Real-Time High Resolution X-Ray Microscopy (XM)

Similar documents
Thermal Management of SMT LED Application Note

Failure Analysis Report

This is the summary of changes to MIL-STD-883 for Revision H February 28, 2010

TRENDS IN LEVENSDUURTESTEN VOOR MICRO-ELEKTRONICA PLOT CONFERENTIE

ASTM E545 TUTORIAL ON PROPER IMAGE QUALITY INDICATOR USAGE

Electrical Conductive Adhesives with Nanotechnologies

Technical Notes. Introduction. PCB (printed circuit board) Design. Issue 1 January 2010

1 INTRODUCTION 2 SAMPLE PREPARATIONS

Electron probe microanalysis - Electron microprobe analysis EPMA (EMPA) What s EPMA all about? What can you learn?

Physics 30 Modern Physics Unit: Atomic Basics

Chemistry 101 Chapter 11 Modern Atomic Theory

Cambridge International Examinations Cambridge Ordinary Level

Production of X-rays. Radiation Safety Training for Analytical X-Ray Devices Module 9

Nordson MARCH Concord, CA, USA

Part Qualification/Upscreen:

Reliability Analysis of Moog Ultrasonic Air Bubble Detectors

Unit 2 - Electrons and Periodic Behavior

BALL GRID ARRAY REWORK TRAINING CERTIFICATION TEST (DVD-96C) v.2

Geometric Considerations in the

Designation: NWI DIF Horizontal Hail impact Standard

TECHNICAL INFORMATION

MEMS Metrology. Prof. Tianhong Cui ME 8254

GCSE PHYSICS REVISION LIST

Name Final Exam May 1, 2017

Assessment of Soft Errors due to Alpha Emissions from Presolder on Flip Chip Devices Rick Wong, Shi-Jie Wen, Peng Su, Li Li 10/30/09

The Increasing Importance of the Thermal Management for Modern Electronic Packages B. Psota 1, I. Szendiuch 1

March 26, Title: TEMPO 21 Report. Prepared for: Sviazinvest, OJSC. Prepared by: Cree Durham Technology Center (DTC) Ticket Number: T

ASTRONOMY. Chapter 5 RADIATION AND SPECTRA PowerPoint Image Slideshow

TANDEX TEST LABS, INC Business Ctr. Dr. Irwindale CA Phone : Fax :

X-RAY SCATTERING AND MOSELEY S LAW. OBJECTIVE: To investigate Moseley s law using X-ray absorption and to observe X- ray scattering.

S-S35B-F

Reliability Study of Subsea Electronic Systems Subjected to Accelerated Thermal Cycle Ageing

PHYS General Physics II Lab The Balmer Series for Hydrogen Source. c = speed of light = 3 x 10 8 m/s

HOW TO APPROACH SCANNING ELECTRON MICROSCOPY AND ENERGY DISPERSIVE SPECTROSCOPY ANALYSIS. SCSAM Short Course Amir Avishai

INDUSTRIAL RADIOGRAPHY

INAYA MEDICAL COLLEGE (IMC) RAD LECTURE 1 RADIATION PHYSICS DR. MOHAMMED MOSTAFA EMAM

Dynamic behaviour of electronics package and impact reliability of BGA solder joints

progressive electromagnetic wave

Lecture 1: Applications of High Power Electromagnetic Systems

INAYA MEDICAL COLLEGE (IMC) RAD LECTURE 1 RADIATION PHYSICS DR. MOHAMMED MOSTAFA EMAM

Brighter and Cooler. Luna 160. Best Lumen / Watt LED Flip Chip COB Module

Reliability Evaluation Method for Electronic Device BGA Package Considering the Interaction Between Design Factors

charge. Gamma particles turned out to be electromagnetic radiation, the same as light, but with much higher energy.

Electro - Principles I

An Introduction to: Light

Temperature Measurement

Brighter and Cooler. 95CRI Luna 200. Best Lumen / Watt LED Flip Chip COB Module

MIL-STD-883G METHOD DIE SHEAR STRENGTH

Enhanced Transmission by Periodic Hole. Arrays in Metal Films

In Situ Ultrasonic NDT of Fracture and Fatigue in Composites

In Situ X-Ray Emission Spectroscopy of Battery Materials

[ ] Sensors for Temperature Measurement, and Their Application 2L R 1 1 T 1 T 2

WM 07 Conference, February 25 March 01, 2007, Tucson, AZ

Bending Load & Calibration Module

A Quality Test Plan for Pb-Free Products. By Keith M. Sellers Managing Scientist NTS Baltimore

Specification for Embedded Passive Device Capacitor Materials for Rigid and Multilayer Printed Boards

Optical Systems Program of Studies Version 1.0 April 2012

DATA SHEET SURFACE-MOUNT CERAMIC MULTILAYER CAPACITORS C-Array: Class 2, X7R 16/25/50 V size 0612 (4 0603) Product Specification Jul 21, 2003 V.

LM34 Precision Fahrenheit Temperature Sensors

Next-Generation Packaging Technology for Space FPGAs

Physics For Scientists and Engineers A Strategic Approach 3 rd Edition, AP Edition, 2013 Knight

Because the third wire carries practically no current (due to the voltmeter's extremely high internal resistance), its resistance will not drop any

Activity 11 Solutions: Ionizing Radiation II

L 35 Modern Physics [1]

Delamination Modeling for Power Packages and Modules. Rainer Dudek, R. Döring, S. Rzepka Fraunhofer ENAS, Micro Materials Center Chemnitz

Full Color SMT Chip LED (3.5 x 3.0 x 1.4 mm)

hν' Φ e - Gamma spectroscopy - Prelab questions 1. What characteristics distinguish x-rays from gamma rays? Is either more intrinsically dangerous?

Electroscope Used to are transferred to the and Foil becomes and

RS INDUSTRY LIMITED. RS Chip Array ESD Suppressor APPROVAL SHEET. Customer Information. Part No. : Model No. : COMPANY PURCHASE R&D

UVTOP265-HL-TO39. Description. Maximum Rating (T CASE = 25 C) Electro-Optical Characteristics (T CASE = 25 C, I F = 20 ma)

Reference literature. (See: CHEM 2470 notes, Module 8 Textbook 6th ed., Chapters )

CTAB-Influenced Electrochemical Dissolution of Silver Dendrites

Planetary Science: Investigations 9-10 I-Check Quiz STUDY GUIDE Name HR Date

LM35 Precision Centigrade Temperature Sensors

THE ECONOMICS OF DIE ATTACH VOIDING IN LED ASSEMBLIES

PH213 Chapter 24 Solutions

[2] (b) An electron is accelerated from rest through a potential difference of 300 V.

X-ray Interaction with Matter

29:006 FINAL EXAM FRIDAY MAY 11 3:00 5:00 PM IN LR1 VAN

Reliability analysis of different structure parameters of PCBA under drop impact

Chapter 6 Electronic Structure of Atoms

MLCC APPLICATION GUIDE

Matter mass space atoms solid, a liquid, a gas, or plasm elements compounds mixtures atoms Compounds chemically combined Mixtures not chemically

Simulation of the Influence of Manufacturing Quality on Thermomechanical Stress of Microvias

Applications of Terahertz Radiation (T-ray) Yao-Chang Lee, National Synchrotron Research Radiation Center

Scattering Lecture. February 24, 2014

How Does a Microcantilever Work?

CHAPTER 6 THERMAL DESIGN CONSIDERATIONS. page. Introduction 6-2. Thermal resistance 6-2. Junction temperature 6-2. Factors affecting R th(j-a) 6-2

Gauss/Tesla meter Model 8000 Series

Product Data Sheet PD-0053-A

WINTER 2015 EXAMINATION Subject Code: Model Answer (Applied Science- Physics) Page No: 01/12 Que. No.

Chapter 37 Early Quantum Theory and Models of the Atom. Copyright 2009 Pearson Education, Inc.

Study of Solder Ball Bump Bonded Hybrid Silicon Pixel Detectors at DESY

Component & Board Level Cooling.

Qualification Test Report

Robustness of Surface Mount Multilayer Ceramic Capacitors Assembled with Pb-Free Solder

Part 12- Physics Paper 1 Atomic Structure Application Questions Triple Science

CLCC Solder Joint Life Prediction under Complex Temperature Cycling Loading

LITE-ON TECHNOLOGY CORPORATION

Microsemi Power Modules. Reliability tests for Automotive application

Transcription:

The Information You Need...When You Need It. Real-Time High Resolution X-Ray Microscopy (XM) Through high-resolution X-ray microscopy, we are able to non-destructively examine the internal structure of samples in real-time, at magnifications up to 1000X. While the internal mechanisms of these samples are usually not visible under other means, XM offers us a tool to watch them in operation. Unlike static radiography systems, XM allows the sample under examination to be positioned in a direction that permits the best view of a feature of interest. The sample is able to be move in the X, Y and Z directions and can also be tilted and rotated. When images are calibrated, radiopacity (ASTM F640) and linear measurements can be made. Video recordings of switches, relays, and other mechanical or electromechanical devices can be made to understand their inner workings or perform failure analysis. How it Works: We begin by generating X-rays by impinging a beam of electrons onto a metal target. The energy of an impinging electron is transferred to the orbital electrons of the atoms of the target. Photons are emitted when the excited electrons jump to a lower energy level. These photons have a frequency which places them into the range of electromagnetic radiation which we call X-rays. The energy of these X-rays is directly related to the energy of impinging electrons and the target material. X-rays have the ability of penetrating solid objects; the density of the object determines how many electrons penetrate the detector. Geometric magnification is made possible by adjusting the distance between the source of the X-rays, the sample being irradiated and the detector. The closer

the sample is to the source and the further it is from the detector, the larger the image will be on the detector. XM Applications Include: Materials Evaluation Dispersion of fillers polymers Delamination in thin films Real-time evaluation of electrical and thermal devices Real-time evaluation of micro-surgical implements Failure Analysis Opens/shorts in bond wires Bond wire placement Loose or Extraneous components in packages Quality Control Ball Grid Array (BGA) voiding in solder balls Voids or cracks in welds Die attach voiding Linear measurements Construction details Deformed internal components Micro-fracture detection in materials Inspection of medical products while in sterile packaging Clearance between embedded wires Data Presentation: We can present data either as an image on a computer monitor or as an electronic image on CD. The system is capable of recording videos of the sample under examination to allow further viewing of how the components work together. These videos are recorded in the.mpg format. Sample Constraints: The necessary sample size is usually determined by the amount of translation needed and type of examination. The maximum sample size is approximately 14 by 15 inches

(although larger may be possible in specific instances) and the sample can weigh no more than 10 pounds.

Examples of Data: Angle view of printed circuit board with surface mount components. Note small, spherical solder balls loose inside the sample (center of view), which can possibly lead to electrical shorts if loose inside the package. Inspection of pharmaceutical tablets for damage during manufacturing, while still sealed in their sterile foil pouches.

Failed conductor in a household appliance. Note the melting of the individual conductors caused by arcing (near the tip of the white arrow).