Degrees of Protection IEC 60529

Similar documents
Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH

Amphenol. Amphenol-Tuchel Electronics GmbH. Circular Connectors C 091 A/B/D Series

TEST REPORT ENVIRONMENTAL EN 60529:1991+A1:2000

TEST REPORT RP

T20WN. Data Sheet. Torque transducers. Special features. Installation example with bellows couplings. B en

H i g h A m p e r a g e 2 5 t o A M P. T y p e I & I I I V e h i c l e P r o t e c t i o n. I P 6 7 W a t e r p r o o f

Installation guide 862 MIT / MIR

INSTITUTE OF TESTING AND CERTIFICATION (INDIA) PVT.LTD.

/2 way valves (solenoid actuated diaphragm with forced lifting) 1/4... 2

Operating Instructions for Digital Manometer. Model: MAN-SD

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27

For Customer Service, Rev A - 6/ OF 6

S.C. Rulmenti S.A. Barlad Romania Republicii Street No

Universal bumper to frame hitch for 27,000 33,000 lbs. GVWR trucks. Optional: carbide cutting edge, mushroom shoes, snow deflectors

Internal Components Forms of Separation

Pumps type MP Motor pump combination for mounting into tanks for on/off service

ATEX/IECEx RTD temperature probe

To be used for reference only. Property of Arc Machines, Inc.

Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level

STATIC GAS MONITOR Type SGM/DEW Revision A of 20 aprile 2016

WINTER SAFETY CHECKLIST for those with rail tracks

Exchangeable measuring insets SensyTemp TSA101

General. High Winds. High winds are a common hazard in the UAE.

E8EB-N0C2B E8EB-N0B2B

AC axial fan. Limited partnership Headquarters Mulfingen Amtsgericht (court of registration) Stuttgart HRA

2.12. Ex-Linear light fittings for fluorescent lamps - max. ambient temperature + 60 C - nllk W - 58 W for Zone 2 and 22

PRODUCT SPECIFICATIONS

ISEmax CAS40D. Technical Information

Pumps type MP Motor pump combination for mounting into tanks for on/off service

EX-EMERGENCY LIGHT FITTINGS

Supersonic air and wet steam jet using simplified de Laval nozzle

Dimensional drawing face mount flange radial. R = bending radius min. 40 mm. Dimensional drawing face mount flange axial

AC axial compact fan

THE DIMENSIONING OF ELECTRICAL CONDUCTORS FOR USE IN "PANEL BOARDS" ADDRESSED TO HAZARDOUS AREAS - PART THREE

Pressure transmitters for industrial applications MBS 32 and MBS 33

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

CONTINUOUS FINE DUST MEASURING SYSTEM

Unit 1: Fire Engineering Science (A/505/6005)

3.1 Materials The housing is 316 stainless steel (excluding the connector shell which is 303 or better).

The slimmest Panel with highest efficacy in the market

DRS 61: Incremental encoders, number of lines and zero pulse width freely programmable DRS 60: Incremental Encoders with Zero-Pulse-Teach

SolderSleeve Devices Specification For Commercial Wire Splices. Table of Contents

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

AC axial compact fan

1. Explain the various methods of methods of grounding. In power system, grounding or earthing means connecting frame of electrical equipment (non-cur

Conductive Polymer Capacitors

AC axial compact fan

DETERMINATION OF THE DIELECTRIC STRENGTH OF LPS COMPONENTS BY APPLICATION OF THE CONSTANT-AREA-CRITERION

Page 2 of 14 Report Ref. No

Field IT 50T Series Transmitters

2W, 2816, SL Type Low Resistance Chip Resistor (Lead / Halogen Free)

Training program for x-ray inspection film (RT)

VX25 Enclosure System. Technical documentation PE conductor connection, current carrying capacity

Film Capacitors. EMI suppression capacitors. Date: June 2018

ELMO-G Vacuum Pumps/Compressors, Range 2BH1, Three-Phase 50 Hz

TEST REPORT IEC/EN Circuit-breakers for over current protection for household and similar installations

Chemical Receiving Safety. Joel Anderson, Chief Operator Sebago Lake Water Treatment Facility Portland Water District

PULSE TOTAL STATION GPT-3000(L)N SERIES

DRIFTER PLOW-IN-A-BOX ASSEMBLY / OWNER S MANUAL

LD-LP-LL-LC Rope Safety Switches with reset for emergency stop

Product Data Sheet PD-0037-B

CALEFFI. Modulating digital controller for heating and cooling. 161 series 01122/08 GB. replaces dp 01122/05

ct m ive p 5/EC Thermal cut-outs

Varius SUMMARY OF MODELS OF HRC FUSE-LINKS. Type PVA10 / PV10 PV14 PV22 Rated current I n up to 32 A up to 63 A up to 125 A Rated voltage U n

TCLT10.. Series. Optocoupler with Phototransistor Output. Vishay Semiconductors. Description. Applications. VDE Standards

PHASED OUT. LED light engine / OLED LED compact. Module SLE G4 6mm R SNC, SLE G4 10mm R SNC China domestic Modules SLE ESSENCE

ph/redox Measurement CPM 280

LED light engine / OLED LED compact. Module DLE G4 ADV Modules DLE

Electrical Safety of Low-Voltage Systems

ISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER

Proximity Sensor Ideal for High Temperatures and Cleaning Processes. Applicable to 120 C

LED light engines LED compact. Module DLE G4 ADV Modules DLE

Non-Contact Safety Systems CMS

Lab in a Box Millikan s oil drop experiment

LED light engines LED linear / area. Module RLE 2x6 EXC2 OTD Modules RLE EXCITE

TEST REPORT IEC :2002 Circuit-Breakers for overcorrect protection for household and similar installation

Unit 1 Fire Engineering Science (Zone 1)


Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

2.12. Ex-Linear light fittings for fluorescent lamps. nllk W - 58 W (Zone 2, 21, 22)

ISO 6530 INTERNATIONAL STANDARD

SINEAX VK 626 Programmable Temperature Transmitter for RTD and TC inputs, with HART protocol

M I N I S T R Y O F C O M M U N I C A T I O N S T E L E C O M M U N I C A T I O N S S E C T O R T E C H N I C A L S T A N D A R D F O R

LED modules LED linear / area. Module RLE 2x6 EXC2 OTD Modules RLE excite

Operating instructions Magnetic-inductive flow meter SM6x04 SM7x04 SM8x04

MSBCCL Series Asynchronous Three-Phase Brake Motors With Squirrel Cage Rotor Direct Current Brake

Paper submitted to: Physical Review Letters. Title: The energy distribution structure and dynamic characteristics of energy release in

Applied Fluid Mechanics

ASMT-YTB2-0BB02. Data Sheet. High Brightness Tricolor PLCC6 Black Surface LED. Features. Description. Applications

PUSH TUBE STANDARD DUTY

Applied Fluid Mechanics

Identification File of Type ZE64G23

Commercial Generator Parts Catalog. PROTEC Series

SN54HC20, SN74HC20 DUAL 4-INPUT POSITIVE-NAND GATES

ABB MEASUREMENT & ANALYTICS DATA SHEET. PGC5000 Temperature programmed gas chromatograph

NYY-J/-o 34 NYCWY 36 NYCY 37 NAYY 38

Explosion-protected recessed ceiling LED-light and fluorescent light fittings

Use of Thermography and Ultrasonic Inspection for Evaluation of Crimped Wire Connection Quality

Review of Anemometer Calibration Standards

Transcription:

IEC 60529 IP-Code system Simon Bakker 09-03-2016 MASER Engineering www.maser.nl 1

Specifications IEC 60529 NEN-EN-ISO 20653 DIN 40050 MIL-STD 810, Method 506 + 510 NEMA 250... MASER Engineering www.maser.nl 2

Definition (IEC 60529) Protection of persons against access to hazardous parts inside the enclosure. Protection of the equipment inside the enclosure against ingress of solid foreign objects. Protection of the equipment inside the enclosure against harmful effects due to the ingress of water. Enclosure: A part providing protection of equipment against certain external influences and, in any direction, protection against direct contact. MASER Engineering www.maser.nl 3

The IP Code Code letter (International Protection) First characteristic number (0 to 6, or X) Second characteristic number (0 to 9, or X) Additional letter (optional) (A, B, C, D) Supplemental letter (optional) (H, M, S, W) (example) IP 2 3 C H MASER Engineering www.maser.nl 4

IPX- : Acces to hazardous parts First Characteristic Number Description of Protection Against... 0 No Protection --- Definition 1 Access to hazardous parts with the back of a hand 2 Access to hazardous parts with a finger The access probe, sphere of 50 mm, shall have adequate clearance from hazardous parts The jointed test finger of 12 mm, 80 mm length, shall have adequate clearance form hazardous parts 3 Access to hazardous parts with a tool The access probe of 2,5 mm shall not penetrate 4 Access to hazardous parts with a wire The access probe of 1,0 mm shall not penetrate 5 Access to hazardous parts with a wire The access probe of 1,0 mm shall not penetrate 6 Access to hazardous parts with a wire The access probe of 1,0 mm shall not penetrate MASER Engineering www.maser.nl 5

IPX- : Acces to hazardous parts First Characteristic Number IP X- Probe Description of Protection Against... 0 No Protection --- Definition 1 Access to hazardous parts with the back of a hand 2 Access to hazardous parts with a finger The access probe, sphere of 50 mm, shall have adequate clearance from hazardous parts The jointed test finger of 12 mm, 80 mm length, shall have adequate clearance form hazardous parts 3 Access to hazardous parts with a tool The access probe of 2,5 mm shall not penetrate 4 Access to hazardous parts with a wire The access probe of 1,0 mm shall not penetrate 5 Access to hazardous parts with a wire The access probe of 1,0 mm shall not penetrate 6 Access to hazardous parts with a wire The access probe of 1,0 mm shall not penetrate MASER Engineering www.maser.nl 6

IPX- : Ingress of Solide foreign objects First Number Description of Protection Against... 0 No Protection --- Definition 1 Solid foreign objects of 50 mm and greater (50 N) 2 Solid foreign objects of 12,5 mm and greater (30 N) 3 Solid foreign objects of 2,5 mm and greater (3 N) 4 Solid foreign objects of 1,0 mm and greater (1 N) The object probe, sphere, shall not fully penetrate The object probe, sphere, shall not fully penetrate The object probe, sphere, shall not penetrate at all The object probe of 1,0 mm, shall not penetrate at all 5 Dust-protected Ingress of dust is not totally prevented, but dust shall not penetrate in a quantity to interfere with satisfactory operation of the apparatus or to impair safety 6 Dust-tight No ingress of dust MASER Engineering www.maser.nl 7

First Number IPX- : Acceptance Access To Hazardous Parts 0 No test required Solid Foreign Object 1 The sphere of 50 mm shall not fully penetrate and adequate clearance shall be kept 2 The jointed test finger may penetrate up to its 80 mm length, but adequate clearance shall be kept The sphere of 12,5 mm shall not fully penetrate 3 The test rod of 2,5 mm shall not penetrate and adequate clearance shall be kept 4 The test wire of 1,0 mm shall not penetrate and adequate clearance shall be kept 5 The test wire of 1,0 mm shall not penetrate and adequate clearance shall be kept 6 The test wire of 1,0 mm shall not penetrate and adequate clearance shall be kept Ingress of dust is not totally prevented, but dust shall not penetrate in a quantity to interfere with satisfactory operation of the apparatus or to impair safety No ingress of dust MASER Engineering www.maser.nl 8

IP-X : Ingress of Water Second Number Test means 0 No test required --- Duration of test 1 Drip box, enclosure on turntable 1 mm/min, 10 min 2 Drip box, enclosure in 4 fixed positions of 15 tilt 3 Oscillating tube, ±60 from vertical max. 200 mm distance Or spray nozzle showerhead ±60 from vertical 4 Oscillating tube, ±180 from vertical max. 200 mm distance Or spray nozzle showerhead all sides 5 Water jet hose nozzle 6.3 mm, 2.5m to 3 m distance 6 Water jet hose nozzle 12.5 mm, 2.5m to 3 m distance 7 Immersion tank Water 0.15m above top of enclosure, water 1m above bottom of enclosure 8 Immersion tank Waterlevel by agreement 9 Fan jet nozzle, enclosure on turntable, 0 /30 /60 /90 3 mm/min, 2.5 min for each position of tilt 0.07 l/min per hole by number of holes, 10 min 10 l/min, 1 min/m 2, at least 5 min 0.07 l/min per hole by number of holes, 10 min 10 l/min, 1 min/m 2, at least 5 min 12.5 l/min, 1 min/m 2, at least 3 min 100 l/min, 1 min/m 2, at least 3 min 30 min By agreement 15 l/min, 80 C, 30 s per position(small units), 1 min/m 2, at least 3 min (large units) MASER Engineering www.maser.nl 9

IP-X : Ingress of Water Second Number Test means 0 No test required --- Duration of test 1 Drip box, enclosure on turntable 1 mm/min, 10 min 2 Drip box, enclosure in 4 fixed positions of 15 tilt 3 Oscillating tube, ±60 from vertical max. 200 mm distance Or spray nozzle showerhead ±60 from vertical 4 Oscillating tube, ±180 from vertical max. 200 mm distance Or spray nozzle showerhead all sides 5 Water jet hose nozzle 6.3 mm, 2.5m to 3 m distance 6 Water jet hose nozzle 12.5 mm, 2.5m to 3 m distance 7 Immersion tank Water 0.15m above top of enclosure, water 1m above bottom of enclosure 8 Immersion tank Waterlevel by agreement 9 Fan jet nozzle, enclosure on turntable, 0 /30 /60 /90 3 mm/min, 2.5 min for each position of tilt 0.07 l/min per hole by number of holes, 10 min 10 l/min, 1 min/m 2, at least 5 min 0.07 l/min per hole by number of holes, 10 min 10 l/min, 1 min/m 2, at least 5 min 12.5 l/min, 1 min/m 2, at least 3 min 100 l/min, 1 min/m 2, at least 3 min 30 min By agreement 15 l/min, 80 C, 30 s per position(small units), 1 min/m 2, at least 3 min (large units) MASER Engineering www.maser.nl 10

IP Code Considerations IP Code applies only to new enclosures IP Code applies to electrical equipment rated voltage not exceeding 72.5kV In the IEC 60529 impact tests are no longer defined (replaced by IK code in IEC 62262) Code IPX9 added to IEC 60529 Still no K coding in IEC 60529, though described in IEC 20653; road vehicles Checkability of ingress...avoid wrong conclusions due to inspection sequence Use common sense, it is your best help! MASER Engineering www.maser.nl 11

Additional Letters If the actual protection against access to hazardous parts is higher than that indicated by the first characteristic numeral If only the protection against access to hazardous parts is indicated, the first characteristic numeral being then replaced by an X. Additional Letter Description of Protection Against... Definition A Access with back of the hand The access probe, sphere of 50 mm, shall have adequate clearance from hazardous parts B With finger The jointed test finger of 12 mm, 80 mm length, shall have adequate clearance form hazardous parts C With tool The access probe of 2,5 mm, 100 mm length, shall have adequate clearance from hazardous parts D With wire The access probe of 1,0 mm, 100 mm length, shall have adequate clearance from hazardous parts MASER Engineering www.maser.nl 12

Supplementary Letters Supplementary information describes exceptional cases Additional Letter Definition H M S W High-voltage apparatus Tested for harmful effects due to the ingress of water when the movable parts of the equipment (for example, the rotor of a rotating machine) are in motion Tested for harmful effects due to the ingress of water when the movable parts of the equipment (for example, the rotor of a rotating machine) are stationary Suitable for use under specified weather conditions and provided with additional protective features or processes MASER Engineering www.maser.nl 13

Examples: Systems Level IPX2 IP4X MASER Engineering www.maser.nl 14

Examples: Component Level IPX7 IP5X MASER Engineering www.maser.nl 15