MALVERN OMNISEC RESOLVE, REVEAL, REALIZE MOLECULAR WEIGHT MOLECULAR SIZE MOLECULAR STRUCTURE

Similar documents
MALVERN OMNISEC RESOLVE, REVEAL, REALIZE MOLECULAR WEIGHT MOLECULAR SIZE MOLECULAR STRUCTURE

MALVERN ADVANCED GPC/SEC DETECTORS SETTING THE STANDARD MOLECULAR WEIGHT MOLECULAR SIZE MOLECULAR STRUCTURE

Differentiation of polymer branching and composition using the Mark Houwink plot

Optimization of PLA/PLGA molecular weight and structure to suit final application requirements

Setting the Standard for Advanced GPC/SEC Systems

GPC/SEC Analysis of Polymer Degradation

The power of multi-detector SEC in the analysis of antibodies

How to use GPC/SEC for compositional analysis

How switching mobile phases can improve your OMNISEC results

MASTERSIZER 3000 SMARTER PARTICLE SIZING

GPC/SEC Analysis of Polymer Solutions Used in Inkjet Printing

Benefit of light scattering technologies (RALS/LALS/MALS) and multidetection characterization in life science research?

10 REASONS THAT THE ZETASIZER NANO IS CHOSEN FOR SCIENTIFIC SUCCESS

Setting the Standard for GPC. Complete Guide for GPC / SEC / GFC Instrumentation and Detection Technologies. The Right Instrument for Your Application

The ultimate in desktop particle characterization

Latest Developments in GPC Analysis of Adhesive and Sealant Polymers Mark Pothecary PhD Americas Product Manager Malvern Instruments

ZS90. The ultimate in desktop particle characterization. Particle size. Zeta potential. Molecular weight

MASTERSIZER 3000 SMARTER PARTICLE SIZING

The ultimate in desktop particle characterization

MASTERSIZER 3000 SMARTER PARTICLE SIZING

Introduction to the calculators in the Zetasizer software

An Introductions to Advanced GPC Solutions

Malvern Macromolecular Solutions. Innovative Solutions in Material Characterization

Tips & Tricks GPC/SEC: From a Chromatogram to the Molar Mass Distribution

MEASURING PROTEIN AGGREGATION WITH THE VISCOTEK SEC-MALS 20

Using High Speed/High Resolution Size Exclusion Chromatography Separation of Polymeric Materials with Light Scattering Detection

EcoSEC - semi-micro GPC/SEC system for high throughput polymer analysis

GPC/SEC Practical Tips and Tricks. Thomas Dent Applications Scientist Agilent Technologies. October, 2011 Gulf Coast Conference

ION CHROMATOGRAPHY SYSTEM S 150

Quick guide to selecting columns and standards for Gel Permeation Chromatography and Size Exclusion Chromatography SELECTION GUIDE

Characterization of polyphenylene sulphide using the Agilent PL-GPC 220 High Temperature GPC System with triple detection

KINEXUS DSR SERIES REDEFINING RHEOMETER CAPABILITIES FOR ASPHALT TESTING

Investigating the Relationship Between the Rheological Properties of Hyaluronic Acid and its Molecular Weight and Structure using Multidetector

next generation Welcome to the Dispersion options Smarter particle sizing Your sample, expertly processed and prepared Particle size

Understanding the colloidal stability of protein therapeutics using dynamic light scattering

Component specific particle characterisation of the active components in a pharmaceutical topical formulations

Agilent 385-ELSD Evaporative Light Scattering Detector

DEVELOPING A BIOFORMULATION STABILITY PROFILE

Analysis of Star Polymers Using the Agilent 1260 Infinity Multi-Detector GPC/SEC System

How Molecular Weight and Branching of Polymers Influences Laser Sintering Techniques

Determining cure profile and post-cure shrinkage of photopolymers using UV accessory on a rotational rheometer

Tips & Tricks GPC/SEC: Inter-Detector Delay

GPC/SEC An essential tool for polymer analysis

Discriminating between polymorphs of acetaminophen using Morphologically-Directed Raman Spectroscopy (MDRS)

Progress toward reliable NC molecular mass distribution by GPC

Polymer analysis by GPC-SEC. Technical Note. Introduction

Macromolecular Chemistry

The Diffusion Barrier Technique, Practical Aspects and Data interpretation

Use of DLS/Raman to study the thermal unfolding process of lysozyme

Comprehensive Polymer Analysis Strategies

Bruker Daltonics. EASY-nLC. Tailored HPLC for nano-lc-ms Proteomics. Nano-HPLC. think forward

Overcoming and quantifying Wall Slip in measurements made on a rotational rheometer

Malvern - Innovative Solutions in Material Characterization

Agilent 385-ELSD Evaporative Light Scattering Detector

MODERN HPLC FOR PRACTICING SCIENTISTS

Studying the Effect of Steric Layer Thickness on Emulsion Stability

Nanoparticle Analyzer

FLASH CHROMATOGRAPHY

KINEXUS SERIES REDEFINING RHEOMETER CAPABILITIES

Determination of Polymer Modifier in Asphalt

Advanced GPC. GPC On Tour, Barcelona, 28 th February The use of Advanced Detectors in GPC

Chemistry Instrumental Analysis Lecture 31. Chem 4631

Optimizing GPC Separations

Gel Permeation Chromatography

SurPASS. Electrokinetic Analyzer for Solid Samples. ::: Innovation in Materials Science

KINEXUS SERIES REDEFINING RHEOMETER CAPABILITIES

Litesizer Sheet 1. [Home]

Measurements of protein electrophoretic mobility using the Zetasizer Nano ZSP

Biochemistry. Biochemical Techniques HPLC

GPC/SEC standards. Product guide

Bohlin. Rheological instruments backed with rheological experience. Rheological properties

Varian Galaxie Chromatography Data System for Preparative HPLC

GPC/SEC standards. Product guide

Material Relationships - distributor details

High Performance Liquid Chromatography

Practical Steps in GPC Method Development

MICROCAL ITC SYSTEMS UNDERSTANDING BIOMOLECULAR INTERACTIONS LABEL-FREE BINDING ANALYSIS MICROCALORIMETRY

ZETASIZER NANO Series PERFORMANCE, SIMPLICITY, VERSATILITY

Rapid Screening and Analysis of Components in Nonalcoholic Drinks Application

Particle Characterization Laboratories, Inc.

Particle Analysis at the Touch of a Button. Litesizer series

Perseverance. Experimentation. Knowledge.

Comparison of Polymer Separation by Size Exclusion Chromatography and Asymmetric Flow Field Flow Fractionation

Advantages of Agilent AdvanceBio SEC Columns for Biopharmaceutical Analysis

Precision and accuracy of protein size determination using the ActiPix TDA200 Nano-Sizing System

Application Note. Gas Chromatography/Mass Spectrometry/Food Safety. Abstract. Authors

Characterization of protein aggregates in suspension and on a filter membrane by Morphologically-Directed Raman Spectroscopy

The Low-Temperature Evaporative Light-Scattering Detector (LT-ELSD)

RH7-D & RH10-D CAPILLARY RHEOMETERS

Method Transfer between HPLC and UHPLC Instruments Equipment-related challenges and solutions

Chapter content. Reference

GPC / SEC Theory and Understanding

Nanobubble Applications and Characterization by Nanoparticle Tracking Analysis

Agilent 1260 Infinity Evaporative Light Scattering Detector (ELSD)

DVS Intrinsic Compact and Economical Dynamic Vapor Sorption System

The Importance of Area and Retention Time Precision in Gas Chromatography Technical Note

Systems, services and solutions for material characterization

Separation of Explosives in EPA 8330: Column Choices Optimize Speed, Resolution, and Solvent Use. Application. Authors. Abstract.

Speeding up 2D chromatography (HPLCxSEC) at it s limits. ..fast, faster ups broken...

Maximizing Performance Through GPC Column Selection

Transcription:

MOLECULAR WEIGHT MOLECULAR SIZE MOLECULAR STRUCTURE MALVERN OMNISEC RESOLVE, REVEAL, REALIZE

Resolve, reveal, realize OMNISEC - A NEW STANDARD IN GPC/SEC Malvern s OMNISEC is a complete gel permeation/size exclusion chromatography (GPC)/(SEC) solution consisting of systems, detectors and software. Malvern s expertise has enabled the development of the most sensitive and accurate multi-detector GPC/SEC system for the characterization of synthetic and natural polymers, and proteins. OMNISEC can accurately measure the most important characterization parameters including: Absolute molecular weight and molecular weight distribution Intrinsic viscosity and molecular structure Sample concentration And many more 2 www.malvern.com

OMNISEC - AT A GLANCE The complete, integrated OMNISEC solution is made up of 3 components: OMNISEC RESOLVE - an integrated pump, degasser, autosampler and column oven for managing the separation in a single advanced unit. OMNISEC REVEAL - an integrated multidetector module for the characterization of synthetic and natural polymers, and proteins: The most sensitive light scattering detector in the world Unrivalled baseline stability on all detectors for greater sensitivity to low concentrations of sample Self balancing viscometer detector Wide UV/VIS wavelength range to cover all applications Simple and intuitive to use, due to advanced design features OMNISEC software - completely new version 10 to make GPC/SEC analysis as easy and intuitive as possible. Supports the power of advanced detection, reduces workload and improves your productivity. OMNISEC is easier to use Autosampler temperature control (4-60 C) protects proteins from degradation and improves polymer dissolution Waste-free injections from vials or 96-well microtiter plates The low volume degasser enables faster mobile phase exchange Inert (316 stainless steel) viscometer pressure transducers can tolerate a wider ph range System temperature control (up to 65 C) reduces operating backpressure Greater efficiency through work-flow based software for system control and analysis The revolutionary user exchangeable viscometer capillary module reduces service time and cost Integrated pump back seal washing reduces seal wear. OMNISEC gives better results The new light scattering detector is the most sensitive on the market, enabling measurements of molecular weights as low as 200 Da, injection masses as low as 100 ng of material and samples with low dn/dc Integrated detectors module minimizes inter-detector band broadening Column and detector temperature control (20-65 C) improves resolution and stabilizes baselines Flexible autosampler delivers accurate and precise volumes for unsurpassed data reproducibility. 3

Resolve, reveal, realize OMNISEC RESOLVE AND OMNISEC REVEAL The complete GPC/SEC solution OMNISEC RESOLVE has been designed using our 30 years of experience in GPC/ SEC and precision electronics to achieve the highest possible standard in chromatographic performance. The efficient degasser, lowpulsation pump, outstanding autosampler and large capacity column oven combine to give reduced baseline noise and improved stability to maximize measurement sensitivity and accuracy. OMNISEC REVEAL is the integrated multi-detector platform. It is available with refractive index, full range UV/Vis photodiode array, light scattering and viscosity detectors to meet the needs of a wide range of applications. Each detector is outstandingly sensitive and stable to ensure it delivers first class GPC/SEC data for every sample. WITH OMNISEC YOU CAN WITH... OMNISEC REVEAL Measure the concentration of almost any solute Measure the concentration of chromophore-containing samples Measure absolute molecular weight and molecular weight distribution of synthetic and natural polymers, and proteins Measure the intrinsic viscosity (IV) of your sample to investigate molecular structure and branching Combine the results to measure other properties such as hydrodynamic radius (Rh), radius of gyration (Rg), and Mark-Houwink parameters Achieve better baseline stability for improved accuracy and sensitivity Refractive Index (RI) UV/Vis Absorbance (PDA) Light Scattering (LS) Viscometer Triple Detection (TD) Temperature controlled detectors OMNISEC RESOLVE Improve baseline stability Reduce downtime with faster solvent changeover and equilibration Protect fragile samples such as proteins from degradation Reduce viscosity of high viscous solvents such as DMSO Minimize waste of precious samples Improve separation quality and resolution Low pulsation pump Low volume degasser Temperature controlled autosampler (4-60 C) Waste free autosampler Integrated column oven 4 www.malvern.com

INTRODUCTION TO TECHNIQUE AND TECHNOLOGY Absolute Molecular Weight, Molecular Size The highest quality GPC/SEC measurement requires two things: a good separation of the sample - RESOLVE sensitive detectors to characterize the separated sample - REVEAL GPC/SEC Separation As the dissolved sample flows through the porous column matrix, the individual molecules diffuse in and out of the pores. Larger molecules are excluded from more pores, and so travel through the column faster, eluting earlier while the smaller molecules elute later. The result is a separation by hydrodynamic size for measurement by the detectors. Detection Once separated, the sample can be characterized using one or more detectors to reveal its nature. Multi-detector GPC/ SEC uses a combination of detectors to fully characterize the sample in a single experiment. Refractive index and absorbance (UV/ Vis) detectors measure a sample s concentration Light scattering detectors measure absolute molecular weight A Viscometer measures intrinsic viscosity, which is representative of a molecular structure, density and branching Performance delivered OMNISEC delivers both the separation and detection performance required to generate the most sensitive and accurate results. When a NIST standard is measured using OMNISEC, the standard deviation of 10 repeat injections of a solution containing only 5 μg of the sample is just 1%. OMNISEC will provide the data quality for your application. 5

Resolve, reveal, realize SYNTHETIC AND NATURAL POLYMERS Absolute Molecular Weight, Molecular Size, Structure Product performance For both synthetic polymers and natural polymers, product performance is key to your success. For example: If a polymer molecular weight changes from the specification, it may be too weak or too difficult to process Poor control of PLA/PLGA molecular weight could result in uncontrolled drug release A change in branching level in polycarbonates will affect the final product brittleness Ineffectual derivatization or cross-linking of HA products may result in poor product performance and more rapid clearance from the body If the molecular weight of a cellulose derivative in eye-drops is too low it will be cleared too quickly from the eye Take control of polymer performance GPC is used in many industries as a development and QC tool. With a full understanding of your polymer s characteristics: The polymer manufacturer can appropriately grade and sell their product The polymer scientist can fully investigate the structure/molecular weight relationships A drug delivery scientist can optimize controlled release Hyaluronic acid can be marked for use in the appropriate surgical or cosmeceutical application The eye-drop manufacturer can better control clearance rates PROTEINS Absolute Molecular Weight, Aggregation, Conjugation Molecular weight is important for proteins because it relates directly to their quaternary structure, oligomeric state and activity. Protein aggregation in a biopharmaceutical reduces efficacy and risks an immunogenic reaction. With OMNISEC you can determine aggregate, molecular weight, size and structure. Conjugation affects clearance rates and efficacy. With OMNISEC you can measure the extent of conjugation, for example, of PEGylated proteins. Intrinsic viscosity relates to protein structure allowing you to distinguish between globular and fibrous aggregates. In addition, it can be used to calculate hydrodynamic size (Rh). 6 www.malvern.com

OMNISEC RESOLVE Integrated separations module OMNISEC RESOLVE is a combined pump, degasser, autosampler and column oven for mobile phase delivery and sample injection. What benefits does a complete GPC/SEC system that includes OMNISEC RESOLVE provide? A complete solution from a single manufacturer with an intuitive software package that handles everything from instrument control to data acquisition and data analysis Unattended operation using the autosampler, even with sensitive samples such as proteins, thanks to its temperature control FEATURES OF OMNISEC RESOLVE Degasser Solvent Degasser Low volume degasser makes for rapid solvent and buffer changeover Improved degassing efficiency means more stable detector baselines Isocratic pump Pump Self-priming and optimized for GPC/SEC to offer excellent flow rate stability to reduce baseline noise in all detectors Integrated backflushing automatically protects seals from mobile phase salt precipitation Column oven Injection loop Maintain a stable separation temperature from 20 to 65 C Accommodate up to 6 analytical columns or 1 GE Tricorn TM column Columns and oven Autosampler Autosampler Inject samples from vials or 96-well microtiter plates with unrivalled accuracy and precision Cool sensitive samples like proteins to 4 C to protect them from aggregation Warm viscous samples like those in DMSO to 60 C to improve injection volume accuracy Zero injection volume overhead mode prevents wastage of your most precious samples 7

Resolve, reveal, realize OMNISEC REVEAL Integrated multi detector module OMNISEC REVEAL is an integrated multi-detector module for advance GPC/ SEC measurements incorporating refractive index, UV/Vis absorbance, light scattering and intrinsic viscosity detectors. The high sensitivity and measurement quality that it provides ensures maximum return on your investment. It can act as a stand alone detector connected to your existing GPC/SEC system or as a complete GPC/SEC solution in combination with the OMNISEC RESOLVE module. An integrated design keeps all of the detectors in one compartment, affording multiple advantages: Inter-detector tubing is minimized reducing band broadening to improve data quality and result accuracy The detectors and the inter-detector tubing are all maintained at the same temperature to further improve data quality by maintaining baseline stability Refractive index Intrinsic viscosity + - - + OMNISEC REVEAL s refractive index detector measures the concentration of almost any solute. Its robust flow cell allows it to be kept series with the other detectors, maximizing sensitivity and minimizing band broadening. Light scattering The new pressure transducers in OMNISEC REVEAL s differential viscometer improve baseline stability, sensitivity and robustness. Their 316 stainless steel construction means few limitations with salts or ph. It has an interchangeable capillary module for fast user replacement and the ability to self-balance for simple, automatic setup. UV/Vis RALS Detector Lens Lens LALS Detector Laser Mobile phase Mobile phase The unique light scattering detector combines the sensitivity of 90 Right Angle Light Scattering (RALS) with the accuracy of 7 Low-Angle Light Scattering (LALS). Its superior sensitivity makes it the ideal choice for measuring precious samples where only small injections can be afforded or for samples with low dn/dc, while its 18 μl flow cell minimizes band broadening. The UV/Vis photodiode array (PDA) covers wavelengths of 190-900 nm, opening up absorbance measurements to a wider application range. 8 www.malvern.com

DEDICATED INTUITIVE SOFTWARE Designed with the GPC/SEC workflow in mind Workflow oriented software OMNISEC software v10 has been designed with you and your priorities in mind. It makes GPC/SEC analysis as easy and intuitive as possible. The software is laid out to guide the user through setup, data acquisition and analysis in an intuitive workflow. The software s advanced user interface reduces training requirements for new users. Software features Key features that make multi-detector analysis more valuable than ever include: Intuitive look and feel based upon the latest software tools Simple and customizable reporting to present only the data that is most important to you Overlay multiple injections and results quickly and easily Easy exporting of data 1-click from data to results! 9

VALIDATION AND SUPPORT Malvern s materials characterization technology and expertise enables scientists and engineers to understand and control properties of dispersed systems. Malvern s instruments are used to measure particle size, particle shape, zeta potential, molecular weight, size and conformation, rheology and for chemical identification. This information helps accelerate R&D, enhance product quality, optimize process efficiency. Areas we work in: ACADEMIC BIOCHEMICAL RESEARCH BIOPHARMACEUTICALS FOOD AND DRINK ASPHALT PHARMACEUTICAL COSMETICS AND PERSONAL CARE CHEMICALS MINING AND MINERALS POWER GENERATION CEMENT METAL POWDERS PLASTICS AND POLYMERS SURFACE COATINGS ELECTRONICS CERAMICS ADHESIVES AND SEALANTS Excellence through experience Many Malvern systems are used in highly regulated environments and product validation and R&D traceability are priorities for our customers. Operating to ISO9001: 2008 with TickIt accreditation for software development, Malvern is a major supplier to the highly demanding pharmaceutical and chemical industries. Malvern s products play pivotal roles in high quality research and manufacturing throughout the world. As a global supplier we believe we have responsibility to minimise the impact we have on the environment and operate to both ISO14001 and OHSA18001. Validation To help our customers comply with the requirements of the Regulatory Authorities, such as the US Food and Drugs Administration (FDA) and the Medicines and Healthcare Products Regulatory Agency (MHRA), Malvern provides a comprehensive range of validation tools. These aids follow a user s validation process through from Installation and Operational Qualification (IQ/OQ) to the maintenance phase with annual OQ renewals and the provision of standards for Performance Qualification (PQ). For products subject to FDA regulation, we have solutions to help with 21 CFR Part 11 compliance. World-class service and support Malvern offers professional support at all levels. Our intention is to increase your laboratory s productivity through the creation of a working relationship for the lifetime of your instrument providing service support, training and information. Global network of fully trained service personnel World-wide co-ordination for multi-national companies Technical support from the Malvern Helpdesk via telephone or email Range of maintenance contracts and service agreements to cover all requirements Validation support Consultancy-based on site training courses e-learning training courses via the internet Classroom training courses Web Seminars Sample and application consultancy. No other company offers more 10 www.malvern.com

SPECIFICATIONS OMNISEC Molecular Characterization System OMNISEC Molecular Characterization System Parameter Specification Parameter Specification OMNISEC SYSTEM OMNISEC REVEAL CONT. Parameters measured Sample types Concentration, dri, dn/dc, duv, da/dc, Light scattering intensity (SLS), Molecular weight (Mn, Mw, Mz), Polydispersity, Radius of Gyration, Intrinsic viscosity, Mark-Houwink a & K, Hydrodynamic radius (viscosity) Synthetic polymers, Natural polymers (polysaccharides, DNA), Proteins Principle Differential pressure dynamic range Differential pressure baseline noise 4-capillary Wheatstone bridge with self-balancing mechanism and userexchangeable capillaries ±2500 Pa 0.3 Pa Recommended computer specification Windows 7 Professional 64 bit, 4th Gen Intel Core I7 Processor (Quad Core HT, 3.4 GHz Turbo, w/hd Graphics, 8 GB 1600 MHz DDR3 memory, 500 GB 3.5 inch SATA (7200 RPM) HDD, Full-HD monitor 4-capillary differential viscometer Inlet pressure dynamic range Inlet pressure baseline noise Baseline drift 100 kpa 0.01 kpa <0.2 kpa Data collection rate 100 Hz Minimum quantifiable mass 1 μg of 100kDa molecular weight polystyrene in THF Patents US 14/599,033, US20140060162A1 & EP2619543B1, US20140144214A1 & EP2619544A1 Detector volume Delay volume volume 17 μl/capillary 8 ml per column Dimensions (W, D, H) OMNISEC REVEAL 42, 64, 60 cm Protection Firmware-based transducer overpressure protection Weight 40 kg OMNISEC RESOLVE Power requirements 600 W Dimensions (W, D, H) 42, 64, 89 cm Detector temperature control range Dynamic range Baseline noise 20-65 C ±2.5 x10-4 RIU <10-7 RIU Weight Power requirements Principle 62 kg 600 W Isocratic pump with continuous back seal washing Differential refractive index detector Diode-arraybased UV/Vis spectrometer Baseline drift Minimum quantifiable mass Flow cell volume Wavelength <3x10-7 RIU/hr 100 ng of 100kDa molecular weight polystyrene in THF 12 μl 640 nm Baseline noise 2x10-5 AU Baseline drift 5x10-4 AU/hr Wavelength range 190-900 nm Wavelength accuracy <1 nm Wavelength resolution 0.6 nm Number of wavelengths 1024 Flow cell volume 7.5 μl Path length 10 mm Pump Degasser Flow rate range 0.005-10 ml/min Flow rate accuracy ±1% Pressure range 0-5000 PSI (34.5 MPa) Pulsation 0.1456% @ 1 ml/min in water Degassing capacity >90% Volume 1850 μl Number of samples Up to 192 Sample container types HPLC vials; 96-well microtiter plates Temperature control range 4-60 C Injection volume range 1-300 μl Principle RALS/LALS Operating angles 90 & 7 Dynamic range 2500 mv Baseline noise <0.1 mv Autosampler Injection volume accuracy >99.5% <0.3% RSD in full loop mode Injection volume precision <0.5% RSD in partial loop mode <1% RSD in μl pickup mode Light scattering detector Baseline drift Minimum quantifiable mass Molecular weight range <0.2 mv/hr 100 ng of 100kDa molecular weight polystyrene in THF 200 - >10 7 g/mol Injection overhead volume Syringe volume 0 μl in μl pickup mode 250 μl standard Flow cell volume 18 μl Column capacity 6 x analytical (1 x Tricorn 10/300 GL) Laser Laser wavelength 50 mw 640 nm Column oven Temperature control range 20-65 C 11

Malvern Instruments Limited Grovewood Road, Malvern, Worcestershire, UK, WR14 1XZ Malvern Solutions: Advanced technology made simple - distributor details Tel +44 1684 892456 Fax +44 1684 892789 www.malvern.com Malvern Instruments is part of Spectris plc, the Precision Instrumentation and Controls Company. Spectris and the Spectris logo are Trade Marks of Spectris plc. All information supplied within is correct at time of publication. Malvern Instruments pursues a policy of continual improvement due to technical development. We therefore reserve the right to deviate from information, descriptions, and specifications in this publication without notice. Malvern Instruments shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance or use of this material. Malvern and the hills logo and OMNISEC, are International Trade Marks owned by Malvern Instruments Ltd. 2015 MRK2179-02