THE UNIVERSITY OF NEW SOUTH WALES. School of Electrical Engineering & Telecommunications FINALEXAMINATION. Session

Similar documents
B.E. / B.Tech. Degree Examination, April / May 2010 Sixth Semester. Electrical and Electronics Engineering. EE 1352 Power System Analysis

KINGS COLLEGE OF ENGINEERING Punalkulam

Introduction to Synchronous. Machines. Kevin Gaughan

EE 6501 POWER SYSTEMS UNIT I INTRODUCTION

EE2351 POWER SYSTEM ANALYSIS UNIT I: INTRODUCTION

POWER SYSTEM STABILITY

ELG4125: Power Transmission Lines Steady State Operation

EE 742 Chapter 3: Power System in the Steady State. Y. Baghzouz

ECE 476. Exam #2. Tuesday, November 15, Minutes

EE 451 Power System Stability

Module 3 : Sequence Components and Fault Analysis

Three Phase Circuits

INSTITUTE OF AERONAUTICAL ENGINEERING (Autonomous)

The Operation of a Generator on Infinite Busbars

Final Exam, Second Semester: 2015/2016 Electrical Engineering Department

Chapter 3 AUTOMATIC VOLTAGE CONTROL

SSC-JE EE POWER SYSTEMS: GENERATION, TRANSMISSION & DISTRIBUTION SSC-JE STAFF SELECTION COMMISSION ELECTRICAL ENGINEERING STUDY MATERIAL

DHANALAKSHMI SRINIVASAN COLLEGE OF ENGINEERING AND TECHNOLOGY Mamalapuram Chennai QUESTION BANK V SEMESTER. EE6501-Power system Analysis

EE2351 POWER SYSTEM OPERATION AND CONTROL UNIT I THE POWER SYSTEM AN OVERVIEW AND MODELLING PART A

IGEE 402 Power System Analysis. FINAL EXAMINATION - SAMPLE Fall 2004

Chapter 8: Unsymmetrical Faults

QUESTION BANK ENGINEERS ACADEMY. Power Systems Power System Stability 1

Generators. What its all about

Transmission and Distribution of Electrical Power

ECE 325 Electric Energy System Components 7- Synchronous Machines. Instructor: Kai Sun Fall 2015

Lesson 17: Synchronous Machines

Synchronous Machines

Fault Calculation Methods

LESSON 20 ALTERNATOR OPERATION OF SYNCHRONOUS MACHINES

ECE 585 Power System Stability

ELECTRIC POWER CIRCUITS BASIC CONCEPTS AND ANALYSIS

SHORT QUESTIONS AND ANSWERS. Year/ Semester/ Class : III/ V/ EEE Academic Year: Subject Code/ Name: EE6501/ Power System Analysis

Fault Analysis Power System Representation

Exercise Dr.-Ing. Abdalkarim Awad. Informatik 7 Rechnernetze und Kommunikationssysteme

Electromagnetic Energy Conversion Exam 98-Elec-A6 Spring 2002

Last Comments on Short-Circuit Analysis

ECEN 460 Exam 1 Fall 2018

SESSION 3. Short Circuit Calculations, Unsymmetrical Faults. Leonard Bohmann, Michigan State University Elham Makram, Clemson University

POWER SEMICONDUCTOR BASED ELECTRIC DRIVES

SECTION 7: FAULT ANALYSIS. ESE 470 Energy Distribution Systems

1 Unified Power Flow Controller (UPFC)

Module 3 : Sequence Components and Fault Analysis

Chapter 4. Synchronous Generators. Basic Topology

GATE SOLVED PAPER - EE

Generation, transmission and distribution, as well as power supplied to industrial and commercial customers uses a 3 phase system.

BASIC PRINCIPLES. Power In Single-Phase AC Circuit

CHAPTER 2 DYNAMIC STABILITY MODEL OF THE POWER SYSTEM

Incorporation of Asynchronous Generators as PQ Model in Load Flow Analysis for Power Systems with Wind Generation

EE Branch GATE Paper 2010

BEE701 POWER SYSTEM ANALYSIS

ECE 476 Power System Analysis Fall 2014 Exam #1, Thursday, October 2, :30AM - 10:50AM

Comparative Study of Synchronous Machine, Model 1.0 and Model 1.1 in Transient Stability Studies with and without PSS

SCHOOL OF ELECTRICAL, MECHANICAL AND MECHATRONIC SYSTEMS. Transient Stability LECTURE NOTES SPRING SEMESTER, 2008

EDSA IEC 909 SHORT CIRCUIT ANALYSIS

Chapter 9: Transient Stability

EE2351 POWER SYSTEM ANALYSIS

MODULE TITLE : ELECTRICAL SUPPLY AND DISTRIBUTION SYSTEMS

EE 3120 Electric Energy Systems Study Guide for Prerequisite Test Wednesday, Jan 18, pm, Room TBA

LO 1: Three Phase Circuits

Equivalent Circuits with Multiple Damper Windings (e.g. Round rotor Machines)

Fault Locating PRESENTED BY ERIK SCHELLENBERG IDAHO POWER

Lecture (5) Power Factor,threephase circuits, and Per Unit Calculations

JRE SCHOOL OF Engineering

GATE 2008 Electrical Engineering

Transformer. Transformer comprises two or more windings coupled by a common magnetic circuit (M.C.).

Power System Stability and Control. Dr. B. Kalyan Kumar, Department of Electrical Engineering, Indian Institute of Technology Madras, Chennai, India

GATE 2010 Electrical Engineering

ECE 421/521 Electric Energy Systems Power Systems Analysis I 3 Generators, Transformers and the Per-Unit System. Instructor: Kai Sun Fall 2013

ECE 420. Review of Three Phase Circuits. Copyright by Chanan Singh, Panida Jirutitijaroen, and Hangtian Lei, For educational use only-not for sale.

Electrical Machines-I Prof. D. Kastha Department of Electrical Engineering Indian Institute of Technology, Kharagpur

Chapter 8 VOLTAGE STABILITY

Prince Sattam bin Abdulaziz University College of Engineering. Electrical Engineering Department EE 3360 Electrical Machines (II)

POWER SYSTEM STABILITY AND CONTROL

DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING QUESTION BANK

Dynamic simulation of a five-bus system

A. P. Sakis Meliopoulos and George J. Cokkinides Power System Relaying, Theory and Applications. Chapter 8 2 Generator Protection 2

An Introduction to Electrical Machines. P. Di Barba, University of Pavia, Italy

3 d Calculate the product of the motor constant and the pole flux KΦ in this operating point. 2 e Calculate the torque.

Contents Kreatryx. All Rights Reserved.

Three-phase AC Circuits. Measurement of Power in a Three-phase Circuit

ECEN 667 Power System Stability Lecture 18: Voltage Stability, Load Models

Regulating Transformers in Sequence Domain

The Effects of Mutual Coupling and Transformer Connection Type on Frequency Response of Unbalanced Three Phases Electrical Distribution System

4 Fault Calculations. Introduction 4.1. Three phase fault calculations 4.2. Symmetrical component analysis 4.3 of a three-phase network

Dynamics of the synchronous machine

Chapter 6. Induction Motors. Copyright The McGraw-Hill Companies, Inc. Permission required for reproduction or display.

ROEVER COLLEGE OF ENGINEERING & TECHNOLOGY ELAMBALUR, PERAMBALUR DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING ELECTRICAL MACHINES I

Power System Analysis Prof. A. K. Sinha Department of Electrical Engineering Indian Institute of Technology, Kharagpur

Power System Stability GENERATOR CONTROL AND PROTECTION

PowerApps Optimal Power Flow Formulation

Symmetrical Components. References

CHAPTER 2 CAPACITANCE REQUIREMENTS OF SIX-PHASE SELF-EXCITED INDUCTION GENERATORS

mywbut.com Lesson 16 Solution of Current in AC Parallel and Seriesparallel

Symmetrical Fault Current Calculations Unlv

In the previous chapter, attention was confined

DESIGNING POWER SYSTEM STABILIZER WITH PID CONTROLLER

The Effect of the Harmonics, the Fault Location and the Fault Resistance on the Performance of the Impedance-Type Distance Relay

Single Phase Parallel AC Circuits

Australian Journal of Basic and Applied Sciences. General Fault Admittance Method Solution of a Balanced Line-to-Line-to-Line Fault

Transmission Lines. Plane wave propagating in air Y unguided wave propagation. Transmission lines / waveguides Y. guided wave propagation

Transcription:

Name: Student ID: Signature: THE UNIVERSITY OF NEW SOUTH WALES School of Electrical Engineering & Telecommunications FINALEXAMINATION Session 00 ELEC46 Power System Analysis TIME ALLOWED: 3 hours TOTAL MARKS: 00 TOTAL NUMBER OF QUESTIONS: 5 THIS EXAM CONTRIBUTES 65%TO THE TOTAL COURSE ASSESSMENT. Reading Time: 0 minutes. This paper contains 7 pages. Candidates mustattempt ONLY 4questions. Answer each question in a separate answer book. Marks for each question are indicated beside the question. This papermaybe retained by the candidate. Print your name, student ID and question number on the front page of each answer book. Authorised examination materials: Drawing instruments may be brought into the examination room. Candidates should use their own UNSW-approved electronic calculators. This is a closed book examination. Assumptions made in answering the questions should be stated explicitly. All answers must be written in ink. Except where they are expressly required, pencils may only be used for drawing, sketching or graphical work.

INFORMATION SHEET Three-phase -connected loads AB, BC, CA can be transformed into equivalent Y- connected loads,, and vice versa: A B C A B B C C A A B B C C A AB ; BC C A A ABCA AB BC CA Round-rotor synchronous generator: AB BC CA ; CA AB BC BC CA ; B ; C AB BC CA AB BC CA B E f + _ jx s I t + V t _ V It It E E 0 t Vt 0 (ref. phasor) f f Power output: VE t f P sin ; x s VE V Q cos x x t f t Given any unbalanced 3-phase sequence X a, Xb, X c, we can find the positive, negative and zero sequences,,,, X, X, X, and it can be shown that: Xa Xb X c, Xa Xb X c, and 0a 0b 0c X X a 0a Xb a a Xa X c a a X a and s X X 0a a Xa a a Xb 3 X a a a X c The zero sequence impedance representations for various transformer connections are shown below: s Winding connection ero sequence impedance representation per phase 0 0

QUESTION [5 marks ] Briefly answer the following questions: What are the main objectives of this course on power system analysis? (ii) Explain how the per-unit method is applied in analysing power circuits and the advantages of using such a method (iii) Within the context of power system operation and control, state the operational objectives, operating constraints, and power system control variables. (iv) What is meant by triplen harmonics? Is it possible to have triplen harmonics in line-to-line voltages in a three-phase system? Is it possible to have triplen harmonic current in Y-connected systems? [0 marks] (b) The schematic diagram of a three-phase transmission system is shown in Figure below. Using per-unit normalization with base values of 00 MVA and 3 kv for the transmission line, draw the equivalent circuit of the system, show per-unit values for all the components, and calculate the terminal voltage V S of the generator. Figure [7 marks] (c) A 50-km, 30-kV, three-phase transmission line has a positive-sequence series impedance z 0.06 j0.4 /km and shunt admittance y j.5 0 6 S/km. At the load end, the line delivers 50MW at 0.9 power factor lagging and at 95% of rated voltage. (ii) Show the -model equivalent circuit for this transmission line. Derive the formulas for its -port ABCD parameters. Calculate the sending-end voltage. 3

QUESTION [5 marks ] Briefly answer the following questions: What is surge impedance loading? Discuss the effect of the termination load on the voltage profile across a lossless transmission line and explain the effect of reactive compensation. (ii) Discuss the power system response to short-circuit faults in relation to different time scales. (iii) Explain the reason behind the use of symmetrical components for analysing unbalanced three-phase faults. (iv) Discuss the stability of synchronous generators in relation to the operating power angle. [0 marks] (b) Consider the -Y connected transformer shown in Figure. Suppose that the transformer is ideal and that the supply phase sequence is ABC. Using sketches of the appropriate phasor diagrams, find the phase difference betweenv AB and V ab (i.e. the difference between the angles of the two phasors). Indicate which quantity leads. a A a A C b b a B C A B B C c c c b Figure [5 marks] (c) A three-phase round-rotor synchronous generator is rated at 3. kv, 00 MW at 0.8 power factor lagging. It has a synchronous reactance of per phase. The stator resistance is negligible. The excitation losses are also negligible. (ii) The generator is connected to an infinite bus and is delivering its rated power at unity power factor. Find the excitation voltage, the power angle, and the reactive power. The field excitation current is maintained as in and the prime mover power into the generator is reduced by 50%. Find the new operating conditions (real and reactive power, power angle, armature current, and power factor). [0 marks] 4

QUESTION 3[5 marks ] Bus k is connected to bus i via a transmission line as shown in Figure 3. Derive the expressions for the power flow (real and reactive) from bus k towards bus i in terms of the bus voltages (V k, V i ) and phase angle difference across the line. Bus k Bus i ki k i P ki jq ki jx ki I ki V k V k k V i V i i Figure 3 For the system shown in Figure 4, find Q so that V and for such a case, what is. j0.5 P Q V 0 o V Figure 4 [5 marks] (b) Figure 5 shows a single-line diagram of a four-bus power system. Branch series reactances and busbar loads are given in per-unit on a common base. Branch series resistances and shunt reactances are neglected. Bus is chosen as the slack bus for power flow analysis. V=.0 j0.pu j0.pu 4 j0.4pu P=0. V=.0 Determine the 4 4 j0.5pu j0.pu P=0.5 Q=0. 3 P=0.4 Q=0. Figure 5 Y. per-unit bus admittance matrix (ii) For each bus k,, 3, 4 state which of the variables P, Q, V, are input data and which are unknown. Write the power flow equations for bus 3. [0 marks] 5 ki k k k k

QUESTION 4[5 marks ] G T TL T G TL3 TL3 3 Figure 6 Consider the three-phase power system shown in Figure 6. The equipment ratings and perunit reactances are given as follows: Synchronous generator G: 0MVA, 5kV, X 0 = 0.05, X = X = 0. Synchronous generator G: 00MVA, 3.8kV, X 0 = 0.05, X = X = 0. Power transformer T: 00MVA, 5kV Y / 30kV Y, X 0 = X = X = 0.05 Power transformer T: 00MVA, 3.8kV / 30kV Y, X 0 = X = X = 0.05 Tx lines TL, TL3, TL3: 00MVA, 30kV, X = X = 0., X 0 = 0.3 All the generators are Y connected and the star points are grounded through a reactance of 0.03 p.u. All the transformer star points are solidly grounded. (b) (c) Construct the per-unit positive, negative and zero sequence reactance diagrams. Use the 00MVA, 30kV base for the transmission lines. Neglect the -Y transformer phase shifts. A fault occurred at bus 3. Determine the Thevenin equivalent of each sequence network as viewed from the fault bus. Prefault voltage is.0 per unit. Prefault load currents and -Y phase shifts can be neglected. [6 marks] Determine the sub-transient fault current in per-unit and in ka during a bolted threephase fault at bus 3. [5 marks] (d) For a bolted single line-to-ground fault at bus 3, determine the sub-transient fault current in per-unit and in ka, and the (phase) voltages at the fault. [6 marks] 6

QUESTION 5[5 marks ] Two generators supply a total load of 700MW. The generator fuel costs are as follows: G: C 900 45P 0.0P $/hr (where P G is in MW) G: G G C 500 43P 0.003P $/hr (where P G is in MW) G G If there are no constraints on generator outputs, find the power delivered by each generator so that the total fuel cost is minimum. What is the average cost in cents per kwh at this operating condition? (ii) Now suppose that the maximum output power of each generator is 600MW. Taking this constraint into consideration, find the optimal dispatch. (iii) Find the system incremental cost for the two cases above. Comment on the results. [9 marks] (b) Briefly answer the following questions: Provide a functional description of the different types of protection relays. (ii) With the aid of Figure 7, explain how two-zone protection system works. Figure 7 (c) A single phase, 5 MVA, 0/8.66 kv transformer is protected by a differential relay with taps. Standard CT ratios are 5:50, 5:00, 5:50, 5:00, 5:50, 5:300, 5:400, 5:450, 5:500, 5:600, 5:800, 5:900, 5:000, 5:00. Available relay tap settings are 5:5, 5:5.5, 5:6.6, 5:7.3, 5:8, 5:9 and 5:0. Select appropriate CT ratios, and relay tap settings. Also, determine the percentage mismatch for the selected tap setting. END OF EXAMINATION PAPER 7