HOMOGENEOUS ELECTRORHEOLOGICAL FLUIDS APPLIED TO VIBRATION CONTROL

Similar documents
MECHANICAL CHARACTERISTICS OF STARCH BASED ELECTRORHEOLOGICAL FLUIDS

Lecture 20. Measuring Pressure and Temperature (Chapter 9) Measuring Pressure Measuring Temperature MECH 373. Instrumentation and Measurements

Chapter 31: Principles of Active Vibration Control: Electrorheological fluids

10 Measurement of Acceleration, Vibration and Shock Transducers

Active elastomer components based on dielectric elastomers

Transactions on the Built Environment vol 22, 1996 WIT Press, ISSN

The secondary winding have equal no. of turns. The secondary windings are placed identically on either side of the primary winding.

Dynamic Stability of Laminated Composite Plates with an External Smart Damper

Piezoelectric Resonators ME 2082

Module I Module I: traditional test instrumentation and acquisition systems. Prof. Ramat, Stefano

MEMS INERTIAL POWER GENERATORS FOR BIOMEDICAL APPLICATIONS

DEVELOPMENT OF DROP WEIGHT IMPACT TEST MACHINE

CHAPTER 4 DESIGN AND ANALYSIS OF CANTILEVER BEAM ELECTROSTATIC ACTUATORS

Apparent stress-strain relationships in experimental equipment where magnetorheological fluids operate under compression mode

Energy balance in self-powered MR damper-based vibration reduction system

Vibration Measurements Vibration Instrumentation. MCE371: Vibrations. Prof. Richter. Department of Mechanical Engineering. Handout 11 Fall 2011

Effect of Liquid Viscosity on Sloshing in A Rectangular Tank

Francisco Paulo Lépore Neto. Marcelo Braga dos Santos. Introduction 1. Nomenclature. Experimental Apparatus and Formulation

VIBRATION ENERGY FLOW IN WELDED CONNECTION OF PLATES. 1. Introduction

APPLICATION OF CFD TO MODELING OF SQUEEZE MODE MAGNETORHEOLOGICAL DAMPERS

MOOC QP Set 2 Principles of Vibration Control

Unit 57: Mechatronic System

MODELLING AND TESTING OF AN ERF VIBRATION DAMPER FOR LIGHT ROTORS WITH LARGE AMPLITUDES

Basic Principle of Strain Gauge Accelerometer. Description of Strain Gauge Accelerometer

The performance of a magnetorheological fluid in squeeze mode

Control Engineering BDA30703

INTRODUCTION TO PIEZO TRANSDUCERS

Lecture 19. Measurement of Solid-Mechanical Quantities (Chapter 8) Measuring Strain Measuring Displacement Measuring Linear Velocity

Physical and Biological Properties of Agricultural Products Acoustic, Electrical and Optical Properties and Biochemical Property

DAMPING CONTROL OF A PZT MULTILAYER VIBRATION USING NEGATIVE IMPEDANCE CIRCUIT

DSC HW 3: Assigned 6/25/11, Due 7/2/12 Page 1

VIBRATION RESPONSE OF AN ELECTRIC GENERATOR

Study and design of a composite acoustic sensor to characterize an heterogeneous media presenting a complex matrix

Francisco Paulo Lépore Neto. Marcelo Braga dos Santos. Introduction 1. Nomenclature. Experimental Apparatus and Formulation

DESIGN OF A HIGH-EFFICIENCY MAGNETORHEOLOGICAL VALVE

Dynamics of structures

APPLICATIONS OF VIBRATION TRANSDUCERS

PIEZOELECTRIC MATERIALS USED FOR PORTABLE

Stability for Bridge Cable and Cable-Deck Interaction. Dr. Maria Rosaria Marsico D.J. Wagg

2. For a S.H.O. determine, (a) the total energy (E), the kinetic and potential energies. of half amplitude:

Estimation of damping capacity of rubber vibration isolators under harmonic excitation

Non-linear Modal Behaviour in Cantilever Beam Structures

DROP-WEIGHT SYSTEM FOR DYNAMIC PRESSURE CALIBRATION

APPLICATION OF DENSITOMETERS TO LIQUID MEASUREMENT Class #

STRAIN GAUGES YEDITEPE UNIVERSITY DEPARTMENT OF MECHANICAL ENGINEERING

Vibration modelling of machine tool structures

Optimal Location of an Active Segment of Magnetorheological Fluid Layer in a Sandwich Plate

Dynamic Tests on Ring Shear Apparatus

I INTRODUCTION II THEORY

US06CPHY06 Instrumentation and Sensors UNIT 2 Part 2 Pressure Measurements

Comparison between the visco-elastic dampers And Magnetorheological dampers and study the Effect of temperature on the damping properties

Mechanical properties of polymers: an overview. Suryasarathi Bose Dept. of Materials Engineering, IISc, Bangalore

Chapter 3. Experimentation and Data Acquisition

On Non-Ideal Simple Portal Frame Structural Model: Experimental Results Under A Non-Ideal Excitation

INVESTIGATION OF IMPACT HAMMER CALIBRATIONS

CHAPTER 6 FRICTION AND WEAR ANALYSIS FOR BUSHING

Dynamic stiffness compensation with active aerostatic thrust bearings

A new cantilever beam-rigid-body MEMS gyroscope: mathematical model and linear dynamics

DEVELOPMENT OF MEASUREMENT STANDARD FOR DYNAMIC PRESSURE AT MIKES

Vibration characteristics of MR cantilever sandwich beams: experimental study

Alireza Mousavi Brunel University

Chapter 7 Vibration Measurement and Applications

STATIC AND DYNAMIC ANALYSIS OF A BISTABLE PLATE FOR APPLICATION IN MORPHING STRUCTURES

The sound generated by a transverse impact of a ball on a circular

666. Controllable vibro-protective system for the driver seat of a multi-axis vehicle

THE RESPONSE TIME OF A PRESSURE MEASUREMENT SYSTEM WITH A CONNECTING TUBE ABSTRACT

o0, and since the period of vibration of the scale is related to the mass,

Finite Element Analysis of Piezoelectric Cantilever

Response of a Physical Mechanical System

Conventional Paper-I-2011 PART-A

Test 3 Preparation Questions

Investigation of Cryogenic Cooling Systems Activated by Piezoelectric Elements

TORQUE CAPACITY ENHANCEMENT OF A MAGNETORHEOLOGICAL FLUID CLUTCH USING THE SQUEEZE-STRENGTHEN EFFECT

SENSORS AND TRANSDUCERS


A small analog memory based on ferroelectric hysteresis

Damping of materials and members in structures

The student will experimentally determine the parameters to represent the behavior of a damped oscillatory system of one degree of freedom.

A method for matching the eigenfrequencies of longitudinal and torsional vibrations in a hybrid piezoelectric motor

19 th INTERNATIONAL CONGRESS ON ACOUSTICS MADRID, 2-7 SEPTEMBER 2007

8. What is the period of a pendulum consisting of a 6-kg object oscillating on a 4-m string?

LECTURE 12. STEADY-STATE RESPONSE DUE TO ROTATING IMBALANCE

Foundations of Ultraprecision Mechanism Design

CHARACTERIZATION OF PIEZOELECTRIC ACTUATORS USED FOR SRF CAVITIES ACTIVE TUNING AT LOW TEMPERATURE

Resonant Column and Torsional Cyclic Shear System

The ISIS Penning H - SPS and Diagnostic Developments at RAL

Georgia Institute of Technology. Nonlinear Dynamics & Chaos Physics 4267/6268. Faraday Waves. One Dimensional Study

TOPIC E: OSCILLATIONS EXAMPLES SPRING Q1. Find general solutions for the following differential equations:

Exploring the vibration control potential of magneto-sensitive rubber

ScienceDirect. Effect of Heat on the Performance of Novel Energy Harvester by using PZT-5H Transducers

Class XI Physics Syllabus One Paper Three Hours Max Marks: 70

GCSE PHYSICS REVISION LIST

DYNAMIC MODEL OF FULL-SCALE MR DAMPERS FOR CIVIL ENGINEERING APPLICATIONS

Wilberforce Pendulum (One or two weights)

ELECTRONIC SENSORS PREAMBLE. This note gives a brief introduction to sensors. The focus is. on sensor mechanisms. It describes in general terms how

The University of Melbourne Engineering Mechanics

Outline. 4 Mechanical Sensors Introduction General Mechanical properties Piezoresistivity Piezoresistive Sensors Capacitive sensors Applications

Selection of the geometric and materials parameters in piezoelectric sensors level

2.0 Theory. 2.1 Ground Vibration Test

Special edition paper

Transcription:

HOMOGENEOUS ELECTRORHEOLOGICAL FLUIDS APPLIED TO VIBRATION CONTROL A.K. El Wahed Division of Mechanical Engineering & Mechatronics, Faculty of Engineering and Physical Sciences, University of Dundee, Dundee. DD1 4HN. U.K e-mail: a.elwahed@dundee.ac.uk Corresponding author Abstract. The purpose Electrorheological (ER) fluids are capable of providing continuously variable damping forces in response to an electrical stimulus. Many prototype ER dampers, described in the literature, have been based upon exploiting the variable shear properties of ER fluids. Recently, an alternative mode of operation, namely squeeze-flow, has been identified and investigated. Furthermore, most of these investigations have been carried out using various particle-dispersion ER fluids. This paper is concerned with an experimental investigation of the performance of a homogeneous electrorheological (ER) fluid in an oscillatory squeeze-flow. The fluid is sandwiched between two parallel plane circular electrodes, the upper one fixed and the lower one oscillating normal to its plane. Of particular interest is the temporal variation in the force transmitted through the fluid in response to changes in the oscillation frequency and the applied voltage. In addition, the effect of temperature changes on the response of this fluid and the relevance of the work in the application to vibration control are discussed. Keywords: Homogeneous electrorheological fluids, squeeze flow, vibration control 1. Introduction Electrorheological (ER) fluids, which belong to the general class of smart materials, can exhibit a massive and reversible change in their rheological properties such as yield stress, apparent viscosity and other moduli when subjected to an electric field. These fluids have been known since the late 1940s when Winslow (1949) investigated their first potential engineering application. These fluids involve slurries of solid semi-conducting particulates, typically of micrometers in size, in dielectric liquids. The response of these fluids to an applied field is the familiar chaining of the particulates in the field direction and the resulting solidification or increase in the apparent viscosity of the fluids (Block, 1990). Industrial applications of these fluids, during the last two decades, have seen considerable progress involving investigations into prototype and model devices. The majority of these devices have employed ER fluids in simple flow or shear mode of operation. An alternative arrangement, squeeze mode, in which the fluid is subjected to compressive and tensile stresses in a direction parallel to the applied field, has been identified (Stanway, 1992). It was shown that the yield stress in this mode, developed under DC excitation, is greater than that available in shear typically by a factor of ten. This increased fluid strength was systematically investigated by the author and others (see for example a recent investigation by El Wahed, 2003) to exploit the mechanical and electrical properties of ER fluids in squeeze. Furthermore, recent findings of homogeneous (without dispersed particles) ER fluids has prompted further scientific and engineering studies on the ER effect (Inoue, 1995). It was shown that large stresses were measured when this new fluid was subjected to shear loading. The present investigation addresses the determination of the performance of a homogeneous ER fluid in squeeze under various mechanical and electrical conditions. 2. Experimental Arrangement The experimental rig, Fig. 1, consists of a Ling Dynamic Systems electromagnetic shaker (Model No. V450) which is capable of providing vertical oscillatory motion with a maximum amplitude of 19 mm (peak-to-peak) over a frequency range from zero to 7.5 khz. The shaker head is attached rigidly to a Kistler (Model No. 9311A) piezoelectric force link and an earthed brass electrode having a recessed cylindrical cavity of diameter 95 mm which provides the reservoir for the ER fluid. The high voltage (upper) electrode is a circular brass disc of diameter 56 mm, its circumferential edge and rear face surrounded and supported by a PTFE collar. This is rigidly attached to a second identical force link and positioning assembly to the supporting frame. This arrangement allowed changing the initial inter-electrode gap without compromising the rigidity of the top assembly (electrode). The instantaneous displacement of the lower electrode is determined using an RDP (type GTX 2500) LVDT, the velocity using an RDP (Type 240A0500) self-induced velocity sensor and the acceleration using an Endevco (Type 7254-100) accelerometer, all three devices attached to the upper surface of the lower electrode. Electrical excitation of the ER fluid is achieved by means of a Trek (Model 664) high voltage amplifier, driven by a Thander (Model TG102) function generator. The Trek device allowed monitoring the applied voltage and the drawn current via 0-10V output monitoring facility. Data acquisition and processing are achieved using a Measurement Group (Type ESAM) analogue to digital converter that is controlled by a Pascal program running on an IBM compatible personal computer. Feedback control was not imposed in these tests but could be achieved, if required, using a Ling Dynamic Systems (Model DSC4) digital sine controller employing as input the signal from the accelerometer. In order that meaningful comparisons could

be made between the results of the various tests, the ER fluid temperature was controlled by re-circulating water through a second closed cavity in the lower electrode using a Grant Instruments (Model LTD6) temperature controller. Figure 1: Experimental Arrangement. The two force links were calibrated statically by sequential loading using small weights, while the LVDT was calibrated using a dial gauge. The accelerometer, pre-calibrated by the manufacturer, was found to function as specified to within ± 0.6% when its maximum transverse sensitivity was checked using the digital sine controller. As an additional check, the displacement signal from the LVDT was differentiated twice using central differences and the resulting signal was found to compare well with that from the accelerometer. Finally the data acquisition system was checked against a DC signal supplied by a millivolt calibration unit (Time Electronics Ltd, Model 404S) and was found to be accurate to within ± 0.5%. The ER fluid used in this investigation was supplied by Asahi Chemical Industry Co. and consisted of a liquid crystalline polysiloxanes diluted with polymethylsiloxane. 3. Results and Discussion An extensive testing programme has been conducted in order to assess the characteristics of a homogeneous ER fluid, employed in a squeeze cell that simulates a short stroke damper, under a range of electrical and mechanical input conditions. The tests carried out consisted of the simultaneous measurement of the input force delivered by the shaker, the transmitted force across the fluid, the displacement, velocity and acceleration of the lower electrode together with the applied voltage and the current through the fluid. These measurements were collected at a sampling frequency of 5 khz for a set of mechanical frequencies in the range 2 to 20 Hz. The input displacement amplitude of the lower electrode, for the electrically unstressed fluid, was chosen as 1.25 mm (peak to peak) at the resonant frequency of the system. The mean separation of the electrodes was chosen to be 2.0 mm. DC excitation of the ER fluid under test was in the range 0 to 2 kv. The temperature of the ER fluid was maintained at either 30 C or 50 C. The displacement (Peak to Peak) of the lower electrode and its dependence on the mechanical frequency is shown in Fig. 2 for three applied voltages between 0 and 1.0 kv and a fluid temperature of 30 C.

Figure 2: Input Displacement versus Frequency When the fluid is unstressed, there is a resonant peak at about 5 Hz and little damping of the lower electrode. It is evident that when a voltage of 1.0 kv was applied, the vibration is considerably reduced to small values for all frequencies within the range considered. However, at lower value of 0.5 kv, slightly higher displacement amplitudes were noticed particularly at frequencies lower than 6 Hz. A convenient representation of the performance of the ER cell is shown in Fig. 3 in which the force transmissibility, defined as the ratio of transmitted force to input force, is shown plotted against frequency for the same applied voltages. Figure 3: Force Transmissibility v Frequency For an applied voltage of 0.5 kv, it appears that the ER fluid exhibits solid body characteristics as the transmissibility remains close to unity. The performance of this fluid was then assessed under a temperature of 50 C and the results are summarised in Fig s. 4 and 5 in terms of input displacement and force transmissibility, respectively.

Figure 4: Input Displacement versus Frequency Figure 5: Force Transmissibility v Frequency It can be seen that this ER fluid showed weaker performance when the temperature increased from 30 C to 50 C, as 2.0 kv applied voltages could not reduce the input displacement to levels below 0.4 mm particularly for low frequencies. The increase in the level of the force transmitted by the fluid when subjected to high voltages could be ascribed to the stretching of the liquid crystalline polysiloxanes droplets, which coalesce to form bridges between the electrodes, increasing the apparent viscosity of the fluid. This may be similar to the formation of chains between the electrodes when a dispersed ER fluid is subjected to high electric fields. It is worth mentioning that although the input displacement of the lower electrode was considerably reduced, for the two fluid temperatures, when voltages of about 1.0 kv were applied, higher voltages could not suppress the vibration completely. This is contrary to the case of a dispersed ER fluid that was tested under similar conditions but was seen to be capable of completely arresting the shaker (El Wahed, 1998). In the second part of this investigation, the ER fluid was subjected to a step change in the applied voltage when the oscillation frequency was 5 Hz. Figure 6 shows the results of this test when the ER fluid temperature was maintained at 30 C. It can be seen that the input displacement undergoes an abrupt change on the application of 0.5 kv and this is accompanied by a rapid change in the level of the transmitted force. However, this ER fluid seems to require about 5 seconds to reduce the input displacement from 1.25 mm (peak to peak), measured just before the application of the step voltage, to 0.4 mm. Figure 6: Responses to Step Change in Voltage Figure 7 shows further decrease in the level of the input displacement and further increase in the level of the transmitted force. This growing strength of the fluid was seen to continue for about 40 seconds, which was the period that was allowed to elapse before the data presented in Figures 2 and 3 were collected. The first large decrease in the

level of the input displacement, shown in Fig. 6, may be ascribed to the elongation of the liquid crystalline polysiloxanes droplets whilst the further decrease, shown in Fig. 7, may be attributed to the formation of cylinders consisting of viscous polymer. Figure 7: Responses to Step Change in Voltage Figure 8: Responses to Step Change in Voltage Figure 8 shows the behaviour of this ER fluid when the fluid temperature was raised to 50 C and for a step change in the level of the applied voltage. The fluid, at this temperature, showed similar response although further reduction in the level of the input displacement was not noticed after the initial 5 seconds period, Fig. 9.

Figure 9: Responses to Step Change in Voltage The response of this fluid seems to be slow in comparison with that of the dispersed ER fluid that showed much faster response (El Wahed, 1996). The temperature dependence of the time response indicated the existence of a significant intermolecular interaction. 4. Conclusions In this paper, the characteristics of a homogeneous ER fluid, which consists of a liquid crystalline polysiloxanes diluted with polymethylsiloxane, was investigated under compressive and tensile stresses. This was necessary in order to explore ways by which the output of an ER cell, which is designed as a short stroke damper, may be maximised. The performance of this fluid was seen to be different in comparison with that of a dispersed ER fluid. This was evident in both the strength of the fluid represented by vibration amplitude suppression and force transmissibility, and the response time during which a strong ER effect was developed. 5. References Block, H., Kelly, J.P., Qin, A. and Watson, T., 1990, Langmuir, Vol. 6, pp. 6-14. El Wahed, A.K., Sproston, J.L., Stanway, R. and Williams, E.W., 2003, J. Sound & Vibration, Vol. 268, no. 3: 581-599. El Wahed, A.K., Sproston, J.L. and Stanway, R., 1998, J. Physics D: Applied Physics, Vol. 31: 2964-2974. El Wahed, A.K., Sproston, J.L. and Stanway, R., 1996, ASME, AMD Vol. 217, Atlanta, Georgia, November 1722, USA: 277-286, 1996. Inoue, A. and Maniwa, S., 1995, J. Applied Polymer Science, Vol. 55, no. 1: 113-118. Stanway, R., Sproston, J.L., Prendergast, M.J., Case, J.R. and Wilne, C.E., 1992, J. Electrostatics, Vol. 28: 89-94. Winslow, W.M., 1949, J. Applied Physics, Vol. 20: 1137-1140. 6. Responsibility notice The author is solely responsible for the printed material included in this paper.