Thermoelastic study of an aluminum component using an automatic correction procedure of data acquired in non-adiabatic conditions

Similar documents
DEVELOPMENT OF THERMOELASTIC STRESS ANALYSIS AS A NON-DESTRUCTIVE EVALUATION TOOL

An innovative method to measure stress distribution of a wind turbine model by thermoelasticity

MEASUREMENT OF STRESS PATTERN ON ROLL BEARING SUPPORTS BY THERMOELASTICITY

Analysis of Thermal Stress in Fatigue Fracture Specimen using Lock-in Thermography

A Portable Optical DSPI System for Residual Stresses Measurement by Hole Drilling Using the Integral Method in Terms of Displacement

MEASUREMENT BY THERMOELASTICITY ON PLASTIC FAN BLADE. A. Di Renzo, M. Marsili, M. Moretti, G.L. Rossi

SUB-SURFACE DAMAGE LOCATION AND IDENTIFICATION USING INFRA-RED TECHNIQUES

APPLICATION OF THERMOGRAPHY TO ANALYSIS OF THERMAL STRESS IN THE NDT FOR COMPACT TENSILE SPECIMEN

Finite element simulation of residual stresses in laser heating

Deflections and Strains in Cracked Shafts due to Rotating Loads: A Numerical and Experimental Analysis

Bending Load & Calibration Module

THE USE OF INFRA RED DETECTORS FOR DETERMINATION OF THE FRACTURE MECHANICS PARAMETERS

Mechanical Engineering Ph.D. Preliminary Qualifying Examination Solid Mechanics February 25, 2002

Vibration based Fatigue Damage Assessment of Cantilever Beams

Dynamics of structures

Mechanical Engineering Journal

Software Verification

(Refer Slide Time: 1: 19)

Deflections and Strains in Cracked Shafts Due to Rotating Loads: A Numerical and Experimental Analysis

Experiment Five (5) Principal of Stress and Strain

MECE 3321 MECHANICS OF SOLIDS CHAPTER 3

MECHANICS OF MATERIALS. Prepared by Engr. John Paul Timola

MAAE 2202 A. Come to the PASS workshop with your mock exam complete. During the workshop you can work with other students to review your work.

STRAIN ASSESSMENT USFOS

Strength of Material. Shear Strain. Dr. Attaullah Shah

ENG2000 Chapter 7 Beams. ENG2000: R.I. Hornsey Beam: 1

Developments in Visual and Other NDE Methods II

Available online at ScienceDirect. 5th Fatigue Design Conference, Fatigue Design 2013

File name: Supplementary Information Description: Supplementary Figures, Supplementary Tables and Supplementary References

MEASUREMENT OF THERMAL STRESS AND PREDICTION OF FATIGUE FOR STS USING LOCK-IN THERMOGRAPHY

Matlab Sheet 2. Arrays

MECE 3321: Mechanics of Solids Chapter 6

Thermal deformation compensation of a composite beam using piezoelectric actuators

MET 487 Instrumentation and Automatic Controls. Lecture 13 Sensors

Jeff Brown Hope College, Department of Engineering, 27 Graves Pl., Holland, Michigan, USA UNESCO EOLSS

THERMAL COATING CHARACTERIZATION USING THERMOELASTICITY

RESIDUAL STRESS MEASUREMENT IN STEEL BEAMS USING THE INCREMENTAL SLITTING TECHNIQUE

An aircraft structural health monitoring using Brillouin scattering sensing system

[8] Bending and Shear Loading of Beams

Non contact measurements of stress fields on rotating mechanical components by thermoelasticity

Mechanics of Inflatable Fabric Beams

The University of Melbourne Engineering Mechanics

DETERMINING THE STRESS PATTERN IN THE HH RAILROAD TIES DUE TO DYNAMIC LOADS 1

SYSTEM IDENTIFICATION & DAMAGE ASSESSMENT OF STRUCTURES USING OPTICAL TRACKER ARRAY DATA

FATIGUE DAMAGE ASSESMENT USING THERMOELASTIC STRESS ANALYSIS

Schöck Isokorb Type S22 and S16

FVM for Fluid-Structure Interaction with Large Structural Displacements

FABRICATION, TESTING AND CALIBRATION OF TWO DIRECTIONAL FORCE SENSOR

Communication. Provides the interface between ground and the spacecraft Functions:

Strain Measurements. Isaac Choutapalli

STRUCTURAL ANALYSIS OF THE LIFTING DEVICE DETECTOR SUPPORTS FOR THE LHCb VERTEX LOCATOR (VELO)

Operating Deflection Shapes from Strain Measurement Data

MEMS Report for Lab #3. Use of Strain Gages to Determine the Strain in Cantilever Beams

Address for Correspondence

Lecture 20. Measuring Pressure and Temperature (Chapter 9) Measuring Pressure Measuring Temperature MECH 373. Instrumentation and Measurements

Detection of Subsurface Defects using Active Infrared Thermography

Strain Measurement Techniques for Composite Coupon Testing

Virtual Work & Energy Methods. External Energy-Work Transformation

Extended Thermoelastic Stress Analysis Applied to Carbon Steel and CFRP

FRACTURE MECHANICS OF COMPOSITES WITH RESIDUAL STRESSES, TRACTION-LOADED CRACKS, AND IMPERFECT INTERFACES

Thermal Analysis. with SolidWorks Simulation 2013 SDC. Paul M. Kurowski. Better Textbooks. Lower Prices.

ANALYSIS AND EXPERIMENT OF DYNAMIC CHARACTERISTICS OF ELECTRONIC DEVICE CHASSIS

Aluminum shell. Brass core. 40 in

University of Bristol - Explore Bristol Research. Publisher's PDF, also known as Version of record

Fundamentals of Ultrasonics

Mech Eng Dept, University of Bristol, UK

RODS: THERMAL STRESS AND STRESS CONCENTRATION

EE C245 ME C218 Introduction to MEMS Design

Revealing bending and force in a soft body through a plant root inspired. approach. Lucia Beccai 1* Piaggio 34, Pontedera (Italy)

ME Final Exam. PROBLEM NO. 4 Part A (2 points max.) M (x) y. z (neutral axis) beam cross-sec+on. 20 kip ft. 0.2 ft. 10 ft. 0.1 ft.

Elastic Properties of Solids (One or two weights)

Numerical Modelling of Dynamic Earth Force Transmission to Underground Structures

Discrete Element Modelling of a Reinforced Concrete Structure

Cork Institute of Technology. Autumn 2007 Mechanics of Materials (Time: 3 Hours)

Preliminary Design Review: Loads, Structures, and Mechanisms. Michael Cunningham, Shimon Gewirtz, Rajesh Yalamanchili, Thomas Noyes

The science of elasticity

Nonlinear Elastic Analysis of Structural Frame Under Dynamic Load Condition

Dynamic analysis of a reinforced concrete shear wall with strain rate effect. Synopsis. Introduction

Part 7. Nonlinearity

Schöck Isokorb Type S22 and S16

Thermo-Structural Analysis of Thermal Protection System for Re-Entry Module of Human Space Flight

FEM STUDIES ON INCREMENTAL FORMED AND MACHINED SATELLITE STRUCTURES

Massachusetts Institute of Technology Department of Aeronautics and Astronautics Cambridge, MA Problem Set 14

Stress-Strain Behavior

Study of Contact Behavior in the Pre-squeeze Stage of

Stress Analysis Lecture 4 ME 276 Spring Dr./ Ahmed Mohamed Nagib Elmekawy

Riccardo M.G. Ferrari, PhD Danieli Automation S.p.A. (Buttrio, Italy)

FULL SCALE TESTS AND STRUCTURAL EVALUATION OF SOIL-STEEL FLEXIBLE CULVERTS FOR HIGH-SPEED RAILWAYS

ME411 Engineering Measurement & Instrumentation. Winter 2017 Lecture 9

MARKS DISTRIBUTION AS PER CHAPTER (QUESTION ASKED IN GTU EXAM) Name Of Chapter. Applications of. Friction. Centroid & Moment.

Analysis algorithm for surface crack detection by thermography with UV light excitation

Study of Rotational Column with Plastic Hinge

Advanced Structural Analysis EGF Section Properties and Bending

The 5rd International Conference on. COMEC OCTOBER 2013, Brasov, Romania

Peltier Application Note

Strain Measurement MEASUREMENT EXPERIMENT

ARTICLE IN PRESS. Mechanical Systems and Signal Processing

Introduction to Continuous Systems. Continuous Systems. Strings, Torsional Rods and Beams.

Compressive Residual Stress Optimization in Laser Peening of a Curved Geometry

MECHANICS OF MATERIALS

Transcription:

Thermoelastic study of an aluminum component using an automatic correction procedure of data acquired in non-adiabatic conditions More info about this article: http://www.ndt.net/?id=20747 Abstract by A. Gallotti, S. Desiderati and A. Salerno Dipartimento di Energia, Politecnico di Milano, via Lambruschini 4, 20156 Milano, Italy antonio.salerno@polimi.it Quantitative results in Thermoelastic Stress Analysis (TSA) are often affected by a systematic error, when the test is not performed in adiabatic conditions. A correction procedure can be implemented in order to recover the adiabatic temperature, i.e. the temperature distribution that would have been present if adiabatic conditions had been reached. Such correction procedure however depends on the right assumption on the kind of stress distribution, e.g. linear, parabolic or cubic. The most adequate stress distribution can be chosen automatically by performing the thermoelastic test at different frequencies. This technique allowed obtaining quantitative TSA results on a helicopter aluminum component. 1. Introduction When a solid is subject to a sufficiently fast deformation and volume variation, produced by applying a load, it undergoes an adiabatic transformation with a consequent temperature variation. Thermoelastic Stress Analysis (TSA) is capable of linking such temperature variation to the variation of the first stress invariant in case of adiabatic conditions [1]. TSA is normally performed by applying a load, whose intensity is sinusoidally modulated in time. The result of a TSA measurement is one amplitude image, in which every point represents the amplitude of the modulated temperature, and one phase image, in which every point represents the phase shift of the modulated temperature with respect to the modulated load applied. TSA tests on real metallic components seldom reach adiabatic conditions, because the load cannot be applied at a sufficiently high frequency, so as to prevent the heat diffusion from points assuming different temperatures during the modulated application of the load. This produces an attenuation of the temperature peaks and a systematic error in TSA results. When adiabatic conditions are reached, the temperature variation is in phase or antiphase with the load applied, i.e. ϕ = 0 or 180 depending on the fact that a region can be under traction or compression. When adiabatic conditions are not reached, the temperature amplitude of points having high stress concentrations undergo a temperature attenuation. Furthermore, in non-adiabatic conditions the phase shift between the load applied and the modulated surface temperature is different from 0 or 180 and it varies with the frequency, approaching these values when the modulation frequency of the load increases. The analytical solution of the direct problem allowed to discover that the function linking the attenuation to the phase shift (correction function) only depends on the kind of stress distribution, for example linear, quadratic or cubic [2]. Based on the geometry, the constraints and the load applied, an operator can make an assumption on the kind of stress distribution and choose the more appropriate correction function. For instance, for a cantilever beam fixed at one end and with a force normal to its axis applied to the other end, the stress distribution is linear, while near a hole in a beam subject to an axial load the stress distribution is more similar to a parabolic one. Starting from the phase shift, the correction function gives the attenuation. Once the attenuation is known, from the measured temperature amplitude ΔT the adiabatic temperature amplitude ΔT ad can be reckoned, which in turn is liked to the amplitude of the first stress invariant Δσ, determinable from the temperature through the thermoelastic equations. Such a correction procedure was applied on several real components and gave results in good agreement with experimental data acquired by strain gauges, when available [3, 4]. However, applying the same correction function to every point of a component surface may be wrong. For instance, let us consider a cantilever beam with a hole in the center subject to a bending moment. Close to the hole edge the stress distribution could be approximated by a parabolic function, while far from the hole the dominant stress distribution is linear. Applying a parabolic or a linear correction on the whole image, would inevitably lead to a wrong correction on a portion of the image. For some complicated geometries or for components on which more than one load is applied, choosing the more appropriate correction function could be not straightforward. 2. The thermoelastic effect The thermoelastic effect was firstly studied by Kelvin[5] in 1853, but the basic equation relating the temperature variation δt to the first stress invariant variation δσ = σ I + σ II + σ III was introduced by Darken and Curry[6] in 1953: 714

δt T 0 = K 0 δσ (1) where T 0 is the average temperature (normally the ambient temperature) and K 0, named thermoelastic constant, is a material parameter comprising the coefficient of linear thermal expansion λ, the mass density ρ and the specific heat at constant pressure c p: K 0 = λ ρc p (2) Applying equ. (1) to the Fourier equation, it is easy to obtain the expression of the thermoelastic heat source: q = ρc v K 0 T 0 σ t (3) From this basic theory it is evident that only stress variations can give a thermoelastic heat source. A sinusoidally modulated load producing a sinusoidally modulated stress distribution is then normally applied to a component in TSA tests. 3. Automatic correction Given a modulated stress distribution in a component, thermoelastic heat sources are distributed like the stress. Heat is then diffused in the sample if adiabatic conditions are not reached. The direct heat conduction problem can be easily solved analytically or numerically, using the Fourier equation, to obtain the temperature variation at different frequencies and for different stress distributions. For every stress distribution a correction function can be obtained linking the phase shift to the temperature attenuation: 1 ΔT ΔT ad = f σ (Δϕ) (4) Where the first member is the temperature attenuation and f σ is the correction function. From equ. (4) the adiabatic temperature variation can be readily obtained: ΔT ad = ΔT 1 f σ (Δϕ) (5) If a TSA test can for example be performed at three different frequencies, starting from three different phase shifts Δϕ i (i=1, 2, 3), three different adiabatic temperature variations ΔT ad, i can be evaluated using the same correction function f σ The idea at the base of the automatic correction [7] is that if the real stress distribution corresponds to the stress distribution for which the direct Fourier problem has been solved, and the correspondent correction function determined, the reckoned adiabatic temperature variation ΔT ad should be correct and independent from the frequency. So for instance if the real stress distribution is linear, a correction function obtained for a linear stress distribution should give a correct value for the adiabatic temperature variation ΔT ad regardless of the modulation frequency. Since in reality the stress distribution for which the correction function has been determined does not perfectly correspond to the real stress distribution, performing N tests at N different frequencies, will give N different values of the adiabatic temperature variation ΔT ad. An average value: 715

ΔT ad ave = 1 N N i=1 ΔT i 1 f σ (Δϕ i ) (6) and a standard deviation std = 1 N 1 N i=1 ΔT i 1 f σ (Δϕ i ) ΔT ad ave 2 (7) can therefore be obtained for a given correction function f σ. A correction function f σ corresponding to the real stress distribution would give always the same result, regardless of the frequency, and a zero value for the standard deviation (std=0). Many stress distributions can be considered and the same number of correction functions can be obtained analytically or numerically. Among them, a computer program can automatically select the correction function having the minimum value for the standard deviation, i.e. the correction function obtained starting from a stress distribution more closely corresponding to the real one. The process is replicated for the available correction functions and for every pixel, so that for every pixel of the TSA amplitude image the best correction function is chosen. The real correction of the amplitude TSA image is then performed pixel by pixel starting from the amplitude TSA image obtained at the highest available frequency, which, being closer to adiabatic conditions, is affected by the lower attenuation error. 4. Component and experimental conditions The TSA study was performed on a helicopter metallic component comprising several parts in different aluminum alloys (2024, 7075, 7475) riveted together. The component was originally covered by a primer coating, which is always applied to aeronautic components to protect their surface. Such a primer coating was sufficiently thick to disturb the TSA measurement, introducing an additional attenuation and a phase shift also at low frequencies. The primer was then removed from the surface in the region of the measurement, to allow better conditions for obtaining quantitative thermoelastic results. The area of the TSA measurement was then spray painted in black so as to create a high emissivity paint coating, sufficiently thin not to disturb the thermoelastic measurements and avoid reflections from the environment. The component had a platform on which an attachment was fixed with four bolts. A single hydraulic jack was acting on the component pulling the attachment.the platform was creating a shoulder, which locally complicated the shape and the stress distribution in the component. Tests were performed using two different loads values at different frequencies according to table 1. Table 1. Loads applied for the TSA test Load Static [kg] Dynamic [kg] Max [kg] Min [kg] Freq. [Hz] A 850 800 1650 50 1-3-6 B 1250 1200 2450 50 1-3 Load A had a dynamic component of 800 Kg and it was applied at a maximum frequency of 6 Hz. Load B had a dynamic component of 1200 Kg, but the maximum possible frequency was only 3 Hz. Fig. 1 shows the area of interest near the attachment of the jack. One end of the attachment is visible and the shoulder formed by the platform on which the attachment was positioned. 716

Platform Battuta and shoulder Attacco attachment martinetto Fig. 1. Area of the attachment of the jack presenting a platform and a shoulder. 5. TSA results and comparison with the results of a strain gauge rosette Fig. 2 shows the amplitude TSA image obtained with load A (800 kg dynamic) at 6 Hz. Fig. 3 shows the first stress invariant according to the TSA measurement along line L of Fig. 2 applying load A at three different frequencies: 1, 3 and 6 Hz. The non achievement of adiabatic conditions is evident from the rising of TSA stress with frequency. At 1 Hz the maximum value is 15 MPa with a strong attenuation. At 6 Hz the maximum value is approximately 27 MPa, but adiabatic conditions are not yet reached and an attenuation is still present. Fig. 2. TSA result obtained with load A at 6 Hz Fig. 3. The rising of the strain with frequency, evaluated using the thermoelastic relations, is a sign of non-adiabatic conditions Fig. 4 shows the result of the automatic correction applied on the TSA amplitude image obtained with load A at 6 Hz. The maximum value reaches 36 MPa with a 33.33% increment in relation to the non corrected value of 27 MPa. Comparing Fig. 2 and Fig. 4 and taking as a reference 20 MPa (yellow colour on both images), one can easily observe the enlargement of the area stressed above this value. The diagram of the stress along lines 1, 2 and 3 is shown in figures 5 to 7. A steep stress gradient is present in the region. One of the advantages of TSA is that it produces a map of the stress distribution on the whole surface, easily allowing to spot the point of maximum stress concentration. 717

Fig. 4. Corrected stress values obtained applying the automatic correction on TSA amplitude images acquired with load A at 6 Hz. Fig. 2. Stress values along line 1of Fig. 4: non corrected (lower green line); corrected automatically (upper blue line); median filter of the corrected results (red line) Fig. 3. Strain values along line 2 of Fig. 4: non corrected (lower green line); corrected automatically (upper blue line); median filter of the corrected results (red line) Fig. 4. Strain values along line 3 of Fig. 4: non corrected (lower green line); corrected automatically (upper blue line); median filter of the corrected results (red line) 718

A strain gauge rosette was placed in a position near the attachment according to Fig. 8. The position of the strain gauge rosette did not correspond precisely to the observed peak of the first stress invariant. Fig. 5. Position of the strain gauge rosette on the component near the attachment. While TSA can reveal the first stress invariant on the entire surface, a strain gauge rosette can measure the single directional components of the strain, but in a one point only. A further advantage of TSA is that it can read the first stress invariant with a very high spatial resolution, virtually limited only by the wavelength of the IR radiation used and by the quality of the optics and of the IR camera. On the contrary the result obtained by a strain gauge is the average deformation of an area equal to its surface, i.e. some millimeters. TSA reads the peak to peak value of the first stress invariant, therefore, given a dynamic load of 800 Kg, the result must be compared with that of a strain gauge, when the component is statically loaded with 1600 Kg. In this condition the first stress invariant measured by the strain gauge rosette was 28.93 MPa. The precise position of the strain gauge rosette in relation to the stress distribution shown by the TSA test is difficult to determine, but the strain gauge rosette was placed in an area where the TSA gave a result comprised between 25 and 30 MPa. 6. Conclusions TSA allows for the fast and contactless measurement of the first stress invariant distribution on a component under load. Real components cannot be loaded at high modulation frequencies and adiabatic conditions are almost never reached. An automatic correction procedure was used to recover the adiabatic temperature starting from data acquired in non-adiabatic conditions. The adiabatic temperature was then converted into the first stress invariant (MPa) according to the thermoelastic equations. The results showed a local high stress concentration, whose maximum value reached 36 MPa. A strain gauge rosette was placed in a region where the TSA gave a result comprised between 25 and 30 MPa. The first stress invariant evaluated using the strain gauge rosette was 28.93 MPa. REFERENCES [1] Harwood N. and Cummings W. M., Thermoelastic Stress Analysis, IOP Publishing (Adam Hilger), Bristol, UK, 1991. [2] Salerno A. and Desiderati S. Procedure proposal for the correction of nonadiabatic thermoelastic stress analysis results, Review of Scientific Instruments, Vol. 75, N.2, pp. 507-514, 2004. [3] D. Colombo, S. Desiderati, M. Giglio, A. Salerno, TSA-FEM comparative analysis of a helicopter component under multiaxial load, Strain, Vol. 43, pp. 311-318, 2007 [4] S. Desiderati and A. Salerno, Strain Gage Identification of the Correction Procedure for Quantitative Thermoelastic Stress Analysis under Non-adiabatic Conditions, Materials Evaluation, pp. 855-861, 2015 [5] Thomson W., On the Dynamic Theory of Heat, trans. Royal Society, Vol. 20, pp. 261, 1853 [6] Darken L. and Curry R., Physical Chemistry of Metals, McGraw-Hill, London, 1953 [7] Gallotti A., Salerno A., Automatic procedure for the correction of thermoelastic stress analysis data acquired in non-adiabatic conditions, Review of Scientific Instruments, Vol. 76, N. 12, pp. 124903-124903-7, 2005 719