Cloud-to-Ground Lightning Production in Strongly Forced, Low- Instability Convective Lines

Similar documents
Anthony A. Rockwood Robert A. Maddox

Summary of November Central U.S. Winter Storm By Christopher Hedge

Summary of High Wind Event of 7 March 2004

P3.17 THE DEVELOPMENT OF MULTIPLE LOW-LEVEL MESOCYCLONES WITHIN A SUPERCELL. Joshua M. Boustead *1 NOAA/NWS Weather Forecast Office, Topeka, KS

1. INTRODUCTION * Figure 1. National Weather Service Storm Prediction Center (SPC) storm reports for December 1, 2006.

Charles A. Doswell III, Harold E. Brooks, and Robert A. Maddox

Kenneth L. Pryor* and Gary P. Ellrod Center for Satellite Applications and Research (NOAA/NESDIS) Camp Springs, MD

Mid-Latitude Cyclones and Fronts. Lecture 12 AOS 101

Chapter 14 Thunderstorm Fundamentals

Science Olympiad Meteorology Quiz #2 Page 1 of 8

and 24 mm, hPa lapse rates between 3 and 4 K km 1, lifted index values

A Detailed Analysis of a Long-Tracked Supercell. Jason T. Martinelli and Andrew Elliott. Fred Glass

P12.7 MESOCYCLONE AND RFD INDUCED DAMAGING WINDS OBSERVED IN THE 27 MAY 2004 SOUTHWEST OHIO SUPERCELL

CHAPTER 11 THUNDERSTORMS AND TORNADOES MULTIPLE CHOICE QUESTIONS

P12.6 Multiple Modes of Convection in Moderate to High Wind Shear Environments

10/21/2012. Chapter 10 Thunderstorms. Part II. Growth and Development of ordinary Cell Thunderstorms Thunderstorm Electrification.

Weather Systems III: Thunderstorms and Twisters

Foundations of Earth Science, 6e Lutgens, Tarbuck, & Tasa

Investigating the Environment of the Indiana and Ohio Tornado Outbreak of 24 August 2016 Using a WRF Model Simulation 1.

11A.2 Forecasting Short Term Convective Mode And Evolution For Severe Storms Initiated Along Synoptic Boundaries

Chapter 3 Convective Dynamics 3.4. Bright Bands, Bow Echoes and Mesoscale Convective Complexes

Refer to Figure 1 and what you have learned so far in this course when responding to the following:

Synoptic Meteorology II: Frontogenesis Examples Figure 1

April 13, 2006: Analysis of the Severe Thunderstorms that produced Hail in Southern Wisconsin

Observation Homework Due 11/24. Previous Lecture. Midlatitude Cyclones

Multiscale Analyses of Inland Tropical Cyclone Midlatitude Jet Interactions: Camille (1969) and Danny (1997)

Severe Weather Event of 13 July 2014

Module 11: Meteorology Topic 6 Content: Severe Weather Notes

4/29/2011. Mid-latitude cyclones form along a

3A.4 AN ANALYSIS OF THE ELEVATED MIXED LAYER DURING THE SUPER TUESDAY OUTBREAK

True or false: The atmosphere is always in hydrostatic balance. A. True B. False

ATS 351, Spring 2010 Lab #11 Severe Weather 54 points

ANSWER KEY. Part I: Synoptic Scale Composite Map. Lab 12 Answer Key. Explorations in Meteorology 54

Synoptic Meteorology II: Petterssen-Sutcliffe Development Theory Application March 2015

Isolated severe weather and cold air damming 9 November 2005 By Richard H. Grumm National Weather Service Office State College, PA 16801

Air Masses, Fronts, Storm Systems, and the Jet Stream

MET 3502 Synoptic Meteorology. Lecture 8: September 16, AIRMASSES, FRONTS and FRONTAL ANALYSIS (2)

Jonathan M. Davies* Private Meteorologist, Wichita, Kansas

Tornadogenesis in Supercells: The Three Main Ingredients. Ted Funk

Multi-day severe event of May 2013

Quasi-Geostrophic Implications

Solutions to Comprehensive Final Examination Given on Thursday, 13 December 2001

TOPICS: What are Thunderstorms? Ingredients Stages Types Lightning Downburst and Microburst

1. Which weather map symbol is associated with extremely low air pressure? A) B) C) D) 2. The diagram below represents a weather instrument.

Chapter 12 Fronts & Air Masses

Weather report 28 November 2017 Campinas/SP

Cloud-to-Ground Lightning Production in Strongly Forced, Low-Instability Convective Lines Associated with Damaging Wind

Final Examination, MEA 443 Fall 2008, Lackmann

THE MAP ROOM. BAND ON THE RUN Chasing the Physical Processes Associated with Heavy Snowfall

Severe Weather with a strong cold front: 2-3 April 2006 By Richard H. Grumm National Weather Service Office State College, PA 16803

b. The boundary between two different air masses is called a.

Steve Keighton * and Steve Nogueira NOAA/NWS Blacksburg, VA. Nicole Belk NOAA/NWS Charleston, WV

Talking points for Water Vapor Imagery Analysis for Severe Thunderstorm Forecasting.

WISCONSIN TORNADO OUTBREAK OF 18 AUGUST 2005: AN EXAMINATION OF THE VIOLA, WISCONSIN TORNADO

Evolution and Maintenance of the June 2003 Nocturnal Convection

Lecture Outlines PowerPoint. Chapter 19 Earth Science 11e Tarbuck/Lutgens

Earth Science, 11e. Weather Patterns and Severe Storms Chapter 19. Air masses. A cold Canadian air mass Figure Air masses. Air masses 9/5/2012

IOP-2 Summary of Operations 03 June UTC 04 June UTC Authors: Market, Kastman

Case Study 3: Dryline in TX and OK 3 May 1999

Impacts of the April 2013 Mean trough over central North America

Practical Use of the Skew-T, log-p diagram for weather forecasting. Primer on organized convection

National Wildland Significant Fire Potential Outlook

Shear-Parallel Mesoscale Convective Systems in a Moist Low- Inhibition Mei-Yu Front Environment. Liu and Moncrieff (2017 JAS)

Satellites, Weather and Climate Module??: Polar Vortex

Type of storm viewed by Spotter A Ordinary, multi-cell thunderstorm. Type of storm viewed by Spotter B Supecell thunderstorm

Weather Patterns and Severe Storms

Current Weather Studies 4 TEMPERATURE AND AIR MASS ADVECTION

Chapter 1 Anatomy of a Cyclone

P1.22 A FIVE-YEAR CLIMATOLOGY OF ELEVATED SEVERE CONVECTIVE STORMS IN THE UNITED STATES EAST OF THE ROCKY MOUNTAINS

National Weather Service-Pennsylvania State University Weather Events

Fronts in November 1998 Storm

Science Olympiad Meteorology Quiz #1 Page 1 of 7

1 August 2006 An Investigation of a Bow Echo along the Wasatch Front. Randy Graham and Chris Gibson 6 April 2007

p = ρrt p = ρr d = T( q v ) dp dz = ρg

Warm season forecasting! Some material adapted from Material Produced at COMET for their Residence Course in Hydrometeorology

Inner core dynamics: Eyewall Replacement and hot towers

A COMPREHENSIVE 5-YEAR SEVERE STORM ENVIRONMENT CLIMATOLOGY FOR THE CONTINENTAL UNITED STATES 3. RESULTS

Investigation of the Arizona Severe Weather Event of August 8 th, 1997

WARM SECTOR TORNADOES WITHOUT DISCERNIBLE SURFACE BOUNDARIES AND WITH MINIMAL DEEP LAYER SHEA

11B.1 INFLUENCE OF DIABATIC POTENTIAL VORTICITY ANOMALIES UPON WARM CONVEYOR BELT FLOW. PART I: FEBRUARY 2003

Analysis of Severe Storm Initiation Along Drylines in the Southern Plains

contact with ground for 1 hour plus, starting 1500 MDT moved N., covered about 37 km width varied m

Test Form: A Key Final Exam: Spring 2011

Chapter 21. Weather Patterns and Severe Storms

Meteorology Lecture 18

THE SYNOPTIC ENVIRONMENT OF THE 11 APRIL 2001 CENTRAL PLAINS TORNADO OUTBREAK VIEWED IN THREE DIMENSIONS

Department of Geosciences San Francisco State University Spring Metr 201 Monteverdi Quiz #5 Key (100 points)

Feel free to ask me if you are confused about the meaning of any question. Good luck, and have a great spring break!

DEPARTMENT OF EARTH & CLIMATE SCIENCES NAME SAN FRANCISCO STATE UNIVERSITY Fall ERTH FINAL EXAMINATION KEY 200 pts

1 of 7 Thunderstorm Notes by Paul Sirvatka College of DuPage Meteorology. Thunderstorms

1A.1 A UNIQUE COLD-SEASON SUPERCELL PRODUCES AN EF1 SNOWNADO

Lower-Tropospheric Height Tendencies Associated with the Shearwise and Transverse Components of Quasigeostrophic Vertical Motion

Answers to Clicker Questions

Paul Yura*, Frank Alsheimer, and Joseph Calderone NOAA, National Weather Service Forecast Office, Charleston South Carolina 1.

Joshua M. Boustead *1 NOAA/NWS WFO Omaha/Valley, NE. Philip N. Schumacher NOAA/NWS WFO Sioux Falls, SD

National Weather Service-Pennsylvania State University Weather Events

Part. I Introduction. Part II Scale Characteristics and Climatology of MCSs

THE DEEPENING OF A LOW-LEVEL TROUGH AS INDICATED BY DUST ALOFT IN GOES ' INFRARED PICTURES

Chapter 9. Weather Patterns & Midlatitude Cyclones

P1.1 BAROCLINICITY INFLUENCES ON STORM DIVERGENCE IN THE SUBTROPICS

Transcription:

Cloud-to-Ground Lightning Production in Strongly Forced, Low- Instability Convective Lines Matthew S. Van Den Broeke National Weather Center Research Experiences for Undergraduates, and Valparaiso University Valparaiso, Indiana David M. Schultz (Mentor) CIMMS, OU and NOAA/NSSL Norman, Oklahoma Robert H. Johns (Mentor) Norman, Oklahoma Jeffry S. Evans (Mentor) NOAA/NWS/NCEP/SPC Norman, Oklahoma John E. Hales (Mentor) NOAA/NWS/NCEP/SPC Norman, Oklahoma July 30, 2004 Corresponding author: M.S. Van Den Broeke 8463 Elevator Road Roscoe, IL 61073 Email: Matthew.VanDenBroeke@Valpo.edu Phone: 815-623-8463

Abstract On 9 November 1998, a convective line initiated over Oklahoma along a cold front in a moderately unstable environment. The line moved east into an area of low to zero instability during 10 and 11 November 1998, yet continued producing damaging surface wind gusts. After moving into weaker instability, the strongly forced, lowinstability convective line quit producing cloud-to-ground (CG) lightning as detected by the National Lightning Detection Network (NLDN). This paper seeks to explain the evolution of CG lightning in this case, the maintenance of the convective line in a lowinstability environment, and the production of damaging surface winds. On 9 March 2002, a similar case occurred. Lightning production in this case is documented, and other similarities between this and the 9-11 November 1998 case are noted. 1

1. Introduction Mesoscale convective systems (MCSs) occasionally occur in which many severe wind reports are received, yet very little cloud-to-ground (CG) lightning is detected by the National Lightning Detection Network (NLDN). Such MCSs often occur during the winter season in low instability environments with strong dynamics, and take the form of strongly forced, low-instability convective lines. These convective lines pose a dilemma for forecasters: severe thunderstorm watches and warnings do not seem appropriate because CG lightning is absent, but advisories for strong wind do not seem appropriate either because this wind does not occur on the synoptic scale. On 9 November 1998, a cyclone formed over the southern Plains, and began to rapidly deepen on 10 November. At 21 UTC 9 November, a convective line formed along the cyclone s cold front in the Texas and Oklahoma panhandles. As this line moved across the United States it quit producing observed CG lightning, yet produced widespread wind damage from north Texas to eastern Ohio (Fig. 1). The purpose of this paper is to understand the production of CG lightning in strong forced, low-instability convective lines. Section 2 will discuss the evolution of the 9-11 November 1998 case, including lightning production, maintenance of the convective line in a low CAPE environment, and how winds meeting severe criteria, defined as 25.7 m s -1 (50 knots), reached the surface. Section 3 examines lightning production in the similar case of 9-10 March 2002. Section 4 concludes this paper. 2

2. 10-11 November 1998 In this section, the 10-11 November 1998 case is examined chronologically, beginning 00 UTC 10 November and ending 00 UTC 11 November. Section 2a covers the time during which frequent CG lightning was observed with the convective line. By 12 UTC 10 November, the line made a transition to producing nearly no observable CG lightning, and at the same time began producing more widespread damaging winds. Section 2b will discuss environmental conditions that allowed the line to make this transition. Finally, section 2c will describe how the convective line dissipated. a. Frequent CG Lightning Phase At 00 UTC 10 November, a large-amplitude 500-mb trough moved out of the Rockies, with strong diffluence developing over much of the Plains (Fig. 2a). An axis of 45 m s -1 flow was rounding the base of the 500-mb trough. A 992-mb low was centered over central Kansas (Fig. 3a). The ascending branch of the frontal circulation associated with the cyclone s cold front aided in the development of the convective line (Fig. 4c) (Connors 1999), which was located from the low center southwest into north-central Texas (Fig. 4a). According to MacGorman and Rust (1998, 218-220), vigorous updrafts must be present in the mixed-phase region of the cloud, defined as that portion of the cloud between 10ûC and 40ûC, for sufficient charge separation to occur for the production of CG lightning. To test the requirements for lightning production, the 10ûC and 40ºC isotherms were located on observed soundings. Vertical distribution of convective available potential energy (CAPE) was examined, and updraft potential in the convective line s mixed-phase region was inferred based on vertical distribution of stability. 3

The convective line was producing frequent CG lightning early in its lifetime as detected by the NLDN (Fig. 4b). The 00 UTC 10 November KOUN sounding supported this observation (Fig. 4d): the 10ûC isotherm was located at approximately 550 mb, while the equilibrium level (EL) pressure was 189 mb and temperature was 64ºC. Cloud top temperatures estimated from satellite observations ranged from 60ºC to -70ºC along the convective line, indicating that parcels were reaching the altitudes indicated by the KOUN sounding. CAPE was 1623 J kg -1 with an LI of -6ºC. These observations indicate the presence of instability and the likelihood of deep storm updrafts in the preline environment. Strong upward vertical motion was likely present in the mixed-phase region of the convective line s updrafts, indicating a high chance for CG lightning consistent with NLDN observations. In summary, the convective line was in a region of moderate instability at the time of initiation. In this environment, maintenance of the convective line was not difficult. Deep, strong updrafts through the depth of the troposphere, evidenced by the degree of instability, were supportive of high lightning frequency. b. No CG Lightning Phase Between 00 and 12 UTC 10 November 1998, the cyclone moved from central Kansas to north-central Iowa. At 12 UTC 10 November, a 500-mb closed low was located over western Iowa, northeast Nebraska, and southeast South Dakota (Fig. 2b). Strong diffluence aloft was noted downstream of the low, and a 45 m s -1 jetstreak had rounded the base of the trough and was moving across Missouri, western Illinois, and entering southwest Wisconsin (Fig. 2b). A 971-mb surface low was located in northcentral Iowa (Fig. 3b). The convective line was located from central Illinois south 4

through eastern Arkansas and into Louisiana at 12 UTC (Fig. 5a). Around 12 UTC, CG lightning rates in the northern portion of the convective line decreased to near zero (Fig. 5b), marking a dramatic shift in the convective line s evolution. Moving eastward, the convective line encountered an increasingly hostile environment for CG lightning production. Although well ahead of the line, the 12 UTC 10 November ILN sounding (Wilmington, Ohio) was the best available sounding to represent the preline environment (Fig. 5d). This sounding had an LI of 2ºC and CAPE of 180 J kg 1, with all the CAPE located at temperatures warmer than 15ûC. Thus, vertical motions within the mixed-phase region of the cloud sufficient to separate charge, ultimately leading to CG lightning, were less likely to occur. Despite its lack of CG lightning, the convection maintained itself and produced damaging winds. A few speculations are presented which may have contributed to the maintenance of the convective line. Inflow of moist air to the east was likely important to the line s maintenance. RUC-derived soundings were examined to evaluate the moisture profile ahead of the convective line. The low levels moistened by 09 UTC, and by 18 UTC RUC-derived soundings indicate a moist adiabatic, nearly saturated atmosphere up to the tropopause. The 21 UTC KCAK sounding (Akron, Ohio) was chosen as a derived sounding representative of the preline environment (Fig. 6). Above about 820 mb, the preline environment was saturated and nearly moist adiabatic. Parcels displaced upward in this environment would experience little resistance to continued vertical motion. Given the strong ongoing convective line and associated frontal circulation, this upward displacement would have easily occurred. 5

Around 12 UTC 10 November as the convective line was moving into Indiana, widespread damaging surface winds were reported despite the lack of CG lightning (Fig. 1). Because of the strong surface cyclone, sustained surface winds of 15.4 to 20.6 m s -1 (30 to 40 knots) were occurring in a large area ahead of and behind the convective line (Fig. 3b). Given the already strong winds, not much would have been required to push convective winds past severe criteria on this day, with high momentum air from aloft likely responsible for the production of damaging surface winds. Cross sections including vertical velocity (ω) from RUC model output support descent of high momentum air at the time widespread damaging winds were occurring in the absence of lightning (Fig. 5c). A broad area of sinking motion reached the surface immediately behind the convective line. Likely contributing to this descent include synoptic-scale sinking behind the cyclone fostered by strong cold advection, mesoscale descent associated with the downward branch of the frontal circulation, and storm-scale descent within individual convective elements. In addition, the moist postline environment promoted moist adiabatic descent. Such moist-adiabatic descent would have been important in two respects. First, conditional instability ( θ es / z < 0) was present behind the line, so moist descent would have been unstable. Second, moist adiabatic conditions reduced the horizontal scale and increased the magnitude of descent immediately behind the convective line (Fig. 5c). Evidence for a moist adiabatic environment behind the convective line includes moist surface air (Fig. 2b) and the development of a parallel stratiform precipitation region (defined by Parker 2000) around the convective line. 6

Vertical wind profiles behind the convective line indicate that not much descent would have been required to bring down air of sufficient momentum to exceed severe criteria. Postline 12 UTC 10 November observed soundings were examined for the lowest level at which 25.7 m s -1 (50 knot) flow occurred. As damaging winds began to reach the surface, 25.7 m s -1 winds could be found at 1030 m AGL (830 mb--davenport, Iowa), 800 m AGL (870 mb--springfield, Missouri), and 735 m AGL (905 mb--little Rock, Arkansas). The low altitude at which 25.7 m s -1 wind was found suggests that descent of sufficient momentum to produce severe wind gusts could have occurred easily. c. Dissipation Phase Between 12 UTC 10 November and 00 UTC 11 November, widespread damaging wind occurred with the convective line across Indiana and Ohio. At 00 UTC 11 November, a broad 500-mb trough was centered over the western Great Lakes, with a closed low centered over western Lake Superior and a large area of 50-70 m s -1 flow within the trough base (Fig. 2c). The occluding surface low had moved to the Canadian border, with a tight pressure gradient and resultant strong winds across the north-central United States (Fig. 3c). By this time, the convective line had dissipated into a rainband extending from southeast Ontario to northern Georgia (Fig. 7a), and was no longer producing damaging wind reports or lightning (Fig. 7b). Soundings taken at 00 UTC 11 November were unfavorable for CG lightning. The soundings from KBUF (Buffalo, New York) and KPIT (Pittsburgh, Pennsylvania Fig. 7d) at this time show zero CAPE and LIs greater than zero. The 10ûC isotherm in each sounding is near 500 mb. With the lack of instability above the 10ûC isotherm, strong updrafts were unlikely in the mixed-phase region. Enough charge separation 7

likely did not occur for the production of CG lightning, consistent with NLDN observations. As speculated above, the nearly moist adiabatic atmosphere ahead of the convective line was likely necessary for its maintenance. Comparing RUC-derived 00 UTC 11 November soundings for KPIT and KBUF with earlier RUC-derived soundings, the preline lower atmosphere was further from saturation at 00 UTC 11 November than at 12 UTC. In the absence of CAPE, deep convection would have been very difficult with a non-moist adiabatic preline environment. As the convective line weakened, its associated frontal circulation also diminished, as shown in RUC model output (Fig. 7c). A weakening in the downward branch of this circulation would have decreased descent of high momentum air, reducing the potential for damaging surface winds. 3. 9-10 March 2002 On 9-10 March 2002, a 500-mb trough was located over the north-central United States, with a deepening surface cyclone moving from the central Plains to the northern Great Lakes. A strong baroclinic zone associated with this low served as a focus for the development of a strongly forced, low-instability convective line, which produced widespread severe wind reports from Kansas and Oklahoma to Iowa (Fig. 8). This line weakened substantially, with almost no severe reports across Illinois and Indiana, then redeveloped in the stable environment to the east and produced widespread damaging wind in Ohio, West Virginia, and western Pennsylvania (Fig. 8). CG lightning 8

production was examined in this case, and the similarities to the 9-11 November 1998 case are discussed. Conditions for the production of CG lightning changed dramatically over 9-10 March 2002. As with 9-11 November 1998, soundings were analyzed to ascertain thermodynamic preline characteristics. The 00 UTC 9 March 2002 TOP sounding (Topeka, Kansas), just east of initiation, showed 793 J kg -1 of CAPE and an LI of 4.3ºC (Fig. 9a). Nearly all CAPE was located between the 10ºC and 40ºC isotherms, indicating the likelihood of strong convective updrafts in the mixed-phase region of the convective line. NLDN data from the early period of the line s evolution shows a high frequency of detected CG lightning (Fig. 10a). CG lightning with the convective line was no longer detected by the NLDN as the line moved into central Indiana around 15 UTC (Fig. 10b). Preline 12 UTC 9 March soundings show a substantial change in thermodynamic parameters, which explains the lack of detected CG lightning. The KILX (Lincoln, Illinois) sounding (Fig 9b) showed CAPE of 1 J kg -1 and an LI of +3.3ºC, and the BNA sounding showed no CAPE with an LI of +4.6ºC. No instability was present in the mixed-phase region of the convective line, not allowing sufficient charge separation for CG lightning. This is consistent with NLDN observations of no detected CG lightning. Around 21 UTC 9 March, the convective line became very intense and produced widespread wind damage across central and eastern Ohio (Fig. 8), yet almost no CG lightning was detected by the NLDN during this time (Fig. 10c). Around 02 UTC 10 March, the NLDN again began detecting high frequencies of CG lightning with the convective line (Fig. 10d). Thermodynamic changes in the preline 9

environment by 00 UTC 10 March began to favor renewed CG lightning production. The KIAD sounding (Sterling, Virginia) was representative of the preline environment (Fig. 9d). It showed CAPE of 465 J kg -1 and an LI of 2ºC. CAPE was present up to the 30ºC isotherm, indicating the potential for well-developed updrafts in the mixed-phase region of the convective line once it moved into the higher-cape area. Charge separation and CG lightning should have been able to occur, and NLDN data shows a high frequency of CG lightning (Fig. 10d). Three similarities were found between the 9-11 November 1998 and 9-10 March 2002 cases regarding the maintenance of the strongly forced, low-instability convective line and the production of damaging winds. First, preline soundings from KILX (12 UTC 9 March Fig. 9b) and KIAD (00 UTC 10 March Fig. 9c) show a nearly moist adiabatic preline atmosphere, with saturation up to 500 mb (KILX) and 750 mb (KIAD). Second, these soundings showed 30 m s -1 of flow at 730 m AGL (ILX) and 900 m AGL (IAD), indicating that high-momentum air could have easily descended to the surface. An increase in 850-mb flow of 10 m s -1 (20 knots) occurred as the convective line was beginning to produce more widespread damaging winds in Ohio around 21 UTC 9 March. Third, the RUC model output showed a frontal circulation along the convective line, the downward branch of which seems to have transported high-momentum air from aloft. 10

4. Conclusions Two strongly forced, low-instability convective lines (9-11 November 1998 and 9-10 March 2002) are examined to understand the factors that control the production of CG lightning in these systems. When CG lightning is frequent, CAPE implies vertical motions of several m s -1 in the mixed-phase region of the cloud, between 10ºC and 40ºC, where the charge separation process is thought to occur (MacGorman and Rust 1998, 218-220). When CG lightning is absent, little or no instability is found in the cloud s mixed-phase region. Thus, the vertical distribution of CAPE in the mixed-phase region, rather than the mere presence of CAPE in a sounding, is important for determining the occurrence of CG lightning from synoptic data. Synoptic flow was very strong in both cases, so not much was required for severe wind to reach the surface. Descent of momentum from aloft is thought responsible for the damaging surface winds in both events. This descent originated on the synoptic scale behind the associated cyclone, on the mesoscale from the downward branch of the associated frontal circulation, and from storm-scale downdrafts. Consequently, even environments with low or zero instability, if strongly forced, are capable of producing severe weather, even in the absence of CG lightning. 11

Acknowledgments. I would like to thank Phillip Bothwell for making November 1998 and March 2002 gridded lightning data available, Jason Levit for supplying 9-10 March 2002 case study data, and David Bright for insight into how the Storm Prediction Center forecasts lightning. Many thanks to my mentors for providing frequent insight, and to the other REU students for their support. This material is based on work supported by the National Science Foundation under Grant No. 0097651. References Connors, J. A., 1999: Convective initiation and frontal structure of a squall line in the central plains on 9-10 November 1998. REU Final Report. MacGorman, D. R., and W. D. Rust, 1998: The Electrical Nature of Storms. Oxford University Press, 422 pp. Parker, M. D., and R. H. Johnson, 2000: Organizational modes of midlatitude mesoscale convective systems. Mon. Wea. Rev., 128, 3413-3436. 12

List of Figures Figure 1: Storm reports for the 9-11 November 1998 severe weather event. Legend: hail reports are circles, wind reports are crosses, and tornado tracks are line segments. Figure 2: 500-mb analysis of isohypses (solid lines every 6 dam), isotherms (dashed lines every 5ºC), and isotachs (shaded for wind 40 m s -1 and 50 m s -1 ); barbs in m s -1 (pennant, full barb, and half barb denote 50, 10, and 5 m s -1, respectively): a) 00 UTC 10 November; b) 12 UTC 10 November; c) 00 UTC 11 November. Figure 3: Sea level pressure (solid lines every 4 mb), temperature (solid lines every 5ºC), dewpoint (solid lines every 5ºC), and horizontal wind (pennant, full barb, and half barb denote 25, 5, and 2.5 m s -1, respectively) for the central United States, along with the position of the convective line (dashed and dotted line) : a) 00 UTC 10 November; b) 12 UTC 10 November; c) 00 UTC 11 November. Figure 4: 4-panel of fields for 0000 UTC 10 November 1998: a) central US radar image; b) NLDN-detected CG strikes for the central United States between 00 and 03 UTC 10 November; c) RUC-derived cross section through convective line, showing omega (shaded, contour interval as shown), potential temperature (solid lines every 1 K), and wind barbs (pennant, full barb, and half barb denote 25, 5, and 2.5 m s -1, respectively); d) representative preline observed sounding from KOUN (Norman, Oklahoma). Figure 5: 4-panel of fields for 1200 UTC 10 November 1998: a) central US radar image; b) NLDN-detected CG strikes for the central United States between 12 and 15 UTC 10 November; c) RUC-derived cross section through convective line, showing omega (shaded, contour interval as shown), potential temperature (solid 13

lines every 1 K), and wind barbs (pennant, full barb, and half barb denote 25, 5, and 2.5 knots, respectively); d) representative preline observed sounding from KBNA (Nashville, Tennessee). Figure 6: Representative RUC-derived preline sounding, 21 UTC KCAK (Akron, Ohio). Figure 7: 4-panel of fields for 0000 UTC 11 November 1998: a) central US radar image; b) NLDN-detected CG strikes for the central United States between 00 and 03 UTC 11 November; c) RUC-derived cross section through convective line, showing omega (shaded, contour interval as shown), potential temperature (solid lines every 1 K), and wind barbs (pennant, full barb, and half barb denote 25, 5, and 2.5 m s -1, respectively); d) representative preline observed sounding from KPIT (Pittsburgh, Pennsylvania). Figure 8: Storm reports for the 9-10 March 2002 severe weather event. Legend: hail reports are circles, wind reports are crosses. Figure 9: Representative preline observed soundings for the 9-10 March case; these were obtained from the University of Wyoming s website (http://weather.uwyo.edu/upperair/soundings.html): a) 00 UTC 9 March KTOP (Topeka, Kansas) sounding; b) 12 UTC 9 March KILX (Lincoln, Illinois) sounding; c) 00 UTC 10 March KIAD (Sterling, Virginia) sounding. Figure 10: NLDN-detected CG strikes for the central United States: a) 00 to 03 UTC 9 March 2002; b) 12 to 15 UTC 9 March 2002; c) 21 UTC 9 March to 00 UTC 10 March 2002; d) 03 to 06 UTC 10 March 2002. 14