Leninsky prosp., 59, Moscow, , Russian Federation, Leninsky prosp., 31, Moscow, , Russian Federation

Similar documents
Swift heavy ion irradiation effect on the surface of sapphire single crystals

Nanopores with controlled profiles in track-etched membranes

, MgAl 2. and MgO irradiated with high energy heavy ions O 3

Swift heavy ion irradiation effects. in condensed matter. K. Havancsák

Low-adsorbing track-etched membrane

Single-sheet identification method of heavy charged particles using solid state nuclear track detectors

Etching Properties of Polyethyleneterephthalate (PET) Melinex-E Nuclear Track Detectors (NTDs)

Nanofluidics and 2D Materials Based Nanosensors. Ivan Vlassiouk Oak Ridge National Laboratory, TN, USA

Computer simulation and study of the IR spectra of irradiated polymer materials

Chapter 2 Chemistry of High-Energy Charged Particles: Radiations and Polymers

Controlled change of transport properties of poly(ethylene terephthalate) track membranes by plasma method

I. 16. Coloration of Polyethylene Terephthalate (PET) Film by 3MeV Proton Beams

Keywords: experimental verification; LiF:Mg,Cu,P; lithium fluoride; radial dose distribution

WIDE-POROSITY SILICAS FOR HIGH- PERFORMANCE LIQUID CHROMATOGRAPHY

Initiation of nuclear reactions under laser irradiation of Au nanoparticles in the aqueous solution of Uranium salt. A.V. Simakin and G.A.

Gamma Irradiation Effects on Track Properties of PADC-American Acrylics Track Detector

ELEMENTARY RADIATION CHEMISTRY

ABSTRACT. Keywords: CR-39 Detector, chemical etching techniques, new etchant, Methanol. INTRODUCTION

STRUCTURE AND DIELECTRIC PROPERTIES OF NANOCOMPOSITES ON THE BASIS OF HIGH-DENSITY POLYETHYLENE AND LEAD SULFIDE

The electron diffusion into the channel of stationary plasma thruster

Neutron dosimetry and microdosimetry with track etch based LET spectrometer

Kobe University Repository : Kernel

Study of Radiation Effect on Petroleum Oils

INFLUENCE OF EXPOSURE GEOMETRY ON THE RESPONSE OF CR39 SSNT RADON DETECTORS *

Nuclear Instruments and Methods in Physics Research B

Chemical etching characteristics for cellulose nitrate

Variation of Bulk Etch Rate and some other Etching Parameters with Etching Temperature for Cellulose Nitrate LR-115 Detector

NUCLEAR EMISSIONS FROM TITANIUM HYDRIDE/DEUTERIDE INDUCED BY POWERFUL PICOSECOND LASER BEAM

New Calibrations and Time Stability. of the Response of the INTERCAST CR-39

Peculiarity of polymeric materials destruction on the low Earth orbits

APPLICATION OF THE NUCLEAR REACTION ANALYSIS FOR AGING INVESTIGATIONS

Available online at ScienceDirect. Physics Procedia 90 (2017 )

Ion Implanter Cyclotron Apparatus System

The possibility to use energy plus transmutation set-up for neutron production and transport benchmark studies

INTRODUCTION TO IONIZING RADIATION (Attix Chapter 1 p. 1-5)

Applications of Micro-Area Analysis Used by JPS-9200 X-ray Photoelectron Spectrometer

Method of active correlations in the experiment 249 Cf+ 48 Ca n

E. V. Samsonov, B. N. Gikal, O. N. Borisov, I. A. Ivanenko NUMERICAL SIMULATION OF ION ACCELERATION AND EXTRACTION IN CYCLOTRON DC-110

APPLIED RADIATION PHYSICS

Polymer analysis by GPC-SEC. Technical Note. Introduction

Applications of ion beams in materials science

Experimental data analysis at the MASHA setup. Prepared by: Abeer M. Attia Supervisor: Lubos Krupa LOGO. Aleksey Novoselov

On the response of LR-115 plastic track detector to tao Ne-ion. S M FARID Department of Physics, Rajshahi University, Rajshahi, Bangladesh

Current Rectification of a Single Charged Conical nanopore. Qi Liu, Peking University Mentor: Prof. Qi Ouyang and Yugangwang

COMPUTATIONAL METHODS AND ALGORITHMS Vol. II - Numerical Algorithms for Inverse and Ill-Posed Problems - A.М. Denisov

Heavy ion fusion energy program in Russia

Chromatography. Mrs. D. MEENA MPharm PA & QA KTPC

Study of monomolecular layers of azobenzene derivative by the scanning probe microscopy

COMPUTER SIMULATION OF THE PROCESSES IN A PAIR OF CR-39 TRACK DETECTORS DURING NEUTRON EXPOSURE

Distillation purification and radon assay of liquid xenon

Characterization of X-ray film base and overhead projector transparency as nuclear track detector

NMR of liquid 3 Не in clay pores at 1.5 K

Influence of Ultraviolet Radiation on Surface Electric Potential of P(VDF-TrFE) Films

Crystalline Surfaces for Laser Metrology

4. Ion chromatography (IC) 4.1. Educational aims and objectives

Electromagnetic modulation of monochromatic neutrino beams

Chemical Reactions Induced by Ionizing and Electron-beam Irradiation in Freon/Water (Ice) Films

Influence of High Magnetic Field on Fusion Reactor Blanket Processes

Track Etch Detectors (TED)

PHYSICOCHEMICAL CHARACTERISTICS OF URANIUM MICROPARTICLES COLLECTED AT NUCLEAR FUEL CYCLE PLANTS. Abstract

ion tracks in cellulose nitrate

CERN LIBRARIES, GENEVA

TEMPERATURE DEPENDENCE OF CURRENT CARRIER S SPIN RELAXATION IN GRAPHITE

Determination of parameters of cascade showers in the water calorimeter using 3D-distribution of Cherenkov light

Laser Supported Detonation in Silica-based Optical Fibers

CHARGED PARTICLE EMISSIONS AND SURFACE MORPHOLOGY OF THE Pd/PdO:Dx AND THE TiDx TARGETS UNDER AN ELECTRON BEAM EXCITATION

Sputtering by Particle Bombardment

Chromatographic Methods: Basics, Advanced HPLC Methods

A POSITION SENSITIVE ALPHA PARTICLE DETECTOR BASED ON A LYSO CRYSTAL AND A MICRO-PIXEL AVALANCHE PHOTODIODE

DEVELOPMENT OF JINR FLNR HEAVY-ION ACCELERATOR COMPLEX IN THE NEXT 7 YEARS

Development of beam delivery systems for proton (ion) therapy

Study of Neutron Induced Modification on Optical Band Gap of CR-39 Polymeric Detector

Atomic force microscopy study of polypropylene surfaces treated by UV and ozone exposure: modification of morphology and adhesion force

The geomagnetic field variations and earthquake activity

PHASE TRANSITIONS. A. Budzanowski

EXCESS HEAT PRODUCTION IN Pd/D DURING PERIODIC PULSE DISCHARGE CURRENT IN VARIOUS CONDITIONS

Cation Exchange HPLC Columns

Tracks of MeV]u 4 Ar ions in Lexan polycarbonate detector

Nucleon Transfer within Distorted Wave Born Approximation

Comparison of Polymer Separation by Size Exclusion Chromatography and Asymmetric Flow Field Flow Fractionation

CHEM 429 / 529 Chemical Separation Techniques

Fusion probability and survivability in estimates of heaviest nuclei production R.N. Sagaidak Flerov Laboratory of Nuclear Reactions, JINR, Dubna, RF

Use of SEC-MALS. (Size Exclusion Chromatography - Multi Angle. Light Scattering) for protein quality and characterization

NEW COMPLEX OF MODERATORS FOR CONDENSED MATTER RESEARCH AT THE IBR-2M REACTOR *

Fabrication of micro-optical components in polymer using proton beam micro-machining and modification

EXPERIMENTAL STUDY OF NEUTRON FIELDS PRODUCED IN PROTON REACTIONS WITH HEAVY TARGETS. Nuclear Physics Institute AS CR, Rez Czech Republic

Activities of the neutron standardization. at the Korea Research Institute of Standards and Science (KRISS)

MOLECULAR DYNAMIC SIMULATION OF WATER VAPOR INTERACTION WITH VARIOUS TYPES OF PORES USING HYBRID COMPUTING STRUCTURES

2007 Fall Nuc Med Physics Lectures

Chapter 13 Nuclear physics

Longer-Lasting Electron-Based Microscopy of Single Molecules in Aqueous Medium

Bimodality and Scaling-Signs of phase transition in Nuclear Multifragmentation? B.Grabez Institute of Physics Zemun

Laser Spectroscopy on Bunched Radioactive Ion Beams

Open Column Chromatography, GC, TLC, and HPLC

Hrant Gulkanyan and Amur Margaryan

Highly charged ion beams applied to fabrication of Nano-scale 3D structures. Sadao MOMOTA Kochi University of Technology

PLASMA-POLYMER MODIFICATION OF BASAL PLANE GRAPHITE SURFACES FOR IMPROVED BIOCOMPATIBILITY

Surface analysis techniques

Half Yearly Exam 2015

A new approach to AFM investigation of buried Al/In x Ga 1-x As/GaAs interfaces and quantum dots

Transcription:

Radiation Measurements 34, 75 (2001). The heavy ions tracks in polymers investigation by means of higheffective liquid chromatography and atomic-force microscopy. A.I.Vilensky a*, O.G. Larionov b, R.V. Gainutdinov a, A.L. Tolstikhina a, V.Ya. Kabanov b D.L. Zagorski a, E.V. Khataibe a, A.N. Netchaev a, B.V. Mchedlishvili a. a Shubnikov Institute of Crystallography of Russian Academy of Science, Leninsky prosp., 59, Moscow, 117333, Russian Federation, b Institute of Physical Chemistry of Russian Academy of Science, Leninsky prosp., 31, Moscow, 117915, Russian Federation Abstract The method of heavy high-energy ions latent tracks structure in polymers investigations have been proposed. This method includes the irradiated polymer preliminary treatment with water, then with week alkali solution for different track area visualization and investigation. The products of polyethylene terephthalate radiolysis from the track areas were investigated by means of inverse-phase chromatography. Atomicforce microscopy was used for polymer investigation. It was shown that the latent track has complicated structure and consists of different areas. For Xe- irradiated PET- sample 3 areas (with diameters 7 nm, 17 nm and 50-150 nm) were found. Such track structure allows to explain the discrepancy between the data, previously obtained by using different methods. Keywords: heavy ions, tracks, polymers, atomic-force microscopy, chromatography *Corresponding Author Alexander Vilensky, Shubnikov Institute of Crystallography RAS, Leninsky prosp., 59, Moscow, 117333, Russia, Fax: (095) 135-10-11; E-mail: track@imb.imb.ac.ru.

2 1.Introduction. During the last years the track membranes (TM), obtained by swift heavy ions irradiation of polymers and by subsequent latent tracks (LT) etching, are widely used in the medicine, biotechnology and in the ecological problems solving. In this connection the detailed study of swift heavy ions tracks structure in polymers is of a big interest for the TM pores structure improvement (pores geometry and selective layer parameters variation, pores sizes scattering diminution and etc.). The polyethylene terephthalate (PET) films are most frequently used for the TM production. It was shown by the studying of LT etching mechanism in PET that the pores formation includes several stages: at the beginning of etching the hillocks at the sample surface are formed on the tracks places. These hillocks are found to be micro-gels (Vilensky and Tolstikhina, 1999a; Vilensky and Tolstikhina, 1999b),. It was previously shown by the exclusion chromatography (EC) that these hillocks consist of cross-linked and destroyed polymer and include the set of oligomers (Vilensky, et al., 1997).The considerable changing of polycarbonate (PC) and PET molecular-weight distribution as a result of heavy ions irradiation were found by EC method. Such molecular mass changing indicate the macromolecule branching and cross-linking (Vilensky, et al., 1997; Vilensky and Zhdanov, 1998). The results on the LT etching cited above and the other literature data (Apel, 1991; Ciesla et al., 1994; Trautmann et al.,1998; Durrani and Bull, 1990; Fleischer et al.,1981; Waligorski et al.,1986; Apel et al., 1997; Smolyansky et al., 1993; Vilensky et al., 1992) show that track has complicated structure. In the heavy high-energy ions tracks in polymer (PET) 2 areas (zones) were found: the core (predominating of destruction) and the cover (predominating of macromolecules cross-linking) (Apel, 1991; Ciesla et al., 1994). On the other hand, it was found that LT in the polycarbonate (CR-39), irradiated by Kr ions with energy 209 MeV, consists of three areas: with sizes 10-20, 50-100 and 100-500 nm respectively (Rozlosnik et al, 1997). But the features and nature of these areas were not determined. It may be suggested, that the polymer tracks etching peculiarities connected with the complicated structure of tracks. So, the object of the present work was the complex investigation of LT etching and LT structure using the high-effective liquid chromatography (HELC) and the atomic-force microscopy (AFM) techniques.

3 2.Experimentals. Samples. The biaxially-oriented PET film with thickness 10 mcm was used. The samples were irradiated with Xe ions (energy 1 MeV/a.m.u, fluence 2 10 9 cm -2 ) (the cyclotron U-400, Flerov Laboratory of Nuclear Reactions of JINR, Dubna). The linear energy loss of Xe ions at the entrance in polymer was about 10 kev/nm. Chemical treatment. In the present work two chemical techniques were used for LT structure and chemical composition investigation: the method of layer-by-layer etching, developed before by one of the authors and the method of swelling. First method consists of consecutive LT areas etching and etching products investigation in solution (Vilensky, et al., 1997; Vilensky and Zhdanov, 1998). The radiolysis products from the core and from the LT area were extracted by water to the full elimination of ones from tracks. After that the radiolysis products from the other track areas were extracted by the combination of etching processes at different temperatures: 15 min at 75 0 C and 1.5 h at 20 0 C (KOH water solution 0.25 mole/l was used). The second method: water treatment of the samples leads to different swelling of different LT areas and to visualization of these areas. Chromatography. The products separation from the liquid solutions and theirs investigation were carried out on the "Millichrom 4" and on the "Millichrom A-02" chromatographs with the column, filled with modified adsorbents: Diabond and Eurospher C 18-5. The separation was carried out in isocratic and in gradient regimes. The acetonitrile water solutions with the different components ratio (from 0 up to 100% of acetonitrile) were used as the eluent. AFM-microscopy. The surface of the polymer samples was investigated by AFM Solver P-47 (NT-MDT, Russia). Resonance regime ( taping mode ) was carried out using silicon cantelivers (lenght 90 mcm, tip radius less then 10 nm, frequency 300-400 khz), working in the air at room temperature. Plane and three-dimensional images of the samples surface relief were obtained. Standard NT-MDT computer programs for size determination and statistic calculation were used. 3. Results and discussions. Fig. 1 demonstrates the obtained track structure, which includes three typical areas. First area. The polymer irradiation with heavy swift Xe ions leads to remarkable changing of the surface morphology. The typical cavities at the surface of irradiated polymer (without any chemical treatment) were found using AFM. The surface density of the cavities corresponds to the fluence of irradiation. These cavities average diameter (D 1 )

4 is equal to 7±1.5 nm. This size corresponds to the value, calculated on the base of absorbed energy value (Durrani and Bull, 1987; Fleischer et al., 1981). The central track area, corresponds to these cavities diameter, can be named as the track core (area 1, Fig. 1). Second area. In this area (area 2,Fig. 1) the destruction processes are predominant. This area was discovered after the irradiated PET exposure in water at least 4 hours; this exposure provides, on the base of HELC data, the complete removing and decomposition of radiolysis products from LT. The radiolysis products, passed into water, were studied by HELC. The typical chromatograms of the irradiated PET radiolysis products, educed after the exposure in water during 15 min, 2h or 4h, are presented on Fig. 3. The chromatograms demonstrate, that the peaks quantity and intensity and spectral ratios are changed with the time. The time of radiolysis products retention on the hydrophobic fixed phase is less than that of terephthalic acid (TPA), i.e. the radiolysis products are more hydrophilic. The kinetic curves of radiolysis products accumulation in water (calculated on the base of HELC) are shown on Fig. 4 (curve 2). It was found that radiolysis products from LT are diffused into water during a few minutes, after that they decomposed with TPA formation (Fig. 4, curve 1). Though these radiolysis products were not exactly identified, we can suppose (on the base of HELC) that they consists of low oligomers with carbonyl, carboxyl and hydroxyl groups. The radiolysis products removing from the LT results to the increasing of the changed area: the cavities diameter, estimated by AFM, increase up to 17±3 nm. (D 2 ). Such area diameter is approximately corresponds to the secondary electrons run (Apel et al., 1997). The D 2 value is in a good agreement with the track sizes, obtained by means of conductometry method on maximum etching rate (Apel, 1991; Apel et al, 1997). Thus, this area with average diameter 17 nm can be named as the destruction area. Third area. Combination of chemical methods (alkali etching), HELC and AFM technique was used at this stage of investigation. The etching products (potassium terephthalate and radiolysis products) from this area were analyzed by HELC method. Fig.5 demonstrates these products accumulation at 20 o C. At the beginning of etching curves 1 and 3 are coincides, and the etching velocity deviation is visible only after 2 hours. This data shows that during first 2h the etching velocities of irradiated and control films are equal. The potassium terephthalate concentration in the solution increases only at the TM pore structure formation (right side of curve 1 on Fig. 5). The accumulation of radiolysis products from the destruction track area is differ: after several minutes of exposure the radiolysis products are turning into the solution, but only after 3h, with the

5 TM pore structure formation, concentration of that products in the solution increases significantly. At the higher temperature the velocity of the radiolysis products accumulation in the solution is much higher. The radiolysis products from tracks accumulation in KOH solution (0.25 mole/l, 75 0 C) is shown on Fig. 6. The curve has S-like character. The lower part of the curve is analogous to curve 2 on Fig. 5 and describes the radiolysis products removing from the track core and from the destruction area (Fig. 1, areas 1 and 2), and also the TM pore structure formation. Subsequent radiolysis products isolation into solution occurs at the track areas etching, where cross-linking is predominate (Fig. 1, area 3; the diameters range, is from 7 nm up to 60 nm). During further etching (diameters range from 60 nm up to 100 nm) the radiation destruction product removing into the solution was not observed. So, according to HELC data, the structure of this area is identical to initial polymer structure. At the beginning of the alkali etching process the swelling took place. AFM demonstrated the formation of hillocks at the polymer surface (Fig. 7). The surface density of these hillocks corresponds to irradiation fluence. It was found, that LT area swelling time till the hillocks formation depends on KOH solution temperature and concentration. After the hillocks appearance theirs size increase from 50 nm up to 150 nm. After that hillocks size decrease and then they disappear. On further etching the straight through channels (pores) with diameter ~7 nm are formed on the places of hillocks. The swelling confirms the cross-linking of the polymer molecules in this area of LT during the irradiation. The diameter D 3 (area 3, Fig. 1) is approximately equal to the diameter of total changed polymer area, that is found in works (Vilensky et al, 1997; Vilensky and Zhdanov, 1998; Smolyansky et al., 1993; Vilensky et al., 1992). Appearance of this big area of cross-linked polymer can be attributed to the blast wave presence at the moment of tracks formation or to the hot hydrogen atoms diffusion (Goldansky et al., 1975; Apel, 1998; Sokolova et al., 1997). Thus, HELC and AFM data show that polymer structure in the track area is more complicated that previously shown. The track structure determines the velocity and peculiarities of etching. Acknowledgements. We would like to express our thanks to A.Yu. Didyk and P.Yu. Apel for their discussions and to ISTC found (Project N 918).

6 References. Apel, P.Yu.,1991. Conducuctometric investigation of track structure in polymers. Chemistry of High Energies; 25, 132-137, (in Russian). Apel, P.Yu.,1998. Doctors thesis, IPC RAS, 190, (in Russian). Apel, P.Yu., Schulz, A., Spohr, R., Trautmann, C. and Vutsadakis, V.,1997. Tracks of very heavy ions in polymers. Nucl. Instrum. Meth. in Phys. Res.; B 131, 55-63. Ciesla, K., Ferain, E., Lagras, R. and Starosta, W.,1994. Investigation of heavy ions track structure in PETF. Intern. Symposium Ionizing Radiation and Polymers, (Abstracts of reports, Guadeloupe), 43. Durrani, S.A. and Bull, R.K.,1987. The Solid State Nuclear Track Detection Principles.(Pergamon Books Ltd.). Fleischer, R.L., Price, P. and Walker R.M.,1975. Nuclear Tracks in Solids. (Univ. of California Press, Berkeley). Goldansky, V.I., Lantsburg, E.Ya. and Yampolsky, Yu.P., 1975.. Hydrodynamic effect during fission fragments passing through condensed matter. JETP Letters; 21, 365-367. (in Russian). Rozlosnik, N., Sajo Bohus, L., Birattari, C., Gadioli, E., Biro, L.P. and Havancsak, K.,1997. Direct observation of latent nuclear tracks in organic material by atomic force microscopy. Nanotechnology; 8, 32-34. Smolyansky, A.S., Zhdanov, G.S., Klinshpot, E.R. and Milinchuk, V.K., 1993. Peculiarities of dimethilformamide sorption in thin PET films, irradiated by Xe-ions. Chemistry of High Energies; 25, 19-23. (in Russian). Sokolova, Yu.D., Machula, A.A., Milinchuk, V.K. and Zhdanov G.S.,1997. On the latent track structure in polymers, irradiated by heavy ions. Colloid. Journ.;59, 395-398. (in Russian).. Trautmann, C., Schwartz, K., Costantini, J.M., Steckenreiter, T. and Toulemonde, M., 1998. Radiation defects in lithium fluoride induced by heavy ions. Nuclear instruments and methods in Physics Research; B 146, 367-378. Vilensky, A.I and Tolstikhina, A.L., 1999a. Etching of tracks of accelerated heavy ions in PET and some physicochemical properties of track membranes. Rus. Chem. Bull.; 48, 1100-1103. (Engl. transl.).

7 Vilensky, A.I and Tolstikhina, A.L., 1999b. Study of pore formation during etching of latent tracks of accelerated heavy ions in PET by atomic force microscope. Rus. Chem. Bull.; 48, 1104-1107. (Engl. transl.). Vilensky, A.I. and Zhdanov, G.S., 1998. Chemical changing of track area in Xeirradiated PET. Chemistry of High Energies; 32, 112-117. (in Russian). Vilensky, A.I., Oleinikov, V.A. and Mchedlishvili, B.V.,1992. Xe-ions track structure investigation in PET. Chemistry of High Energie ; 26, 300-303. (in Russian). Vilensky, A.I, Guryanova, V.V., Nikolsky, E.E., Vlasov, S.V. and Mchedlishvili, B.V.,1997. Polycarbonate film changing during track membrane formation. Chemistry of High Energies; 32, 12-17. (in Russian). Waligorski, M.P.R., Hamm, R.N., and Katz R., 1986.Corrected formula for the distribution of radial dose around the path of a heavy ion. Nucl. Tracks Radiat Meas.; 11, 309-319.

8 Inscriptions to pictures. Fig. 1. The scheme of heavy ion latent track structure: 1 track core (diameter D 1 ); 2 destruction area (D 2 ) ; 3 area of cross-linking (D 3 ), 4- initial polymer Fig. 2. a. AFM image of PET surface irradiated with Xe ions (fluence 2 10 9 cm -2 ). The dark fields corresponds to cavities), b. Cross-section profiles: 1-profile of the surface with the cavity, 2- polymer surface profile. Fig. 3. The chromatograms of water solution radiolysis products, extracted from irradiated PET film. Exposure time in water: a 15 minutes; b 2 hours; c 4 hours (corresponds to TPA). Chromatograph "Milichrom A-02", column with Eurospher C18-5. The eluent is water-acetonitrile (linear gradient 5-100%). Fig. 4. The water-soluble products extraction from irradiated PET film. (S relative peaks area). Curve 1 TPA; curve 2 other radiolysis products. Fig. 5. The accumulation of PET etching products in KOH solution (0,25 mole/l) at 20 0 C. (S relative peaks area). Curve 1 accumulation of TPA from irradiated PET; curve 2 accumulation of radiolysis products from irradiated PET ; curve 3 accumulation of TPA from control (non-irradiated) PET. (Chromatograph "Milichrom 4", column with Diabond C18. The eluent is water). Fig. 6. The accumulation of PET radiolysis products in KOH solution (0,25 mole/l) at 75 0 C. (Chromatograph "Milichrom 4", column with Diabond C18). The arrows denote the pore size. Fig. 7. a- AFM image of irradiated PET surface, after alkali etching (2h at 20 o C). The white fields indicate the hillocks the tracks, visualized after swelling in alkali. b- cross-section profiles: 1-profile of the surface with the hillocks, 2- polymer surface profile.

9 Fig. 1.

10 Fig.2. 1 AU 0.67 1.13 1.60 2.65 3.59 3.98 4.09 6.69 3.04 230nm 280nm 200nm 1 AU 1 2 3 4 5 6 7 мин 0.64 3.96 6.68 1.80 3.15 230nm 280nm 200nm 1 2 3 4 5 6 7 мин 1 AU 0.70 7.00 3.93 230nm 280nm 200nm 1 2 3 4 5 6 7 мин Fig3

11 Fig. 4.

12 50 40 1 S, 30 20 2 10 3 0 0 1 2 3 4 5 6 t, h Fig. 5.

13 6 S,отн 4 2 0 0 20 40 60 80 100 120 140 160 t,мин Fig. 6.

14 Fig. 7 a. Fig. 7 b.