Studentská 1402/ Liberec 1 tel.: cxi.tul.cz. Analytic equipment

Similar documents
ICP-3000 Inductively Coupled Plasma Optical Emission Spectrometer

TOUR OF SOIL CHEMISTRY LABS (09/22/07)

AUTOMATED ONLINE IDENTIFICATION AND MONITORING OF IMPURITIES IN GASES

Partial Energy Level Diagrams

Research Equipment in the UCA Chemistry Department

PRINCIPLE OF ICP- AES

Atmospheric Analysis Gases. Sampling and analysis of gaseous compounds

RS DYNAMICS ECOPROBE 5. Portable IR/PID Gas Analyzer PID. PID and IR Analyzers


Agilent 7500a Inductively Coupled Plasma Mass Spectrometer (ICP-MS)

Ultra-fast determination of base metals in geochemical samples using the 5100 SVDV ICP-OES

VALLIAMMAI ENGINEERING COLLEGE SRM Nagar, Kattankulathur

UNIVERSITI SAINS MALAYSIA. Second Semester Examination Academic Session 2004/2005. March KAA 502 Atomic Spectroscopy.

Application Note S/SL

OES - Optical Emission Spectrometer 2000

UV3000. Accurate, precise, and portable ambient gas point analyzer

Product Descriptions and Offerings

White Paper. Overview: NDIR Definition:

The Analysis of Trace Contaminants in High Purity Ethylene and Propylene Using GC/MS. Application. Agilent Technologies/Wasson ECE Monomer Analyzer

Introduction to Pharmaceutical Chemical Analysis

a. An emission line as close as possible to the analyte resonance line

Supporting Information. Synthesis of Mg/ Al Layered Double Hydroxides for Adsorptive Removal of. Fluoride from Water: A Mechanistic and Kinetic Study

Supporting Information

ICP-Mass Spectrometer

NON-METHANE ORGANIC CARBON ANALYZER (NMOC Method 25)

The Agilent 7700x ICP-MS Advantage for Drinking Water Analysis

10/2/2008. hc λ. νλ =c. proportional to frequency. Energy is inversely proportional to wavelength And is directly proportional to wavenumber

Analysis Repeatability of Trace and Major Elements in a Water Sample

FLAME PHOTOMETRY AIM INTRODUCTION

atomic absorption spectroscopy general can be portable and used in-situ preserves sample simpler and less expensive

ICP-OES Application Note Number 35

ADVANCED ANALYTICAL LABORATORY

CHAPTER 4: ANALYTICAL INSTRUMENTATION

NATURE AN POLUUTION DEGREE OF WATER ASSETS STUDIED BY INDUCTIVELY COUPLED PLASMA-OPTICAL EMISSION SPECTROSCOPY

110 Lowell Rd Hudson, NH USA Tel:

NaturalFacts. Introducing our team. New product announcements, specials and information from New Roots Herbal. April 2009

Monomer Analysis. Analysis by Gas Chromatography WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Real-time ppb CO 2 Impurity Detection by an Advanced FTIR- UVF System

The Investigation of Fertilizer Analyses Using Microwave Digestion and the Agilent 720-ES

AN INTRODUCTION TO ATOMIC SPECTROSCOPY

Luminescence transitions. Fluorescence spectroscopy

Determination the elemental composition of soil samples

Direct Measurement of Metallic Impurities in 20% Ammonium Hydroxide by 7700s/7900 ICP-MS

ENVG FALL ICP-MS (Inductively Coupled Plasma Mass Spectrometry) Analytical Techniques

Hydride Generation for the Determination of As, Sb, Se and Bi Using the Teledyne Leeman Lab s Prodigy 7 ICP-OES

النسيف والتخثر / Bleeding and clotting الطب. علن االدوية / Pharmacology. اآلحيبء الذقيقة والونبعة Microbiology and / Immunology

Scientific Instruments

Reprinted from February Hydrocarbon

of mass spectrometry

Atomic Spectroscopy AA/ICP/ICPMS:

Final Exam. Physical Constants and Conversion Factors. Equations

MT Electron microscopy Scanning electron microscopy and electron probe microanalysis

The Low-Temperature Evaporative Light-Scattering Detector (LT-ELSD)

WP3: In-situ chemical, physical and optical properties of aerosols. WP4: Trace gases networking: Volatile organic carbon and nitrogen oxides

Sandro Guidi, Marco Noè, Pietro Riello, Alvise Perosa and Maurizio Selva

The Claviature of Gas Analysis

Measurement Technique and its Application to Trace Components of Atmospheric Gas

Fast Analysis of Water Samples Comparing Axially-and Radially- Viewed CCD Simultaneous ICP-OES

Innovative. Intuitive. Concentration (ppb) R = Versatile. Hydra II C Mercury Analyzer

U.S. EPA SW-846 Method 6010C using the Prodigy High Dispersion ICP

Determination of major, minor and trace elements in rice fl our using the 4200 Microwave Plasma- Atomic Emission Spectrometer (MP-AES) Authors

RESOLUTION OENO 33/2004 DETERMINATION OF SHIKIMIC ACID IN WINE BY HPLC AND UV-DETECTION

CHEM 3590 Final examination 2017 Instructor : Dr. Hélène Perreault Monday December 11, 1:30-4:30 pm, Frank Kennedy Gold Gym seats


Enhancing the productivity of food sample analysis with the Agilent 7700x ICP-MS

C (s) + O 2 (g) CO 2 (g) S (s) + O 2 (g) SO 2 (g)

Elemental analysis of river sediment using the Agilent 4200 MP-AES

GAS CHROMATOGRAPHY (GC)

2101 Atomic Spectroscopy

TL6 Ultra Micro-volume Spectrophotometer

How many hydrogen atoms are there in the empirical formula of propene, C 3 H 6? How many neutrons are there in one atom of 24 Mg?

Key Analytical Issues: Sample Preparation, Interferences and Variability. Tim Shelbourn, Eli Lilly and Company

M.Sc. (Final) DEGREE EXAMINATION, DECEMBER Second Year Chemistry Paper V ANALYTICAL CHEMISTRY. PART A (4 10 = 40 marks)

MASTERING THE VCE 2014 UNIT 3 CHEMISTRY STUDENT SOLUTIONS

SmartNotes. What is meant by the term interference?

high temp ( K) Chapter 20: Atomic Spectroscopy

Prima PRO Process Mass Spectrometer

Litesizer Sheet 1. [Home]

CHEM 221 Instrumental Analysis FINAL EXAM May 10, 2016

Lecture 7: Atomic Spectroscopy

A Newly Approved ASTM Standard For Analysis of Thiophene in Benzene Using a Pulsed Flame Photometric Detector (PFPD)

Chapter 9. Atomic emission and Atomic Fluorescence Spectrometry Emission spectrophotometric Techniques

Determination of the Halogen Elements in the Deep UV Region of the Spectrum by ICP - OES

TOXICOLOGY & FORENSIC APPLICATIONS

Atomic Absorption Spectroscopy and Atomic Emission Spectroscopy

Multi-residue analysis of pesticides by GC-HRMS

Final Report. Characterisation of Sample Report. Job No 2016/11/12-34 AS No. 1234A. Client Example Contact Sample. Signed Date 2017.

Petrochemical. Transformer Oil Gas Analysis - TOGA

Spectroscopy. Practical Handbook of. J. W. Robinson, Ph.D., D.Sc, F.R.C.S. Department of Chemistry Louisiana State University Baton Rouge, Louisiana

Emission spectrum of H

Trace Analysis of Hexavalent Chromium using IC-ICP-DRC-MS

Pittcon External Seminar Template X-ray Analysis in Petrochemical Industry: Challenges and Solutions

CH. 21 Atomic Spectroscopy

Elemental Analysis: CHNS/O characterization of polymers and plastics

Dissolution Automation: Basic Questionnaire.

Arsenic and Other Trace Elements in Groundwater in the Southern San Joaquin Valley of California

Peter L Warren, Pamela Y Shadforth ICI Technology, Wilton, Middlesbrough, U.K.

VALIDATION STUDY OF FTIR-BASED EMISSIONS MEASUREMENTS AT A MUNICIPAL WASTE COMBUSTOR

Application of Raman Spectroscopy for Noninvasive Detection of Target Compounds. Kyung-Min Lee

ANALYTICAL METHOD DETERMINATION OF VOLATILE ALDEHYDES IN AMBIENT AIR Page 1 of 11 Air sampling and analysis

Transcription:

Analytic equipment

Department of vehicles and engines Horiba Mexa-9430H, 9100H Exhaust gas analyzers Emission analyzers (HORIBA MEXA-9430H, 9100H) Emissions analyzers with analytical modules NGA, includes: Process Multi-Method Channel Analyzer (MLT 1)

Department of vehicles and engines FTIR spectrometer Nicolet Antaris IGS Spectrometer Possibility to analyze a gas solutions Spectral range 6 000-650 cm -1 Continuous quantitative analysis showing up to hundred components of gas at a time Possibility to extend the analysis of liquids and solids Water Carbon Dioxide Methane Carbon Monoxide Nitric Oxide Nitrogen Dioxide Nitrous Oxide Amonia Ethane Ethene Acetylene Propane Propene 1,3 Butadiene IsoButylene Formaldehyde Acetaldehyde Formaldehyde Sulfur Dioxide NOx CO

Department of preparation and analysis of nanostructures Oxford AZtec Analysis of chemical composition Part of SEM system EDS System AztecEnergy X-Max detector Quality and quantity analysis of local chemical composition (from Be to Pu) WDS System - INCAWave INCAWave 500 Ultra-precision analysis of local chemical composition Radius from 0,17 to 10,84 kev EBSD System - AZtecHKL HKL NordlysNano Crystalographic information

Department of vehicles and motors Domena B3, Domena Promag, Domena NC Magnetic structure-scoping Technical parameters: Magnetic metals Magnetic spot method Measurement time 3-5 sec Magnetic hardness tester Measurement of perlit, ferrit, martensit, bainit Degradation and deformation of austenitic steels

Department of industrial technology CCD spectrometer Q4 Tasman Precise multi-base optical emission spectrometer Technical parameters: Optical system Dual CCD Detectors are new type CCD detectors without coating with smaller pixels. Continual spectrum cover Focus range 500 mm / Paschen Runge Wave length range 130 nm to 620 nm. This wave length range enables and encourages N in FE matrix from 25 ppm and analysis of P in Al matrix from 10 ppm. Calibration matrix Al, Fe, Cu, Mg, Zn, Ti a Ni Fully digital spark optical emission spectrometer with digital Bit-Stream plasma generator and double CCD optical system. Designed for routine analysis of smelting plants, laboratories and quality control labs. Tasman is full immune against changes in outside temperature.

(HPLC)- ICP-MS NexION 3000D, Perkin Elmer Mass spectrometer with inductively coupled plasma Connection possibility of HPLC enables specialization of selected elements Collisional reaction cell for matrix interference removal Assessment possibility of most elements in periodic table, in ultra-trace concentration Detection limits from 0,5 ppt

ICP-OES OPTIMA 2100 DV, Perkin Elmer Emission spectrometer Emission spectrometer with inductively coupled plasma Axial and radial plasma observation Range 160 900 nm Possibility of peak deconvolution Assessment of most elements in periodic table even in trace amounts Detection limits in tenth of ppb Connection possibility of hydroid (As, Se, Sb, )

ICS-90, Dionex Ion chromatograph Device for ion analysis in modification for assessment of standard ions (Cl -, F -, NO 3 -, NO 2 -, SO 4 2-, PO 4 3- ) in water solutions ranging from ph 0-14 With manual injection Range of detection 0,5 mg/l Technical parameters: Isocratic pump Conductivity detector (0 10 ms)

GC MS MS Quadrupole spectrometer Assessment of : Residual pesticides Hormonal disruptors All in ultra-trace concentrations Used in municipal, industrial and drinking water analysis Assessment possibility of whole range of other analytes, by the need of research programs and customer requirements

GC/MS/FID Saturn 2200, Varian Gas chromatograph Gas chromatograph with: Mass detector Flame ion detector Auto-sampler Combi-Pal for dosage of fluid samples even for head-space technique Routine assessments: Volatile organic compounds Pesticides Assessment possibility of whole range of other analytes, by the need of research programs and customer requirements

GC/FID Autosystem XL, Perkin Elmer Gas chromatograph Gas chromatograph with two flame-ion detector Possibility of conducting a confirmation analysis simultaneously in two columns with different phases Auto-sampler for dosage of fluid samples Routine assessment: C 10 -C 40 Possibility of implementation of next analysis by the need of research programs or customer requirements

GC/FID/TCD Clarus, Perkin Elmer Gas chromatograph Gas chromatograph with: Thermal conduction detector Flame-ionization detector Possibility of on-line analysis of gas samples Possibility of kinetic event study in closed systems with gas phase

HPLC UltiMate 3000, Dionex Fluid chromatograph Fluid chromatograph with detector: UV/VIS ELSD Pump with quaternary gradient Routine analysis: Analysis of organic acids Analysis of surface active compounds Possibility of assessment of whole range of other analytes by the need of research projects of customer requirements

Real-Time PCR Measurement of gene expression Measures the amount of cdna or mrna in a sample, either from a population of cells or a single cell Used in the detection of pathogens in the blood such as viruses Can be used to compare normal (control) samples to disease samples, giving an idea as to expression changes which occur with pathogenesis 16S or 18S rrna Automatic data storage

Sequenator Gene sequencing Measurement of nucleotide sequencing in molecules of nucleotide acids Sequence of gene Screening of mutations Identification of organisms Identification of transcripts

Next generation sequencing Gene sequencing Measurement of nucleotide sequencing in molecules of nucleotide acids Sequence of gene Screening of mutations Identification of organisms Identification of transcriptors

DR 2800, Hach-Lange Spectrophotometer Technical data: Transportable photometer for laboratory and field Range of wave-length 340 900 nm Width of rift 5 nm Working mode: Penetrability, absorption, concentration 50 user programs Programs for bar code Adapter: Classic 1 cm, 5 cm, Circular diameter 13 mm Cuvetter tests Hach-Lange

Spectrophotometer DR 2900, Hach-Lange Spectrophotometer Technical data: Photometer UV/VIS for lab work Range of wave lengths 340 900 nm With of the rift 5 nm Working modes: Penetrability, absorption, concentration One wave length, move wave lengths, scan, timescale 50 user programs Programs with bar codes Adapter: Classic 1 cm, 5 cm, Circular diameter 13 mm Cuvetter tests Hach-Lange

LT 200, Hach-Lange Digital thermo-reactor For standard decomposition of CHSK, TOC, P and heavy metals for cuvette tests Preset temperature modes even for possibility of ones own programing Cuvette tests Hach-Lange (bar codes for differentiation of assessed compound and concentration range For general photometric assessment F -, NO 3 -, NO 2 -, SO 4 2-, PO 4 3-, CHSK, TOC, Fe 2+/ Fe 3+, AOX, fenols )

Lambda 35, Perkin Elmer UV/VIS spectrophotometr Technical parameters: 190 1100 nm Two-ray Width of the rift 0,5-4 nm Operation modes: Kinetics Concentration Spectral More wave lengths Cuvettes: Continuous 10 mm Standard to the length of 100 mm

Zetasizer ZS, Malvern High performance two angle particle and molecular size analyzer Device for measurement: Size of particles by method DLS (laser 633nm), from 0,6 nm 6 µm Molecular weight by method SLS, from 1000-2x107 u Zeta potential by method Laser Doppler electrophoresis, from 5 nm 10 µm Auto-titration MPT-2 One-shot plastic, even silicon measuring cell