Evaluation of kinetic-inductance nonlinearity in a singlecrystal NbTiN-based coplanar waveguide

Similar documents
Nonlinear kinetic inductance in TiN/NbTiN microresonators and Transmission lines. Peter Day Byeong-Ho Eom Rick Leduc Jonas Zmuidzinas

Ultrafast Optoelectronic Study of Superconducting Transmission Lines

arxiv: v1 [cond-mat.supr-con] 17 Jul 2015

Dynamical Casimir effect in superconducting circuits

arxiv: v1 [physics.ins-det] 13 Nov 2017

Superconducting Single-photon Detectors

Design and Characterisation of Titanium Nitride Subarrays of Kinetic Inductance Detectors for Passive Terahertz Imaging

Sensitivity of surface resistance measurement of HTS thin films by cavity resonator, dielectric resonator and microstrip line resonator

Zurich Open Repository and Archive. Current-Induced Critical State in NbN Thin-Film Structures

NONLINEAR TRAVELING-WAVE FIELD-EFFECT TRAN- SISTORS FOR MANAGING DISPERSION-FREE ENVE- LOPE PULSES

Low-loss superconducting resonant circuits using vacuum-gap-based microwave components

ECE 497 JS Lecture -07 Planar Transmission Lines

High-Temperature Superconducting Materials for High-Performance RF Filters

The Low Temperature Physics of Thin Films Superconducting Tin and Monolayer Graphene

QIC 890/891, Module 4: Microwave Parametric Amplification in Superconducting Qubit Readout experiments

GHZ ELECTRICAL PROPERTIES OF CARBON NANOTUBES ON SILICON DIOXIDE MICRO BRIDGES

TC 412 Microwave Communications. Lecture 6 Transmission lines problems and microstrip lines

Tunable Resonators for Quantum Circuits

Elastic Constants and Microstructure of Amorphous SiO 2 Thin Films Studied by Brillouin Oscillations

Microstrip Coupler with Complementary Split-Ring Resonator (CSRR)

Broadband ESR from 500 MHz to 40 GHz using superconducting coplanar waveguides

Superconducting Metamaterials

DEPOSITION OF THIN TiO 2 FILMS BY DC MAGNETRON SPUTTERING METHOD

Non-equilibrium superconductivity in microwave resonators

Retract. Press down D RG MG LG S. Recess. I-V Converter VNA. Gate ADC. DC Bias. 20 mk. Amplifier. Attenuators. 0.

A Radio For Hidden Photon Dark Matter

Magnetic Penetration Depth Measurements with the Microstrip Resonator Technique

MICROWAVE SURFACE IMPEDANCE OF A NEARLY FERROELECTRIC SUPERCONDUCTOR

Tuning of superconducting niobium nitride terahertz metamaterials

ECE 598 JS Lecture 06 Multiconductors

arxiv: v1 [cond-mat.supr-con] 8 Sep 2010

Analyzing of Coupling Region for CRLH/RH TL Coupler with Lumped-elements

Paper V. Acoustic Radiation Losses in Busbars. J. Meltaus, S. S. Hong, and V. P. Plessky J. Meltaus, S. S. Hong, V. P. Plessky.

On-Wafer Characterization of Electromagnetic Properties of Thin-Film RF Materials

Author(s) Tamayama, Y; Nakanishi, T; Sugiyama. Citation PHYSICAL REVIEW B (2006), 73(19)

Unidirectional spin-wave heat conveyer

Infrastructure of Thin Films Laboratory in Institute of Molecular Physics Polish Academy of Sciences

INTRODUCTION TO THE HYBRID PLASMA EQUIPMENT MODEL

Conventional Paper I (a) (i) What are ferroelectric materials? What advantages do they have over conventional dielectric materials?

Supercondcting Qubits

Analytical Solution for Capacitance and Characteristic Impedance of CPW with Defected Structures in Signal line

POTENTIAL OF Al 2 O 3 /GaN/SAPPHIRE LAYERED STRUCTURE FOR HIGH TEMPERATURE SAW SENSORS


Transmission-Reflection Method to Estimate Permittivity of Polymer

DIRECTIVITY AND SENSITIVITY OF HIGH FREQUENCY CARRIER TYPE THIN-FILM MAGNETIC FIELD SENSOR

Coplanar waveguide resonators for circuit quantum electrodynamics

Expressions for f r (T ) and Q i (T ) from Mattis-Bardeen theory

New Aspects of Old Equations: Metamaterials and Beyond (Part 2) 신종화 KAIST 물리학과

Physical Modeling and Simulation Rev. 2

Applications of Ferroelectrics for Communication Antennas

Impedance Matching and Tuning

Progress In Electromagnetics Research M, Vol. 20, 73 80, 2011

Progress In Electromagnetics Research B, Vol. 1, , 2008

HIGH-QUALITY-FACTOR superconducting resonators

Development of measurement technique to evaluate thermal conductivity of thermoelectric Bi 2 Te 3 submicron thin films by photothermal radiometry

NIOBIUM NITRIDE THIN FILMS AND MULTILAYERS FOR SRF APPLICATIONS

Josephson phase qubit circuit for the evaluation of advanced tunnel barrier materials *

EELE 3332 Electromagnetic II Chapter 11. Transmission Lines. Islamic University of Gaza Electrical Engineering Department Dr.

Nano and micro Hall-effect sensors for room-temperature scanning hall probe microscopy

M.C. Escher. Angels and devils (detail), 1941

Analytical Optimization of High Performance and High Quality Factor MEMS Spiral Inductor

MEASURE THE COMPLEX PERMEABILITY OF FER- ROMAGNETIC THIN FILMS: COMPARISON SHORTED MICROSTRIP METHOD WITH MICROSTRIP TRANS- MISSION METHOD

Zero-biased YBCO detectors for the real-time observation of coherent synchrotron radiation

Harmonic Balance Algorithms for the Nonlinear Simulation of HTS Devices

ECE 451 Transmission Lines & Packaging

Understanding EMC Basics

A TES Bolometer for THz FT-Spectroscopy

Electromagnetics in COMSOL Multiphysics is extended by add-on Modules

High Directivity Horn Antenna of Metamaterial in Terahertz Xiangjin Quan, Shiquan Zhang, Hui Li

Superconducting Flux Qubits: The state of the field

A Broadband Flexible Metamaterial Absorber Based on Double Resonance

Section 2 ADVANCED TECHNOLOGY DEVELOPMENTS

SIMULTANEOUS SWITCHING NOISE MITIGATION CAPABILITY WITH LOW PARASITIC EFFECT USING APERIODIC HIGH-IMPEDANCE SURFACE STRUCTURE

A New, Accurate Quasi-Static Model for Conductor Loss in Coplanar Waveguide

Large-scale Simulation for a Terahertz Resonance Superconductor Device

Nonlinear Metamaterial Composite Structure with Tunable Tunneling Frequency

Objective: Competitive Low-Cost Thin-Film Varactor Technology. Integrated Monolithic Capacitors using Sputtered/MOCVD material on low-cost substrates

Ferroelectrics. Spartak Gevorgian. Department of Microtechnology and Nanoscience Chalmers University of Technology Gothenburg, Sweden

ADMISSION TEST INDUSTRIAL AUTOMATION ENGINEERING

Paper Review. Special Topics in Optical Engineering II (15/1) Minkyu Kim. IEEE Journal of Quantum Electronics, Feb 1985

High-Resolution Gamma-Ray and Neutron Detectors For Nuclear Spectroscopy

MAGNETIC FIELDS & UNIFORM PLANE WAVES

Electron Spin Resonance Study Using Microwave Techniques

Probing Wigner Crystals in the 2DEG using Microwaves

A SYMMETRICAL DUAL-BAND TERAHERTZ META- MATERIAL WITH CRUCIFORM AND SQUARE LOOPS. Microsystem and Information Technology, Shanghai , China

Passive Coplanar Circulator with the Yig Thin Films

Nonlinear Effects in Optical Fiber. Dr. Mohammad Faisal Assistant Professor Dept. of EEE, BUET

UNIT I ELECTROSTATIC FIELDS

Prospective performance of graphene HEB for ultrasensitive detection of sub-mm radiation

Technique for the electric and magnetic parameter measurement of powdered materials

SUPPLEMENTARY MATERIAL

MICROWAVE AND MILLIMETERWAVE ELECTRICAL PERMITTIVITY OF GRAPHENE MONOLAYER. G. Konstantinidis 3

OPTI510R: Photonics. Khanh Kieu College of Optical Sciences, University of Arizona Meinel building R.626

A Robust Method of Calculating the Effective Length of a Conductive Strip on an Ungrounded Dielectric Substrate

A) n 1 > n 2 > n 3 B) n 1 > n 3 > n 2 C) n 2 > n 1 > n 3 D) n 2 > n 3 > n 1 E) n 3 > n 1 > n 2

Two-dimensional Cross Embedded Metamaterials

Simplified Measuring Method of kq Product for Wireless Power Transfer via Magnetic Resonance Coupling

Supporting Information

BiS 2 - based superconductivity in F-substituted NdOBiS 2

Combinatorial RF Magnetron Sputtering for Rapid Materials Discovery: Methodology and Applications

Transcription:

Proc. 14th Int. Conf. on Global Research and Education, Inter-Academia 2015 2016 The Japan Society of Applied Physics Evaluation of kinetic-inductance nonlinearity in a singlecrystal NbTiN-based coplanar waveguide Masanori Takeda 1 *, Takafumi Kojima 2, Atsushi Saito 3, Kazumasa Makise 4, and Hisashi Shimakage 5 1 Graduate School of Integrated Science and Technology, Shizuoka University, Hamamatsu, Shizuoka 432-8011, Japan 2 Advanced Technology Center, National Astronomical Observatory of Japan, Mitaka, Tokyo 181-8588, Japan 3 Graduate School of Science and Engineering, Yamagata University, Yonezawa, Yamagata 992-8510, Japan 4 Advanced ICT Research Center, NICT, Kobe, Hyogo 651-2492, Japan 5 College of Engineering, Ibaraki University, Hitachi, Ibaraki 316-8511, Japan E-mail: takeda.masanori@shizuoka.ac.jp (Received September 25, 2015) We have developed a kinetic inductance travelling-wave amplifier toward the THz-band operation. In this paper, we discuss the nonlinear kinetic inductance of single-crystal niobium titanium nitride (NbTiN) thin film in response to the application of current to the film. In our calculation, it is found that single-crystal NbTiN films have a large current variation in the kinetic inductance compared with that of polycrystalline NbTiN films. To evaluate the nonlinearity, we fabricated a superconducting coplanar waveguide with a 0.2-m line length and measured the transmittance. We observed a variation of the electrical length of the line caused by the modulation of the kinetic inductance as a function of the value of the current applied to the strip. 1. Introduction Microwave amplifiers with extremely low-noise performance that approach quantum-limited noise have been desired as read-out circuits in microwave kinetic inductance detectors (MKIDs) for radio astronomical observations [1, 2] and for superconducting quantum-bit experiments toward the realization of quantum computation [3, 4]. In addition to low-noise performance, microwave amplifiers that can operate over broadband and with low-power consumption are preferable in the above applications. However, it is difficult to achieve all of these attributes simultaneously. Recently, a new type of amplifier has been proposed, known as the kinetic inductance travelling-wave (KIT) amplifier [1]. This amplifier has the promise to achieve quantum limited noise, broad bandwidth, and high dynamic range. Superconducting thin films have a kinetic inductance in addition to a magnetic inductance. The current variation of the kinetic inductance of a superconducting wire is expected to be quadratic to lowest order, that is L k (I) L k (0) [1 + ( I I ) 2 ], (1) where I * is on the order of the critical current. The KIT amplifier consists of a superconducting transmission line and utilizes the intrinsic nonlinearity of the superconducting kinetic inductance for parametric amplification. Since the nonlinearity of the kinetic inductance per unit wavelength is typically small, a longdistance interaction between the pump and the signal tones is required to achieve a high parametric 011502-1

011502-2 gain in the KIT amplifier. In Ref. [5], a 2.2-m-long NbTiN coplanar waveguide (CPW) was used to obtain a gain of 15 db at 7 GHz. In such a long transmission line, an important consideration is the transmission loss. Transmission loss results in a reduction of the effective line length for the parametric interaction and degrades the gain and noise performance. In principle, the KIT amplifier is possible to scale up to the superconducting gap frequency based on the effective wavelength. With a high-frequency operation, the selection of a superconducting material with smaller surface resistance becomes more important. And, from Eq. (1), the variation in the kinetic inductance relates closely to a critical current density of the film. With a same applied current, the larger variation can be expected in the film with a lower current density. In other words, it is possible to reduce the pump power necessary to achieve a moderate parametric gain in the KIT amplifier consisted of a film with a low critical current density. The reduction of the pump power is very useful as the operation frequency becomes high, especially in the THz band, because the available power is limited. We have developed the KIT amplifier toward the THz-band operation. The single-crystal NbTiN films have lower values in both of the surface resistance and the critical current density compared with those of polycrystalline NbTiN films. Therefore, we consider that the single-crystal NbTiN film becomes a good candidate for the material of the KIT-amplifier as the operation frequency becomes high. In the present paper, we report on the evaluation of kinetic-inductance nonlinearity in singlecrystal NbTiN-based CPW. The measurements were performed in the microwave band as the scalemodel experiments. 2. Superconducting properties of NbTiN thin films 2.1 Fabrication NbTiN thin films were prepared by reactive DC magnetron sputtering in a load-lock sputtering system at ambient temperature. The compounding ratio of the 8-inch NbTi target was 100:20 (Nb:Ti) by weight. The NbTiN films were deposited on (100) MgO and fused quartz substrates in a gaseous mixture of Ar and N 2 with a total pressure of 2 mtorr. The gas flow rate of Ar and N 2 was set at 100 and 36 sccm, respectively. The crystalline structures of NbTiN films depend strongly on substrates [6]. By X-ray diffraction (XRD) measurement, we confirmed strong (200) XRD peaks for the NbTiN film and MgO substrate, as shown in Fig. 1(a), indicating that NbTiN films could be epitaxially grown on MgO substrates. On the other hand, some quite weak XRD peaks were observed in the NbTiN film on fused quartz substrate, as shown in Fig. 1(b). The single-crystal NbTiN film on MgO substrate and polycrystalline NbTiN on fused quartz substrate showed critical temperature, T C, of 14.4 K and 12.7 K, and 20-K resistivity, 20K of 51.2 cm and 84.2 cm, respectively. Fig. 1. X-ray diffraction patterns of 40-nm-thick NbTiN thin films fabricated on (a) MgO and (b) fused quartz substrates.

011502-3 Fig. 2. (a) Surface resistance of single-crystal and polycrystalline NbTiN thin films at 21.8 GHz as a function of temperature. The temperature is normalized to each superconducting transition temperature. (b) The calculated and measured surface resistances at 5 K as a function of frequency. 2.2 Surface resistances The surface resistance of the NbTiN thin films was measured using the dielectric resonator method at 21.8 GHz. A dielectric resonator is composed of a sapphire rod sandwiched between two identical NbTiN thin films as upper and bottom electrodes. The microwave signal enters the resonator through a loop antenna and is detected by another loop antenna. The frequency characteristics of the transmission attenuation can be measured using a vector network analyzer. From an unloaded quality factor in the resonator, we can estimate the surface resistance of the film. Figure 2(a) shows the surface resistance of the single-crystal NbTiN thin film on an MgO substrate and the polycrystalline NbTiN thin film on a fused quartz substrate at 21.8 GHz, as a function of temperature normalized to the superconducting transition temperature. Figure 2(b) shows the surface resistance of those films at 5 K, as calculated by applying the Mattis-Bardeen theory as a function of frequency [7]. The measurement results of those films at 21.8 GHz were consistent with the calculation results. Because the surface resistance of superconductors increases proportional to the square of frequency as shown in Fig. 2(b), the use of the single-crystal NbTiN film is advantageous for the reduction of a transmission loss as the operation frequency of the KIT amplifier becomes high. 2.3 Kinetic-inductance nonlinearity We calculated the nonlinearity of the kinetic inductance in a superconducting CPW using the measured superconducting properties. The total inductance per unit length in a superconducting CPW, L T, is expressed by L T = L m + L k, (2) where L m and L k are the magnetic inductance and kinetic inductance, respectively. When the film thickness is thinner than the penetration depth, NbTiN, those inductances can be calculate by the conformal mapping technique [8], L m = μ 0 K(k ) (3) 4 K(k) λ L k = μ NbTiN 0 g(s, w, d) (4) dw where 0 is the vacuum permeability, K(k) is the complete elliptic integral of the first kind with a modulus k = w (w + 2s), k = 1 k 2, d is the film thickness, w is the width of the centre electrode and s is the spacing between the grounded electrode and the centre electrode. In addition,

011502-4 Fig. 3. Kinetic inductance in superconducting single-crystal-nbtin CPW. (a) Film-thickness dependence, (b) CPW-dimension dependence. Fig. 4. Variations in kinetic inductance of a NbTiN CPW with a spacing between the grounded and centre electrodes of 2 m and a thickness of 45 nm as a function of applied current. From magnetization measurements, the critical current densities were set to be 1.3 MA/cm 2 and 2.8 MA/cm 2 in the singlecrystal and polycrystalline films, respectively, and the measured values are used in the calculations. (a) Comparison between single-crystal (solid line) and polycrystalline (dashed line) NbTiN films. (b) Centreelectrode-width dependence in a single-crystal NbTiN CPW. g(s,w,d) is a geometrical factor given as: 1 d g(s, w, d) = 2k 2 K(k) 2 { ln w ln d + 2(w+s) ln s }. (5) 4w w+2s 4(w+2s) w+2s w+s Figure 3(a) shows the film-thickness dependence, and 3(b) shows the line-dimension dependence of the kinetic inductance in a single-crystal-nbtin CPW. The kinetic inductance is normalized to the total inductance. From Figs. 3(a) and 3(b), the kinetic inductance is dominant when the thickness of the electrode and the width of the centre electrode is reduced. By applying a current to a superconducting transmission line, the kinetic inductance is modulated according to Eq. (1). Figure 4 shows variations in the kinetic inductance as a function of the applied current. The spacing, s, and the film thickness, d, were set to be 2 m and 45 nm, respectively. In the calculations, the measured superconducting properties were used. Figure 4(a) shows a comparison of the variation between single-crystal and polycrystalline NbTiN films. In the single-crystal NbTiN film, it is found that a large variation in the kinetic inductance can be expected or the required current can be reduced to achieve the same variation in the single-crystal NbTiN film, if the same CPW structure is assumed. In addition, the centre-electrode-width dependence of variations in the kinetic inductance is shown in Fig. 4(b). A large variation in the kinetic inductance to the applied current can be obtained by reducing the width of the centre electrode.

011502-5 3. Experimental results We fabricated a 0.2-m single-crystal-nbtin CPW on a 10-mm square MgO substrate. The width of the centre electrode and the spacing between the grounded electrode and the centre electrode were 4 m and 2 m, respectively. The film thickness was 45 nm. When a current I is applied to the strip and the kinetic inductance is modulated by the current, the electrical length of the CPW changes by, according to the following equation: Δθ = {β(i) β(0)}l = ω{ L T (I)C L T (0)C}l δl k (6) where and l are the propagation constant and the length of the CPW, respectively. Because the variation of the electrical length is proportional to that of the kinetic inductance, L k, we measured the amplitude and phase of the transmission coefficient S 21 in the fabricated CPW using a vector network analyzer at 5 GHz at 4 K. The measurement setup is shown in Fig. 5. DC current was applied to the strip conductor of the CPW through a bias tee. The vector network analyzer was calibrated so that S 21 became the reference when the DC current was not applied. Figure 6(a) shows the variation of the electrical length and the amplitude of S 21 at 5 GHz as a function of the applied DC current. The variation,, is normalized to the electrical length ( = 91 rad) when the current is not applied. Each measuring point represents the mean value for five measurements. In Fig. 6(a), we find that the electrical length changes nonlinearly with respect to the applied current without a degradation of the transmission characteristic. However, the observed variation of the electrical length was small. To clarify the cause we performed a comparison between the measurement and calculation results. For the comparison, the measured variation of the electrical length was transformed to the total inductance based on Eq. (6), where the capacitance used the calculated value (C = 93 pf). The ratio of total inductance when the DC current is not applied to it when the DC current is applied is shown in Fig. 6(b). The theoretical calculations of designed width (w = 4 m) and reduced width (w = 2 m) of the centre electrode are also shown in Fig. 6(b). The calculation was performed based on the method described in Sec. 2.3. A critical current density of 1.7 MA/cm 2 was used in the calculation, because the fabricated CPW was able to conduct the current up to 3 ma without a voltage drop. Assuming that the variation of the total inductance is caused by that of the kinetic inductance, the kinetic inductance varies about 5% by increasing the current up to the critical current. In addition, the calculation result approximately matches the measurement result. Therefore, it is considered that the cause of the small kinetic-inductance variation in the measurement result is due to the wider width of the center electrode. Strong nonlinearity is expected by reducing the width of the centre electrode and increasing the intrinsic kinetic inductance, as shown in Fig. 6(b). Fig. 5. Measurement setup for the evaluation of nonlinear kinetic inductance.

011502-6 Fig. 6. (a) Measured phase shift (circles) and transmission loss (squares) of the fabricated CPW as a function of applied current. (b) Total-inductance variation of the fabricated CPW evaluated from the measured phase shift and from the theoretical calculation (solid line). The total inductance significantly changes by reducing the width of the centre electrode (dashed line). 4. Conclusion We have developed a KIT amplifier composed of a single-crystal NbTiN-based CPW. In our calculation, it is found that single-crystal NbTiN films have a large current variation in the kinetic inductance compared with that of polycrystalline NbTiN films. The fabricated single-crystal-nbtin CPW has a length of 0.2 m, a centre electrode width of 4 m, a CPW gap of 2 m and a film thickness of 45 nm, and the transmission characteristic is measured at 4 K in the microwave band. By applying a current to the centre electrode, we observed a nonlinear change in the electrical length without a degradation of the transmission characteristic. This indicates that the kinetic inductance changes nonlinearly with the applied current. However, the observed variation of the electrical length was small. It is found that the cause is due to the wider width of the centre electrode by comparison with the theoretical calculation. In the future, as we continue to develop the KIT amplifier, we will fabricate a CPW with a very narrow strip in order to enhance the kinetic-inductance nonlinearity. Acknowledgment This work was supported by JSPS KAKENHI Grant Number 26420305. References [1] B. H. Eom, P. K. Day, H. G. LeDuc, and J. Zmuidzinas: Nature Phys. 8 (2012) 623. [2] C. Bockstiegel, J. Gao, M. R. Vissers, M. Sandberg, S. Chaudhuri, A. Sanders, L. R. Vale, K. D. Irwin, and D. P. Pappas: J. Low. Temp. Phys. 176 (2014) 476. [3] J. Hansryd, P. A. Andrekson, M. Westlund, J. Li, and P. O. Hedekvist: IEEE J. Selected Topics in Quantum Electron. 8 (2002) 506. [4] A. Lupascu, S. Saito, T. Picot, P. C. de Groot, C. J. P. M. Harmans, and E. Mooij: Nature Phys. 3 (2007) 119. [5] C. Bockstiegel, J. Gao, M. R. Vissers, M. Sandberg, S. Chaudhuri, A. Sanders, L. R. Vale, K. D. Irwin, D. P. Pappas: J. Low. Temp. Phys. 176 (2014) 476. [6] K. Makise, H. Terai, M. Takeda, Y. Uzawa, and Z. Wang: IEEE Trans. Appl. Supercond. 21 (2011) 139. [7] D. C. Mattis and J. Bardeen: Phys. Rev. 111 (1958) 412. [8] K. Watanabe, K. Yoshida, T. Aoki, and S. Kohjiro: Jpn. J. Appl. Phys. 33 (1994) 5708.