BIPM.RI(II)-K1.F-18, BIPM.RI(II)-K4.F18, CCRI(II)-K3.F-18 and APMP.RI(II)-K3.F-18

Similar documents
BIPM.RI(II)-K1.Am-241, CCRI(II)-K2.Am-241, and COOMET.RI(II)-K2.Am.241

Bureau International des Poids et Mesures (BIPM),

C. Michotte*, G. Ratel* and S. Courte*, T. Dziel #, A. Listkowska #, I. Csete, K. Rózsa, L. Szücs, A. Zsinka, C. Fréchou**, C. Bobin**, S.

G. Ratel 1, C. Michotte 1, M. Sahagia 2, A. Yunoki 3. Abstract

National Physical Laboratory (NPL), UK

G. Ratel*, C. Michotte*, Y. Hino** *BIPM and **NMIJ, Japan

Activity measurements of the radionuclide 153 Sm for the ANSTO, Australia in the ongoing comparison BIPM.RI(II)-K1.Sm-153

The metrology of radioactivity. C. Michotte, BIPM

Bureau International des Poids et Mesures (BIPM), Sèvres. National Institute of Standards and Technology (NIST), USA. Becquerel (LNE-LNHB), France

G. Ratel 1, C. Michotte 1, D. Kryeziu 1, M. Moune 2, A. Iwahara 3. Abstract

The BIPM key comparison database, Aug /10

Activity measurements of the radionuclide 111 In for the LNE-LNHB, France in the ongoing comparison BIPM.RI(II)-K1.In-111

Activity measurements of the radionuclide 99m Tc for the NIST, USA in the ongoing comparison BIPM.RI(II)-K4.Tc-99m. C. Michotte 1, R.

Degrees of equivalence for the key comparison BIPM.RI(I)-K3 between national primary standards for medium-energy x-rays

C. Michotte, G. Ratel, S. Courte and L. Joseph 1 BIPM, Sèvres and 1 Bhabha Atomic Research Centre (BARC), India

Key comparison BIPM.RI(I)-K1 of the air-kerma standards of the LNE-LNHB, France and the BIPM in 60 Co gamma radiation

*BIPM, # CNEA, BARC, $ NRC, **NIM. Abstract

C. Michotte 1, G. Ratel 1, S. Courte 1, Y. Nedjadi 2, C. Bailat 2, L. Johansson 3, Y. Hino 4. Abstract

Summary of the ICRM Life Sciences Working Group Meeting

Activity measurements of the radionuclide 99m Tc for the CNEA, Argentina and the LNMRI/IRD, Brazil in the ongoing comparison BIPM.RI(II)-K4.

Key comparison BIPM.RI(I)-K1 of the air-kerma standards of the NIM, China and the BIPM in 60 Co gamma radiation

Lab i x i u i Lab i x i u i / (mg/kg) / (mg/kg) / (mg/kg) / (mg/kg)

Key comparison BIPM.RI(I)-K7 of the air-kerma standards of the CMI, Czech Republic and the BIPM in mammography x-rays

International comparison of activity measurements of a solution of tritiated water CCRI(II)-K2.H-3

BIPM comparison BIPM.RI(II)-K1.Co-57 of activity measurements of the radionuclide 57 Co. G. Ratel and C. Michotte BIPM

Consistency and confidence: the role of the National Measurement System

BUREAU INTERNATIONAL DES POIDS ET MESURES

Key comparison BIPM.RI(I)-K4 of the absorbed dose to water standards of the METAS, Switzerland and the BIPM in 60 Co gamma radiation

BIPM comparison BIPM.RI(II)-K1.Co-60 of the activity measurements of the radionuclide 60 Co. G. Ratel and C. Michotte BIPM

Final Report for CCRI(II)-S1 13 October Activity measurements of a suite of radionuclides ( 40 K, 137 Cs, 210 Pb, 210 Po, 228 Ra, 232 Th, 234 U,

EUROMET PROJECT FINAL REPORT

Comparisons of the standards for air kerma of the GUM and the BIPM for 60 Co and 137 Cs gamma radiation

G. Ratel and C. Michotte BIPM

The BIPM key comparison database (KCDB): linkage of key comparison results

BIPM comparison BIPM.RI(II)-K1.Y-88 of activity measurements of the radionuclide 88 Y and links for the 2000 regional comparison APMP.RI(II)-K2.

G. Ratel and C. Michotte BIPM

Highlights in the work of the BIPM during 2017

Force Key Comparison EUROMET.M.F-K2. (50 kn and 100 kn) EURAMET Project No 518. Final Report. 14 July Pilot: NPL, United Kingdom

Key comparison BIPM.RI(I)-K3 of the air-kerma standards of the NRC, Canada and the BIPM in medium-energy x-rays

LINKING SIM MASS COMPARISONS TO THE KCRV ON 1 kg. Luis O. Becerra CENAM Querétaro, Qro., Mexico,

CCRI comparison CCRI(II)-K2.I-125 of activity measurements of the radionuclide 125 I. G. Ratel and C. Michotte BIPM

The TDCR method in LSC. P. Cassette Laboratoire National Henri Becquerel CEA/LNE, France

CCRI(II) activity comparison of 241 Pu CCRI(II)-K2.Pu-241

Bureau International des Poids et Mesures

International comparison of extrapolation chamber measurements of the absorbed dose rate in tissue for beta radiation

Comparison of the standards for absorbed dose to water of the ENEA-INMRI (Italy) and the BIPM for 60 Co γ rays

DEVELOPMENT OF A PRIMARY STANDARD IN TERMS OF D w FOR 125 I BRACHYTHERAPY SEEDS

Key comparison BIPM.RI(I)-K3 of the air-kerma standards of the BEV, Austria and the BIPM in medium-energy x-rays

INTERNATIONAL KEY COMPARISON OF MEASUREMENTS OF NEUTRON SOURCE EMISSION RATE ( ) CCRI(III)-K9.AmBe

CCQM-K27.2 Second Subsequent Study: Determination of Ethanol in Aqueous Media Final Report

BIPM comparison BIPM.RI(II)-K1.Am-241 of the activity measurements of the radionuclide 241 Am. G. Ratel and C. Michotte BIPM

Final Report on Key Comparison EUROMET.M.P-K3.a in the Gauge Pressure Range 50 kpa to 1000 kpa. May 2005

Final Report. APMP.EM-K4.1 APMP Key Comparison of Capacitance at 10 pf


Metrology for Molecular Radiotherapy MetroMRT V. Smyth (coordinator) Lena Johansson, Andrew Fenwick, Kelley Ferreira et al.

Final report EURAMET project 813 1/46

Sampling based on Bayesian statistics and scaling factors

EUROMET Project 702 EUROMET.M.D-K4

BIPM comparison BIPM.RI(II)-K1.Sn-113 of activity measurements of the radionuclide 113 Sn. G. Ratel and C. Michotte BIPM

Final report on CCQM-K36.1 with erratum

BIPM comparison BIPM.RI(II)-K1.Eu-155 of the activity measurements of the radionuclide 155 Eu. G. Ratel and C. Michotte BIPM

The ITS-90 after definition of neon isotopic reference composition: extent of the isotopic effect tested on previous inter-comparison results

A comparison of primary platinum-iridium kilogram mass standards among eighteen European NMIs

Referensdosimetri. Crister Ceberg Medical Radiation Physics Lund University Sweden

Bureau International des Poids et Mesures

Bureau International des Poids et Mesures

Common Test. Quiz. letter from their parent providing a valid explanation for the absence.

FINAL REPORT. European co-operation for Accreditation (EA) Interlaboratory Comparison IR3: Calibration of a Radiation Protection Dosimeter

Key comparison BIPM.RI(I)-K3 of the air-kerma standards of the PTB, Germany and the BIPM in medium-energy x-rays

Force Key Comparison CCM.F-K4.a and CCM.F-K4.b for 4 MN and 2 MN Forces. Final Report. T.W. Bartel NIST Mass and Force Group U.S.A.

Measurement & Uncertainty - Basic concept and its application

Proficiency Test: Non-destructive Assay of 220 liters Waste Drums by Gamma Assay Systems (an ENTRAP initiative)

Measurement & Uncertainty - Concept and its application

AFRIMETS. Supplementary Comparison Programme. Calibration of Gauge Blocks. by Mechanical Comparison Method AFRIMETS.L S3.

Final Report on APMP.M.M-K4.1 - Bilateral Comparison of 1 kg Stainless Steel Mass Standards between KRISS and A*STAR

CALIBRATING GPS WITH TWSTFT FOR ACCURATE TIME TRANSFER

Key comparison BIPM.RI(I)-K2 of the air-kerma standards of the PTB, Germany and the BIPM in low-energy x-rays

Local time scale at PTB UTC(PTB) Ali Al-masoudi, Stephan Falke, Sebastian Häfner, Stefan Vogt, Christian Lisdat

Final Report CCM.V-K2 Comparison

Final Report on COOMET Key Comparison of Capacitance at 10 pf (COOMET.EM-K4)

Final Report. CCEM Comparison of 10 pf Capacitance Standards. Anne-Marie Jeffery Electricity Division NIST May 2000 Revised March 2002

Final Report On COOMET Vickers PTB/VNIIFTRI Key Comparison (COOMET.M.H- K1.b and COOMET.M.H- K1.c)

THE SUPPORT OFFERED BY THE ROMANIAN PRIMARY ACTIVITY STANDARD LABORATORY TO THE NUCLEAR MEDICINE FIELD *

National Physical Laboratory Hampton Road Teddington Middlesex United Kingdom TW11 0LW

Work Programme. of the International Bureau of Weights and Measures. for the four years Comité international des poids et mesures

How do you really know what the temperature is? Michael de Podesta

Introduction. Martin J. T. Milton. Director of the BIPM. Monday 27th June 2016

FINAL REPORT. RMO Key Comparison EUROMET.EM-K2 Comparison of Resistance Standards at 10 M and 1 G. Beat Jeckelmann and Markus Zeier

C2-05: Creation of national standards for some emerging pharmaceutical radionuclides to ensure the radioprotection of patients and medical staffs

Report from TCTF/TCL JWG on Optical Frequency Metrology

CCQM-P28: An international comparison of ground-level ozone reference standards

abstractnumber.doc The Support Offered by the Romanian Primary Activity Standard Laboratory to the Nuclear Medicine Field

Comparison of national air kerma standards for ISO 4037 narrow spectrum series in the range 30 kv to 300 kv

International Committee for Radionuclide Metrology ICRM. ICRM NEWSLETTER Issue 29

Key Comparisons, the MRA and CMCs: An International Measurement Infrastructure. Robert Wielgosz. Bureau International des Poids et Mesures

Bureau International des Poids et Mesures

Recent Primary Standardisations and Traceability in Nuclear Medicine. Lena Johansson, NPL Radioactivity Group

Measurement of the Activity Concentration of the Radionuclide Am-241 in a Solution COOMET PROJECT 359/RU/06

19:00 21:30 Registration and reception at Hotel ETAP Altinel. Welcome

EURAMET supplementary comparison of ambient dose equivalent H*(10) in 137 Cs and ISO Narrow Beam Series N-60 x-ray beams at low dose rates

Transcription:

BIPM.RI(II)-K1.F-18, BIPM.RI(II)-K4.F18, CCRI(II)-K3.F-18 and APMP.RI(II)-K3.F-18 MEASURAND : Equivalent activity of 18 F Key comparison BIPM.RI(II)-K1.F-18 result of measurement carried out in the SIR for the sample submitted by laboratory i Lab i x i u i Date of / kbq / kbq measurement IRA 15312 57 2001-09-21 BEV 15390 160 2002-11-12 CIEMAT 15216 97 2004-05-13 PTB 15316 50 2005-04-13 LNE-LNHB 15203 62 2010-07-05 Key comparison BIPM.RI(II)-K4.F-18 result of measurement carried out in the SIR for the sample submitted by laboratory i Lab i x i u i Date of / kbq / kbq measurement VNIIM 15197 97 June 2014 NPL 15311 52 Sept. 2014 ENEA-INMRI 15368 49 Oct. 2014 NMISA 15328 96 Nov. 2015 The BIPM key comparison database, December 2016 1/5

Key comparison CCRI(II)-K3.F-18 result of measurement carried out at laboratory i converted to the equivalent activity through the NPL Lab i x i u i Measurement / kbq / kbq report date ANSTO 15150 240 2001-03-15 CMI-IIR 15010 120 2001-03-29 NIST 14670 160 2001-03-21 Key comparison APMP.RI(II)-K3.F-18 result of measurement carried out at laboratory i converted to the equivalent activity through the NPL Lab i x i u i Measurement / kbq / kbq report date INER 15130 150 2001-01-11 The BIPM key comparison database, December 2016 2/5

BIPM.RI(II)-K1.F-18, BIPM.RI(II)-K4.F18, CCRI(II)-K3.F-18 and APMP.RI(II)-K3.F-18 MEASURAND : Equivalent activity of 18 F Key comparison BIPM.RI(II)-K1.F-18 Key comparison reference value: the SIR reference value for this radionuclide x R is 15 276 kbq, with a standard uncertainty u R = 24 kbq (see Final Report). The value xi is the equivalent activity for laboratory i. The degree of equivalence of each laboratory with respect to the reference value is given by a pair of terms: D i = (x i - x R ) where w i, its expanded uncertainty (k = 2), both expressed in MBq, and U i = 2[(1-2/n )u i 2 + (1/n 2 )Su i 2 ] 1/2 where w i is the weight of laboratory i contributing to the calculation of x R. Linking BIPM.RI(II)-K4.F-18 to BIPM.RI(II)-K1.F-18 The value x i is the SIRTI equivalent activity for laboratory i participant in BIPM.RI(II)-K4.F-18 multiplied by the linking factor to BIPM.RI(II)-K1.F-18 (see Final Report). The degree of equivalence of laboratory i participant in BIPM.RI(II)-K4.F-18 with respect to the key comparison reference value is given by a pair of terms: D i = (x i - x R ) and U i, its expanded uncertainty (k = 2), both expressed in MBq. The approximation U i = 2(u i 2 + u R 2 ) 1/2 is used in the following table as none of these laboratories contributed to the KCRV. Linking CCRI(II)-K3.F-18 to BIPM.RI(II)-K1.F-18 The value x i is the equivalent activity for laboratory i participant in CCRI(II)-K3.F-18 having been normalized to the value of the NPL and the LNE-LNHB combined as the link. The degree of equivalence of laboratory i participant in CCRI(II)-K3 with respect to the key comparison reference value is given by a pair of terms: D i = (x i - x R ) and U i, its expanded uncertainty (k = 2), both expressed in MBq. The approximation U i = 2(u i 2 + u R 2 ) 1/2 is used as none of these laboratories contributed to the computation of the key comparison reference value as none of these laboratories contributed to the KCRV. The BIPM key comparison database, December 2016 3/5

Linking APMP.RI(II)-K3.F-18 to BIPM.RI(II)-K1.F-18 The value x i is the equivalent activity for laboratory i participant in APMP.RI(II)-K3.F-18 having been normalized to the value of the NPL and the LNE-LNHB combined as the link. The degree of equivalence of laboratory i participant in APMP.RI(II)-K3.F-18 with respect to the key comparison reference value is given by a pair of terms: D i = (x i - x R ) and U i, its expanded uncertainty (k = 2), both expressed in MBq. The approximation U i = 2(u i 2 + u R 2 ) 1/2 is used as this laboratory did not contribute to the computation of the key comparison reference value as none of these laboratories contributed to the KCRV. These statements make it possible to extend the BIPM.RI(II)-K1.F-18 matrices of equivalence to all participants in the CCRI(II)-K3.F-18, the APMP.RI(II)-K3.F-18 and the BIPM.RI(II)-K4.F-18 comparisons. Degrees of Equivalence between BIPM.RI(II)-K1.F-18, BIPM.RI(II)-K4.F-18, CCRI(II)-K3.F-18 and APMP.RI(II)-K3.F-18 Lab i D i U i / MBq IRA 0.04 0.10 BEV 0.11 0.32 CIEMAT -0.06 0.18 PTB 0.04 0.09 LNE-LNHB -0.07 0.11 VNIIM -0.08 0.20 NPL 0.04 0.11 ENEA-INMRI 0.09 0.11 NMISA 0.05 0.20 ANSTO -0.13 0.48 CMI-IIR -0.27 0.24 NIST -0.61 0.32 INER -0.15 0.30 The BIPM key comparison database, December 2016 4/5

[D i = (x i - x R )] / (MBq) [D i / x R ] / (kbq / MBq) BIPM.RI(II)-K1.F-18, BIPM.RI(II)-K4.F-18, CCRI(II)-K3.F-18 and APMP.RI(II)-K3.F-18 Degrees of equivalence for equivalent activity of 18 F 1.0 65 0.8 52 0.6 39 0.4 26 0.2 13 0.0 0-0.2-13 -0.4-26 -0.6-39 -0.8-52 -1.0 IRA BEV CIEMAT PTB LNE- LNHB VNIIM NPL ENEA- INMRI NMISA ANSTO CMI-IIR NIST INER -65 Red diamonds: participants in BIPM.RI(II)-K1.F-18 Pink squares: participants in BIPM.RI(II)-K4.F-18 Blue circles: participants in CCRI(II)-K3.F-18 only Green triangle: participant in APMP.RI(II)-K3.F-18 only Note: One interval of 0.2 MBq on the y axis represents approximately 1.3 % of the key comparison reference value. Right-hand axis shows approximate values only. The BIPM key comparison database, December 2016 5/5