Thermal modelling for on-interposer thermoelectric sensors

Similar documents
ELECTRO-THERMAL ANALYSIS OF PELTIER COOLING USING FEM

Thermal Sensors and Actuators

Homework Week 3: Nanoscale and macroscale characterization Thermoelectricity: From Atoms to Systems

Supplementary Information for On-chip cooling by superlattice based thin-film thermoelectrics

One dimensional steady state diffusion, with and without source. Effective transfer coefficients

Analysis of the thermal heating of poly-si and a-si photovoltaic cell by means of Fem

2D Simulations and Electro-Thermal Analysis of Micro-Heater Designs Using COMSOL TM for Gas Sensor Applications

NEEDS Thermoelectric Compact Model Documentation Version 1.0.0

Thermoelectric effect

Solar Energy Conversion using Micro Thermoelectric Generator Pheba Cherian, L. Balakumar, S. Joyal Isac

A Simple Method for Thermal Characterization of Low-Melting Temperature Phase Change Materials (PCMs)

/qirt The influence of air humidity on effectiveness of heat sink work. by M. Kopeć*, R. Olbrycht*

Validation of DNS techniques for dynamic combined indoor air and constructions simulations using an experimental scale model

Computer Evaluation of Results by Room Thermal Stability Testing

reported that the available simple contact conductance model was expressed as [5][6]: h sum = h solid + h fluid (1) Where h sum, h solid and h fluid a

OPPA European Social Fund Prague & EU: We invest in your future.

ENSC 388. Assignment #8

Temperature Measurements

MECH 375, Heat Transfer Handout #5: Unsteady Conduction

Simulation and Optimization of an In-plane Thermal Conductivity Measurement Structure for Silicon Nanostructures

3.0 FINITE ELEMENT MODEL

TRANSIENT NUMERICAL ANALYSIS OF INDUCTION HEATING OF GRAPHITE CRUCIBLE AT DIFFERENT FREQUENCY

Example Resistive Heating

Energy Conversion in the Peltier Device

Simulation and Experimental Validation of Induction Heating of MS Tube for Elevated Temperature NDT Application.

Design of an Automated Thermal Cycler for Long-term Phase Change Material Phase Transition Stability Studies

Analytical solutions of heat transfer for laminar flow in rectangular channels

Sensors and Actuators Sensors Physics

Peltier Application Note

Wire Based Flexible Piezoelectric Sensor for Structural Health Monitoring Applications

Thermocouple Calibrations and Heat Transfer Coefficients

Virtual Prototype of a Dielectric Window for High Power Microwave Tubes

Sensing, Computing, Actuating

I. Introduction and Objectives

CHAPTER 7 NUMERICAL MODELLING OF A SPIRAL HEAT EXCHANGER USING CFD TECHNIQUE

Solar Thermoelectric Energy Conversion

International Journal of Research in Advent Technology, Vol.6, No.11, November 2018 E-ISSN: Available online at

Transient Thermal Measurement and Behavior of Integrated Circuits

SIMULATION MODEL OF INDUCTION HEATING IN COMSOL MULTIPHYSICS

MICROMECHANICAL TEMPERATURE SENSOR

Potential use of Thermoelectric Generator Device for Air Conditioning System

Design Of Thermoelectric Generator from Aluminum and Copper Elements

Application of Hot Wire Technique and Comsol Multiphysics in the Heat Transfer Monitoring in Solids.

collisions of electrons. In semiconductor, in certain temperature ranges the conductivity increases rapidly by increasing temperature

Temperature Measurement

OCEAN/ESS 410. Class 3. Understanding Conductive Cooling: A Thought Experiment. Write your answers on the exercise sheet

9th European LS-DYNA Conference 2013

PROBLEM 1.2 ( ) 25 C 15 C dx L 0.30 m Ambient air temperature, T2 (C)

Experimental and theoretical understanding of Forming, SET and RESET operations in Conductive Bridge RAM (CBRAM) for memory stack optimization

Towards a Quantitative Prediction of Ice Forming at the Surface of Airport Runways

arxiv: v1 [physics.app-ph] 25 Mar 2018

Inverse Heat Flux Evaluation using Conjugate Gradient Methods from Infrared Imaging

Thermal Management for LED Applications

Multiphysics Simulation and Optimization for Thermal Management of Electronics Systems

BETTER DESIGN AND NEW TECHNOLOGIES IMPROVE LASER POWER MEASUREMENT INSTRUMENTATION

Multiphysics Modeling

Finite-Element Evaluation of Thermal Response Tests Performed on U-Tube Borehole Heat Exchangers

Heat Removal of a Protection Chip after Surge Pulse Tom Graf Hochschule Luzern T&A Technikumstrasse 21 CH-6048 Horw Switzerland

Figure (13-1) Single Thermoelectric Couple where Th > Tc

Ion Concentration and Electromechanical Actuation Simulations of Ionic Polymer-Metal Composites

ELECTRICAL AND THERMAL DESIGN OF UMBILICAL CABLE

Available online at ScienceDirect. Energy Procedia 75 (2015 ) Multiphysics Simulations of a Thermoelectric Generator

Modelling of temperature profiles in Nd:YAG laser annealed GaAs/AlGaAs quantum well microstructures

SENSORS and TRANSDUCERS

Modeling Internal Heating of Optoelectronic Devices Using COMSOL

Jorge García-Cañadas

Thermo-Fluid Dynamics of Flue Gas in Heat Accumulation Stoves: Study Cases

Sensibility Analysis of Inductance Involving an E-core Magnetic Circuit for Non Homogeneous Material

에너지하베스팅의핵심이되는열전소자측정기술 텍트로닉스김수길부장

TEMPERATURE DISTRIBUTION OF AN INFINITE SLAB UNDER POINT HEAT SOURCE

Temperature Measurement

TXL L. Thermoelectric Generator Module with lower internal resistance and 127 Thermoelectric Couples. Internal Resistance: Rint = 4.

MODELING OF JOULE HEATING AND THERMOELECTRIC TRANSPORT IN THIN FILM SILICON FOR SJEM MEASUREMENT YOUNGJOON KOH THESIS

Simulation of the Temperature Profile During Welding with COMSOL Multiphysics Software Using Rosenthal s Approach

True/False. Circle the correct answer. (1pt each, 7pts total) 3. Radiation doesn t occur in materials that are transparent such as gases.

Section 7. Temperature Measurement

3D ELECTROMAGNETIC FIELD SIMULATION OF SILICON CARBIDE AND GRAPHITE PLATE IN MICROWAVE OVEN

Modelling, Simulation and Temperature Effect Analysis of Mutual Induction based High Temperature Level Sensor using COMSOL Multiphysics

CFD AND CONJUGATE HEAT TRANSFER ANALYSIS OF HEAT SINKS WITH DIFFERENT FIN GEOMETRIES SUBJECTED TO FORCED CONVECTION USED IN ELECTRONICS COOLING

ABSTRACT. Localized thermoelectric self cooling in semiconductor materials is among the

Mathematical Investigation and CFD Simulation of Monolith Reactors: Catalytic Combustion of Methane

Electrons are shared in covalent bonds between atoms of Si. A bound electron has the lowest energy state.

Modeling thermal conductivity: a Green-Kubo approach

Comparative assessment of a temperature distribution into different CPU coolers

Supplementary Figure 1. Characterization of the effectiveness of ion transport in CNT aerogel sheets. (a)

Chapter 1 Overview of Semiconductor Materials and Physics

Numerical modeling of magnetic induction and heating in injection molding tools

PROBLEM 1.3. dt T1 T dx L 0.30 m

Simulation of Free Convection with Conjugate Heat Transfer

Complex superlattice unit cell designs for reduced thermal conductivity. Abstract

Hydrodynamic heat transport regime in bismuth: a theoretical viewpoint

Modelling Dynamical Fluorescent Micro Thermal Imaging of the Heat Diffusion in the La 5 Ca 9 Cu 24 O 41 Spin Ladder Compound.

3. Consider a semiconductor. The concentration of electrons, n, in the conduction band is given by

Control and Mechatronics Engineering Department, Universiti Teknologi Malaysia, UTM Johor Bahru, Johor, Malaysia

CB FDHMT. Contract No GSI Helmholzzentrum für Schwerionenforschung GmbH Planckstraße Darmstadt. 15. December /11

Thermal Field in a NMR Cryostat. Annunziata D Orazio Agostini Chiara Simone Fiacco

4.2 Molecular orbitals and atomic orbitals Consider a linear chain of four identical atoms representing a hypothetical molecule.

Electro-Thermal Transport in Silicon and Carbon Nanotube Devices E. Pop, D. Mann, J. Rowlette, K. Goodson and H. Dai

Low frequency impedance spectroscopy analysis of thermoelectric modules

Thermal Systems. What and How? Physical Mechanisms and Rate Equations Conservation of Energy Requirement Control Volume Surface Energy Balance

Transcription:

Thermal modelling for on-interposer thermoelectric sensors C. Morel 1,2 and G. Savelli 1,2 1 Univ. Grenoble Alpes, F-38000 Grenoble, France 2 CEA, Liten, Nanomaterials Technologies Department, F-38000 Grenoble, France Introduction This paper presents a study about micro ThemoElectric-Sensors (µtes). These µtes are used to detect hot temperature spots in microelectronic devices, allowing to deliver a global thermal map identifying areas to cool. µtes are based on the Seebeck effect which converts thermal flow to electrical signals. Two thermoelectric (TE) materials have been tested in this study, namely polycrystalline SiGe (Silicium-Germanium alloy) and silicide-based Quantum Dot Super Lattices (QDSL). Our objective is to obtain a high µtes sensitivity (around 100 mv/k) with a low response time. Experimental Set-up Several µtes have been processed around a 5.2x5.8 mm² hot source dissipating a 3 W thermal power. Each µtes is made of several p-n junctions connected electrically in series and thermally in parallel. The p and n lines are characterized by positive S p and negative S n Seebeck coefficients, respectively, corresponding to a global Seebeck coefficient equal to: S np = S S (1) p n The sensitivity Se of a µtes is defined by the following equation: V = Snp (2) T oc Se = N where N is the number of junctions and V oc the opencircuit voltage generated by the temperature difference T. Here, the temperature and electric potential fields are determined by numerical calculations then the µtes sensitivity for each particular geometry is calculated. Thermoelectric Governing Equations The equations solved are the ones for the temperature T and the electric potential U [1]. The temperature equations are: T ρc +.q = Q t q = k T + STJ Q = J.E E = U (3) where ρ denotes the material density, C the specific heat capacity and k the thermal conductivity. The heat flux density q is split in two contributions: the usual heat transfer proportional to the temperature gradient (Fourier s law) and an additional contribution due to the Seebeck effect where S is the Seebeck coefficient (measured in µv/k) and J is the electric current density (in A/m 2 ) given by the following equation: ( U + S T) J = σ (4) where σ is the electrical conductivity (measured in S/m). In Eqs. (3), the other relevant quantities are the electric field E and the Joule heat source Q. According to Jaegle [2] the equation for the electric potential U is: 2 2 2 U U U + + =.J x t y t z t ε (5) where ε is the material permittivity. Geometrical model A typical µtes involves several hundred junctions, but in order to keep manageable simulations, we will only reproduce the behavior of five junctions and extrapolate the obtained sensitivity to the number of junctions of the real system. We can also reproduce several micro-channels (containing air or circulating water) under the thin layer of the simulated portion of the µtes. The simulated system is illustrated on the Figures 1-6. 1

Figure 1: Bottom view of the system showing the six µchannels. Figure 5: possible exchange with water (where the channel walls are colored in blue). Figure 2: Top view showing the p-type TE lines in blue. Figure 3: Zoom showing the metallic electrical connections between the p and n lines (in blue on the figure). Figure 6: Ground is located at one extremity of the µtes (in blue). A thin layer containing ten lines p and n connected electrically by small silicides are placed on a wafer of silicium oxide pierced by several rectangular channels (or not pierced). A thermal boundary condition (BC) is imposed on an aluminum part showed in figure 4. This BC can be a Dirichlet BC (the temperature is imposed equal to 120 C which is the maximum admissible temperature) or a Neumann BC (the heat flux density is imposed). If the Neumann BC is chosen, the heat flux density is calculated from the TTC characteristics: q = P/S = 3W/(5.8*5.2 mm 2 ) = 99469 W/m 2. Material properties The material properties measured from poly-sige and QDSL at room temperature are given in Table 1. Figure 4: Hot source in blue (µchannels are also clearly visible on this figure). Table 1: TE material properties. property SiGe SiGe QDSL QDSL Line type p n p n r = 1/σ 3.10-5 3,4.10-5 1,6.10-4 2,5.10-4 S (µv/k) 142-185 253-267 k (W/mK) 4.7 4.1 5.3 6.3 ρ (kg/m 3 ) 2330 2330 2330 2330 C (J/kgK) 710 710 710 710 2

According to Eq. (2), the number of junctions N must be at least 306 for poly-sige and 193 for QDSL to obtain a sensitivity Se equal to 100 mv/k. Table 2 summarizes the geometrical parameters retained for the complete µtes. Table 2: Geometrical parameters. Parameters Values Line length 500 µm Line thickness 2 µm N 315 Line width 5 µm Line spacing 3 µm Total width 5.04 mm Figure 8: Potential field at t = 10 s. This thermal equilibrium is quickly obtained and Figures 9-10 show the time evolution of the µtes temperatures at the hot and cold sides and the output voltage for the first 0.5 s. Results with Dirichlet BC Following results are obtained with poly-sige material, in a configuration without µchannels and a temperature equal to 120 C at the Dirichlet BC for the hot source. Figure 7 shows that the temperature obtained in the whole domain at time = 10 s is near 120 C and Figure 8 shows the surface electric potential field which gives a voltage equal to 0.9 mv. Figure 9: Temporal evolution of the hot and cold sides temperatures. Figures 10 and 12 show that a voltage peak is achieved at the beginning of the simulation. Figures 9-10 for poly-sige show that this peak is equal to 70 mv and the corresponding temperature difference between the hot and cold sides is approximately equal to 43 C. Using Eq. (2), a sensitivity Se equal to 1.63 mv/ C is found for only 5 junctions. Therefore, the resulting sensitivity for a µtes having 315 junctions would be 103 mv/ C which is above the required 100 mv/ C. Figure 7: Temperature field at t = 10 s. Figure 10: Temporal evolution of the output voltage. Figures 11-12 present the same results obtained from the QDSL material. 3

Figure 11: Hot and cold sides temperatures with QDSL. Figure 13: Temperature increase on the hot and cold sides of the µtes. Nevertheless, if a zoom on the beginning of the calculation is made, we can see that a temperature difference between the hot and cold sides appears quickly, and then remains constant (see Figure 14). Figure 12: Output voltage with QDSL. As shown in these figures, the temperature difference did not changed (43 C) but the voltage peak is now equal to 112 mv. Therefore, we find a sensitivity equal to 2.6 mv/ C for 5 junctions, corresponding to 164 mv/ C for 315 junctions. A QDSL-based µtes has a higher sensitivity than a poly-sige-based µtes due to higher Seebeck coefficient for QDSL (see Table 1). Figure 14: Zoom of the temperatures at the beginning of the calculation. The output voltage also increases rapidly at the beginning and then remains approximately constant, as shown in Figure 15. Results with Neumann BC Here the Dirichlet BC on the temperature is replaced by a Neumann BC, with a heat flux density equal to 99469 W/m 2. In this case, the increase of temperatures on the two sides of the µtes is quite slow (see Figure 13). Figure 15: Output voltage with poly-sige. Figure 16 represents the corresponding result obtained for QDSL material. 4

Figure 16: Output voltage with QDSL. Here again, the voltage peak is reached very quickly, i.e. in the first milliseconds. The peak value is 0.12 mv for poly-sige and 0.19 mv for QDSL, with a temperature difference equal to 0.072 C. This gives a sensitivity Se = 1.66 mv/ C for poly-sige and 2.64 mv/ C for QDSL in the case of 5 junctions. For the real case of 315 junctions, we obtain Se = 105 mv/ C for poly-sige and 166 mv/ C for QDSL, still greater than the 100 mv/ C required. Figure 18: Temporal evolution of the hot and cold sides temperatures with micro-channels. The effect of the micro-channels is clearly visible in this figure since the cold side remains at the initial temperature of 20 C, giving a final temperature difference around 25 C. Effect of the channels In this section, µtes and micro-channels technologies are combined (see Figures 1-5). The goal is to increase the temperature difference between the two sides of the sensor. These µchannels are filled with air (exchanged coefficient equal to 15 W/m 2 / C) and the last one (the nearest from the µtes cold side) with flowing water (exchange coefficient equal to 10000 W/m 2 / C). Figure 17 shows a temperature field at time t = 10 s obtained with six channels and poly-sige lines. The temperature BC for this calculation is the imposed heat flux. Figure 19: Time evolution of the output voltage. The absolute value of the output voltage attains 41 mv at the end of calculation (t = 10 s), corresponding to a sensitivity of 103 mv/ C for 315 junctions. Conclusions In this paper, the influence of µtes geometry and TE materials has been studied thanks to COMSOL Multiphysics software. Our objective was to obtain a µtes sensitivity greater than 100 mv/ C with a fast response time. This objective has been achieved for the two types of material: poly-sige and QDSL, and it has been shown that the QDSL has a 60% higher sensitivity than poly-sige material. Figure 17: Temperature field with micro-channels. Figures 18 and 19 give the two sides temperature evolution and the output voltage evolution for this calculation. Acknowledgements The research leading to these results has been performed within the STREAMS project (www.project-streams.eu) and received funding from 5

the European Community's Horizon 2020 program under Grant Agreement n 688564. References [1] Heat Transfer Module User s Guide, COMSOL V5.2, 2015. [2] M. Jaegle, Simulating Thermoelectric Effects with Finite Element Analysis using COMSOL, Proceedings ECT, Odessa, p. 222, (2007). 6

7