How to Use Kinetic Modeling Analysis To Predict Profile Part Failure

Similar documents
DSC AND TG/DTA AS PROBLEM-SOLVING TOOLS: CHARACTERIZATION OF PHARMACEUTICAL COMPOUNDS

TECHNICAL UPDATE. Ricon Resins Peroxide Curing Data and Use as a Reactive Plasticizer in Polyphenylene Ether Based CCL and PWB

Apparent Melting: A New Approach to Detecting Drug-Excipient Incompatibility

High Pressure DSC Differential Scanning Calorimeter

Thermal analysis unlocks the secrets of elastomers

Characterization of Solid State Drugs by Calorimetry

CHEM*3440. Thermal Methods. Thermogravimetry. Instrumental Components. Chemical Instrumentation. Thermal Analysis. Topic 14

Modulated DSC Paper #8 Use Of Quasi-isothermal Mode for Improved Understanding of Structure Change

Thermal Methods of Analysis Theory, General Techniques and Applications. Prof. Tarek A. Fayed

Standard Practice for Heat Aging of Plastics Without Load 1

Complete Materials Deformulation Using TGA-IR

Kinetic evaluation of decabromodiphenil oxide as a ame retardant for unsaturated polyester

INTERNATIONAL STANDARD

VOCs Emissions and Structural Changes of Polypropylene During Multiple Melt Processing

DSC Methods to Quantify Physical Aging and Mobility in Amorphous Systems: Assessing Molecular Mobility

Analyzing & Testing. Comprehensive Material Characterization. Leading Thermal Analysis

Analysing Phenol-Formaldehyde Resin Reaction For Safe Process Scale Up

Thermal methods. P A Sathe Ramnarain Ruia College, Mumbai

Analyzing & Testing. Photocalorimetry Photo-DSC. Method, Technique, Applications. Photo-DSC 204 F1. Leading Thermal Analysis

POLYAMIDE-6,9 WITH CARBAZOLE

Thermogravimetric Analysis Advanced Techniques for Better Materials Characterisation

SILMALAB is a laboratory of analysis for plastics industry that takes advantage of the experience gained by our engineers in 30 years of work and

DSC PT 10. Applications

Title: Bulk Thermal Stability Characterization via the SBAT Apparatus

The Kinetics of B-a and P-a Type Copolybenzoxazine via the Ring Opening Process

ISO INTERNATIONAL STANDARD. Plastics Differential scanning calorimetry (DSC) Part 4: Determination of specific heat capacity

Post-Show. Chemistry. Periodic Table of the Elements. After the Show. Traveling Science Shows

DETERMINATION OF THE DECOMPOSITION PRODUCTS OF CALCIUM OXALATE USING THERMAL GRAVIMETRY AND INFRARED SPECTROMETRY

THERMAL AND ACTIVATION ENERGY OF RENEWABLE POLYMER AFTER UV IRRADIATION

Physico-chemical characterization and comparison of fluorinated commercial Ski-Waxes.

Halogen Free Flame Retardant Based on Organophosphorus Compounds for Expandable Polystyrene Produced by Supension Polymerization

Total analysis with DSC, TMA and TGA-EGA

Heat Transfer in Polymers

HYPHENATED TECHNOLOGY GUIDE

Analyzing & Testing Business Unit. Tau-R Mode for Advanced DSC Analysis Applications Newsletter 1/ /09, Dr. Stefan Schmölzer

At the Midpoint of the 2008

Supplementary Information

Automated, High- Throughput Data Processing & Quantification: Illustrated by a series of Non-Steroidal Anti-Inflammatory Drugs (NSAIDs)

DEVELOPMENT OF IMPROVED METHODS FOR CHARACTERISING THE CURE OF COMPOSITE MATERIALS

Chem Lab Pretest ( a combo of last year s exam, Vanier s lab manual and a few new questions.)

Thermal Methods of Analysis

ph-sensitive Nanocapsules with Barrier Properties: Fragrance Encapsulation and

3D Thermal-Diffusion Analysis on a Moisture Loaded Epoxy Sample

APPLICATIONS OF THERMAL ANALYSIS IN POLYMER AND COMPOSITES CHARACTERIZATION. Wei Xie TA Instruments

IBHS Roof Aging Program Data and Condition Summary for 2015

Effect of curing time on phenolic resins using latent acid catalyst

Supporting Information

CH3511 EXPERIMENT: Determination of Thermal Properties Using a Differential Scanning Calorimeter

Differential Scanning Calorimetry

School/Team Name: Team #: Chemistry Lab

Thermal and Mechanical Properties of EPR and XLPE Cable Compounds

ASSORTED STOICHIOMETRY PRACTICE PROBLEMS PART I

Chemical Reaction Engineering Prof. Jayant Modak Department of Chemical Engineering Indian Institute of Science, Bangalore

Petroleum Thermodynamic Research Group

Chapter 7. Gases, liquids, and solids. Water coexisting in three states H 2 O (g) in air H 2 O (l) ocean H 2 O (s) iceberg

HYPHENATED TECHNOLOGY GUIDE

2012 Thermodynamics Division C

Thermal and Mechanical Properties of EPR Cable Compound. Steven Boggs ICC Educational Session 7 November 2005 Phoenix, Arizona

Chemically recyclable alternating copolymers with low polydispersity from

F ( C) Cure Epoxy Resin System. Out life 30 days at 70 F (21 C)

SAULT COLLEGE OF APPLIED ARTS AND TECHNOLOGY SAULT STE. MARIE, ONTARIO COURSE OUTLINE

raw materials C V Mn Mg S Al Ca Ti Cr Si G H Nb Na Zn Ni K Co A B C D E F

EXPERIMENTALLY DETERMINING THE VISCOELASTIC BEHAVIOR OF A CURING THERMOSET EPOXY R. Thorpe 1, A. Poursartip 1*

How fast are chemical reactions?

CHEM 116 Phase Changes and Phase Diagrams

THERMOGRAVIMETRY ANALYSIS FOR CHARACTERIZATION OF MOLECULAR CONTAMINANTS IRRADIATED BY VUV RADIATIONS

Chemical Kinetics Ziyue Zhu 2015/2/4

Composition and Property Changes of HNBR & FKM Elastomers after Sour Gas Ageing C. Norris, M. Bennett, M. Hale & J. Lynch

PROGRAMMING THE RINSE ROBOT INTRODUCTION

Universal Standard Protocols for Temperature and Material Characterization Calibration with Pharmaceuticals by Thermal Analysis

December 19, November 10, 2011

HexPly F655 Resin Systems for Advanced Composites

2/22/2019 NEW UNIT! Chemical Interactions. Atomic Basics #19

The Ideal Gas Law INTRODUCTION DISCUSSION OF PRINCIPLES. Boyle s Law. Charles s Law. The Ideal Gas Law 10-1

Schedule. Draft Section of Lab Report Monday 6pm (Jan 27) Summary of Paper 2 Monday 2pm (Feb 3)

QUANTITATIVE EVALUATION OF CURING SHRINKAGE IN POLYMERIC MATRIX COMPOSITES

F ( C) Cure Epoxy Resin System. Out life 30 days at 70 F (21 C)

Calorimetry: differential scanning calorimetry (DSC), isothermal titration calorimetry (ITC)

Design technology Higher level Paper 1

2 Rates of Weathering

Supporting Information

Thermal degradation kinetics of Arylamine-based Polybenzoxazines

Certificate of Conformance

APPLICATION OF THERMAL METHODS IN THE CHEMISTRY OF CEMENT: KINETIC ANALYSIS OF PORTLANDITE FROM NON- ISOTHERMAL THERMOGRAVIMETRC DATA

Reactive Compatibilization of Polyethylene Terephthalate and High Density Polyethylene Using Amino-Telechelic Polethylene

High Performance Plastics Company (HPP)

ISO INTERNATIONAL STANDARD

Cyclo Dehydration Reaction of Polyhydrazides. 11. Kinetic Parameters Obtained from Isothermal Thermogravimetry

A new geomembrane for chlorinated water containment

BONDING FIRE RETARDANTS TO WOOD. PART I. THERMAL BEHAVIOR OF CHEMICAL BONDING AGENTS

Techniques in Thermal Analysis: Hyphenated Techniques, Thermal Analysis of the Surface, and Fast Rate Analysis

This document is a preview generated by EVS

Allotropes (Diamond and Graphite) Revision Pack (C3)

Communicating Research to the General Public

Evolved gas analysis by simultaneous thermogravimetric differential thermal analysis-fourier transformation infrared spectroscopy (TG-DTA-FTIR)

Uncover the insight with Hyphenation. Gerlinde Wita October 2015

Unit 1 Lab Equipment. Chemistry Midterm Review

ISO INTERNATIONAL STANDARD. Paints and varnishes Determination of volatile organic compound (VOC) content Part 1: Difference method

CARBONIZATION KINETICS OF COCONUT SHELL AND PLUM STONE

A Thesis Proposal. Agrawal, Ravi. Submitted to the Office of Graduate Studies of Texas A&M University

Transcription:

Tips and Techniques Reprinted From: PLASTICS TECHNOLOGY Magazine How to Use Kinetic Modeling Analysis To Predict Profile Part Failure Real-world project demonstrates how kinetic modeling can help estimate the shelf life of parts. In late 2014, Teel Analytical Laboratories, Baraboo, Wis., was approached by Connexicon Medical, a medical OEM based in Ireland, to investigate why a particular profile part was cracking. It By Dan P. Clark, Teel Analytical Laboratories was suspected that the cracking was related to the loss of the plasticizer through evaporation over time. The goal of the project was to confirm the evaporation and also determine how quickly it was occurring so that a shelf life for the product could be estimated. Teel Analytical Labs had recently acquired a software program for thermal analysis, which allowed it to predict the kinetic models of reactions or events that took place in its products. A kinetic model produced by Differential Scanning Calorimetry (DSC) or Thermogravimetric Analysis (TGA) is used to estimate the impact that time and temperature (and possibly atmosphere) have on a particular reaction or event. For example, if a chemical blowing agent is used in an extruded part, the kinetic model WHAT YOU WILL LEARN 1. KENETIC MODELING 101: A method to estimate the impact time and temperature have on a reaction/event. 2. DESIGNING EXPERIMENTS: Conduct at least three tests at varying parameters. 3. INTERPRETING RESULTS: Match a percentage with a temperature. 4. OTHER APPLICATIONS: Compounded mixture reactions. Teel Analytical Laboratories was tasked by a medical OEM to investigate why this profile (at 50x magnification )cracked. The cause was suspected to be related to the loss of the plasticizer through evaporation over time. By using kinetic modeling analysis, Teel confirmed the evaporation and also determined how quickly it was occurring so that a shelf life for the product could be estimated. can predict how much time it will take for it to fully react at different temperatures. One of the more significant advantages of the kinetic modeling analysis is the ability to predict these reactions or events at times or temperatures outside of the testing parameters. This means that if testing was conducted over a span of a few minutes or hours, the model could estimate what would happen in days or even weeks. Similarly, if the temperatures tested only spanned a few degrees, the model would be able to estimate effects of a larger temperature range. This prediction ability comes from the testing requirement of at least three points. That is, at least three different tests, with varying parameters, need to be performed in order to obtain an accurate model. Using the example of the chemical blowing agent, a possible testing outline might look like this: Test 1: Ramp 150 to 180 C @ 10 C/min., Isothermal 180 C for 120 min. Test 2: Ramp 150 to 185 C @ 10 C/min., Isothermal 185 C for 120 min. Test 3: Ramp 150 C to 190 C @ 10 C /min., Isothermal 190 C for 120 min.

PART FAILURE The results produced from these tests would show varying rates in which the chemical blowing agent reacts, allowing a model to be created. The different rates of the reaction can be seen in Fig. 1. The varying slopes of the curve signify the differences in the rate of weight loss. Since the weight loss in this case was an indication of the chemical blowing agent reaction, it was observed that the isothermal hold at 190 C produced the fastest reaction, followed by the isothermal hold at 185 C, and the slowest reaction at 180 C. The kinetic model can be produced from this data, and although the time and temperatures were limited to up to 120 min and 180 to 190 C, the model can predict a much broader range of times and temperatures (see Fig. 2). Figure 2 is the kinetic model from the isothermal data produced in Fig. 1. Note that the temperature range (first row) for this particular model spans from 150 C to 250 C. The percentages in the left column represent the completion of the reaction. It is important to note that the smallest weight loss at the far right of Fig. 1 is considered by the kinetic-modeling software to represent 100% reacted. This is how the software makes the calculation; ideally, your weight losses from each analysis are all similar so there isn t any bias when creating the kinetic model. That being noted, determining the tests to be conducted is critical to creating an accurate model. Interpreting the model table is as simple as matching a percentage with a temperature. For example, if you are interested in knowing how long it would take for 50% of the reaction to take place at 200 C, find where the row for 50% and the column for 200 C intersect. In this case, they intersect at a value of 4.83 which means it would take approximately 4.83 min for 50% of the chemical blowing agent to react at 200 C with heat alone. For chemical blowing agents, it is also important to note that other factors such as shear can impact the reaction rate, which is not taken into consideration in this model. So, in getting back to the original project request that Teel was presented with, the production and interpretation of this example model is similar to how the plasticizer evaporation rates were predicted. FIG 1 Example Analysis for Kinetics Modeling The kinetic model can predict how much time it will take for blowing agents to fully react at different temperatures. This ability comes from testing at least three points. The results from these tests show varying rates in which the chemical blowing agent reacts. The varying slopes of the curve signify the difference in the rate of weight loss. FIG 2 Reaction, % 20% Test 1 Test 2 Test 3 0 20 40 60 80 100 120 50% Kinetic Model from Isothermal Data Produced in Fig. 1 5 25 45 65 85 105 125 Conversion, minutes 150.0 C 160.0 C 170.0 C 180.0 C 190.0 C 200.0 C 210.0 C 220.0 C 230.0 C 240.0 C 250.0 C 10.0% 66.44 21.33 8.83 5.07 3.83 3.37 3.16 3.04 2.98 2.91 20.0% 89.41 28.57 11.24 5.92 4.14 3.49 3.21 3.07 2.99 2.92 30.0% 105.72 33.87 13.05 6.57 4.38 3.58 3.25 3.09 3.00 2.92 40.0% 38.74 14.71 7.16 4.60 3.67 3.28 3.10 3.01 2.93 50.0% 43.86 16.41 7.76 4.83 3.75 3.32 3.12 3.02 2.94 In this kinetic model from the isothermal data produced in Fig. 1, the temperature range (first row) spans from 150 C to 250 C. The percentages in the left column represent the completion of the reaction. It is important to note that the smallest final weight loss in Fig. 1 represents 100% reacted. Ideally, your weight losses are all similar so there isn t any bias when creating the kinetic model. 75.0% 60.48 21.98 9.71 5.55 4.03 3.44 3.18 3.05 2.96 90.0% 79.42 31.09 14.49 8.25 5.66 4.48 3.87 3.52 3.31

Tips & Techniques FIG 3 DSC Analysis Sample 1 (Part as Received) FIG 4 DSC Analysis Sample 2 (Part Exposed to Elevated Temperature) Heat flow 10 mw Midpoint ASTM, IEC 101.03 C Delta cp, IEC 0.168 Jg^-1K^-1 Heat flow 10 mw Midpoint ASTM, IEC 121.93 C Delta cp, IEC 0.256 Jg^-1K^-1 30 50 70 90 110 130 150 170 190 30 50 70 90 110 130 150 170 190 Temperature, C Temperature, C As the part was received, the glass-transition midpoint was found to be 101 C (Fig. 3) while the part that was exposed to elevated temperature experienced a large shift in the glass transition up to 122 C (Fig. 4). This shift was the evidence needed to support the theory that the plasticizer was evaporating out of the product post-production and was the likely cause of cracking. TGA Curve at 110 C FIG 5 FIG 6 TGA Curve at 200 C 0.5 mg Step -8.0746% -0.7073 mg Result Mode Sample Temp 0.5 mg Step -11.0492% -1.1546 mg Result Mode Sample Temp 0 800 1600 2400 3200 4000 4800 5600 6400 0 40 80 120 160 200 240 280 320 360 Each of the temperatures used to analyze the material was run for about 4.5 days using a TGA, held isothermally at that temperature. The total weight loss was then calculated for each test and the thermograms produced were used to create the kinetic model for the plasticizer weight loss. The 110 C and 200 C TGA curves are shown above. PLASTICIZER EVAPORATION ANALYSIS Since the cause of the cracking in the Connexicon Medical project seemed to have already been determined to be from plasticizer evaporation, initial tests were conducted to confirm that suspicion. DSC analysis was conducted on two profiles in order to provide that evidence. The first sample was a part tested as QUESTIONS ABOUT TESTING? Visit the Testing and Quality Control Zone. received, while the second was exposed to elevated temperatures to promote evaporation of the plasticizer. The results provided evidence that plasticizer was indeed evaporating (Figs. 3 and 4). As the part was received, the glass-transition midpoint was found to be 101 C, while the part that was exposed to elevated temperature experienced a large shift in the glass transition up to 122 C. This shift was the evidence needed to support the theory that the plasticizer was evaporating out of the product post-production and was the likely cause of the cracking. Initial testing was to be conducted on the sample at 50, 80, 110 and 140 C. But after the evaluation of the data, it was determined that a more

PART FAILURE expansive model could be created if the 50 and 80 C tests were dropped and 170 and 200 C tests were added. Making this change in the testing would improve the accuracy of the kinetic model and prevent any bias that may have come from the tests at 50 and 80 C. The need for this change was due to how the kinetic model equates the reaction percentages. Again, in weight-loss cases, the smallest loss will be used as 100% of the reaction. So, the closer that loss is to the true value in every test conducted, the more accurate the kinetic model. Tables 1 and 2 show two different sets of data. In these examples, it was found that 0.0200 g of weight loss was 100%. However, in the results shown in Table 1, the tests run at 50 and 80 If a chemical blowing agent is used in an extruded part, the kinetic model can predict how much time it will take for it to fully react at different temperatures. C fell short of that amount due to the length of time allotted at those temperatures. If these results were used to produce a kinetic model, 100% of the reaction would be attributed to the 0.0050 g weight loss at 50 C. This is obviously an issue, since it was determined after additional testing that the 0.0050 g loss is only 25% of the actual reaction. The results on Table 2 represent an ideal set of tests in which all the weightloss results were similar, with the only differences in the test being the temperature and how quickly the reaction occurred. Ideally, a portion of the testing to produce the kinetic model would be completed at a temperature comparable to real-world situations; but due FIG 7 Plasticizer Loss Kinetic Model Evaporation, % 50% Energy 50 kjmol^-1 0 4000 8000 12000 16000 10 30 50 70 90 Time, hr Conversion, % Conversion, hours 4.0 C 20.0 C 30.0 C 45.0 C 50.0 C 55.0 C 80.0 C 110.0 C 140.0 C 170.0 C 200.0 C 10.0% 7698.33 1531.25 610.82 172.25 116.14 79.20 13.86 2.34 0.51 0.14 45.03e-03 20.0% 13.77e+03 2803.32 1132.93 325.92 220.87 151.70 27.45 4.80 1.09 0.31 0.10 30.0% 13.00e+03 3555.06 1464.32 433.38 296.90 205.99 39.20 7.32 1.78 0.54 0.19 50.0% 6699.59 2815.29 857.52 592.77 414.80 82.22 16.01 4.05 1.26 0.46 75.0% 8521.35 3683.91 1175.11 825.33 587.09 127.02 27.72 7.91 2.78 1.15 90.0% 13.01e+03 5515.07 1722.33 1203.93 853.21 183.27 40.47 11.85 4.30 1.85 95.0% 13.39e+03 5701.10 1794.01 1257.50 893.72 195.11 44.10 13.25 4.95 2.19 99.5% 13.91e+03 5940.61 1879.87 1320.40 940.45 207.84 47.84 14.69 5.63 2.56 Combining the four curves produced by the TGA generated the kinetic model shown here. The table represents the kinetic model of the plasticizer lost through evaporation. The column on the left shows the percent loss of plasticizer from 10% to 99.5%, the top row shows the temperatures of interest and the body of the table is filled with time in hours.

Tips & Techniques to time constraints, the testing temperatures of 50 and 80 C were replaced with 170 and 200 C. Each of the temperatures used to analyze the material was run for about 4.5 days using a TGA, held isothermally at that temperature. The total weight loss was then calculated for each test and the thermograms produced were used to create the kinetic model for the plasticizer weight loss. The 110 C and 200 C TGA curves are shown in in Figs. 5 and 6. One of the more significant advantages of kinetic modeling analysis is the ability to predict reactions or events at times or temperatures outside of the testing parameters.. was distributed to Connexicon Medical for the temperatures and times of interest so that the shelf life of the part was better understood. ADDITIONAL KINETIC MODELING USES This article has described one of many different uses for the kineticmodeling software. Other projects for which Teel Analytical Laboratories has used this software include raw chemical foaming- TABLE 1 Example Kinetic Model Data 1 TABLE 2 Example Kinetic Model Data 2 Temperature Time Loss Percentage Temperature Time Loss Percentage 50 C 60 min 0.0050 g 25% 80 C 40 min 0.0100 g 50% 110 C 20 min 0.0200 g 100% 140 C 10 min 0.0200 g 100% 110 C 20 min 0.0200 g 100% 140 C 10 min 0.0200 g 100% 170 C 5 min 0.0200 g 100% 200 C 2 min 0.0200 g 100% Combining the four curves produced by the TGA generated the kinetic model shown in Fig. 7. The table in Fig. 7 represents the kinetic model of the plasticizer lost through evaporation. The column on the left shows the percent loss of plasticizer from 10% to 99.5%, the top row shows the temperatures of interest, and the body of the table is filled with time in hours. So if you wanted to estimate how long it would take for 50% of the plasticizer to be lost through evaporation at 30 C, we would simply determine where the 50% row and 30 C column intersect. In this case, the time would be roughly 2815 hr or around 117 days. Note that a few of the percentages under 4 C were left blank. This is due to the time setting applied to the model. In this model, a maximum time was set at two years. This means that in order for 50% of the plasticizer to evaporate at 4 C, it would take longer than two years. Upon completion of this project, a kinetic model agent reactions, compounded mixture reactions, and degradation kinetics. A few other common uses would be thermoset curing reactions, moisture or volatile loss kinetics, temperature-dependent reactions, and shelf-life determination. This software can be used for any reaction, curing, weight loss, or other thermal characteristic that can be measured on either a DSC or TGA. ABOUT THE AUTHOR: Dan P. Clark is the laboratory supervisor for Teel Analytical Laboratories in Baraboo, Wis., a division of custom profile processor Teel Plastics. He graduated from the University of Wisconsin La Crosse in 2007 with a degree in Biochemistry. He gained experience working in laboratories in the pharmaceutical, solar energy, and alternative fuel industries and has now been with Teel for three years. Contact: (608) 355-3080; dan.clark@teel.com; teel.com. Reprinted from the November 2016 PLASTICS TECHNOLOGY and Copyright 2016 by Gardner Business Media, Inc., 6915 Valley Ave., Cincinnati, Ohio 45244-3029.

Analyticaltesting Lab Dedicated to quality laboratory Laboratory Testing Services Teel Analytical Laboratories is a materials testing laboratory that focuses on polymer testing for plastics processors. The laboratory deals with polymer processes and materials on a daily basis and is in the best position to understand the issues that our customers face. Our ISO 17025 accredited laboratory can provide testing services for the following applications: Reverse Engineering Verifying the Quality of Incoming Materials Measuring the Consistency of Incoming Materials Determining Physical and Chemical Properties Failure Analysis Identifying Material Contaminants QA/QC Testing Method Development To discuss what test methods are needed for your particular application please contact our Laboratory Manager. Our experts can help you decide which test methods are right for you. For more information please contac: Dan Clark, Laboratory Supervisor 608-355-4626 dan.clark@teel.com Teel Plastics, Inc. 1060 Teel Ct. Baraboo, WI 53913 (608) 355-3080 www.teel.com