RT_P18_BLLG_ATTR_UPDT_NOTFN (Transco Billing-Critical Attribute Update Notification Record)

Similar documents
DATASET_GROUP_ADDRS (Address Recurring Dataset)

OPT - O ptional, Mandatory, DOM - D o main i.e. Text, N umeric, D ate, MTimestamp, DEC - Number of decimal places

Allocation of Unidentified Gas Statement 17th October 2011

ENERGY BALANCING INVOICE AI_O_UKL_BALANCING_INVOICE. Contains 24 different record types: -

98 Series Backpressure Regulators and Relief Valves

MT Category 7 Enhancements Overview

SUBJECT TO CHANGE WITHOUT NOTICE

INVOICE DELIVERY BALANCING file

A RWA Performance Comparison for Hybrid Optical Networks combining Circuit and Multi-Wavelength Packet Switching

Financial Review. No member of the Board of Directors has reported accepting any gifts or incentive from any vendor contracted by the association.

Q-Sonic Plus Technology Advances

Test report CVN Project number Page 2 of 2

Comparison of discharge measurements -

Page Max. Possible Points Total 100

Developments in Storage and Monitoring for CCUS

REPORT ON API 21.1 EGM STANDARD Brent E. Berry ABB-Totalflow

(a) Draw the coordinate system you are using and draw the free body diagram of the block during rotation with constant speed.

SMOS NRT BUFR specification

Process Gas Flow Measurement and Performance Evaluation API TECHNICAL REPORT 2571 SECOND EDITION DRAFT, FEBRUARY 2018

THE TRIAL STUDY ABOUT THE MICRO POWER GENERATION BY USE OF VORTEX INDUCED VIBRATION

PROCUREMENT PLAN (Textual Part)

Mass Asset Additions. Overview. Effective mm/dd/yy Page 1 of 47 Rev 1. Copyright Oracle, All rights reserved.

This page intentionally left blank.

5 NUMBER PORTABILITY 5.1 INTRODUCTION

Digitalization in Shipping

The Soniscope a Device for Field Testing of Concrete

VOLUME CALCULATIONS PRACTICE

FINAL DRAFT: October 25, 2010 API TECHNICAL REPORT FUEL GAS MEASUREMENT. FINAL DRAFT: October 25, 2010 Page 0

A FEW E-COMMERCE APPLICATIONS. CIS 400/628 Spring 2005 Introduction to Cryptography. This is based on Chapter 9 of Trappe and Washington

International Journal of Research in Advent Technology Available Online at:

NZQA registered unit standard version 2 Page 1 of 6

m2413c2 the limiting process. 4. Use the alternative form of the derivative to find the derivative of the function at. a. b. c. d. e.

WELL AND BORING REPORT

Two mark questions and answers UNIT I BASIC CONCEPT AND FIRST LAW SVCET

Absolute encoders multiturn

Unified Quiz M4 May 7, 2008 M - PORTION

Case 5 Manual Selection of Water Cooled Condenser and Water Cooler

Sections 01, 02, & 04 (Bressoud and Ehren) 9 October, 2015

Grade: 5 Mathematics Olympiad Qualifier Set: 2

PPA PROCUREMENT PLAN (Textual Part)

PPA PROCUREMENT PLAN (Textual Part)

APPLICATION NOTE: Accuracy standards. The physics of accuracy

Stainless Steel Sanitary Products. 3A & BPE Industry Standard Designs Without Brand Name Price. More For Less

Math Round. Any figure shown may not be drawn to scale.

INVOICE EXPLAINER GAS

Technical Data Sheet DPT & DPIT-4005 SERIES DIFFERENTIAL PRESSURE TRANSDUCERS. Features. Description

PROJECT TITLE: 4.50 MW AKKIHEBBAL MINI HYDEL SCHEME, CAUVERY HYDRO ENERGY LTD., INDIA

Physics I Exam 1 Spring 2015 (version A)

PPA PROCUREMENT PLAN (Textual Part)

Government Furnished Property Process Implementation Training

Distribution Date: 27-Aug-07

Turbines and turbine sets Measurement of emitted airborne noise Engineering/survey method

VISY-Quick Communication Protocol

CECOER. Renewable Energy Control Center. How technologies have boosted remote operations. Agder Energi-konferansen

Review questions for Math 111 final. Please SHOW your WORK to receive full credit Final Test is based on 150 points

Given Find Water Properties

PROCURE-TO-PAY. WAWF Government Furnished Property (GFP) Module: End to End. Presented by: Carol Vigna, DPAP & Pamela Rooney, Support to DPAP

SSi Super Systems Inc.

Applied Calculus I Practice Final Exam

WYANDOTTE MUNICIPAL SERVICES COMMUNITY WIND ENERGY PROJECT WIND RESOUCE SUMMARY

A Correlation of. Student Activity Book. to the Common Core State Standards for Mathematics. Grade 2

ALBERTA CAPITAL FINANCE AUTHORITY LOAN TYPES

OU_ACTIVITY Journal Entry Reference Guide

ACCEPTANCE PROCEDURE FOR ROMET ROTARY METER BODIES AND/OR MECHANICAL NON-CONVERTING AND CONVERTING MODULES

Operating instructions Compressed air meter SD / / 2013

DUVAL COUNTY PUBLIC SCHOOLS PAYMENT CALENDAR

Designer policy for carbon and biodiversity co-benefits under global change

UA-SS FAQS UA-SS FAQS

Section 1.4 Composition of Functions

Weather Data Weather Forecasts Weather Risk Consultancy Weather Risk Management Software SWS Weather Data Format

Metric Conversion: Stair-Step Method

Accuracy Calibration Certificate

The World Bank Transport Connectivity and Asset Management Project (P132833)

Flow Measurement in Pipes and Ducts COURSE CONTENT

End of Services Support Notice

FAST CHECK THICKNESS GAGE

Foundations of Earth Science, 6e Lutgens, Tarbuck, & Tasa

Regents Exam Questions A2.S.7: Exponential Regression

SIMATIC Ident Industrial Identification Systems

14 ULTRATOMIC WALL CLOCK

AAPT UNITED STATES PHYSICS TEAM AIP 2016

R800-1M Statement of Activity Custom Transactions Source: ABC COMPANY 01/31/2014 4:40:59 AM

Implementation Status & Results Burundi Burundi - Emergency Energy Project from IDA CRW (P122217)

Ph.D. QUALIFYING EXAMINATION DEPARTMENT OF PHYSICS AND ASTRONOMY WAYNE STATE UNIVERSITY PART I. WEDNESDAY, January 3, :00 12:00

( ). Switch x and y and solve for y:

Chapter 6 Polynomial Models and Linear Systems Section 6.1 Solving Polynomial Equations

Determine whether y varies directly with x. If so, find the constant of variation k and write the equation.

Page 1 =============================== = DEEP SEA DRILLING PROJECT = = VANE SHEAR DATA BASE = =============================== I.

Big Data Paradigm for Risk- Based Predictive Asset and Outage Management

DIGITAL ALTIMETER ALL-in-ONE

Victoria Advance Exploration Project Past, Present and What s Next

Particle Motion Problems

UNC Demand Estimation Sub-committee Minutes Wednesday 07 November 2012

FA A D

EA-10/14. EA Guidelines on the Calibration of Static Torque Measuring Devices. Publication Reference PURPOSE

GHANA MINISTRY OF ROADS AND HIGHWAYS URBAN TRANSPORT PROJECT 4334-GH P DEPARTMENT OF URBAN ROADS. Serial No. Component Description*

Flow Management Devices, LLC An ISO 9000:2008 Certified Company

Class 4 Conversion of Units

BR-01 PAINT BRIDGE NO. 55 C GENERAL PLAN 720'-0" VC 605'-0" VC 1. FOR INDEX TO PLANS, QUANTITIES, AND GENERAL NOTES, SEE "INDEX TO PLANS" SHEET.

Earthquake,Tsunami,Volcano Monitoring & Warning System in Korea. Jimin Lee Earthquake & Volcano Monitoring Division KMA

Transcription:

RT_P18_BLLG_ATTR_UPDT_NOTFN (Transco Billing-Critical Attribute Update Notification Record) RECORD/FIELD NAME OPT DOM LNG DEC DESCRIPTION *OCCURS MAX 175,000 * TRANSACTION_TYPE M T 3 0 DEFINITION: A code identifying the type of Transaction that this record represents. VALUE: P18 METER_POINT_REFERENCE M N 10 0 DEFINITION: A system generated unique identifier for the point at which a meter is, has been or will be connected to the gas network. CONTEXT: The reference of the Meter Point whose Billing Critical attributes have been updated. UPD_RECEIPT_DATE M D 8 0 DEFINITION: Date on which the Asset Update notification was received by GT. FORMAT: YYYYMMDD ASSET_OWNERSHIP_EFFECTIVE_DATE M D 8 0 DEFINITION: Date from which the Shipper was responsible for the superseded (i.e. previous) Asset. This will be populated with either, - The installation date of the Asset OR - The Shipper s Confirmation Effective Date (where the asset was installed prior to this date). FORMAT: YYYYMMDD ASSET_OWNERSHIP_END_DATE M D 8 0 DEFINITION: Date on which the Shipper ceased to be responsible for the Asset. This will be populated with either, - The date on which the superseded asset was removed OR - The Shipper s Confirmation End Date (where the asset was removed after this date). FORMAT: YYYYMMDD PREVIOUS_METER_PRODUCT_ID O T 10 0 DEFINITION: An MDD defined value to identify a set of Meters with common/identical attributes. CONTEXT: Product Id of the Meter Model held by GT, prior to the Asset PREVIOUS_METER_MODEL_NAME O T 10 0 DEFINITION: A Code, which uniquely identifies the Meter Model. CONTEXT: Model Name of the Meter Model held by GT, prior to the Asset 2006, xoserve Ltd Page 1 of 9 Version 2 Draft

PREVIOUS_METER_MANUFACTURER O T 3 0 DEFINITION: The unique code of _CODE the Manufacturer of the Meter. CONTEXT: Manufacturer Code of the Meter Model held by GT, prior to the Asset PREVIOUS_METER_MANUFACTURED O N 4 0 DEFINITION: Year of Manufacture _YEAR for the Meter as stamped on the Meter, expressed as a century date (e.g. 1981). CONTEXT: Year of Meter Manufacture held by GT, prior to the Asset PREVIOUS_METER_SERIAL_NUM O T 14 0 DEFINITION: The manufacturer's Serial Number including alphanumeric characters. CONTEXT: Meter Serial Number held by GT, prior to the Asset PREVIOUS_METER_STATUS O T 2 0 DEFINITION: Industry standard code representing the Status of the Meter. CONTEXT: For cases where a Meter Exchange has occurred, this would always be RE since the previous Meter has been removed and its status prior to the removal is not recorded. VALUE: RE - Removed PREVIOUS_METER_TYPE O T 5 0 DEFINITION: Code to determine the Type of the Meter. CONTEXT: Meter Type of the Meter Model held by GT, prior to the Asset VALUES: D - Diaphragm of Unknown Material, R - Rotary, L - Leather Diaphragm, S - Synthetic, T - Turbine, U - Ultrasonic, Z - Unknown PREVIOUS_METER_MECHANISM O T 5 0 DEFINITION: A coded value describing the payment Mechanism of the Meter. CONTEXT: Meter Mechanism Code held by GT, prior to the Asset VALUES: CM - Coin Meter, ET - Electronic Token Meter, CR - Credit, MT - Mechanical Token Meter, PP - Prepayment, TH - Thrift, U - Unknown PREVIOUS_METER_CAPACITY O N 10 4 DEFINITION: The maximum volume of gas (Q max) that can be passed through the asset per hour, based upon the manufacturer's maximum value. CONTEXT: Measuring Capacity of the Meter Model held by GT, prior to the Asset 2006, xoserve Ltd Page 2 of 9 Version 2 Draft

PREVIOUS_METER_NUM_DIAL_ O N 2 0 DEFINITION: Number of OR_DIG Meter, which are to be considered during the Meter reading. CONTEXT: Meter Model Number of Dials or Digits held by GT, prior to the Asset PREVIOUS_METER_UNITS_ O T 5 0 DEFINITION: Code indicating the OF_MEASURE units of the meter model, prior to the Asset CONTEXT: Meter Model Units of Measure held by GT, prior to the Asset VALUES: SCFH - Standard Cubic Feet per Hour, SCMH - Standard Cubic Meters per Hour PREVIOUS_METER_READING _FACTOR O N 6 3 DEFINITION: Multiplication Factor to apply to the resultant index advance indicated by the Meter Reading. CONTEXT: Reading Factor of the Meter Model held by GT, prior to the Asset PREVIOUS_MPO_METER _CORRN_FCTR O N 9 6 DEFINITION: A fixed factor applied where no Converter is fitted and the meter reading needs to be corrected for pressure, altitude and/or temperature. CONTEXT: Meter Correction Factor of the Meter Point held by GT, prior to the Asset PREVIOUS_CONVERTER _PRODUCT_ID O T 10 0 DEFINITION: An MDD defined value to identify a set of Converters with common/identical attributes. CONTEXT: Product Id of the Converter Model held by GT, prior to the Asset PREVIOUS_CONVERTER_MODEL O T 10 0 DEFINITION: A Code, which _NAME uniquely identifies the Converter Model. CONTEXT: Model Name of the Converter Model held by GT, prior to the Asset PRVS_CONVERTER_MANUFACTURER _CODE O T 3 0 DEFINITION: The unique code of the Manufacturer of the Converter. CONTEXT: Manufacturer Code of the Converter Model held by GT, prior to the Asset PRVS_CONVERTER_MANUFACTURED _YEAR O N 4 0 DEFINITION: Year of Manufacture for the Converter as stamped on the 2006, xoserve Ltd Page 3 of 9 Version 2 Draft

Converter, expressed as a century CONTEXT: Year of Converter Manufacture held by GT, prior to the Asset PREVIOUS_CONVERTER_SERIAL _NUM O T 14 0 DEFINITION: The manufacturer's Serial Number including alphanumeric characters. CONTEXT: Converter Serial Number held by GT, prior to the Asset PREVIOUS_CONVERTER _STATUS O T 2 0 DEFINITION: Industry standard code representing the Status of the Converter. CONTEXT: For cases where a Converter Exchange has occurred, this would always be RE since the previous Converter has been removed and its status prior to the removal is not recorded. VALUE: RE - Removed PRVS_CONVERTER_CORRECTING _BASIS O T 5 0 DEFINITION: The Conversion Basis the Converter is set up to convert against. CONTEXT: Conversion Basis Code of the Converter Model held by GT, prior to the Asset VALUES: C - Compressibility CP - Compressibility & Pressure CT - Compressibility & Temperature CPT - Compressibility, Pressure & Temperature P - Pressure PT - Pressure & Temperature D - Density CPD - Compressibility, Pressure and Density CTD - Compressibility, Temperature and Density CPTD - Compressibility, Pressure, Temperature and Density PD - Pressure and Density T - Temperature TPD - Temperature, Pressure, Density TD - Temperature and Density PREVIOUS_CONVERTER_ CORRN_FACTOR O N 9 6 DEFINITION: A fixed factor applied where the Converter does not convert for all inputs, so readings still require correction to account for variations due to 2006, xoserve Ltd Page 4 of 9 Version 2 Draft

pressure, altitude and/or temperature. CONTEXT: Converter Conversion Factor held by GT, prior to the Asset PRVS_CONVERTER_NUM_DIAL _UNCORRD O N 2 0 DEFINITION: Uncorrected Number of Converter, which are to be considered during the Asset reading. CONTEXT: Uncorrected Number of Dials or Digits of the Converter Model held by GT, prior to the Asset PRVS_CONVERTER_RDNG_ O N 6 3 DEFINITION: FCTR_UNCORRD Multiplication Factor to apply to the resultant index advance indicated by the Uncorrected Converter Reading. CONTEXT: Uncorrected Reading Factor of the Converter Model held by GT, prior to the Asset PRVS_CONVERTER_NUM_DIAL_ CORRD O N 2 0 DEFINITION: Corrected Number of Converter, which are to be considered during the Asset reading. CONTEXT: Corrected Number of Dials or Digits of the Converter Model held by GT, prior to the Asset PRVS_CONVERTER_RDNG_FCTR _CORRD O N 6 3 DEFINITION: Multiplication Factor to apply to the resultant index advance indicated by the Corrected Converter Reading. CONTEXT: Corrected Reading Factor of the Converter Model held by GT, prior to the Asset CURRENT_METER_PRODUCT_ID O T 10 0 DEFINITION: An MDD defined value to identify a set of Meters with common/identical attributes. CONTEXT: Product Id of the Meter Model held by GT, after the Asset CURRENT_METER_MODEL_NAME M T 10 0 DEFINITION: A Code, which uniquely identifies the Meter Model. CONTEXT: Model Name of the Meter Model held by GT, after the Asset CURRENT_METER_MANUFACTURER O T 3 0 DEFINITION: The unique code of _CODE the Manufacturer of the Meter. CONTEXT: Manufacturer Code of 2006, xoserve Ltd Page 5 of 9 Version 2 Draft

the Meter Model held by GT, after the Asset CURRENT_METER_MANUFACTURED _YEAR M N 4 0 DEFINITION: Year of Manufacture for the Meter as stamped on the Meter, expressed as a century date (e.g. 1981). CONTEXT: Year of Meter Manufacture held by GT, after the Asset CURRENT_METER_SERIAL_NUM M T 14 0 DEFINITION: The manufacturer's Serial Number including alphanumeric characters. CONTEXT: Meter Serial Number held by GT, after the Asset CURRENT_METER_STATUS O T 2 0 DEFINITION: Industry standard code representing the Status of the Meter. CONTEXT: Meter Status held by GT, after the Asset VALUES: CA - Capped, CL - Clamped, DM - Damaged, FA - Faulty, LI - Live CURRENT_METER_TYPE O T 5 0 DEFINITION: Code to determine the Type of the Meter. CONTEXT: Meter Type of the Meter Model held by GT, after the Asset VALUES: D - Diaphragm of Unknown Material, R - Rotary, L - Leather Diaphragm, S - Synthetic, T - Turbine, U - Ultrasonic, Z - Unknown CURRENT_METER_MECHANISM M T 5 0 DEFINITION: A coded value describing the payment Mechanism of the Meter. CONTEXT: Meter Mechanism Code held by GT, after the Asset VALUES: CM - Coin Meter, ET - Electronic Token Meter, CR - Credit, MT - Mechanical Token Meter, PP - Prepayment, TH - Thrift, U - Unknown CURRENT_METER_CAPACITY O N 10 4 DEFINITION: The maximum volume of gas (Q max) that can be passed through the asset per hour, based upon the manufacturer's maximum value. CONTEXT: Measuring Capacity of the Meter Model held by GT, after the Asset CURRENT_METER_NUM_DIAL_OR_DIG M N 2 0 DEFINITION: Number of Meter, which are to be considered 2006, xoserve Ltd Page 6 of 9 Version 2 Draft

during the Meter reading. CONTEXT: Meter Model Number of Dials or Digits held by GT, after the Asset CURRENT_METER_UNITS_OF _MEASURE M T 5 0 DEFINITION: Code indicating the units of the meter model held by GT, after the Asset CONTEXT: Meter Model Units of Measure held by GT, after the Asset VALUES: SCFH - Standard Cubic Feet per Hour, SCMH - Standard Cubic Meters per Hour CURRENT_METER_READING _FACTOR M N 6 3 DEFINITION: Multiplication Factor to apply to the resultant index advance indicated by the Meter Reading. CONTEXT: Reading Factor of the Meter Model held by GT, after the Asset CURRENT_MPO_METER_CORRN _FCTR O N 9 6 DEFINITION: A fixed factor applied where no Converter is fitted and the meter reading needs to be corrected for pressure, altitude and/or temperature. CONTEXT: Meter Correction Factor of the Meter Point held by GT, after the Asset CURRENT_CONVERTER_PRODUCT _ID O T 10 0 DEFINITION: An MDD defined value to identify a set of Converters with common/ identical attributes. CONTEXT: Product Id of the Converter Model held by GT, after the Asset CURRENT_CONVERTER_MODEL _NAME O T 10 0 DEFINITION: A Code, which uniquely identifies the Converter Model. CONTEXT: Model Name of the Converter Model held by GT, after the Asset CURR_CONVERTER_MANUFACTURER _CODE O T 3 0 DEFINITION: The unique code of the Manufacturer of the Converter. CONTEXT: Manufacturer Code of the Converter Model held by GT, after the Asset CURR_CONVERTER_MANUFACTURED _YEAR O N 4 0 DEFINITION: Year of Manufacture for the Converter as stamped on the Converter, expressed as a century date (e.g. 1981). 2006, xoserve Ltd Page 7 of 9 Version 2 Draft

CONTEXT: Year of Converter Manufacture held by GT, after the Asset CURRENT_CONVERTER_SERIAL _NUM O T 14 0 DEFINITION: The manufacturer's Serial Number including alphanumeric characters. CONTEXT: Converter Serial Number held by GT, after the Asset CURRENT_CONVERTER_STATUS O T 2 0 DEFINITION: Industry standard code representing the Status of the Converter. CONTEXT: Converter Status held by GT, after the Asset VALUES: DM - Damaged, FA Faulty, LI - Live CURR_CONVERTER_CORRECTING _BASIS O T 5 0 DEFINITION: The Conversion Basis the Converter is set up to convert against. CONTEXT: Conversion Basis Code of the Converter Model held by GT, after the Asset VALUES: C Compressibility CP - Compressibility & Pressure CT - Compressibility & Temperature CPT - Compressibility, Pressure & Temperature P Pressure PT - Pressure & Temperature D Density CPD - Compressibility, Pressure and Density CTD - Compressibility, Temperature and Density CPTD - Compressibility, Pressure, Temperature and Density PD - Pressure and Density T Temperature TPD - Temperature, Pressure, Density TD - Temperature and Density CURRENT_CONVERTER_CORRN _FACTOR O N 9 6 DEFINITION: A fixed factor applied where the Converter does not convert for all inputs, so readings still require correction to account for variations due to pressure, altitude and/or temperature. CONTEXT: Converter Conversion Factor held by GT, after the Asset CURR_CONVERTER_NUM_DIAL_ UNCORRD O N 2 0 DEFINITION: Uncorrected Number of Converter, which are to be considered during the Asset reading. 2006, xoserve Ltd Page 8 of 9 Version 2 Draft

CONTEXT: Uncorrected Number of Dials or Digits of the Converter Model held by GT, after the Asset CURR_CONVERTER_RDNG_FCTR_ UNCORRD O N 6 3 DEFINITION: Multiplication Factor to apply to the resultant index advance indicated by the Uncorrected Converter Reading. CONTEXT: Uncorrected Reading Factor of the Converter Model held by GT, after the Asset CURRENT_CONVERTER_NUM_DIAL_ CORRD O N 2 0 DEFINITION: Corrected Number of Converter, which are to be considered during the Asset reading. CONTEXT: Corrected Number of Dials or Digits of the Converter Model held by GT, after the Asset CURR_CONVERTER_RDNG_FCTR_ CORRD O N 6 3 DEFINITION: Multiplication Factor to apply to the resultant index advance indicated by the Corrected Converter Reading. CONTEXT: Corrected Reading Factor of the Converter Model held by GT, after the Asset -------- * 353 2006, xoserve Ltd Page 9 of 9 Version 2 Draft