CapeSym, Inc. Radiation Detection Solutions

Similar documents
SCINTILLATION DETECTORS & GAMMA SPECTROSCOPY: AN INTRODUCTION

1 of :32

Wiper Gold Edition. Premium Wipe Test Counter. Setting the bar higher

DIGITAL PULSE SHAPE ANALYSIS WITH PHOSWICH DETECTORS TO SIMPLIFY COINCIDENCE MEASUREMENTS OF RADIOACTIVE XENON

Wiper Gold Edition. Premium Wipe Test Counter. Setting the bar higher

He-3 Neutron Detectors

hν' Φ e - Gamma spectroscopy - Prelab questions 1. What characteristics distinguish x-rays from gamma rays? Is either more intrinsically dangerous?

The Best Gamma-Ray Detector

28th Seismic Research Review: Ground-Based Nuclear Explosion Monitoring Technologies DESIGN OF A PHOSWICH WELL DETECTOR FOR RADIOXENON MONITORING

A Prototype of LaBr3:Ce in situ Gamma-Ray Spectrometer for Marine Environmental Monitoring

Chemical Engineering 412

Mass of the electron m 0

New Scintillators for the Border Monitoring Equipment

Gamma Spectroscopy. References: Objectives:

Dual Isotope Imaging with LaBr3:Ce Crystal and H8500 PSPMT

Design and production of Scintillation Detectors

RADIOACTIVITY IN THE AIR

Nuclear Lifetimes. = (Eq. 1) (Eq. 2)

Characterization and Monte Carlo simulations for a CLYC detector

4- Locate the channel number of the peak centroid with the software cursor and note the corresponding energy. Record these values.

Jazan University College of Science Physics Department. Lab Manual. Nuclear Physics (2) 462 Phys. 8 th Level. Academic Year: 1439/1440

RADEAGLET. Lightweight Handheld Radioisotope Identification Device

High Purity Germanium Detector Calibration at ISOLDE

Multi Channel Analyzer (MCA) Analyzing a Gamma spectrum

IdentiFINDER Digital Hand Held Spectrometer & Dose Rate Meter for Portable Applications

SCI-O11. Design of a Compton Spectrometer Experiment for Studying Electron Response of a Scintillator

AN34 Experiments in Nuclear Science Laboratory Manual Fourth Edition

Lawrence Berkeley National Laboratory Lawrence Berkeley National Laboratory

1 of 16 1/28/2014 2:35 PM. Search

Quality Assurance. Purity control. Polycrystalline Ingots

PYCKO SCIENTIFIC LIMITED

Ultra High Quantum Efficiency PMT for energy resolution measurements of LaBr 3 (Ce) scintillation crystals

Single Channel Beta-Gamma Coincidence Detection of Radioactive Xenon Using Digital Pulse Shape Analysis of Phoswich Detector Signals

Gamma Ray Spectroscopy

Scintillation Detector

High-efficiency and fast-timing scintillators

Nuclear Physics Laboratory. Gamma spectroscopy with scintillation detectors. M. Makek Faculty of Science Department of Physics

Sample Spectroscopy System Hardware

Researchers at the University of Missouri-Columbia have designed a triple crystal

NUCL 3000/5030 Laboratory 2 Fall 2013

Figure 1. Decay Scheme for 60Co

"Neutron Flux Distribution"

Pulse height non-linearity in LaBr 3 :Ce crystal for gamma ray spectrometry and imaging

QuantumMCA QuantumNaI QuantumGe QuantumGold

NORM Monitor-IS. Performance data

ORTEC Experiment 24. Measurements in Health Physics. Equipment Required

A new scintillator detector for nuclear physics experiments: the CLYC scintillator

Alpha particle scintillation detector based on micro pixel avalanche photodiode and LYSO crystal

SCINTILLATION DETECTORS AND PM TUBES

Alpha-Gamma discrimination by Pulse Shape in LaBr 3 :Ce and LaCl 3 :Ce

V. 3. Development of an Accelerator Beam Loss Monitor Using an Optical Fiber

Radiation Detection and Measurement

Radiation Dose, Biology & Risk

So, you want to build a neutrino detector?

THE COMPTON EFFECT Last Revised: January 5, 2007

WM2014 Conference, March 2 6, 2014, Phoenix, Arizona, USA

The Multi-Wiper HE. High Energy Nuclear Medicine Well Counter. The first multi-well counters designed specifically for Nuclear Medicine!

arxiv: v2 [physics.ins-det] 8 Feb 2013

Direct WIMP Detection in Double-Phase Xenon TPCs

Alpha-Energies of different sources with Multi Channel Analyzer

M E E T I n s t r u m e n t s G.m.b.H.

Preparatory experiments for cold-neutron induced fission studies at IKI

FoodScreen Radiological Food Screening System

Studies involving discrete spectroscopy. Studies involving total absorption or calorimetry

Compton suppression spectrometry

The Mössbauer Effect

Radiation Detectors. How do we detect ionizing radiation? What are these effects? Types of Ionizing Radiation Detectors

ARTICLE IN PRESS. Nuclear Instruments and Methods in Physics Research A

ORTEC AN34 Experiment 10 Compton Scattering

Characterization of the Lanthanum Chloride Scintillation Detector

GT-40/GT-40S Multipurpose Gamma-Ray Spectrometer Ancestors: GS-256 by Geofyzika Brno 1975 GR-256 by Exploranium Canada 1977 GR-320 by Exploranium

Gamma ray coincidence and angular correlation

Dependence Of Gamma Ray Attenuation On Concentration Of Manganese (II) Chloride Solution

LUDLUM MODEL 42-5 NEUTRON BALL CART. August 2015 Serial Number PR and Succeeding Serial Numbers

Radionuclide Imaging MII Detection of Nuclear Emission

Gamma-ray Spectroscopy with LaBr 3 :Ce Scintillator Readout by a Silicon Drift Detector

Alpha-energies of different sources with Multi Channel Analyzer (Item No.: P )

LaBr 3 (Ce) detector and PMT tests at IPN Orsay

Applied Nuclear Science Educational, Training & Simulation Systems

Studies of Hadron Calorimeter

Radiation Detection. 15 th Annual OSC Readiness Training Program.

Prospects for achieving < 100 ps FWHM coincidence resolving time in time-of-flight PET

Efficiency. Calculations for Selected Scintillators. > Detector Counting. Efficiency. > Photopeak Efficiency of Various Scintillation Materials

Interactive Web Accessible Gamma-Spectrum Generator & EasyMonteCarlo Tools

OPPORTUNITY TO JOIN IEEE AND NPSS

arxiv: v1 [physics.ins-det] 29 Jun 2011

Introduction to Radiation Monitoring

Response Function of the BGO and NaI(Tl) Detectors Using Monte Carlo Simulations

1/5 Specifications Hidex 300 SLL automatic TDCR liquid scintillation counter

The SpecMAT project: An array of gamma-ray detectors around an active gas target

Characterizing, Simulating, and Eliminating Vibration Induced Counts in Measurement While Drilling Gamma Ray Detectors. authors


Detection and measurement of gamma-radiation by gammaspectroscopy

Chapter 11: Neutrons detectors

New happenings in gamma spectroscopy data analysis Sylvie Ward Sales Support Specialist

MEDICAL EQUIPMENT: NUCLEAR MEDICINE. Prof. Yasser Mostafa Kadah

Non-Destructive Assay Applications Using Temperature-Stabilized Large Volume CeBr Detectors 14277

FRAM V5.2. Plutonium and Uranium Isotopic Analysis Software

Scintillation Detectors

List of Nuclear Medicine Radionuclides. Nuclear Medicine Imaging Systems: The Scintillation Camera. Crystal and light guide

Transcription:

ScintiClear Plug & Play Developer Kit

ScintiClear Developer Kit Our developer kit is a plug-and-play high energy resolution gamma spectrometer ready to measure in less than 30 minutes after the box is opened. It consists of a high performance ScintiClear scintillation crystal coupled to a super-bialkali photomultiplier tube (PMT), plug-on digital MCA with high voltage (usbbase) and browser-based graphical user interface. Table of contents: Kit description and graphical user interface 2 Developer kit drawing and overview 3 ScintiClear scintillation properties 4 Internal activity 5 Energy resolution 6 Performance versus count rate 7 Energy resolution versus temperature 8 manufactures novel scintillator crystals and other crystalline detectors at its 10,000 sq. ft. facility in Massachusetts, USA. Our products leverage decades of experience in crystal growth, materials science, chemistry, solid state physics, thermofluid transport, and engineering design. 1

Main features of the developer kit: USB-powered and controlled Web-browser base GUI Open source API in Python and C++ Energy resolution 3.3% at 662keV Low intrinsic activity High stopping power -30 C to +55 C operation temperature Digital pulse-shape acquisition capabilities 1.5 ScintiClear For digital data acquisition and analysis, usbbase from Bridgeport Instruments is used. The usbbase consists of an emorpho multi-channel analyzer and an integrated high voltage generator and divider to power the PMT. More information available at http://www.bridgeportinstruments.com 2

CapeSym s plug-and-play ScintiClear developer s kit makes high-energy resolution gamma spectroscopy easy. It consists of a ultra-high performance SrI 2 (Eu) scintillation crystal coupled to a PMT, plug-on digital MCA with high voltage and browser-based GUI. It can be used as a stand alone spectrometer, or as an OEM building block. Aluminum cap wall (0.5 mm thk) Reflector Ø1.5" x 1.5" hgt. ScintiClear crystal MuMetal magnetic shield Optical interface Super-bialkali PMT Aluminum canister Graphite-Epoxy composite outer shell usbbase 8-Position Thread Lock Connector, SwitchCraft EN3 mini Weathertight Mini B USB Connector, Bulgin, IP68, Thread Lock Dimensions Ø63.50mm x 197mm without connectors Manufacturer reserves the right to alter specifications 3

ScintiClear gamma detectors have a very high light output ranging from 80,000-100,000 ph/mev and energy resolutions as good as 2.9% at 662 kev even for large size crystals. Light Yield 80,000 ph/mev Density 4.59 g/cm 3 Energy Resolution @ 662keV 3.3% Decay Time 1-3 µs Emission Range Max Emission 400-480 nm 430 nm Z effective 49 Intrinsic activity 0.03-0.05 Bq/cm 3 Moisture Sensitivity Refractive Index 1.85 Hygroscopic (similar to NaI(Tl)) CapeSym's proprietary crystal growth process is now routinely producing crystals up to Ø2 and 4 long. The patent-pending process is based on decades of experience in crystal growth and crystal growth process simulation. 1-100 kev 100 kev-10 MeV SrI 2 (Eu) was originally proposed as a radiation detector by R. Hofstadter (U.S. Patent No. 3,373,279) in 1968. Due to unoptimized Eu concentration and longer than NaI(Tl) decay time, it did not draw significant attention at that time. In 2008 scientists from Lawrence Livermore National Laboratory (USA) spearheaded the development of SrI 2 (Eu) into a leading edge radiation detector. 4

Activity (Bq/cm 3 /kev) Because Strontium has a naturally stable isotopic composition, ScintiClear crystals enjoy the lowest intrinsic activity among high energy resolution scintillators available on the market. When compared to LaBr 3 (Ce), intrinsic activity of ScintiClear is up to forty times smaller. 10-3 ScintiClear TM A=0.052 Bq/cm 3 LaBr 3 (Ce) A=1.125 Bq/cm 3 10-4 10-5 10-6 0 500 1000 1500 2000 2500 3000 Energy (kev) The above chart shows the internal activity spectrum of a standard 1.5 ScintiClear kit in comparison with LaBr 3 (Ce), as measured inside a Pb castle with 2 inch thick walls. Strontium commonly occurs in nature, being the 15th most abundant element on Earth, estimated to average approximately 360 parts per million in the Earth's crust and is found chiefly as the sulfate mineral celestine (SrSO 4 ) and the carbonate strontianite (SrCO 3 ). Of the two, celestine occurs much more frequently in deposits of sufficient size for mining (from wikipedia.org). Although Strontium Iodide salt becomes corrosive when exposed to air, Strontium is fundamentally non toxic. Quarati et al. https://cds.cern.ch/record/1537367/files/p427.pdf 5

Counts When ScintiClear crystals are properly encapsulated, coupled to the photodetector and light collection is optimized, the energy resolution can be as good as 2.9% at 662keV and about 2.1% at 1332keV. Typical energy resolution for CapeSym s ScintiClear kit at 662keV: Ø1.0 3.1% Ø1.5 3.3% Ø2.0 3.3% 3500 3000 2500 2000 1500 1000 500 2.4% 2.2% 0 0 500 1000 1500 2000 2500 3000 Energy, kev Co-60 ScintiClear TM d46x62mm 3 Unambiguous Identification with ScintiClear 6

Photopeak position (channel) Photopeak position (%) Energy Resolution (%) ScintiClear developer s kit is a perfect solution for high-sensitivity radiation detection up 100,000 counts per second. 3.1 3.0 2.9 2.8 Energy Resolution at 662keV Decay time of ScintiClear crystals is size and shape dependent and ranges from 1 to 5μs on average. Typically integration time 10 to 20μs is required to achieve optimum energy resolution. 0.0 20.0k 40.0k 60.0k 80.0k Count Rate (cps) 670 668 666 664 662 660 658 137 Cs 662keV peak position 101.0 100.5 100.0 99.5 656 0.0 20.0k 40.0k 60.0k 80.0k Count Rate (cps) 99.0 7

Temperature, degc Energy Resolution at 662keV, % Our kit is fully functional in the temperature range from -30 C to +55 C and can tolerate temperature changes and thermal shock according to ANSI 42.34. Performance of every kit delivered to the customer is measured in a broad temperature range to ensure reliability and quality of performance. 60 40 1.5" ScintiClear-kit 137 Cs 10uCi source 3.2 20 3.0 0-20 -40 Temperature Energy resolution 0 10 20 30 40 50 Time, h 2.8 2.6 The coldest place on Earth is currently located in Antarctica, at the Russian Antarctic station Vostok. On July 21, 1983, this station recorded a temperature of 89.2 C ( 128.6 F). This is the lowest naturally occurring temperature ever recorded on Earth. The standard measuring conditions for temperature are in the air, 1.5 meters above the ground, and shielded from direct sunlight. The highest reliably recorded temperature on Earth is 54.0 C (129.2 F), it was recorded both in Death Valley, California on 20 June 2013, and in Mitribah, Kuwait on 21 July 2016. (from wikipedia.org) 8

2017 www.capesym.com