Nuclear Associates

Similar documents
ROC7080: RADIATION THERAPY PHYSICS LABORATORY LAB A : MECHANICAL MEASUREMENTS LINAC QA

Chapter 10 Acceptance Tests and Commissioning Measurements

GM Pancake Probe Victoreen Model D

Microsystems Technology Laboratories i-stepperthursday, October 27, 2005 / site map / contact

FOCUS 30/FOCUS 35 Field Calibration with Survey Pro Field Software

Read the following BEFORE getting started:

6. Radioactive Sources and IAEA Course Catalog

Simulation Modeling in Dosimetry

GM Pancake Probe Victoreen Model D

Evaluation of the truebeam machine performance check (MPC): mechanical and collimation checks

Design Considerations for a Variable Angle Absolute Reflectance Accessory For the LAMBDA 950/850/650 UV/Vis/NIR and UV/Vis Spectrophotometers

STANDARD: SPECIFICATION FOR PROTECTIVE ENCLOSURE AND CARRIER SYSTEMS USED TO TRANSPORT AND STORE ( INCH EUV RETICLES

566/568. Infrared Thermometers. Getting Started

Elcometer 116C. Sling Hygrometer. Operating Instructions

ASTM E545 TUTORIAL ON PROPER IMAGE QUALITY INDICATOR USAGE

Instrumental Quality Control of Therapeutic Linear Accelerator Performance

Owner's Manual NSL100B BUILDERS LEVEL NSL500B TRANSIT LEVEL

Introductory Statistics Neil A. Weiss Ninth Edition

ENGINEERING ASPECTS OF THE 200-INCH HALE TELESCOPE. Bruce Rule Mount Wilson and Palomar Observatories

FRAUNHOFER INSTITUTE FOR SURFACE ENGINEERING AND THIN FILMS IST ATMOSPHERIC PRESSURE PLASMA PROCESSES

MicroCell User manual

To gain a working knowledge of unit cells, packing efficiency, coordination numbers and their relationship to each other.

The Plus for your lab!

Model 556X User s Manual. Optical Isolator

Instructor s Advance Preparation

Owner's Manual. for AUTOMATIC LEVEL. NBL Series. FOR CUSTOMER SERVICE, PARTS & REPAIR, CALL Toll Free:

MICROSCOPE AND USE ANSWERS PRODUCTS MANUAL ARCHIVE

Eppendorf Vis Cuvettes. Instructions for use

SMP625 Product Specifications

Shielding Design for the Imaging and Medical Beamline at the Australian Synchrotron

AE3610 Experiments in Fluid and Solid Mechanics TRANSIENT MEASUREMENTS OF HOOP STRESSES FOR A THIN-WALL PRESSURE VESSEL

Tutorials. 1. Autocollimator. Angle Dekkor. General

KENYA BUREAU OF STANDARDS (KEBS)

The assessment and characterization of the built-in internal photometer of primary diagnostic monitors

TE 75R RESEARCH RUBBER FRICTION TEST MACHINE

Total Carboxylic Acid Group Content Applicable Products: Carbopol * Polymers and Pemulen * Polymeric Emulsifiers

1.25 Laser Collimator with 2 Adapter Instruction Manual SKU#

ISO 844 INTERNATIONAL STANDARD. Rigid cellular plastics Determination of compression properties

2 - Machining Fundamentals Measurement. Manufacturing Processes - 2, IE-352 Ahmed M El-Sherbeeny, PhD Spring-2015

Optics. Measuring the line spectra of inert gases and metal vapors using a prism spectrometer. LD Physics Leaflets P

Alignment of the Dipole Magnets in the Cornell Electron-Positron Storage Ring

DISCONTINUED PRECISION MEASURING FOWLER CALIPERS 1 - VERNIER CALIPERS 4 - ELECTRONIC CALIPERS

An accessory to the polarizing microscope for the optical examination of crystals.

XR Analog Clock - Manual Setting Model Troubleshooting Guide

Operating Instructions Validation Tool Kit, KT2 For use with USP Apparatus #1 & #2

SS V Subminiature, radial leaded, time-delay fuses

Laboratory Manual Physics_1. Index of refraction for solids

Use of a radioactive check device for redundancy check of ionization chambers

Metrology is science considering measurement

A New "Road Map" of the Heavens A long awaited publication event By: John Kraus

Multi-element process analyzer

Store User Guide - Forecasting. Jimmy John s

CIV : THEODOLITE ADJUSTMENT

THE JOINT EXAMINATION BOARD PAPER P6 INFRINGEMENT AND VALIDITY OF UNITED KINGDOM PATENTS a.m p.m.

INAYA MEDICAL COLLEGE (IMC) RAD LECTURE 1 RADIATION PHYSICS DR. MOHAMMED MOSTAFA EMAM

I. INTRODUCTION EXPERIMENTAL

AN INSTRUMENT FOR THE MEASUREMENT OF ROAD SURFACE REFLECTION PROPERTIES

NPN/PNP low V CEsat Breakthrough in Small Signal (BISS) transistor pair in a SOT457 (SC-74) Surface Mounted Device (SMD) plastic package.

INAYA MEDICAL COLLEGE (IMC) RAD LECTURE 1 RADIATION PHYSICS DR. MOHAMMED MOSTAFA EMAM

THE ACTIVE PERSONNEL DOSIMETER - APFEL ENTERPRISES SUPERHEATED DROP DETECTOR*

Objectives. Tolerance Limits and Action Levels for IMRT QA. The Overall Process of IMRT Planning and Delivery. Chain of IMRT Process

ABB temperature measurement Radiation thermometry. Measurement made easy. Process temperature measurement practice--non-contacting

Introduction. Earlier. To Scales. We talked about. L Dimensions

30 mm Diameter Main Tube

NPN/PNP transistor pair connected as push-pull driver in a SOT457 (SC-74) Surface-Mounted Device (SMD) plastic package.

MELOS 530 MEASURING EQUIPMENT FOR LENSES AND OPTICAL SYSTEMS. Combinations and Accessories. Indispensable for Quality Control of Optics

Ph 3455/MSE 3255 Experiment 2: Atomic Spectra

3M Petrifilm Lactic Acid Bacteria Count Plate

CFP PIANO SWITCHES (FULL PITCH) FEATURES APPLICATIONS PART NUMBER DESIGNATION C F P T B. RoHS compliant

PROVINCIAL HEALTH AUTHORITIES OF ALBERTA ACT

EVALUATION OF DYNAMIC METHODS FOR EARTHWORK ASSESSMENT

In data sheets and application notes which still contain NXP or Philips Semiconductors references, use the references to Nexperia, as shown below.

EUROMASTER HYDRAULIC PRESSBRAKES

THE use of radioactive isotopes in medical institutions is growing continuously.

0.5 (.020) (.051) 0.2 (.008) min 0.2 (.008) min

THE mono-energetic hadron beam such as heavy-ions or

Applications Note 202 October 2008

Development of Laser Thickness Gauge in Steel Plate Shearing Line

Course: Technology II Training course topic: Metrology

Measurement of electric potential fields

International Journal of Advance Engineering and Research Development

Pseudorandom Coding Techniques for Position Measurement

The New Eppendorf X-Drive - Maximum Performance, Flexibility and Longevity for Demanding Shaker Tasks

LUXEON Z. Industry s smallest high power emitter for use in close-packed applications requiring an undomed solution ILLUMINATION

Time-resolved beam symmetry measurement for VMAT commissioning and quality assurance

Progress in Nuclear Science and Technology, Volume 6,

Leveling. 3.1 Definitions

ISO INTERNATIONAL STANDARD. Rolling bearings Linear motion rolling bearings Part 2: Static load ratings

Avery Dennison LW Series Retroreflective Window Sticker Film Issued: July 2013

ST-32 SURFACE MOUNT CERMET TRIMMERS (SINGLE TURN) S T E T A ( 1 2 ) FEATURES PART NUMBER DESIGNATION

Resin-Molded, Radial-Lead Solid Tantalum Capacitors

Memorandum. Air Sampling

White Paper FINAL REPORT AN EVALUATION OF THE HYDRODYNAMICS MECHANISMS WHICH DRIVE THE PERFORMANCE OF THE WESTFALL STATIC MIXER.

Validation of LS-DYNA MMALE with Blast Experiments

Solid-state physics. Laue diagrams: investigating the lattice structure of monocrystals. LEYBOLD Physics Leaflets P

How to Make or Plot a Graph or Chart in Excel

Platinum SMD Flat Chip Temperature Sensor

Magnet Buildability Review report : C-Beta Magnets

AERODROMES PANEL (AP) VISUAL AIDS WORKING GROUP (VAWG) FIFTH MEETING. Montréal, Canada, 25 to 27 June 2008

30 mm Diameter Main Tube 1-4x24 Models

Transcription:

Nuclear Associates 37-001 TEL-ALIGN Teletherapy Alignment Gauge Users Manual March 2005 Manual No. 37-001-1 Rev. 2 2004, 2005 Fluke Corporation, All rights reserved. Printed in U.S.A. All product names are trademarks of their respective companies

Fluke Biomedical Radiation Management Services 6045 Cochran Road Cleveland, Ohio 44139 440.498.2564 www.flukebiomedical.com/rms

Table of Contents Section 1: Introduction... 1-1 1.1 Introduction... 1-1 1.2 Equipment Required... 1-1 1.3 Test Procedure... 1-1 1.4 Evaluation... 1-1 1.5 Evaluation Results... 1-2 i

(Blank page)

Introduction Introduction 1 Section 1 Introduction 1.1 Introduction Precise radiation therapy requires treatment geometry that is accurate and reproducible. Since machine parameters can easily become misaligned, they should be checked frequently. The TEL-ALIGN Teletherapy Alignment Gauge* permits a quick check of these parameters and facilitates the adjustment of those which require realignment. It is especially useful in an overall QA program. 1.2 Equipment Required The TEL-ALIGN consists of a rectangular plastic base, 17 cm x 16 cm x 5 cm, with a removable vertical scale, 18 cm high. The base is placed on the treatment table and leveled, using the adjusting pads and the circular bubble level. The upper surface of the base contains lead markers that form a square (10 cm x 10 cm) for visualization on film. A crosshair in the center of the square lines up with two additional sets of crosshairs, one on each outer edge of the base. a. TEL-ALIGN Teletherapy Alignment Gauge b. Ready-Pack Localization Film 1.3 Test Procedure A. Place the central axis of the gantry in a vertical position. Set all angles (head rotation, gantry, collimator and treatment couch at 0 position. B. Set a 10 cm x 10 cm field size at isocenter. C. Place the TEL-ALIGN base plate on the Mylar portion of the table. Position and level the plate symmetrically with the 10 cm x 10 cm light field. D. Position the top surface of the TEL-ALIGN at the isocenter distance. 1.4 Evaluation A. Optical Distance Indicator (ODI) Place the vertical ODI scale on the base plate. The coincidence of the machine's ODI scale can then be checked with the TEL-ALIGN scale. The vertical scale can then be removed. B. Collimator Field size and crosshairs should coincide with the TEL-ALIGN, indicating proper alignment. The symmetry of the collimator jaws, the alignment of the crosshairs, and angle indicators can be checked at 90 increments by rotating the collimator. *Designed and developed by the Medical Physics Department, Memorial Sloan Kettering Hospital, New York, NY 10021. 1-1

Nuclear Associates 37-001 Operators Manual C. Head Rotation and Pitch By exercising these motions and returning to the zero settings, the accuracy of the zero indicator or interlock can be demonstrated by observing the coincidence of the machine crosshairs with the TEL-ALIGN. D. Isocenter By rotating the gantry from 0 to 90, 180 and 270, any variation of coincidence can be tracked by the projection of the crosshairs and corresponding crosses on the TEL-ALIGN. E. Side Lights and/or Back Pointer Projection and intersection of the corresponding crosses at 0, 90, 180 and 270 will demonstrate alignment. F. Light Field vs. Radiation Field Ready-pack film is placed under the TEL-ALIGN gauge, and an appropriate exposure is given. The coincidence of the radiation field edges, with the embedded lead markers in the gauge, can then be verified on the developed film. 1.5 Evaluation Results The allowed tolerance for alignment of the above parameters is usually of the order of 1-2 mm. However, the manufacturer's specifications should be consulted for a specific machine. When the tests demonstrate misalignment, adjustments can be made to the unit with the TEL-ALIGN in position on the table. 1-2

(Blank page)

Fluke Biomedical Radiation Management Services 6045 Cochran Road Cleveland, Ohio 44139 440.498.2564 www.flukebiomedical.com/rms