MINIMUM QUALITY CONTROL STANDARDS MQCS-V (VERSION 5, JUNE 2004) to Q 29

Similar documents
Annex 1 to Recommendation 9 (JCOMM-III)

WORLD METEOROLOGICAL ORGANIZATION THE WMO TABLE DRIVEN CODES: THE 21 ST CENTURY UNIVERSAL OBSERVATION CODES

Plot manual. Synop of a landstation The basic form of the SYNOP bulletin for a landstation is: Plotmanual 1

Global Collecting Centres for Marine Climatological Data. Annual Report 2006

Weather observations from Tórshavn, The Faroe Islands

DMI Report Weather observations from Tórshavn, The Faroe Islands Observation data with description

REPORT OF THE INSTRUMENT STANDARDS TASK TEAM ACTIONS PROPOSED

Table of Contents DBCP Buoy Monitoring Statistics... 1

CREX Table D List of common sequences

Global NWP Index documentation

Synoptic Code Symbols with Range of Values

Worksheets for GCSE Mathematics. Algebraic Expressions. Mr Black 's Maths Resources for Teachers GCSE 1-9. Algebra

Technical Report DMI SYNOP AWS Summit. Data status March Ellen Vaarby Laursen. SYNOP weather station Summit.

The following is a decode of the mandatory portion of the dropsonde report:

MANMAR. Manual of Marine Weather Observations

APPENDIX G-7 METEROLOGICAL DATA

Practical help for compiling CLIMAT Reports

Worksheet Week 4 Solutions

Guidelines on Quality Control Procedures for Data from Automatic Weather Stations

Worksheets for GCSE Mathematics. Quadratics. mr-mathematics.com Maths Resources for Teachers. Algebra

REPORT BY THE TASK TEAM ON INSTRUMENTS STANDARDS (TT-IS) (Submitted by Robert Luke, Chairperson, TT-IS)

Data Rescue, QC and a metadatabase: FCiências.ID's contribution to WP3

Precipitation type detection Present Weather Sensor

Data Quality Assurance System. Hong Kong, China

control of. Quality. Laust. sholm Wang. Copenhagen. page 1 of 14

REGIONAL SPECIALIZED METEOROLOGICAL CENTRE (RSMC), EXETER, VOS MONITORING REPORT. (Submitted by Colin Parrett (United Kingdom), RSMC, Exeter)

ARUBA CLIMATOLOGICAL SUMMARY 2014 PRECIPITATION

Earth Networks ENcast 6- Day Hourly Lat- Lon Forecast Feed

Variations. ECE 6540, Lecture 02 Multivariate Random Variables & Linear Algebra

REGIONAL SPECIALISED METEOROLOGICAL CENTRE (RSMC), EXETER, VOS MONITORING REPORT. (Submitted by Colin Parrett (United Kingdom), RSMC Exeter)

III A-PROPATH: Moist Air

10.1 Three Dimensional Space

Secondary 3H Unit = 1 = 7. Lesson 3.3 Worksheet. Simplify: Lesson 3.6 Worksheet

Eureka Lessons for 6th Grade Unit FIVE ~ Equations & Inequalities

Principles of Food and Bioprocess Engineering (FS 231) Solutions to Example Problems on Psychrometrics

Scarborough Tide Gauge

BUFR Table D - List of common sequences

Mini Environmental Quality Meter

Grover s algorithm. We want to find aa. Search in an unordered database. QC oracle (as usual) Usual trick

Climate Change Indices By: I Putu Santikayasa

Lesson 24: True and False Number Sentences

LIST OF AMENDMENTS TO MANUAL ON CODES

Computation of zonal (u) and meridional (v) components. Useful websites.

QUALITY MANAGEMENT IN SURFACE, CLIMATE AND UPPER-AIR OBSERVATIONS IN CHINA

Allocation of percentage Marks Practical rd February, st March, th March nd March

Purdue University Meteorological Tool (PUMET)

5) Which sum is rational?

AWS BUFR representation of nominal values

Accounting for non-gaussian observation error

One sine wave is 7.64 minutes peak to peak variation. Two sine waves is 9.86

GaN and GaN/AlGaN Heterostructure Properties Investigation and Simulations. Ziyang (Christian) Xiao Neil Goldsman University of Maryland

Section 5: Quadratic Equations and Functions Part 1

Table 1-2. TMY3 data header (line 2) 1-68 Data field name and units (abbreviation or mnemonic)

Electric Field and Electric Potential (A)

Portugal. Instituto de Meteorologia

NAVIGATION (1) GENERAL NAVIGATION

RIHMI contribution to ERA-CLIM2 WP4. By Alexander Sterin (RIHMI-WDC, Obninsk, Russia)

Construction and Interpretation of Weather Station Models

CUTTING Shadows SOME CUTOUT DIALS FOR YOUR AMUSEMENT. ALL YOU NEED ARE SOME SCISSORS, AND YOUR LATITUDE, AND LONGITUDE.

Diffusive DE & DM Diffusve DE and DM. Eduardo Guendelman With my student David Benisty, Joseph Katz Memorial Conference, May 23, 2017

Vantage PRO2 Quick. Reference Guide

Solving Fuzzy Nonlinear Equations by a General Iterative Method

Thermodynamic Cycles

Modelling of Solidification and Melting in a Latent Heat Storage

Regression Models for Forecasting Fog and Poor Visibility at Donmuang Airport in Winter

Terms of Use. Copyright Embark on the Journey

Quality Control of Meteorological Observations at Fleet Numerical Meteorology and Oceanography Center

Rational Expressions and Functions

London Heathrow Field Site Metadata

Bryan Butler. National Radio Astronomy Observatory. November 23, 1998

USE OF SURFACE MESONET DATA IN THE NCEP REGIONAL GSI SYSTEM

STUDY OF GAS-LIQUID MASS TRANSFER IN A GRID STIRRED TANK

SECTION 7: STEADY-STATE ERROR. ESE 499 Feedback Control Systems

Quick Reference Guide

Communication and data formats

Arun Platform Tide Gauge

OCEAN & SEA ICE SAF CDOP2. OSI-SAF Metop-A IASI Sea Surface Temperature L2P (OSI-208) Validation report. Version 1.4 April 2015

TSOKOS READING ACTIVITY Section 7-2: The Greenhouse Effect and Global Warming (8 points)

ANALYSIS OF THE MICROCLIMATE OF SÃO CRISTÓVÃO AND ITS INFLUENCE IN HEATING SYSTEMS, VENTILATING AND AIR CONDITIONING (HVAC)

Patterns of soiling in the Old Library Trinity College Dublin. Allyson Smith, Robbie Goodhue, Susie Bioletti

Lecture No. 5. For all weighted residual methods. For all (Bubnov) Galerkin methods. Summary of Conventional Galerkin Method

Re-examination of the Daily Number of Sunspot Groups for the Royal Greenwich Observatory ( )

Mathematics Ext 2. HSC 2014 Solutions. Suite 403, 410 Elizabeth St, Surry Hills NSW 2010 keystoneeducation.com.

Three-dimensional Structure in Midlatitude Cyclones. ATMS 370 Due Friday, March 9, 2018

Explanation and decode for code figures used in the Wokingham 0900 and 1500 GMT observations

Name 28-MAY-08. FA RP 1 Mr. Chase. 1. Which weather-station model shows an air pressure of millibars?

Snow Analysis for Numerical Weather prediction at ECMWF

Systems of Linear Equations

A description of these quick prepbufrobs_assim text files is given below.

BUFR format in a nutshell

Property Testing and Affine Invariance Part I Madhu Sudan Harvard University

Coulomb s Law and Coulomb s Constant

The Impact of Observational data on Numerical Weather Prediction. Hirokatsu Onoda Numerical Prediction Division, JMA

SMOS NRT BUFR specification

Module 7 (Lecture 25) RETAINING WALLS

BLOOM PUBLIC SCHOOL Vasant Kunj, New Delhi Lesson Plan Class: V Subject: SOCIAL SCIENCE. Month: July No of Periods: 9 TTT: 4 WT: 5

Archimedes Principle

Extreme value statistics: from one dimension to many. Lecture 1: one dimension Lecture 2: many dimensions

Complimentary assessment of forecast performance with climatological approaches

The Upper Air Database in the Research Data Archive at NCAR INTRODUCTION...1 UPPER AIR DATASET DESCRIPTIONS...3 REFORMATTING AND STANDARDIZATION...

Transcription:

MINIMUM QUALITY CONTROL STANDARDS MQCS-V (VERSION 5, JUNE 2004) NOTE See specification for quality control Indicators Q 1 to Q 29 at the end of this appendix Δ = space (ASCII 32) 1 i 3 5, Δ Correct manually otherwise Δ T 2 AAAA valid year Correct manually otherwise reject 3 MM 01-12 Correct manually otherwise reject 4 YY valid day of month Correct manually otherwise reject 5 GG 00-23 Correct manually otherwise reject 6 Q c 1, 3, 5, 7 Q c = Δ Correct manually and Q = 5, otherwise Q 20 = 4 20 Q = 2 20 7 L a L a L a 000-900 Correct manually and Q = 5, otherwise Q 20 20 = 4 L a L a L a = ΔΔΔ Q = 2 20 8 L o L o L o L o 0000-1800 Correct manually and Q = 5, otherwise Q 20 20 = 4 L o L o L o L o = ΔΔΔΔ Q = 2 20 L a L a L a = L o L o L o L o = ΔΔΔ(Δ) Correct manually otherwise reject Time sequence checks Change in latitude > 0.7 o /hr Correct manually otherwise Q 20 = 3 Change in longitude > 0.7 o /hr Correct manually otherwise Q 20 = 3 when lat. 00-39.9 Change in longitude > 1.0 o /hr Correct manually otherwise Q 20 = 3 when lat. 40-49.9 Change in longitude > 1.4 o /hr Correct manually otherwise Q 20 = 3 when lat. 50-59.9 Change in longitude > 2.0 o /hr Correct manually otherwise Q 20 = 3 when lat. 60-69.9 Change in longitude > 2.7 o /hr Correct manually otherwise Q 20 = 3 when lat. 70-79.9 9 No checking 10 h 0-9 Correct manually and Q = 5, otherwise Q 1 1 = 4 h = Δ Q = 9 1 11 VV 90-99 Correct manually and Q = 5, otherwise Q 2 2 = 4 VV = ΔΔ Q = 9 2 12 N 0-9, Δ Correct manually and Q = 5, otherwise Q 3 3 = 4 N < Nh Correct manually and Q = 5, otherwise Q 3 3 = 2 13 dd 00-36, 99 Correct manually and Q 4 = 5, otherwise Q 4 =4 dd = ΔΔ Q 4 = 9 dd versus ff dd = 00, ff 00 Correct manually and Q 4 or Q 5 = 5 otherwise Q 4 = Q 5 = 2 dd 00, ff = 00 Correct manually and Q 4 or Q 5 = 5 otherwise Q 4 = Q 5 = 2

p. 2 14 i w 0, 1, 3, 4 Correct manually, otherwise Q 5 = Q 29 = 4 15 ff > 80 knots Correct manually and Q 5 = 5, otherwise Q 5 = 3 ff = ΔΔ Q 5 = 9 16 s n 0, 1 Correct manually, otherwise Q 6 = 4 17 TTT = ΔΔΔ Q 6 = 9 If -25 > TTT >40 then when Lat. < 45.0 TTT < -25 Q 6 = 4 TTT > 40 Q 6 = 3 when Lat. 45.0 TTT < -25 Q 6 = 3 TTT > 40 Q 6 = 4 TTT versus humidity parameters TTT < WB (wet bulb) Correct manually and Q 6 = 5, otherwise Q 6 =Q 19 = 2 TTT < DP (dew point) Correct manually and Q 6 = Q 7 = 5, otherwise Q 6 = Q 7 = 2 18 s t 0, 1, 2, 5, 6, 7 Correct manually, otherwise Q 7 =4 19 DP > WB Correct manually and Q 7 = 5, otherwise Q 7 =Q 19 = 2 DP > TTT Correct manually and Q 7 = 5, otherwise Q 7 = Q 6 =2 WB = DP = ΔΔΔ Q 7 =Q 19 = 9 20 930 > PPPP > 1050 hpa Correct manually and Q 8 = 5, otherwise Q 8 = 3 870 > PPPP > 1070 hpa Correct manually and Q 8 = 5, otherwise Q 8 = 4 PPPP = ΔΔΔΔ Q 8 = 9 21 ww = 22-24, 26, 36-39, 48, Correct manually and Q 9 = 5, otherwise Q 9 = 4 49, 56, 57, 66-79, 83-88 93-94 Correct manually and Q 9 = 5, otherwise Q 9 = 3 and latitude <20 o if i x = 7: w a w a = 24-25, 35, 47-48, Correct manually and Q 9 = 5, otherwise 54-56, 64-68, 70-78, 85-87 Q 9 = 4 and latitude <20 o 22, 23 W or W 1 2 = 7 and latitude <20o Correct manually and Q 9 = 5, otherwise Q 9 = 4 W 1 < W 2 Correct manually and Q 9 = 5, otherwise Q 9 = 2 W 1 = W = ww = ΔΔΔΔ 2 Q 9 = 9 24-27 N = 0, and N h C L C M C H 0000 Correct manually and Q 3 = 5, otherwise Q 3 = 2 N = Δ, and N h C L C C ΔΔΔΔ Correct manually and Q 3 = 5, otherwise Q 3 = 2 M H N = 9, and not (N h =9 and Correct manually and Q 3 = 5, otherwise Q 3 = 2 C L C C H ΔΔΔ M N=Δ, and N h C L C M C H =ΔΔΔΔ Q 3 = 9 28 s n 0, 1 Correct manually otherwise Q 10 = 4 29 T w T w T w = ΔΔΔ Q 10 = 9 if -2.0 > T w T w T w > 37.0 then when Lat. < 45.0 T w T w T w < -2.0 Control manually and Q 10 = 5, otherwise Q 10 = 4 T w T w T w > 37.0 Control manually and Q 10 = 5, otherwise Q 10 = 3 when Lat. 45.0 T w T w T w < -2.0 Control manually and Q 10 = 5, otherwise Q 10 = 3 T w T w T w > 37.0 Control manually and Q 10 = 5, otherwise Q 10 = 4

p. 3 30 Indicator 0-7, Δ Correct manually, otherwise Δ 31 Indicator 0-9, Δ Correct manually, otherwise Δ 32 20 < P w P w < 30 Q 11 = 3 P w P w 30 and 99 Q 11 = 4 P w P w = ΔΔ Q 11 = 9 33 35< H w H w < 50 Q 12 = 3 H w H w 50 Q 12 = 4 H w H w = ΔΔ Q 12 = 9 34 d w1 d w1 00-36, 99 Correct manually and Q 13 = 5, otherwise Q 13 = 4 swell 1 = swell 2 = Δ Q 13 = 9 35 25 < P w1 P w1 < 30 Q 13 = 3 P w1 P w1 30 and 99 Q 13 = 4 36 35 < H w1 H w1 < 50 Q 13 = 3 H w1 H w1 50 Q 13 = 4 37 I s 1-5, Δ Correct manually, otherwise Δ 38 E s E s 00-99, ΔΔ Correct manually, otherwise ΔΔ 39 R s 0-4, Δ Correct manually, otherwise Δ 40 Source 0-6 Correct manually, otherwise Δ 41 Platform 0-9 Correct manually, otherwise Δ 42 No call sign Insert manually, mandatory entry 43 No country code Insert manually 44 No Quality Control 45 Q 0-6, 9 Correct manually, otherwise Δ 46 i x 1-7 Correct manually, otherwise Δ 47 i = 0-2 and RRR = 000, ΔΔΔ Correct manually, otherwise Q R 14 = 4 i = 3 and RRR ΔΔΔ R Correct manually, otherwise Q 14 = 2 i R = 4 and RRR ΔΔΔ Correct manually, otherwise Q 14 = 2 i R 0-4 Correct manually, otherwise Q 14 = 4 48 RRR 001-999 and i R = 1, 2 Correct manually and Q 14 = 5, otherwise Q 14 = 2 49 t R 0-9, Δ Correct manually and Q 14 = 5, otherwise Q 14 = 4 50 s w 0, 1, 2, 5, 6, 7 Correct manually, otherwise Q 19 = 4 51 WB < DP Correct manually and Q 19 = 5, otherwise Q 19 =Q 7 =2 WB = ΔΔΔ Q 19 = 9 WB > TTT Correct manually and Q 19 = 5, otherwise Q 19 =Q 6 = 2 52 a 0-8 Correct manually and Q 15 = 5, otherwise Q 15 = 4 a = 4 and ppp 000 Correct manually and Q 15 or Q 16 = 5, otherwise a =1,2,3,6,7,8 and ppp=000 Q 15 =Q 16 =2 Correct manually and Q 15 or Q 16 = 5, otherwise Q 15 =Q 16 = 2 a = Δ Q 15 = 9 53 250 ppp > 150 Correct manually and Q 16 = 5, otherwise Q 16 = 3 ppp > 250 Correct manually and Q 16 = 5 otherwise Q 16 = 4 ppp = ΔΔΔ Q 16 = 9 54 D s 0-9 Correct manually and Q 17 = 5, otherwise Q 17 = 4 D s = Δ Q 17 = 9 55 v s 0-9 Correct manually and Q 18 = 5, otherwise Q 18 = 4 v s = Δ Q 18 = 9 56 d w2 d w2 00-36, 99, ΔΔ Correct manually and Q 13 = 5, otherwise Q 13 = 4 57 25 < P w2 P w2 < 30 Q 13 = 3 P w2 P w2 30 and 99 Q 13 = 4 58 35 < H w2 H w2 < 50 Q 13 = 3 H w2 H w2 50 Q 13 = 4 59 c i 0-9, Δ Correct manually, otherwise Δ 60 S i 0-9, Δ Correct manually, otherwise Δ

p. 4 61 b i 0-9, Δ Correct manually, otherwise Δ 62 D i 0-9, Δ Correct manually, otherwise Δ 63 z i 0-9, Δ Correct manually, otherwise Δ 86 Minimum Quality Control 1= MQCS-I (Original version, Feb. 1989) CMM-X Standards (MQCS) version identification 2= MQCS-II (Version 2, March 1997) CMM-XII 3= MQCS-III (Version 3, April 2000) SGMC-VIII 4= MQCS-IV (Version 4, June 2001) JCOMM-I 5= MQCS-V (Version 5, July 2004) ETMC-I 87 HDG 000-360 Correct manually and Q 22 = 5, otherwise Q 22 = 4 HDG = ΔΔΔ Q 22 = 9 88 COG 000-360 Correct manually and Q 23 = 5, otherwise Q 23 = 4 COG = ΔΔΔ Q 23 = 9 89 SOG 00-99 Correct manually and Q 24 = 5, otherwise Q 24 = 4 SOG = ΔΔ Q 24 = 9 SOG > 33 Correct manually and Q 24 = 5, otherwise Q 24 = 3 90 SLL 00-99 Correct manually and Q 25 = 5, otherwise Q 25 = 4 SLL = ΔΔ Q 25 = 9 SLL > 32 Correct manually and Q 25 = 5, otherwise Q 25 = 3 91 s L 0,1 Correct manually and Q 26 = 5, otherwise Q 26 = 4 S L =Δ Q26=9 hh 00 99 Correct manually and Q 27 = 5, otherwise Q 27 = 4 hh = ΔΔ Q 27 = 9 hh >= 13 Correct manually and Q 27 = 5, otherwise Q 27 = 3 hh < -01 Correct manually and Q 27 = 5, otherwise Q 27 = 4 92 RWD 000-360, 999 Correct manually and Q 28 = 5, otherwise Q 28 = 4 RWD = ΔΔΔ Q 28 = 9 93 RWS 000-999 Correct manually and Q 29 = 5, otherwise Q 29 = 4 RWS = ΔΔΔ Q 29 = 9 RWS > 110 kts Correct manually and Q 29 = 5, otherwise Q 29 = 3 RWD versus RWS RWD = 000, RWS 000 RWD 000, RWS = 000 Correct manually and Q 28 or Q 29 = 5, otherwise Q 28 = Q 29 = 2 Correct manually and Q 28 or Q 29 = 5, otherwise Q 28 = Q 29 = 2

p. 5 Specifications for quality control Indicators Q 1 to Q 29 0 No quality control (QC) has been performed on this element 1 QC has been performed; element appears to be correct 2 QC has been performed; element appears to be inconsistent with other elements 3 QC has been performed; element appears to be doubtful 4 QC has been performed; element appears to be erroneous 5 The value has been changed as a result of QC 6 reserved for GCC 7 reserved for GCC 8 Reserve 9 The value of the element is missing