN) for the CLIC Test Facility at CERN

Photoinjector design for the LCLS

SPARCLAB. Source For Plasma Accelerators and Radiation Compton. On behalf of SPARCLAB collaboration

Commissioning of the new Injector Laser System for the Short Pulse Project at FLASH

Start-to-End Simulations

What have we learned from the LCLS injector?*

A Polarized Electron PWT Photoinjector for the ILC

A Bunch Compressor for the CLIC Main Beam

X-band RF driven hard X-ray FELs. Yipeng Sun ICFA Workshop on Future Light Sources March 5-9, 2012

EXPERIMENTAL STUDIES WITH SPATIAL GAUSSIAN-CUT LASER FOR THE LCLS PHOTOCATHODE GUN*

Motivation of emission studies at PITZ

X-Band RF Harmonic Compensation for Linear Bunch Compression in the LCLS

1. Beam based alignment Laser alignment Solenoid alignment 2. Dark current 3. Thermal emittance

Dark Current at Injector. Jang-Hui Han 27 November 2006 XFEL Beam Dynamics Meeting

Photo Injector Test facility at DESY, Zeuthen site

ICFA ERL Workshop Jefferson Laboratory March 19-23, 2005 Working Group 1 summary Ilan Ben-Zvi & Ivan Bazarov

THE LCLS-II INJECTOR DESIGN*

Free-electron laser SACLA and its basic. Yuji Otake, on behalf of the members of XFEL R&D division RIKEN SPring-8 Center

Diagnostic Systems for High Brightness Electron Injectors

Design of an RF Photo-Gun (PHIN)

VARIABLE GAP UNDULATOR FOR KEV FREE ELECTRON LASER AT LINAC COHERENT LIGHT SOURCE

FEL SIMULATION AND PERFORMANCE STUDIES FOR LCLS-II

Low energy high brilliance beam characterization

arxiv: v2 [physics.acc-ph] 10 Aug 2012

Cornell Injector Performance

OPTIMIZATION OF COMPENSATION CHICANES IN THE LCLS-II BEAM DELIVERY SYSTEM

Emittance and photocathodes

Femto-second FEL Generation with Very Low Charge at LCLS

Status of linear collider designs:

Length of beam system = 910m. S. Reiche X var = ~50m ~ 650m / Y. Kim FEL-KY ~150m. ~60m. LaserHutch2 (access during operation)

Flexible control of femtosecond pulse duration and separation using an emittance-spoiling foil in x-ray free-electron lasers

Intrinsic beam emittance of laser-accelerated electrons measured by x-ray spectroscopic imaging

Linac optimisation for the New Light Source

Linac Based Photon Sources: XFELS. Coherence Properties. J. B. Hastings. Stanford Linear Accelerator Center

SPPS: The SLAC Linac Bunch Compressor and Its Relevance to LCLS

Electron Linear Accelerators & Free-Electron Lasers

New Electron Source for Energy Recovery Linacs

Diagnostics at the MAX IV 3 GeV storage ring during commissioning. PPT-mall 2. Åke Andersson On behalf of the MAX IV team

Tomographic transverse phase space measurements at PITZ.

Developments for the FEL user facility

Parameter selection and longitudinal phase space simulation for a single stage X-band FEL driver at 250 MeV

LCLS-II Conceptual Design Review. 6 Accelerator

Experimental Measurements of the ORION Photoinjector Drive Laser Oscillator Subsystem

Brightness and Coherence of Synchrotron Radiation and Free Electron Lasers. Zhirong Huang SLAC, Stanford University May 13, 2013

Expected properties of the radiation from VUV-FEL / femtosecond mode of operation / E.L. Saldin, E.A. Schneidmiller, M.V. Yurkov

DESIGN STUDY OF LCLS CHIRP-CONTROL WITH A CORRUGATED STRUCTURE

Electron Spectrometer for FLASHForward Plasma-Wakefield Accelerator

OPERATING OF SXFEL IN A SINGLE STAGE HIGH GAIN HARMONIC GENERATION SCHEME

Dipole current, bending angle and beam energy in bunch compressors at TTF/VUV-FEL

ATTOSECOND X-RAY PULSES IN THE LCLS USING THE SLOTTED FOIL METHOD

Introduction. Thermoionic gun vs RF photo gun Magnetic compression vs Velocity bunching. Probe beam design options

X-band Experience at FEL

Microbunching Workshop 2010 March 24, 2010, Frascati, Italy. Zhirong Huang

Accelerator Activities at PITZ

LCLS Injector Straight Ahead Spectrometer C.Limborg-Deprey Stanford Linear Accelerator Center 8 th June 2005

TECHNICAL ADVISORY COMMITTEE (TAC) REPORT 3. May 19-20, 2000

INVESTIGATIONS OF THE DISTRIBUTION IN VERY SHORT ELECTRON BUNCHES LONGITUDINAL CHARGE

Short Wavelength SASE FELs: Experiments vs. Theory. Jörg Rossbach University of Hamburg & DESY

MaRIE. MaRIE X-Ray Free-Electron Laser Pre-Conceptual Design

Initial measurements of the UCLA rf photoinjector

Laser acceleration of electrons at Femilab/Nicadd photoinjector

Transcription:

THERMAL EMITTANCE MEASUREMENTS AT THE SwissFEL INJECTOR TEST FACILITY E. Prat, S. Bettoni, H. H. Braun, M. C. Divall, R. Ganter, T. Schietinger, A. Trisorio, C. Vicario PSI, Villigen, Switzerland C. P. Hauri, EPFL, Lausanne, Switzerland and PSI, Villigen, Switzerland Abstract In a laser-driven RF gun the ultimate limit of the beam emittance is the transverse momentum of the electrons as they exit the cathode, the so-called intrinsic or thermal emittance. In this contribution we present measurements of the thermal emittance at the SwissFEL Injector Test Facility for electron beam charges down to a few tens of fc. We have studied the dependence of thermal emittance and quantum efficiency on the laser wavelength, the RF-gun gradient and the cathode material (copper and cesium telluride). INTRODUCTION The electron beam emittance is of great importance for Free-Electron Laser (FEL) facilities. First, transversely coherent FEL radiation is generated if ε n /γ λ/4π, where ε n is the normalized beam emittance, γ is the Lorentz factor and λ is the FEL radiation wavelength. This condition entails that by reducing the normalized emittance the final beam energy can be decreased, which translates into a more compact and affordable accelerator. Second, for a given beam energy, a smaller emittance implies a higher radiation power and a shorter undulator beamline to reach FEL saturation. As accelerator technology advances and the emittance of the electron source is preserved downstream of the injector, the source becomes a significant contributor to the final emittance and brightness of the electron beam. The intrinsic or thermal emittance, which is proportional to the transverse momentum of the electrons exiting the cathode, is related to the initial kinetic energy or effective temperature of the electrons. The thermal emittance for both metal and semiconductor photo-cathodes can be expressed as [1, 2]. ε th = σ l φl φ e 3m c 2, (1) where φ l is the laser photon energy, σ l is the RMS laser beam size, m c 2 is the electrons rest mass energy, and φ e is the effective work function. We call ε th /σ l the normalized thermal emittance, expressed in nm/mm, as it is independent of the laser beam size. We note that the above expression is correct if tilted-surface effects related to the surface roughness of the cathode are negligible [3]. To illustrate the effect of the thermal emittance on the final FEL performance, Fig. 1 shows the dependence of the FEL power on the normalized thermal emittance for the 2 pc charge operation mode of SwissFEL [4]. For each eduard.prat@psi.ch 97 Normalized Emittance [nm] 24 22 2 18 16 14 12 4 5 6 7 8 9 1 Thermal Emittance / RMS laser beam size [nm/mm] Figure 1: Relative FEL power as function of the normalized thermal emittance. Normalized core slice emittance is simulated for the 2 pc charge operation mode of SwissFEL for different normalized thermal emittance values. The corresponding normalized emittance for optimized laser beam size (red circles) is then used to calculate the relative FEL power (green triangles). normalized thermal emittance value we performed numerical simulations to optimize the emittance at the end of the injector, from which the FEL power was calculated. For instance, the FEL power increases by about 25% for a normalized thermal emittance reduction from 6 nm/mm to 4 nm/mm. The effective work function is defined as the material work function φ w, reduced by the Schottky effect φ s [5]: e φ e = φ w φ s = φ w 3 βe c (ϕ), (2) 4πε where e is the charge of the electron, ε is the vacuum permittivity, β is the local field enhancement factor that depends on the cathode surface properties, and E c (ϕ) is the applied field on the cathode at the injection phase ϕ. When E c (ϕ) varies in a small range, the quantum efficiency (QE) of a metal photo-cathode is linked to the laser photon energy and the effective work function as follows [1, 6]: QE (φ l φ e ) 2. (3) Equations 2 and 3 allow the determination of the effective work function of the employed cathodes directly from measurements in the RF gun in two independent ways: by measuring the emitted charge as a function of the injection 1.9.8.7.6.5.4 Relative FEL Power

S-band Booster Linac X-band Cavity Transverse Deflecting Structure Emittance Measurement Screen S-band RF-Gun Screen Monitor Screen Monitor + BPM Dipole Solenoid Quadrupole RF Structure Bunch Compressor Diagnostics Section Figure 2: Schematic layout of the SwissFEL Injector Test Facility (not to scale). The total length is about 6 m. phase (Schottky scan) and as a function of the laser energy (wavelength scan). Extensive worldwide research and development have been performed in the last years to measure the thermal emittance for metal and semiconductor photo-cathodes, see for example Refs. [6 1]. We have experimentally studied at the SwissFEL Injector Test Facility [11] the normalized thermal emittance and QE dependence on the laser wavelength λ l (φ l = hc/λ l ), the RF field at the cathode E c, and the photo-cathode material (related to φ w ). These studies are presented for copper and cesium telluride. We note that most of the results presented in this conference contribution will soon be published in a peer-reviewed journal [12]. THE SwissFEL INJECTOR TEST FACILITY The SwissFEL Injector Test Facility is the principal test bed and demonstration plant for the SwissFEL project, which is presently under construction and aims at realizing a hard- X-ray FEL by 217. Figure 2 shows a sketch of the SwissFEL Injector Test Facility. Electron bunches of charges between 1 pc and 2 pc are generated in a 2.6-cell standing-wave S-band RF photoinjector gun, originally developed for high-current operation at the CLIC test facility (CTF) at CERN [13]. There are two gun drive lasers. The main one is based on a Ti:Sapphire chirped pulse amplification system [14], which allows the variation of the 3rd harmonic emission between 26 and 28 nm. This is further extended by the use of an optical parametric amplifier (OPA) and a conversion stage to 25 31 nm. The second laser system is a compact, turn-key Nd:YLF amplifier, with a fixed wavelength of 262 nm. A longitudinal Gaussian profile of 9.9 ps FWHM is used for the measurements presented here and a selection of different size circular apertures cut the central homogeneous part of the laser beam, which is imaged onto the cathode for each wavelength at close to normal incidence. The total beam energy at the gun exit is 7.1 MeV. A solenoid close to the gun cavity is used for initial focusing. Additional individually powered windings inside the gun solenoid allow for correction of normal- and skewquadrupole field components. Four S-band accelerating structures bring the beam energy up to the nominal value of 25 MeV. Additional solenoid magnets around these structures allow for further control of the transverse optics. After some space, which is used for an X-band linearizing system and a bunch-compressor chicane, an S-band transverse deflecting cavity is used for longitudinally resolved measurements such as bunch length and slice emittance. A dedicated beam diagnostic section downstream of the deflecting cavity allows us to characterize the accelerated beam. Several quadrupole magnets and beam screens measuring the transverse beam profile are available for emittance measurements. The final beam energy is measured by a spectrometer at the end of the diagnostic section. More details on the SwissFEL Injector Test Facility can be found in Ref. [11]. MEASUREMENT PROCEDURES When the emittance measurements are performed with sufficiently low charge to avoid space charge effects, the emittance of a selected longitudinal slice of the bunch corresponds to the thermal emittance. In our case we choose the central slices of the bunch, what we call the core slice emittance. The normalized thermal emittance ε th /σ l can be reconstructed by measuring the thermal emittance as a function of the RMS laser beam size, which is varied by changing the laser aperture. It is crucial to establish a reliable and high-resolution method to be able to precisely measure the thermal emittance of the electrons. Core slice emittance measurements are performed by streaking the bunch and visualizing it on a high-resolution YAG screen [15] at the high energy section of the machine. We can streak the beam either with a RF transverse deflector or by introducing dispersion to an energy-chirped beam. The normalized emittance resolution is about 2 3 nm for a final beam energy of 25 MeV. The longitudinal resolution is about 13 fs when the transverse deflector is used. With the dispersion method we can resolve more than 5 slices per RMS bunch length (if the RMS energy chirp of the beam is 1%). The statistical and systematic errors of the emittance are estimated to be below the 5% level. A more detailed description of the slice emittance measurements can be found in Refs. [16, 17]. The YAG screen has allowed measurements for bunch charges of 1 pc and less, where space charge effects are negligible for our laser beam sizes. The critical surface charge density in our case is 3 pc/mm 2 at 5 MV/m field on the cathode with a 9.9 ps FWHM pulse and has been 971

Normalized emittance [nm] 6 5 4 3 2 1 Q = 4.7 pc Q = 2.8 pc Q = 1.5 pc Q = 1. pc Q =.7 pc 1 5 5 1 slice index Figure 3: Measured slice emittance as a function of bunch charge to find the space-charge limit. Measurements for a bunch charge of 1 pc and less give the same core slice emittance values within the accuracy of the measurement, while at higher charge the presence of a space charge effect is clearly visible. identified by reducing the bunch charge at fixed laser beam size until the emittance was no longer reduced, as shown in Figure 3. Once the space-charge limit is found, the charge surface density is kept constant during the aperture scan to avoid space charge effects. The QE is measured by recording the charge at a calibrated beam position monitor 2.6 m downstream of the gun while changing the laser intensity. MEASUREMENT RESULTS We used four cathodes for our measurements, two made of pure copper, labeled Cath 3 and Cath 19, and two coated with cesium telluride labeled Cath 13 and Cath 8. The cesium telluride cathodes are prepared by depositing about 15 nm of tellurium and about 25 nm of cesium on a copper cathode. All the photocathodes were mounted in a load-lock chamber. More details on the cathode preparation can be found in Ref. [18]. We measured the dependence of the thermal emittance on the laser wavelength for the copper cathode Cath 3 and the influence of the gun gradient for the copper cathode Cath 19. The wavelength dependence measurements were carried out with the Ti:Sapphire laser, while all the rest of the measurements presented here were performed with the Nd:YLF laser. Laser Wavelength Figure 4 shows the core slice emittance measurements as a function of the laser beam size (aperture scan) for two different wavelengths (26.1 nm and 267.6 nm). We observed a linear growth of the normalized thermal emittance as a function of the laser beam size (bottom plot of Fig. 4). This is in contradiction with Eq. 1, but can be explained by our present gun design, which exposes the 972 Core slice emittance [nm] Core slice emittance / laser size [nm/mm] 35 3 25 2 15 1 5 = 547±1 nm/mm (λ = 26.1nm) = 58±35 nm/mm (λ = 267.6nm).5.1.15.2.25.3 RMS laser beam size [mm] 13 12 11 1 9 8 7 6 5.5.1.15.2.25.3 RMS laser beam size [mm] Figure 4: Core slice emittance as a function of the laser beam size for two laser wavelengths 26.1 nm (dashed blue) and 267.6 nm (red solid) for cathode Cath 3.. electron beam to a quadrupole field component due to noncoaxial RF feeds from opposing sides. Indeed, the inhomogeneity of the cathode was ruled out as an explanation by measuring the core slice emittance at the smallest aperture, while moving the laser beam across the cathode. The nonlinear dependence of the asymmetric field in the gun was verified by aperture scans at different gun gradients (see next subsection). Taking the quadratic component into account the normalized thermal emittance can be determined as the extrapolation of the quadratic fit to an infinitely small laser beam size. The normalized thermal emittance corresponds to the linear term of a second-order fit to the emittance data, which gave 547±1 nm/mm for a wavelength of 26.1 nm and 58±35 nm/mm for a wavelength of 267.6 nm. One month later we performed measurements at four different wavelengths using the same cathode (Cath 3 ). These measurements were realized with a charge of 1 pc and at the smallest laser aperture, corresponding to about 5 µm RMS laser beam size on the cathode. We note that measurements performed with only the smallest aperture overestimate the normalized thermal emittance by 1 2%. We measured the QE for different laser wavelengths, as shown in Fig. 5. The measurements were taken with the Ti:sapphire and the OPA, covering a wavelength range of 248 31 nm. By using Eq. 3 the best fit found for Cath 3 corresponds to an effective work function of 3.93±.3 ev (see inset of Fig. 5).

Figure 5: QE as a function of wavelength with cathode Cath 3. Measurements were performed with both the OPA (black points) and the 3rd harmonic of the Ti:sapphire laser (blue stars). The fit based on Eq. 3 (inset) gives an effective work function of 3.93 ev (red line). Alternatively we estimated the effective work function by performing a Schottky scan, i.e., by measuring the emitted charge as a function of the gun phase. By using Eqs. 2 and 3 and fitting the points around the operational phase, the best fit was found with a work function of 4.56 ev for this cathode, giving an effective work function of 4.6±.9 ev. This value is close to the one from the wavelength scan. A Schottky scan done at the same time of the measurements shown in Fig. 4 gave an effective work function of 4.33±.1 ev. Figure 6 summarizes the thermal emittance measurements performed as a function of the laser wavelength. There is a good agreement between the thermal emittance determined from the core slice emittance measurements and from the wavelength and Schottky scans. Gun Gradient Figure 7 shows an aperture scan measurement for the copper cathode Cath 19 for three different gun gradients corresponding to the following fields on the cathode E c (ϕ): 49.4 MV/m (nominal value), 34.8 MV/m and 16.4 MV/m. As expected from the RF-induced effect, the quadratic component decreased as a function of the gradient: it was 716±84 nm/mm 2 at 49.9 MV/m, 58±137 nm/mm 2 at 34.8 MV/m, and 321±15 nm/mm 2 at 16.4 MV/m. The fitted normalized thermal emittances diminished for lower field on the cathode, following the dependence indicated in Eqs. 1 and 2: the normalized thermal emittance was 428±16 nm/mm at 49.9 MV/m, 37±25 nm/mm at 34.8 MV/m, and 346±25 nm/mm at 16.4 MV/m. For the lowest gun gradient it was possible to measure the slice emittance for a total bunch charge of about 3 fc. This was possible thanks to the high sensitivity of our profile monitor and due to the smaller amount of dark current produced by the gun with the lower RF gradient. The measurement for this ultra-low charge is shown in Figure 8. The core slice emittance was below 25 nm. This measurement was done Figure 6: Normalized thermal emittance as a function of wavelength for cathode Cath 3. Measurements with the smallest aperture below the space charge limit, at 1 pc (blue squares). Reconstructed thermal emittance calculated from the effective work functions determined from the QE measurements as a function of wavelength shown in Fig. 4 (cyan solid) and from the Schottky measurements (cyan dashed). Two points derived from the aperture scan a month earlier shown on Fig. 4 (red dots) with the reconstruction from the Schottky scan performed at the same time (orange dashed). Core slice emittance [nm] Core slice emittance / laser size [nm/mm] 25 2 15 1 5 E c = 49.9 MV/m = 428±16 nm/mm E c = 34.8 MV/m = 37±25 nm/mm E c = 16.4 MV/m = 346±25 nm/mm.5.1.15.2.25.3.35 Laser rms beam size [mm] 75 7 65 6 55 5 45 4 35 3.5.1.15.2.25.3.35 Laser rms beam size [mm] Figure 7: Core slice emittance as a function of beam size for three different fields on the cathode. The nonlinear effect was strongly reduced at lower field and the normalized thermal emittance varied as expected from theory. 973

3 1 1 25 Normalized emittance [nm] 2 15 1 QE 1 2 1 3 1 4 Cu (3) Cu (19) Cs 2 Te (13) Cs 2 Te (8) 5 2 1 1 2 t [ps] Figure 8: Normalized slice emittance in the horizontal plane for a bunch charge of 3 fc (magenta). The error bars are obtained by error propagation of the statistical beam-size errors. The longitudinal bunch charge profile is shown in gray bars. by employing the smallest aperture, corresponding to about 5 µm RMS laser beam size at the cathode. Cathode Material We have tested each of the two cesium telluride cathodes for one week of operation. The thermal emittance of both cathodes was measured with aperture scans. For the cesium telluride cathode Cath 8 only measurements at the three smallest laser apertures were considered to be valid, due to the inhomogeneities of the QE outside the cathode center. The value of the thermal emittance for the cesium telluride cathodes Cath 13 and Cath 8 was 713±88 nm/mm and 549± 29 nm/mm, respectively. We measured the thermal emittance for the copper cathode Cath 19 with the same machine conditions as when we performed the measurement with the cesium telluride Cath 8. The thermal emittance in this case was 43±2 nm/mm, a value about 25% lower than for cesium telluride. We have performed, for the two photo-cathode materials (with Cath 3 and Cath 13 ), an emittance optimization for an electron bunch with a 2 pc beam charge. We have achieved a slice emittance of about 2 nm for copper [16] and of about 25 nm for cesium telluride. Again, the degradation of the emittance when moving from copper to cesium telluride is about 25%. Figure 9 shows the QE evolution of all the four cathodes tested at the SwissFEL Injector Test Facility. The copper cathodes were operated for several months (Cath 3 for about 5 months and Cath 19 for about 18 months), while the two cesium telluride cathodes (Cath 13 and Cath 8 ) could be tested only for one week each. The copper cathodes show a stable value of the QE around the 1 4 level. Both cesium telluride cathodes provided a QE of about 2% at the beginning of their operation. Whereas on the third day of operation the QE of Cath 13 suddenly dropped to about 2 1 3, the QE 974 1 5 1 2 1 1 1 1 1 1 2 1 3 Time [days] Figure 9: QE evolution of the four photocathodes tested at the SwissFEL Injector Test Facility, two copper (Cath 3 and Cath 19 ) and two cesium telluride (Cath 13 and Cath 8 ). of Cath 8 stayed above 2% for the whole week. The reason for the QE deterioration of Cath 13 is not understood. For the copper cathodes the QE, measured with the smallest available laser beam size, varied by about 15% across the area of measurements shown here. The cesium telluride cathodes were less homogeneous, with QE changing by up to a factor of two. CONCLUSION Table 1 displays all the normalized thermal emittance measurements presented in this contribution. To our knowledge, this is the first time that measurements for copper and cesium telluride are performed under the same conditions and that thermal emittance measurements agree well with theoretical expectations [1, 2]. Moreover, our measured normalized thermal emittances follow the expected dependence on the laser wavelength and field at the cathode: the emittance is smaller for longer wavelengths (ε th /σ l φ 1/2 ) and l for reduced field on the cathode (ε th /σ l Ec 1/4 ). We have verified, as suggested by Ref. [1], that a longer wavelength provides a smaller thermal emittance but gives also a lower QE. We have shown that the thermal emittance can be estimated from Schottky scans (charge as a function of the RF phase) or wavelength scans (charge as a function of the laser wavelength). Cesium telluride provides a QE which is about two orders of magnitude higher than for the standard copper cathodes, while the emittance deterioration is only about 25%. This indicates that cesium telluride could be a viable alternative for SwissFEL. For a firm conclusion, however, more work on improving the surface homogeneity as well as long-term operation tests to evaluate the QE evolution with time are still needed. For a reduced field at the cathode of 16.4 MV/m we have measured a normalized thermal emittance of about 35 nm/mm. This is, to our knowledge, the smallest normal-

Table 1: Measured Normalized Thermal Emittances at the SwissFEL Injector Test Facility Label Material Measurement Normalized thermal Laser Field on the day emittance [nm/mm] wavelength [nm] cathode [MV/m] Cath 3 copper 31-1-212 547±1 26.1 49.9 copper 3-1-212 58±35 267.6 49.9 Cath 19 copper 25-9-213 428±16 262. 49.9 copper 25-9-213 37±25 262. 34.8 copper 27-9-213 346±25 262. 16.4 copper 4-4-214 43±2 262. 49.9 Cath 13 cesium telluride 28-1-213 713±88 262. 49.9 Cath 8 cesium telluride 4-4-214 549±29 262. 49.9 ized thermal emittance ever measured in an accelerator. The experimental verification of such small values was made possible through our reliable, high-resolution measurement procedure. ACKNOWLEDGMENTS We would like to thank the Beam Diagnostics team of PSI, in particular Rasmus Ischebeck, for developing and implementing the SwissFEL profile monitor used in our measurements. We acknowledge the extensive contributions of all the other PSI expert groups and the SwissFEL team to the construction and operation of the SwissFEL Injector Test Facility. We finally thank Masamitsu Aiba, Florian Müller, Sven Reiche and Mattia Schär for fruitful discussions that helped to improve the quality of the manuscript. REFERENCES [1] D. H. Dowell and J. Schmerge, Phys. Rev. ST Accel. Beams 12, 7421 (29). [2] K. Flöttmann, TESLA FEL Report 1997-1 (1997). [3] D. H. Dowell, in Photocathode Physics for Photoinjectors Workshop, Ithaca, USA (212). [4] R. Ganter (ed.), PSI Report 1-4 (212). [5] Z. M. Yusof, M. E. Conde, and W. Gai, Phys. Rev. Lett. 93, 11481 (24). [6] H. J. Qian et al., Phys. Rev. ST Accel. Beams 15, 412 (212). [7] D. Sertore, D. Favia, P. Michelato, L. Monaco, and P. Pierini, Proc. EPAC 4, Lucerne, Switzerland, 48 41 (24). [8] Y. Ding et al., Phys. Rev. Lett. 12, 25481 (29). [9] F. Stephan et al., Phys. Rev. ST Accel. Beams 13, 274 (21). [1] C. P. Hauri et al., Phys. Rev. Lett. 14, 23482 (21). [11] M. Pedrozzi (ed.), PSI Report 1-5 (21). [12] M. Divall et al., to be published. [13] R. Bossart and M. Dehler, Proc. EPAC 96, Sitges, Spain 1544-1546 (1996). [14] A. Trisorio, P. M. Paul, F. Ple, C. Ruchert, C. Vicario, and C. P. Hauri, Optics Express 19, 2128 (211). [15] R. Ischebeck and E. Prat, to be published. [16] E. Prat et al., Proc. FEL 13, New York, NY, USA, 2 24 (213). [17] E. Prat and M. Aiba, Phys. Rev. ST Accel. Beams 17, 3281 (214). [18] R. Ganter et al., these Proceedings Proc. 36th Int. Free- Electron Laser Conf., Basel, 214, MOA2 975