Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm accuracy according to IEC 600: standard: 0. % FSO option: 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 0 bar Contacts, or independent PNP contacts, freely configurable Analogue output wire:... 0 ma wire: 0 ma / 0 0 V others on request Special characteristics indication of measured values on a digit LED display rotable and configurable display module configurable contacts (switch on/switch off points, hysteresis/window mode, switch on/switch off delay) Optional versions The electronic pressure switch is the successful combination of intelligent pressure switch digital display and is suitable for the usage with viscous and pasty media. As standard the offers a PNP contact and a rotatable display module with digit LED display. Optional versions like e.g. an intrinsically safe version, max. contacts and an analogue output complete the profile. Preferred areas of use are Food industry Pharmacy ISversion Ex ia = intrinsically safe for gases specific versions
Input pressure range Nominal pressure (P N) gauge / abs.... 0 0.0 0.6 0. 0.0 0.60.6. 6 0 6 0 Overpressure 0. 0 0 0 0 0 80 80 0 Burst pressure...... 0 0 0 0 0 Vacuum resistance P N bar: unlimited vacuum resistance P N < bar: on request consider the pressure resistance of fitting and clamps Contact PNP contact Options independent PNP contacts independent PNP contacts (possible with Mx, 8pin for... 0 ma/wire; 0... 0 V/wire on request) Max. switching current... 0 ma / and wire: contact rating ma, shortcircuit resistant; V Switch = V S V 0... 0 V / wire: contact rating 00 ma, shortcircuit resistant Accuracy of contacts standard: P N < 0. bar: ± 0. % FSO P N 0. bar: ± 0. % FSO option: P N 0. bar: ± 0. % FSO Repeatability ± 0. % FSO Switching frequency max. 0 Hz Switching cycles > 00 x 0 6 Delay time 0... 00 sec max. contact for wire current signal with plug ISO 00 as well as wire current signal with ISprotection no contact possible with wire in combination with plug ISO 00 accuracy according to IEC 600 limit point adjustment (nonlinearity, hysteresis, repeatability) Analogue output (optionally) / Supply wire current signal... 0 ma / V S =... 6 V DC permissible load: R max = [(V S V S min) / 0.0 A] Ω response time: < 0 msec wire current signal with ISprotection... 0 ma / V S =... 8 V DC permissible load: R max = [(V S V S min) / 0.0 A] Ω response time: < 0 msec wire current signal... 0 ma / V S = 9... 0 V DC adjustable (turndown of span :) permissible load: R max = 00 Ω response time: < 0. sec wire voltage signal 0 0 V / V S =... 6 V DC permissible load: R min = 0 kω response time: < 0 msec Without analogue output V S =... 6 V DC Accuracy standard: P N < 0. bar: ± 0. % FSO P N 0. bar: ± 0. % FSO option: P N 0. bar: ± 0. % FSO with turndown of span the analogue signal is adjusted automatically to the new measuring range Thermal errors (Offset and Span) / Permissible temperatures Nominal pressure P N 0 < 0.0 0.0 Tolerance band [% FSO] ± 0. ±. ± 0. in compensated range [ C] 0... 8 0... 0 0... 8 Permissible temperatures 6 medium: 0... C for filling fluid silicon oil 0... C for filling fluid food compatible oil electronics / environment: 0... 8 C storage: 0... 00 C Permissible temperature medium filling fluid silicon oil overpressure: 0 00 C vacuum: 0... 0 C for cooling element 00 C filling fluid food compatible oil overpressure: 0... 0 C vacuum: 0... 0 C an optional cooling element can influence thermal effects for offset and span depending on installation position and filling conditions. 6 max. temperature of the medium for nominal pressure gauge > 0 bar: 0 C for 60 minutes with a max. environmental temperature of 0 C also for P abs < bar Electrical protection Shortcircuit protection permanent Reverse polarity protection no damage, but also no function Electromagnetic compatibility emission and immunity according to EN 66 Mechanical stability Vibration g RMS (... 000 Hz) according to DIN EN 600686 Shock 00 g / msec according to DIN EN 60068 Filling fluids silicon oil Options food compatible oil (with FDA approval) (Mobil SHC Cibus ; Category Code: H; NSF Registration No.: 00) others on request Materials Pressure port / Housing stainless steel.0 (6 L) others on request Display housing PA 6.6, Polycarbonate Seals (media wetted) standard: FKM (recommended for medium temperatures 00 C) option: FFKM (recommended for medium temperatures > 00 C) clamp and dairy pipe: without Diaphragm standard: stainless steel. (6 L) option: Hastelloy C6 (.89); Tantalum on request Media wetted parts pressure port, seals, diaphragm pressure and level
Explosion protection (only for 0 ma / wire) Approval AX IBExU06ATEX00 X zone : II G Ex ia IIC T Gb (connector) / II G Ex ia IIB T Gb (cable) Safety technical maximum U values i = 8 V, I i = 9 ma, P i = 660 mw, C 0 nf, L i 0 µh Max. switching current 8 0 ma Permissible temperatures for environment Connecting cables (by factory)... 0 C cable capacitance: signal line/shield also signal line/signal line: 00 pf/m cable inductance: signal line/shield also signal line/signal line: µh/m 8 the real switching current in the application depends on the power supply unit Miscellaneous Display digit, red segmentled display, digit height mm, range of indication 999... +9999; accuracy 0. % ± digit; digital damping 0. 0 sec (programmable); measured value update 0.0 0 sec (programmable) Current consumption wire signal output current: max. ma (without contacts) wire signal output current: approx. ma + signal current wire signal output voltage: approx. ma Ingress protection IP 6 Installation position any (standard calibration in a vertical position with the pressure port connection down; different installation position for P N bar have to be specified in the order) Weight Operational life CEconformity Wiring diagrams wiresystem (current) approx. 60... 0 g > 00 x 0 6 cycles EMC Directive: 00/08/EC wiresystem (current / voltage) p supply + p supply + VS VS supply A supply signal + contact A/V I contact contact I/U contact contact contact Pin configuration Electrical connection Supply + Supply Signal + (only wire) Contact Contact Contact Contact Shield Mx plastic via pressure port Electrical connections (dimensions in mm) Mx metal plug housing/ pressure port Mx plastic (8pin) 6 via pressure port ISO 00 ground contact Binder series pressure port cable colours (DIN 00) wh (white) bn (brown) gn (green) gy (grey) pk (pink) ye/gn (yellow / green) cable outlet PVC Ø =.9mm cable outlet PUR Ø =.mm Mx Mx (8pin) ISO 00 Binder series (polig) cable outlet different cable types and lengths available, permissible temperature depends on kind of cable; standard: m PVC cable (without ventilation tube, permissible temperature:... 0 C)
Mechanical connections (dimensions in mm) G/" flush (PN bar) Option G/" flush G" flush G/" flush with G" flush with radial oring radial oring ( PN bar) G" cone dairy pipe (DIN 8) clamp (DIN 66) cooling element 00 C SIL and SILEx version: total length increases by 6. mm! metric threads and other versions on request dimensions in mm size DN DN 0 DN 0 A B 6 68, C 0 0 P N 0, 0 0, 0 0, dimensions in mm size ¾ DN DN DN 0 A B 0, 0, 6 P N 8 0, 6 6 6 This data sheet contains product specification, properties are not guaranteed. Subject to change without notice. DS00P_E_00
Pressure Input Analogue output gauge absolute 8 8 6 0.0 0 0 0 0.6 6 0 0 0. 0 0 0.0 0 0 0 0.60 6 0 0 0.0 0 0.6 6 0. 0.0 0 0 6.0 6 0 0 0 0 0 6 6 0 0 0 0 0 0 X 0 9 9 9 0 E 0 0 V / wire 0 ma / wire, adjustable Intrinsic safety 0 ma / wire Contact, contact, contacts contacts Accuracy standard for P N > 0, bar 0. % standard for P N 0, bar 0. % option for P N 0, bar 0. % Electrical connection Male plug Mx / plastic version N 0 Male plug Mx (8pin) / plastic version M 0 Male plug Mx / metal version N Male and female plug ISO 00 Male plug Binder series Cable outlet incl. cable 0 0 0 T A 0 9 9 Mechanical connection G/" with flush welded diaphragm (DIN 8) Z 0 0 G/" with flush welded diaphragm (DIN 8) Z 0 G" with flush welded diaphragm (DIN 8) Z G" DIN 8 with rad. oring and flush diaphragm 6 Z G/" DIN 8 with rad. oring and flush diaphragm Z 6 G " cone Clamp DN / " (DIN 66) Clamp DN / /" (DIN 66) Clamp DN 0 / " (DIN 66) K C 6 C 6 C 6 Clamp /" (DIN 66) C 6 9 Dairy pipe DN (DIN 8) Dairy pipe DN 0 (DIN 8) Dairy pipe DN 0 (DIN 8) M M M 6 9 9 Diaphragm Stainless steel. (6L) Tantalum T consult Hastelloy C6 (.89) H Seals for clamp or dairy pipe: without 0 for inch thread: FKM FFKM Filling Fluids Silicon oil food compatible oil Special version with Ex version max. contact is possible with connector ISO 00 and output wire version only max. contact possible; with wire version no contact possible contacts and Mx, 8pin only possible in combination and together with... 0 ma/wire; 0... 0 V/wire on request standard: m PVC cable without ventilation tube (permissible temperature: 0 C), others on request possible only for P N bar 6 possible only for P N bar without 0 ma / wire standard with cooling element up to 00 C Ordering code 0 0 0 0 0 9 9 The cup nut for dairy pipe has to be mounted by production of pressure transmitter. The cup nut has to be ordered as separate position. 0..0 This dokument contains product specification; properties are not guaranteed. Detailed information about options are defined in the datasheet. Subject to change without notice.