Process Control J.P. CORRIOU. Reaction and Process Engineering Laboratory University of Lorraine-CNRS, Nancy (France) Zhejiang University 2016

Similar documents
Chapter 2 Linear Feedback Control

Chapter 8. Feedback Controllers. Figure 8.1 Schematic diagram for a stirred-tank blending system.

Process Control & Design

Analysis and Design of Control Systems in the Time Domain

CHBE320 LECTURE XI CONTROLLER DESIGN AND PID CONTOLLER TUNING. Professor Dae Ryook Yang

Feedback Control of Linear SISO systems. Process Dynamics and Control

Dr Ian R. Manchester

Goodwin, Graebe, Salgado, Prentice Hall Chapter 11. Chapter 11. Dealing with Constraints

SIMULATION SUITE CHEMCAD SOFTWARE PROCESS CONTROL SYSTEMS PROCESS CONTROL SYSTEMS COURSE WITH CHEMCAD MODELS. Application > Design > Adjustment

Proportional, Integral & Derivative Control Design. Raktim Bhattacharya

BASIC PROPERTIES OF FEEDBACK

Subject: BT6008 Process Measurement and Control. The General Control System

: INSTRUMENTATION AND PROCESS CONTROL COURSE CODE : 6071 COURSE CATEGORY : A PERIODS/ WEEK : 5 PERIODS/ SEMESTER : 75 CREDIT : 5 TIME SCHEDULE

Lecture 12. Upcoming labs: Final Exam on 12/21/2015 (Monday)10:30-12:30

Part IB Paper 6: Information Engineering LINEAR SYSTEMS AND CONTROL. Glenn Vinnicombe HANDOUT 5. An Introduction to Feedback Control Systems

Systems Analysis and Control

Introduction to Feedback Control

Automatic Control 2. Loop shaping. Prof. Alberto Bemporad. University of Trento. Academic year

Class 27: Block Diagrams

Control of Manufacturing Processes

Lecture 12. AO Control Theory

Dr Ian R. Manchester Dr Ian R. Manchester AMME 3500 : Review

Lecture 25: Tue Nov 27, 2018

1 Loop Control. 1.1 Open-loop. ISS0065 Control Instrumentation

(Refer Slide Time: 1:42)

PID controllers, part I

6.1 Sketch the z-domain root locus and find the critical gain for the following systems K., the closed-loop characteristic equation is K + z 0.

Acceleration Feedback

Step input, ramp input, parabolic input and impulse input signals. 2. What is the initial slope of a step response of a first order system?

CM 3310 Process Control, Spring Lecture 21

A Tuning of the Nonlinear PI Controller and Its Experimental Application

Control Lab. Thermal Plant. Chriss Grimholt

EE3CL4: Introduction to Linear Control Systems

Radar Dish. Armature controlled dc motor. Inside. θ r input. Outside. θ D output. θ m. Gearbox. Control Transmitter. Control. θ D.

Feedback Basics. David M. Auslander Mechanical Engineering University of California at Berkeley. copyright 1998, D.M. Auslander

Robotics Intelligent sensors (part 2)

CPC Engineering Training Brochure

Theory and Design for Mechanical Measurements

Exercise 8: Level Control and PID Tuning. CHEM-E7140 Process Automation

APPLICATIONS FOR ROBOTICS

Sinusoidal Forcing of a First-Order Process. / τ

( ) Frequency Response Analysis. Sinusoidal Forcing of a First-Order Process. Chapter 13. ( ) sin ω () (

CHAPTER 3 TUNING METHODS OF CONTROLLER

Root Locus. Motivation Sketching Root Locus Examples. School of Mechanical Engineering Purdue University. ME375 Root Locus - 1

CHAPTER 13: FEEDBACK PERFORMANCE

Open Loop Tuning Rules

Digital Control: Summary # 7

Raktim Bhattacharya. . AERO 422: Active Controls for Aerospace Vehicles. Basic Feedback Analysis & Design

AN INTRODUCTION TO THE CONTROL THEORY

Tuning of Internal Model Control Proportional Integral Derivative Controller for Optimized Control

MAS107 Control Theory Exam Solutions 2008

= A x (t) + B utt), by d{ _-=-=-

ECE 388 Automatic Control

Dynamic modelling J.P. CORRIOU. Reaction and Process Engineering Laboratory University of Lorraine-CNRS, Nancy (France) Zhejiang University 2016

Laboratory Exercise 1 DC servo

School of Mechanical Engineering Purdue University. ME375 Feedback Control - 1

Controls Problems for Qualifying Exam - Spring 2014

EXAMINATION INFORMATION PAGE Written examination

NonlinearControlofpHSystemforChangeOverTitrationCurve

ME 304 CONTROL SYSTEMS Spring 2016 MIDTERM EXAMINATION II

sc Control Systems Design Q.1, Sem.1, Ac. Yr. 2010/11

Alireza Mousavi Brunel University

Aircraft Stability & Control


Appendix A MoReRT Controllers Design Demo Software

Professional Portfolio Selection Techniques: From Markowitz to Innovative Engineering

LABORATORY INSTRUCTION MANUAL CONTROL SYSTEM I LAB EE 593

Closed Loop Identification Of A First Order Plus Dead Time Process Model Under PI Control

Lecture 5 Classical Control Overview III. Dr. Radhakant Padhi Asst. Professor Dept. of Aerospace Engineering Indian Institute of Science - Bangalore

Control for. Maarten Steinbuch Dept. Mechanical Engineering Control Systems Technology Group TU/e

06 Feedback Control System Characteristics The role of error signals to characterize feedback control system performance.

Prüfung Regelungstechnik I (Control Systems I) Übersetzungshilfe / Translation aid (English) To be returned at the end of the exam!

DC-motor PID control

Control Of Heat Exchanger Using Internal Model Controller

IMC based automatic tuning method for PID controllers in a Smith predictor configuration

Solutions for Tutorial 10 Stability Analysis

D(s) G(s) A control system design definition

Chapter 2. Classical Control System Design. Dutch Institute of Systems and Control

Roll No. :... Invigilator s Signature :.. CS/B.Tech (EIE)/SEM-5/EI-501/ INDUSTRIAL INSTRUMENTATION II

Control System Design

Internal Model Control of A Class of Continuous Linear Underactuated Systems

2.830J / 6.780J / ESD.63J Control of Manufacturing Processes (SMA 6303)

Acknowledgements. Control System. Tracking. CS122A: Embedded System Design 4/24/2007. A Simple Introduction to Embedded Control Systems (PID Control)

10 Measurement of Acceleration, Vibration and Shock Transducers

Enhanced Single-Loop Control Strategies Chapter 16

A FEEDBACK STRUCTURE WITH HIGHER ORDER DERIVATIVES IN REGULATOR. Ryszard Gessing

AMJAD HASOON Process Control Lec4.

Tuning PI controllers in non-linear uncertain closed-loop systems with interval analysis

Control Engineering BDA30703

Index. Index. More information. in this web service Cambridge University Press

TS02 - Pre-Instructional Survey

Task 1 (24%): PID-control, the SIMC method

CHEMICAL ENGINEERING

Pole placement control: state space and polynomial approaches Lecture 2

FEEDBACK CONTROL SYSTEMS

Introduction. Measurement of temperature is generally considered to be one of the simplest and most accurate measurements performed in engineering.

Control Systems Design

Control System. Contents

Experimental Study of Fractional Order Proportional Integral (FOPI) Controller for Water Level Control

Transduction Based on Changes in the Energy Stored in an Electrical Field

Transcription:

Process Control J.P. CORRIOU Reaction and Process Engineering Laboratory University of Lorraine-CNRS, Nancy (France) Zhejiang University 206 J.P. Corriou (LRGP) Process Control Zhejiang University 206 / 37

Linear Feedback Control Most popular control method in industry is proportional-integral-derivative or PID controller, around 95% of industrial problems. Apparent simplicity of understanding and generally satisfactory performance. Based on action on the process according to the error between the set point and the measured output. Numerous variants of PID exist. Improvements possible by better tuning. J.P. Corriou (LRGP) Process Control Zhejiang University 206 2 / 37

Design of a Feedback Loop Process representation in open loop d(t) u(t) Process y(t) Open loop can work only if the process model is perfect and in the absence of disturbances, noise. J.P. Corriou (LRGP) Process Control Zhejiang University 206 3 / 37

Design of a Feedback Loop Process representation in closed loop Disturbance d(t) Controller Set point e(t) u a (t) u(t) Output Corrector Actuator Process y r (t) + y(t) y m (t) Measurement Objective : maintain the output y as close as possible to the desired set point y r for any disturbance. J.P. Corriou (LRGP) Process Control Zhejiang University 206 4 / 37

Design of a Feedback Loop The output is measured using a given measurement device ; the value indicated by the sensor is y m. This value is compared to the set point y r, giving the difference [set point measurement] to produce the error e = y r y m. The value of this error e is provided to the main corrector to modify the control variable u. J.P. Corriou (LRGP) Process Control Zhejiang University 206 5 / 37

General Types of Controllers A controller represents a control strategy, i.e. a set of rules providing a value of the control action when the output deviates from the set point. A controller can thus be constituted by an equation or an algorithm. In this first stage, only simple conventional controllers are considered. J.P. Corriou (LRGP) Process Control Zhejiang University 206 6 / 37

Proportional (P) Controller Operating output of the proportional controller is proportional to the error u a(t) = K c e(t)+u ab () where K c is the proportional gain of the controller. u ab is the bias signal of the actuator (u ab = operating signal when e(t) = 0). The gain K c can be positive or negative. The gain K c has dimensions. The higher the gain, the more sensitive the controller. A controller can saturate when its output u a(t) reaches a maximum u a,max or minimum u a,min value. Controller transfer function G c(s) = K c (2) simply equal to the controller gain. Philosophy : the integral action takes into account the present. J.P. Corriou (LRGP) Process Control Zhejiang University 206 7 / 37

Proportional-Integral (PI) Controller The operating output of the PI controller is proportional to the weighted sum of the magnitude and of the integral of the error u a (t) = K c ( e(t)+ τ I t τ I in the integral time constant. 0 ) e(x) dx + u ab (3) The integral action tends to modify the controller output u a (t) as long as an error exists in the process output. Transfer function of the PI controller is equal to ( G c (s) = K c + ) τ I s Philosophy : the integral action takes into account (integrates) the past. J.P. Corriou (LRGP) Process Control Zhejiang University 206 8 / 37 (4)

Ideal Proportional-Derivative (PD) Controller The operating output of the ideal PD controller is proportional to the weighted sum of the magnitude and the time rate of change of the error ( ) de(t) u a (t) = K c e(t)+τ D + u ab (5) dt The derivative action is intended to anticipate future errors. τ D is the derivative time constant. Transfer function of the ideal PD controller G c (s) = K c (+τ D s) (6) Theoretical controller because the numerator degree of the controller transfer function G c (s) is larger than the denominator degree ; consequently, it is physically unrealizable. Philosophy : the derivative action takes into account (anticipates) the future. J.P. Corriou (LRGP) Process Control Zhejiang University 206 9 / 37

Ideal Proportional-Integral-Derivative (PID) Controller Combination of P, I and D actions ( de(t) u a (t) = K c e(t)+τ D + t dt τ I 0 ) e(x) dx + u ab (7) Transfer function of the ideal PID controller ( G c (s) = K c +τ D s + ) τ I s (8) Still derivative action is physical unrealizable. Philosophy : owing to the derivative action, the PID controller takes into account (anticipates) the future, and owing to the integral action, the PID takes into account (integrates) the past. J.P. Corriou (LRGP) Process Control Zhejiang University 206 0 / 37

Comparison of P, PI and PID Controllers P controller : It presents the drawback to create a deviation of the output with respect to the set point. PI controller : It presents the advantage of eliminating the deviation between the output and the set point owing to the integral action. However, this controller can produce oscillatory responses and diminishes the closed-loop system stability. Furthermore, the integral action can become undesirable when there is saturation. PID controller : It can stabilize the output with respect to the PI controller. It is sensitive to the noise. J.P. Corriou (LRGP) Process Control Zhejiang University 206 / 37

Sensors Without good measurement, it is hopeless to control the process well. Common sensors on chemical processes : Temperature sensors : thermocouples, platinum resistance probes, pyrometers. Modelled as first- or second-order model, sometimes with a time delay. Pressure sensors : classical manometers using bellows, Bourdon tube, membrane or electronic ones using strain gauges. Often represented by a second-order model. Flow rate sensors : for gases, thermal mass flow meters, variable area flow meters. For liquids, turbine flow meters, depression flow meters as venturi-type flow meters, vortex flow meters, electromagnetic flow meters, sonic flow meters, Coriolis effect flow meters. Fast dynamics. Often modelled by an equation of the form flow rate = a P J.P. Corriou (LRGP) Process Control Zhejiang University 206 2 / 37

Sensors Level sensors : floats, displacement, conductivity, capacitance. Composition sensors : potentiometers, conductimeters, chromatographs, spectrometers. Sometimes, very long delay (chromatographs). In the absence of a measurement concerning a given variable, if a model of the process is available, it is possible to realize a state observer called a software sensor. Used in particular for composition estimations. In addition of the sensor itself, there is a transmitter, simple converter and simple gain (often transmitted in the range 4-20 ma). J.P. Corriou (LRGP) Process Control Zhejiang University 206 3 / 37

Actuators Actuators constitute material elements allowing action by means of the control loop on the process. 0 0 00 Pneumatic valves. 00 Sliding stem 00 0 00 00 0 00 0 0 0 Design position of a valve : either completely open 0 0 0 0 0 0 000 0 00 0 00 0 0 00 0 0 0 0 0 (fail open, or air-to-open) or completely closed (fail closed, or air-to-close) when the air pressure is not ensured. 0 0 0 00 00 0 00 0 0 0 00 0 0 0 0 0 0 0 0 Many types of valves exist. 0 Valve dynamics is fast. A valve introduces a pressure drop in the pipe. Valves are freequently nonlinear and can saturate. For liquids, flow rate Q depends on the square root of the pressure drop P v of the valve Q = C v P d (9) J.P. Corriou (LRGP) Process Control Zhejiang University 206 4 / 37

Valves FIGURE : Influence of the aperture degree of a valve on its flow rate q = Q Q m 3 4 2 x Linear (case ) : Butterfly (case 4) : Equal percentage (cases 2 and 3) : C v = C vs x C v = C vs ( cos( π 2 x)) C v = C vs R x v (0) J.P. Corriou (LRGP) Process Control Zhejiang University 206 5 / 37

Dynamics of Feedback-Controlled Processes FIGURE : Block scheme of the closed-loop process Process Disturbance D(s) Y r (s) K m Set point Controller Y rm (s) E(s) Corrector Actuator U a (s) U(s) G + c (s) Ga (s) Gp (s) G d (s) + + Y(s) Output Y G m (s) m (s) Measurement Process closed-loop response Y(s) Y(s) = G p(s) G a(s) G c(s) K m +G p(s) G a(s) G c(s) G Yr(s)+ G d (s) D(s) () m(s) +G p(s) G a(s) G c(s) G m(s) J.P. Corriou (LRGP) Process Control Zhejiang University 206 6 / 37

Dynamics of Feedback-Controlled Processes The closed-loop transfer function is equal to product of the transfer functions met on the path between an input and an output +the product of all transfer functions met in the loop sign + is indeed the opposite of the sign of comparison between measured output and set point. Two interesting closed loop transfer functions : between set point and output, influence of set point. between disturbance and output, influence of disturbance. J.P. Corriou (LRGP) Process Control Zhejiang University 206 7 / 37

Dynamics of Feedback-Controlled Processes FIGURE : How the "open loop" must be understood by opposition to the closed loop + G r G a G p G m "Open loop" and "closed loop" must be understood as electrician language. The closed-loop transfer function is equal to product of the transfer functions met on the path between an input and an output + transfer function of the open loop J.P. Corriou (LRGP) Process Control Zhejiang University 206 8 / 37

Dynamics of Feedback-Controlled Processes Closed-loop transfer function for a set point variation G set point = G p (s) G a (s) G c (s) K m +G p (s) G a (s) G c (s) G m (s) (2) Closed-loop transfer function for a disturbance variation G disturbance = G d (s) +G p (s) G a (s) G c (s) G m (s) (3) Same denominators. Closed-loop transfer functions depend not only on the process dynamics, but also on the actuator, measurement device and the controller s own dynamics. J.P. Corriou (LRGP) Process Control Zhejiang University 206 9 / 37

Control problems Separation between two control problems : Regulation (or disturbance rejection) : Fixed set point (Y r (s) = 0 or δy r (t) = 0). Process subjected to disturbances. Tracking : Assumption that disturbance is constant (D(s) = 0 or δd(t) = 0). Set point is variable. J.P. Corriou (LRGP) Process Control Zhejiang University 206 20 / 37

Study of different actions Simplifications : G a =, G m =, K m = (4) Also, assumption that the orders of process transfer function G p and of the disturbance transfer function G d are equal. FIGURE : Block diagram for the study of the action of the different controllers d(t) G d y r (t) + G c u(t) G p y(t) Y(s) = Gp(s) Gc(s) +G p(s) G Yr(s)+ G d (s) D(s) (5) c(s) +G p(s) G c(s) J.P. Corriou (LRGP) Process Control Zhejiang University 206 2 / 37

Proportional Action Case of first-order systems G p(s) = Kp τ p s + ; G d (s) = K d τ d s + (6) Output Y(s) = K p K c τ p s + +K p K c Y r(s)+ K d τ d s + τ p s + τ p s + +K p K c D(s) (7) Final-value theorem : t s 0 gives closed-loop steady-state gain for the set point closed-loop steady-state gain for the disturbance K p and K d 0 if Kc increases. K p K d = Response faster in closed loop than in open loop τ p = = Kp Kc +K p K c (8) K d +K p K c (9) τ p +K p K c (20) J.P. Corriou (LRGP) Process Control Zhejiang University 206 22 / 37

Proportional Action y Example of studies / Tracking : Assume step set point step of amplitude A 0.9 Kc=5 Kc=2 Y r(s) = A s ; D(s) = 0 (2) 0.8 0.7 0.6 Kc= Closed-loop response to a step set point is then equal to 0.5 0.4 0.3 0.2 0. Y(s) = K p K c A τ p s + +K p K c s = Final value theorem A s K p τ p s + (22) 0 0 2 3 4 5 6 7 8 9 0 Time lim t y(t) = lim s 0 sy(s) Kp Kc = A +K p K c (23) J.P. Corriou (LRGP) Process Control Zhejiang University 206 23 / 37

Proportional Action y 2/ Regulation : Assume disturbance point step of amplitude A 0.5 D(s) = A s ; Y r(s) = 0 (24) 0.4 0.3 0.2 0. Closed-loop response to a step disturbance is then equal to Y(s) = K d τ d s + Final value theorem τ ps + τ ps + +K pk c A s (25) 0 0 5 0 5 20 25 30 35 40 45 50 Time lim y(t) t = lim s 0 sy(s) K = d A +K p K c (26) J.P. Corriou (LRGP) Process Control Zhejiang University 206 24 / 37

Proportional Action Case of second-order systems Output Y(s) G p(s) = K p τ 2 p s 2 + 2ζ p τ p s + ; G d (s) = K d τ 2 d s2 + 2ζ d τ d s + (27) Y(s) = K p K c τp 2 s 2 Y r(s) + 2ζ p τ p s + +K p K c K + d τp 2 s2 + 2ζ p τ p s + τd 2 s2 + 2ζ d τ d s + τp 2 D(s) s 2 + 2ζ p τ p s + +K p K c (28) J.P. Corriou (LRGP) Process Control Zhejiang University 206 25 / 37

Proportional Action / Tracking Modification of period and damping factor τ p = τ p +Kp K c ζ p = ζ p +Kp K c (29) Steady-state gain K p = K p K c +K p K c (30) Same remarks as for first-order. a deviation between the set point and the asymptotic response exists which is all the more important as the gain is low. 2/ Regulation Same remarks as for first-order. J.P. Corriou (LRGP) Process Control Zhejiang University 206 26 / 37

Integral Action Even if integral action is never used alone, in order to characterize its influence, we first assume that the controller is pure integral G c(s) = Kc (3) τ I s Study of first-order systems. or K p K c +τ p s τ Y(s) = I s Y K p K r(s)+ c + + +τ p s τ I s Y(s) = τ p τ I s 2 + τ Y I r(s)+ s + K p K c K p K c Modification of the order in closed loop. K d τ d s + K d +τ d s K p +τ p s K c D(s) (32) τ I s (τ p s + )τ I s τ I τ p s 2 +τ I s + K p K c D(s) (33) J.P. Corriou (LRGP) Process Control Zhejiang University 206 27 / 37

Integral Action Y(s) = τ p τ I s 2 + τ Y I r(s)+ s + K p K c K p K c / Tracking, step set point of amplitude A K d τ d s + (τ p s + )τ I s τ I τ p s 2 +τ I s + K p K c D(s) (34) Y r(s) = A s (35) hence Final value theorem Y(s) = A τ p τ I s 2 + τ I s + K p K c K p K c s The integral action eliminates the asymptotic deviation. Response faster when gain is high, but oscillatory responses. (36) lim y(t) = lim[s Y(s)] = A (37) t s 0 J.P. Corriou (LRGP) Process Control Zhejiang University 206 28 / 37

Integral Action Y(s) = τ p τ I s 2 + τ Y I r(s)+ s + K p K c K p K c 2/ Regulation, step disturbance of amplitude A K d τ d s + (τ p s + )τ I s τ I τ p s 2 +τ I s + K p K c D(s) (38) D(s) = A s (39) hence Final value theorem Y(s) = K d τ d s + The integral action rejects step-like disturbances. (τ p s + )τ I s τ I τ p s 2 +τ I s + K p K c A s (40) lim y(t) = lim[s Y(s)] = 0 (4) t s 0 J.P. Corriou (LRGP) Process Control Zhejiang University 206 29 / 37

Derivative Action Transfer function of a pure ideal derivative controller is equal to G c(s) = K c τ D s (42) Improper transfer function (numerator degree larger than denominator degree). Block diagram of the ideal PID controller Block diagram of a real PID controller E(s) Kc τis τds + Ua(s) + + E(s) + Kc τis + τds τd N s+ Ua(s) J.P. Corriou (LRGP) Process Control Zhejiang University 206 30 / 37

Ideal Derivative Action Response Y(s) to a set point or disturbance variation Y(s) = = K p τ p s + Kc τ D s Y K r(s)+ p + τ p s + Kc τ D s + K p K c τ D s (τ p + K p K c τ D )s + Yr(s)+ K d τ d s + K d τ d s + K p τ p s + Kc τ D s D(s) τ p s + (τ p + K p K c τ D )s + D(s) (43) No influence on the system order. Closed-loop time constant τ p = τp + Kp Kc τ D (44) Closed-loop response will be slower than the open-loop one. Stabilization of the process. J.P. Corriou (LRGP) Process Control Zhejiang University 206 3 / 37

PI Controller Transfer function of PI Controller ( G c(s) = K c + ) τ I s (45) Output Y(s) = + ( K p +τ p s Kc + τ I s K p +τ p s Kc ) ( + τ I s ) Y r(s)+ + K d +τ d s K p +τ p s Kc ( + τ I s ) D(s) (46) or Y(s) = τ I s + Y τ p τ I s 2 K p K c + r(s)+ +τ I s + K p K c K p K c τ I s(+τ p s) K p K c K d τ d s + τ p τ I s 2 K p K c + +τ I s + K p K c K p K c Conclusions for the Integral action are still valid. D(s) (47) J.P. Corriou (LRGP) Process Control Zhejiang University 206 32 / 37

Summary of Controller Characteristics P controller : one tuning parameter K r, deviation from the set point, decreased by increasing gain. PI controller : elimination of the deviation between the asymptotic state and the set point, faster response, possible oscillations, possible saturation of control variable u. PID controller : same interest as PI, stabilizing effect, sensitivity to measurement noise. J.P. Corriou (LRGP) Process Control Zhejiang University 206 33 / 37

Influence of controller on first-order system y y y Response of a first-order system (K p = 5,τ p = 0) to a set point unit step. P controller PI controller Real PID controller 0.8 0.8 0.8 0.6 0.6 0.6 0.4 0.4 0.4 0.2 0.2 0.2 0 0 5 0 5 20 25 Time 0 0 5 0 5 20 25 Time 0 0 5 0 5 20 25 Time K c = 2 K c = 2 τ I = 20 K c = 2 τ I = 20 τ D = β = 0. J.P. Corriou (LRGP) Process Control Zhejiang University 206 34 / 37

Influence of controller on second-order system y y y response of a second-order system (K p = 5,τ p = 0,ζ p = 0.5) to a set point unit step. P controller PI controller Real PID controller 2 2 2.8.8.8.6.6.6.4.4.4.2.2.2 0.8 0.8 0.8 0.6 0.6 0.6 0.4 0.4 0.4 0.2 0.2 0.2 0 0 0 20 30 40 50 60 70 80 90 00 Time 0 0 0 20 30 40 50 60 70 80 90 00 Time 0 0 0 20 30 40 50 60 70 80 90 00 Time K c = 2 K c = 2 τ I = 20 K c = 2 τ I = 20 τ D = β = 0. J.P. Corriou (LRGP) Process Control Zhejiang University 206 35 / 37

Influence of controller on first-order system y y y Response of a first-order system (K p = 5,τ p = 0 : K d = 2,τ d = 2) to a disturbance unit step. P controller PI controller Real PID controller 0.5 0.5 0.5 0.4 0.4 0.4 0.3 0.3 0.3 0.2 0.2 0.2 0. 0. 0. 0 0 5 0 5 20 25 30 35 40 45 50 Time 0 0 5 0 5 20 25 30 35 40 45 50 Time 0 0 5 0 5 20 25 30 35 40 45 50 Time K c = 2 K c = 2 τ I = 20 K c = 2 τ I = 20 τ D = β = 0. J.P. Corriou (LRGP) Process Control Zhejiang University 206 36 / 37

Influence of controller on second-order system y y y Response of a second-order system (K p = 5,τ p = 0,ζ p = 0.5 : K d = 2,τ d = 2,ζ d = 0.25) to a disturbance unit step. P controller PI controller Real PID controller 2.5 2.5 2.5 2 2 2.5.5.5 0.5 0.5 0.5 0 0 0 0.5 0.5 0.5.5.5.5 2 2 2 2.5 0 0 20 30 40 50 60 70 80 90 00 Time 2.5 0 0 20 30 40 50 60 70 80 90 00 Time 2.5 0 0 20 30 40 50 60 70 80 90 00 Time K c = 2 K c = 2 τ I = 20 K c = 2 τ I = 20 τ D = β = 0. J.P. Corriou (LRGP) Process Control Zhejiang University 206 37 / 37