Z7A. Load cells. Special features. Data sheet. Wiring code

Similar documents
Single point load cells

Load cell. Special features. Data sheet

Level Sensor PanCake PR 6251 and Mounting Kit PR 6051

T20WN. Data Sheet. Torque transducers. Special features. Installation example with bellows couplings. B en

Ring-Torsion Load Cells RTB

TOP Transfer. Data Sheet. Force transfer standard. Special characteristics. D 20.TOPTRANS.10 en

TOP Transfer. Data sheet. Force transfer standard. Special features. B en

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Type UB1 Load Cell. Option Stainless steel cable gland

4.2. Ex-Ceiling light fittings AB 80 / AB 05 LED / AB 05 / AB 12 NAV 70. (Zone 1, 2, 21, 22)

TB2. Data Sheet. Torque reference transducer. Special features. B en

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

Load Cells. 3/2 Introduction. 3/3 Mounting components 3/3 Introduction

Pressure transmitters for industrial applications MBS 32 and MBS 33

4.13. Ex-Floodlights of the series FMV LED / NSSFMV. (Zone 2, 22) service life and a high level of efficiency. NFMV floodlights for highpressure

Ex-Floodlights of the series FMV LED / NFMV / NSSFMV. Stainless steel NSSFMV floodlights for particularly. in harsh environments

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

Benefits/Application. Very high-cycle fatigue resistant up to 100 % of nominal load. Extremely robust against side forces and bending moments

ED 701 General Industry Pressure Transmitter

TF 202 / TF 202-Ex. Field mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27

BSD MODULFLEX R Torsionally Rigid Couplings

4.3. Ex-Pendant light fittings AB 50 / SPG 1N / AB 51 / EVI 200 / EVI 500 / EV35 LED. (Zone 1, 2, 21, 22)

Benefits/Application. Very high-cycle fatigue resistant up to 80 % of nominal load. Easy assembling, lots of possibilities. Options/Accessories

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.

Benefits/Application. For static and dynamic tensile and compressive forces. Easy assembling, lots of possibilities. Options/Accessories

TF 212 / TF 212-Ex. Field mounted temperature transmitters, PROFIBUS PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels 10/11-8.

Explosion-protected recessed ceiling LED-light and fluorescent light fittings

ATEX/IECEx RTD temperature probe

Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22)

EX-EMERGENCY LIGHT FITTINGS

D a t a s h e e t. F o r c e T r a n s d u c e r. S e r i e s K. ( 4 k N k N ) Benefits/Application. Options/Accessories

DS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

I Ex d/e Switch- and Control-Equipment I

Pressure Measurement Single-range transmitters for general applications

S95.3U01 / S95.3U11. Head mounted temperature transmitters, programmable, Pt 100 (RTD), thermocouples, electrical isolation

ZF Series Force Transducers

2.12. Ex-Linear light fittings for fluorescent lamps. nllk W - 58 W (Zone 2, 21, 22)

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

SINEAX VK 636 Programmable Temperature Transmitter with PROFIBUS-PA protocol

PHOENIX CONTACT - 04/2016. Features

2.12. Ex-Linear light fittings for fluorescent lamps - max. ambient temperature + 60 C - nllk W - 58 W for Zone 2 and 22

HYGRASGARD KFF KFTF HYGRASGARD AFF AFTF HYGRASGARD AFF - LC AFTF - LC

Field mounted Temperature Transmitter TF212/TF212-Ex

ANNEX to IECEx Certificate

I nllk 08018/18 I nllk I nllk 08036/36 I nllk I I nllk 08058/58 I

Exchangeable measuring insets SensyTemp TSA101

DS 200 DS 200 DRUCK & TEMPERATUR LEITENBERGER GMBH. Electronic Pressure Switch. Stainless Steel Sensor. Electronic Pressure Switch

Installation guide 862 MIT / MIR

D a t a s h e e t. T o r q u e s t a n d a r d. S e r i e s D m - T N. ( 1 N m N m ) Benefits/Application. Options/Accessories

Field IT 50T Series Transmitters

SINEAX VK 626 Programmable Temperature Transmitter for RTD and TC inputs, with HART protocol

1551A Ex/1552A Ex Intrinsically Safe Stik Thermometer. The new gold standard of industrial temperature calibration

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas

E8EB-N0C2B E8EB-N0B2B

S95.3U02 / S95.3U12. Head mounted temperature transmitters, HART programmable, Pt 100 (RTD), thermocouples, electrical isolation

TF 212 / TF 212-Ex. Field mounted temperature transmitter, Profibus PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels. ABB Instrumentation

A BB ME ASU R E ME NT & AN AL Y T ICS D AT A S H E ET. SensyTemp TSA101 Exchangeable measuring insets

Installation Equipment

Ex floating switches and Ex immersion probes

Universal limit switches

Dimensional drawing face mount flange radial. R = bending radius min. 40 mm. Dimensional drawing face mount flange axial

ISEmax CAM40/CAS40. Technical Information

Single Phase Motors Technical Datasheets

Strain Gauges and Accessories

PRODUCT CATALOGUE PREssURE switch

E X - C O N T R O L U N I T S A N D C O N T R O L S T A T I O N S

D5.2 Type. Draw wire mechanics with incremental encoder. Measuring length max. 2 m. Compact and simple. Order code draw wire encoder

TH 202 / TH 202-Ex. Field mounted temperature transmitter, HART programmable, Pt 100 (RTD), thermocouples, electrical isolation. ABB Instrumentation

Pressure Transmitter ED 701

Designed to go where you work

Linear measuring technology

DRS 61: Incremental encoders, number of lines and zero pulse width freely programmable DRS 60: Incremental Encoders with Zero-Pulse-Teach

INVESTIGATION OF THE CALIBRATION CAPABILITIES OF A 1 KN M AND 10 KN M REFERENCE CALIBRATION MACHINE

T e c h n i c a l L e x i c o n

Absolute encoders multiturn

Industrial Pressure Transmitter

Industrial Pressure Transmitter

DBS315 1-phase SIDE CHANNEL BLOWERS

4/4-way servo solenoid directional control valves, directly operated, with electrical position feedback and on-board electronics (OBE)

Thermal-Magnetic Circuit Breaker 2210-T2...

Overload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011

Switches in conformity with ATEX directive

Non-Contact Safety Systems CMS

VK2 volume flow controller Overview

5SJ4...-.HG Circuit Breakers to IEC and UL 489

Surface-mounting thermostats Series ATH

Increased Requirements for Higher Nominal Forces, Necessities and Possibilities to Measure Them

Operating Instructions for Digital Manometer. Model: MAN-SD

A compression load cell, with strain gauges, tested as a part of a weighing instrument. Manufacturer : Molen or Precia Molen.

Fitting PS P - B - R2

Wind Speed & Direction Sensors

RoHS. Versatile. X g. X 2 e


CALYS 80P. Field pressure calibrator with high accuracy 0.01%

Capacitance Level Measurement Electronic Inserts EC 37 Z, EC 47 Z

Load Washers. Force. for Forces of 7, kn. F z. Type 9001A A 9081B, 9091B

HR-Z SERIES Mild Radiation Resistance LVDT

Transcription:

Z7A Load cells Special features - Complies with OIML R60 regulations up to 3000 d - Max. capacities: 500 kg... 10 t - Fulfills EMC requirements in accordance to EN 45 501 - Low transducer height - Robust design Data sheet Wiring code 6 wire circuit (gray) (black) Sense (-) Excitation (-) (white) Signal (+) (blue) (green) Excitation (+) Sense (+) (red) Signal (-) (-) Shield / wire strand connected with housing

Dimensions Z7A (in mm, 1mm = 0.03937inches) øl Cable: 6 cores, screened 5.4-6 m long H K2 N øm A D F G E K1 C B J Nominal load in t L +0.2 M H11 J B H N A D F G E C K1 K2 M* in N m 0.5 and 1 30.2 17.5 13.4 47.6 11.1 11.9 203.2 101 98.3 63.5 19.1 36.5 10.6 29 135 2 30.2 17.5 13.4 47.6 11.1 11.9 203.2 102 98.3 63.5 19.1 36.5 10.6 29 135 5 41.3 25.5 22.5 70 22.2 15.9 235 118 123.7 66.5 20.6 47.6 16 46 660 10 51 32 27 82.6 19.1 20.7 279.4 140 139.7 82.6 25.4 60.3 21 51 1150 * Tightening torque with screws of property class 10.9 (with μ=0.16). Accessories, to be ordered sparately: rubber metal bearing ZEL Pendulum bearing ZPL HBM 2

Specifications Type Accuracy class according to OIML R 60 Max. number of load cell verification intervals (n LC ) D1 1 000 Z7A C3 3 000 Max. capacity (E max ) t 0.5; 1; 2; 5; 10 2; 5; 10 Min. load cell verification interval (v min ) % of E max 0.0357 0.0100 Sensitivity (C n ) mv/v 2 Sensitivity tolerance % 0.1000 0.0500 Temperature effect on sensitivity (TK C ) 1) 0.0350 0.0117 % of C n /10 K Temperature effect on zero signal (TK 0 ) 0.0500 0.0140 Hysteresis error (d hy ) 1) Non linearity (d lin ) 1) Creep (d cr ) in 30 min. % of C n 0.0500 0.1000 0.0735 0.0170 0.0333 0.0167 Input resistance (R LC ) at reference temperature 350 Ω Output resistance (R O ) at reference temperature 356 0.2 356 0.12 Nominal rang of excitation voltage (U ref ) Maximum excitation voltage (B U ) Reference temperature Nominal temperature range (B T ) Operating temperature range (B tu ) Storage temperature range (B tl ) Save load limit (E L ) Breaking load (E d ) V 0.5...12 18 +23 [+73.4] -10...+40 [+14...+104] C [ F] -30...+70 [-22...+158] -50...+85 [-58...+185] 150 % of E max 300 Max. capacity (E max ) t 0.5 1 2 5 10 Relative static lateral force limit (E lq ) 2) 100 50 25 15 18 (100) 2) (100) 2) (100) 2) Permissible dynamic load (F srel ) (vibration amplitude according to DIN 50100) % of E max 70 Nominal displacement (s nom ), approx. Weight (G), approx. Degree of protection according to EN60529 (IEC529) IP 67 Material Measuring body Cable gland Cable sheath mm kg 0.25 2.3 0.30 2.3 0.35 2.3 0.45 5 Steel, galvanized Stainless steel / Viton PVC 1) The values stated for the non linearity, the hysteresis and the temperature coefficient of sensitivity are standard values. The sum of these values is within the accumulated error limit according to OIML R60. 2) The values given in parentheses refer to installation with stops preventing the transducer base from moving. In this case, major error effects have to be anticipated. 0.70 8 Options Ex protection versions as per IECEx and ATEX AI1/21 IECEx+ATEX zone 1/21 + FM intrinsically safe, II 2G Ex ia IIC T6/T4 Gb, II 2D Ex ia IIIC T125 C Db* AI2/22 IECEx+ATEX Zone 2/22 non-intrinsically safe, II 3G Ex na IIC T6/T4 Gc, II 3D Ex tc IIIC T125 C Dc* * with EU type examination certificate (BVS13ATEX E 108 X) and IECEx Certificate of Conformity (IECEx BVS 13.0109 X) 3 HBM

Mounting aids ( Dimensions in mm; 1mm = 0.03937 inches ) Rubber metal bearing ZEL R Z X e B ZEL a Y T L P Max. capacity in t Rubber metal bearing ZEL B L P R T X Y Z a e F R * (N) 0.5...2 Z17/2t/ZEL 76.3 180.9 70 100 9 120 60 10 112 +1,5 1,7 5 Z17/5t/ZEL 93 210.8 70 125 11 150 100 10 147 +1,2 2,0 10 HLCB/10t/ZEL 114.1 247.7 90 175 13 200 100 12 176 +1,8 2,0 s max ** (mm) 80 400 4.5 100 620 8 130 810 9.5 * F R =restoring force for s=1mm. ** s max =max. lateral displacement of load introduction with max. capacity. Pendulum bearing ZPL F 1 T jc 1 M E ju jo D 1 ZPL maximum inclination of 3 H 2 dust proof protection rings and a fixing screw included with ZPL jc Max. capacity in t Pendulum bearing ZPL C +0.2 C 1-0.1 D 1 E F 1 H M O T U D10 h9 F R * (% of load) 0.5...2 Z17/2t/ZPL 30.2 30 60 22 14 130 0.5 M10 46 8 30 2 7.5 5 Z17/5t/ZPL 41.3 41.1 73 26 16 169 0.5 M10 48 8 30 1.5 6.9 10 Z17/10t/ZPL 51 50.8 82 32 21 196 0.5 M12 58 10 40 1.8 9.3 * F R =restoring force for s=1mm. ** s max =max. lateral displacement of load introduction with nominal load. s max ** (mm) HBM 4

Z7A load cells, optional versions Order number K Z7A Code S Option 1: Mechanical design Standard Code Option 2: Accuracy class D1 D1 (OIML) C3 C3 (OIML) [only with Option 3 = 2 / 5 / 10] Code Option 3: Nennlast 500 500 kg [only with Option 2 = D1] 1 1 t [only with Option 2 = D1] 2 2 t 5 5 t 10 10 t Code Option 4: Explosion protection N No expolsion protection AI1/21 IECEx + ATEX zone 1/21 and FM AI2/22 IECEx + ATEX zone 2/22 Code Option 5: Cable length S 6 m (standard) 12 12 m Code N Option 6: Other Standard K-Z/A - S - - - - - N 5 HBM

Subject to modifications. All product descriptions are for general information only. They are not to be understood as a guarantee of quality or durability. measure HBM and predict with confidence 6 Hottinger Baldwin Messtechnik GmbH Im Tiefen See 45 64293 Darmstadt Germany Tel. +49 6151 803 0 Fax +49 6151 803 9100 Email: info@hbm.com www.hbm.com