A new FMECA model for reliability computations in electrical distribution systems

Similar documents
BVES Annual Reliability Public Presentation 2016 Performance

Research Article RELIABILITY ASSESSMENT OF RADIAL NETWORKS VIA MODIFIED RBD ANALYTICAL TECHNIQUE

GIS Solution For Electric Utilities With Integration With Distribution Management System

DISTRIBUTION SYSTEM ELECTRIC INFRASTRUCTURE RELIABILITY PERFORMANCE INDICATORS

Debbie Lee, Communications and Public Affairs Officer. Update on Southern California Edison s Capital Improvement Projects

ELECTRIC SYSTEM RELIABILITY ANNUAL REPORT

Network Quality and Reliability of Supply

A Markov model for estimating the remaining life of electrical insulation in distribution transformer

Reliable Computing I

Mitigation of Distributed Generation Impact on Protective Devices in a Distribution Network by Superconducting Fault Current Limiter *

Reven ue Req u i remen t Ap pl icat ion 2004/05 and 2005/06. BC hydro m W. Volume 2. Appendix L. System Performance Indicators

Network Quality and Reliability of Supply Code

DISTRIBUTION SYSTEM OPTIMISATION

Wenhui Hou* Department of Mechanical Engineering, Tangshan Polytechnic College, Tangshan , China *Corresponding author(

Minnesota Public Utilities Commission Staff Briefing Papers

Quantitative evaluation of Dependability

Chapter 6. a. Open Circuit. Only if both resistors fail open-circuit, i.e. they are in parallel.

SHORT CIRCUITS IN 3kV DC SYSTEM: STRESSES ON VEHICLES AND INFRASTRUCTURE ELECTRIC EQUIPMENT

Chapter 2. Planning Criteria. Turaj Amraee. Fall 2012 K.N.Toosi University of Technology

CAPACITOR PLACEMENT IN UNBALANCED POWER SYSTEMS

OPALCO Outage Analysis. December 2017 Board Meeting

XLVI Pesquisa Operacional na Gestão da Segurança Pública

12 - The Tie Set Method

Section 5. TADS Data Reporting Instruction Manual DRAFT Section 5 and Associated Appendices With Proposed Event Type Numbers

EN50160 Power Analysis Report PowerCET Corporation Santa Clara, CA

PUB NLH 185 Island Interconnected System Supply Issues and Power Outages Page 1 of 9

Quantitative evaluation of Dependability

2013 December Ice Storm

Enterprise GIS to Support ADMS ESRI GeoConx EGUG 2016 Parag Parikh

Safety and Reliability of Embedded Systems

Evaluation of the risk of failure due to switching overvoltages of a phase to phase insulation

Reliability Assessment of Radial distribution system incorporating weather effects

Reducing Wildfire Risk through the Use of Advanced Electrical Waveform Monitoring and Analytics

9. Reliability theory

Periodic Inspection and Testing of Electrical Installations Sample Test ( ) Version 1.3 July 2018

Optimal Capacitor placement in Distribution Systems with Distributed Generators for Voltage Profile improvement by Particle Swarm Optimization

PTS Volt DC surface mount resettable PTC devices. Technical Data Applications. Agency information.

RELIABILITY is the measure that describes the ability of a

Fault Location in Distribution Feeders with Distributed Generation using Positive Sequence Apparent Impedance

Quantitative Reliability Analysis

THE DIMENSIONING OF ELECTRICAL CONDUCTORS FOR USE IN "PANEL BOARDS" ADDRESSED TO HAZARDOUS AREAS - PART THREE

Review of. Florida s Investor-Owned Electric Utilities Service Reliability reports. State of Florida

Maintenance free operating period an alternative measure to MTBF and failure rate for specifying reliability?

Harmonic Modeling of Networks

Causal & Frequency Analysis

P.O BOX 429, NUKU ALOFA, Tel: (676) Fax: (676)

1SDC007004D0201. Discrimination tables

Practical Aspects of MIL-DTL Appendix A Initiator Testing. Barry Neyer NDIA Fuze Conference May 14 th 2008

STATE ESTIMATION IN DISTRIBUTION SYSTEMS

High Voltage Capacitors Designed to Avoid Catastrophic Failure Modes

Reliability of Spacecraft. Power Systems

10.Reliability evaluation of complex distribution systems

Role of Synchronized Measurements In Operation of Smart Grids

Field data reliability analysis of highly reliable item

KINGS COLLEGE OF ENGINEERING Punalkulam

Fault Calculation Methods

Effects of Capacitor Bank Installation in a Medium Voltage (MV) Substation

Reliability Analysis of Electronic Systems using Markov Models

Selecting the current rating for equipment

of an algorithm for automated cause-consequence diagram construction.

Power System Research Group Electrical Engineering Dept., University of Saskatchewan Saskatoon, Canada

4-bit magnitude comparator

CHAPTER 10 RELIABILITY

SYNCHRONOUS GENERATOR s ROTOR INVESTIGATION OF A HYBRID POWER SYSTEM INCLUDING A.G.

Circuit Reliability Review

Safety analysis and standards Analyse de sécurité et normes Sicherheitsanalyse und Normen

Hydra Fault Current Limiting HTS Cable to be Installed in the Consolidated Edison Grid

NORDIC AND BALTIC GRID DISTURBANCE STATISTICS 2015

B.H. Far

Norm Hann Performance Manager, Performance Management Department Hydro One Networks Inc.

Congestion Alleviation using Reactive Power Compensation in Radial Distribution Systems

Reliability Based Vegetation Management Through Intelligent System Monitoring

Assessing system reliability through binary decision diagrams using bayesian techniques.

Reverse Engineering Project EEL 4906 Engineering Design/Professionalism

Review of. Florida s Investor-Owned Electric Utilities Service Reliability reports. State of Florida

Time-varying failure rate for system reliability analysis in large-scale railway risk assessment simulation

ESTIMATION OF CAPACITOR BANK SWITCHING OVERVOLTAGES USING ARTIFICIAL NEURAL NETWORK

Reduction of Detected Acceptable Faults for Yield Improvement via Error-Tolerance

8-BIT SYNCHRONOUS BINARY UP COUNTER

TRANSIENTS POWER SYSTEM. Theory and Applications TERUO OHNO AKIH1RO AMETANI NAOTO NAGAOKA YOSHIHIRO BABA. CRC Press. Taylor & Francis Croup

TL 9000 Quality Management System. Measurements Handbook. SQ Examples

ECE 476. Exam #2. Tuesday, November 15, Minutes

Computer Science, Informatik 4 Communication and Distributed Systems. Simulation. Discrete-Event System Simulation. Dr.

Modeling of Transmission Line and Substation for Insulation Coordination Studies

Capacitor Application Issues

Fundamentals of Polymeric PTC 0vercurrent Circuit Protection

Review of Florida s Investor-Owned Electric Utilities Service Reliability Reports. September

Reliability Engineering I

SRP Voltage Sag Index Methodology Experience and FAQs

SIDEWINDER DRILLING RIG 102 HOUSTON, TEXAS

Development of Multi-Unit Dependency Evaluation Model Using Markov Process and Monte Carlo Method

HEF4028B. 1. General description. 2. Features. 3. Applications. 4. Ordering information. BCD to decimal decoder

Detection of Broken Conductor with Ground Contact Faults in Medium Voltage Power Networks

74HC153-Q100; 74HCT153-Q100

NEW RECLOSER CHARACTERISTIC TO IMPROVE FUSE SAVING IN DISTRIBUTION NETWORKS WITH DISTRIBUTED GENERATION

Reliability Indices Measurement Reliability Indices Measurement for three 11 kv and 66 kv substations in Brunei Darussalam (PWR 01)

The Applications of Inductive Method in the Construction of Fault Trees MENG Qinghe 1,a, SUN Qin 2,b

Reliability of Bulk Power Systems (cont d)

Chapter 5. System Reliability and Reliability Prediction.

74HC4050-Q100. Hex non-inverting HIGH-to-LOW level shifter

Transcription:

Proceedings of the 6th WSEAS/IASME Int. Conf. on Electric Power Systems, High Voltages, Electric Machines, Tenerife, Spain, December 6-8, 2006 A new FMECA model for reliability computations in electrical distribution systems FRANCESCO MUZI Department of Electrical Engineering and Computer Science University of L Aquila Monteluco di Roio, L Aquila 6700 ITALY Abstract: Electrical distribution systems usually have complex configurations with a number of missions corresponding to the many different requested functions. The levels of reliability and availability of each function depend on both the length of each reliability chain and on the devices involved in each path starting from the power node and terminating at an end-user. This paper describes a new procedure for an FMECA (Failure Mode Effects and Criticality Analysis), since the classical FMECA procedure usually applied to analyze electronics and systems is inadequate to analyze electrical power systems. Actually, the classical procedure using the so-called bottom-up approach implies that components (the sons ) are responsible for s in a system (the father ). In electrical radial systems where primary power are placed upstream and the end-users are downstream, the s of the upstream components (fathers) affect the final (sons). This implies a reversal of the hierarchy reliability logic. In addition, there is a further difference because in electronics and systems a great number of causes can provoke system (end-effect) while in electrical systems very few causes (connected to primary power ) can involve very numerous end-effects on a myriad of end-user. In order to overcome these difficulties, the FMECA method here described proceeds by subdividing a system into levels, then examines the causes and the linked effects level by level, starting from the end-users (top-events), and going upwards to the power- nodes (first-causes). After a general overview of the difficulties arising when the classical FMECA is applied to electrical systems, the new method is thoroughly described and discussed. Key-Words: Reliability and quality in design, Electrical distribution systems, FMECA (Failure Mode Effects and Criticality Analysis). Introduction In electrical distribution systems a reliability analysis mainly deals with equipment s and end-user interruptions. Under normal operating conditions all apparatuses (except stand-bys) are energized and all users are supplied. Both scheduled and non-scheduled events [2] can cause damages and s to apparatuses and consequently energy interruptions. Though not usually directly involved in system problems, users are however affected by energy interruptions. If the is restored within a few minutes, the interruption is called temporary otherwise it is named prolonged. The time duration of a temporary interruption can vary from to 5 minutes depending on a customer s energy supplier. The reliability of electrical distribution systems is defined by indexes drawn from sample statistics of loads, components and users. These indexes usually take the average values of certain reliability features in a whole system, an operating region, a substation, a feeder, etc. In the last decade a great number of these indexes have been defined, the most important of which are the following: - The SAIFI (System Average Interruption Frequency Index), which represents the average frequency of sustained interruptions

Proceedings of the 6th WSEAS/IASME Int. Conf. on Electric Power Systems, High Voltages, Electric Machines, Tenerife, Spain, December 6-8, 2006 2 per customer occurring during the analysis period. - The SAIDI (System Average Interruption Duration Index), which represents the average interruption duration per customers served during a specified time period. - The CAIDI (Customer Average Interruption Duration Index), which represents the average length of an interruption, weighted by the number of customers affected, per customers interrupted during a specific time period. - The ASAI (Average Service Availability Index), which represents the fraction of time (often as a percentage) when a customer has received power during a pre-defined period of time. - The ASIFI (Average System Interruptions Frequency Index), which represents the ratio between the interrupted kva and total kva served. - The ASIDI (Average System Interruption Duration Index, which represents the ratio between the hours of interrupted kva and total kva served. In practical cases, a reliability analysis is usually completed by means of an additional procedure known as FMECA (Failure Mode Effects and Criticality Analysis). This procedure examines each possible mode of every component in a system as well as its causes, evaluating how each affects the correct operating conditions of the system [4], [5], [6]. 2 The proposed FMECA procedure The FMECA is a well-established procedure traditionally used to analyze and electronic systems with a bottom-up approach, which means starting from the modes and causes in the single LRUs (Line Replaceable Units) and investigating the effects on the final system and the linked criticalities. Usually the LRUs are named sons and the final system father. Actually, while in traditional FMECA applications the LRUs (sons) contribute to a system s (father) performances, in radial electrical systems the hierarchy structure is very different. As a matter of fact, since energy proceeds from upstream to downstream, the s affecting upstream components (generators, circuit-breaker, bus-burs, etc.) cause effects to downstream. Therefore causes depend on the upstream components while end effects are localized at the terminations of the final circuit breakers [7]. This leads to a remarkable reversal of hierarchy logic since upstream elements (fathers) are responsible for the causes while downstream components (sons) are affected by the associated consequences. A further difference to be mentioned is that while in traditional FMECA applications the hierarchy structure is pyramidal, i.e. many dozens (or hundreds) of causes produce very few top events, in electrical radial systems this pyramid is upsidedown since very few causes (linked to the main power nodes) produce a great number of final effects usually involving many end-users. A traditional FMECA procedure applied to electrical radial systems may be carried out starting from downstream components (sons) to ascend the hierarchy scale towards the main power node (or nodes). In this case the bottom-up approach is applied but following causes instead of effects. The inconvenience may be overcome approaching the problem with the FTA (Fault Tree Analysis), a traditional procedure used to identify the causes that lead to certain system faults [], [3]. The FTA is a topdown procedure with two main advantages: - It allows the prompt use of both the AND/OR operators. - It allows the placement of identical system items at different points in the tree representation. Unfortunately, in electrical radial systems an FTA approach involves a number of limitations: - it does not allow to take different modes into consideration directly; - partial effects cannon be considered; - it is not possible to declare possible solutions to presumed effects; - it does not allow to take into consideration the conditional probabilities of a faulted system once a component is assumed to be faulted.

Proceedings of the 6th WSEAS/IASME Int. Conf. on Electric Power Systems, High Voltages, Electric Machines, Tenerife, Spain, December 6-8, 2006 3 For all these reasons, a new tabular procedure was introduced with the following advantages: - a clear, functional description of the system; - an effective representation of redundancies; - a modular configuration joining FMECA and FTA capabilities; - a representation based on a reversed pyramidal structure. The proposed method requires a preliminary subdivision of the system into different levels and then, starting from end-users (Top-Events), analyzes both internal and external causes of s as well as their effects at each system level, going upwards to the main power- nodes (Primary-Causes). 3 Application of the method To better understand the proposed method, in this section an effective application is described and discussed. The application regards the radial electrical system shown in Fig.. The application of the proposed method, which assumes the system mission to be the of an end-user L, is concisely resumed in Table. The meaning of the symbols adopted in Table is explained in the following: ) Level It consists of a bus-bar with the connected circuit-breakers and the switchdisconnector placed upstream the same bus-bar. The 0 level corresponds to the final-user (Top-Event), while the last level corresponds to system power block. The levels listed in cascade on the first column of the table are placed functionally in series connection. 2) Function - It describes the function performed by the level. 3) Level mode It describes in which way the level or the LRU can fail. The mode can be of two kinds: either internal to the considered level, or external, which means it depends on causes coming from the level above. G2 LEVEL 2 Q2 C Bus-bar A Bus-bar B LEVEL I I2 L L2 LEVEL 0 Fig.. Diagram of the examined radial electrical system.

B Proceedings of the 6th WSEAS/IASME Int. Conf. on Electric Power Systems, High Voltages, Electric Machines, Tenerife, Spain, December 6-8, 2006 4 4) Failure causes of the level - It describes how internal components of the level contribute to the of their own level. 5) Failure local causes of the level (internal) It describes the modes of the internal components that contribute to the of their own level. 6) Symbol of the component Symbol of the component undergoing. Under a reliability point of view the elements located inside a level are connected serially. If redundancies are present, the different groups of the serially connected components are separated by a symbol &. 7) Component rate In this column the rates of the components in column 4 are reported. 8) α It is the rate ratio, which is similar to the ratio used in traditional FMECA procedures. It is important to note that for each LRU the following condition must be verified: i α i =. 9) Level rate It is the summation of the rates of the elements composing the level. The components are those reported in column 4. 0) Causes from the above level (external) These are the causes due to the components of the level above. ) Equivalent rate It is the total rate due to all causes, both internal and external. In the case of internal causes this rate corresponds to the rate of the LRU examined while for external causes it is the summation of the rates of the LRUs encountered in the series connection. 2) Local effects It describes the local effects of the. 3) β - It is the conditional probability ratio, i.e. the probability that both internal and external causes can produce the end-effect. For elements connected in series, this coefficient is equal to. In fact, as shown in Fig. 2, in this case just one element is able to cause a system s (β A = β B = β B = B ). A B C Fig. 2. Elements connected in series. For elements connected in parallel, the β coefficient is lower than because, as shown in Fig. 3, redundancies are present. A B Fig. 3. Elements connected in parallel. In this case the following conditions can be assumed: A,B S; C,D S2 and S,S2 S Applying the Bayes theorem, it can be written: A = 2 MTTR A, that corresponds to the probability that S2 fails when A is subject to S β B = βs2 MTTR BB, that corresponds to the probability that S2 fails when B is subject to C = MTTR C, that corresponds to the probability that S fail when C is subject to a repair process. D = MTTR D, that corresponds to the probability that S fails when D is subject to If the system is made of two stand-by elements, where A is the default element and B the element activated only when the default element fails: A = β B B MTTRA, that corresponds to the probability that B fails when A is subject to a repair process. S β B B =, because a in B causes the whole system to stop. 4) Criticality It is the criticality computed as α β λ t where t is the mission time. 5) Severity It is the severity defined by the following four levels: I= catastrophic; II= critical; III= important; IV= minor. C D Table Demo application of the proposed FMECA procedure. Level Function 2 Level mode 3 Failure causes at level 4 Failure local causes (internal) 5 Symbol of the component 6 rate 7 α 8 Level rate 9 Causes from the above level (external) 0 Component Equivalent rate Local effects 2 β 3 Criticality Severity 4 5

Proceedings of the 6th WSEAS/IASME Int. Conf. on Electric Power Systems, High Voltages, Electric Machines, Tenerife, Spain, December 6-8, 2006 5 0 L L Voltage interruption absence Failure on L (Top-Event) L λi λi I missed λi α closing I incorrect I L does not opening λi α2 Endusers energy λi+λa A bus-bar A λa L does not receives - - - - - - energy missed λq α 2 Power Absence of the D default power & Absence of the R reserve power closing incorrect opening generator & Q2 incorrect opening Q2 missed closing C disconnector opened B bus-bar G2 generator λq α2 λg Q2 λq2 α λq+ λg Level does not feed energy Level 2 does not feed energy Q2 λq2 α2 λq2+ C λc λc+λb+ λg2 - B λb G2 λg2 λi+λlev +λeqd&r λlev+ λeqd&r λeqd&r Mission missed II Unfed Endusers Unfed all downstream users II λr mttr λr mttr IV II 4 Conclusions Electrical radial systems are characterized by a peculiar hierarchy structure since power comes from upstream to downstream, which makes upstream elements responsible for the causes with the end-effects occurring at the terminations of the breakers feeding end-users. This leads to a reversed hierarchy logic since the structures placed upstream (fathers) generate the causes and the structures downstream (sons) are affected by the consequences. To solve this problem, a new FMECA procedure was proposed. After subdividing a system into levels, the new procedure employs a tabular representation to study the system, taking also redundancies into account. Starting from the endusers, internal and external causes and their consequent effects on the final system are analyzed level by level. References [] H. Kunamoto, E. J. Henley, Probabilistic risk assessment and management for engineers and scientists, IEEE - New York, 996. [2] E. Cinieri, F. Muzi - Lightning Induced Overvoltages. Improvement in Quality of Service in MV Distribution Lines by Addition of Shield Wires. IEEE Transactions on Power Delivery - Vol. n., N., January 996. [3] IEEE Recommended practice for design of reliable industrial and commercial power systems, IEEE - New York, 997. [4] F. Muzi Criticality analysis of electric substations ing high-speed railway systems. Fifth ISSAT International Conference on Reliability and Quality in Design - August -3, 999, Las Vegas, Nevada, USA. [5] Military Handbook for the reliability prediction of the electronic equipment, MIL- HDBK-27. [6] Military Standard Procedures for Performing a Failure Mode, Effects and Criticality Analysis, MIL-STD-629. [7] F. Muzi, C. Buccione, S. Mautone A new architecture for systems ing essential loads in the Italian High-Speed Railway (HSR). WSEAS Transactions on Circuits and Systems, Issue 8, Volume 5, August 2006.