Deutschen Kalibrierdienst D-K

Similar documents
The Accredited Calibration Certificate for Laboratory Balances Overview, Definitions, Information

Annex to the Accreditation Certificate D-K according to DIN EN ISO/IEC 17025:2005

Physikalisch-Technische Bundesanstalt

TRACEABILITY STRATEGIES FOR THE CALIBRATION OF GEAR AND SPLINE ARTEFACTS

The Program. Wear measurement Page 5. Inspection of parts Page 6. Online certificate Page 7. DKD-calibration Page 8. Deviation analysis Page 11

TFI Report Impact Sound Insulation

Certified Reference Material

TFI Report Impact Sound Insulation

Calibration of measuring instruments and standards for roughness measuring technique

Guideline DKD-R 4-2. Sheet 3. Edition 7/2011.

ISO/BIPM Guide: Uncertainty of measurement 1

Achieving traceability of industrial computed tomography

g/cm³ DAkkS Calibration Laboratory for Temperature and Density High-precision calibration for temperature and density

First International Involute Gear Comparison

Calibration of Temperature Block Calibrators

A SPRT Intercomparison at Hg, TPW, Ga, Sn and Zn ITS-90 Fixed Points between PTB and LATU with PTB as Pilot Laboratory

Withdrawn at December 31, Guideline DKD-R 5-7. Calibration of Climatic Chambers DEUTSCHER KALIBRIERDIENST

Revision of CMM performance specifications

Certification of a High Capacity Force Machine for Testing of Load Cells According to OIML R60

ENG56 DriveTrain. Good practice guide. for surface parameter measurement strategies for form and diameter measurements for large bearings

DEUTSCHER KALIBRIERDIENST

EA-10/13. EA Guidelines on the Calibration of Temperature Block Calibrators. Publication Reference PURPOSE

Physikalisch- Technische Bundesanstalt

SAMPLE. Accuracy Calibration Certificate. Instrument Type: EURAMET cg-18 v. 4.0 Sample ACC ISO17025 WI v.1.0

INVESTIGATION OF THE CALIBRATION CAPABILITIES OF A 1 KN M AND 10 KN M REFERENCE CALIBRATION MACHINE

T e c h n i c a l L e x i c o n

CERTIFICATE OF CALIBRATION

Version 4.0 (09/2017) Version 3.0 (02/2015) Version 2.0 (03/2011) Version 1.0 (07/2007) EURAMET e.v. Bundesallee 100 D Braunschweig Germany

CALIBRATION CERTIFICATE # 503

The Fundamentals of Moisture Calibration

Auftrags-Nr.: Order No.: Auftragsdatum: Order date: LG Electronics Inc. 168, Suchul-daero, Gumi-si, Gyeongsangbuk-do, 39368, Korea

TEMPERATURE COMPENSATION DURING CMM INSPECTION

MEASUREMENT UNCERTAINTY OF ROTATING TORQUE TRANSDUCERS WHEN USED IN PARTIAL LOAD RANGES

Certificate of Accreditation to ISO/IEC 17025:2005

Sonic Anemometer Classification

CMM Uncertainty Budget

Document No: TR 12 Issue No: 1

CERTIFICATE OF CALIBRATION

Course: Technology II Training course topic: Metrology

SIM Regional Comparison on. The Calibration of Internal and External Diameter Standards SIM.L-K FINAL REPORT July 2012

EA Guidelines on the Calibration of Temperature Indicators and Simulators by Electrical Simulation and Measurement

Guide for volume determination within the scope of reference measurement procedures in medical reference measurement laboratories, Part 1

CERTIFICATE OF CALIBRATION

SAMPLE. Accuracy Calibration Certificate. Mettler Toledo 1900 Polaris Parkway Contact: Instrument Type: EURAMET cg-18 v. 4.0 Sample ACC WI v.1.

DELTA Test Report. Measurement of Sound Absorption for AqFlex ON, one Sample as a discrete Object. Performed for Flex Acoustics

Uncertainty evaluation for coordinate metrology by intelligent measurement

m 001. Chi Mei Corporation 59-1, San Chia, Jen Te, Tainan City 71702, Taiwan, R.O.C. TÜV Rheinland (Shanghai) Co., Ltd.

Quality assurance for sensors at the Deutscher Wetterdienst (DWD)

Accuracy Calibration Certificate

Evaluating the functionality of Eppendorf BioPhotometer and Eppendorf BioSpectrometer using a Secondary UV-VIS Filter Set

CERTIFICATE OF CALIBRATION

Uncertainty of Calibration. Results in Force Measurements

Quality assurance for sensors at the Deutscher Wetterdienst (DWD)

Measurement Uncertainty Principles and Implementation in QC

Uncertainty of the Measurement of Radial Runout, Axial Runout and Coning using an Industrial Axi-Symmetric Measurement Machine

Surface Roughness - Standards and Uncertainty R. Krüger-Sehm and L. Koenders

a Chi Mei Corporation 59-1, San Chia, Jen Te, Tainan City 71702, Taiwan, R.O.C. ACRYLONITRILE-BUTADIENE-STYRENE COPOLYMER

d 001. Formosa Chemicals & Fibre Corporation 201, Tung Hwa N. Rd., Taipei, Taiwan, R.O.C. TÜV Rheinland Hong Kong Ltd.

Correct Traceability in Flexible and Complex Dimensional Metrology. Uncertainty in coordinate metrology: - Needs - Standards.

Metrological Characterization of a Primary Vickers Hardness Standard Machine - NIS Egypt

Mason Technology Ltd

Mason Technology Ltd

ISO INTERNATIONAL STANDARD

Calibration and verification: Two procedures having comparable objectives and results

p Chi Mei Corporation 59-1, San Chia, Jen Te, Tainan City 71702, Taiwan, R.O.C. ACRYLONITRILE-BUTADIENE-STYRENE COPOLYMER

Available online at ScienceDirect. Andrej Godina*, Bojan Acko

EA 4/02. Expression of the Uncertainty of Measurement in Calibration. Publication Reference

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

q Chi Mei Corporation 59-1, San Chia, Jen Te, Tainan City 71702, Taiwan, R.O.C. ACRYLONITRILE-BUTADIENE-STYRENE COPOLYMER

Measurement of sound absorption coefficient for Fraster felt SpaceCover

R SANAS Page 1 of 7

The new Closed Loop pigsar and its projected CMC. Jos van der Grinten, Detlef Vieth, Bodo Mickan

Comparison of Results Obtained from Calibration of a Measuring Arm Performed According to the VDI/VDE, ASME and ISO Standards

Accuracy Assessment. Bostomatic 32GS. for. Thomas Keating Ltd. March 2009

SCOPE OF ACCREDITATION

EA-10/14. EA Guidelines on the Calibration of Static Torque Measuring Devices. Publication Reference PURPOSE

AM Metrology at NPL. Stephen Brown. Tuesday 8 th December 2015

This document is a preview generated by EVS

DELTA Test Report. Measurement of sound absorption coefficient for 15 mm Fraster felt Plus acoustic panels with mounting depth 45 mm

Appendix B1. Reports of SMU

Morehouse. Edward Lane, Morehouse Instrument Company 1742 Sixth Ave York, PA PH: web: sales:

TFI Report Sound Absorption Impact Sound Insulation

Summary. The basic principles of the simulation technique SERT

BHARATHIDASAN ENGINEERING COLLEGE, NATTRAMPALLI. DEPARTMENT OF MECHANICAL ENGINEERING FAQ

Determination of Pitch Diameter of Parallel Thread Gauges by Mechanical Probing

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Bilateral comparison on micro-cmm artefacts. between PTB and METAS. Final report

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Benefits/Application. Very high-cycle fatigue resistant up to 100 % of nominal load. Extremely robust against side forces and bending moments

A laser metroscope for the calibration of setting rings

CERTIFICATE OF ANALYSIS

Annex A Procedure for Determining the Uncertainty of Coordinate Measurement Using Multiple Method

CERTIFICATE OF ANALYSIS

Operator's Manual. optris BR 400. Calibration source

A61-02 CALA Guidance on Traceability Revision 1.2 October 15, 2012

Metallic materials Brinell hardness test. Part 3: Calibration of reference blocks

TFI Report Sound Absorption Impact Sound Insulation

Intercomparison Balances

Metrology Prof. Dr Kanakuppi Sadashivappa Bapuji Institute of Engineering and Technology Davangere. Lecture 26 Measurement of Gear Elements

PTB S 16.5 MN HYDRAULIC AMPLIFICATION MACHINE AFTER MODERNIZATION

Transcription:

akkreditiert durch die / accredited by the Deutsche Akkreditierungsstelle GmbH als Kalibrierlaboratorium im / as calibration laboratory in the Deutschen Kalibrierdienst Kalibrierschein Kalibrierzeichen Calibration certificate Calibration mark Gegenstand Object Hersteller Manufacturer Typ Type IC-Artefact A/B für Profil, Flankenlinie, Teilung, Rundlauf und M dk FRENCO GmbH Jakob-Baier-Straße 3 90518 Altdorf Fabrikat/Serien-Nr. Serial number 04711 00 01 00 Auftraggeber Customer d = 105.000 mm; ß = 0, 20 r + l Musterkunde Auftragsnummer Order No. 20154711 Anzahl der Seiten des Kalibrierscheines Number of pages of the certificate Datum der Kalibrierung Date of calibration 7 16.03.2015 Dieser Kalibrierschein dokumentiert die Rückführung auf nationale Normale zur Darstellung der Einheiten in Übereinstimmung mit dem Internationalen Einheitensystem (SI). Die DAkkS ist Unterzeichner der multilateralen Übereinkommen der European co-operation for Accreditation (EA) und der International Laboratory Accreditation Cooperation (ILAC) zur gegenseitigen Anerkennung der Kalibrierscheine. Für die Einhaltung einer angemessenen Frist zur Wiederholung der Kalibrierung ist der Benutzer verantwortlich. This calibration certificate documents the traceability to national standards, which realize the units of measurement according to the International System of Units (SI). The DAkkS is signatory to the multilateral agreements of the European co-operation for Accreditation (EA) and of the International Laboratory Accreditation Cooperation (ILAC) for the mutual recognition of calibration certificates. The user is obliged to have the object recalibrated at appropriate intervals. Dieser Kalibrierschein darf nur vollständig und unverändert weiterverbreitet werden. Auszüge oder Änderungen bedürfen der Genehmigung sowohl der Deutschen Akkreditierungsstelle GmbH als auch des ausstellenden Kalibrierlaboratoriums. Kalibrierscheine ohne Unterschrift haben keine Gültigkeit. This calibration certificate may not be reproduced other than in full except with the permission of both the Deutsche Akkreditierungsstelle GmbH and the issuing laboratory. Calibration certificates without signature are not valid. Datum Date Leiter des Kalibrierlaboratoriums Head of the calibration laboratory Bearbeiter Person in charge 18.03.2015 Dipl. Ing (FH) J. Kühl Frenco GmbH Verzahnungstechnik DAkkS Kalibrierlaboratorium für Verzahnungsmessgrößen Jakob-Baier-Str. 3 90518 Altdorf Tel. +49(0)9187 9522-0 Fax. +49(0)9187 9522-40 Internet www.frenco.de E-Mail info@frenco.de J. Stellwag

Seite 2 1 profile and helix trace 1.1Calibration method profile and helix trace The gear artefact was calibrated on a gear inspection device whose deviations were determined via a measuring task specific calibration with PTB calibrated artefacts in order to correct the measured values for F ; f H as well as F ß and f Hß (PTB: National Metrology Institute of Germany). 1.2 Measurement conditions The reference axis was determined during the calibration of the gear artefact through the centres of 2 circles. Each of these centres was calculated from a runout measuring whose measuring planes were located on the surface area of 2 cylinders with a diameter of 52.3mm. The distance between the measuring planes for the roundness measurements was 22.5mm (upwards) and 148.5mm (downwards) from the measuring plane. setting plane 1 upwards reference plane VA 12,0 measuring plane VA 22,5 VA 120,0 VB reference plane VB measuring plane VB 15,0 148,5 DAkkS 50,0 setting plane 2 downwards Figure 1: Position of the reference plane and the measuring plan The reference plane of the artefact is the end face of the gear which is located on the opposite side as the official mark. The regression lines were laid through the graphs in accordance with the method of the smallest error square sum.

Seite 3 and helix inspections were carried out at gear VA at flank 1R and 2L. The helix inspections were carried out in the transverse plane on the measuring cylinder d M = 105.000 mm in the right-hand flank position (unfiltered) with a probe ball diameter of 3.0 mm. The evaluation area of the helix trace L ß was situated symmetrically to the centre of the facewidth. During profile inspection the involute areas were touched from root to tip in the measuring planes (see figure 1). Calibration was carried out in the right-hand flank position (unfiltered). The probe ball diameter was 3.0 mm. Used gear data and evaluation areas Number of teeth module m n [mm] pressureangle [ ] Base circle diameter d b [mm] Root rolling length L f [mm] Tip rolling length L a [mm] inspection area L [mm] inspection area L ß [mm] Evaluation area for f hß [mm] 0 30 3.50000 20.0000 98.6677 8.13 27.13 19.00 70.0 60.0 20 r 30 3.28892 18.8817 98.6676 8.13 27.13 19.00 70.0 60.0 20 l 31 3.18283 18.8820 98.6677 8.13 27.13 19.00 70.0 60.0 1.3 Ambient temperatures The room temperature in which the inspections were carried out was between 19.8 C and 19.9 C.

Seite 4 1.4 Measurement results The measurement results are shown in the table below. They are mean values taken from several inspections. Flank number total deviation F ß [ m] angle deviation f Hß [ m] form deviation f fß [ m] 0 1R 1.0 L 0.1 0.9 0 2L 1.2 R 0.6 0.6 20 r 1R 15.2 15.0 0.7 20 r 2L 16.5 16.3 0.9 20 l 1R 1.3 0.9 0.9 20 l 2L 1.0-0.4 1.0 The total helix deviations F ß and the helix angle deviations f Hß, as shown in the table above, have been corrected with the measuring machine deviation as determined in advance. Only helix form deviations f fß can be taken from the uncorrected individual charts (attachment, sheet 1 to 3). Flank number total deviation F [ m] Base circle deviation f H [ m] form deviation f f [ m] 0 1R 1.5-1.0 1.0 0 2L 1.6-0.9 1.2 20 r 1R 1.2-0.8 0.8 20 r 2L 1.2-0.5 1.0 20 l 1R 10.0-10.3 1.0 20 l 2L 10.1-10.1 1.0 The total helix deviations F ß and the helix angle deviations f Hß, as shown in the table above, have been corrected with the measuring machine deviation as determined in advance. Only profile form deviations f f can be taken from the uncorrected individual charts (attachment, sheet 1 to 3).

Seite 5 1.5 The following table shows the expanded measurement uncertainties of the aforementioned measurement results. U of F ß [ m] U of f Hß [ m] U of f fß [ m] 0 1.7 1.3 1.0 20 r 1.9 1.6 1.0 20 l 1.9 1.6 1.0 U of F [ m] U of f H [ m] U of f f [ m] 0 2.0 1.7 1.0 20 r 2.0 1.7 1.0 20 l 2.0 1.7 1.0 The expanded measuring uncertainty as shown above is calculated from the standard measuring uncertainty multiplied by the expansion factor k = 2. It was determined according to DAkkS-DKD-3. The value of the measured variable is within a probability of 95% in the assigned value interval.

Seite 6 2. Pitch and Runout 2.1 Calibration method Pitch and runout of the gear artefact was calibrated on a gear inspection device by using the rosette-procedure. This is an error separation process which is self-traceable. 2.2 Measurement conditions The reference axis was determined like described under section 1.2. The pitch inspection were carried out on the measuring cylinder d M = 106.804 mm with a probe ball diameter of 3.0 mm. The runout deviations were calculated from the space width of the pitch measuring points considering a ball diameter of 7.0 mm. 2.3 Ambient temperatures The room temperature in which the inspections were carried out was between 19.8 C and 20.0 C. 2.4 Measurement results and measurement uncertainty The following table shows the measurement results and the expanded measurement uncertainties. pitch/runout gear VB Left flank Right flank U in µm f p [ m] F p [ m] F r [ m] 0.5 39.4 0.6 2.0 40.0 0.7 43.6 1.0 Attachment 4 shows the graphic. The expanded measuring uncertainty as shown above is calculated from the standard measuring uncertainty multiplied by the expansion factor k = 2. The value of the measured variable is within a probability of 95% in the assigned value interval.

Seite 7 3. DOB (Dimension over balls) 3.1 Calibration method The dimension over measuring circles of artefact B was determined with 2 balls on a length measuring device. The measurement was carried out as a differentiation measurement to a DKD-calibrated setting mandrel. 3.2 Measurement conditions The dimension over measuring circle was determined with 2 balls of diameter 7.000 815mm on an Abbe-type length comparator. It was then converted to a ball diameter of 7.000000 mm, to 20 C and interpolated to a measuring force of 0 N. The measuring plane is shown in figure 1. 3.3 Measurement results Gap 1 consisting of flanks no. DOB Gap 2 consisting of flanks no. DOB mm Measurement uncertainty U [ m] 0 1R and 2L 16R and 17L 116.6342 1.5 20 r 1R and 2L 16R and 17L 116.8785 1.9 20 l 1R and 2L 16R and 17L 116.7391 1.9 The expanded measuring uncertainty as shown above is calculated from the standard measuring uncertainty multiplied by the expansion factor k = 2. The value of the measured variable is within a probability of 95% in the assigned value interval. 3.4 Ambient temperatures The artefact temperature while inspections were carried out was between 20.0 C and 20.1 C. 4. Standards All descriptions and evaluations are as per DIN ISO 21771 (2014), VDI/VDE 2607 (2000) and VDI 2613 (2003), the rule of signs as per VDI/VDE 2612 (2000) and the description of the flanks according to VDI 2613 (2003). 3 Recognition of DAkkS calibration certificates abroad The Deutsche Akkreditierungsstelle GmbH is signatory to the multilateral agreements of the European co-operation for Accreditation (EA) and the International Laboratory Accreditation Cooperation (ILAC) for the mutual recognition of calibration certificates. Further signatories within and outside Europe are found on the websites of EA (www.european-accreditation.org) and ILAC (www.ilac.org).