ZirChrom Newsletter Vol. #10 Sachtopore-NP and Sachtopore-RP, titania-based HPLC phases

Similar documents
Polymer Coated Titania for Analytical and Preparative Reversed-Phase Chromatography

Polymer Coated Titania for Analytical and Preparative Reversed-Phase Chromatography

LC and LC/MS Column Selection Flow Chart

Multi-mode Separations Using Zirconiabased Stationary Phases

Zirconia: the Ideal Substrate for Ion-Exchange LC and LC-MS

ZirChrom Columns and the Metalox 200-C High Temperature Liquid Chromatography Column Heater - The Future of HPLC has Arrived.

The Development of ZrO 2 Based HPLC: From Colloid to Column

Cation Exchange HPLC Columns

QUALITY HPLC COLUMNS PARTICLE PORE PAGE SIZE SIZE. C18 Bidentate C18 Extremely long column life and rugged 4um 100Å 3

Packings for HPLC. Packings for HPLC

LC Technical Information

Chapter content. Reference

penta-hilic UHPLC COLUMNS

mau 200 ph min

LC Columns with Liquid Separation Cell Technology

Optical Isomer Separation Columns and Packing Materials

for Acclaim Mixed-Mode HILIC-1 Column

Open Column Chromatography, GC, TLC, and HPLC

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

Comparison of different aqueous mobile phase HPLC techniques

Fast Analysis of Small MW Analytes in a Beverage and Serum Samples on a Zirconiabased Strong Anion-Exchanger

Dilution(*) Chromatography

Method Development with ZirChrom's Ion Exchange Phases

Welcome to our E-Seminar: Choosing HPLC Columns for Faster Analysis Smaller and Faster

Reversed Phase Solvents

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SIELC Primesep. Catalogue 9. Hichrom Limited

Alltech Alltima HP Introduction

Zirconia-Based Phases as a Powerful Complement to Silica-Based Phases for LC and LC-MS under Non-extreme Mobile Phase Conditions

Acclaim Mixed-Mode WCX-1

penta-hilic UHPLC COLUMNS

Isomer Separation on ZirChrom -CARB

Optimisil HPLC & UPLC Column catalogue

Liquid Chromatography

SRT -10/10C (10 µm ) Fast Protein Purification For FPLC, HPLC and Prep LC. Sepax Technologies, Inc. Preparative Size Exclusion Chromatography

High Pressure/Performance Liquid Chromatography (HPLC)

Packed Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS. Table of Contents

Reversed-Phase Method Development Guide

Sepax SRT -C, Zenix -C SEC Phases

How proteins separate on reverse-phase HPLC

High Performance Liquid Chromatography

Shodex TM ODP2 HP series columns

Course goals: Course goals: Lecture 1 A brief introduction to chromatography. AM Quality parameters and optimization in Chromatography

for Acclaim Mixed-Mode WCX-1

Validated HPLC Methods

Kromasil Eternity Designed for long life. For use in HPLC and UHPLC

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SeQuant ZIC-HILIC. Catalogue 9. Hichrom Limited

High Performance Liquid Chromatography

High Performance Liquid Chromatography

High Performance Liquid Chromatography

Analysis - HPLC A.136. Primesep 5 µm columns B.136

Kromasil Eternity Designed for long life

Biochemistry. Biochemical Techniques HPLC

Instrumental Chemical Analysis

Gemini-NX Performance paired with Axia Technology

A C18 Silica Column With Exceptional Temperature and ph Stability

New Applications of Zirconia Based Stationary Phases

1. Ion exchange chromatography

Chemistry Instrumental Analysis Lecture 28. Chem 4631

The Effect of Contact Angle and Wetting on Performance in Solid Phase Extraction

ProPac WCX-10 Columns

Yuhui Yang, An Trinh, Michael Ye, and Tom Henderson 595 North Harrison Road, Bellefonte, PA T HKB

Basic Principles for Purification Using Supercritical Fluid Chromatography

Characteristics and Advantages of Zirconia-Based Stationary Phases for Use in Multi-Dimensional HPLC

Chiral separations efficient, fast and productive

HPLC Preparative Scaleup of Calcium Channel Blocker Pharmaceuticals Application

Strategies for the Analysis of Therapeutic Peptides in Biofluids by LC-MS/MS. Lee Goodwin

Synthesis and Use of a New Covalently Bonded C18 Modified Carbon Clad Microporous Zirconia for Fast High Temperature Separations

for Acclaim Trinity TM P1

Simultaneous Determination of Paraquat and Diquat in Environmental Water Samples by HPLC-MS/MS

Guide to Choosing and Using Polymer Reversed Phase Columns!

ChromegaChiral TM CSP Media and Columns

Chromatographic Methods: Basics, Advanced HPLC Methods

STUDY OF LOADABILITY AND SELECTIVITY OF PHARMACEUTICAL COMPOUNDS ON RPLC COLUMNS

Novel LC/MS-Compatible Stationary Phase with Polar Selectivity

Agilent 1290 Infinity Quaternary LC Stepwise Transfer to Methods with MS-Compatible Mobile Phases

Oligonucleotide Separation on ZirChrom -SAX

Fast Separation of Vastly Different Compounds by Isocratic HPLC

Chiral Flash Columns

HPLC at High Temperature and High ph with a New, Highly Stable Silica Column

Hydrophilic Interaction Liquid Chromatography: Some Aspects of Solvent and Column Selectivity

Solid Phase Extraction Method Development Tips and Tricks

Product Bulletin. ACE LC/MS and Rapid Analysis HPLC Columns. HPLC Columns

C18 Column. Care & Use Sheet

Chemistry 3200 High Performance Liquid Chromatography: Quantitative Determination of Headache Tablets

Hints for Strong Ion Exchange Resins

Simultaneous estimation of amitryptyline and chlordiazepoxide by RP-HPLC method

Analysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography

Department of Chemistry

FAQ's. 1 - Which column would be the most appropriate for my application?

Ch.28 HPLC. Basic types of Liquid Chromatography Partition (LLC) Adsorption (LSC) Ion Exchange (IC) Size Exclusion (SEC or Gel Chromatography)

Retention and Selectivity Variables

No.106. Aqueous SEC Columns for Analysis of Cationic Polymers: TSKgel PWXL-CP Series. Contents. Page

Kromasil Eternity Designed for long life

Chemical Analysis Problem

ChromegaChiral TM CSP Media and Columns

Part 2. Overview of HPLC Media

On the Advantages and Costs of Two-dimensional HPLC (2D-LC)

8. Methods in Developing Mobile Phase Condition for C18 Column

Abstract: An minimalist overview of chromatography for the person who would conduct chromatographic experiments, but not design experiments.

Chromatographic Separation

Transcription:

ZirChrom Newsletter Vol. #10 Sachtopore-NP and Sachtopore-RP, titania-based HPLC phases Welcome to the tenth issue of ZirChrom's electronic newsletter. This newsletter introduces our titania-based HPLC phases, Sachtopore-NP and Sachtopore-RP. These new phases combine the increased thermal and chemical stability traditionally associated with zirconia-based phases with a wider range of pore and particle sizes. WHAT IS SACHTOPORE? Sachtopore is an inorganic, porous, HPLC stationary phase comprised of titanium dioxide (titania). The particles are spherical, monodisperse and are available in a wide range of well controlled particle and pore sizes. Figure 1 below shows a scanning electron micrograph of porous Sachtopore titania particles. Figure 1. Scanning electron micrograph of Sachtopore 100A, 5um (1) The surface chemistry of titania is quite different from the more traditional silica and polymer stationary phases, but is closely chemically related to zirconia. Like zirconia, the dominant surface features of titania includes: Brönsted acid, Brönsted base, and Lewis acid sites (see Figure 2). Figure 2. Surface Chemistry of Titania (Sachtopore-NP) (2)

Currently Sachtopore is available in normal and reversed-phase modes: Sachtopore-NP and Sachtopore-RP, respectively. Sachtopore-NP is a bare titania particle whereas Sachtopore-RP is polyethylene coated titania (see Figure 3). Both stationary phases are very chemically and thermally stable and offer unique chromatographic selectivity. Figure 3. Surface Chemistry of Sachtopore-RP (2) The Lewis acid site on the surface of titania plays a significant role in the chromatography of electrolytic analytes. The selectivity of the titania phases can be tuned by the ionic strength and type of buffer used (See Figures 4 & 5). These effects are predictable and follow the strength of Lewis acid-base interaction between the titania surface and the buffer. A stronger interaction with the titania results in a higher negative surface charge of the particle and greater retention of cationic solutes. The ionic retention mechanism can be reduced through the addition of salt to the mobile phase as shown in Figure 5 below. Figure 4. Effect of Lewis Base Additive on Separation of Basic Drugs. LC Conditions; Column: Sachtopore-RP (300A, 3um), 50 x 4.6 mm i.d. [part# TI01-0546-3(300)], Mobile phase: 30/70 ACN/20 mm buffer (ph=7), (A) ammonium acetate, (B) ammonium fluoride, (C) ammonium phosphate, Flow rate: 1.0 ml/min, Temperature: 40 C, Detection: UV, 254 nm, Solutes: (1) lidocaine, (2) quinidine, (3) tryptamine, (4) amitriptyline, and (5) nortriptyline. (2)

Figure 5. Effect of Ionic Strength on Separation of Basic Drugs. LC Conditions; Column: Sachtopore-RP (300A, 3um), 50 x 4.6 mm i.d. [part# TI01-0546-3(300)], Mobile phase: 30/70 ACN/phosphate buffer (ph=7), (A) 10 mm, (B) 15 mm, (C) 15 mm, Flow rate: 1.0 ml/min, Temperature: 40 C, Detection: UV, 254 nm, Solutes: (1) lidocaine, (2) quinidine, (3) tryptamine, (4) amitriptyline, and (5) nortriptyline. (2) Table 1 compares select physical and chemical properties of titania and zirconia. Both titania and zirconia have a large particle size availability, however only titania has a modifiable pore size. Despite this major difference the balance of physical and chemical properties are equivalent. The relative surface area (taking into account differences in specific gravity and pore size), coordination number and isoelectric point are all similar in magnitude. Titania is both chemically and thermally stable. TiO2 ZrO2 Porous particle size 3 80 3 25 range(um) Average pore diameter (Å) Modifiable (60 Å, 100 Å, 300Å 300 Å, 500 Å, 1000 Å, 2000 Å) Crystalline modification Anatase (60, 100, 300 A monoclinic b pore) - Rutile (2000 A pore) a Coordination number 6 a 7 b Isoelectric point (ph) 5.6 a 6.7 b ph stability range 1-14 (NP) a 1-12 (RP) 1-14 (PBD, CARB, PS, DB- C18)) Maximum temperature Up to 100C Up to 200C (CARB, DB- C18) a- Ref 1., b Ref 3 Table 1. Chemical and Physical properties of titania versus zirconia.

WHY CHOOSE SACHTOPORE? The Sachtopore phases combine the increased stability and unique selectivity traditionally associated with zirconia-based phases with the versatility of a wide range of pore and particle sizes. STABILITY The Sachtopore-RP material is shows no loss of retention or efficiency using ph range of 1-12 and temperature up to 100 C (see Figure 6 & 7). The Sachtopore-NP material (bare titania) shows no degradation using a ph range of 1-14, even using 1M NaOH as an eluent (1). Figure 6. Chemical stability of Sachtopore-RP. LC Conditions; Column: Sachtopore-RP (300A, 3um), 50 x 4.6 mm i.d. [part# TI01-0546-3(300)], Mobile phase: 15/85 ACN/0.1M Nitric acid, ph 1.0, or 0.01M Tetramethylammoniumhydroxide, ph 12.0, Flow rate: 1.0 ml/min, Temperature: 30 C, Injection volume: 5 ul, Detection: UV, 254 nm. (2) Figure 7. Temperature stability at 100 C of Sachtopore-RP. LC Conditions; Column: Sachtopore-RP (300A, 3um), 50 x 4.6 mm i.d. [part# TI01-0546-3(300)], Mobile phase: 15/85 ACN/water, Flow rate: 1.0 ml/min, Temperature: 100 C with Metalox heater, Injection volume: 5 ul, Detection: UV, 254 nm. (2)

SELECTIVITY A selectivity comparison utilizing a set of 22 non-electrolyte solutes were analyzed using Sachtopore-RP, ZirChrom-PBD, and a standard silica-c18 column. No major selectivity differences between the ZirChrom-PBD and Sachtopore-RP columns (see Figure 8. retention data normalized to benzene). Figure 8. 22 Non-electrolyte Solute Selectivity comparison. LC Conditions; Column: Sachtopore-RP (300A, 3um), 50 x 4.6 mm i.d. [part# TI01-0546-3(300)], Mobile phase: 40/60 ACN/Water, Flow rate: 1.0 ml/min, Temperature: 30 C, Injection volume: 5 ul, Detection: UV, 254 nm. (2) VERSITILITY The Sachtopore particle is highly versatile; allowing modification of both particle and pore size. A particle size range of 3 80 um and a pore size range of 60 2000A is currently available (see Figure 9). Figure 9. Scanning Electron Micrograph of 60, 100, 300, 2000 porous Sachtopore particles. (4) The stability and versatility of the Sachtopore phases make it ideal for large, production scale separations that could greatly benefit from the ability to use highly alkaline or acidic mobile phase or cleaning-in-place procedures. An example of the scalability of the product is shown in Figure 10. To simulate preparative chromatography conditions, Pentifylline, a vasodiliator, was extracted from a tablet of Cosaldon TM. Using 10 mm Na2B4O7 + 1 mm H3BO3 / 20% Acetonitrile (ph 9 in aqueous component) as mobile

phase the chromatogram shown in Figure 10 was obtained under overload conditions. The Pentifylline peak appeared with an almost rectangular shape Figure 10. Preparative separation of Pentifylline. Impurities were separated at retention time of 1.55, 2.07 and 4.22 minutes. LC Conditions; Column: Sachtopore-RP (300A, 3um), 150 x 4.6 mm i.d. [part# TI01-1546-3(300)], Mobile phase: (+ 10 mm Na2B4O7 + 1 mm H3BO3), ph 8.8, Flow rate: 1.0 ml/min, Temperature: ambient, Injection volume: 20 ul, Detection: UV, 254 nm. (5) RESEARCH & APPLICATIONS Titania is on the cutting-edge of biological, pharmaceutical, and normal phase applications method development. BIOLOGICAL Historically, researchers have been unable to fully realize the benefits of mass spectrometry as an analysis method for phosphopeptides because isolation of the molecules from non-phosphorylated peptides is frequently required before examination of the complex samples can proceed (6). Previously, immobilized metal affinity chromatography (IMAC) was the most widely utilized technique for phosphopeptide enrichment by mass spectroscopy. IMAC methods can vary widely in effectiveness depending on the type of metal ion and loading/elution procedure. The technique also uses valuable research time for the required metal ion loading and washing steps and is difficult to incorporate into an on-line application (6). As non-specific binding of nonphosphorylated peptides further hampers the technique, researchers using mass spectroscopy needed a more specific on-line technique for isolating the phosphopeptides in order to fully realize the time saving benefits of mass spectroscopy (6, 7). Recently, several papers have been published demonstrating the unique ability of titanium dioxide (titania) to selectively retain phosphopeptides contained in complex biological mixtures (6, 7). For example, Pinkse et al. report and innovative approach to automate the method for the enrichment of phosphopeptides using a 2D technique with titania dioxide particles as the first dimension and a reversed phase silica C18 column as the second dimension (6). The complex proteolytic digests were loaded onto the titanium dioxide pre-column using acidic conditions; retaining the phosphorylated peptides and allowing the rest of the

digest to concentrate on the reversed phase column. After the analysis of the digest peptides on the reversed phase column is complete the phosphopeptides are eluted, under alkaline conditions, from the titanium dioxide for analysis. The authors report the method has a recovery above 90% and allows for the identification of previously uncharacterized phosphorylation sites (6). Additionally, they report the titania precolumns could be used for over 200 runs without reduced performance (6). However, using this method the titania does appear to have non-specific binding issues especially of nonphosphorylated peptides with acidic residues. Larsen et al. took the Pinkse research one step further and dramatically improved the selectivity of the Pinkse method by loading the peptide samples onto the titania in 2,5- dihydrobenzoic acid (DHB) (7). In a direct comparison of the titania and IMAC methods for semi-complex samples the titanium dioxide pre-columns had a greater yield of phosphorylated peptides and fewer contaminating non-phosphorylated peptides (7). This effect was enhanced as the complexity of the samples increased (7). PHARMACEUTICAL Following are two of the many excellent examples of using reversed-phase titania for the separation of pharmaceutical compounds. Sachtopore-RP delivers excellent peak shape and selectivity for basic pharmaceuticals. Figure 11. Separation of Anithistamines at ph 10. LC Conditions; Column: Sachtopore- RP (300A, 3um), 150 x 4.6 mm i.d. [part# TI01-1546-3(300)], Mobile phase: 74% (50 mm H3PO4 + 5 mm KH2PO4), 26% ACN, ph 10, Flow rate: 1.0 ml/min, Temperature: ambient, Injection volume: 20 ul, Detection: UV, 220 nm. (5)

Figure 12. Separation of Basic Cardiac Drugs at ph 10. LC Conditions; Column: Sachtopore-RP (300A, 3um), 150 x 4.6 mm i.d. [part# TI01-1546-3(300)], Mobile phase: 70% (10 mm Borax + 10 mm Soda), 30% ACN, ph 10, Flow rate: 1.0 ml/min, Temperature: ambient, Injection volume: 20 ul, Detection: UV, 230 nm. (5) NORMAL PHASE The unique crystalline structure and surface chemistry of Sachtopore-NP enables the separation in normal phase of many basic and isomeric compounds (Figure 13 & 14). Figure 13. Separation of isomers of chloraniline in gradient elution on Sachtopore-NP. LC Conditions; Column: Sachtopore-NP (100A, 5um), 150 x 4.6 mm i.d. [part# TI02-1546-5(100)], Mobile phase: n-heptane / 2-propanol, gradient elution from (99/1) to (19/81) in 4 min, Flow rate: 1.5 ml/min, Temperature: 43 C, Detection: UV, 245 nm, Solutes: (a) 2,3-Dichloroaniline, (b) 2-chloroaniline, (c) 2,4-dichloroaniline, (d) 3- chloroaniline, (e) 3,4-dichloroaniline. (1)

Figure 14. Separation of amitryptyline and noramitryptyline on Sachtopore-NP. LC Conditions; Column: Sachtopore-NP (100A, 5um), 150 x 4.6 mm i.d. [part# TI02-1546- 5(100)], Mobile phase: dichloromethane / methanol [(TFA) (93:7) (0.2%), v/v], Flow rate: 1.0 ml/min, Temperature: ambient, Detection: UV, 254 nm, Solutes: (a) amitryptyline, (b) noramitryptyline. (1) SUMMARY Sachtopore is an inorganic, porous, HPLC stationary phase comprised of titanium dioxide (titania). The surface chemistry of titania is quite different from the more traditional silica and polymer stationary phases, but is closely chemically related to zirconia. The increased stability, unique selectivity and versatility of Sachtopore, both in reversed and normal phase modes, make it an excellent choice for cutting edge HPLC analytical and preparatory method development. Currently Sachtopore offers two phases: Sachtopore-NP and Sachtopore-RP. Sachtopore-NP and Sachtopore-RP are available from ZirChrom in bulk or packed columns. Also available from Glygen are the Lab-in-a-Tip SPE pipette tips containing Sachtopore particles (Figure 15). Figure 15. Glygen s Lab-in-a-tip SPE pipette tips More information on Sachtopore bulk, packed columns, or Glygen s Lab-in-a-tip SPE pipette tips is available on our website at www.zirchrom.com or by contacting a ZirChrom technical specialist by phone at 1-866-STABLE-1 or by e-mail at support@zirchrom.com.

REFERENCES (1) Winkler, J.; Marme, S., Journal of Chromatography A 2000, 888, 51-62. (2) McNeff, C.; Yan, B.; Winkler, J. PITTCON 2005 ORAL PRESENTATION. (3) Nawrocki, J.; Rigney, M. P.; McCormick, A.; Carr, P.W., Journal of Chromatography A, 1993, 657, 229-282. (4) Winkler, J.; Marme, S.; Hirthe, B.; Benkner, G.; Wittenburg, R.; Trüdinger, U., PREP 1999 POSTER PRESENTATION. (5) Winkler, J.; Hirthe, B.; Benkner, G.; Blome, J.; Spitzwieser, C.; Wittenburg, R. PREP 2004 POSTER PRESENTATION. (6) Pinkse, M.W.H.; Uitto, P.M.; Hilhorst, M.J.; Ooms, B.; Heck, A.J.R., Analytical Chemistry 2004, 76, 3935-3943. (7) Larsen, M.R.; Thingholm, T. E.; Jensen, O.N.; Roepstorff, P.; Jorgensen, T.J.D., Mol Cell Proteomics, 2005, 4, 873-886.