Spatial resolution of a MPGD TPC using the charge dispersion signal

Similar documents
Spatial Resolution of a Micromegas-TPC Using the Charge Dispersion Signal

Spatial Resolution of a Micromegas-TPC Using the Charge Dispersion Signal

Measurement of MPGD-TPC resolution with charge dispersion in a beam test in a magnet

Simulating the Charge Dispersion Phenomena in Micro Pattern Gas Detectors with a Resistive Anode

Results with Micromegas modules at LP-TPC

arxiv:physics/ v2 [physics.ins-det] 31 Oct 2003

Track Resolution Measurements for a Time Projection Chamber with Gas Electron Multiplier Readout

Investigation of GEM space point resolution for a TPC tracker

Study of GEM-TPC Performance in Magnetic Fields

Tracking in a TPC. D. Karlen / U. Victoria & TRIUMF for the LCTPC collaboration

Near detector tracker concepts. D. Karlen / U. Vic. & TRIUMF T2K ND280m meeting August 22, 2004

Status and Challenges of CEPC Time Projection Chamber Detector. Huirong On behalf of CEPC Tracking Subgroup

Development of a Time Projection Chamber with GEM technology in IMP. Herun yang Gas detector group

Hybrid Gaseous Detector Module for CEPC-TPC

ATLAS New Small Wheel Phase I Upgrade: Detector and Electronics Performance Analysis

GEM upgrade of the ALICE TPC. Markus Ball Physics Department E18 Technische Universität München On Behalf of the ALICE TPC upgrade

Near Detector Tracker. Dean Karlen / U. Victoria & TRIUMF NP04 Neutrino Session - KEK August 25, 2004

Precision Calibration of Large Area Micromegas Detectors Using Cosmic Muons

Beam Test of a MPGD-Readout TPC in a B-Field

PoS(EPS-HEP2015)232. Performance of a 1 m 2 Micromegas Detector Using Argon and Neon based Drift Gases

Detecting low energy recoils with Micromegas

Electron transparency, ion transparency and ion feedback of a 3M GEM

An estimation of the effective number of electrons contributing to the coordinate measurement with a TPC II

HARPO: Measurement of polarised gamma rays (1.7 to 72MeV) with the HARPO TPC

R&D and related Simulation Studies for the sphenix Time Projection Chamber

TPC studies using GEM and Micromegas readouts,

A proposal to study gas gain fluctuations in Micromegas detectors

A Complete Simulation of a Triple-GEM Detector

Part II. Momentum Measurement in B Field. Contribution from Multiple Scattering. Relative Momentum Error

Test-bench for the Characterization of MicroMegas Modules for the T2K ND280 TPC

Lecture 18. New gas detectors Solid state trackers

Improvement of Spatial Resolution by Selfconsistent Full Muon Track Reconstruction in Gaseous Detectors

Bulk Micromegas detectors for large TPC applications

TPC-like analysis for thermal neutron detection using a GEMdetector

mean free path stopping power absorption coefficient detected recoil rate detected 0νββ events

Momentum Measurement in B Field. Part II. Relative Momentum Error. Contribution from Multiple Scattering

A complete simulation of a triple-gem detector

Particle Energy Loss in Matter

Gaseous and gasless pixel detectors

arxiv: v1 [physics.ins-det] 28 Mar 2016

Performance of a triple-gem detector for high-rate particle triggering

Micromegas detectors & the Great Pyramid. S. Procureur

Les Premières Données dans ATLAS et le Calorimètre à Argon Liquide

Study of the HARPO TPC for a high angular resolution g-ray polarimeter in the MeV-GeV energy range. David Attié (CEA/Irfu)

Simulations of MPD Straw End-Cap Tracker. Jan Fedorishin, XXII International Baldin Seminar on High Energy Physics Problems, September 19, 2014

GEM at CERN. Leszek Ropelewski CERN PH-DT2 DT2-ST & TOTEM

Study of GEM-TPC for ILC in Japan

Technology Comparison: brief update

The Cylindrical GEM detector for the KLOE-2 Inner Tracker

Solid State Detectors

Commissioning of the ATLAS LAr Calorimeter

Detectors in Nuclear and High Energy Physics. RHIG summer student meeting June 2014

Neutron Structure Functions and a Radial Time Projection Chamber

ACTAR TPC: an active target and time projection chamber for nuclear physics

Tracking detectors for the LHC. Peter Kluit (NIKHEF)

Activity report of ILD-TPC Asia group

Micro Pixel Chamber Operation with Gas Electron Multiplier

Content. Complex Detector Systems. Calorimeters Velocity Determination. Semiconductor detectors. Scintillation detectors. Cerenkov detectors

Interaction of particles in matter

for the HARPO Collaboration: *

Rate Dependency Study on Gas Electron Multiplier Gain

Performance studies of MicroMegas for the ATLAS experiment

Status and Plans of the Large TPC Prototype for the ILC

A new detector for neutron beam monitoring

ATLAS Hadronic Calorimeters 101

Advantages / Disadvantages of semiconductor detectors

Particle ID in ILD. Masakazu Kurata, KEK Calorimeter Workshop IAS program 01/19/2018

Advances in the Micro-Hole & Strip Plate gaseous detector

Recent developments on Micro-Pattern Gaseous Detectors

Introduction. Tau leptons. SLHC. Summary. Muons. Scott S. Snyder Brookhaven National Laboratory ILC Physics and Detector workshop Snowmass, Aug 2005

Construction of time-projection chambers to probe the symmetry energy at high density. R. Shane, for the SAMURAI-TPC collaboration

The LHC Experiments. TASI Lecture 2 John Conway

Discharge studies in Micromegas detectors in low energy hadron beams

The simulation of the Electron Tracking Compton Camera with a gaseous time projection chamber and a scintillator

Alice TPC particle identification

BEGe Detector studies update

Particle Energy Loss in Matter

arxiv:physics/ v1 [physics.ins-det] 23 Nov 2006

CALICE scintillator HCAL

Chung-Yao Chao Fellowship Interview

Experimental Particle Physics

Test setup, APDs,, preamps Calibration procedure Gain monitoring with LED Beam test results Future R&D options

Tracking 3 Gaseous Detectors

The ultimate resolution drift chamber

A Triple-GEM Telescope for the TOTEM Experiment

NEWAGE. Kentaro Miuchi (Kyoto University) (New generation WIMP search with an advanced gaseous tracker experiment)

B. Sitar G. I. Merso n V. A. Chechin Yu. A. Budagov. Ionization Measurement s in High Energy Physics

LArTPC R&D status. 2015/Aug./5, Workshop for Neutrino Programs with facilities in Japan Ken Sakashita (KEK/J-PARC)

Experimental Particle Physics

arxiv: v2 [nucl-ex] 6 Oct 2008

DETECTORS: PERFORMANCES AND APPLICATIONS Fabio SAULI MPGD WORKSHOP CERN, January 20, 2006

Particle Detectors A brief introduction with emphasis on high energy physics applications

arxiv: v1 [physics.ins-det] 10 May 2011

Detectors for High Energy Physics

Experimental Particle Physics

MTV - S1183 Beam Time Summary. Performance test of MTV new detector : CDC. Yumi Totsuka. Department of Physics, Rikkyo University, Tokyo, Japan

3 Gaseous Detectors. Detectors for Particle Physics Manfred Krammer Institute for High Energy Physics, Vienna, Austria

Detection of X-Rays. Solid state detectors Proportional counters Microcalorimeters Detector characteristics

Status of RAON and LAMPS in Korea

Electronic calibration of the ATLAS LAr calorimeter and commissioning with cosmic muon signals

Transcription:

Spatial resolution of a MPGD TPC using the charge dispersion signal Madhu Dixit Carleton University & TRIUMF Carleton University University of Montreal LAL Orsay CEA Saclay A. Bellerive, K. Boudjemline, R. Carnegie, A. Kochermin, J. Miyamoto, E. Neuheimer, E. Rollin & K. Sachs J.-P. Martin V. Lepeltier P. Colas, A. Giganon & I. Giomataris

MPGD-TPC resolution with charge dispersion ILC TPC challenge: Using ~ 2 mm wide pads, measure ~ 200 points with ~ 100 µm resolution for all tracks (max. TPC drift length ~ 2.5 m). Transverse diffusion sets the ultimate limit on TPC resolution. ILC tracker resolution goal is near the ultimate limit from diffusion for a gaseous TPC. Conventional TPCs with proportional wir/cathode pad endcap readout systems limited by ExB & track angle systematics. A TPC read out with a MPGD endcap could achieve the ILC resolution goal with ~ 2 mm wide pads if the precision of pad charge centroid determination could be improved. Ideas to improve the MPGD TPC resolution: Narrower pads would lead to increased complexity & a larger number of readout channels. Controlled dispersal of track avalanche charge after over a larger area to improve determination of pad centroids with wide pads. M. Dixit ILC Workshop Snowmass 8/23/05 2

Charge dispersion in a MPGD with a resistive anode Modified MPGD anode with a high resistivity film bonded to a readout plane with an insulating spacer. 2-dimensional continuous RC network defined by material properties & geometry. Point charge at r = 0 & t = 0 disperses with time. Time dependent anode charge density sampled by readout pads. Equation for surface charge density function on the 2-dim. continuous RC network: ρ t = 1 2 ρ RC r + 1 ρ ρ(r) 2 r r ρ(r,t) = RC 2t r 2 RC 4t e mm r / mm Q ρ(r,t) integral over pads ns M. Dixit ILC Workshop Snowmass 8/23/05 3

Cosmic ray resolution of a MPGD-TPC 15 cm drift length with GEM or Micromegas readout, B = 0 Ar:CO 2 /90:10 chosen to simulate low transverse diffusion conditions in a high magnetic field. Aleph charge preamps. τ Rise = 40 ns, τ Fall =2 µs. Digitization effectively at 25 MHz by combining 200 MHz FADC time bins. 60 tracking pads (2 x 6 mm 2 ) + 2 trigger pads (24 x 6 mm 2 ). The GEM-TPC resolution was first measured with conventional direct charge TPC readout. The resolution was next measured with a charge dispersion resistive anode readout with a double-gem & with a Micromegas endcap. M. Dixit ILC Workshop Snowmass 8/23/05 4

Resistive anode Micromegas 530 kω/ Carbon loaded Kapton resistive anode was used with GEM. This was replaced with more uniform higher resistivity 1 MΩ/ Cermet for Micromegas. Drift Gap Al-Si Cermet on mylar MESH Amplification Gap 50 µm pillars M. Dixit ILC Workshop Snowmass 8/23/05 5

Simulation - GEM TPC cosmic event with charge dispersion (track Z drift distance ~ 67 mm, Ar/CO 2 90/10 gas) Detailed model simulation including longitudinal & transverse diffusion, gas gain, detector pulse formation, charge dispersion & preamp rise & fall time effects. 2x6 mm 2 pads Simulation Data Centre pad amplitude used for normalization - no other free parameters. M. Dixit ILC Workshop Snowmass 8/23/05 6

The pad response function (PRF) The PRF is a measure of signal size as a function of track position relative to the pad. For charge dispersion non charge collecting pads have signals in contrast to conventional direct charge readout. Unusual highly variable charge dispersion pulse shape; both the rise time & pulse amplitude depend on track position. We use pulse shape information to optimize the PRF. The PRF can, in principle, be determined from simulation. However, system RC nonuniformities & geometrical effects introduce bias in absolute position determination. The position bias can be corrected by calibration. PRF and bias determined empirically using a subset of data which was used for calibration. The remaining data was used for resolution studies. M. Dixit ILC Workshop Snowmass 8/23/05 7

GEM & Micromegas PRFs for TPC track Ar:CO 2 (90:10) 2x6 mm 2 pads The pad response function maximum for longer drift distances is lower due to Z dependent normalization. GEM PRFs Micromegas PRFs Micromegas PRF is narrower due to the use of higher resistivity anode & smaller diffusion after avalanche gain M. Dixit ILC Workshop Snowmass 8/23/05 8

PRFs with the GEM & the Micromegas readout The PRFs are not Gaussian. The PRF depends on track position relative to the pad. PRF = PRF(x,z) PRF can be characterized by its FWHM Γ(z) & base width (z). PRFs determined from the data have been fitted to a functional form consisting of a ratio of two symmetric 4th order polynomials. PRF[x,Γ(z),,a,b] = (1 + a 2x 2 + a 4 x 4 ) (1+ b 2 x 2 + b 4 x 4 ) a 2 a 4 b 2 & b 4 can be written down in terms of Γ and & two scale parameters a & b. M. Dixit ILC Workshop Snowmass 8/23/05 9

Track fit using the the PRF 6 mm 2 mm Track at: x track = x 0 + tan(φ) y row χ 2 = ΣΣ rows i=pads (A i PRF i ) A i [ ] 2 Determine x 0 & φ by minimizing χ 2 for the entire event One parameter fit for x row (track position for a given row) using φ Bias = Mean of residuals (x row -x track ) as a function of x track Resolution = σ of track residuals for tracks with φ < 5 M. Dixit ILC Workshop Snowmass 8/23/05 10

Bias corrections with GEM & with Micromegas Initial bias Initial bias Remaining bias after correction Remaining bias after correction 2 mm pads GEM 2 mm pads Micromegas M. Dixit ILC Workshop Snowmass 8/23/05 11

What is the diffusion limit of resolution for a gaseous TPC? Resolution depends on electron statistics. Electron number N fluctuates from event to event.. σ 2 x = σ 2 0 + C 2 d z σ 0 includes noise & systematic effects. C d = diffusion constant; z = drift distance N eff N eff <N> the average number of electrons = 1/<1/N> the inverse of average of 1/N Gain fluctuations also affect N eff M. Dixit ILC Workshop Snowmass 8/23/05 12

Cosmic ray momentum spectrum Simulation to determine N eff 2 mm x 6 mm pads - Ar/CO 2 90/10 de/dx in Argon Measured pad pulse height distribution Mostly muons at sea level Total Ionization. Statistics of primary ionization & cluster size distribution. de/dx dependence on momentum. Account for track angle & detector acceptance effects. Use simulation to scale measured pulse heights to electron number. N eff = 1/<1/N> determined from pulse height distribution. N eff 38.9 ± 10% (N average = 57) M. Dixit ILC Workshop Snowmass 8/23/05 13

Measured TPC transverse resolution for Ar:CO 2 (90:10) R.K.Carnegie et.al., NIM A538 (2005) 372 R.K.Carnegie et.al., to be published New results σ 2 0 + C 2 D z N e [N eff = 38.9] Compared to conventional readout, resistive readout gives better resolution for the GEM and the Micromegas readout. The z dependence follows the expectations from transverse diffusion & electron statistics. M. Dixit ILC Workshop Snowmass 8/23/05 14

What s next? Beam test at KEK in October 2005 to demonstrate good resolution in a magnetic field using ~ 2 mm wide pads. Two TPCs will be tested in the 1.2 T Jacee magnet. Carleton TPC with a Micromegas with a resistive anode using a new 128 pad PCB designed for tracking in a magnetic field. Ron Settles (MPI ) has designed a TPC to facilitate comparison of different readout options under similar conditions. The MPI-TPC will also be tested at KEK using a resistive anode readout both with GEMs and the Micromegas. M. Dixit ILC Workshop Snowmass 8/23/05 15

A cosmic ray event in the new Carleton 128 pad TPC Relative amplitudes Cosmic track M. Dixit ILC Workshop Snowmass 8/23/05 16

Resolution for cosmic ray tracks for the new 128 pad TPC Ar:CO 2 (90:10) Preliminary Old data (64 pad PCB) X New data - 128 pad TPC The new 128 pad TPC is ready for KEK beam test M. Dixit ILC Workshop Snowmass 8/23/05 17

Summary & outlook Using 2 mm wide pads, we have demonstrated better GEM/Micromegas-TPC resolution with a resistive anode readout than has been achieved with conventional MPGD TPC readout systems. The resolution is near the diffusion limit of resolution for a gaseous TPC. In cosmic tests with no magnetic field, the measured resolution follows the expectations from transverse diffusion & electron statistics. Beam tests in a magnet next to demonstrate good resolution for a TPC in a magnetic field. A resolution of ~ 100 µm for all tracks (2.5 m drift) using ~ 2 mm wide pads appears feasible for the ILC TPC. M. Dixit ILC Workshop Snowmass 8/23/05 18