PRODUCT CATALOGUE PREssURE switch

Similar documents
DS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

DS 200 DS 200 DRUCK & TEMPERATUR LEITENBERGER GMBH. Electronic Pressure Switch. Stainless Steel Sensor. Electronic Pressure Switch

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.

ED 701 General Industry Pressure Transmitter

Pressure transmitters for industrial applications MBS 32 and MBS 33

Pressure Transmitter ED 701

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27

Industrial Pressure Transmitter

Industrial Pressure Transmitter

Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level

Field IT 50T Series Transmitters

Operating Instructions for Digital Manometer. Model: MAN-SD

Hydraulic Pressure NAH Applications. Features. New generation available - refer to

TF 202 / TF 202-Ex. Field mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

Relative pressure transmitter type 520

TF 212 / TF 212-Ex. Field mounted temperature transmitters, PROFIBUS PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels 10/11-8.

THM80X Series Feature Application. Temperature & Humidity / Flow Measuring Specialist

BTE5000 / PTE5000 / PTU5000 Series Precision differential pressure transmitters

Pressure Measurement Single-range transmitters for general applications

S95.3U01 / S95.3U11. Head mounted temperature transmitters, programmable, Pt 100 (RTD), thermocouples, electrical isolation

v = m / s Thermal Flow Sensors TA with thin-film sensor element Probes Probe Guides Measuring Tubes

Installation guide 862 MIT / MIR

ISEmax CAM40/CAS40. Technical Information

SINEAX VK 636 Programmable Temperature Transmitter with PROFIBUS-PA protocol

ATEX/IECEx RTD temperature probe

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas

4.2. Ex-Ceiling light fittings AB 80 / AB 05 LED / AB 05 / AB 12 NAV 70. (Zone 1, 2, 21, 22)

Fitting PS P - B - R2

S95.3U02 / S95.3U12. Head mounted temperature transmitters, HART programmable, Pt 100 (RTD), thermocouples, electrical isolation

RoHS. Versatile. X g. X 2 e

v = 00,20 m/s Thermal Flow Sensors TA with thin-film sensor element Probes Probe guides Measuring tubes

Field mounted Temperature Transmitter TF212/TF212-Ex

SINEAX VK 626 Programmable Temperature Transmitter for RTD and TC inputs, with HART protocol

Direct-operated 2/2-way compact solenoid valves Type EV210A

Operating instructions Pressure sensor PN / / 2007

Reflex-Radar BM 100 A

DRS 61: Incremental encoders, number of lines and zero pulse width freely programmable DRS 60: Incremental Encoders with Zero-Pulse-Teach

Direct-operated 2/2-way solenoid valves Type EV210B

Pressure. 1 Fitting PA R - N R2

D5.2 Type. Draw wire mechanics with incremental encoder. Measuring length max. 2 m. Compact and simple. Order code draw wire encoder

all stainless steel transducer multimedia compatibility


TF 212 / TF 212-Ex. Field mounted temperature transmitter, Profibus PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels. ABB Instrumentation

Solenoid valves 2/2-way direct-operated type EV210A

TSK. Flap-Type Flowmeter. Range: to GPM Accuracy: ± 2.5% of Full Scale P max. : 580 PSI T max

AIR PREPARATION. ELECTRONICALLY CONTROLLED PRESSURE REGULATING VALVE (PROPORTIONAL PRESSURE REGULATING VALVE) SERIES control

CALYS 80P. Field pressure calibrator with high accuracy 0.01%

T20WN. Data Sheet. Torque transducers. Special features. Installation example with bellows couplings. B en

PHOENIX CONTACT - 04/2016. Features

Single point load cells

4/4-way servo solenoid directional control valves, directly operated, with electrical position feedback and on-board electronics (OBE)

Level Sensor PanCake PR 6251 and Mounting Kit PR 6051

Conductivity sensor for hygienic applications

Z7A. Load cells. Special features. Data sheet. Wiring code

Linear measuring technology

W 9 L: Laser photoelectric switches: small, light and reliable

Absolute encoders multiturn

Exchangeable measuring insets SensyTemp TSA101

Sensors for pressure control OsiSense XMLR

Page 1 of 16 Issue No. 0 of IECEx TUN X

4.13. Ex-Floodlights of the series FMV LED / NSSFMV. (Zone 2, 22) service life and a high level of efficiency. NFMV floodlights for highpressure

DVZ. Vortex Flowmeter Compact. for low viscosity liquids. Range: l/min. Accuracy: ±2.5% of full scale. p max : 20 bar; t max : 80 C

I Ex d/e Switch- and Control-Equipment I

Gear Wheel Flowmeter for viscous liquids Model DZR. (option 3):

Model DS1200-AMT-Ex Intrinsically Safe 4-20mA ATEX Certified Dewpoint Hygrometer Ranges available between -120 C to +20 C (-166 F to +68 F) dewpoint

W 34: Sensor technology that does justice to demanding requirements

Ex floating switches and Ex immersion probes

Dimensional drawing face mount flange radial. R = bending radius min. 40 mm. Dimensional drawing face mount flange axial

BTEL5000 / PTUL5000 Series Precision very low differential pressure transmitters

Physikalisch-Technische Bundesanstalt

Its modular concept allows to build up a ball valve for any degree of automation and any kind of application

TABLE OF CONTENT. ATEX Certificate. Designation code. Circuit diagrams. Sensors. Sensors. Explosion-proof sensors from Pulsotronic

EX-EMERGENCY LIGHT FITTINGS

Compact and low-cost monitoring of conductive liquids. Magnetic-inductive flow metering from ifm.

TH 202 / TH 202-Ex. Field mounted temperature transmitter, HART programmable, Pt 100 (RTD), thermocouples, electrical isolation. ABB Instrumentation

FLOW SENSOR FOR LIQUID MEDIA Serie 210

CALYS 120 IS. ATEX documenting multifunction calibrator with high accuracy 0.006%

4.3. Ex-Pendant light fittings AB 50 / SPG 1N / AB 51 / EVI 200 / EVI 500 / EV35 LED. (Zone 1, 2, 21, 22)

MIK. Electromagnetic Flowmeter Compact. for conductivity liquids. Range from liquids, acids and caustic solutions:

Capacitance Level Measurement Electronic Inserts EC 37 Z, EC 47 Z

Ex-Floodlights of the series FMV LED / NFMV / NSSFMV. Stainless steel NSSFMV floodlights for particularly. in harsh environments

Full Metal Variable Area Flow Meter and Counter

Thermal Mass Flow Meter for Gases

SITRANS F flowmeters. SITRANS F US System information SITRANS F US Ultrasonic flowmeters 4/181

Flow Measurement. SITRANS F M System information SITRANS F M electromagnetic flowmeters. 4/22 Siemens FI

Ring-Torsion Load Cells RTB

Certificate No.: IECEx BVS , issue 3 Annex Page 1 of 9

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

Explosion-protected recessed ceiling LED-light and fluorescent light fittings

Thermal-Magnetic Circuit Breaker 2210-S2...

Thermal-Magnetic Circuit Breaker 2210-S2...

I nllk 08018/18 I nllk I nllk 08036/36 I nllk I I nllk 08058/58 I

Operating instructions Magnetic-inductive flow meter SM6x04 SM7x04 SM8x04

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:

Air velocity & IAQ measuring instruments

ANNEX to IECEx Certificate

Transcription:

PRODUCT CATALOGUE PREssURE switch w w w. p a a b. c o m

Pressure AT THe HIGHesT LeVeL Successful mediumsized companies are not successful because they are active in many areas, but rather because they concentrate on one area and do it better than anyone else This is our philosophy. That s why BDSENSORS has concentrated on electronic pressure measurement technology from the beginning. With our unremitting product and and quality strategy we have been successful in becoming a major player on the world market for electronic pressure sensing devices within a few years.

with 60 employees at locations in Germany, the czech republic, russia and china BD sensors has solutions from 0. mbar to 6000 bar: > pressure sensors, pressure transducers pressure transmitters > electronic pressure switches > pressure measuring devices with display and switching outputs > hydrostatic level probes INDeX Pressure switch with DIsPLAy 9 INDusTry OeM 9 Pressure switch without DIsPLAy 606 Two pressure transmitters and a submersible probe, based on a stainless steel silicon sensor were the beginning. Today the range extends to more than 70 standard products, from economical OeM devices to highend products with HArT communication or field bus interface. ArGuMeNTs 66 In addition we have developed hundreds of specific applications, underlining the competence and flexibility of BD sensors. The excellent price/performance ratio of our products is proof of the fact that we are able to meet the toughest demand: Being a problemsolver for our s. For large production batches as well as for small production numbers, no matter for what medium or external factors, with almost any mechanical or electrical connection we solve your problem flexibly, quickly and costefficiently. www.bdsensors.com

MATrIX display housing contacts pressure port stainless steel ball housing plastic accuracy (FSO) / / / nominal pressure [bar] inch and NPT thraed inch thread flush dairy pipe clamp certificates page with display DS 00 0. % 0 00 up to 0 600 EX 9 DS 0 0. % 0 0. up to 0 600 EX 0 DS 00 0. % 0 0. up to 0 600 EX 9 DS 0 0. % 0 0. up to 0 600 EX 0 DS 0 0. % 0 6 up to 0 600 EX 9 DS 0 0. % 0 0.0 up to 0 EX 0 DS 0. % 0 600 up to 0 00 EX 8 DS 00P 0. % 0 0. up to 0 0 EX, A 9 DS 00P 0. % 0 60 up to 0 00 EX, A 8 DS 0P 0. % 0 0. up to 0 0 EX 9 DS 7 0. % 0 6 up to 0 600 6 DS 0. % 0 up to 0 00 79 without display DS % 0 up to 0 0 606 DS 6 % 0 up to 0 00 66 according to IEC 60770

Pressure switch with DIsPLAy DS 00 Intelligent Electronic Pressure Switch Stainless Steel Stainless Steel Sensor accuracy according to IEC 60770: standard: 0. % FSO option: 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 600 bar Contacts or independent PNP contacts, freely configurable Analogue output wire:... 0 ma wire: 0 ma / 0 0 V others on request Special characteristics The electronic pressure switch DS 00 is the successful combination of intelligent pressure switch digital display and has been specially designed for numerous applications in various industrial sectors. As standard the DS 00 offers a PNP contact and a display module, which is mounted rotable in the ball housing. Additional optional versions like e.g. an intrinsically safe version, a second contact and an analogue output complete the profile. Preferred areas of use are indication of measured values on a digit LED display rotatable and configurable display module Plant and Machine Engineering Heating and Air Conditioning Optional versions ISversion Ex ia = intrinsically safe for gases Environmental Engineering (water sewage recycling) pressure sensor welded specific versions

6 DS 00 Input pressure range Nominal pressure gauge / abs. [bar] 0 0.0 0.6 0. 0.0 0.60.6. 6 Overpressure [bar] 0. 0 0 0 0 Burst pressure [bar] 7.... 7. 7. 0 Nominal pressure gauge / abs. [bar] 0 6 0 60 00 60 0 00 600 Overpressure [bar] 0 80 80 0 0 0 600 000 000 000 Burst pressure [bar] 0 0 0 0 0 0 000 0 0 0 Vacuum resistance P N bar: unlimited vacuum resistance P N < bar: on request Contact Number, type standard: PNP contact option: independent PNP contacts Max. switching current... 0 ma / and wire: contact rating ma, shortcircuit resistant; V switch = V S V 0... 0 V / wire: contact rating 00 ma, shortcircuit resistant Accuracy of contacts ± 0. % FSO Repeatability 0. % FSO Switching frequency wire: max. 0 Hz / wire: 0 Hz Switching cycles > 00 x 0 6 Delay time 0... 00 sec with ISprotection max. contact possible Analogue output (optionally) / Supply wire current signal... 0 ma / V S =... 6 V DC permissible load: R max = [(V S V S min) / 0.0 A] response time: < 0 msec wire current signal with ISprotection... 0 ma / V S =... 8 V DC permissible load: R max = [(V S V S min) / 0.0 A] response time: < 0 msec wire current signal... 0 ma / V S = V DC ± 0 % adjustable (turndown of span :) permissible load: R max = 00 response time: < 0 msec wire voltage signal 0 0 V / V S = V DC ± 0 % adjustable (turndown of span :) permissible load: R min = 0 k response time: < 0 msec Without analogue output V S =... 6 V DC Accuracy standard: nominal pressure < 0, bar: ± 0, % FSO nominal pressure 0, bar: ± 0, % FSO option: nominal pressure 0, bar: ± 0, % FSO accuracy according to IEC 60770 limit point adjustment (nonlinearity, hysteresis, repeatability) with turndown of span the analogue signal is adjusted automatically to the new measuring range Thermal effects (Offset and Span) Nominal pressure P N [bar] 0 < 0.0 0.0 Tolerance band [% FSO] ± 0.7 ± ± 0.7 in compensated range [ C] 0... 8 0... 70 0 8 Permissible temperatures Permissible temperatures medium: 0... C electronics / environment: 0... 8 C storage:0... 00 C Electrical protection Shortcircuit protection permanent Reverse polarity protection no damage, but also no function Electromagnetic compatibility emission and immunity according to EN 66 Mechanical stability Vibration 0 g RMS (... 000 Hz) according to DIN EN 600686 Shock 00 g / msec according to DIN EN 600687 Materials Pressure port stainless steel.0 (6L) Housing stainless steel.0 (6L) Viewing glass laminated safety glass Seals (media wetted) standard: FKM option: NBR; welded version on request others on request Diaphragm stainless steel. (6 L) Media wetted parts pressure port, seals, diaphragm welded version only for pressure ports according to EN 87; possible for nominal pressure ranges P N 0 bar Explosion protection (only for 0 ma / wire) Approval AXDS 00 IBExU 06 ATEX 00 X Zone 0: II G Ex ia IIC T Ga (connector) / II G Ex ia IIB T Ga (cable) Safety techn. maximum values U i = 8 V, I i = 9 ma, P i = 660 mw, C i 0 pf, L i 0 µh Max. switching current 70 ma Permissible temperatures for environment in zone 0: 0... 60 C with p atm 0.8 bar up to. bar in zone :... 70 C Connecting cables (by factory) cable capacitance: signal line/shield also signal line/signal line: 00 pf/m cable inductance: signal line/shield also signal line/signal line: µh/m the real switching current in the application depends on the power supply unit

DS 00 7 Miscellaneous Display Current consumption (without contacts) digit, 7segmentLED display, visible range 7. x mm; digit height 0 mm, range of indication 999... +9999; accuracy 0. % ± digit; digital damping 0. 0 sec (programmable); measured value update 0.0 0 sec (programmable) wire signal output current: max. ma wire signal output current: approx. 0 ma + signal current wire signal output voltage: approx. 0 ma Ingress protection IP 67 Installation position any 6 Weight approx. 00 g Operational life > 00 x 0 6 cycles CEconformity EMC Directive: 00/08/EC Pressure Equipment Directive: 97//EC (module A) 7 6 Pressure switches are calibrated in a vertical position with the pressure connection down. If this position is changed on installation there can be slight deviation in the zero point for pressure ranges P N ± bar. 7 This directive is only valid for devices with maximum permissible overpressure > 00 bar Wiring diagrams wiresystem (current) p supply + wiresystem (current / voltage) supply + p VS supply V S supply signal + A / V I contact contact contact I/U contact Pin configuration Electrical connection Supply + Supply Signal + (only wire) Contact Contact Shield Electrical connection (dimensions in mm) Mx metal (pin) plug housing / pressure port Mx (pin) Designs 8 side display display (on request) 8 all designs in horizontal rotatable housing as standard www.bdsensors.com

8 DS 00 Mechanical connections (dimensions in mm) standard G/" DIN 8 for nominal pressure P N > 00 bar increases the length of devices without ISvesion by 9 mm and of devices with ISversion by 9 mm optionally G/" EN 87 G/" DIN 8 G/" EN 87 /" NPT /" NPT G/" flush DIN 8 (PN from 0. up to 0 bar) metric threads and other versions on request

DS 00 Ordering Code 9 DS 00 Pressure gauge absolute 7 A 0 7 A Input [bar] 0.0 0 0 0 0.6 6 0 0 0. 0 0 0.0 0 0 0 0.60 6 0 0 0.0 0 0.6 6 0. 0.0 0 0 6.0 6 0 0 0 0 0 6 6 0 0 0 0 0 60 6 0 0 00 0 0 60 6 0 0 0 00 0 0 600 6 0 0 0 X 0 9 9 9 Design Stainless steel globe housing (side display) K H Stainless steel globe housing ( display) K consult Analogue output without 0 ma / wire 0 0 V / wire, adjustable 0 ma / wire, adjustable Intrinsic safety 0 ma / wire 0 7 E Contact contact contacts Accuracy standard for P N 0. % standard for P N < 0. bar 0. % option for P N 0. % Electrical connection Male plug Mx (pin) / metal version N 9 9 Mechanical connection G/" DIN 8 G/" EN 87 G/" DIN 8 G/" EN 87 0 0 0 0 0 0 0 0 G/" DIN 8 with flush sensor F 0 0 /" NPT /" NPT N 0 0 N 0 9 9 Seals FKM without (welded version) consult NBR Special version standard 0 0 0 9 9 from 60 bar: measurement starts with ambient pressure with Ex version max. contact is possible only possible for nominal pressure ranges P N welded version only with pressure ports according to EN 87; possible for nominal pressure ranges P N Subject to change without notice.

0 Pressure switch with DIsPLAy DS 0 Intelligent Electronic Pressure Switch Stainless Steel Ceramic Sensor accuracy according to IEC 60770: 0. % FSO Nominal pressure from 0... 00 mbar up to 600 bar Contacts or independent PNP contacts, freely configurable Analogue output wire:... 0 ma wire: 0 ma / 0 0 V others on request Special characteristics indication of measured values on a digit LED display rotatable and configurable display module Optional versions ISversion Ex ia = intrinsically safe for gases pressure port PVDF specific versions The electronic pressure switch DS 0 is the successful combination of intelligent pressure switch digital display and has been specially designed for universal usage in industry applications; with flush diaphragm the DS 0 is suitable for the usage in viscous, pasty or highly contaminated media. The rotatable stainless steel housing is predestined for rough conditions and difficult installing conditions, caused by the high functionality and robustness. As standard the DS 0 offers a PNP contact and is optionally available with a second, independent contact. Additionally the DS 0 could be equipped with an analogue output Preferred areas of use are Plant and Machine Engineering Environmental Engineering (water sewage recycling) Water Hydraulic Oil

DS 0 Input pressure ranges Nominal pressure gauge [bar] 0 0. 0.6.6. 6 0 6 0 60 00 60 0 00 600 Nominal pressure abs. [bar] 0.6.6. 6 0 6 0 60 00 60 0 00 600 Level gauge [mh O] 6 0 6 0 60 00 60 0 00 600 Overpressure [bar] 0 0 0 0 0 00 00 00 00 00 600 800 Burst pressure [bar] 7 0 0 0 0 0 00 00 60 880 Vacuum resistance P N bar: unlimited vacuum resistance P N < bar: on request Contact Number, type standard: PNP contact option: independent PNP contacts Max. switching current... 0 ma / and wire: contact rating ma, shortcircuit resistant; V Switch = V S V 0... 0 V / wire: contact rating 00 ma, shortcircuit resistant Accuracy of contacts 0. % FSO Repeatability ± 0. % FSO Switching frequency wire: max. 0 Hz / wire: 0 Hz Switching cycles > 00 x 0 6 Delay time 0... 00 sec with Exprotection max. contact possible accuracy according to IEC 60770 limit point adjustment (nonlinearity, hysteresis, repeatability) Analogue output (optionally) / Supply wire current signal... 0 ma / V S =... 6 V DC permissible load: R max = [(V S V S min) / 0.0 A] response time: < 0 msec wire current signal, Exprotection... 0 ma / V S =... 8 V DC permissible load: R max = [(V S V S min) / 0.0 A] response time: < 0 msec wire current signal... 0 ma / V S = V DC ± 0 % adjustable (turndown of span :) permissible load: R max = 00 response time: < 0 msec wire voltage signal 0 0 V / V S = V DC ± 0 % adjustable (turndown of span :) permissible load: R min = 0 k response time: < 0 msec Without analogue output V S =... 6 V DC Accuracy 0. % FSO with turndown of span the analogue signal is adjusted automatically to the new measuring range Thermal effects (Offset and Span) / Permissible temperatures Thermal error ± 0. % FSO / 0 K in compensated range... 8 C Permissible temperatures medium: 0... C electronics / environment: 0... 8 C storage: 0... 00 C for pressure port of PVDF the minimum permissible temperature is 0 C Electrical protection Shortcircuit protection Reverse polarity protection Electromagnetic compatibility Mechanical stability permanent no damage, but also no function emission and immunity according to EN 66 Vibration 0 g RMS (... 000 Hz) according to DIN EN 600686 Shock 00 g / msec according to DIN EN 600687 Materials Pressure port / housing.0 (6L) PVDF (for P N 60 bar, G/ open port ).0 (6L) Housing Display housing stainless steel.0 (0) Viewing glass laminated safety glass Seals standard: FKM option: EPDM (P N 60 bar), NBR others on request Diaphragm ceramics Al O 96 % Media wetted parts pressure port, seals, diaphragm

DS 0 Explosion protection (only for 0 ma / wire) Approval AXDS 0 IBExU06ATEX00 X zone 0: II G Ex ia IIC T Ga (connector) / II G Ex ia IIB T Ga (cable) Safety technical maximum values U i = 8 V, I i = 9 ma, P i = 660 mw, C 0 nf, L i 0 µh Max. switching current 70 ma Permissible temperatures for in zone 0: 0... 60 C with p atm 0.8 bar up to. bar environment in zone :... 70 C Connecting cables cable capacitance: signal line/shield also signal line/signal line: 00 pf/m (by factory) cable inductance: signal line/shield also signal line/signal line: µh/m the real switching current in the application depends on the power supply unit Miscellaneous Display digit, 7segmentLED display, visible range 7. x mm; digit height 0 mm, range of indication 999... +9999; accuracy 0. % ± digit; digital damping 0. 0 sec (programmable); measured value update 0.0 0 sec (programmable) Option oxygen application 6 for P N bar: Oring in 70 EPDM 8 (with BAMapproval); permissible maximum values are bar / 60 C and 0 bar / 90 C for P N bar: Oring in FKM Vi 67 (with BAMapproval); permissible maximum values are bar / 0 C Current consumption (without contacts) wire signal output current: wire signal output current: wire signal output voltage: max. ma approx. 0 ma + signal current approx. 0 ma Ingress protection IP 67 Installation position any Weight approx. 00 g Operational life > 00 x 0 6 pressure cycles CEconformity EMC Directive: 00/08/EC Pressure Equipment Directive: 97//EC (module A) 7 6 not possible with flush pressure ports 7 This directive is only valid for devices with maximum permissible overpressure > 00 bar Wiring diagrams wiresystem (current) p I supply + supply contact contact VS wiresystem (current / voltage) p supply + supply signal + contact I/U contact A / V VS Pin configuration Electrical connections Supply + Supply Signal + (only wire) Contact Contact Shield Electrical connections (dimensions in mm) Mx metal (pin) plug housing / pressure port Mx (pin) Design 8 side display display (on request) 8 all designs in horizontal rotatable housing as standard www.bdsensors.com

DS 0 Mechanical connections (dimensions in mm) standard G/" DIN 8 optionally G/" DIN 8 G/" EN 87 G/" EN 87 G/" open port DIN 8 /" NPT /" NPT G/" flush DIN 8 (PN from 0. up to 0 bar) metric threads and other versions on request

DS 0 Ordering Code DS 0 Pressure gauge gauge in mh O absolute 7 A 7 A E 7 A Input [mh O] [bar] 0. 0 0 0 6 0.6 6 0 0 0 0.0 0 0 6.6 6 0. 0 0.0 0 0 60 6.0 6 0 0 00 0 0 0 60 6 6 0 0 0 00 0 0 0 600 60 6 0 0 00 0 0 60 6 0 0 0 00 0 0 600 6 0 0 0 X 0 9 9 9 Design Stainless steel globe housing (side display) K H Stainless steel globe housing ( display) K consult Analogue output without 0 ma / wire 0 0 V / wire, adjustable 0 ma / wire, adjustable Intrinsic safety 0 ma / wire 0 7 E Contact contact contacts Accuracy 0. % Electrical connection Male plug Mx (pin) / metal version N 9 9 Mechanical connection G/" DIN 8 G/" EN 87 G/" DIN 8 G/" EN 87 G/" DIN 8 with flush sensor 0 0 0 0 0 0 0 0 F 0 0 G/" DIN 8 open pressure port /" NPT /" NPT H 0 0 N 0 0 N 0 9 9 Seals FKM EPDM NBR Pressure port Stainless steel.0 (6L) PVDF B Diaphragm Ceramics Al O 96% Special version standard oxygen application 0 0 0 0 0 7 9 9 with Ex version max. contact is possible G/" flush up to bar and nominal pressure abs. on request possible for nominal pressure ranges P N 60 bar PVDF only with G/" DIN 8 open pressure port (up to 60 bar); Exprotection not possible, (min. permissible temperature 0 C) oxygen application with FKMseal up to bar or with EPDMseal up to bar possible Subject to change without notice.

Pressure switch with DIsPLAy DS 00 Electronic Pressure Switch Stainless Steel Sensor accuracy according to IEC 60770: standard: 0. % FSO option: 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 600 bar Contacts, or independent PNP contacts,freely configurable Analogue output wire:... 0 ma wire: 0 ma / 0 0 V others on request Special characteristics indication of measured values on a digit LED display rotatable and configurable display module Optional versions The electronic pressure switch DS 00 is the successful combination of intelligent pressure switch digital display and has been specially designed for numerous applications in various industrial sectors. As standard the DS 00 offers a PNP contact and a rotatable display module with digit LED display. Optional versions like e.g. an intrinsically safe version, max. contacts and an analogue output complete the profile. Preferred areas of use are Plant and Machine Engineering Heating and Air Conditioning Environmental Engineering (water sewage recycling) ISversion Ex ia = intrinsically safe for gases pressure sensor welded specific versions

6 DS 00 Input pressure range Nominal pressure gauge / abs. [bar] 0 0.0 0.6 0. 0.0 0.60.6. 6 Level gauge [mh O].6. 6 0 6 0 60 Overpressure [bar] 0. 0 0 0 0 Burst pressure [bar] 7.... 7. 7. 0 Nominal pressure gauge / abs. [bar] 0 6 0 60 00 60 0 00 600 Level gauge [mh O] 00 60 0 00 600 Overpressure [bar] 0 80 80 0 0 0 600 000 000 000 Burst pressure [bar] 0 0 0 0 0 0 000 0 0 0 Vacuum resistance P N bar: unlimited vacuum resistance; P N < bar: on request from 60 bar: measurement starts with ambient pressure Contact Standard PNP contact Options independent PNP contacts independent PNP contacts (possible with Mx, 8pin for... 0 ma/wire; 0... 0 V/wire on request) Max. switching current... 0 ma / and wire: contact rating ma, shortcircuit resistant; V switch = V S V 0... 0 V / wire: contact rating 00 ma, shortcircuit resistant Accuracy of contacts standard: P N < 0. bar: ± 0. % FSO P N 0. bar: ± 0. % FSO option: P N 0. bar: ± 0. % FSO Repeatability 0. % FSO Switching frequency max. 0 Hz Switching cycles > 00 x 0 6 Delay time 0... 00 sec max. contact for wire current signal with plug ISO 00 as well as wire current signal with ISprotection no contact possible with wire in combination with plug ISO 00 Analogue output (optionally) / Supply wire current signal... 0 ma / V S =... 6 V DC permissible load: R max = [(V S V S min) / 0.0 A] response time: < 0 msec wire current signal with ISprotection... 0 ma / V S =... 8 V DC permissible load: R max = [(V S V S min) / 0.0 A] response time: < 0 msec wire current signal... 0 ma / V S = 9... 0 V DC adjustable (turndown of span :) permissible load: R max = 00 response time: < sec wire voltage signal 0 0 V / V S =... 6 V DC permissible load: R min = 0 k response time: < msec without analogue output V S =... 6 V DC Accuracy standard: P N < 0. bar: ± 0. % FSO; P N 0. bar: ± 0. %FSO option: P N 0. bar: ± 0. % FSO accuracy according to IEC 60770 limit point adjustment (nonlinearity, hysteresis, repeatability) with turndown of span the analogue signal is adjusted automatically to the new measuring range Thermal effects (Offset and Span) Nominal pressure P N [bar] 0 < 0.0 0.0 Tolerance band [% FSO] ± 0.7 ± ± 0.7 in compensated range [ C] 0... 8 0... 70 0 8 Permissible temperatures Permissible temperatures medium: 0... C electronics / environment: 0... 8 C storage: 0... 00 C Electrical protection Shortcircuit protection permanent Reverse polarity protection no damage, but also no function Electromagnetic compatibility emission and immunity according to EN 66 Mechanical stability Vibration 0 g RMS (... 000 Hz) according to DIN EN 600686 Shock 00 g / msec according to DIN EN 600687 Materials Pressure port stainless steel.0 (6 L) Housing stainless steel.0 (6 L) Display housing PA 6.6, polycarbonate Seals (media wetted) standard: FKM option: NBR; welded version others on request Diaphragm stainless steel. (6 L) Media wetted parts pressure port, seals, diaphragm welded version only for pressure ports according to EN 87; possible for nominal pressure ranges P N 0 bar

DS 00 7 Explosion protection (only for 0 ma / wire) Approval AXDS 00 IBExU 06 ATEX 00 X zone : II G Ex ia IIC T Gb (connector) / II G Ex ia IIB T Gb (cable) Safety technical maximum values U i = 8 V, I i = 9 ma, P i = 660 mw, C 0 nf, L i 0 µh Max. switching current 6 70 ma (max. permissible inductivity:.7 mh) Permissible temperatures for environment 0... 70 C Connecting cables cable capacitance: signal line/shield also signal line/signal line: 60 pf/m (by factory) cable inductance: signal line/shield also signal line/signal line: µh/m 6 the real switching current in the application depends on the power supply unit Miscellaneous Display digit, red 7segmentLED display, digit height 7 mm, range of indication 999... +9999; accuracy 0. % ± digit; digital damping 0. 0 sec (programmable); measured value update 0.0 0 sec (programmable) Current consumption wire signal output current: max. ma (without contacts) wire signal output current: approx. ma + signal current wire signal output voltage: approx. ma Ingress protection IP 6 Installation position any 7 Weight Operational life min. 60 g (depending on mechanical connection) > 00 x 0 6 cycles CEconformity EMC Directive: 00/08/EC Pressure Equipment Directive: 97//EC (module A) 8 7 Pressure switches are calibrated in a vertical position with the pressure connection down. If this position is changed on installation there can be slight deviation in the zero point for pressure ranges P N bar. 8 This directive is only valid for devices with maximum permissible overpressure > 00 bar Wiring diagrams wiresystem (current) wiresystem (current / voltage) p I supply + supply contact contact A V S p I/U supply + supply signal + contact contact contact contact A/V V S Pin configuration Electrical connection Supply + Supply Signal + (only wire) Contact Contact Contact Contact Shield Mx plastic (pin) via pressure port Electrical connections (dimensions in mm) Mx metal (pin) plug housing/ pressure port Mx plastic (8pin) 6 7 via pressure port ISO 00 ground contact Binder series 7 (pin) plug housing/ pressure port cable colours (DIN 700) wh (white) bn (brown) gn (green) gy (grey) pk (pink) ye/gn (yellow/green) cable outlet PVC Ø =.9mm cable outlet PUR Ø =.7mm Mx (pin) Mx (8pin) ISO 00 Binder series 7 (pin) cable outlet 9 9 different cable types and lengths available; standard: m PVC cable (without ventilation tube, permissible temperature:... 70 C) www.bdsensors.com

8 DS 00 Mechanical connections (dimensions in mm) standard optionally G/" EN 87 G/" DIN 8 G/" EN 87 G/" DIN 8 /" NPT /" NPT for nominal pressure P N > 00 bar increases the length of devices without ISversion by 9 mm and of devices with ISversion by 9 mm optionally for P N from 0. up to 0 bar G/" flush G/" flush DIN 8 DIN 8 (absolute pressure on request) metric threads and other versions on request

DS 00 Ordering Code 9 DS 00 Pressure gauge in bar gauge in mh O absolute in bar 7 8 0 7 8 H 7 8 Input [mh O] [bar] 0.0 0 0 0.6 0.6 6 0 0. 0. 0 0 0.0 0 0 0 6 0.60 6 0 0 0 0.0 0 0 6.6 6 0. 0 0.0 0 0 60 6.0 6 0 0 00 0 0 0 60 6 6 0 0 0 00 0 0 0 600 60 6 0 0 00 0 0 60 6 0 0 0 00 0 0 600 6 0 0 0 X 0 9 9 9 Analogue output without 0 ma / wire 0 0 V / wire 0 7 E 0 ma / wire, adjustable Intrinsic safety 0 ma / wire Contact, contact, contacts contacts Accuracy standard for P N > 0, bar 0. % standard for P N 0, bar 0. % option for P N 0, bar 0. % Electrical connection Male plug Mx (pin) / plastic version N 0 Male plug Mx (8pin) / plastic version M 0 Male plug Mx (pin) / metal version N Male and female plug ISO 00 Male plug Binder series 7 (pin) Cable outlet incl. cable 0 0 0 0 T A 0 9 9 Mechanical connection G/" DIN 8 G/" EN 87 G/" DIN 8 G/" EN 87 0 0 0 0 0 0 0 0 6 G/" DIN 8 with flush sensor 6 G/" DIN 8 with flush sensor F 0 0 K 0 0 /" NPT /" NPT N 0 0 N 0 9 9 Seals FKM 7 without (welded version) NBR Special version standard 0 0 0 9 9 from 60 bar: measurement starts with ambient pressure with Ex version max. contact is possible with connector ISO 00 and output wire version only max. contact possible; with wire version no contact possible contacts and Mx, 8pin only possible in combination and together with... 0 ma/wire; 0... 0 V/wire on request standard: m PVC cable without ventilation tube, others on request 6 not possible for nominal pressure P N > 0 bar; also not possible for vacuum ranges; for G/ flush nominal pressure abs. on request 7 welded version only with pressure ports according to EN 87; possible for nominal pressure ranges P N 0 bar Subject to change without notice.

0 Pressure switch with DIsPLAy DS 0 Electronic Pressure Switch Ceramic Sensor accuracy according to IEC 60770: 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 600 bar Contacts, or independent PNP contacts, freely configurable Analogue output wire:... 0 ma wire: 0 ma / 0 0 V others on request Special characteristics indication of measured values on a digit LED display rotatable and configurable display module Optional versions The electronic pressure switch DS 0 is the successful combination of intelligent pressure switch digital display and has been specially designed for universal usage in industry applications. The DS 0 is available with flush pressure ports for viscous, pasty and highly contaminated media. As standard the DS 0 offers a PNP contact and a rotable display module with digit LED display. Optional versions like e.g. an intrinsically safe version, max. contacts and an analogue output complete the profile. Preferred areas of use are Plant and Machine Engineering Environmental Engineering (water sewage recycling) ISversion Ex ia = intrinsically safe for gases pressure port PVDF specific versions

DS 0 Input pressure range Nominal pressure gauge [bar] 0 0. 0.6.6. 6 0 6 0 60 00 60 0 00 600 Nominal pressure abs. [bar] 0.6.6. 6 0 6 0 60 00 60 0 00 600 Level gauge [mh O] 6 0 6 0 60 00 60 0 00 600 Overpressure [bar] 0 0 0 0 0 00 00 00 00 00 600 800 Burst pressure [bar] 7 0 0 0 0 0 00 00 60 880 Vacuum resistance P N bar: unlimited vacuum resistance P N < bar: on request PVDF pressure port possible for nominal pressure ranges up to 60 bar Contact Standard PNP contact Options independent PNP contacts independent PNP contacts (possible with Mx, 8pin for... 0 ma/wire; 0... 0 V/wire on request) Max. switching current... 0 ma / and wire: contact rating ma, shortcircuit resistant; V Switch = V S V 0... 0 V / wire: contact rating 00 ma, shortcircuit resistant Accuracy of contacts 0. % FSO Repeatability ± 0. % FSO Switching frequency max. 0 Hz Switching cycles > 00 x 0 6 Delay time 0... 00 sec max. contact for wire current signal with plug ISO 00 as well as wire current signal with ISprotection no contact possible with wire in combination with plug ISO 00 Analogue output (optionally) / Supply wire current signal... 0 ma / V S =... 6 V DC permissible load: R max = [(V S V S min) / 0.0 A] response time: < 0 msec wire current signal with ISprotection... 0 ma / V S =... 8 V DC permissible load: R max = [(V S V S min) / 0.0 A] response time: < 0 msec wire current signal... 0 ma / V S = 9... 0 V DC adjustable (turndown of span :) permissible load: R max = 00 response time: < 0, sec wire voltage signal 0 0 V / V S =... 6 V DC permissible load: R min = 0 k response time: < 0 msec Without analogue output V S =... 6 V DC Accuracy 0. % FSO accuracy according to IEC 60770 limit point adjustment (nonlinearity, hysteresis, repeatability) with turndown of span the analogue signal is adjusted automatically to the new measuring range Thermal effects (Offset and Span) / Permissible temperatures Thermal error ± 0. % FSO / 0 K in compensated range... 8 C Permissible temperatures medium: 0... C electronics / environment: 0... 8 C storage: 0... 00 C for pressure port of PVDF the minimum permissible temperature is 0 C Electrical protection Shortcircuit protection permanent Reverse polarity protection no damage, but also no function Electromagnetic compatibility emission and immunity according to EN 66 Mechanical stability Vibration 0 g RMS (... 000 Hz) according to DIN EN 600686 Shock 00 g / msec according to DIN EN 600687 Materials Pressure port / housing pressure port Standard: Option for G/" open port (up to 60 bar): Options for G/" flush (0.6 bar P N bar): Display housing PA 6.6, polycarbonate Seals (media wetted) standard: FKM option: EPDM (P N 60 bar), NBR others on request Diaphragm ceramics Al O 96 % Media wetted parts pressure port, seals, diaphragm stainless steel.0 PVDF PVDF housing stainless steel.0 stainless steel.0 PVDF

DS 0 Explosion protection (only for 0 ma / wire) Approval AXDS 0 IBExU 06 ATEX 00 X zone : II G Ex ia IIC T Gb (connector) / II G Ex ia IIB T Gb (cable) Safety tech. maximum values U i = 8 V, I i = 9 ma, P i = 660 mw, C 0 nf, L i 0 µh Max. switching current 6 70 ma (max. permissible inductivity:.7 mh) Permissible temperatures for environment 0... 70 C Connecting cables cable capacitance: signal line/shield also signal line/signal line: 60 pf/m (by factory) cable inductance: signal line/shield also signal line/signal line: µh/m 6 the real switching current in the application depends on the power supply unit Miscellaneous Display digit, red 7segmentLED display, digit height 7 mm, range of indication 999... +9999; accuracy 0. % ± digit; digital damping 0. 0 sec (programmable); measured value update 0.0 0 sec (programmable) Option oxygen application 7 for P N bar: Oring in 70 EPDM 8 (with BAMapproval); permissible maximum values are bar / 60 C and 0 bar / 90 C for P N bar: Oring in FKM Vi 67 (with BAMapproval); permissible maximum values are bar / 0 C Current consumption wire signal output current: max. ma (without contacts) wire signal output current: approx. ma + signal current wire signal output voltage: approx. ma Ingress protection IP 6 Installation position any Weight approx. 00 g Operational life > 00 x 0 6 cycles CEconformity EMC Directive: 00/08/EC Pressure Equipment Directive: 97//EC (module A) 8 7 not possible with flush pressure ports 8 This directive is only valid for devices with maximum permissible overpressure > 00 bar Wiring diagrams wiresystem (current) wiresystem (current / voltage) p supply + p supply + V S supply A V S supply signal + contact A/V I contact contact I/U contact contact contact Pin configuration Electrical connection Supply + Supply Signal + (only wire) Contact Contact Contact Contact Shield Mx plastic (pin) via pressure port Electrical connections (dimensions in mm) Mx metal (pin) plug housing/ pressure port Mx plastic (8pin) 6 7 via pressure port ISO 00 ground contact Binder series 7 (pin) plug housing/ pressure port cable colours (DIN 700) wh (white) bn (brown) gn (green) gy (grey) pk (pink) ye/gn (yellow/green) cable outlet PVC Ø =.9mm cable outlet PUR Ø =.7mm Mx (pin) Mx (8pin) ISO 00 Binder series 7 (pin) cable outlet 9 9 different cable types and lengths available, permissible temperature depends on kind of cable; standard: m PVC cable (without ventilation tube, permissible temperature:... 70 C)

DS 0 Mechanical connections (dimensions in mm) G/" EN 87 G/" DIN 8 G/" EN 87 /" NPT /" NPT G/ DIN 8 G/" (DIN 8) G/" open port semiflush; M0x. 0 metric threads and others on request optionally for P N from 0.6 up to 60 bar gauge G/" flush (DIN 8) 0 possible for nominal pressure ranges P N

DS 0 Ordering Code Pressure 7 8 7 8 E 7 8 absolute in bar Input [mh O] [bar] 0. 0 0 0 6 0.6 6 0 0 0 0.0 0 0 6.6 6 0. 0 0.0 0 0 60 6.0 6 0 0 00 0 0 0 60 6 6 0 0 0 00 0 0 0 600 60 6 0 0 00 0 0 60 6 0 0 0 00 0 0 600 6 0 0 0 X 0 9 9 9 Analogue output without 0 ma / wire 0 0 V / wire 0 ma / wire, adjustable Intrinsic safety 0 ma / wire Contact contact, contacts, contacts Accuracy 0. % Electrical connection Male plug Mx (pin) / plastic version Male plug Mx (8pin) / plastic version Male plug Mx (pin) / metal version Male and female plug ISO 00 Male plug Binder series 7 (pin) Cable outlet incl. cable Mechanical connection G/" DIN 8 G/" EN 87 G/" DIN 8 G/" EN 87 G/" DIN 8 with flush sensor G/" DIN 8 with 6 flush sensor G/" DIN 8 open pressure port /" NPT 0 7 E 0 0 0 0 T A 0 9 9 0 0 0 0 0 0 0 0 H 0 0 N 0 0 N 0 9 9 /" NPT Seals FKM 7 EPDM NBR Pressure port Stainless steel.0 (6L) PVDF 8 B Diaphragm Ceramics Al O 96% Special version DS 0 with Ex version max. contact possible gauge in bar gauge in mh O standard oxygen application 9 with connector ISO 00 and output wire version only max. contact possible; with wire version no contact possible contacts and Mx, 8pin only possible in combination and together with... 0 ma/wire; 0... 0 V/wire on request standard: m PVC cable without ventilation tube (permissible temperature: 70 C), others on request possible for nominal pressure ranges P N 0.6 bar up to PN bar gauge, absolute on request 6 possible for nominal pressure ranges P N 0.6 bar up to P N 60 bar gauge 7 possible for nominal pressure ranges P N 60 bar 8 PVDF only with G/" DIN 8 open pressure port (up to 60 bar) and G/" DIN 8 with flush sensor (0.6 bar P N bar), (min. permissible temperature 0 C) 9 oxygen application with FKMseal up to bar or with EPDMseal up to bar possible, flush version on request N 0 M 0 N F 0 0 K 0 0 0 0 0 0 0 7 Subject to change without notice.

Pressure switch with DIsPLAy DS 0 Electronic Pressure Switch welded, dry Stainless Steel Sensor accuracy according to IEC 60770: 0. % FSO Nominal pressure from 0... 6 bar up to 0... 600 bar Contacts, or independent PNP contacts, freely configurable Analogue output wire:... 0 ma wire: 0 ma / 0 0 V others on request Special characteristics indication of measured values on a digit LED display rotatable and configurable display module Optional versions The electronic pressure switch DS 0 is the successful combination of robust pressure transmitter digital display and has been specially designed for numerous applications in various industrial sectors. As standard the DS 0 offers a PNP contact and a rotable display module with digit LED display.the transmitters are suitable for an unrestricted use in oxygen applications up to 600 bar and an intrinsically safe ISVersion. Preferred areas of use are Medical Technology Plant and Machine Engineering Refrigeration ISversion Ex ia = intrinsically safe for gases oxygen application specific versions Oxygen application

6 DS 0 Input pressure range Nominal pressure gauge [bar] 6 0 6 0 60 00 60 0 00 600 Overpressure [bar] 70 0 0 0 0 700 00 00 Burst pressure [bar] 8 8 7 0 0 80 80 70 800 800 Vacuum resistance unlimited Contact Number, type standard: PNP contact option: independent PNP contacts independent PNP contacts (possible with Mx 8pin for 0 ma / wire) Max. switching current... 0 ma / and wire: contact rating ma, shortcircuit resistant; V switch = V S V 0... 0 V / wire: contact rating 00 ma, shortcircuit resistant Accuracy of contacts ± 0. % FSO Repeatability 0. % FSO Switching frequency max. 0 Hz Switching cycles > 00 x 0 6 Delay time 0... 00 sec with ISprotection max. contact possible Analogue output (optionally) / Supply wire current signal... 0 ma / V S =... 6 V DC permissible load: R max = [(V S V S min) / 0.0 A] wire current signal with... 0 ma / V S =... 8 V DC ISprotection permissible load: R max = [(V S V S min) / 0.0 A] wire current signal... 0 ma / V S = 9... 0 V DC permissible load: R max = 00 k adjustable (turndown of span up to :) wire voltage signal 0 0 V / V S =... 6 V DC permissible load: R min = 0 k without analogue output V S =... 6 V DC Accuracy ± 0. % FSO accuracy according to IEC 60770 limit point adjustment (nonlinearity, hysteresis, repeatability) with turndown of span the analogue signal is adjusted automatically to the new measuring range Thermal effects (Offset and Span) Thermal error ± 0. % FSO / 0 K in compensated range 0 70 C Permissible temperatures Permissible temperatures medium: 0... C electronics / environment: 0... 8 C storage: 0... 00 C Electrical protection Shortcircuit protection Reverse polarity protection permanent no damage, but also no function Electromagnetic compatibility emission and immunity according to EN 66 Mechanical stability Vibration 0 g RMS (... 000 Hz) according to DIN EN 600686 Shock 00 g / msec according to DIN EN 600687 Materials Pressure port stainless steel.7 (6 Ti) Housing stainless steel.0 (6 L) Display housing PA 6.6, polycarbonate Seals (media wetted) none (welded) Diaphragm stainless steel. (7PH) Media wetted parts pressure port, diaphragm Explosion protection (only for 0 ma / wire) Approval AXDS 0 IBExU 06 ATEX 00 X Zone : II G Ex ia IIC T Gb (connector) / II G Ex ia IIB T Gb (cable) Safety technical maximum values U i = 8 V, I i = 9 ma, P i = 660 mw, C i 0 nf, L i 0 µh Max. switching current 70 ma (max. permissible inductivity:.7 mh) Permissible temperatures for environment 0... 70 C Connecting cables (by factory) cable capacitance: signal line/shield also signal line/signal line: 60 pf/m cable inductance: signal line/shield also signal line/signal line: µh/m the real switching current in the application depends on the power supply unit response time: < 0 msec response time: < 0 msec

DS 0 7 Miscellaneous Display Current consumption (without contacts) Ingress protection IP 6 Installation position digit, red 7segmentLED display, digit height 7 mm, digit width.8 mm (angle 0 ); range of indication 999... +9999; accuracy 0. % ± digit; digital damping 0. 0 sec (programmable); measured value update 0.0 0 sec (programmable) wire signal output current: max. ma wire signal output current: approx. ma + signal current wire signal output voltage: approx. ma any Weight min. 60 g (depending on mechanical connection) CEconformity EMC Directive: 00/08/EC Pressure Equipment Directive: 97//EC (module A) This directive is only valid for devices with maximum permissible overpressure > 00 bar Wiring diagrams wiresystem (current) p supply + wiresystem (current / voltage) p supply + VS supply A R L V S supply signal + contact A/V I contact contact R L I/U contact contact contact Pin configuration Electrical connection Mx plastic (pin) Supply + Supply Signal + (only wire) Contact Contact Contact Contact Shield via pressure port Electrical connections (dimensions in mm) Mx metal (pin) plug housing / pressure port Mx plastic (8pin) 6 7 via pressure port ISO 00 ground contact cable colours (DIN 700) wh (white) bn (brown) gn (green) gy (grey) pk (pink) ye/gn (yellow/green) PVCcable Ø=.9mm, PURcable Ø=.7mm Mx (pin) Mx (8pin) ISO 00 Binder series 7 (pin) cable outlet 6 6 different cable types and lengths available, permissible temperature depends on kind of cable; standard: m PVC cable (without ventilation tube, permissible temperature:... 70 C) www.bdsensors.com

8 DS 0 Mechanical connections (dimensions in mm) standard option G/" EN 87 G/" EN 87 /" NPT metric threads and other versions on request

DS 0 Ordering Code 9 DS 0 Pressure gauge in bar 7 8 Input [bar] 6.0 6 0 0 0 0 0 6 6 0 0 0 0 0 60 6 0 0 00 0 0 60 6 0 0 0 00 0 0 600 6 0 0 9 9 9 Analogue output without 0 ma / wire 0 0 V / wire 0 ma / wire Intrinsic safety 0 ma / wire 0 7 E Contact contact contacts contacts Accuracy standard 0. % Electrical connection Male plug Mx (pin) / plastic version N 0 Male plug Mx (8pin) / plastic version M 0 Male plug Mx (pin) / metal version N Male and female plug ISO 00 Male plug Binder series 7 (pin) Cable outlet incl. cable 0 0 0 0 T A 0 9 9 Mechanical connection G/" EN 87 G/" EN 87 /" NPT 0 0 0 0 N 0 9 9 Seals without (welded version) Special version standard 0 0 0 oxygen application 0 0 7 9 9 from 60 bar: measurement starts with ambient pressure with Ex version max. contact is possible contacts and Mx, 8pin only possible in combination and together with... 0 ma/wire; 0... 0 V/wire on request with connector ISO 00 and output wire version only max. contact possible; with wire version no contact possible different cable types and lengths deliverable, standard: m PVC cable without ventilation tube, optionally cable with ventilation tube Subject to change without notice.

0 Pressure switch with DIsPLAy DS 0 Electronic Pressure Switch Without Media Isolation accuracy according to IEC 60770: 0. % FSO Nominal pressure from 0... 0 mbar up to 0... 000 mbar Contacts, or independent contacts freely configurable Analogue output wire:... 0 ma wire: 0 ma / 0 0 V others on request Special characteristics indication of measured values on a digit LED display rotatable and configurable display module Optional versions The electronic pressure switch DS 0 is the successful combination of intelligent pressure switch digital display and has been specially designed for measuring of very small overpressure and for vacuum applications. Permissible media are gases, pressurized air and thin non aggressive media. As standard the DS 0 offers a PNPcontact and a rotable display module. Additional features like e.g. an intrinsically safe version, max. contacts and an analogue output complete the profile. Preferred areas of use are Plant and Machine Engineereing Heating and Air Conditioning ISversion Ex ia = intrinsically safe for gases specific versions Laboratory Techniques

DS 0 Input pressure range Nominal pressure gauge [mbar] 000... 0 0 6 0 60 00 60 0 00 600 000 Overpressure [bar] 0. 0. 0. 0. 0. Burst pressure [bar] 0. 0. 0.7 0.7 0.7. Contact Standard PNP contact Options independent PNP contacts independent PNP contacts (possible with Mx, 8pin for... 0 ma/wire; 0... 0 V/wire on request) Max. switching current... 0 ma / and wire: contact rating ma, shortcircuit resistant; V switch = V S V 0... 0 V / wire: contact rating 00 ma, shortcircuit resistant Accuracy of contacts standard: ± 0. % FSO nominal pressure 00 mbar: ± 0. % FSO Repeatability 0. % FSO Switching frequency max. 0 Hz Switching cycles > 00 x 0 6 Delay time 0... 00 sec max. contact for wire current signal with plug ISO 00 as well as wire current signal with Exprotection no contact possible with wire in combination with plug ISO 00 Analogue output (optionally) / Supply wire current signal... 0 ma / V S = 8... V DC permissible load: R max = [(V S V S min) / 0,0 A] response time: < 0 msec wire current signal with... 0 ma / V S = 7... 8 V DC Exprotection permissible load: R max = [(V S V S min) / 0,0 A] response time: < 0 msec wire current signal... 0 ma / V S = 9... 0 V DC adjustable (turndown of span max. :) permissible load: R max = 00 response time: < sec wire voltage signal 0... 0 V / V S =... 6 V DC permissible load: R min = 0 k response time: < msec without analogue output V S =... 6 V DC Accuracy standard: ± 0. % FSO nominal pressure 00 mbar: ± 0. % FSO with turndown of span the analogue signal is adjusted automatically to the new measuring range accuracy according to IEC 60770 limit point adjustment (nonlinearity, hysteresis, repeatability) Thermal effects (Offset and Span) Nominal pressure P N [mbar] 000... 0 00 00 > 00 Tolerance band [% FSO] 0.7. 0.7 in compensated range [ C] 0... 8 0... 0 0 70 0... 8 Permissible temperatures Permissible temperatures medium: 0... C electronics / environment: 0... 8 C storage: 0... 00 C Electrical protection Shortcircuit protection permanent Reverse polarity protection no damage, but also no function Electromagnetic compatibility emission and immunity according to EN 66 Mechanical stability Vibration 0 g RMS (... 000 Hz) according to DIN EN 600686 Shock 00 g / msec according to DIN EN 600687 Materials Pressure port stainless steel.0 (6L) Housing stainless steel.0 (6L) Display housing PA 6.6, Polycarbonate Seal (media wetted) FKM Sensor stainless steel.0 (6L), silicon, Epoxy or RTV, glass Media wetted parts pressure port, seal, sensor Explosion protection (for wire current signal) Approval AXDS 0 IBExU 06 ATEX 00 X zone : II G Ex ia IIC T Gb (connector) / II G Ex ia IIB T Gb (cable) Safety technical maximum values U i = 8 V, I i = 9 ma, P i = 660 mw, C 0 nf, L i 0 µh Max. switching current 70 ma (max. permissible inductivity:.7 mh) Permissible temperatures for environment 0... 70 C Connecting cables (by factory) cable capacitance: signal line/shield also signal line/signal line: 60 pf/m cable inductance: signal line/shield also signal line/signal line: µh/m the real switching current in the application depends on the power supply unit

DS 0 Miscellaneous Display digit, red 7segmentLED display, digit height 7 mm, range of indication 999... +9999; accuracy 0. % ± digit; digital damping 0. 0 sec (programmable); measured value update 0.0 0 sec (programmable) Current consumption wire signal output current: max. ma (without contacts) wire signal output current: approx. ma + signal current wire signal output voltage: approx. ma Ingress protection IP 6 Installation position Weight Operational life CEconformity Wiring diagrams wiresystem (current) any approx. 80 g > 00 x 0 6 cycles EMC Directive: 00/08/EC wiresystem (current / voltage) p supply + p supply + VS supply A V S supply signal + contact A/V I contact contact I/U contact contact contact Pin configuration Electrical connection Supply + Supply Signal + (only wire) Contact Contact Contact Contact Shield Mx plastic (pin) via pressure port Electrical connections (dimensions in mm) Mx metal (pin) plug housing/ pressure port Mx plastic (8pin) 6 7 via pressure port ISO 00 ground contact Binder series 7 (pin) plug housing/ pressure port cable colours (DIN 700) wh (white) bn (brown) gn (green) gy (grey) pk (pink) ye/gn (yellow / green) mbar mbar mbar mbar mbar cable outlet PVC Ø =.9mm cable outlet PUR Ø =.7mm Mx (pin) Mx (8pin) ISO 00 Binder series 7 (pin) cable outlet different cable types and lengths available; standard: m PVC cable (without ventilation tube)

DS 0 Mechanical connections (dimensions in mm) standard optionally mbar G/" EN 87 G/" DIN 8 G/" DIN 8 G/" EN 87 G/" open port / NPT / NPT metric threads and other versions on request

DS 0 Ordering Code DS 0 Pressure gauge 7 8 A Input [mbar] 0 0 0 0 6 0 6 0 0 0 0 0 0 0 60 0 6 0 0 00 0 0 0 60 6 0 0 0 0 0 00 0 0 0 600 6 0 0 0 000 0 0 000 0 X 0 9 9 9 Analogue output without 0 ma / wire 0 0 V / wire 0 ma / wire, adjustable Intrinsic safety 0 ma / wire 0 7 E Contact, contact, contacts contacts Accuracy standard for P N > 0. bar 0. % standard for P N 0. bar 0. % Electrical connection Male plug Mx (pin) / plastic version N 0 Male plug Mx (8pin) / plastic version M 0 Male plug Mx (pin) / metal version N Male and female plug ISO 00 Male plug Binder series 7 (pin) Cable outlet incl. cable 0 0 0 0 T A 0 9 9 Mechanical connection Seals G/" DIN 8 G/" EN 87 G/" DIN 8 G/" EN 87 G/" DIN 8 open pressure port /" NPT /" NPT Special version FKM standard 0 0 0 0 0 0 0 0 H 0 0 N 0 0 N 0 9 9 0 0 0 9 9 with Ex version max. contact is possible with connector ISO 00 and output wire version only max. contact possible; with wire version no contact possible contacts and Mx, 8pin only possible in combination and together with... 0 ma/wire; 0... 0 V/wire on request standard: m PVC cable without ventilation tube (permissible temperature: 70 C), others on request Subject to change without notice.

Pressure switch with DIsPLAy DS Electronic Pressure Switch for very high pressure Thinfilm Sensor accuracy according to IEC 60770: standard: 0. % FSO Nominal pressure from 0... 600 bar up to 0... 00 bar Contacts, or independent PNP contacts, freely configurable Analogue output wire:... 0 ma wire: 0 ma / 0 0 V others on request Special characteristics indication of measured values on a digit LED display pressure sensor welded extremely robust and excellent longterm stability The electronic pressure switch DS for very high pressure up to 00 bar has been designed especially for use in plant and machine engineering as well as in mobile hydraulics. The DS has one contact with standard version, this can optionally be upgraded up to four independent contacts. Via the rotatable modul with an integrated digit display the DS can be programmed easily and comfortably. Preferred areas of use are Plant and Machine Engineering Commercial Vehicles and Mobile Hydraulics Optional versions adjustability of span and offset (... 0 ma / wire) specific versions

6 DS Input pressure range Nominal pressure gauge [bar] 600 000 600 000 00 Overpressure [bar] 800 00 00 800 800 only available with pressure port G/ EN 87 Contact Standard PNP contact Options independent PNP contacts independent PNP contacts (possible with Mx, 8pin for... 0 ma/wire) Max. switching current... 0 ma / and wire: contact rating ma, shortcircuit resistant; V switch = V S V 0... 0 V / wire: contact rating 00 ma, shortcircuit resistant Accuracy of contacts standard: ± 0. % FSO Repeatability 0. % FSO Switching frequency max. 0 Hz Switching cycles > 00 x 0 6 Delay time 0... 00 sec max. contact for wire current signal with plug ISO 00 no contact possible with wire in combination with plug ISO 00 Analogue output (optionally) / Supply wire current signal... 0 ma / V S =... 6 V DC permissible load: R max = [(V S V S min) / 0.0 A] response time: < 0 msec wire current signal... 0 ma / V S = 9... 0 V DC adjustable (turndown of span :) permissible load: R max = 00 response time: < sec wire voltage signal 0 0 V / V S =... 6 V DC permissible load: R min = 0 k response time: < msec without analogue output V S =... 6 V DC Accuracy standard: ± 0. %FSO IEC 60770 accuracy according to IEC 60770 limit point adjustment (nonlinearity, hysteresis, repeatability) with turndown of span the analogue signal is adjusted automatically to the new measuring range Thermal effects (Offset and Span) Thermal error [% FSO] ± 0. / 0 K in compensated range [ C] 0... 8 Permissible temperatures Permissible temperatures medium: 0... 0 C electronics / environment:... 8 C storage: 0... 00 C Electrical protection Shortcircuit protection Permanent Reverse polarity protection no damage, but also no function Electromagnetic compatibility emission and immunity according to EN 66 Mechanical stability Vibration Shock Materials 0 g RMS (... 000 Hz) 00 g / msec Pressure port stainless steel. (7 PH) Housing stainless steel.0 (6 L) Display housing PA 6.6, polycarbonate Seals (media wetted) none (welded version) Diaphragm stainless steel. (7 PH) Media wetted parts pressure port, diaphragm Miscellaneous Display digit, red 7segmentLED display, digit height 7 mm, range of indication 999... +9999; accuracy 0. % ± digit; digital damping 0. 0 sec (programmable); measured value update 0.0 0 sec (programmable) Current consumption wire signal output current: max. ma (without contacts) wire signal output current: approx. ma wire signal output voltage: approx. 7 ma + signal current Ingress protection IP 6 Installation position Weight Operational life any min. 00 g (depending on mechanical connection) > 00 x 0 6 cycles CEconformity EMC Directive: 00/08/EC Pressure Equipment Directive: 97//EC (module A)

DS 7 Wiring diagrams wiresystem (current) wiresystem (current / voltage ) p I p supply + supply + V S supply A supply contact contact signal + contact contact I/U contact contact A/V V S max. contacts possible Pin configuration Electrical connection Supply + Supply Signal + (only wire) Contact Contact Contact Contact Shield Mx plastic (pin) via pressure port Electrical connections (dimensions in mm) Mx metal (pin) plug housing/ pressure port Mx plastic (8pin) 6 7 via pressure port ISO 00 ground contact Binder series 7 (pin) plug housing/ pressure port cable colours (DIN 700) wh (white) bn (brown) gn (green) gy (grey) pk (pink) ye/gn (yellow / green) cable outlet PVC Ø =.9mm cable outlet PUR Ø =.7mm Mx (pin) Mx (8pin) ISO 00 Binder series 7 (pin) cable outlet 6 6 different cable types and lengths available; standard: m PVC cable (without ventilation tube, permissible temperature:... 70 C) Mechanical connections (dimensions in mm) standard option G/" DIN 87 M 0 x, internal thread This data sheet contains product specification, properties are not guaranteed. Subject to change without notice. www.bdsensors.com

8 DS Ordering Code DS Pressure gauge 7 8 B Input [bar] 600 6 0 0 000 0 0 600 6 0 000 0 0 00 0 9 9 9 9 Analogue output without 0 0 ma / wire 0 0 V / wire 0 ma / wire, adjustable 7 9 Contact contact contacts contacts Accuracy 0. % 9 Electrical connection Male plug Mx (pin) / plastic version Male plug Mx (8pin) / plastic version Male plug Mx (pin) / metal version Male and female plug ISO 00 Male plug Binder series 7 (pin) Cable outlet incl. cable Mechanical connection G/" DIN 87 M0x. internal thread Seals without (welded version) Special version standard N 0 M 0 N 0 0 0 0 T A 0 9 9 9 0 0 D 8 9 9 9 9 0 0 0 9 9 9 consult consult consult consult consult consult consult only available with pressure port G/" EN 87 with connector ISO 00 and output wire version only max. contact possible; with wire version no contact possible contacts and Mx, 8pin only possible in combination and together with... 0 ma/wire; 0... 0 V/wire on request standard: m PVC cable without ventilation tube, others on request According to EN 87, the pressure port and the complement, at pressure over 000 bar must be preferably made of stainless steel with a tensile strength of R P > 60 N/mm² in accordance with DIN 70. The maximum allowed pressure is 600 bar! Subject to change without notice.

Pressure switch with DIsPLAy 9 DS 00P Intelligent Electronic Pressure Switch Stainless Steel Process Connections With Flush Welded Stainless Steel Diaphragm accuracy according to IEC 60770: standard: 0. % FSO option: 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 0 bar Contacts or independent PNP contacts, freely configurable Analogue output wire:... 0 ma wire: 0 ma / 0 0 V others on request Special characteristics indication of measured values on a digit LED display rotatable and configurable display module configurable contacts (switch on / switch off points, hysteresis / window mode, switch on / switch off delay) hygienic version Optional versions ISversion Ex ia = intrinsically safe for gases specific versions The electronic pressure switch DS 00P is the successful combination of intelligent pressure switch digital display and has been developed for process industry; especially for food / beverage and pharmaceutical industry. As standard the DS 00P offers a PNP contact and a rotatable display module with digit LED display. Optional versions like e.g. an intrinsically safe version, max. contacts and an analogue output complete the profile. Preferred areas of use are Food and Berverage Pharmaceutical Industry Material and test certificates inspection certificate. according to EN 00 test report. according to EN 00 70

0 DS 00P Input pressure range Nominal pressure gauge / abs. [bar]... 0 0. 0.6 0. 0. 0.6.6. 6 0 6 0 Overpressure [bar] 0. 0 0 0 0 0 80 80 0 Burst pressure [bar] 7.... 7. 7. 0 0 0 0 0 Vacuum resistance P N bar: unlimited vacuum resistance P N < bar: on request consider the pressure resistance of fitting and clamps Contact Number, type standard: PNP contact option: independent PNP contacts Max. switching current... 0 ma / and wire: contact rating ma, shortcircuit resistant; V switch = V S V 0... 0 V / wire: contact rating 00 ma, shortcircuit resistant Accuracy of contacts standard: nominal pressure < 0. bar: ± 0. % FSO nominal pressure 0. bar: ± 0. % FSO option : nominal pressure 0. bar: ± 0. % FSO Repeatability 0. % FSO Switching frequency wire: max. 0 Hz / wire: 0 Hz Switching cycles > 00 x 0 6 Delay time 0... 00 sec with ISprotection max. contact possible Analogue output (optionally) / Supply wire current signal... 0 ma / V S =... 6 V DC permissible load: R max = [(V S V S min) / 0.0 A] response time: < 0 msec wire current signal with ISprotection... 0 ma / V S =... 8 V DC permissible load: R max = [(V S V S min) / 0.0 A] response time: < 0 msec wire current signal... 0 ma / V S = V DC ± 0 % adjustable (turndown of span :) permissible load: R max = 00 response time: < 0 msec wire voltage signal 0 0 V / V S = V DC ± 0 % adjustable (turndown of span :) permissible load: R min = 0 k response time: < 0 msec Without analogue output V S =... 6 V DC Accuracy standard: nominal pressure < 0. bar: ± 0. % FSO nominal pressure 0. bar: ± 0. % FSO option : nominal pressure 0. bar: ± 0. % FSO accuracy according to IEC 60770 limit point adjustment (nonlinearity, hysteresis, repeatability) with turndown of span the analogue signal is adjusted automatically to the new measuring range Thermal errors (offset and span) / Permissible temperatures Nominal pressure P N [bar] 0 < 0.0 0.0 Tolerance band [% FSO] ± 0.7 ±. ± 0.7 in compensated range [ C] 0... 8 0... 0 0... 8 Permissible temperatures 6 medium: 0... C for filling fluid silicon oil 0... C for filling fluid food compatible oil electronics / environment: 0... 8 C storage: 0... 00 C Permissible temperature medium for cooling element 00 C filling fluid silicon oil overpressure: 0 00 C vacuum: 0... 0 C 7 filling fluid food compatible oil overpressure: 0... 0 C vacuum: 0... 0 C an optional cooling element can influence thermal effects for offset and span depending on installation position and filling conditions 6 max. temperature of the medium for nominal pressure gauge > 0 bar: 0 C for 60 minutes with a max. environmental temperature of 0 C 7 also for P abs < bar Electrical protection Shortcircuit protection Reverse polarity protection permanent no damage, but also no function Electromagnetic compatibility emission and immunity according to EN 66 Mechanical stability Vibration (DIN EN 600686) G /": 0 g RMS (... 000 Hz) others except G /": 0 g RMS ( 000 Hz) Shock (DIN EN 600687) G /": 00 g / msec others except G / : 00 g / msec Filling fluids Standard Optional silicon oil food compatible oil (with FDA approval) (Mobil DTE FM ; Category Code: H; NSF Registration No.: 066) others on request Materials Pressure port / Housing stainless steel.0 (6 L) others on request Viewing glass laminated safety glass Seals Standard Optional Diaphragm Media wetted parts FKM (recommended for medium temperatures 00 C) FFKM (recommended for medium temperatures > 00 C) Clamp, dairy pipe, Varivent : without stainless steel. (6L) pressure port, seal, diaphragm others on request

DS 00P Explosion protection (only for 0 ma / wire) Approval AXDS 00P Safety technical maximum values Max. switching current 8 Permissible temperatures for environment IBExU 06 ATEX 00 X Zone 0: II G Ex ia IIC T U i = 8 V, I i = 9 ma, P i = 660 mw, C 0 nf, L i 0 µh 70 ma in zone 0: 0... 60 C with p atm 0.8 bar up to. bar in zone :... 70 C Connecting cables (by factory) cable capacitance: signal line/shield also signal line/signal line: 00 pf/m cable inductance: signal line/shield also signal line/signal line: µh/m 8 the real switching current in the application depends on the power supply unit Miscellaneous Display Current consumption (without contacts) Ingress protection IP 67 Installation position Weight Operational life CEconformity Wiring diagrams wiresystem (current) p I supply + supply contact contact Pin configuration Electrical connection Designs 9 R VS Supply + Supply Signal + (only wire) Contact Contact Shield digit, 7segmentLED display, visible range 7. x mm; digit height 0 mm, range of indication 999... +9999; accuracy 0.% ± digit; digital damping 0. 0 sec (programmable); measured value update 0.0 0 sec (programmable) wire signal output current: wire signal output current: wire signal output voltage: max. ma approx. 0 ma + signal current approx. 0 ma any (standard calibration in a vertical position with the pressure port connection down; differing installation position for P N bar have to be specified in the order) min. 00 g (depending on mechanical connection) > 00 x 0 8 cycles EMC Directive: 00/08/EC wiresystem (current / voltage) p supply + supply signal + contact I/U contact A / V R VS Mx metal (pin) plug housing / pressure port Electrical connections (dimensions in mm) side display display (others on request) Mx (pin) 9 all designs in horizontal rotatable housing as standard www.bdsensors.com

DS 00P Mechanical connections (dimensions in mm) Standard Option G/" flush DIN 8 G /" flush DIN 8 (PN bar) Option G" flush DIN 8 G/" flush G" flush G" cone with radial oring with radial oring (PN bar) 70 70 Varivent dairy pipe (DIN 8) clamp (DIN 676) cooling element 00 C PN bar dimension in mm size DN DN 0 DN 0 A B 6 68. PN [bar] 0 0 dimension in mm size ¾ DN DN DN 0 A B 0. 0. 6 PN [bar] 8 6 6 6 metric threads and other versions on request

DS 00P Ordering Code DS 00P Pressure gauge absolute 7 A 7 A 6 Input [bar] 0.0 0 0 0 0.6 6 0 0 0. 0 0 0.0 0 0 0 0.60 6 0 0 0.0 0 0.6 6 0. 0.0 0 0 6.0 6 0 0 0 0 0 6 6 0 0 0 0 0 0 X 0 9 9 9 Design Stainless steel globe housing (side display) K H Stainless steel globe housing ( display) K consult Analogue output without 0 ma / wire 0 0 V / wire, adjustable 0 ma / wire, adjustable Intrinsic safety 0 ma / wire 0 7 E Contact contact contacts Accuracy standard for P N 0, bar 0. % standard for P N < 0, bar 0. % option for P N 0, bar 0. % Electrical connection Male plug Mx (pin) / metal version N 9 9 Mechanical connection G/" with flush welded diaphragm (DIN 8) Z 0 0 G/" with flush welded diaphragm (DIN 8) Z 0 G" with flush welded diaphragm (DIN 8) Z G" DIN 8 with rad. oring and flush diaphragm Z 7 G/" DIN 8 with rad. oring and flush diaphragm Z 6 G " cone Clamp DN (DIN 676) / A Clamp DN (DIN 676) / A Clamp DN 0 (DIN 676) / A Clamp /" (DIN 676) / A Dairy pipe DN (DIN 8) Dairy pipe DN 0 (DIN 8) Dairy pipe DN 0 (DIN 8) Varivent DN 0/0 / A K C 6 C 6 C 6 C 6 9 M 7 M 7 M 7 6 P 9 9 Diaphragm Stainless steel. (6L) Seals for clamp, dairy pipe, Varivent : none 0 for inch thread: FKM FFKM 7 consult Filling Fluids Silicon oil food compatible oil (FDA) Special version standard with cooling element up to 00 C 0 0 0 0 0 9 9 absolute pressure possible from bar with Ex version max. contact is possible only possible for nominal pressure ranges P N bar only possible for nominal pressure ranges P N bar The cup nut for dairy pipe has to be mounted by production of pressure transmitter. The cup nut has to be ordered as separate position. Varivent is a brand name of GEA Tuchenhagen GmbH Subject to change without notice.

Pressure switch with DIsPLAy DS 00P Electronic Pressure Switch Process Connections With Flush Welded Stainless Steel Diaphragm accuracy according to IEC 60770: standard: 0. % FSO option: 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 0 bar Contacts, or independent PNP contacts, freely configurable Analogue output wire:... 0 ma wire: 0 ma / 0 0 V others on request Special characteristics indication of measured values on a digit LED display rotatable and configurable display module configurable contacts (switch on/switch off points, hysteresis/window mode, switch on/switch off Optional versions ISversion Ex ia = intrinsically safe for gases The electronic pressure switch DS 00P is the successful combination of intelligent pressure switch digital display and is suitable for the usage with viscous and pasty media. As standard the DS 00P offers a PNP contact and a rotatable display module with digit LED display. Optional versions like e.g. an intrinsically safe version, max. contacts and an analogue output complete the profile. Preferred areas of use are Food and Beverage Pharmaceutical Industry Material and test certificates inspection certificate. according to EN 00 test report. according to EN 00 specific versions 70

DS 00P Input pressure range Nominal pressure (P N) gauge / abs. [bar]... 0 0.0 0.6 0. 0.0 0.60.6. 6 0 6 0 Overpressure [bar] 0. 0 0 0 0 0 80 80 0 Burst pressure [bar] 7.... 7. 7. 0 0 0 0 0 Vacuum resistance P N bar: unlimited vacuum resistance P N < bar: on request consider the pressure resistance of fitting and clamps Contact Standard PNP contact Options independent PNP contacts independent PNP contacts (possible with Mx, 8pin for... 0 ma/wire; 0... 0 V/wire on request) Max. switching current... 0 ma / and wire: contact rating ma, shortcircuit resistant; V Switch = V S V 0... 0 V / wire: contact rating 00 ma, shortcircuit resistant Accuracy of contacts standard: P N < 0. bar: ± 0. % FSO P N 0. bar: ± 0. % FSO option: P N 0. bar: ± 0. % FSO Repeatability 0. % FSO Switching frequency max. 0 Hz Switching cycles > 00 x 0 6 Delay time 0... 00 sec max. contact for wire current signal with plug ISO 00 as well as wire current signal with ISprotection no contact possible with wire in combination with plug ISO 00 accuracy according to IEC 60770 limit point adjustment (nonlinearity, hysteresis, repeatability) Analogue output (optionally) / Supply wire current signal... 0 ma / V S =... 6 V DC permissible load: R max = [(V S V S min) / 0.0 A] response time: < 0 msec wire current signal with ISprotection... 0 ma / V S =... 8 V DC permissible load: R max = [(V S V S min) / 0.0 A] response time: < 0 msec wire current signal... 0 ma / V S = 9... 0 V DC adjustable (turndown of span :) permissible load: R max = 00 response time: < 0. sec wire voltage signal 0 0 V / V S =... 6 V DC permissible load: R min = 0 k response time: < 0 msec Without analogue output V S =... 6 V DC Accuracy standard: P N < 0. bar: ± 0. % FSO P N 0. bar: ± 0. % FSO option: P N 0. bar: ± 0. % FSO with turndown of span the analogue signal is adjusted automatically to the new measuring range Thermal errors (Offset and Span) / Permissible temperatures Nominal pressure P N [bar] 0 < 0.0 0.0 Tolerance band [% FSO] ± 0.7 ±. ± 0.7 in compensated range [ C] 0... 8 0... 0 0... 8 Permissible temperatures 6 medium: 0... C for filling fluid silicon oil 0... C for filling fluid food compatible oil electronics / environment: 0... 8 C storage: 0... 00 C Permissible temperature medium filling fluid silicon oil overpressure: 0 00 C vacuum: 0... 0 C 7 for cooling element 00 C filling fluid food compatible oil overpressure: 0... 0 C vacuum: 0... 0 C an optional cooling element can influence thermal effects for offset and span depending on installation position and filling conditions. 6 max. temperature of the medium for nominal pressure gauge > 0 bar: 0 C for 60 minutes with a max. environmental temperature of 0 C 7 also for P abs < bar Electrical protection Shortcircuit protection permanent Reverse polarity protection no damage, but also no function Electromagnetic compatibility emission and immunity according to EN 66 Mechanical stability Vibration g RMS (... 000 Hz) according to DIN EN 600686 Shock 00 g / msec according to DIN EN 600687 Filling fluids Standard silicon oil Options food compatible oil (with FDA approval) (Mobil DTE FM ; Category Code: H; NSF Registration No.: 066) others on request Materials Pressure port / Housing stainless steel.0 (6 L) others on request Display housing PA 6.6, Polycarbonate Seals (media wetted) Standard FKM (recommended for medium temperatures 00 C) Option FFKM (recommended for medium temperatures > 00 C) others on request Clamp, dairy pipe, Varivent : without Diaphragm Standard stainless steel. (6 L) Option Hastelloy C76 (.89) Tantalum on request Media wetted parts pressure port, seal, diaphragm

6 DS 00P Explosion protection (only for 0 ma / wire) Approval AXDS 00P IBExU06ATEX00 X zone : II G Ex ia IIC T Gb (connector) / II G Ex ia IIB T Gb (cable) Safety technical maximum U values i = 8 V, I i = 9 ma, P i = 660 mw, C 0 nf, L i 0 µh Max. switching current 8 70 ma (max. permissible inductivity:.7 mh) Permissible temperatures for environment... 70 C Connecting cables (by factory) cable capacitance: signal line/shield also signal line/signal line: 00 pf/m cable inductance: signal line/shield also signal line/signal line: µh/m 8 the real switching current in the application depends on the power supply unit Miscellaneous Display digit, red 7segmentLED display, digit height 7 mm, range of indication 999... +9999; accuracy 0. % ± digit; digital damping 0. 0 sec (programmable); measured value update 0.0 0 sec (programmable) Current consumption wire signal output current: max. ma (without contacts) wire signal output current: approx. ma + signal current wire signal output voltage: approx. ma Ingress protection IP 6 Installation position any (standard calibration in a vertical position with the pressure port connection down; different installation position for P N bar have to be specified in the order) Weight Operational life CEconformity Wiring diagrams wiresystem (current) approx. 60... 0 g > 00 x 0 6 cycles EMC Directive: 00/08/EC wiresystem (current / voltage) p supply + p supply + VS VS supply A supply signal + contact A/V I contact contact I/U contact contact contact Pin configuration Electrical connection Supply + Supply Signal + (only wire) Contact Contact Contact Contact Shield Mx plastic (pin) via pressure port Electrical connections (dimensions in mm) Mx metal (pin) plug housing/ pressure port Mx plastic (8pin) 6 7 via pressure port ISO 00 ground contact Binder series 7 (pin) plug housing/ pressure port cable colours (DIN 700) wh (white) bn (brown) gn (green) gy (grey) pk (pink) ye/gn (yellow / green) cable outlet PVC Ø =.9mm cable outlet PUR Ø =.7mm Mx (pin) Mx (8pin) ISO 00 Binder series 7 (polig) cable outlet 7 7 different cable types and lengths available, permissible temperature depends on kind of cable; standard: m PVC cable (without ventilation tube, permissible temperature:... 70 C)

DS 00P 7 Mechanical connections (dimensions in mm) Standard Option G/" flush (PN bar) G/" flush Option G" flush G/" flush with G" flush with G" cone radial oring radial oring ( PN bar) 70 Varivent dairy pipe (DIN 8) clamp (DIN 676) cooling element 00 C PN bar dimension in mm size DN DN 0 DN 0 A B 6 68. PN [bar] 0 0 dimension in mm size ¾ DN DN DN 0 A B 0. 0. 6 PN [bar] 8 6 6 6 SIL and SILEx version: total length increases by 6. mm! metric threads and other versions on request

8 DS 00P Ordering Code Pressure Input DS 00P Analogue output without 0 ma / wire 0 0 V / wire 0 ma / wire, adjustable Intrinsic safety 0 ma / wire gauge absolute 7 8 7 8 6 [bar] 0.0 0 0 0 0.6 6 0 0 0. 0 0 0.0 0 0 0 0.60 6 0 0 0.0 0 0.6 6 0. 0.0 0 0 6.0 6 0 0 0 0 0 6 6 0 0 0 0 0 0 X 0 9 9 9 0 7 E Contact, contact, contacts contacts Accuracy standard for P N > 0, bar 0. % standard for P N 0, bar 0. % option for P N 0, bar 0. % Electrical connection Male plug Mx (pin) / plastic version N 0 Male plug Mx (8pin) / plastic version M 0 Male plug Mx (pin) / metal version N Male and female plug ISO 00 Male plug Binder series 7 (pin) Cable outlet incl. cable 0 0 0 0 T A 0 9 9 Mechanical connection G/" with flush welded diaphragm (DIN 8) Z 0 0 G/" with flush welded diaphragm (DIN 8) Z 0 G" with flush welded diaphragm (DIN 8) Z G" DIN 8 with rad. oring and flush diaphragm 6 Z 7 G/" DIN 8 with rad. oring and flush diaphragm Z 6 G " cone Clamp DN (DIN 676) / A Clamp DN (DIN 676) / A Clamp DN 0 (DIN 676) / A Clamp /" (DIN 676) / A 7 Dairy pipe DN (DIN 8) Dairy pipe DN 0 (DIN 8) 7 Dairy pipe DN 0 (DIN 8) 7 Varivent DN 0/0 / A K C 6 C 6 C 6 C 6 9 M 7 M 7 M 7 6 P 9 9 Diaphragm Stainless steel. (6L) Tantalum T consult Hastelloy C76 (.89) H Seals for clamp, dairy pipe, Varivent : without 0 for inch thread: FKM FFKM 7 Filling Fluids Silicon oil food compatible oil (FDA) Special version standard with cooling element up to 00 C with Ex version max. contact is possible with connector ISO 00 and output wire version only max. contact possible; with wire version no contact possible contacts and Mx, 8pin only possible in combination and together with... 0 ma/wire; 0... 0 V/wire on request standard: m PVC cable without ventilation tube (permissible temperature: 70 C), others on request possible only for P N bar 6 possible only for P N bar 7 The cup nut for dairy pipe has to be mounted by production of pressure transmitter. The cup nut has to be ordered as separate position. Subject to change without notice. 0 0 0 0 0 9 9

Pressure switch with DIsPLAy 9 DS 0P Electronic Pressure Switch Pressure Port With Flush Welded Stainless Steel Diaphragm accuracy according to IEC 60770: 0. % FSO Nominal pressure from 0... 60 bar up to 00 bar Contacts, or independent PNP contacts, freely configurable Analogue output wire:... 0 ma wire: 0 ma / 0 0 V others on request Special characteristics The electronic pressure switch DS 0P is the successful combination of intelligent pressure switch digital display and is designed for universal applications in the mechanical engineering and other industries where a flush stainless steel diaphragm is necessary. This can be the case, for example, with higher viscous or slightly contaminated fluids. For usage with higher media temperature optionally a cooling element up to 00 C is available. Preferred areas of use are indication of measured values on a digit LED display rotatable and configurable display module Plant and Machine Engineering Food Industry Optional versions ISversion Ex ia = intrinsically safe for gases cooling element up to 00 C specific versions Preferred used for Viscous and pasty media

0 DS 0P Input pressure ranges Nominal pressure gauge/abs. [bar] 60 00 60 0 00 Overpressure [bar] 00 00 00 00 600 Burst pressure [bar] 0 0 00 00 60 Contact Standard PNP contact Options independent PNP contacts independent PNP contacts (possible with Mx, 8pin for... 0 ma/wire; 0... 0 V/wire on request) Max. switching current... 0 ma / and wire: contact rating ma, shortcircuit resistant; V switch = V S V 0... 0 V / Leiter: contact rating 00 ma, shortcircuit resistant Accuracy of contacts 0. % FSO Repeatability 0. % FSO Switching frequency max. 0 Hz Switching cycles > 00 x 0 6 Delay time 0... 00 sec max. contact for wire current signal with plug ISO 00 as well as wire current signal with Exprotection no contact possible with wire in combination with plug ISO 00 accuracy according to IEC 60770 limit point adjustment (nonlinearity, hysteresis, repeatability) Analogue output (optionally) / Supply wire current signal... 0 ma / V S =... 6 V DC permissible load: R max = [(V S V S min) / 0.0 A] response time: < 0 msec wire current signal with... 0 ma / V S =... 8 V DC Exprotection permissible load: R max = [(V S V S min) / 0.0 A] response time: < 0 msec wire current signal... 0 ma / V S = 9... 0 V DC adjustable (turndown of span max. :) permissible load: R max = 00 response time: < 0. sec wire voltage signal 0... 0 V / V S =... 6 V DC permissible load: R min = 0 k response time: < 0 msec without analogue output V S =... 6 V DC accuracy 0. % FSO with turndown of span the analogue signal is adjusted automatically to the new measuring range Thermal error (offset and span) / Permissible temperatures Thermal error ± 0. % FSO / 0 K in compensated range 0... 8 C Permissible temperatures medium: 0... C for filling fluid silicon oil 0... C for filling fluid food compatible oil electronics / environment: 0... 8 C storage: 0... 00 C Permissible temperature filling fluid silicon oil overpressure: 0 00 C vacuum: 0... 0 C medium for cooling element 00 C filling fluid food compatible oil overpressure: 0... 0 C vacuum: 0... 0 C an optional cooling element can influence thermal effects for offset and span depending on installation position and filling conditions max. temperature of the medium for overpressure > 0 bar: 0 C for 60 minutes with a max. environmental temperature of 0 Electrical protection Shortcircuit protection permanent Reverse polarity protection no damage, but also no function Electromagnetic compatibility emission and immunity according to EN 66 Mechanical stability Vibration g RMS (... 000 Hz) according to DIN EN 600686 Shock 00 g / msec according to DIN EN 600687 Filling fluids Standard silicon oil Optional food compatible oil with FDA approval (Mobil DTE FM ; Category Code: H; NSF Registration No.: 066) others on request Materials Pressure port stainless steel.0 (6 L) Housing stainless steel.0 (6 L) Display housing PA 6.6, Polycarbonate Seals standard: FKM (for media temperature 00 C) option: FFKM 6 (for media temperature > 00 C) others on request Diaphragm stainless steel. Media wetted parts pressure port, seals, diaphragm 6 for pressure ranges P N

DS 0P Explosion protection (only for 0 ma / wire) Approval AXDS 0P IBExU06ATEX00 X zone : II G Ex ia IIC T Gb (connector) / II G Ex ia IIB T Gb (cable) Safety technical maximum values U i = 8 V, I i = 9 ma, P i = 660 mw, C 0 nf, L i 0 µh Max. switching current 7 70 ma (max. permissible inductivity:.7 mh) Max. temperatures for environment... 70 C Connecting cables cable capacitance: signal line/shield also signal line/signal line: 00 pf/m (by factory) cable inductance: signal line/shield also signal line/signal line: µh/m 7 the real switching current in the application depends on the power supply unit Miscellaneous Display digit, red 7segmentLED display, digit height 7 mm, range of indication 999... +9999; accuracy 0. % ± digit; digital damping 0. 0 sec (programmable); measured value update 0.0 0 sec (programmable) Current consumption wire signal output current: max. ma (without contacts) wire signal output current: approx. ma + signal current wire signal output voltage: approx. ma Ingress protection IP 6 Installation position any (standard calibration in a vertical position with the pressure port connection down) Weight min. 00 g (depending on mechanical connection) Operational life > 00 x 0 6 cycles CEconformity EMC Directive: 00/08/EC Pressure Equipment Directive: 97//EC (module A) 8 ATEX Directive 9/9/EC 8 This directive is only valid for devices with maximum permissible overpressure > 00 bar. Wiring diagrams wiresystem (current) wiresystem (current/voltage) p supply + p supply + VS I supply contact contact A V S I/U supply signal + contact contact contact contact A/V Pin configuration Electrical connection Supply + Supply Signal + (only for wire) Contact Contact Contact Contact Shield Mx plastic (pin) via pressure port Electrical connections (dimensions in mm) Mx metal (pin) plug housing/ pressure port Mx plastic (8pin) 6 7 via pressure port ISO 00 ground contact Binder series 7 (pin) plug housing/ pressure port cable colours (DIN 700) wh (white) bn (brown) gn (green) gy (grey) pk (pink) ye/gn (yellow/green) cable outlet PVC Ø =.9mm cable outlet PUR Ø =.7mm Mx (pin) Mx (8pin) ISO 00 Binder series 7 (pin) cable outlet 9 9 different cable types and lengths available, permissible temperature depends on kind of cable; standard: m PVC cable (without ventilation tube, permissible temperature:... 70 C) www.bdsensors.com

DS 0P Mechanical connection (dimensions in mm) Standard Optional G/" flush G/" flush G" flush Optional G" flush cooling element with radial oring 00 C 0 metric threads and other versions on request 0 for pressure ranges P N

DS 0P Ordering Code DS 0P Pressure gauge absolute 7 8 7 7 8 8 Input [bar] 60 6 0 0 00 0 0 60 6 0 0 0 00 0 0 9 9 9 Analogue output without 0 ma / wire 0 0 V / wire 0 ma / wire, adjustable Intrinsic safety 0 ma / wire 0 7 E Contact, contact, contacts contacts Accuracy 0. % Electrical connection Male plug Mx (pin) / plastic version N 0 Male plug Mx (8pin) / plastic version M 0 Male plug Mx (pin) / metal version N Male and female plug ISO 00 Male plug Binder series 7 (pin) Cable outlet incl. cable 0 0 0 0 T A 0 9 9 Mechanical connection G/" DIN 8 with flush diaphragm Z 0 0 G/" DIN 8 with flush diaphragm Z 0 G" DIN 8 with flush diaphragm Z G /" DIN 8 with rad. oring and flush diaphragm Z 6 9 9 Diaphragm Stainless steel. (6L) 9 Seals FKM FFKM 7 Filling Fluids Silicon oil food compatible oil Special version standard 6 with cooling element up to 00 C 0 0 0 0 0 9 9 with Ex version max. contact is possible with connector ISO 00 and output wire version only max. contact possible; with wire version no contact possible contacts and Mx, 8pin only possible in combination and together with... 0 ma/wire; 0... 0 V/wire on request standard: m PVC cable without ventilation tube (permissible temperature: 70 C), others on request possible for nominal pressure ranges P N 00 bar 6 cooling element up to 00 C not possible for pressure range P N > 60 bar Subject to change without notice.

Pressure switch with DIsPLAy DS 7 Pressure Switch with welded Stainless Steel Sensor Characteristics: accuracy according to IEC 60770: 0. % FSO nominal pressure ranges from 0 6 bar up to 0 600 bar analogue output and up to contacts display and housing rotatable suitable for oxygen applications Input pressure range Nominal pressure gauge [bar] 6 0 6 0 60 00 60 0 00 600 Overpressure (static) [bar] 70 0 0 0 0 700 00 00 Burst pressure [bar] 8 70 70 0 80 80 700 700 00 00 00 Vacuum resistance unlimited Contact standard PNP contact option max. independent PNP contact; analogue output Switching current standard: contact rating max. 00 ma, shortcircuit resistant Accuracy of switching points ±. % FSO Repeatability ± 0. % FSO Switching frequency max. 0 Hz Switching cycles > 00 x 0 6 Delay time 0... 00 sec Analogue output (optionally) / Supply wire current signal... 0 ma / V S = V DC ± 0 % Accuracy ± 0. % FSO Permissible load wire: R max = 00 Influence effects supply: 0.0 % FSO / 0 V load: 0.0 % FSO / k Measuring rate 0 Hz accuracy according to IEC 60770 limit point adjustment (nonlinearity, hysteresis, repeatability) Thermal effects (Offset and Span) / Permissible temperatures Thermal error ± 0. % FSO / 0 K in compensated range... 8 C Permissible temperatures medium:... C electronics / environment:... 8 C storage: 0... 8 C Electrical protection Shortcircuit protection permanent Reverse polarity protection no damage, but also no funcition Electromagnetic compatibility emission and immunity according to EN 66

DS 7 Mechanical stability Vibration 0 g ( 000 Hz) according to DIN EN 600686 Shock 00 g / msec according to DIN EN 600687 Materials Pressure port / Housing stainless steel.7 (6 Ti) / stainless steel.0 (0) Display housing PA 6.6, polycarbonate Seal sensor none (welded) Diaphragm stainless steel. (7PH) Media wetted parts pressure port, seal pressure port, diaphragm Miscellaneous Weight approx. 60 g Display digit, red LED display, digit height 7 mm, digit width.8 mm (angle 0 ); range of indication 999... +9999; accuracy 0.% ± digit; digital damping 0. 0 sec (programmable); measured value update 0.0 0 sec (programmable) Long term stability ± 0. % FSO / year at reference conditions CEconformity EMC Directive: 00/08/EC Pressure Equipment Directive: 97//EC (module A) This directive is only valid for devices with maximum permissible overpressure > 00 bar. Wiring diagrams wiresystem (current) p Supply + VS Supply Signal + A I Contact Contact Pin configuration Electrical connections supply + supply signal + (only for wire) contact contact shield Connections (dimensions in mm) Mx (pin) plastic via pressure port Mechanical connections optional Electronical connections G/" EN 87 Mx (pin) G/" EN 87 /" NPT

6 DS 7 Ordering Code DS 7 Pressure gauge 7 8 P Input [bar] 6 6 0 0 0 0 0 6 6 0 0 0 0 0 60 6 0 0 00 0 0 60 6 0 0 0 00 0 0 600 6 0 0 9 9 9 Analogue output without analogue output 0 ma / wire 0 7 Contact contact contacts Accuracy [IEC 60770] standard 0. % Electrical connection Male plug Mx (pin) / plastic version N 0 9 9 Mechanical connection G /" EN87 0 0 G/" EN 87 0 0 /" NPT N 0 9 9 9 Special version standard oxygen application 0 0 0 0 0 7 9 9 Subject to change without notice.

Pressure switch with DIsPLAy 7 DS 0 Electronic OEM Pressure Switch Applications: pneumatics pumps and hydraulic machines Characteristics: nominal pressure ranges from 0 bar up to 0 00 bar display and housing rotatable up to contacts configurable via display optional: analogue output Input pressure range Nominal pressure gauge [bar] 0 0 0 00 0 00 Overpressure [bar] 0 0 0 00 00 00 600 Burst pressure [bar] 7 70 0 0 0 60 Supply Supply voltage V S V DC ±0 % Current consumption < 0 ma (without analogue output and without contacts) Output signal Number, type standard: PNP contact optional: max. independent PNP contacts; analogue output Contact (Standard) Switching current standard: contact rating max. 00 ma, shortcircuit resistant Accuracy of contacts ±. % FSO BFSL Repeatability ± 0. % FSO BFSL Switching frequency max. 00 Hz Switching cycles > 00 x 0 6 Functions Hysteresis / Compare mode n/o / n/c Delay time 0... 99.99 sec Analogue output (optionally) Signal output... 0 ma (wire) Linearity, hysteresis, repeatability ± 0. % FSO BFSL Calibration accuracy ± % FSO BFSL Permissible load R max = 00 Response time < 0 msec depending on nominal pressure range Thermal effects (Offset and Span) / Permissible temperatures Thermal error for offset ± 0. % FSO / 0 K in compensated range... 8 C Permissible temperatures medium:... C electronics / environment:... 8 C storage: 0... 8 C

8 DS 0 Electrical protection Shortcircuit protection permanent Reverse polarity protection no damage, but also no function Electromagnetic compatibility emission and immunity according to EN 66 Materials Pressure port stainless steel.0 Housing stainless steel.0 Display housing PA 6.6, Polycarbonate Seals (media wetted) FKM others on request Diaphragm ceramic Al O 96 % Touchpad polyester Media wetted parts pressure port, seals, diaphragm Miscellaneous Display digit, red LED display, digit size 7 mm, digit width.8 mm (angle 0 ); range of indication 999... 9999; accuracy 0. % ± digit; digital damping 0. 0 sec (programmable); measured value update 0.0 0 sec (programmable) approx. 80 g any Weight Installation position Ingress protection IP 6 CEconformity EMC Directive: 00/08/EC Pressure Equipment Directive: 97//EC (module A) This directive is only valid for devices with maximum permissible overpressure > 00 bar Wiring diagram p Supply + VS Supply Signal + A I Contact Contact Pin configuration Electrical connection Dimensions (in mm) Supply + Supply Signal + Contact Contact Shield Mx (pin), plastic via pressure port G/" DIN 8 /" NPT

DS 0 Ordering Code 9 DS 0 Pressure gauge 7 8 R Input [bar] 0 0 0 0 0 0 0 0 0 0 0 0 0 00 0 0 0 0 00 0 0 9 9 9 Analogue output without analogue output 0 ma / wire 0 7 Contact contact contacts Calibration accuracy % G Electrical connection Male plug Mx (pin) / plastic version N 0 9 9 Mechanical connection G/" DIN 8 /" NPT 0 0 N 0 9 9 Seals FKM Special version standard 0 0 0 9 9 Subject to change without notice.

60 Pressure switch without DIsPLAy DS Electronic OEM Pressure Switch Pneumatics Applications: Pneumatics Vacuum technology Characteristics: nominal pressure ranges from 0... bar up to 0... 0 bar also... 0 bar or contacts compact design configurable via PC or programming device P6 Input pressure range Nominal pressure gauge [bar]... 0. 0 Overpressure [bar] 7 Supply Supply voltage V S... 0 V DC Current consumption max. ma (without contacts) Output signal Contact Number standard: optional: Type PNP Switching performance max. 00 ma, shortcircuit proof Accuracy of contacts ± % FSO Repeatability ± 0. % FSO Status indication SP : green SP : yellow Switching function standard: n/o optional: n/c Switching mode standard: hysteresis mode optional: window mode Switch on point standard: factory setting 80 % FSO others: specify on order; adjustable range 0... 00 % FSO Switch off point standard: factory setting 7 % FSO others: specify on order; adjustable range 0... 00 % FSO Switch on / switch off delay standard: off others: specify on order, adjustable range from 0 msec up to 90 sec (step 0 msec) Switching frequency 00 Hz (without switching delay) Switching cycles > 00 x 0 6 Analogue output (optionally) Analogue output... V / wire Accuracy IEC 60770 : % FSO Permissible load R min = 0 k with optional analogue output max. contact possible accuracy according to IEC 60770 limit point adjustment (nonlinearity, hysteresis, repeatability) Parameters can be programmed by either with the programming kit CIS 680 / CIS 68 or with the programming device P6 (available as accessories).

DS 6 Thermal effects (Offset and Span) / Permissible temperatures Tolerance band ± % FSO in compensated range 0... 0 C TC, average ± 0. % FSO / 0 K in compensated range 0... 0 C Permissible temperatures medium / electronics / environment:... 8 C storage: 0... 8 C Electrical protection Shortcircuit protection permanent Reverse polarity protection no damage, but also no function Electromagnetic compatibility emission and immunity according to EN 66 Mechanical stability Vibration 0 g RMS (0... 000 Hz) Shock 00 g / msec Materials Pressure port aluminium Housing PA 6.6 black Seal (media wetted) NBR Sensor silicon, RTV Media wetted parts pressure port, seal, sensor Miscellaneous Media compressed air, nonaggressive gases Weight approx. bis g Installation position any Ingress protection IP CEconformity EMC Directive: 00/08/EC Wiring diagrams contact (without analogue output) contacts (without analogue output) contact (with analogue output) supply + supply + supply + VS VS VS supply contact R supply contact contact R R supply signal + contact R Pin configuration Electrical connection Dimensions (in mm) Supply + Supply Signal + Contact Contact M8x (pin) contact M8x (pin) contacts M8x (pin) contact, analogue output Mechanical connections (view X) G/86. deep G/8" internal thread M7 deep view X M internal thread