Supplementary table I. Table of contact angles of the different solutions on the surfaces used here. Supplementary Notes

Similar documents
DLVO interaction between the spheres

Lecture 7 Contact angle phenomena and wetting

Supplementary Figure 1 Surface tension of polyelectrolyte solutions. Experimentally measured values of surface tension of the solutions that were

CPGAN # 006. The Basics of Filament Stretching Rheometry

arxiv: v2 [physics.flu-dyn] 24 Oct 2013

Supplementary information

Supplementary Information on Thermally Enhanced Self-Propelled Droplet Motion on Gradient Surfaces

spreading of drops on soft surfaces

Instabilities in Thin Polymer Films: From Pattern Formation to Rupture

Dynamic Self Assembly of Magnetic Colloids

Surface and Interfacial Tensions. Lecture 1

Instability and Patterning of Thin Polymer Films Prof. R. Mukherjee Department Of Chemical Engineering Indian Institute Of Technology, Kharagpur

Fabrication of ordered array at a nanoscopic level: context

contact line dynamics

Supplementary material to On the rheology of pendular gels and morphological developments in paste- like ternary systems based on capillary attraction

A Technique for Characterizing Complex Polymer Solutions in Extensional Flows. Gavin Braithwaite Stephen Spiegelberg

Module 3: "Thin Film Hydrodynamics" Lecture 12: "" The Lecture Contains: Linear Stability Analysis. Some well known instabilities. Objectives_template

Turbulent Mixing of Passive Tracers on Small Scales in a Channel Flow

Lecture 2. Fundamentals and Theories of Self-Assembly

Supplementary Information. SI Text 1: Derivation and assumptions of the effective temperature model

Imaging Methods: Breath Patterns

COMPARISON OF WETTABILITY AND CAPILLARY EFFECT EVALUATED BY DIFFERENT CHARACTERIZING METHODS

On the effects of Non-Newtonian fluids above the ribbing instability

Interfacial Instabilities in a Microfluidic Hele-Shaw Cell: Supplemental

Supplementary Figure 1: Micromechanical cleavage of graphene on oxygen plasma treated Si/SiO2. Supplementary Figure 2: Comparison of hbn yield.

Single Molecule Electrochemistry on a Porous Silica-Coated Electrode

Nature Protocols: doi: /nprot Supplementary Figure 1

emulsions, and foams March 21 22, 2009

We may have a general idea that a solid is hard and a fluid is soft. This is not satisfactory from

SUPPLEMENTARY INFORMATION

Drop formation in non-newtonian fluids

CHAPTER 1 Fluids and their Properties

Toward Clean Suspended CVD Graphene

Fluid Mechanics Introduction

A Photonic Crystal Laser from Solution Based. Organo-Lead Iodide Perovskite Thin Films

NANOSCIENCE: TECHNOLOGY AND ADVANCED MATERIALS

A-level PHYSICS (7408/3BD)

Bursting Drops in Solids Caused by High Voltages

SYNTHESIS OF INORGANIC MATERIALS AND NANOMATERIALS. Pr. Charles Kappenstein LACCO, Laboratoire de Catalyse en Chimie Organique, Poitiers, France

Physics and Chemistry of Interfaces

Microfluidics 2 Surface tension, contact angle, capillary flow

A. Optimizing the growth conditions of large-scale graphene films

Instability & Patterning of Thin Polymer Films Prof. R. Mukherjee Department of Chemical Engineering Indian Institute Of Technology, Kharagpur

Supplementary Methods

Intensity (a.u.) Intensity (a.u.) Raman Shift (cm -1 ) Oxygen plasma. 6 cm. 9 cm. 1mm. Single-layer graphene sheet. 10mm. 14 cm

Threshold of ribbing instability with Non-Newtonian fluids

ECE185 LIQUID CRYSTAL DISPLAYS

Supplementary Information

Supplementary Methods A. Sample fabrication

Gold-poly(N-isopropylacrylamide) core-shell colloids with homogeneous density profiles: A small angle scattering study

Dynamics of Transient Liquid Injection:

ISCST shall not be responsible for statements or opinions contained in papers or printed in its publications.

Modular Microscope Accessory

Hydrodynamics of wetting phenomena. Jacco Snoeijer PHYSICS OF FLUIDS

Reaction at the Interfaces

Chapter 10. Intermolecular Forces II Liquids and Phase Diagrams

Misting in Forward Roll Coating: Structure Property Processing Relationships

P = 1 3 (σ xx + σ yy + σ zz ) = F A. It is created by the bombardment of the surface by molecules of fluid.

Supporting Information. Even Hard Sphere Colloidal Suspensions Display. Fickian yet Non-Gaussian Diffusion

DESIGN OF ATOMIZERS AND BURNERS FOR COAL-WATER SLURRY COMBUSTION. Grant Number: DE-FG22-95PC95105 Progress Report for Period 1/1/97-3/31/97

Temperature ( o C)

Visualize and Measure Nanoparticle Size and Concentration

On the Landau-Levich Transition

Particle removal in linear shear flow: model prediction and experimental validation

[Supplementary Figures]

Supporting Information

Supplementary Figure 1 Experimental setup for crystal growth. Schematic drawing of the experimental setup for C 8 -BTBT crystal growth.

Lecture 7: Rheology and milli microfluidic

Supplementary Information. In colloidal drop drying processes, multi-ring depositions are formed due to the stick-slip

PhysicsAndMathsTutor.com 1

Instabilities in the Flow of Thin Liquid Films

COMPLEX FLOW OF NANOCONFINED POLYMERS

Ultrafast water harvesting and transport in hierarchical microchannels

Full-color Subwavelength Printing with Gapplasmonic

Liquid State S.Y.B.Sc Characteristics of the liquid state Properties exhibited by liquid state.

Bioassay on a Robust and Stretchable Extreme Wetting. Substrate through Vacuum-Based Droplet Manipulation

Plasma spectroscopy when there is magnetic reconnection associated with Rayleigh-Taylor instability in the Caltech spheromak jet experiment

Concentrated suspensions under flow in microfluidic channel and migration effect

Mohamed Daoud Claudine E.Williams Editors. Soft Matter Physics. With 177 Figures, 16 of them in colour

Line Tension Effect upon Static Wetting

The Flow of Thin Liquid Layers on Circular Cylinders

How DLS Works: Interference of Light

Optical Microscopy Study of Topological Insulators Using Ellipsometry

Questions on Electric Fields

Bincy Jose, Colm T. Mallon, Robert J. Forster & Tia E. Keyes School of Chemical Sciences, Dublin City University, Dublin 9, Ireland

PHY 192 Optical Activity 1

Thickness and Shape of Films Driven by a Marangoni Flow

Visualization of polymer relaxation in viscoelastic turbulent micro-channel flow

Quantitative dynamic footprinting microscopy reveals mechanisms of neutrophil rolling

8.6 Drag Forces in Fluids

Optical properties of spherical and anisotropic gold shell colloids

The Capillary Breakup Extensional Rheometer (CABER )

Self-assembled and intercalated film of reduced. graphene oxide for a novel vacuum pressure sensor

Effect of Viscosity on the Breakup Length of Liquid Sheets Formed by Splash Plate Nozzles. University of Toronto, Toronto, ON M5S 3G8

Effects of Size, Humidity, and Aging on Particle Removal

Selective Manipulation of Molecules by Electrostatic Force and Detection of Single Molecules in Aqueous Solution

Supplementary information for

contact line dynamics

J09M.1 - Coupled Pendula

Interfacial hoop stress and viscoelastic free surface flow instability. Michael D. Graham University of Wisconsin-Madison

Transcription:

1 Supplementary Figure 1. Sketch of the experimental setup (not to scale) : it consists of a thin mylar sheet (0, 02 4 3cm 3 ) held fixed vertically. The spacing y 0 between the glass plate and the upper end of the scraper can be adjusted with a translation stage with 10µm precision. The polymer solution is deposited on a hydrophobic glass substrate with dimensions 6 15cm 2 and 2 mm thickness. The substrate is then translated in the z direction with a precision motorized translation stage (Marzhauser Wetzlar SCAN IM 130 100) capable of moving at stable speeds ranging from 0.04mm/s to 10mm/s. This set up is mounted on an inverted microscope stage. Supplementary Figure 2. Rheology mesurements for polyacrilamide (PAM) and polyethylene oxide (PEO) solutions used at different molecular weights and concentrations.

2 Supplementary Figure 3. Measurement of contact angles on the different glass substrates prepared (from left to right : plasma cleaned, bare and silanized glass) using photographs of a small drop of polymer solution (PAM). Supplementary Figure 4. Mean distance h between blade and glass surface versus velocity V. This distance is obtained by plotting the position of the bottom side of the blade with respect to the substrate (photograph and inset). Supplementary Figure 5. Spatio-temporal photographs of the receding contact line for Glycerine (99.9%) for two different translation speeds. Left: Below the transition to film formation v = 40µm/s. Right: Above the threshold to the transition v = 100µm/s. Note that dewetting holes can emerge at later times in the deposited film.

3 Supplementary Figure 6. Surface covered by Glycerine normalised by the surface explored by the flexible scraper during the coating. The jump from low surface coverage ratio to 1 determines the velocity threshold V C to film formation (represented by the grey area). Supplementary Figure 7. Pinch-off experiments of PAM and PEO solutions. The radius of the fluid neck during pinch off is plotted versus time. The later stages can be approximated by an exponential thinning law giving a constant extension rate in the neck. The characteristic times τ of the polymer solutions is obtained from the thinning dynamics and is proportional to the inverse of this stretching rate. The photograph illustrates the detachment of a drop falling from a capillary; note the formation of a long filament to this capillary. Supplementary Figure 8. Two cases of particle tracking in fingers for PAM (Upper) and PEO (Lower) solutions at the same velocity v = 100µm.s 1. The stretching rate is obtained from dv z /dz.

4 Supplementary table I. Table of contact angles of the different solutions on the surfaces used here. Solution Bare Silanized Angle ( ) Angle ( ) Glycerine 99.9% 38 90 PEO 4M 10,000 ppm 20 92 15,000 ppm 20 90 PAM 10M 10,000ppm 20 107 PAM 18M 3,000ppm 22 102 10,000ppm 18 107 Supplementary Notes Supplementary Note 1. Coating. Experiments carried out using non hydrophobic substrates (plasma cleaned glass or bare glass for which the contact angles are respectively 10 and 45, the solution forms a homogeneous layer on the substrate for most velocities used. It is known that in dip coating experiments, a transition to a dynamic wetting state giving rise to homogeneous film formation occurs for velocities above a certain threshold. In general, a capillary number Ca=ηV/γ is defined where η is the viscosity of the solution, V is the velocity of the substrate, and γ is the liquid surface tension. The transition to film formation and therefore wetting occurs for capillary numbers which depend on the contact angle, the smaller the contact angle, the smaller the critical capillary number for the wetting transition. Since the viscosity of the solutions used here depends on the shear rate, the capillary number is redefined as Ca=η( γ)v/γ.. To estimate the shear rate in these experiments, the distance h between scraper and substrate has to be known. Our visualization experiments during the coating process indicate that this distance is of the order of 100µm with a small decrease versus velocity (See Supplementary Figure 4). In this case, we neglect shape of the velocity profile and approximate the shear rate γ. = V/h. By using this estimate the capillary number varies between 0.01 and 0.1 which is higher than the critical capillary number for the contact angles considered and for which film formation is expected as observed. In the case where the glass substrate has not been treated with OTS (i.e, the contact angles of 45 and 10 ) the fingering instability on the receding contact line is therefore not observed in the translation speed range studied, and the coating of the polymer solution always occurs on the glass plate (the value of the critical capillary number that describes the transition for a partially wetting fluid to form a homogeneous film on a surface is near Ca 10 2. In our case where the viscosity at low shear rates is near η = 50P a.s, the transition to film formation should be obtained for a velocity of v = 0, 01mm/s (lower than those allowed by our translation stage) indicating that forced wetting is always present. Experiments using Glycerine confirm this conclusion since coating and film formation occurs for speeds as low as 40µm/s (See the spatio-temporal photograph of the receding contact line of Glycerine at v = 40µm/sand 100µm/s in Supplementary Figure 5) corresponding to a critical capillary Ca c = 1, 56.10 3, in agreement with the prediction of this value given by the Cox s model [1] : Ca c = θ3 e 9ln L l (1) With L estimated as the capillary length, l as the molecular size (nm) and θ e as the static contact angle (see supplementary table TI) In order to estimate Ca c for Glycerine, we used a simple criterion, consisting of the evaluation of the surface covered by the fluid on the substrate S covered during the coating. If the ratio S covered /S total is roughly close to 1, the dewetting speed is lower than the speed of the contact line leading to the total coverage of the substrate (Cf. Supplementary Figure 6). Otherwise, the fluid does not wet the surface and the velocity is below the transition of total coverage. The jump in this ratio S covered /S total allows us to determine the critical velocity V C of transition from partial wetting to total wetting on the substrate. However, for equilibrium contact angles greater than 90, the contact line is unstable and well defined fingers emerge as explained in the main text and as will be described in the next section. Supplementary Note 2. Determination of the stretching rate in the filaments. The strong dependence of the number of fingers N deposited on the substrate with the velocity is clearly visible in Fig. 1 of the main text. In

Figure 1 (c) of the main text, we reported the mean wavelength of fingers λ (estimated as W/N where W is the width of the blade or the width of the visualization window) deposited on the substrate versus the translation speed. The error bars reflect the variability of the number of fingers (typically on the size of the observation field) for the different videos recorded. We also studied the shape of the fingers as we represented in Figure 2 (main text). In the inset of Figure 2b, we plot the shape of the fingers near the contact line for different spreading velocities (from 50µm/s to 10mm/s) and show that the faster the substrate velocity, the wider the fingers. We analyzed the functional shape of these fingers by normalizing the profiles using two characteristic spatial scales (Cf. Fig. 3(b) & 3(c)): a characteristic width l and a characteristic length L. This is shown in Fig.3(b) where the normalized shapes of the fingers do not depend on the translation velocity. Moreover, the finger width l and the finger length L found here increase with the translation speed. We represented in Fig. 3 (c) the dependence of l and L versus the translation speed V, both quantities vary roughly linearly with the translation velocity. The dependence of the length on the velocity allows to define a characteristic stretching rate V/L. This rate is independent of the velocity V. This property can be rendered more systematic by measuring the mean stretching rate along the fingers by using particle tracking experiments. In order to carry out these measurements, we seeded the solutions with small particles of 1 or 6 µm in diameter (PMMA or Polystyrene fluorescent particles from Polysciences and Molecular Probes) and tracked their trajectories from video imaging. Supplementary Figure 8 below shows the velocity along the center line of the filaments. In general this velocity is small near the meniscus and then as the particles enter the filament, this velocity increases roughly linearly with distance traveled to reach the translation velocity of the plate. Far away from the meniscus, the filaments are simply translated at the same velocity as the plate on which they are deposited. As mentioned in the main text, the mean stretching rate obtained from dv z /dz in the centerline of the filaments remains conserved as the velocity changes. Apparently, the filaments all have similar stretching rates for the same solution. This stretching rate changes only when the solution changes. This stretching rate turns out to be determined by the characteristic time of the solutions used. In order to obtain this time scale and as suggested by Hinch, McKinley and others [2], filament stretching experiments or droplet pinch off experiments can be used. Here the thinning rate of the liquid necks connecting the drops to the capillary is controlled by the characteristic time of the solution making this technique useful for its determination. Supplementary Figure 7 below shows the thinning of fluid necks for the different solutions used. Note that the characteristic time scale for the thinning of these necks which follows an exponential law versus time can be obtained by fitting an exponential decay law. From the characteristic time of thinning necks, one obtaines dr dt the stretching rate in the neck ε = 2 R where R is the radius of the liquid neck and t is time. The value of ε is related to the characteristic time of the polymer solutions τ by ε = 3/τ. The value of ε obtained from this measurement is compared to that obtained from the velocity in the centerline of the filaments in the main text (Figure 3 (f)). The two values agree well with each other. The fingers select a constant stretching rate ε fixing the value of the characteristic length L through ε = V/L. Because the stretching rate remains constant versus V, the length L increases with V as observed. Since the width of the fingers also increases with L the separation between fingers, and therefore the wavelength of the patterns must increase otherwise the fingers merge by coalescence. These fingers have a curious dynamical behavior. Two fingers close to each other may merge and form a single finger (see Figure 3 (a) in the main text). This coalescence gives rise to a defect on the linear pattern of lines on the plate. Further and when two fingers drift apart from each other, a third finger may emerge in the spacing between the two initial fingers. We believe this is the mechanism to maintain the spatial wavelength constant: fingers attract and merge and fingers emerge in empty space. Supplementary Note 3. Details concerning the applications. These patterns have been used for different deposition strategies. Figure 4 shows that if particles (fluorescent from Molecular Probes and not from Polysciences) are embedded into the fluid they may be deposited in a linear pattern with a variable spacing. Further, and if the moving plate is translated in the transverse direction along with its longitudinal translation, wavy and triangular patterns can be created. Larger particles can also be deposited as single isolated spheres or in higher concentrations as seen in the photographs of Fig.4. Another possibility is to use the tunability of the obtained structure both in terms of wavelength and in terms of dimensions to filter different sized particles when they are mixed together in a solution. The supplementary video SV04 illustrates this possibility. This video was recorded in bright field and in fluorescent microscopy and shows an example of the coating of a solution with particles of 1 & 6µm in diameter. Particles of 1µm appear bright as they are fluorescent. The small particles are seen to enter the filaments while the larger ones are blocked near the meniscus. Another observation was made using additional fluorescent DNA molecules added to the solutions. The DNA T4 GT7 (from Nippon Gene) are made fluorescent thanks to the intercalator POPO3 (from Molecular probes). It was added in the proportion of 1 for 5 base pairs. The DNA and polymer solutions are made with TRIS EDTA buffer solution (from Fluka) at ph 8. The total length of fully stretched DNA T4 with fluorescent molecules is estimated as 72µm. Here, the formation of the filaments stretches the DNA molecules which are then deposited on the substrate. 5

This stretching can be quite important as the length of the molecule shown in Fig. 4 (d and e) is almost 50% of the contour length of the molecule. Stretching deformable objects or aligning anisotropic entities such as carbon nanotubes in these filaments with variable spacing opens the possibility of making anisotropic structures with tunable properties useful for different uses such as screening (biological molecules) or electrical and optical coatings. 6 Supplementary References [1] Cox R. G., Journal of Fluid Mechanics, Volume 168, July 1986, pp 169-194. [2] Clasen C., Eggers J., Fontelos M. A., Li J. And McKinley G. H. Fluid Mech. (2006), vol. 556, pp. 283âe 308.