Atomic and nuclear physics

Similar documents
Atomic and nuclear physics

Atomic and nuclear physics

Andrew D. Kent. 1 Introduction. p 1

Solid-state physics. Laue diagrams: investigating the lattice structure of monocrystals. LEYBOLD Physics Leaflets P

CASSY Lab. Manual ( )

Determination of the Rydberg constant, Moseley s law, and screening constant (Item No.: P )

Lab Manual: Determination of Planck s constant with x-rays

Bragg reflection :determining the lattice constants of monocrystals

Absorption of X-rays

This experiment is included in the XRP 4.0 X-ray solid state, XRS 4.0 X-ray structural analysis, and XRC 4.0 X-ray characteristics upgrade sets.

Atomic and nuclear physics

TEP Examination of the structure of NaCl monocrystals with different orientations

Characteristic X-rays of molybdenum

X-RAY SPECTRA. Theory:

Optics. Measuring the line spectra of inert gases and metal vapors using a prism spectrometer. LD Physics Leaflets P

Physical Structure of Matter. K a doublet splitting of molybdenum X-rays / fine structure Physics of the Electron.

X-ray Absorption Spectroscopy


Electricity. Measuring the force on current-carrying conductors in a homogeneous magnetic field. LEYBOLD Physics Leaflets P

Physical structure of matter. Duane-Hunt displacement law and Planck's quantum of action X-ray Physics. What you need:

X-ray spectroscopy: Experimental studies of Moseley s law (K-line x-ray fluorescence) and x-ray material s composition determination

Atomic and nuclear physics

X-Rays Edited 2/19/18 by DGH & Stephen Albright

X-ray Spectroscopy. Danny Bennett and Maeve Madigan. October 12, 2015

X-ray absorption. 4. Prove that / = f(z 3.12 ) applies.

Physics 476LW. Advanced Physics Laboratory - Franck Hertz

TEP K and L edge absorption Moseley s law and the Rydberg constant

Atomic and Nuclear Physics

Mechanics. Determining the gravitational constant with the gravitation torsion balance after Cavendish. LEYBOLD Physics Leaflets P

X-ray Spectroscopy. c David-Alexander Robinson & Pádraig Ó Conbhuí. 14th March 2011

X-ray fluorescence analysis - calibration of the X-ray energy detector

X-RAY SCATTERING AND MOSELEY S LAW. OBJECTIVE: To investigate Moseley s law using X-ray absorption and to observe X- ray scattering.

X-ray practical: Crystallography

Atomic and Nuclear Physics

p tot Mechanics LD Physics Leaflets

Atomic Spectra HISTORY AND THEORY

Jazan University College of Science Physics Department. Lab Manual. Nuclear Physics (2) 462 Phys. 8 th Level. Academic Year: 1439/1440

PC1144 Physics IV. Atomic Spectra

Experiment 6 1. The Compton Effect Physics 2150 Experiment No. 6 University of Colorado

Alpha-Energies of different sources with Multi Channel Analyzer

Measuring Planck s Constant By Martin Hackworth

UNIVERSITY OF SURREY DEPARTMENT OF PHYSICS. Level 1: Experiment 2F THE ABSORPTION, DIFFRACTION AND EMISSION OF X- RAY RADIATION

Experiment objectives: measure the ratio of Planck s constant to the electron charge h/e using the photoelectric effect.

Alpha-energies of different sources with Multi Channel Analyzer (Item No.: P )

Chemistry Instrumental Analysis Lecture 19 Chapter 12. Chem 4631

PiCUS Calliper Version 3

product manual H-3220A Benkelman Beam

Laboratory #29: Spectrometer

Circular Motion and Centripetal Force

Relativistic Electrons

X-Ray Emission and Absorption

Lab 5: Spectroscopy & the Hydrogen Atom Phy248 Spring 2009

Photoelectric Effect

Sample Alignment (2D detector) Part

Beamline practice at BL01B1 (XAFS) In-situ XAFS measurement of catalyst samples

Lab 10 Circular Motion and Centripetal Acceleration

The University of Hong Kong Department of Physics

Physics 476LW Advanced Physics Laboratory Atomic Spectroscopy

Modern Physics Laboratory MP2 Blackbody Radiation

!!!!! General!Physics!I!&!II!Lab!!! Course!Description!! Lab!Report!Template!and!Sample!! Grading!Rubrics! Pre>Lab!Quizzes!!!!!!!!

hν' Φ e - Gamma spectroscopy - Prelab questions 1. What characteristics distinguish x-rays from gamma rays? Is either more intrinsically dangerous?

Free fall with an interface system

Higher -o-o-o- Past Paper questions o-o-o- 3.6 Radiation

PHYSICS A2 UNIT 2 SECTION 1: RADIOACTIVITY & NUCLEAR ENERGY

Radioactivity INTRODUCTION. Natural Radiation in the Background. Radioactive Decay

Software BioScout-Calibrator June 2013


Ph 3455/MSE 3255 Experiment 2: Atomic Spectra

Revision Guide. Chapter 7 Quantum Behaviour

Praktikum zur. Materialanalytik

print first name print last name print student id grade

h/e Apparatus h/e Apparatus Accessory Kit

Sample Alignment Part

LAB 01 X-RAY EMISSION & ABSORPTION

Pracownia Podstaw Fizyczne Laboratorium Mikrokomputerowe Wydział Fizyki Eksperymentu Fizycznego Filami UAM. Radioactive decay

MASS ATTENUATION COEFFICIENT OF LEAD

The Spectrophotometer and Atomic Spectra of Hydrogen Physics 246

DAY LABORATORY EXERCISE: SPECTROSCOPY

Experiment C-10 Titration of a Strong Acid and a Strong Base

4. Inelastic Scattering

RADIOACTIVITY MATERIALS: PURPOSE: LEARNING OBJECTIVES: DISCUSSION:

Physics 23 Fall 1989 Lab 5 - The Interaction of Gamma Rays with Matter

EMISSION SPECTROSCOPY

Absorption of Gamma Rays

Rutherford experiment with MCA

EQUIPMENT Beta spectrometer, vacuum pump, Cs-137 source, Geiger-Muller (G-M) tube, scalar

Lab NUC. Determination of Half-Life with a Geiger-Müller Counter

A) m B) m C) m D) m E) m. 5. Which one of the following circuits has the largest resistance?

Coherence and width of spectral lines with Michelson interferometer

Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy. Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy

CHAPTER 1 RADIATION AND RADIOACTIVITY

The Photoelectric Effect and the Quantization of Light

THE NATURE OF THE ATOM. alpha particle source

Physics 1C OPTICAL SPECTROSCOPY Rev. 2-AH. Introduction

INVESTIGATION OF THE DEGREE OF PERFECTION OF A CRYSTAL BY MEANS OF POLARIZED X-RAYS BY S. RAMASESHAN AND G. N. RAMACHANDRAN, F.A.Sc.

Higher Physics. Particles and Waves

Lab 10: Spectroscopy & the Hydrogen Atom Phy208 Fall 2008

SC125MS. Data Sheet and Instruction Manual. ! Warning! Salem Controls Inc. Stepper Motor Driver. Last Updated 12/14/2004

Chapter 37 Early Quantum Theory and Models of the Atom

NE01 - Centripetal Force. Laboratory Manual Experiment NE01 - Centripetal Force Department of Physics The University of Hong Kong

Transcription:

Atomic and nuclear physics X-ray physics Physics of the atomic shell LEYBOLD Physics Leaflets Moseley s law and determination of the Rydberg constant P6.3.3.6 Objects of the experiment Measuring the K-absorption edges in the transmission spectra of Zr, Mo, Ag and In. Verifying Moseley s law. Determining the Rydberg constant. Principles The absorption of x-ray quanta during the passage of x-rays through matter is essentially due to ionization of atoms, which release an electron from an inner shell, e.g. the K-shell. This can only occur when the quantum energy E = h c (I) h: Planck s constant, c: velocity of light is greater than the binding energy E K of the shell. The transmission of the material thus increases abruptly as a function of the wavelength at K = h c (III) E K This abrupt change is known as an absorption edge, here the K-absorption edge. In 1913, the English physicist Henry Moseley measured the K-absorption edges for various elements and formulated the law that bears his name: 0508-Ste T = R R 0 R: intensity rate behind attenuator R 0 : intensity in front of attenuator Fig. 1 Binding energy of the K-shell in the form E K h c R as a function of the atomic number Z (see also equation (V)) Circles: Literature values from [1] Line: best-fit straight line for Z = 30 60 (II) 1 = R (Z K ) (IV) K R: Rydberg constant Z: atomic number of absorbing elements K : screening coefficient of K-shell A comparison with (III) gives us a value for the binding energy of the K-edge of E K = h c R (Z K ) 2 (V) We can bring this equation into agreement with the predictions of Bohr s model of the atom when we consider the following: The nuclear charge Z e of an atom is partially screened from the electron ejected from the K-shell through absorption of the x-ray quantum by the remaining electrons of the atomic shell. Therefore, on average, only the charge (Z K ) e acts on the electron during ionization. This experiment verifies Moseley s law by measuring the K-absorption edges for the atomic numbers Z between 40 and 50. In this range, the screening coefficient K is largely independent of Z (see Fig. 1). Thus, (IV) is equivalent to a general, straight-line equation in the form y = a x + b (VI) with the atomic number Z as the x-variable. From the parameters a and b of the straight line, we can calculate the Rydberg constant R and the screening coefficient K : R = a 2, K = b a (VII). 1

P6.3.3.6 LEYBOLD Physics Leaflets Apparatus 1 X-ray apparatus.............. 554 811 1 End-window counter for,, and x-ray radiation...... 559 01 1 Set of absorber foils........... 554 832 additionally required: 1 PC with Windows 9x/NT A goniometer with NaCl crystal and a Geiger-Müller counter tube in the Bragg configuration are used to measure the transmission T as a function of the wavelength. The crystal and counter tube are pivoted with respect to the incident x-ray beam in 2 coupling, i.e. the counter tube is turned at an angle twice as large as the crystal (see Fig. 2). In accordance with Bragg s law of reflection, the scattering angle in the first order of diffraction corresponds to the wavelength = 2 d sin (VIII). d = 282.01 pm: lattice plane spacing of NaCl Safety notes The x-ray apparatus fulfills all regulations governing an x-ray apparatus and fully protected device for instructional use and is type approved for school use in Germany (NW 807/97 Rö). The built-in protection and screening measures reduce the local dose rate outside of the x-ray apparatus to less than 1 Sv/h, a value which is on the order of magnitude of the natural background radiation. Before putting the x-ray apparatus into operation inspect it for damage and to make sure that the high voltage is shut off when the sliding doors are opened (see Instruction Sheet for x-ray apparatus). Keep the x-ray apparatus secure from access by unauthorized persons. Do not allow the anode of the x-ray tube Mo to overheat. When switching on the x-ray apparatus, check to make sure that the ventilator in the tube chamber is turning. The goniometer is positioned solely by electric stepper motors. Do not block the target arm and sensor arm of the goniometer and do not use force to move them. Fig. 2 Setup Schematic diagram of diffraction of x-rays at a monocrystal and 2 coupling between counter-tube angle and scattering angle (glancing angle) 1 collimator, 2 monocrystal, 3 counter tube Setup in Bragg configuration: Set up the experiment as shown in Fig. 3. To set up the experiment, proceed as follows (see also the Instruction Sheet for the x-ray apparatus): Mount the collimator in the collimator mount (a) (note the guide groove). Attach the goniometer to guide rods (d) so that the distance s 1 between the slit diaphragm of the collimator and the target arm is approx. 5 cm. Connect ribbon cable (c) for controlling the goniometer. Remove the protective cap of the end-window counter, place the end-window counter in sensor seat (e) and connect the counter tube cable to the socket marked GM TUBE. By moving the sensor holder (b), set the distance s 2 between the target arm and the slit diaphragm of the sensor seat to approx. 5 cm. Mount the target holder with target stage. Loosen knurled screw (g), place the NaCl crystal flat on the target stage (f), carefully raise the target stage with crystal all the way to the stop and carefully tighten the knurled screw (prevent skewing of the crystal by applying a slight pressure). If necessary, adjust the mechanical zero position of the goniometer (see Instruction Sheet for x-ray apparatus). Notes: NaCl crystals are hygroscopic and extremely fragile. Store the crystals in a dry place; avoid mechanical stresses on the crystal; handle the crystal by the short faces only. If the counting rate is too low, you can reduce the distance s 2 between the target and the sensor somewhat. However, the distance should not be too small, as otherwise the angular resolution of the goniometer is no longer sufficient to separate the characteristic K and K lines. 2

LEYBOLD Physics Leaflets P6.3.3.6 Fig. 3 Experiment setup for measuring the K-absorption edges. Carrying out the experiment Start the software X-ray Apparatus, check to make sure that the apparatus is connected correctly, and clear any existing measurement data using the button or the F4 key. Set the tube high voltage U = 35.0 kv, the emission current I = 1.00 ma and the angular step width = 0.1. Press the COUPLED key to activate 2 coupling of target and sensor and set the lower limit of the target angle to 3.7 and the upper limit to 7.5. Set the measuring time per angular step to t = 5 s. Start measurement and data transfer to the PC by pressing the SCAN key. When the scan is finished, mount the zirconium foil on sensor seat (e) of the goniometer and start a new measurement by pressing the SCAN key. Replace the Zr foil with the Mo, Ag and In foils one after another and conduct further measurements. When you have finished measuring, save the measurement series under an appropriate name by pressing the button or the F2 key. Preparing the PC-based measurement: Connect the RS 232 output and the serial interface on your PC (usually COM1 or COM2) using the 9-pin V.24 cable (supplied with x-ray apparatus). If necessary, install the software X-ray Apparatus under Windows 9x/NT (see Instruction Sheet for x-ray apparatus) and select the desired language. To display the measurement data as a function of the wavelength, open the Settings dialog with the button or F5, and in the tab Crystal, click on the button Enter NaCl. Measuring example (see Fig. 4) Fig. 4 Diffraction spectra of x-rays with the characteristic lines of the molybdenum anode in the wavelength range between 36 and 74 pm (U = 35 kv) Squares: Not attenuated Triangles: Attenuation in Zr foil Circles: Attenuation in Mo foil Hashes: Attenuation in Ag foil Squares: Attenuation in In foil 3

P6.3.3.6 LEYBOLD Physics Leaflets Evaluation Click on the Transmission tab in the software X-ray Apparatus to generate the transmission spectra (see Fig. 5) from the diffraction spectra (see Fig. 4). In the diagram, click the right mouse button to access the evaluation functions of the software X-ray Apparatus and select the command Draw K-Edges. Mark the range of each K-edge in the transmission spectra using the left mouse button. Click on the tab Moseley and enter the atomic numbers of the respective foils (Zr: 40, Mo: 42, Ag: 47 and In: 49) in the column Z (see Fig. 6). Place the mouse pointer over the diagram, click the right mouse button and select the evaluation command Best-fit Straight Line ; then hold down the left mouse button to mark the range in the diagram to which you want to fit the line. Read off the result for the Rydberg constant R and the screening coefficient K in the bottom left corner of the window. Fig. 6 shows how the result should look. Fig. 5 Transmission spectra in the wavelength range between 36 and 74 pm Triangles: Attenuation in Zr foil Circles: Attenuation in Mo foil Hashes: Attenuation in Ag foil Squares: Attenuation in In foil Fig. 6 Evaluation of measurement data for verification of Moseley s law 4

LEYBOLD Physics Leaflets P6.3.3.6 Results The result of the graphical evaluation is: R = 1.082 10 7 m 1, K = 3.2 Literature values [1]: R = 1.097373 10 7 m 1 K = 3.6 (for moderately heavy nuclei) Literature [1] C. M. Lederer and V. S. Shirley, Table of Isotopes, 7th Edition, 1978, John Wiley & Sons, Inc., New York, USA. LEYBOLD DIDACTIC GMBH Leyboldstrasse 1 D-50354 Hürth Phone (02233) 604-0 Telefax (02233) 604-222 Telex 17 223 332 LHPCGN D by Leybold Didactic GmbH Printed in the Federal Republic of Germany Technical alterations reserved