EFFICIENCY CALIBRATION STUDIES FOR GAMMA SPECTROMETRIC SYSTEMS: THE INFLUENCE OF DIFFERENT PARAMETERS

Similar documents
THE RESPONSE FUNCTION OF ISOCART (ORTEC) GAMMA-RAY SPECTROMETRY SYSTEM USING MONTE CARLO SIMULATIONS *

EXPERIMENTAL DETERMINATION OF THE URANIUM ENRICHMENT RATIO

Detection efficiency of a BEGe detector using the Monte Carlo method and a comparison to other calibration methods. Abstract

ENERGY PEAK STABILITY WITH COUNT RATE FOR DIGITAL AND ANALOG SPECTROMETERS

Collimated LaBr 3 detector response function in radioactivity analysis of nuclear waste drums

XRF APPLICATION FOR DIFFUSION STUDIES IN RADIOACTIVE WASTE CEMENTED MATRIX

COMPARATIVE STUDY OF PIGE, PIXE AND NAA ANALYTICAL TECHNIQUES FOR THE DETERMINATION OF MINOR ELEMENTS IN STEELS

GAMMA RAY SPECTROSCOPY FOR ARTIFICIAL CONTAMINATION EFFECTS EVALUATION IN LUMINISCENCE DATING OF ARTEFACTS FROM LOW DEPTH LAYERS IN SOUTHERN ROMANIA *

ISOCS / LabSOCS. Calibration software for Gamma Spectroscopy

REFERENCE SOURCES FOR THE CALIBRATION OF THE AUTOCORRELATION SINGLE-CRYSTAL SCINTILLATION TIME SPECTROMETER

ITU-Nuclear Safeguards and Security Unit

arxiv:nucl-ex/ v2 21 Jul 2005

European Project Metrology for Radioactive Waste Management

Workshop on Understanding and Evaluating Radioanalytical Measurement Uncertainty November The Romanian underground laboratory

Compton suppression spectrometry

Practical Solutions to Radioactive Waste Characterization

Seaborg s Plutonium?

*Corresponding author,

AMS MEASUREMENTS OF DEUTERIUM CAPTURED IN TUNGSTEN LAYERS DEPOSITED BY MAGNETRON SPUTTERING

DESIGN, DEVELOPMENT AND TESTING OF AN AUTOMATED SEGMENTED GAMMA SCANNER FOR MEASURING NUCLEAR POWER STATION RADIOACTIVE WASTE

PRACTICAL GAMMA SPECTROSCOPY ASSAY TECHNIQUES FOR LARGE VOLUME LOW-LEVEL WASTE BOXES

EFFICIENCY SIMULATION OF A HPGE DETECTOR FOR THE ENVIRONMENTAL RADIOACTIVITY LABORATORY/CDTN USING A MCNP-GAMMAVISION METHOD

The Use of Self-Induced XRF to Quantify the Pu Content in PWR Spent Nuclear Fuel

Basic hands-on gamma calibration for low activity environmental levels

RADON EQUILIBRIUM MEASUREMENT IN THE AIR *

Preparation of Standard Source as a Petri Dish for Plant by Using

Gamma-Spectrum Generator

Non-Destructive Assay Applications Using Temperature-Stabilized Large Volume CeBr Detectors 14277

International Journal of Scientific & Engineering Research, Volume 5, Issue 3, March-2014 ISSN

Depth Distribution of H-3, C-14 and Co-60 in Decommissioning of the Biological Shielding Concrete of KRR-2

SOME ASPECTS OF MONTE CARLO SIMULATION FOR EFFICIENCY CALIBRATION OF GERMANIUM DETECTORS

WM2014 Conference, March 2 6, 2014, Phoenix, Arizona, USA

Quartz-Crystal Spectrometer for the Analysis of Plutonium K X-Rays

ISO INTERNATIONAL STANDARD

Uncertainty Quantification for Safeguards Measurements

Pt L X-RAYS PRODUCTION CROSS SECTIONS BY 12 C, 16 O, 32 S AND 48 Ti ION-BEAMS IN THE MeV/u ENERGY RANGE *

Comparison of the Photo-peak Efficiencies between the Experimental Data of 137 Cs Radioactive Source with Monte Carlo (MC) Simulation Data

TECHNICAL WORKING GROUP ITWG GUIDELINE ON LABORATORY APPLICATIONS OF HIGH-RESOLUTION GAMMA SPECTROMETRY

DETERMINATION OF CORRECTION FACTORS RELATED TO THE MANGANESE SULPHATE BATH TECHNIQUE

Enriched Uranium Waste Assay at AWE

Indian J.Sci.Res.2(3) :25-32, 2011

Digital simulation of neutron and gamma measurement devices

VALIDATION OF IQ3 MEASUREMENTS FOR HIGH-DENSITY LOW-ENRICHED-URANIUM WASTE DRUMS AT PELINDABA

SELF-ATTENUATION FACTORS IN GAMMA-RAY SPECTROMETRY M. KORUN * )

A Monte Carlo Simulation for Estimating of the Flux in a Novel Neutron Activation System using 252 Cf Source

SYSTEM OF MONITORING THE ATMOSPHERICAL RADON WITH AN IONIZATION CHAMBER DETECTOR TYPE IN PULSE MODE

Determination of the activity of radionuclides

1. INTRODUCTION 2. EXPERIMENTAL SET-UP CHARACTERIZATION OF A TUBULAR PLASMA REACTOR WITH EXTERNAL ANNULAR ELECTRODES

The IAEA-CU world wide open proficiency test on the determination of radionuclides in soil, spinach and water

Developing DRF for 1 X1 LaBr 3 Detector. Sangkyu Lee

Deuteron activation cross section measurements at the NPI cyclotron

Effect of Co-60 Single Escape Peak on Detection of Cs-137 in Analysis of Radionuclide from Research Reactor. Abstract

Simulation of 4π HPGe Compton-Suppression spectrometer

A NON-DESTRUCTIVE METHOD FOR MEASUREMENT OF MOISTURE IN BUILDING MATERIALS

NEW DETECTION TECHNIQUES FOR GAMMA RADIATIONS AND POSSIBLE APPLICATIONS

Gamma background measurements in the Laboratoire Souterrain de Modane

International Journal of Scientific & Engineering Research, Volume 5, Issue 3, March-2014 ISSN

COUNT RATE EFFECTS ON PEAK SHAPE AND THROUGHPUT IN DIGITAL AND ANALOG GAMMA RAY SPECTROMETRY

The Efficiency Characterization of Germanium Detectors at Energies less than 45 kev

High Purity Germanium Detector Calibration at ISOLDE

A Radiation Monitoring System With Capability of Gamma Imaging and Estimation of Exposure Dose Rate

Inaccuracy Determination in Mathematical Model of Labsocs Efficiency Calibration Program

1 cm. Cu electrode. Ge crystal. end cap. Dead layer. crystal cup

CZT Gamma Spectrometry Applied to the In-situ Characterisation of Radioactive Contaminations

The Best Gamma-Ray Detector

The first model was based only on the CANBERRA information which we. drawing. Canberra refused any other information.

Journal of Radiation Protection and Research

SIMULATION OF LASER INDUCED NUCLEAR REACTIONS

28th Seismic Research Review: Ground-Based Nuclear Explosion Monitoring Technologies DESIGN OF A PHOSWICH WELL DETECTOR FOR RADIOXENON MONITORING

IDENTIFICATION AND QUANTIFICATION OF RADIONUCLIDES IN HISTORICAL WASTE AT ANSTO

Evaluation of Nondestructive Assay Characterization Methods for Pipe- Over-Pack Containers

Geant4 Monte Carlo code application in photon interaction parameter of composite materials and comparison with XCOM and experimental data

Jazan University College of Science Physics Department. Lab Manual. Nuclear Physics (2) 462 Phys. 8 th Level. Academic Year: 1439/1440

Gamma-ray shielding of concretes including magnetite in different rate

Simple Experimental Design for Calculation of Neutron Removal Cross Sections K. Groves 1 1) McMaster University, 1280 Main St. W, Hamilton, Canada.

Detection of 106 Ru, via the decay of its daughter 106 Rh, in gammaray

University of Montenegro Centre for Nuclear Competence and Knowledge Management Podgorica,, Montenegro

Quantitative Assessment of Scattering Contributions in MeV-Industrial X-ray Computed Tomography

Characterization of Large Structures & Components

Single Channel Beta-Gamma Coincidence Detection of Radioactive Xenon Using Digital Pulse Shape Analysis of Phoswich Detector Signals

Au-Ti THIN FILMS DEPOSITED ON GaAs

THE ANNUAL EFFECTIVE DOSE FROM NATURAL RADIONUCLIDES SOIL SURFACES OF UZHGOROD AREA

Gamma background measurements in the Boulby Underground Laboratory

The metrology of radioactivity. C. Michotte, BIPM

Radioactive Waste Management

The Shape of the Full-Energy Gamma Ray Peak in Germanium Detectors for Different Energies and Incident Geometries

RADIOMETRIC METHODS OF MEASURING THE SPECIFIC ACTIVITY OF RADIONUCLIDES OF THE URANIUM SERIES

Compton Camera. Compton Camera

First tests of the big volume ultra low background gamma spectrometer

LANTHANUM BROMIDE SCINTILLATION DETECTOR FOR GAMMA SPECTROMETRY APPLIED IN INTERNAL RADIOACTIVE CONTAMINATION MEASUREMENTS

A TOMOGRAPHIC SEGMENTED GAMMA SCANNER FOR THE MEASUREMENT OF DECOMMISSIONING WASTES

2. A proton is traveling with velocity v, to the right, through a magnetic field pointing into the page as indicated in the figure below.

Frazier L. Bronson CHP Canberra Industries, Inc., Meriden, CT USA ABSTRACT

Computational study to enhance threat detection of radiation portal monitors:

Measurement of Shielding Effectiveness of Building Blocks against 662 KeV Photons

PHYS 3650L - Modern Physics Laboratory

PhD Qualifying Exam Nuclear Engineering Program. Part 1 Core Courses

Coincidence summing. A. E. Richardson and W. W. Sallee

WM 07 Conference, February 25 March 01, 2007, Tucson, AZ

Dependence Of Gamma Ray Attenuation On Concentration Of Manganese (II) Chloride Solution

Transcription:

NUCLEAR PHYSICS EFFICIENCY CALIBRATION STUDIES FOR GAMMA SPECTROMETRIC SYSTEMS: THE INFLUENCE OF DIFFERENT PARAMETERS MAGDALENA TOMA 1, OCTAVIAN SIMA 2, CARMEN CRISTACHE 1, FELICIA DRAGOLICI 1, LAURENÞIU DONE 1 1 Horia Hulubei National Institute of Physics and Nuclear Engineering, 407 Atomistilor, Magurele-Bucharest, 077126, Romania, E-mail: magdalenatoma@nipne.ro 2 Physics Department, Bucharest University, 405 Atomistilor, Magurele-Bucharest P.O. Box MG-6, 077125, Romania, E-mail: octaviansima@yahoo.com Received September 26, 2007 The radioactive waste containers, containing different radioactive materials, have to be characterized before their final disposal. Destructive methods, although being the most precise, are also the most expensive and not the easiest ones from the radioprotection point of view. In this situation, high resolution gamma spectrometry proved to be a reliable method for the non destructive assay method. However, the non-homogenous composition of the radioactive waste inside the drum makes the quantitative characterization of the radioactive waste drum a difficult task. The efficiency calibration procedure is difficult and dependent on different parameters such as: experimental set-up, the sources distribution inside the drum, and also on the nuclear data used for the calculations. The experimental studies complemented with the performed Monte Carlo calculations are presented in this paper. Key words: gamma spectrometry, efficiency calibration, radioactive waste. 1. INTRODUCTION Nuclear waste assay is an integral element of programs such as safeguards, waste management, and waste disposal. The radioactive waste containers, containing different radioactive materials, have to be characterized before their final disposal. The majority of nuclear waste is packaged in drums and analyzed by various techniques to identify and quantify the radioactive content. Due to various regulations and the public interest in nuclear issues, the analytical results are required to be of high quality. Destructive methods, although being the most precise, are also the most expensive and not the easiest ones from the radioprotection point of view. In this Paper presented at the 8th International Balkan Workshop on Applied Physics, 5 7 July, 2007, Constanþa, Romania. Rom. Journ. Phys., Vol. 53, Nos. 7 8, P. 795 800, Bucharest, 2008

796 Magdalena Toma et al. 2 situation, high resolution gamma spectrometry proved to be a reliable method for the non destructive assay method. However, the non-homogenous composition of the radioactive waste inside the drum makes the quantitative characterization of the radioactive waste drum a difficult task. The calibration procedure is difficult [1] and dependent on different parameters such as: experimental set-up, the sources distribution inside the drum [2 5], and also on the nuclear data used for the calculations. The experimental studies and test cases with Monte Carlo calculations performed are presented in this paper. In our country, the radioactive waste is generally packed in type A containers (220 l drums). For the intermediate and final disposal of medium and low activity radioactive waste, the Romanian law authorizes this kind of packing. 2. EXPERIMENTAL SET-UP For the experimental determinations, a calibration drum (similar with the one used in normal conditioning of the waste) and a linear reference source were used. The drum is provided with 7 hollow parallel tubes of 20 mm diameter, the rest of the drum is filled with Portland cement similar with the one used for the drums. The tubes are placed in the calibration drum at different radial distances from the drum centerline as follows: 7 (center), 6 (7 cm), 5 (12 cm), 4 (16 cm), 3 (19 cm), 2 (21.5 cm), 1 (24.5 cm) from center, respectively. The drum has 82 cm length (Fig. 1). Fig. 1 A schematic representation of the measurement geometry for the calibration drum. The linear reference source is composed of six 152 Eu liquid sources of equal activity, each introduced in a glass ampoule with length l = 55 mm (Fig. 2). The ampoules were placed at equal distances in a plastic tube. The length of the linear source is 620 mm equal with the length of the active volume of the drum. In the normal conditioning of the waste both ends of the drum are

3 Efficiency calibration for gamma spectrometric systems 797 Fig. 2 152 Eu reference source. filled with 10 cm of cement. In order to be in concordance with the active length of the drum, the source has 10 cm of its length inactive at both ends. For the efficiency calculation the linear reference source is introduced in the hollow tubes from the calibration drum. During the efficiency calibration only one tube at a time was filled with the linear reference source leaving the others empty. The waste assay system [5] has a lead-collimated vertical HPGe detector, of 30% relative efficiency and 1.8 kev energy resolution (at 1332 kev). The rectangular collimator window has the length 10 cm and the width 4 cm. The lead shield has the interior diameter 9 cm and the wall thickness 4.4 cm. The detector was located at 32.5 cm in radial direction from the surface of the calibration drum In order to minimize the effect of non-homogeneous matrix and sources distribution in typical measurements of waste drums, the drum is rotated and translated (a double translation) in front of an HPGe collimated detector, while the measurement is performed 3. RESULTS AND DISCUSSIONS 3.1. EXPERIMENTAL The efficiency calibration for a uniformly distributed radioactive waste was performed using the shell-sources method [6 10]. This method provides the efficiency values for the case when only a part of the drum, namely a cylinder of radius x, coaxial with the drum, contains radioactive sources, the rest of the drum being filled with inactive concrete. In Table 1 the corresponding efficiencies are presented for several values of x. It can be observed that for a source distributed in the entire volume of the drum (x = 28.5 cm), the calibration curve has a pattern approximately similar to a normal one.

798 Magdalena Toma et al. 4 E Table 1 The detection efficiency for several values of x (cm) Efficiency [kev] 28.5 24.5 21.5 19.5 16.5 12.5 122 1.250 10 6 5.540 10 7 2.190 10 7 9.930 10 8 2.530 10 8 3.570 10 9 344 1.470 10 6 7.760 10 7 4.020 10 7 2.370 10 7 9.920 10 8 3.230 10 9 779 1.330 10 6 8.010 10 7 4.960 10 7 3.430 10 7 1.860 10 7 7.730 10 8 964 1.350 10 6 8.270 10 7 5.250 10 7 3.710 10 7 2.090 10 7 9.070 10 8 1112 1.350 10 6 8.500 10 7 5.580 10 7 4.060 10 7 2.380 10 7 1.080 10 7 1408 1.420 10 6 9.180 10 7 6.190 10 7 4.590 10 7 2.780 10 7 1.310 10 7 For a source distributed in smaller volumes (cylinders of the same length as the drum, but with the radius x smaller than the radius R of the drum, the rest of the drum being filled with inactive concrete), generally, the attenuation of gamma rays of low energy in cement layer is much stronger than that of the high-energy gammas. As a result, the efficiency curve presents a slowly increasing pattern with energy, though the relative efficiency of the detector decreases with gamma ray energy. 3.2. MONTE CARLO CALCULATION In this work, also, the Monte Carlo based GESPECOR software was applied for the computation of the efficiency. The principles of the program and the extension for the measurement of high volume samples have been published elsewhere [7 9]. The efficiency values for different matrix densities (ρ = 1.6, 1.8, 2.0, 2.2, 2.3 and 2.4 g/cm 3 ) for two situations of interest were computed: in the cases of a point source placed at the half-distance between the drum s ends. As the point source, one of the six liquid 152 Eu sources, from the linear reference source, was used and the linear source with the drum only rotated. The relative variation of these efficiencies with energy for r = 0 cm and r = 24.5 cm, for both linear source and point source are presented in Fig. 3. As it can be observed, the effect of density variations is small for shell sources placed far from the center of the drum and increases as the shell source is displaced toward the center. Without proper knowledge of the source distribution it is impossible to apply accurate density corrections to the efficiency. Monte-Carlo calculations can cover situations which experimentally can not be realized such as efficiency calibration for different matrix density, for different positions of a radioactive source inside the drum (experimental only for

5 Efficiency calibration for gamma spectrometric systems 799 Fig. 3 The relative variation of the computed efficiencies with energy for density variations. The point source (PS) and linear source (LS) are placed in two positions (r = 24.5 cm, r = 0 cm) inside the drum, the drum being only rotated. the concrete density could be archived, as could be observed). In this situation, in order to be able to investigate the effect of the density variations of the efficiency a simulation technique is required. But other features of the experimental set-up are also important. For example, a change by 1 cm of the length of the collimator along the accepted photon paths results in a gradual change of the efficiency by approx. 20% for the linear source in position 7 to 4% for the linear source in position 1. The work is in progress. REFERENCES 1. Klaus Debertin, Richard G. Helmer, Gamma and X-ray spectrometry with semiconductor detectors, Elsevier Science Publishers B. V. (1988). 2. M. Bruggerman, J. Gerits, R. Carchon, A minimum biased shell-source method for the calibration of rad waste assay system, Applied Radiation and Isotopes 51, 255 259, 1999.

800 Magdalena Toma et al. 6 3. J. H. Liang, S. H. Jiang, G. T. Chou, A Theoretical Investigation of Calibration for Radwaste Radioactivity Detection System, Applied Radiation and Isotopes vol. 47. No. 7, 669 675, 1996. 4. J. H. Liang, S. H. Jiang, J. T. Chou, C. C. Chen, S. W. Lin, C. H. Lee, S. T. Chiou, Parametric Study of Shell-source Method for Calibrating Radwaste Radioactivity Detection Systems, Applied Radiation and Isotopes vol. 49, No. 4, 361 368, 1998. 5. M. Bruggerman, R. Carchon, Solidang a computer code for the computation of the effective solid angle and correction factors for gamma spectroscopy-based waste assay, Applied Radiation and Isotopes 52, 771 776, 2000. 6. P. Filb, Relation between the activity of a High Density Waste Drum and its Gamma Count Rate Measured with an Unshielded Ge-detector, Applied Radiation and Isotopes vol. 46, No. 8, 805 812, 1995. 7. L. Dinescu, I. Vata, I. L. Cazan, R. Macrin, Gh. Caraghergheopol, Gh. Rotarescu, On the efficiency calibration of a drum waste assay system, Nuclear Instruments and Methods in Physics Research A 487, 661 666, 2002. 8. O. Sima, C. Dovlete, Matrix Effects in the Activity Measurement of Environmental Samples Implementation of Specific Corrections in a Gamma-ray Spectrometry Analysis Program, Applied Radiation and Isotopes 48, 59 69, 1997. 9. O. Sima, D. Arnold, C. Dovlete, GESPECOR: a versatile tool in gamma ray spectrometry, J. Radioanal. Nucl. Chem. 248 (2), (2001), 359 364. 10. M. Haralambie, L. Dinescu, O. Sima, New data concerning the efficiency calibration of a drum waste assay system. Part I: Experimental calibration. Romanian Reports in Physics, Vol. 56, No. 4, (2004) p. 711 720.