Method Development with ZirChrom's Ion Exchange Phases

Similar documents
Zirconia: the Ideal Substrate for Ion-Exchange LC and LC-MS

Fast Analysis of Small MW Analytes in a Beverage and Serum Samples on a Zirconiabased Strong Anion-Exchanger

Oligonucleotide Separation on ZirChrom -SAX

Multi-mode Separations Using Zirconiabased Stationary Phases

Liquid Chromatography

New Applications of Zirconia Based Stationary Phases

1. Ion exchange chromatography

Cation Exchange HPLC Columns

Novel LC/MS-Compatible Stationary Phase with Polar Selectivity

ProPac WCX-10 Columns

Sepax SRT -C, Zenix -C SEC Phases

Ion Chromatography. Anion Exchange. Chromatography Ion Exchange Theory. Dr. Shulamit Levin

No.106. Aqueous SEC Columns for Analysis of Cationic Polymers: TSKgel PWXL-CP Series. Contents. Page

Cation Exchange HPLC Columns

Acclaim Mixed-Mode WAX-1 Columns

Zirconia-Based Phases as a Powerful Complement to Silica-Based Phases for LC and LC-MS under Non-extreme Mobile Phase Conditions

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SeQuant ZIC-HILIC. Catalogue 9. Hichrom Limited

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SIELC Primesep. Catalogue 9. Hichrom Limited

Analysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography

LC and LC/MS Column Selection Flow Chart

SRT -10/10C (10 µm ) Fast Protein Purification For FPLC, HPLC and Prep LC. Sepax Technologies, Inc. Preparative Size Exclusion Chromatography

The Secrets of Rapid HPLC Method Development. Choosing Columns for Rapid Method Development and Short Analysis Times

Thermo Scientific. Acclaim Trinity P2. Column Product Manual. P/N: October Part of Thermo Fisher Scientific

Sunniest C18 Sunniest RP-AQUA Sunniest C8 Patent pending

Fast Separation of Vastly Different Compounds by Isocratic HPLC

Basic Chemistry. Chemistry Review. Bio 250: Anatomy & Physiology

Harris: Quantitative Chemical Analysis, Eight Edition CHAPTER 25: CHROMATOGRAPHIC METHODS AND CAPILLARY ELECTROPHORESIS

Packings for HPLC. Packings for HPLC

Analysis - HPLC A.136. Primesep 5 µm columns B.136

Reversed-Phase Method Development Guide

Basic Chemistry. Chapter 2 BIOL1000 Dr. Mohamad H. Termos

Anion Exchange HPLC Columns

Hints for Strong Ion Exchange Resins

4. Ion chromatography (IC) 4.1. Educational aims and objectives

Hole s Human Anatomy and Physiology Tenth Edition. Chapter 2

Hole s Human Anatomy and Physiology Eleventh Edition. Chapter 2

Chromatographic Methods of Analysis Section - 4 : Ion Exchange Chrom. Prof. Tarek A. Fayed

Applications and Properties of New Polymeric Mixed Mode Cation Exchange Chromatography Media

Comparison of different aqueous mobile phase HPLC techniques

columns Acclaim Mixed-Mode WCX-1 for Separating Basic Molecules

Where does Physical Chemistry fit into your course in Dentistry?

penta-hilic UHPLC COLUMNS

Chapter 2 The Chemistry of Life

Chapter Two Test Chemistry. 1. If an atom contains 11 protons and 12 neutrons, its atomic number is A. 1 C. 12 B. 11 D. 23

Polymer Coated Titania for Analytical and Preparative Reversed-Phase Chromatography

Biology 30 The Chemistry of Living Things

Teacher Instructions

Too Polar for Reversed Phase What Do You Do?

Dionex IonPac AS28-Fast-4µm column

1/23/2012. Atoms. Atoms Atoms - Electron Shells. Chapter 2 Outline. Planetary Models of Elements Chemical Bonds

NORTH CENTRAL HIGH SCHOOL NOTE & STUDY GUIDE. Honors Biology I

8. Methods in Developing Mobile Phase Condition for C18 Column

Biochemistry. Basic Chemistry Review, ph, Water, Organic Molecules

Shodex TM ODP2 HP series columns

Chapter 2 The Chemistry of Biology. Dr. Ramos BIO 370

Advantages of polymerbased. an alternative for ODS

Polymer Coated Titania for Analytical and Preparative Reversed-Phase Chromatography

PTYS 214 Spring Announcements. Midterm #1 on Tuesday! Be on time! No one enters after the first person leaves! Do your homework!

HPLC Columns and Accessories. Solutions for liquid chromatography

Chemical Basis of Life

(HILIC) Bill Champion Agilent Technologies, Inc opt 3/opt3/opt 2 HILIC - Agilent Restricted

TSKgel Size Exclusion Chromatography Columns

GFC Analysis of Water-Soluble Polymers with TSKgel PW-type Columns. Contents

A Platform Method for Pharmaceutical Counterion Analysis by HPLC

An atom is the smallest unit of an element. It has: A general understanding of chemistry is necessary for understanding human physiology.

Acclaim Mixed-Mode WCX-1

penta-hilic UHPLC COLUMNS

Cellufine Butyl Cellufine Phenyl

SHORT ANSWER. Write the word or phrase that best completes each statement or answers the question.

groups I and II cations, amines, divalent transition metals

Utilizing ELSD and MS as Secondary Detectors for Prep HPLC and Flash Chromatography. Tips and Techniques to Optimize ELSD and MS based Purification

HPLC Columns and Accessories. Solutions for liquid chromatography

Cellufine Butyl Cellufine Phenyl

2/25/2013. Electronic Configurations

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

Simultaneous Determination of Paraquat and Diquat in Environmental Water Samples by HPLC-MS/MS

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Zorbax. Catalogue 9. Hichrom Limited

Rapid Screening and Analysis of Components in Nonalcoholic Drinks Application

INSTALLATION INSTRUCTIONS and TROUBLESHOOTING GUIDE. for the OnGuard- CARTRIDGE

Impact of Pore Exclusion on Reversed-Phase HPLC Column Performance

Full file at

Chapter 2: Chemistry. What does chemistry have to do with biology? Vocabulary BIO 105

The Chemistry of Microbiology

LC Columns with Liquid Separation Cell Technology

Improve HPLC Separations by Carefully Matching Column Pore-Size to Solute-Size

Introduction to Life Science. BSC 1005 Fall 2011 Homework 1! Connect Due Date: 9/18/ :59PM. Multiple Choice Portion

SEPARATIONS ESSENTIALS IN MODERN HPLC. 2University of Bucharest, Bucharest, Romania

Chapter 02 Chemical Composition of the Body

Properties of Compounds

Chapter 2 Chemical Aspects of Life

How proteins separate on reverse-phase HPLC

Chemical Principles. PowerPoint Lecture Presentations prepared by Bradley W. Christian, McLennan Community College C H A P T E R

Microbiology with Diseases by Taxonomy, 5e (Bauman) Chapter 2 The Chemistry of Microbiology. 2.1 Multiple Choice Questions

Lab 2 Atomic Level of Organization

2017 Ebneshahidi. Dr. Ali Ebneshahidi

Reversed Phase Solvents

Optimisil HPLC & UPLC Column catalogue

chapter A solution is a mixture composed of two or more substances that are physically blended but not chemically combined.

columns IonPac AS17-C Anion Exchange Column

for Acclaim Trinity TM P1

Transcription:

For Peak Performance ZIRCHROM ION EXCHANGERS Phases for Sugars and Proteins Wide Range of Ion Exchange Selectivity No Shrinking or Swelling Use Any Organic Solvent Significantly Higher Efficiency than Polymeric Phases Method Development with ZirChrom's Ion Exchange Phases Each ZirChrom ion exchange phase is produced by coating ultra-stable zirconia particles with an extremely thin layer of an ionic polymer. This method creates phases with much higher efficiency and, oftentimes, higher capacity than pure polymeric phases. Also, ZirChrom's ion exchangers do not shrink or swell as a function of ionic strength or organic modifier content of the mobile phase. ZirChrom's SAX and SHAX phases are thermally stable up to 80 C, which causes different selectivity, allowing high speed separations with lower ionic strength mobile phases. This is very important in the preparation of RNA and DNA samples. If desired, mixed-mode separation modes may be exploited to optimize separations, including Lewis acidbase interactions, hydrophobic interactions and ionexchange interactions. These modes may be attenuated by adjusting the strong Lewis base content, organic content and ionic strength of the mobile phase, respectively. For more detailed guidelines, consult our Technical Bulletins for examples of the use of these phases. Or, contact our technical support group at -866-STABLE-. ZirChrom -SHAX Sugars on ZirChrom -WAX - Human insulin - Xylose - Glucose - Sucrose - Lactose 5 - Maltose 5 0 5 6 min Mobile phase: 5/85 0.5 mm Ammonium hydroxide, ph.6/ 0 mm Ammonium acetate, ph0.0 Flow rate:.0 ml/min Temperature: 0 C Injection volume: 5 µl Detection: 5 nm Column: ZirChrom -SHAX, 50 x.6 mm i.d. (part# ZR07-56) 0 6 8 0 Time (min) Mobile phase: 85/5 85// 0.5 ACN/Water/Methanol (part# ZR05-56) Flow rate:.0 ml/min Temperature: Ambient Detection: ELSD Column: ZirChrom -WAX, 50 x.6 mm i.d. ZirChrom Separations, Inc., 67 Pierce Street, Anoka, MN 550

HPLC COLUMN PRODUCT GUIDE 0-0 ION EXCHANGE CHROMATOGRAPHY "Green" Analysis of Diet Soft Drinks on ZirChrom -SAX - Caffeine - Aspartame - Benzoate Diet Sprite Diet Dr. Pepper Diet Mountain Dew Diet Coke Diet Pepsi 0 5 6 min Mobile phase: 0mM Ammonium phosphate, 5mM Ammonium carbonate, ph 6.6 Flow rate:.0 ml/min Temperature: 50 C Injection volume: 5 µl Detection: 0 nm Column: ZirChrom -SAX, 00 x.0 mm i.d. (part# ZR06-00) Organic Acids ZirChrom -SAX - Acetic acid - Propionic acid - Formic acid - Butyric acid 0 0.5.5.5.5.5 min Mobile phase: 5 mm Ammonium phosphate, ph 6.0 Flow rate:.5 ml/min Temperature: 50 C Injection volume: 5 µl Detection: 0 nm Oligonucleotides ZirChrom -SAX Pressure drop: 0 bar Column: ZirChrom -SAX, 50 x.6 mm i.d. (part# ZR06-56) Partial Poly (G) hydrolysate Water Soluble Vitamins on ZirChrom -SAX - Thiamine (Vitamin B ) - Pyridoxine (Vitamin B 6) - Nicotinamide (form of Vitamin B ) - Riboflavin (Vitamin B ) 5 - Nicotinic acid (form of Vitamin B ) 6 - Ascorbic acid (Vitamin C) 0 5 6 min Mobile phase: 50 mm Ammonium dihydrogenphosphate, ph.5 Flow rate:.0 ml/min Temperature: 0 C Injection volume: 5 µl Detection: 5 nm Column: ZirChrom -SAX, 50 x.6 mm i.d. (part# ZR06-56) 5 6 0 0 0 60 80 000 0 Mobile phase: (A) 0 mm Potassium phosphate dibasic at ph 7.0, 00 mm Sodium chloride (B) 00 mm Potassium phosphate dibasic at ph 7.0,.0 M Sodium chloride; Gradient: 0 to 90% B over 80 min. Flow rate:.0 ml/min Injection volume: 5 µl Protein Separations ZirChrom -PEZ Temperature: 00 C Detection: 60 nm - Water - Myoglobin - Lysozyme - Oxidized and reduced forms of Cytochrom C 0 5 6 7 8 9 min Mobile phase: Gradient elution with 5 to 00% B over 0 min. where A is mm EDTPA, 50 mm NaCI, 0 mm MES, ph 5.5, and B is mm EDTPA,.0 M NaCI, 0 mm MES, ph 5.5 Flow rate:.0 ml/min Injection volume: Volume: 50 µl µl Temperature: 0 C Detection: 5 80 nm Column: ZirChrom -PEZ, 50 x.6 mm i.d. (part# ZR08-56) Column: ZirChrom -SAX, 50 x.6 mm i.d. (part# ZR06-56) *NOTE: The high temperature specification for ZirChrom -SAX is 80 C. Routine column use above the high temperature specification will significantly shorten column lifetime. tel -866-STABLE- / fax -76--9 / www.zirchrom.com 5

For Peak Performance ION EXCHANGE CHROMATOGRAPHY Legend for Surface Chemistry Diagrams ZirChrom -WAX (Stable from ph -9, and to 50 C) ZirChrom -SAX (Stable from ph -, and to 80 C) Cross-linked polyethyleneimine-coated zirconia for weak anion-exchange Efficient weak anion-exchanger useful for inorganic and organic anions Useful for the separation of bio-molecules such as nucleotides, nucleosides, oligonucleotides, oligodeoxynucleotides, amino acids, peptides, and proteins Extremely stable amino phase for normal phase separation of carbohydrates ZirChrom -WCX (Stable from ph -0, and to 50 C) Cross-linked polyethyleneimine-coated zirconia for strong anion-exchange Useful for inorganic and organic anions Ideal for the separation of water-soluble vitamins Useful for the separation of bio-molecules such as nucleotides, nucleosides, oligonucleotides, oligodeoxynucleotides, amino acids, and peptides ZirChrom -SHAX (Stable from ph -, and to 80 C) Phosphate-coated zirconia for weak cation-exchange Useful for protein chromatography in the cationexchange mode ZirChrom -PEZ (Stable from ph -0, and to 50 C with mobile phase additive) Quaternized polyethyleneimine-coated zirconia for strong hydrophilic anion-exchange. EDTPA-coated zirconia for cation-exchange Useful for protein chromatography in the cationexchange mode ZirChrom-SHAX has all the advantages of ZirChrom- Excellent phase for monoclonal antibody separations SAX except that the surface is much more hydrophilic making it useful for anion-exchange of proteins PACKING MODE PART ZirChrom -WCX Weak Cation-Exchange ZR0 ZirChrom -WAX Weak Anion-Exchange ZR05 ZirChrom -SAX Strong Anion-Exchange ZR06 ZirChrom -SHAX Strong Hydrophilic Anion-Exchange ZR07 ZirChrom -PEZ Cation-Exchange for Proteins ZR08 Microbore, Semi-Prep and Prep Formats Available see Page 6 ZirChrom Separations, Inc., 67 Pierce Street, Anoka, MN 550

Technical Bulletin #6 Ion Exchange Phase Column Selection Guide CURRENT PROBLEM/CONCERN COLUMN SUGGESTED CONDITIONS Improve Selectivity Need improved selectivity for proteins. ZirChrom -PEZ Use at ph below protein pi with EDTPA, MES, ZirChrom -WCX ZirChrom -WAX and NaCl. Use at neutral ph with up to 500mM phosphate. Employ ph and ionic strength (salt) elution gradients. Need improved selectivity for organic anions including ZirChrom -SAX Use at neutral ph with phosphate and NaCl. nucleic acids. Need improved selectivity for organic cations. ZirChrom -WCX Use at low to neutral ph with phosphate. ZirChrom -PEZ Use at low to neutral ph with TFA and EDTPA. Need improved selectivity for sugars. ZirChrom -WAX Acetonitrile / buffer (00mM NH HCO ph 9). Change Retention Need more retention for proteins or organic cations. ZirChrom -WCX Adjust ph, lower ionic strength. Need less retention for proteins or organic cations. ZirChrom -PEZ Adjust ph, increase ionic strength. Need more retention for organic anions, nucleic acids, & ZirChrom -SAX Lower phosphate and ionic strength. oligonucleotides. Need less retention for organic anions including nucleic ZirChrom -WAX Increase phosphate and ionic strength. acids. Improve Dynamic ph Range Stability Need more ph range stability for proteins or organic ZirChrom -WCX Stable from ph to ph 0. cations. ZirChrom -PEZ Need more ph range stability for organic anions including ZirChrom -SAX Stable from ph to ph. nucleic acids. Change Selectivity from Current Phase If analytes do not separate on silica based anion phase. ZirChrom -SAX For different selectivity. If analytes do not separate on polymer based anion phase. ZirChrom -SHAX For different selectivity. ZirChrom -WAX If analytes do not separate on polymer based cation phase. ZirChrom -WCX For different selectivity. ZirChrom -PEZ Improve Efficiency / Productivity If separations are taking too long. All Columns Employ maximum operating temperature, increase flow. If resolution is not adequate. All Columns Employ and optimize ph and ionic strength gradients.

Technical Bulletin #5 Characteristics of ZirChrom Ion Exchange Phases Type Characteristic WCX SHAX SAX WAX PEZ High ph Stability Fair Excellent Excellent Fair Fair Physical Low ph Stability Excellent Excellent Excellent Fair Excellent High Temp Stability Very Good Very Good Very Good Fair Very Good Charge Density / Retentivity Highest High Highest Moderate Moderate Silica Based Anion NA Close Different Close NA Similarity to Polymer Based Anion NA Different Close Different NA Other Polymer Based Sulfonic Acid Different NA NA NA Different Ion Cation Exchangers Polymer Based Carboxylic Different NA NA NA Different Acid Cation For Protein Purification Good Fair Poor Fair Excellent Nucleic Acid NA Good Best Good NA Selectivity Organic Anion NA Good Good Good NA Organic Cation Good NA NA NA Good Inorganic Anion NA Good Good Good NA